EN
Faria Instruments logo
Official user manual

Faria Instruments MG2000

32 pages·1.4 MB·Automobile Parts·PDF·ENDEFRITNLJA
Faria Instruments MG2000
Table of Contents 45 sections Owner’s Manual · GM ALDL MG2000 ™ Tachometer · IS0195 rev. A ecr#5576 8/2005 · Normal Mode · … ShowHide
Page 1 of the Faria Instruments MG2000 user manual — Owner’s Manual
Page 1 · click to enlarge
Page 1
Faria Instruments MG2000 — Owner’s Manual diagram (page 1)
Fig. 1 · Owner’s Manual

Owner’s Manual

GM ALDL MG2000 ™ Tachometer

IS0195 rev. A ecr#5576 8/2005

Page 2 of the Faria Instruments MG2000 user manual — Owner’s Manual
Page 2 · click to enlarge
Page 2

IS0195 x7 w/ corrections Mark ups 12/20/05

Page 3 of the Faria Instruments MG2000 user manual — Owner’s Manual
Page 3 · click to enlarge
Page 3

Index Figure 1 Default screens page 1 Description page 1 Normal Mode page 2 Contrast and Lighting page 2 Displayed Functions page 3 Default screen 1 page 3 Default screen 2 page 3 Default screen 3 page 3 Default screen 4 page 4 Figure 2 Screen Sequence page 4 Figure 3 LCD Display Screens page 5 Edit Mode page 7 Functions that are adjusted in Edit Mode. page 7 Select Default Screen page 7 Reset Fuel Used page 8 Set Fuel Tank Full page 8 Set Amount of Fuel page 9 Organize User Screens page 9 Select Gauge Range page 10 Select Oil Pressure Dial page 10 Select Coolant Temp Dial page 11 Select Voltmeter page 11 Select Water Press Dial page 12 Select Boost Press Dial page 12 Select Fuel Sender page 12 Select Oil Pressure Sender page 13 Select Display Units page 13 Select Pressure Units page 13 Select Volume Units page 14 Select Temperature Units page 14 Select Distance Units page 14 Select Depth Units page 15 Select Fuel Tank Size page 15 Select Other Fuel Tank Size page 15 Fuel Tank Calibration page 16 Low Fuel Alarm page 17 Software ID and Revision page 17 Select Self Test page 17 Alarm Mode page 19 Low Fuel page 19 Engine Warnings page 19 Alarm Messages From ECU page 20 Alarm Clear Mode page 21 Harness HN0390 page 22/23 Harness HN0401 GPS NMEA0183 Cable page 24 Harness Two inch Gauge connection page 25

Page 4 of the Faria Instruments MG2000 user manual — Owner’s Manual
Page 4 · click to enlarge
Page 4

This page left blank intentionally.

Page 5 of the Faria Instruments MG2000 user manual — Owner’s Manual
Page 5 · click to enlarge
Page 5

The FARIA MG2000 Tachometer combines the features of an ECU serial bus gateway and several instruments into one unit:

Faria Instruments MG2000 — Owner’s Manual diagram (page 5)
Fig. 2 · Owner’s Manual
  • The tachometer is analog in appearance but driven by a stepper motor for digital accuracy.
  • The high resolution LCD screen displays information for many other functions and the various “screens” can be configured as the user wishes. As received, the screens are configured as shown in Fig. 1.
Faria Instruments MG2000 — Owner’s Manual diagram (page 5)
Fig. 3 · Owner’s Manual

The MG2000 receives digital engine data from the Engine Control Unit (ECU) via the GM ALDL bus and can receive GPS information via a NMEA 0183 connection to a suitable GPS unit. GPS information is displayed in the MG2000 speedometer. Analog inputs are provided for two non- engine sensors such as fuel level and oil pressure.

Faria Instruments MG2000 — Owner’s Manual diagram (page 5)
Fig. 4 · Owner’s Manual

The MG2000 provides a Faria Bus output to allow use of various other 5, 4, and 2 inch instruments with the MG2000.

The Faria MG2000 Tachometer will turn on when the ignition key is turned on and will turn off when the ignition key is turned off. The unit will power up showing the default screen selected by the user.

The instrument has three push buttons; “M” “Mode”, “Down”, and “Up”; that control the functions available. The “M” “Mode” button is used to change the function of the LCD display and to access submenus and adjustable settings. The “Down” and “Up” buttons are used to modify the settings.

