Commander

™

Tachometer/ Engine Hourmeter

Analog Tachometer Digitally displays Hours Engine Has Been Run Fuel Level Other Features if Available: Fuel Management Fuel Flow in GPH or LPH Total or Trip Fuel Used Low Fuel Alarm Calculates Fuel Remaining In Tank SystemCheck® with Fuel Management or Ambient Air/ Water Temperature

ISO128E ECR#4851 08/04 IS0128

Page 2 of the Faria Instruments Depth Sounder (Commander) user manual — Commander
Page 2 · click to enlarge
Page 2

Installation Smaller Connector Page 1 Larger Connector Page 1 Operations Lighting Page 2 Tachometer Page 2 Engine Running Only Hourmeter Page 2 Fuel Level Page 2 Other Features Page 3 Set-Up Mode Page 3 Tachometer Selection Page 4 Fuel Management Installation guide (Fuel Flow Transducer) Page 5 Fuel Flow Page 6 Units per Hour selection Page 6 Fuel Used Page 6 Reset Page 7 Calibrate Page 7 Total Fuel Used Page 7 Reset Page 7 Fuel Remaining Page 8 Adjust Fuel Remaining Page 8 Fuel Remaining Alarm Page 8 Fuel Level Page 9 Bombardier® SystemCheck® Discription Page 10 Engine Temperature Page 10 Oil Level Page 10 Oil Flow Four Stroke engine Page 10 Two Stroke engine Page 10 Check Engine Page 10 Operating Modes Self Test Page 10 Normal Mode Page 10 Diagnostic Mode Page 11 Ambient Air and Water Temperature Discription Page 12 Water Temperature Page 12 Air Temperature Page 12 Figure 1 Fuel Management LCD Display Modes Page 9 Figure 2 Air/Water LCD Display Modes Page 12 Figure 3 Tachometer Set-Up Page 14 Table 1 Tachometer Selecion Table Page 15 Table 2 Fuel Sender Selection Table Page 15 HN0355 Larger connection Air/Water Temp.Wire Diagram Page 13 HN0356 Smaller Socket Connection Wire Diagram Page 16 HN0354 Larger connection Fuel Management Wire Diagram Page 17 HN0358 SystemCheck Wire Diagram Page 18-19

Index

Page 3 of the Faria Instruments Depth Sounder (Commander) user manual — Commander
Page 3 · click to enlarge
Page 3
Faria Instruments Depth Sounder (Commander) — Commander diagram (page 3)
Fig. 3 · Commander

Large Plug Note: For wiring diagram for the Large Connector Plug see HN0354 SystemCheck HN0358 or HN0355 for Temperature senders. HN0372 for 5 inch Commanders.

This manual for 4 or 5 inch Commanders with 1) Tach/Hour/Fuel Flow. 2) Tach/Hour/SystemCheck®/Fuel Flow. 3) Tach/Hour/Ambient Air/Water Temperature.

out of the connector ends. It is recommended to wrap the connections together with electrical tape for further protection. 2. Small Connector Socket Tachometer with Fuel Flow Follow the wiring diagram at the end of this manual for wiring connections. HN0356. SystemCheck® connections can be found on HN0358. Tachometer with Ambient Air and Water Temperature. Follow the wiring diagram at the end of this manual for wiring connections. HN0355. 3. Large Connector Socket Tachometer with Fuel Flow Follow the wiring diagram at the end of this manual for wiring connections. HN0354. SystemCheck® connections can be found on HN0358. Tachometer with Ambient Air and Water Temperature. Follow the wiring diagram at the end of this manual for wiring connections. HN0355 or HN0372 for 5 inch Commanders..

Installation: CAUTION: Disconnect the battery during installation. Tighten nuts on the backclamp only slightly more than you can tighten with your fingers. Six inch- pounds of torque are sufficient. Over- tightening could result in damage to the instrument and may void your warranty.

