Index Figure 1 Default screens page 1 Description page 1 Normal Mode page 2 Contrast and Lighting page 2 Displayed Functions page 3 Default screen 1 page 3 Default screen 2 page 3 Default screen 3 page 3 Default screen 4 page 4 Figure 2 Screen Sequence page 4 Figure 3 LCD Display Screens page 5 Edit Mode page 7 Functions that are adjusted in Edit Mode. page 7 Select Default Screen page 7 Reset Fuel Used page 8 Set Fuel Tank Full page 8 Set Amount of Fuel page 9 Organize User Screens page 9 Select Gauge Range page 10 Select Oil Pressure Dial page 10 Select Coolant Temp Dial page 11 Select Voltmeter page 11 Select Water Press Dial page 12 Select Boost Press Dial page 12 Select Fuel Sender page 12 Select Oil Pressure Sender page 13 Select Display Units page 13 Select Pressure Units page 13 Select Volume Units page 14 Select Temperature Units page 14 Select Distance Units page 14 Select Depth Units page 15 Select Fuel Tank Size page 15 Select Other Fuel Tank Size page 15 Fuel Tank Calibration page 16 Low Fuel Alarm page 17 Software ID and Revision page 17 Select Self Test page 17 Alarm Mode page 19 Low Fuel page 19 Engine Warnings page 19 Alarm Messages From ECU page 20 Alarm Clear Mode page 21 Harness HN0390 page 22/23 Harness HN0401 GPS NMEA0183 Cable page 24 Harness Two inch Gauge connection page 25

This page left blank intentionally.

The FARIA MG2000 Tachometer combines the features of an ECU serial bus gateway and several instruments into one unit:


The MG2000 receives digital engine data from the Engine Control Unit (ECU) via the GM ALDL bus and can receive GPS information via a NMEA 0183 connection to a suitable GPS unit. GPS information is displayed in the MG2000 speedometer. Analog inputs are provided for two non- engine sensors such as fuel level and oil pressure.

The MG2000 provides a Faria Bus output to allow use of various other 5, 4, and 2 inch instruments with the MG2000.
The Faria MG2000 Tachometer will turn on when the ignition key is turned on and will turn off when the ignition key is turned off. The unit will power up showing the default screen selected by the user.
The instrument has three push buttons; “M” “Mode”, “Down”, and “Up”; that control the functions available. The “M” “Mode” button is used to change the function of the LCD display and to access submenus and adjustable settings. The “Down” and “Up” buttons are used to modify the settings.



In the “Normal” operation mode, pressing the “Mode” button and then pressing “Down” or “Up” button causes the display to cycle between the available screens
Default Screens

(see Figure 2). Press the “Mode” button to exit the “screen selection mode” and return to “Normal” mode or do not push any buttons for 4 seconds and the current screen will stay selected and the unit will return to “Normal” mode (see Figure 3).
When the MG2000 is turned on the unit will “beep” once, flash once and then the unit enters “Self Test” mode. The screen will display “The Self Test Mode Is In Operation” for 10 seconds.
In the “Normal” operation mode, press the “Mode” and “Up” buttons to change to the “Edit” menus (see Figure 3 and “Edit” mode below).


The horn will sound three times and the warning lights and back lights will flash three times. When this is complete, the software ID and revision screen will show for two seconds, then the user selected “Default” screen will appear.
Press the “Down” or “Up” buttons to cycle between the available “Edit” functions.

In the “Normal“ operating mode the instrument display contrast and display mode can be adjusted by pressing the “Down” and “Up” buttons.
Press and hold the “Down” and “Up” buttons for two (2) secs to select an “Edit” function to change. Within each “Editing” function the “Down” or “Up” buttons select settings or sub-functions. Follow the instructions in the “Edit” mode section of this manual to save the new settings after you select / adjust them.
With the display in “Positive” mode, black on white, pressing the “Down” button decreases the contrast. Pressing the “Up” button increases contrast.
To exit the “Edit” mode after the edit is completed, press the “Mode” button to return to “Normal” mode.