Faria Instruments MG2000 — Owner’s Manual diagram (page 5)
Fig. 5 · Owner’s Manual
Faria Instruments MG2000 — Owner’s Manual diagram (page 5)
Fig. 6 · Owner’s Manual
Faria Instruments MG2000 — Owner’s Manual diagram (page 5)
Fig. 7 · Owner’s Manual

In the “Normal” operation mode, pressing the “Mode” button and then pressing “Down” or “Up” button causes the display to cycle between the available screens

Default Screens

Page 6 of the Faria Instruments MG2000 user manual — Normal Mode
Page 6 · click to enlarge
Page 6

(see Figure 2). Press the “Mode” button to exit the “screen selection mode” and return to “Normal” mode or do not push any buttons for 4 seconds and the current screen will stay selected and the unit will return to “Normal” mode (see Figure 3).

Normal Mode

When the MG2000 is turned on the unit will “beep” once, flash once and then the unit enters “Self Test” mode. The screen will display “The Self Test Mode Is In Operation” for 10 seconds.

In the “Normal” operation mode, press the “Mode” and “Up” buttons to change to the “Edit” menus (see Figure 3 and “Edit” mode below).

Faria Instruments MG2000 — Normal Mode diagram (page 6)
Fig. 8 · Normal Mode
Faria Instruments MG2000 — Normal Mode diagram (page 6)
Fig. 9 · Normal Mode

The horn will sound three times and the warning lights and back lights will flash three times. When this is complete, the software ID and revision screen will show for two seconds, then the user selected “Default” screen will appear.

Press the “Down” or “Up” buttons to cycle between the available “Edit” functions.

Faria Instruments MG2000 — Normal Mode diagram (page 6)
Fig. 10 · Normal Mode

In the “Normal“ operating mode the instrument display contrast and display mode can be adjusted by pressing the “Down” and “Up” buttons.

Press and hold the “Down” and “Up” buttons for two (2) secs to select an “Edit” function to change. Within each “Editing” function the “Down” or “Up” buttons select settings or sub-functions. Follow the instructions in the “Edit” mode section of this manual to save the new settings after you select / adjust them.

With the display in “Positive” mode, black on white, pressing the “Down” button decreases the contrast. Pressing the “Up” button increases contrast.

To exit the “Edit” mode after the edit is completed, press the “Mode” button to return to “Normal” mode.

Faria Instruments MG2000 — Normal Mode diagram (page 6)
Fig. 11 · Normal Mode

Continuing to press the “Up” button causes the display to reverse to the “Negative” mode, white on black. The contrast in this mode is controlled the same way as the “Positive” mode.

To return to “Positive” mode, continue to press the “Down” button until the display reverses.

Contrast and Lighting

Page 7 of the Faria Instruments MG2000 user manual — OIL PRESSURE
Page 7 · click to enlarge
Page 7

OIL PRESSURE

Analog input. Displays information from the analog oil pressure sender.

To adjust the lighting intensity of all of the instruments in the system, press and hold both the “Down” and “Up” buttons for 2 seconds. The lighting intensity may now be adjusted by using the “Down” or “Up” buttons.

Displays the quantity of fuel remaining in the fuel tank based on the original quantity of fuel in the tank when full and the amount of fuel used based on the GPH from the engine ECU and the time spent at each GPH. Fuel tank size and reset are available in the “Edit” mode.

Return to the “Normal” mode by pressing and holding both the “Down” and “Up” buttons for 2 seconds.

Displays the amount of fuel used since reset based on the GPH from the engine ECU and the time spent at each GPH.

The tachometer is a digital instrument with the appearance of an analog instrument. The tachometer receives data directly from the ECU so no settings are required for the dial range. A microprocessor controlled stepper motor moves the pointer to display engine revolutions per minute. Default Screen “1”

Displays the current, instantaneous, fuel flow in GPH.

Displays the coolant temperature received from the ECU. Dial range can be selected in the “Edit” function.

Displays system voltage as received from the ECU (Engine Control Unit).

Show 10 more labels / short text on this page
Default Screen “2” · Fuel Left · Displayed Functions · Fuel Used · Tachometer · Fuel Inst · Default Screen “3” · Engine Temp · Volts · Engine Hours
Page 8 of the Faria Instruments MG2000 user manual — OIL PRESSURE
Page 8 · click to enlarge
Page 8

Displays the Engine Hours data received from the engine ECU.