1. Cut a 3-3/8” diameter hole in the dash and mount the gauge with the backclamp supplied.

Follow the enclosed instructions for installing the sender. Once the sender is installed and you have run the cables to the Commander, connect the wires from the sender to the corresponding Small or Large connectors as illustrated using the butt connectors supplied. The butt connectors have a heat activated waterproofing. Once the butt connections have been crimped slowly apply heat with a heat gun until you see sealant coming

Page 4 of the Faria Instruments Depth Sounder (Commander) user manual — Operation
Page 4 · click to enlarge
Page 4

Operation

Lighting In normal operating mode the instrument lighting can be adjusted by pressing the “Up” and “Down” buttons.

The Commander has three push buttons;

Faria Instruments Depth Sounder (Commander) — Operation diagram (page 4)
Fig. 4 · Operation

Tachometer The tachometer is a digital instrument with the appearance of an analog instrument. The tachometer is preset at the factory for an eight cylinder engine and a 6000 RPM dial. The setting for the tachometer can be changed in the Set-Up menu (see below).

These buttons control the modes of operation. The “Mode” button is used to change the function of the LCD display and to access sub menus and adjustable settings. The “Up” and “Down” buttons are used to modify the settings.

A microprocessor controlled stepper motor moves the pointer to display engine revolutions per minute using a linear dial

In normal operation mode, pressing the “Mode” button quickly causes the display to cycle between the different instrument displays. Pressing and holding the “Mode” button causes the display to change to the “settings” sub menus (see Figure 1).

Engine Running Only Hourmeter The Engine Hours display shows the number of hours the engine has been operated (Hr). The reading is based on a signal being received at the tachometer input to indicate that the engine is running.

When the settings menus have been selected, pressing the “Mode” button quickly causes the display to cycle through the setting options. Within each setting selection, pressing the “Up and “Down” buttons causes the affected setting to change. Note: The microprocessor will automatically record the new settings as you adjust them.

Faria Instruments Depth Sounder (Commander) — Operation diagram (page 4)
Fig. 5 · Operation

Units are displayed as:

Faria Instruments Depth Sounder (Commander) — Operation diagram (page 4)
Fig. 6 · Operation

When in a setting menu, pressing and holding the “Mode” button returns to the main function.

Fuel Level The Fuel Level display shows the amount

The Tachometer and Fuel Level functions have several values that can be adjusted to match your installed equipment. These rarely used settings are changed in the Set- Up Mode (see Set-Up Menu guide below).

Faria Instruments Depth Sounder (Commander) — Operation diagram (page 4)
Fig. 7 · Operation

Description

Page 5 of the Faria Instruments Depth Sounder (Commander) user manual — M Mode Button
Page 5 · click to enlarge
Page 5

of fuel in the fuel tank in percent of full (PC). The indication is based on the fuel level sender in the tank and operates

Setup Mode

Tachometer settings and the fuel level sender type can be changed using the Setup Mode (see Figure 2, Table 1, and Table 2). Use this option only if you have reason to believe that your settings are wrong. Setting an incorrect value in these menus can result in extremely inaccurate performance of the tachometer and fuel level sender.

Faria Instruments Depth Sounder (Commander) — Setup Mode diagram (page 5)
Fig. 8 · Setup Mode

similarly to a normal fuel gauge. There are no adjustments to this reading.

To access the Setup Mode, press and hold both the “Up” and “Down” buttons while turning on the instrument.

Other Features The Commander can have special features programmed in it at the Factory.

1. Fuel Management which includes, Fuel Flow, Fuel Used, Total Fuel Used, and Fuel Remaining.

The display will shows,

Faria Instruments Depth Sounder (Commander) — Setup Mode diagram (page 5)
Fig. 9 · Setup Mode
2. Ambient Air and Water Temperature.

This manual covers both. Refer to your boats owners manual for which feature have been installed.

Briefly pressing the “Mode” button will cycle through the menu items.

