Owner’s Manual

Digital Depth Sounder

g

with Dual Temperature (Flush Mounted, Remotely Switched)

  • Digital Depth Sounder displays depth in feet and meters
  • Shallow and Deep Water alarms
  • Alarms are Audio and Visual
  • Programmable Keel Offset

IS0246 rev. A ecr# 6875 4/2007

Page 2 of the Faria Instruments IS0246 user manual — Owner’s Manual
Page 2 · click to enlarge
Page 2
Faria Instruments IS0246 — Owner’s Manual diagram (page 2)
Fig. 5 · Owner’s Manual
Page 3 of the Faria Instruments IS0246 user manual — Owner’s Manual
Page 3 · click to enlarge
Page 3

positive terminal.

12. Connect a black wire (ground) to each of the switch negative terminals.
13. Once the transducer is installed and you have lead the cable to the depth sounder, connect the three wires (black, blue, and bare) from the transducer to the corresponding colored wires of the connector plug using the butt connectors supplied. (See Illustration)
1. It is recommended that insulated wire terminals, preferably ring type, be used on all connections to the power source.

The butt connectors have a heat activated waterproofing. When the butt connections have been crimped, slowly apply heat with a heat gun until you see sealant coming out of the connector ends. It is recommended to wrap the connections together with electrical tape for further protection. Plug the connector into the rear of the depth sounder.

2. Connect any one of the black wires to the boat’s electrical ground, usually available at several locations near the instrument panel.
3. Connect the purple wire to a 12 Volt DC circuit that is activated by the ignition switch.

2.) If the transducer cable is not connected properly or not plugged into the depth sounder, or the boat is not in the water, the display will blink when the power is applied to the unit.

4. Connect a second black wire to the water temperature sensor ground.
5. Connect the white wire to the water temperature white sensor signal wire.

3.) (If not part of the Transducer) Mount the Water temperature sensor as low as possible on the transom.

6. Connect a third black wire to the air temperature sensor ground

4.) Mount the Air temperature sensor anywhere in the boat other than the engine compartment. For best results place sensor away from direct sun light.

7. Connect the red wire to the air temperature white sensor signal wire.
8. Follow the enclosed instructions for installing the transducer with the adhesive supplied.

General description: 1. The depth sounder will display depth of 3 feet to 199 feet. If the reading is less than 19.9 feet, 1/10th increments will be displayed. If the reading is more than 19.9 feet, all readings will be in whole numbers.

9. Connect the blue wire to the “Mode” switch positive terminal.
10. Connect the green wire to the “Down” switch positive terminal.
2. The depth sounder has an audible and LCD displayed depth alarm with adjustable
11. Connect the grey wire to the “Up” switch
Page 4 of the Faria Instruments IS0246 user manual — Owner’s Manual
Page 4 · click to enlarge
Page 4

shallow and deep limits and a depth below keel offset feature. These settings once made are stored in memory and will remain even if the battery is disconnected.

zero. Pressing the “Mode” switch temporarily deactivates the alarm. To reactivate the alarm press the “Mode” switch until the depth reading appears.

Operation: 1. Power on. The depth sounder will activate automatically when the power to it is initially turned on. You do not have to press any key. The LCD will illuminate showing the depth in the upper display. The lower display will show a “W” and water temperature.

3. Keel offset. Pressing the “Mode” switch again displays the “KEEL,” keel offset setting. This can be set so that the depth sounder either shows the depth below the keel or the depth below the transducer.

Press the up or down arrow switches to adjust the reading to the desired depth no more than 19.9 ft.

Press the “Up” switch and the lower display will change to an “A” and the air temperature will be displayed.

For example if the bottom of the keel is 2.5 feet below the transducer and you want the depth sounder to read the depth below the keel, the display should be adjusted to read 2.5 FT.

Press the “Down” switch to return to the water temperature display.To turn the depth sounder off, press and hold the “Mode” switch for 4 seconds. Pressing the “Mode” switch again will reactivate the unit.

Units: Change the unit of measure. The lower display will show “UNIT” and the upper display will show either “US” or “EURO” for metric units. Pressing the up or down switches will cycle through the choices.

2. Depth alarm. Deep mode: Pressing the “Mode” switch again displays the “DEEP”, deep depth alarm setting. This is the deepest water that will activate the alarm. Press and hold the “Up” or the “Down” switch to adjust the reading to the desired depth.

Pressing the “Mode” switch will save the units shown in the display and change the display

Shallow mode: Press the “Mode” switch to display the “SHAL”, shallow depth alarm setting. This is the shallowest water that will activate the alarm. Press and hold the “Up” or the “Down” switch to adjust the reading to the desired depth.

Back to the normal depth mode. There will be no units shown in the displays. It will be up to the operator to determine the units from the temperature reading.

When the depth of the water is less than the shallow depth alarm setting the audible alarm will sound rapidly. When the depth of the water is deeper than the deep depth alarm setting the audible alarm will sound at 2 beeps per second.

Page 5 of the Faria Instruments IS0246 user manual — Owner’s Manual
Page 5 · click to enlarge
Page 5
Faria Instruments IS0246 — Owner’s Manual diagram (page 5)
Fig. 6 · Owner’s Manual

Press and Hold the “Mode” switch for 4 seconds to turn off the Depth Sounder.

Faria Instruments IS0246 — Owner’s Manual diagram (page 5)
Fig. 7 · Owner’s Manual

Quick Press the “Mode” switch to move between the screens.

Use the “Up” or “Down” switches to change settings.

(The Temperature will still display until Power Off.)

Use the “Up” or “Down” switches to set the Shallow Alarm depth.

Use the “Up” or “Down” switches to set the Deep Alarm depth.

Use the “Up” or “Down” switches to adjust the Keel Offset.

Use the “Up” or “Down” switches to change between unit types.

Display Sequence

Page 6 of the Faria Instruments IS0246 user manual — Owner’s Manual
Page 6 · click to enlarge
Page 6

Copyright 2007 by the Thomas G. Faria Corporation, Uncasville CT No part of this publication may be reproduced in any form, in an electronic retrieval system or otherwise, without the prior written permis sion of the company. Faria® is the trademark of the Thomas G. Faria Corporation

Ask about the Faria Instruments IS0246

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.