Faria Instruments MG2000 — OIL PRESSURE diagram (page 8)
Fig. 12

LCD Display Screens:

In “Normal” mode, press “Mode” once to enter screen “Select” mode, press “Up” or “Down” to move between screens. Press “Mode” once to return to “Normal” mode.

This screen displays fault conditions based on engine data received from the ECU or alarms based on internally set alarm points. Engine alarms from the ECU will be displayed as “Check Engine !”

Faria Instruments MG2000 — OIL PRESSURE diagram (page 8)
Fig. 13

or “Engine Emergency Stop !”.

Faria Instruments MG2000 — OIL PRESSURE diagram (page 8)
Fig. 14

Screen “4” Alarms (ONLY IF ALARMS ACTIVE)

Accessing the “View“ mode when the Alarm screen appears will allow more information to be displayed about the alarm if provided by the engine.

Internal alarm values can be set for “Low Fuel” and other functions. Alarms for these settings will appear as required.

Show 4 more labels / short text on this page
Default screen “4” · Screen “1” · Screen “2” · Screen “3”
Page 9 of the Faria Instruments MG2000 user manual — OIL PRESSURE
Page 9 · click to enlarge
Page 9
Faria Instruments MG2000 — OIL PRESSURE diagram (page 9)
Fig. 15
1. Select Default Screen 2. Reset Fuel Used 3. Set Fuel Tank Full 4. Set Amount of Fuel 5. Organize User Screens 6. Select Gauge Range 7. Select Fuel Sender 8. Select Oil Pressure Sender 9. Select Display Units 10. Select Fuel Tank Size 11. Fuel Tank Calibrate 12. Low Fuel Alarm 13. Software ID and Revision 14. Select Self Test
Page 10 of the Faria Instruments MG2000 user manual — OIL PRESSURE
Page 10 · click to enlarge
Page 10

This page left blank intentionally.

Page 11 of the Faria Instruments MG2000 user manual — Edit Mode
Page 11 · click to enlarge
Page 11

Edit Mode

Functions that are set or adjusted in the “Edit” mode:

The “Edit” mode is used to adjust or set the values of numerous functions and options in the MG2000. The procedure below specifies the steps to be taken in the “Edit” mode to adjust / set each option.

1. Select Default Screen
2. Reset Fuel Used
3. Set Fuel Tank Full
4. Set Amount of Fuel

To enter “Edit” mode, press the “Mode” and “Up” buttons while in “Normal” mode

5. Organize User Screens
6. Select Gauge Range
7. Select Fuel Sender
8. Select Oil Pressure Sender
9. Select Display Units
10. Select Fuel Tank Size

To return to “Normal” mode, press “Mode” button once while in “Edit” mode.

11. Fuel Tank Calibrate
12. Low Fuel Alarm
13. Software ID and Revision
14. Select Self Test
Instructions – FunctionLINEDISPLAY Select “Default Screen.”1Select Default Screen 2 3 Press and hold the “Up” and “Down” buttons for 2 seconds to select the “Default Screen.” Press “Up” or “Down” to select another function or “Mode” to return to “Normal” mode. (Display Screen 1 is the “Default” at first turn on.)1Display Screen 1 2 3 Press and hold the “Up” and “Down” buttons for 2 seconds to select screen 1 as the “Default Screen” and exit. Press “Up” or “Down” to select another screen.
Page 12 of the Faria Instruments MG2000 user manual — Edit Mode
Page 12 · click to enlarge
Page 12
1Display Next Screen 2 3 Press and hold the “Up” and “Down” buttons for 2 seconds to select this screen as the “default screen” and exit. Press “Up” or “Down” to select another screen. Repeat until desired “Default Screen” is selected. Press “Up” or “Down” to select another function or “Mode” to return to “Normal” mode. Reset “Fuel Used”1Reset Fuel Used 2 3 Press and hold the “Up” and “Down” buttons for 2 seconds to reset “Fuel Used” to zero (0). Press “Up” or “Down” to select another function or “Mode” to return to “Normal” mode. Set “Fuel Tank Full”1Set Fuel Tank Full 2 3 NOTE: In order to use the “Fuel Left” function, the owner must set this function when the fuel tank is filled or use the set current amount of fuel below. In addition, if “Set Fuel Tank Full” function is used, the “Fuel Tank Size” must be set correctly to the size of the fuel tank in this application. The computer will monitor fuel usage and calculate the fuel left in the tank. This function does not replace the fuel level function provided by the fuel sender and should be used with caution. Press and hold the “Up” and “Down” buttons for 2 seconds to set “Fuel Tank Full.” Automatically sets the fuel available to the tank size selected by the user and returns to “Edit” mode. Press “Up” or “Down” to select another function or “Mode” to return to “Normal” mode.
Page 13 of the Faria Instruments MG2000 user manual — XXX G
Page 13 · click to enlarge
Page 13