M Mode Button

The “Up” and “Down” buttons are used to modify the settings.

The microprocessor will automatically record the new settings as you change them.

Page 6 of the Faria Instruments Depth Sounder (Commander) user manual — M Mode Button
Page 6 · click to enlarge
Page 6

. Pressing and holding the “Mode” button sets the instrument to normal operation.

The “TAC 9VA” setting is normally used when a belt driven alternator supplies the tachometer signal OR when no other method of selecting the tachometer mode gives correct readings.

M Mode Button

A digital or mechanical reference tachometer is needed to use this option. When this option is selected, the “VARIABL” submenu is available.

Tachometer Selection Refer to Figure 3 and Table 1 for an explanation of each of the tachometer selections.

Faria Instruments Depth Sounder (Commander) — M Mode Button diagram (page 6)
Fig. 10 · M Mode Button

T SCALE- The “TAC 1” - “TAC 7” settings are normal engine tachometer settings based on different engine options found on most boats. Using “Up” and “Down” buttons, adjust the setting to match the engine in the boat as shown in Figure 3.

Connect the reference tachometer as required. Operate the engine at a convenient RPM as high as can be safely maintained.

Using the “Up” and “Down” buttons, adjust the number shown in the display to match the reference tachometer.

The “TAC 8TH” setting is normally used on diesel engines with a magnetic pick-up measuring the number of teeth on the flywheel of the engine. When this option is selected, the “TEETH” submenu is available.

The tachometer pointer should also match the reference tachometer.

Faria Instruments Depth Sounder (Commander) — M Mode Button diagram (page 6)
Fig. 11 · M Mode Button

SENDER Allows you to set the type of sender you are using. See Figure 3.

Using the “Up” and “Down” buttons, adjust the number shown in the “TEETH” display until the number matches the published number of flywheel teeth for the engine.

Set up is now complete.

Page 7 of the Faria Instruments Depth Sounder (Commander) user manual — Installation of the fuel flow transducer
Page 7 · click to enlarge
Page 7

Installation Guide for the fuel flow transducer

IMPORTANT Always install the Fuel Flow Transducer AFTER the primary filter. The primary filter must be a good quality water separator type with a minimum filtration of 30 microns or better. (10 or 2 micron. The lower the micron rating the finer the filtration) Failure to provide this level of filtration protection will result in inaccurate readings or total failure or damage to the transducer. If there is not a suitable length of hose after the primary filter, an in-line filter (30 micron or better) should be fitted before the Fuel Flow transducer. Damage due to insufficient filtration is not covered by warranty. If in doubt please consult your local Marine dealer for advice prior to installation.

Wiring Connection

Keep electrical and transducer cables away from alternator or other noise generating electrical cables.

Fuel Flow Signal (White) Fuel Flow DC output positive (Black)

Faria Instruments Depth Sounder (Commander) — Wiring Connection diagram (page 7)
Fig. 12 · Wiring Connection

Black Heat shrink tubing on shield

Installation of the fuel flow transducer

The fuel flow transducer is designed for installation in Coast Guard approved 3/8“ flexible fuel line. The transducer MUST be installed AFTER the main fuel filter. It should be located well away from any area where it will be effected by excessive heat or vibration from the engine. It is preferable to mount the transducer in a vertical position.

Drain all the fuel from the flexible fuel line. Cut the fuel line and using the fuel hose attaching clips provided install the transducer so that the FUEL IN side of the transducer connects to the fuel tank.

Common Shield · From Tank

Page 8 of the Faria Instruments Depth Sounder (Commander) user manual — Pressing and holding the “Mode” button M Mode Button
Page 8 · click to enlarge
Page 8

Fuel Management Functions

Fuel Flow “UNITS” Menu

Description The Faria Commander Tachometer/ Fuel Monitor/ Engine Hourmeter combines the features of several instruments into one unit. The LCD displays the information for the other instruments:

Faria Instruments Depth Sounder (Commander) — Fuel Management Functions diagram (page 8)
Fig. 13 · Fuel Management Functions

Pressing the “Up” and “Down” buttons will change the setting between GH and LH.