Continuing to press the “Up” button causes the display to reverse to the “Negative” mode, white on black. The contrast in this mode is controlled the same way as the “Positive” mode.
To return to “Positive” mode, continue to press the “Down” button until the display reverses.
Contrast and Lighting

Analog input. Displays information from the analog oil pressure sender.
To adjust the lighting intensity of all of the instruments in the system, press and hold both the “Down” and “Up” buttons for 2 seconds. The lighting intensity may now be adjusted by using the “Down” or “Up” buttons.
Displays the quantity of fuel remaining in the fuel tank based on the original quantity of fuel in the tank when full and the amount of fuel used based on the GPH from the engine ECU and the time spent at each GPH. Fuel tank size and reset are available in the “Edit” mode.
Return to the “Normal” mode by pressing and holding both the “Down” and “Up” buttons for 2 seconds.
Displays the amount of fuel used since reset based on the GPH from the engine ECU and the time spent at each GPH.
The tachometer is a digital instrument with the appearance of an analog instrument. The tachometer receives data directly from the ECU so no settings are required for the dial range. A microprocessor controlled stepper motor moves the pointer to display engine revolutions per minute. Default Screen “1”
Displays the current, instantaneous, fuel flow in GPH.
Displays the coolant temperature received from the ECU. Dial range can be selected in the “Edit” function.
Displays system voltage as received from the ECU (Engine Control Unit).

Displays the Engine Hours data received from the engine ECU.

LCD Display Screens:
In “Normal” mode, press “Mode” once to enter screen “Select” mode, press “Up” or “Down” to move between screens. Press “Mode” once to return to “Normal” mode.
This screen displays fault conditions based on engine data received from the ECU or alarms based on internally set alarm points. Engine alarms from the ECU will be displayed as “Check Engine !”

or “Engine Emergency Stop !”.

Screen “4” Alarms (ONLY IF ALARMS ACTIVE)
Accessing the “View“ mode when the Alarm screen appears will allow more information to be displayed about the alarm if provided by the engine.
Internal alarm values can be set for “Low Fuel” and other functions. Alarms for these settings will appear as required.



This page left blank intentionally.

Functions that are set or adjusted in the “Edit” mode:
The “Edit” mode is used to adjust or set the values of numerous functions and options in the MG2000. The procedure below specifies the steps to be taken in the “Edit” mode to adjust / set each option.
To enter “Edit” mode, press the “Mode” and “Up” buttons while in “Normal” mode
To return to “Normal” mode, press “Mode” button once while in “Edit” mode.


Set “Amount of Fuel”
Press and hold the “Up” and “Down” buttons for 2 seconds to select “Current Amount of Fuel.”
Press “Up” or “Down” to set the amount of fuel known to be in the fuel tank. Adjust until the displayed volume matches the known amount of fuel in the tank.
When the volume is correctly set, Press and hold the “Up” and “Down” buttons for 2 seconds to save and exit.
Press and hold the “Up” and “Down” buttons for 2 seconds to select “Organize User Screens.”
Press “Up” or “Down” to select another function or “Mode” to return to “Normal” mode.
3 Press and hold the “Up” and “Down” buttons for 2 seconds to select “Organize Screen 1.”
Press “Up” or “Down” to select another screen or “Mode” to return to “Edit” mode.
Refer to the list of available functions in the ownerʼs manual. Press and hold “Up” or “Down” to select the number of the function to be displayed in screen 1, line 1.

Press and hold the “Up” and “Down” buttons for 2 seconds to save selection for Screen 1, line 1 and advance to Screen 1, line 2.
Press “Mode” to exit with no change made.
Refer to the list of available functions in the ownerʼs manual. Press and hold “Up” or “Down” to select the number of the function to be displayed in screen 1, line 2.
Press and hold the “Up” and “Down” buttons for 2 seconds to save selection for Screen 1, line 2 and advance to Screen 1, line 3.
Press “Mode” to exit with no change made.
Refer to the list of available functions in the ownerʼs manual. Press and hold “Up” or “Down” to select the number of the function to be displayed in screen 1, line 3.
Press and hold the “Up” and “Down” buttons for 2 seconds to save selection for Screen 1, line 3 and advance to view new screen 1.
Press “Mode” to exit with no change made.
Press and hold the “Up” and “Down” buttons for 2 seconds to save new Screen 1.
Press “Mode” to exit with no change made.
Repeat for remaining screens (2, 3, etc).
Press “Up” or “Down” to select another function or “Mode” to return to “Normal” mode.
Select “Gauge Range” (dial reading range)
Press and hold the “Up” and “Down” buttons for 2 seconds to select “Gauge Range.”
Press “Up” or “Down” to select another function.
Select “Oil Pressure Dial”