Set “Amount of Fuel”

Press and hold the “Up” and “Down” buttons for 2 seconds to select “Current Amount of Fuel.”

Press “Up” or “Down” to set the amount of fuel known to be in the fuel tank. Adjust until the displayed volume matches the known amount of fuel in the tank.

When the volume is correctly set, Press and hold the “Up” and “Down” buttons for 2 seconds to save and exit.

XXX G

Press and hold the “Up” and “Down” buttons for 2 seconds to select “Organize User Screens.”

Press “Up” or “Down” to select another function or “Mode” to return to “Normal” mode.

3 Press and hold the “Up” and “Down” buttons for 2 seconds to select “Organize Screen 1.”

Press “Up” or “Down” to select another screen or “Mode” to return to “Edit” mode.

Refer to the list of available functions in the ownerʼs manual. Press and hold “Up” or “Down” to select the number of the function to be displayed in screen 1, line 1.

Show 15 more labels / short text on this page
1 Set · Amount · Of Fuel · 1 Fuel · Amount · 1 Organize · Organize User Screens · User · Screens · 1 Set up · Organize Screen 1 · Screen · 1 Screen 1 · Line 1 · Item XX
Page 14 of the Faria Instruments MG2000 user manual — XXX G
Page 14 · click to enlarge
Page 14

Press and hold the “Up” and “Down” buttons for 2 seconds to save selection for Screen 1, line 1 and advance to Screen 1, line 2.

Press “Mode” to exit with no change made.

Refer to the list of available functions in the ownerʼs manual. Press and hold “Up” or “Down” to select the number of the function to be displayed in screen 1, line 2.

Press and hold the “Up” and “Down” buttons for 2 seconds to save selection for Screen 1, line 2 and advance to Screen 1, line 3.

Press “Mode” to exit with no change made.

Refer to the list of available functions in the ownerʼs manual. Press and hold “Up” or “Down” to select the number of the function to be displayed in screen 1, line 3.

Press and hold the “Up” and “Down” buttons for 2 seconds to save selection for Screen 1, line 3 and advance to view new screen 1.

Press “Mode” to exit with no change made.

Press and hold the “Up” and “Down” buttons for 2 seconds to save new Screen 1.

Press “Mode” to exit with no change made.

Repeat for remaining screens (2, 3, etc).

Press “Up” or “Down” to select another function or “Mode” to return to “Normal” mode.

Select “Gauge Range” (dial reading range)

Press and hold the “Up” and “Down” buttons for 2 seconds to select “Gauge Range.”

Press “Up” or “Down” to select another function.

Select “Oil Pressure Dial”

Show 13 more labels / short text on this page
1 Screen 1 · Line 2 · Item XX · 1 Screen 1 · Line 3 · Item XX · 1 Display · Customer’s · New screen 1 · Gauge · Range · Oil Pressure · Dial
Page 15 of the Faria Instruments MG2000 user manual — XXX G
Page 15 · click to enlarge
Page 15

Press and hold the “Up” and “Down” buttons for 2 seconds to select “Oil Pressure Dial.”

Press “Up” or “Down” to select another “Gauge Range.”

Press “Mode” to return to the “Edit” mode.

Press “Up” or “Down” to scroll through the selections.

1 > 60 psi

When the correct choice is next to the selection arrow, Press and hold the “Up” and “Down” buttons for 2 seconds to save the selection and return to “Gauge Range” selection

Select “Coolant Temperature Dial”

Press and hold the “Up” and “Down” buttons for 2 seconds to select “Coolant Temp Dial.”

Press “Up” or “Down” to select another “Gauge Range.”