1. Fuel Flow - Displays current fuel usage in Gallons or Liters per hour.
2. Fuel Used - Displays fuel used since last reset (trip fuel meter).
3. Total Fuel Used - Displays fuel used since last reset (total fuel meter).
Faria Instruments Depth Sounder (Commander) — Fuel Management Functions diagram (page 8)
Fig. 14 · Fuel Management Functions
4. Fuel Remaining - Displays the fuel remaining since last set (based on fuel flow).
5. Fuel Level - Displays fuel level in fuel tank (based on level sender) in percent.
6. Engine Hours - Displays the number of hours the engine has been run.

Fuel Used The Fuel Used display shows the amount of fuel used since the gauge was reset.

Faria Instruments Depth Sounder (Commander) — Fuel Management Functions diagram (page 8)
Fig. 15 · Fuel Management Functions
Faria Instruments Depth Sounder (Commander) — Fuel Management Functions diagram (page 8)
Fig. 16 · Fuel Management Functions

The Fuel Flow display shows current fuel consumption in gallons per hour (G) or liters per hour (L).

The display is based on the fuel flow system and therefore filling the fuel tank will not disturb the reading. The Fuel Used gauge may be reset to zero and the Fuel Used and Fuel Flow system calibrated using the sub menus.

The fuel flow sensor can be calibrated if necessary using the Fuel Used “settings” menu (see Fuel Used description below). The units displayed may be changed using the submenu. Pressing and holding the “Mode” button causes the display to change to the “UNITS” submenu (see Figure 1).

Faria Instruments Depth Sounder (Commander) — Fuel Management Functions diagram (page 8)
Fig. 17 · Fuel Management Functions

Pressing and holding the “Mode” button M Mode Button

Fuel Flow

Page 9 of the Faria Instruments Depth Sounder (Commander) user manual — M Mode Button
Page 9 · click to enlarge
Page 9

causes the display to change to the “settings” submenu (see Figure 1).

M Mode Button

Fuel Used “Settings” Menu There are two items in the Fuel Used “Settings” Menu; Reset and Fuel Calibration. Briefly pressing the “Mode” button cycles through the menu items. The microprocessor will automatically record the new settings as you adjust them.

When the displayed quantity matches the amount of fuel you know you have used, calibration is complete.

Faria Instruments Depth Sounder (Commander) — M Mode Button diagram (page 9)
Fig. 18 · M Mode Button

M Mode Button

The Total Fuel Used display shows the amount of fuel used since the Total Fuel Used gauge was reset.

Faria Instruments Depth Sounder (Commander) — M Mode Button diagram (page 9)
Fig. 19 · M Mode Button
Faria Instruments Depth Sounder (Commander) — M Mode Button diagram (page 9)
Fig. 20 · M Mode Button

Pressing the “Up” and “Down” button resets the Fuel Used gauge to zero.

This gauge is useful for keeping track of fuel usage over a longer period of time or distance than the Fuel Used gauge. The display is based on the fuel flow system and therefore filling the fuel tank will not disturb the reading.

The Total Fuel Used gauge may be reset to zero using the submenu. Pressing and holding the “Mode” button causes the display to change to the “settings” submenu (see Figure 1).

Faria Instruments Depth Sounder (Commander) — M Mode Button diagram (page 9)
Fig. 21 · M Mode Button

M Mode Button

If you know “exactly” how much fuel you have used since the Fuel Used gauge was reset you can adjust the amount and therefore the Fuel Flow sensor calibration in this “setting” menu.

Total Fuel Used “Settings” Menu There is one item in the Fuel Used “Settings” Menu; Reset.

Pressing the “Up” or “Down” buttons changes the “amount of fuel used” display.