Press and hold the “Up” and “Down” buttons for 2 seconds to select “Oil Pressure Dial.”
Press “Up” or “Down” to select another “Gauge Range.”
Press “Mode” to return to the “Edit” mode.
Press “Up” or “Down” to scroll through the selections.
1 > 60 psi
When the correct choice is next to the selection arrow, Press and hold the “Up” and “Down” buttons for 2 seconds to save the selection and return to “Gauge Range” selection
Select “Coolant Temperature Dial”
Press and hold the “Up” and “Down” buttons for 2 seconds to select “Coolant Temp Dial.”
Press “Up” or “Down” to select another “Gauge Range.”
Press “Mode” to return to the “Edit” mode. Press “Up” or “Down” to scroll through the selections.
1 > 60 –220 f
When the correct choice is next to the selection arrow, Press and hold the “Up” and “Down” buttons for 2 seconds to save the selection and return to “Gauge Range” selection.
Press and hold the “Up” and “Down” buttons for 2 seconds to select “Voltmeter Dial.”
Press “Up” or “Down” to select another “Gauge Range.”
Press “Mode” to return to the “Edit” mode. Press “Up” or “Down” to scroll through the selections.
1 > 16 v
When the correct choice is next to the selection arrow, Press and hold the “Up” and “Down” buttons for 2 seconds to save the selection and return to “Gauge Range” selection.

Select “Water Press Dial”
Press and hold the “Up” and “Down” buttons for 2 seconds to select “Water Press Dial.”
Press “Up” or “Down” to select another “Gauge Range.”
Press “Mode” to return to the “Edit” mode. Press “Up” or “Down” to scroll through the selections.
When the correct choice is next to the selection arrow, Press and hold the “Up” and “Down” buttons for 2 seconds to save the selection and return to “Gauge Range” selection.
60 PSI
Select “Boost Press Dial”
Press and hold the “Up” and “Down” buttons for 2 seconds to select “Boost Press Dial.”
Press “Up” or “Down” to select another “Gauge Range.”
Press “Mode” to return to the “Edit” mode. Press “Up” or “Down” to scroll through the selections.
When the correct choice is next to the selection arrow, Press and hold the “Up” and “Down” buttons for 2 seconds to save the selection and return to “Gauge Range” selection.
50 PSI
70 PSI
Press and hold the “Up” and “Down” buttons for 2 seconds to select “Fuel Sender.”
Press “Up” or “Down” to select another function.

Press “Up” or “Down” to scroll through the selections.
When the correct choice is next to the selection arrow, Press and hold the “Up” and “Down” buttons for 2 seconds to save the selection and return to the “Edit” mode.
Press “Up” or “Down” to select another function or “Mode” to return to the “Normal” mode.
Select “Oil Pressure Sender”
Press and hold the “Up” and “Down” buttons for 2 seconds to select “Oil Pressure Sender.”
Press “Up” or “Down” to select another function.
Press “Up” or “Down” to scroll through the selections.
When the correct choice is next to the selection arrow, Press and hold the “Up” and “Down” buttons for 2 seconds to save the selection and return to the “Edit” mode.
100 PSI
Press “Up” or “Down” to select another function or “Mode” to return to the “Normal” mode.
Press and hold the “Up” and “Down” buttons for 2 seconds to select “Units.”
Press “Up” or “Down” to select another function.
Press and hold the “Up” and “Down” buttons for 2 seconds to select “Pressure Units.”
Press “Up” or “Down” to select another choice of “Units.”