Press “Mode” to return to the “Edit” mode. Press “Up” or “Down” to scroll through the selections.

1 > 60 –220 f

When the correct choice is next to the selection arrow, Press and hold the “Up” and “Down” buttons for 2 seconds to save the selection and return to “Gauge Range” selection.

100. 250 f 2

Press and hold the “Up” and “Down” buttons for 2 seconds to select “Voltmeter Dial.”

Press “Up” or “Down” to select another “Gauge Range.”

Press “Mode” to return to the “Edit” mode. Press “Up” or “Down” to scroll through the selections.

1 > 16 v

When the correct choice is next to the selection arrow, Press and hold the “Up” and “Down” buttons for 2 seconds to save the selection and return to “Gauge Range” selection.

Show 7 more labels / short text on this page
80 psi · 100 psi · Coolant Temp · Dial · Select “Voltmeter Dial” · Voltmeter · Dial
Page 16 of the Faria Instruments MG2000 user manual — > 30 PSI
Page 16 · click to enlarge
Page 16

Select “Water Press Dial”

Press and hold the “Up” and “Down” buttons for 2 seconds to select “Water Press Dial.”

Press “Up” or “Down” to select another “Gauge Range.”

Press “Mode” to return to the “Edit” mode. Press “Up” or “Down” to scroll through the selections.

1 > 30 PSI

When the correct choice is next to the selection arrow, Press and hold the “Up” and “Down” buttons for 2 seconds to save the selection and return to “Gauge Range” selection.

45 PSI

60 PSI

Select “Boost Press Dial”

Press and hold the “Up” and “Down” buttons for 2 seconds to select “Boost Press Dial.”

Press “Up” or “Down” to select another “Gauge Range.”

Press “Mode” to return to the “Edit” mode. Press “Up” or “Down” to scroll through the selections.

1 20 PSI

When the correct choice is next to the selection arrow, Press and hold the “Up” and “Down” buttons for 2 seconds to save the selection and return to “Gauge Range” selection.

> 30 PSI

50 PSI

70 PSI

Press and hold the “Up” and “Down” buttons for 2 seconds to select “Fuel Sender.”

Press “Up” or “Down” to select another function.

Show 7 more labels / short text on this page
Water Press · Dial · Boost Press · Dial · Select “Fuel Sender” · Fuel · Sender
Page 17 of the Faria Instruments MG2000 user manual — 80 PSI
Page 17 · click to enlarge
Page 17

1 > USA

Press “Up” or “Down” to scroll through the selections.

240. 33 ohm

When the correct choice is next to the selection arrow, Press and hold the “Up” and “Down” buttons for 2 seconds to save the selection and return to the “Edit” mode.

EU

10. 180 ohm

Press “Up” or “Down” to select another function or “Mode” to return to the “Normal” mode.

Select “Oil Pressure Sender”

Press and hold the “Up” and “Down” buttons for 2 seconds to select “Oil Pressure Sender.”

Press “Up” or “Down” to select another function.

Press “Up” or “Down” to scroll through the selections.

1 60 PSI

When the correct choice is next to the selection arrow, Press and hold the “Up” and “Down” buttons for 2 seconds to save the selection and return to the “Edit” mode.

80 PSI

100 PSI

Press “Up” or “Down” to select another function or “Mode” to return to the “Normal” mode.

Press and hold the “Up” and “Down” buttons for 2 seconds to select “Units.”

Press “Up” or “Down” to select another function.

Press and hold the “Up” and “Down” buttons for 2 seconds to select “Pressure Units.”

Press “Up” or “Down” to select another choice of “Units.”

Show 9 more labels / short text on this page
Centroid · Oil Pressure · Sender · Select “Display Units” · Display · Units · Select “Pressure Units” · Pressure · Units
Page 18 of the Faria Instruments MG2000 user manual — 1 > F
Page 18 · click to enlarge
Page 18

Press “Up” or “Down” to scroll through the selections.

1 > PSI

When the correct choice is next to the selection arrow, Press and hold the “Up” and “Down” buttons for 2 seconds to save the selection and return to select “Units.”

BAR 2

Press and hold the “Up” and “Down” buttons for 2 seconds to select “volume units”

Press “Up” or “Down” to select another choice of “Units”

Press “Up” or “Down” to scroll through the selections.