Total Fuel Used · Reset · Calibration

Page 10 of the Faria Instruments Depth Sounder (Commander) user manual — M Mode Button
Page 10 · click to enlarge
Page 10
Faria Instruments Depth Sounder (Commander) — Fuel Management Functions diagram (page 10)
Fig. 22 · Fuel Management Functions

M Mode Button

Fuel Remaining “Settings” Menu There are two items in the Fuel Remaining “Settings” Menu; Adjust Fuel Remaining and Fuel Remaining Alarm.

Pressing the “Up” or “Down” button resets the Total Fuel Used gauge to zero.

Briefly pressing the “Mode” button cycles through the menu items.

M Mode Button

The microprocessor will automatically record the new settings a you adjust them.

Faria Instruments Depth Sounder (Commander) — M Mode Button diagram (page 10)
Fig. 23 · M Mode Button

The Fuel Remaining display shows the amount of fuel remaining in G or L.

Faria Instruments Depth Sounder (Commander) — M Mode Button diagram (page 10)
Fig. 24 · M Mode Button
Faria Instruments Depth Sounder (Commander) — M Mode Button diagram (page 10)
Fig. 25 · M Mode Button

When you fill the fuel tank or add fuel, you make a reasonable (or “exact”) estimate of the amount of fuel you have. Using this menu item you can enter (adjust) the amount of fuel remaining to your known (or estimated) amount. Pressing the “Up” or “Down” buttons will change the indicated Fuel Remaining.

This display is based on your manually entered information (see Adjust Fuel Remaining below) and the accumulated Fuel Flow data since the gauge was adjusted. This information is not obtained from the fuel sender in the fuel tank and therefore is not affected by the boats position or angle as the fuel sender may be.

There is an alarm which may be set to warn of a low fuel condition. The amount of Fuel Remaining and the Fuel Remaining Alarm may be adjusted using the submenu. Pressing and holding the “Mode” button causes the display to change to the “settings” submenu (see Figure 1).

Faria Instruments Depth Sounder (Commander) — M Mode Button diagram (page 10)
Fig. 26 · M Mode Button
Show 4 more labels / short text on this page
Reset · Fuel Remaining · Adjust Fuel Remaining · Fuel Remaining Alarm
Page 11 of the Faria Instruments Depth Sounder (Commander) user manual — Fuel Management LCD Display Modes
Page 11 · click to enlarge
Page 11

This alarm may be set to warn you when there is only a certain amount of fuel remaining according to the Fuel Flow usage calculation. Pressing the “Up” or “Down” buttons will change the Fuel Remaining Alarm setting.

Faria Instruments Depth Sounder (Commander) — Fuel Management LCD Display Modes diagram (page 11)
Fig. 27 · Fuel Management LCD Display Modes

The Fuel Level display shows the amount of fuel in the fuel tank in percent of full (PC). The indication is based on the fuel level sender in the tank and operates similarly to a normal fuel gauge. There are no adjustments to this reading.

Fuel Management LCD Display Modes

Faria Instruments Depth Sounder (Commander) — Fuel Management LCD Display Modes diagram (page 11)
Fig. 28 · Fuel Management LCD Display Modes
Faria Instruments Depth Sounder (Commander) — Fuel Management LCD Display Modes diagram (page 11)
Fig. 29 · Fuel Management LCD Display Modes
Faria Instruments Depth Sounder (Commander) — Fuel Management LCD Display Modes diagram (page 11)
Fig. 30 · Fuel Management LCD Display Modes
Faria Instruments Depth Sounder (Commander) — Fuel Management LCD Display Modes diagram (page 11)
Fig. 31 · Fuel Management LCD Display Modes
Faria Instruments Depth Sounder (Commander) — Fuel Management LCD Display Modes diagram (page 11)
Fig. 32 · Fuel Management LCD Display Modes
Show 7 more labels / short text on this page
Fuel Level · Quick Press · Quick Press · Quick Press · Quick Press · Quick Press · Quick Press
Page 12 of the Faria Instruments Depth Sounder (Commander) user manual — Fuel Management LCD Display Modes
Page 12 · click to enlarge
Page 12

Bombardier® SystemCheck® Description The Bombardier SystemCheck is a system that monitors Evinrude® and Johnson® outboard engine sensors, providing clear audible and visual indications whenever a fault occurs.