Press “Up” or “Down” to scroll through the selections.
When the correct choice is next to the selection arrow, Press and hold the “Up” and “Down” buttons for 2 seconds to save the selection and return to select “Units.”
Press and hold the “Up” and “Down” buttons for 2 seconds to select “volume units”
Press “Up” or “Down” to select another choice of “Units”
Press “Up” or “Down” to scroll through the selections.
When the correct choice is next to the selection arrow, Press and hold the “Up” and “Down” buttons for 2 seconds to save the selection and return to select “Units”
Press and hold the “Up” and “Down” buttons for 2 seconds to select “Temperature Units.”
Press “Up” or “Down” to select another choice of “Units.”
Press “Up” or “Down” to scroll through the selections.
When the correct choice is next to the selection arrow, Press and hold the “Up” and “Down” buttons for 2 seconds to save the selection and return to select “Units.”
Press and hold the “Up” and “Down” buttons for 2 seconds to select “Distance Units.”
Press “Up” or “Down” to select another choice of “Units.”

Press “Up” or “Down” to scroll through the selections.
When the correct choice is next to the selection arrow, Press and hold the “Up” and “Down” buttons for 2 seconds to save the selection and return to select “Units.”
Press and hold the “Up” and “Down” buttons for 2 seconds to select “Depth Units”
Press “Up” or “Down” to select another choice of “Units.”
Press “Up” or “Down” to scroll through the selections.
When the correct choice is next to the selection arrow, Press and hold the “Up” and “Down” buttons for 2 seconds to save the selection and return to select “Units.”
Press “Up” or “Down” to select another function or “Mode” to return to “Normal” mode.
Select “Fuel Tank Size”
Press and hold the “Up” and “Down” buttons for 2 seconds to select “Fuel Tank Size”
Press “Up” or “Down” to select another function
4 Press “Up” or “Down” to scroll through the selections.
When the correct choice is next to the selection arrow, Press and hold the “Up” and “Down” buttons for 2 seconds to save the selection and return to select “Units”
40 G
50 G
55 G
80 G
120 G

If there is no tank size available in the list that matches your tank size, scroll to the next screen.
Press “Up” or “Down” to set the fuel tank size displayed on the screen to match your fuel tank size. Line 4 value will adjust.
When set, Press and hold the “Up” and “Down” buttons for 2 seconds to save and exit.
Press “Up” or “Down” to select another function or “Mode” to return to “Normal” mode.
Select “Fuel Tank Calibration”
Press and hold the “Up” and “Down” buttons for 2 seconds to select “Fuel Tank Calibration.”
Press “Up” or “Down” to select another function.
Ensure that fuel tank is as empty as possible.
Press and hold the “Up” and “Down” buttons for 2 seconds to save “Empty” calibration and press “Down” to go to “Half” tank calibration.
Fill fuel tank half full.
Press and hold the “Up” and “Down” buttons for 2 seconds to save “1/2 tank” calibration and press “Down” to go to “Full” tank calibration.
Fill fuel tank completely full.

Press and hold the “Up” and “Down” buttons for 2 seconds to save “Full Tank” calibration and exit.
Press “Up” or “Down” to select another function or “Mode” to return to “Normal” mode.
Select “Low Fuel Alarm” setting
Press and hold the “Up” and “Down” buttons for 2 seconds to select “Low Fuel Alarm.”
Press “Up” or “Down” to select another function.
Adjust low fuel alarm setting.
Press “Up” or “Down” to set desired “Low Fuel Alarm” setting. Line 3 value will adjust.
Press and hold the “Up” and “Down” buttons for 2 seconds to save “Low Fuel Alarm” and exit.
Press “Up” or “Down” to select another function or “Mode” to return to “Normal” mode.
Select “Software ID and Revision”
Press “Up” or “Down” to select another function or “Mode” to return to “Normal” mode.
Press and hold the “Up” and “Down” buttons for 2 seconds to select “Self Test.”
Press “Up” or “Down” to select another function.