1 > GAL

When the correct choice is next to the selection arrow, Press and hold the “Up” and “Down” buttons for 2 seconds to save the selection and return to select “Units”

LITERS 2

Press and hold the “Up” and “Down” buttons for 2 seconds to select “Temperature Units.”

Press “Up” or “Down” to select another choice of “Units.”

Press “Up” or “Down” to scroll through the selections.

1 > F

When the correct choice is next to the selection arrow, Press and hold the “Up” and “Down” buttons for 2 seconds to save the selection and return to select “Units.”

Press and hold the “Up” and “Down” buttons for 2 seconds to select “Distance Units.”

Press “Up” or “Down” to select another choice of “Units.”

Show 9 more labels / short text on this page
Select “Volume Units” · Volume · Units · Select “Temperature Units” · Temperature · Units · Select “Distance Units” · Distance · Units
Page 19 of the Faria Instruments MG2000 user manual — 36 G
Page 19 · click to enlarge
Page 19

Press “Up” or “Down” to scroll through the selections.

When the correct choice is next to the selection arrow, Press and hold the “Up” and “Down” buttons for 2 seconds to save the selection and return to select “Units.”

NM

Press and hold the “Up” and “Down” buttons for 2 seconds to select “Depth Units”

Press “Up” or “Down” to select another choice of “Units.”

Press “Up” or “Down” to scroll through the selections.

When the correct choice is next to the selection arrow, Press and hold the “Up” and “Down” buttons for 2 seconds to save the selection and return to select “Units.”

Press “Up” or “Down” to select another function or “Mode” to return to “Normal” mode.

Select “Fuel Tank Size”

Press and hold the “Up” and “Down” buttons for 2 seconds to select “Fuel Tank Size”

Press “Up” or “Down” to select another function

4 Press “Up” or “Down” to scroll through the selections.

1 > 25 G

When the correct choice is next to the selection arrow, Press and hold the “Up” and “Down” buttons for 2 seconds to save the selection and return to select “Units”

36 G

40 G

50 G

55 G

80 G

120 G

Show 13 more labels / short text on this page
1 > Miles · kM · Select “Depth Units” · Depth · Units · 1 > Feet · Meters · Fathoms · Fuel Tank · Size · Standard · Fuel Tank · Size
Page 20 of the Faria Instruments MG2000 user manual — XXX G
Page 20 · click to enlarge
Page 20

If there is no tank size available in the list that matches your tank size, scroll to the next screen.

Press “Up” or “Down” to set the fuel tank size displayed on the screen to match your fuel tank size. Line 4 value will adjust.

When set, Press and hold the “Up” and “Down” buttons for 2 seconds to save and exit.

XXX G

Press “Up” or “Down” to select another function or “Mode” to return to “Normal” mode.

Select “Fuel Tank Calibration”

Press and hold the “Up” and “Down” buttons for 2 seconds to select “Fuel Tank Calibration.”

Press “Up” or “Down” to select another function.

Ensure that fuel tank is as empty as possible.

Press and hold the “Up” and “Down” buttons for 2 seconds to save “Empty” calibration and press “Down” to go to “Half” tank calibration.

Fill fuel tank half full.

Press and hold the “Up” and “Down” buttons for 2 seconds to save “1/2 tank” calibration and press “Down” to go to “Full” tank calibration.

Fill fuel tank completely full.

Show 17 more labels / short text on this page
Other · Fuel Tank · Size · Other · Fuel Tank · 1 Calibrate · Fuel · Tank · 1 Calibrate · Fuel Tank · Empty · 1 Calibrate · Fuel Tank · Half · 1 Calibrate · Fuel Tank · Full
Page 21 of the Faria Instruments MG2000 user manual — NM
Page 21 · click to enlarge
Page 21

Press and hold the “Up” and “Down” buttons for 2 seconds to save “Full Tank” calibration and exit.

Press “Up” or “Down” to select another function or “Mode” to return to “Normal” mode.

Select “Low Fuel Alarm” setting

Press and hold the “Up” and “Down” buttons for 2 seconds to select “Low Fuel Alarm.”

Press “Up” or “Down” to select another function.

Adjust low fuel alarm setting.

Press “Up” or “Down” to set desired “Low Fuel Alarm” setting. Line 3 value will adjust.

Press and hold the “Up” and “Down” buttons for 2 seconds to save “Low Fuel Alarm” and exit.