Check Engine: For fuel injected engines, the EMU generates the warning based on several fault conditions. For non-injected V6 outboard engines, a vacuum sensor is fitted in the fuel line. This is used to detect a blocked fuel line or fuel filter. (Non- injected engines without the vacuum sensor will not display this function.) The warning will be displayed as “CHK ENG”.

The system monitors engine temperature, oil level, oil flow, oil pressure, and fuel restriction. In addition, the ECM (Engine Control Module) can activate a warning indication. Not all sensors are present on all engines.

Faria Instruments Depth Sounder (Commander) — Fuel Management LCD Display Modes diagram (page 12)
Fig. 33 · Fuel Management LCD Display Modes

For information about the wiring of the Commander to the SystemCheck harness can be found on HN0358 in this manual.

There are three operating modes for SystemCheck systems, self test, normal, and diagnostic.

Engine Temperature: The displayed warning is “ENG HOT”.

Faria Instruments Depth Sounder (Commander) — Fuel Management LCD Display Modes diagram (page 12)
Fig. 34 · Fuel Management LCD Display Modes

Self test: On power up (key on), a limited self-test is performed to inform the operator that the system is active. The test activates the audible alarm and all warning messages. During the self test, the audible alarm sounds for 1/4 second. At the same time, the unit begins displaying all of the warning messages. Each warning message is displayed for 1 second. When all four messages have been displayed, the self test is complete.

Oil level: The sensor is a mechanical float switch in the 2 cycle oil reservoir. The displayed warning is “LO OIL”.

Faria Instruments Depth Sounder (Commander) — Fuel Management LCD Display Modes diagram (page 12)
Fig. 35 · Fuel Management LCD Display Modes

Normal mode: This mode occurs when two conditions are met. The self test must be complete, and the engine must be running in excess of 200 R.P.M. In this mode, any fault detected will result in an audible and visual alarm. Both will commence simultaneously.

Oil Flow: Four stroke engine: An oil pressure switch is used. Two stroke engine: An oil flow sensor is used to detect oil flow out of the oil injection system. The warning will be displayed as “NO OIL”.

Faria Instruments Depth Sounder (Commander) — Fuel Management LCD Display Modes diagram (page 12)
Fig. 36 · Fuel Management LCD Display Modes

The audible alarm will sound for 10 seconds. The visual warning will be displayed for as long as the fault conditions exist.

Operating Modes

Page 13 of the Faria Instruments Depth Sounder (Commander) user manual — Fuel Management LCD Display Modes
Page 13 · click to enlarge
Page 13

If the engine stops running, but the key switch remains on, the unit will automatically go to “Diagnostic” mode. Diagnostic mode: Simple diagnostics can be done with the key on, engine off. The intent is to aid the service technician in troubleshooting wiring or sensor problems. It can also be used to verify a system when there is no engine on the boat. In this mode, the following assumptions are made:

1. The key switch is on.
2. There is no tachometer signal (the engine is not running).
3. When the key switch is turned on, the self-test will be performed as usual.

After the self test is completed, the technician can ground any sensor input lead. The system will immediately display the fault condition associated with that input. The audible alarm is not sounded in this mode. In the event of a wiring error, it would be possible for multiple inputs to be grounded. In that case, the unit will display the multiple messages.

Page 14 of the Faria Instruments Depth Sounder (Commander) user manual — LCD Display Modes
Page 14 · click to enlarge
Page 14

Ambient Air and Water Temperature

The probe must be mounted so as to be exposed to free air but preferably not in direct sunlight. There are no adjustments for this function.