This screen will display for 10 seconds.
The horn will sound three times.
The warning lights will flash three times.
The backlights will flash three times.
When “Self Test” is complete the unit will return to the “Edit” mode.
Press “Up” or “Down” to select another function or “Mode” to return to “Normal” mode.
Available Functions for Display in MG2000 ALDL Tachometer Screens
The functions listed below can be displayed in the user configurable screens. All of the functions may not be available in your installation. If a function is selected for display and that function does not appear on the screen, the function does not exist in this installation.
A function is selected for display by selecting “Organize User Screens” in “Edit” mode.

alarm will re-occur after a period of time to ensure that the user remembers the alarm condition.
The “Alarm” screen appears only if an alarm condition exists. The alarm condition may be a warning sent from the engine ECU or a “Local” alarm such as “Low Fuel”. When an alarm condition occurs, the “Alarm Screen” will appear and the screens described below will be displayed.
Once an alarm condition has been corrected, the alarm screen, horn, and warning lights will no longer be displayed.
The descriptions below also explain how to temporarily override the alarm screen and audible / visual warnings and return to “Normal” mode. In all cases, the
Alarm Mode LINE DISPLAY
The “Alarm” screen will appear if a local alarm or an engine alarm occurs. The local alarm is “Low Fuel”. Only two engine alarms appear automatically, “Check Engine” and “Engine Emergency Stop”. Follow the instructions provided to view more information about engine alarms.
LOW FUEL Displays “Low Fuel” warning. Red LED blinks. Horn “Beeps”.
Press “Mode” to turn off LED, silence alarm horn, and return to “Run” mode. Alarm will reactivate in 15 minutes but can continue to be deactivated as required.
1 CHECK ENGINE
Any engine alarm except “Engine Emergency Stop” Red LED blinks. Horn “Beeps.”
“Engine Emergency Stop” alarm. Red LED on continuously. Horn on continuously.


Press and hold “Up” and “Down” for 2 seconds to view alarm messages. Press “Mode” to silence alarm horn and return to “Run” mode. LED will continue to function as stated until engine alarm(s) is no longer sent by ECU.


When an alarm condition is corrected or clears, the “Alarms Clear !” screen will appear for approximately one second. The original screen will then reappear. This ensures that the operator is aware that the condition has been corrected.

Pin 1 Red Pin 2 White Pin 3 Green Pin 4 Black Pin 5 Violet Pin 6 Pink Pin 7 Blue/ White Pin 8 Not Used Pin 9 Not Used Pin 10 Green/ Black Pin 11 Black Pin 12 Tan/ Blue
1 2 3 4 5 6 7 8 9 10 11 12
Pin A Red Pin B White Pin C Green Pin D Black & Sheild
ALDL Data ALDL Ground ALDL (Shield)
Oil Press Sender Fuel Sender Ignition +14 Vdc Ground

Pin 1 Red Pin 2 White Pin 3 Green Pin 4 Black Pin 5 Not Used Pin 6 Tan/ Black Pin 7 Tan Pin 8 Not Used Pin 9 Not Used Pin 10 Not Used Pin 11 Not Used Pin 12 Not Used
1 2 3 4 5 6 7 8 9 10 11 12
Air Temp/ Paddlewheel sender
Black & Shield (Ground)

Pin 1 Not Used Pin 2 Not Used Pin 3 Red/ White Pin 4 Red/ Blue Pin 5 Not Used Pin 6 Not Used

NMEA 0183-B
Not Used Not Used
*Note: 1) Cut off the connector at the end of the antenna cable 2) Cut off the following wires because they are not used: White, Yellow, Brown 3) Cut wires so that they are different lengths. This ensures they do not touch each other.

Pin A Red Pin B White Pin C Green Pin D Black & Sheild
HN0503 From Tachometer · 4- pin connector · 2" Gauges




Copyright 2005 by the Thomas G. Faria Corporation, Uncasville CT. All rights reserved. No part of this publication may be reproduced in any form, in an electronic retrieval system or otherwise, without the prior written permission of the company. Faria® is the trademark of the Thomas G. Faria Corporation
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.