Press “Up” or “Down” to select another function or “Mode” to return to “Normal” mode.

Select “Software ID and Revision”

Press “Up” or “Down” to select another function or “Mode” to return to “Normal” mode.

Press and hold the “Up” and “Down” buttons for 2 seconds to select “Self Test.”

Press “Up” or “Down” to select another function.

Show 13 more labels / short text on this page
1 Low · Fuel · Alarm · 1 Low · Fuel · 1 Software Id · and · Revision · Minigateway · - Rev - · Select “Self Test” · Self · Test
Page 22 of the Faria Instruments MG2000 user manual — NM
Page 22 · click to enlarge
Page 22

This screen will display for 10 seconds.

The horn will sound three times.

The warning lights will flash three times.

The backlights will flash three times.

When “Self Test” is complete the unit will return to the “Edit” mode.

Press “Up” or “Down” to select another function or “Mode” to return to “Normal” mode.

Available Functions for Display in MG2000 ALDL Tachometer Screens

The functions listed below can be displayed in the user configurable screens. All of the functions may not be available in your installation. If a function is selected for display and that function does not appear on the screen, the function does not exist in this installation.

A function is selected for display by selecting “Organize User Screens” in “Edit” mode.

1. System voltage 2. Oil Pressure 3. Coolant temperature (Engine Temp) 4. Engine hours 5. Fuel remaining based on usage and tank volume when filled (Fuel Left) 6. Fuel used since last reset (Fuel Used) 7. Fuel consumption rate (Fuel Inst)
Show 6 more labels / short text on this page
1 The · Self · Test · Mode · Is in · Operation
Page 23 of the Faria Instruments MG2000 user manual — STOP ! 2 3
Page 23 · click to enlarge
Page 23

alarm will re-occur after a period of time to ensure that the user remembers the alarm condition.

The “Alarm” screen appears only if an alarm condition exists. The alarm condition may be a warning sent from the engine ECU or a “Local” alarm such as “Low Fuel”. When an alarm condition occurs, the “Alarm Screen” will appear and the screens described below will be displayed.

Once an alarm condition has been corrected, the alarm screen, horn, and warning lights will no longer be displayed.

The descriptions below also explain how to temporarily override the alarm screen and audible / visual warnings and return to “Normal” mode. In all cases, the

Alarm Mode LINE DISPLAY

The “Alarm” screen will appear if a local alarm or an engine alarm occurs. The local alarm is “Low Fuel”. Only two engine alarms appear automatically, “Check Engine” and “Engine Emergency Stop”. Follow the instructions provided to view more information about engine alarms.

LOW FUEL Displays “Low Fuel” warning. Red LED blinks. Horn “Beeps”.

Press “Mode” to turn off LED, silence alarm horn, and return to “Run” mode. Alarm will reactivate in 15 minutes but can continue to be deactivated as required.

ENGINE WARNINGS

1 CHECK ENGINE

Any engine alarm except “Engine Emergency Stop” Red LED blinks. Horn “Beeps.”

1 ENGINE EMERGENCY

“Engine Emergency Stop” alarm. Red LED on continuously. Horn on continuously.

STOP ! 2 3

Show 5 more labels / short text on this page
Alarm Mode · 1 Low · Fuel · ! · ! 2 3
Page 24 of the Faria Instruments MG2000 user manual — ENGINE WARNINGS
Page 24 · click to enlarge
Page 24
Faria Instruments MG2000 — ENGINE WARNINGS diagram (page 24)
Fig. 16

Press and hold “Up” and “Down” for 2 seconds to view alarm messages. Press “Mode” to silence alarm horn and return to “Run” mode. LED will continue to function as stated until engine alarm(s) is no longer sent by ECU.

Page 25 of the Faria Instruments MG2000 user manual — ENGINE WARNINGS
Page 25 · click to enlarge
Page 25
Faria Instruments MG2000 — ENGINE WARNINGS diagram (page 25)
Fig. 17

When an alarm condition is corrected or clears, the “Alarms Clear !” screen will appear for approximately one second. The original screen will then reappear. This ensures that the operator is aware that the condition has been corrected.

Page 26 of the Faria Instruments MG2000 user manual — ALDL Harness HN0390 ALDL Tachometer Cable
Page 26 · click to enlarge
Page 26

ALDL Harness HN0390 ALDL Tachometer Cable

Pin 1 Red Pin 2 White Pin 3 Green Pin 4 Black Pin 5 Violet Pin 6 Pink Pin 7 Blue/ White Pin 8 Not Used Pin 9 Not Used Pin 10 Green/ Black Pin 11 Black Pin 12 Tan/ Blue

1 2 3 4 5 6 7 8 9 10 11 12

Pin A Red Pin B White Pin C Green Pin D Black & Sheild

ALDL Data ALDL Ground ALDL (Shield)

Oil Press Sender Fuel Sender Ignition +14 Vdc Ground

Show 19 more labels / short text on this page
MG2000 Tachometer · 12- pin connector · 4- pin connector · Green/ Black · Not Used · Not Used · Heat Shrink Tubing · Tan/ Blue · Black · Blue/White · Black · Violet · Pink · Heat Shrink Tubing · Blue/White · Pink · Violet · Black · Wire Jacket
Page 27 of the Faria Instruments MG2000 user manual — FARIA
Page 27 · click to enlarge
Page 27

MG2000 Speedometer Harness HN0390 Speedometer Cable

Pin 1 Red Pin 2 White Pin 3 Green Pin 4 Black Pin 5 Not Used Pin 6 Tan/ Black Pin 7 Tan Pin 8 Not Used Pin 9 Not Used Pin 10 Not Used Pin 11 Not Used Pin 12 Not Used

1 2 3 4 5 6 7 8 9 10 11 12

Air Temp/ Paddlewheel sender

FARIA

Black & Shield (Ground)

Show 19 more labels / short text on this page
12- pin connector · Not Used · Not Used · Not Used · Not Used · Not Used · Not Used · Wire Jacket · Red (+V) · Tan · Green (Signal) · Tan/Black · Bare (Ground) · White (Thermister) · Not Used · Not Used · Brown (Thermister) · Water Temp Sender · White (Sender Signal)
Page 28 of the Faria Instruments MG2000 user manual — NMEA 0183-A
Page 28 · click to enlarge
Page 28

NMEA 2000 Harness HN0401 NMEA 0183 Cable

Pin 1 Not Used Pin 2 Not Used Pin 3 Red/ White Pin 4 Red/ Blue Pin 5 Not Used Pin 6 Not Used

Faria Instruments MG2000 — NMEA 2000 Harness HN0401 NMEA 0183 Cable diagram (page 28)
Fig. 18 · NMEA 2000 Harness HN0401 NMEA 0183 Cable

NMEA 0183-A

NMEA 0183-B

Not Used Not Used

*Note: 1) Cut off the connector at the end of the antenna cable 2) Cut off the following wires because they are not used: White, Yellow, Brown 3) Cut wires so that they are different lengths. This ensures they do not touch each other.

Show 14 more labels / short text on this page
MG2000 Tachometer · 6- pin connector · GPS100 Antenna · Red/ White · Red/ Blue · Heat Shrink Tubing · Red (Ignition) · Green (0183-A) · Shield (Ground) · Brown* · Not Used · White* · Ground · Yellow*
Page 29 of the Faria Instruments MG2000 user manual — PJ0018
Page 29 · click to enlarge
Page 29

Tachometer to 2” Gauge Connection

PJ0018

Pin A Red Pin B White Pin C Green Pin D Black & Sheild

HN0503 From Tachometer · 4- pin connector · 2" Gauges

Page 30 of the Faria Instruments MG2000 user manual — Notes:
Page 30 · click to enlarge
Page 30

Notes:

Page 31 of the Faria Instruments MG2000 user manual — Notes:
Page 31 · click to enlarge
Page 31
Page 31 of the Faria Instruments MG2000 user manual — Notes:
Page 32 of the Faria Instruments MG2000 user manual — Notes:
Page 32 · click to enlarge
Page 32

Copyright 2005 by the Thomas G. Faria Corporation, Uncasville CT. All rights reserved. No part of this publication may be reproduced in any form, in an electronic retrieval system or otherwise, without the prior written permission of the company. Faria® is the trademark of the Thomas G. Faria Corporation

Ask about the Faria Instruments MG2000

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Faria Instruments MG2000

Be the first to ask — other owners or our team will answer.

Original document

Faria Instruments MG2000 manual PDF

32 pages·1.4 MB·Automobile Parts·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…