Description The Faria Commander Tachometer/ Water- Air Temperature/ Fuel Level/ Engine Hourmeter combines the features of several instruments into one unit. The LCD displays the information for the other instruments:

Fuel Level See description above.

1. Water Temperature - Displays the current water temperature.

LCD Display Modes

2. Ambient Air Temperature - Displays shows current air temperature
Faria Instruments Depth Sounder (Commander) — LCD Display Modes diagram (page 14)
Fig. 37 · LCD Display Modes
3. Fuel Level - Displays fuel level in fuel tank (based on level sender) in percent.
4. Engine Hours - Displays the number of hours the engine has been run.
Faria Instruments Depth Sounder (Commander) — LCD Display Modes diagram (page 14)
Fig. 38 · LCD Display Modes

The Water Temperature display shows current water temperature based on a Faria supplied temperature probe. The probe must be mounted so as to always be submerged to the depth desired. There are no adjustments for this function.

Faria Instruments Depth Sounder (Commander) — LCD Display Modes diagram (page 14)
Fig. 39 · LCD Display Modes

The Air Temperature display shows current air temperature based on a Faria supplied temperature probe.

Quick Press · Water Temperature · Air Temperature

Page 15 of the Faria Instruments Depth Sounder (Commander) user manual — Ambient Air and Water Temperature
Page 15 · click to enlarge
Page 15

Harness HN0355/HN372 Large Connector Air/Water Temp.

Faria Instruments Depth Sounder (Commander) — Ambient Air and Water Temperature diagram (page 15)
Fig. 40 · Ambient Air and Water Temperature

Pin A Red Air Temperature Pin B Black Ground Pin C White Water Temperature Pin D Pink Fuel Tank Sensor

Pin E Plug Not Used Pin F Plug Not Used

(Sensor Signal)

Page 16 of the Faria Instruments Depth Sounder (Commander) user manual — Ambient Air and Water Temperature
Page 16 · click to enlarge
Page 16

Tachometer Full Scale Selection Refer to Figure 3 for an explanation of each of the tachometer full scale selections.

This is normally a factory setting that needs no adjustment. The setting adjusts the “full scale” operating range of the tachometer to match the dial on the instrument. Using the “Up” and “Down” buttons, adjust the setting to match the maximum reading on the tachometer dial, 4000, 6000, or 7000 RPM.

Fuel Level Sender Selection Refer to Figure 3 and Table 2 for an explanation of each of the fuel level sender selections. Using the “Up” and “Down” buttons, adjust the setting to match the fuel level sender installed in the fuel tank.

Faria Instruments Depth Sounder (Commander) — Ambient Air and Water Temperature diagram (page 16)
Fig. 41 · Ambient Air and Water Temperature

To exit the setup mode, press and hold the button.

Set-Up start screen , shows that setup mode has been entered.

adjusts Pointer RPM shown to match displayed calibration reference

Set-Up Mode

Page 17 of the Faria Instruments Depth Sounder (Commander) user manual — Ambient Air and Water Temperature
Page 17 · click to enlarge
Page 17
Faria Instruments Depth Sounder (Commander) — Ambient Air and Water Temperature diagram (page 17)
Fig. 42 · Ambient Air and Water Temperature
Faria Instruments Depth Sounder (Commander) — Ambient Air and Water Temperature diagram (page 17)
Fig. 43 · Ambient Air and Water Temperature
Faria Instruments Depth Sounder (Commander) — Ambient Air and Water Temperature diagram (page 17)
Fig. 44 · Ambient Air and Water Temperature

TAC 1 Two pulses per rev. (4 cylinder, 4 cycle gas engine) TAC 2 Three pulses per rev. (6 cylinder, 4 cycle gas engine) TAC 3 Four pulses per rev. (8 cylinder, 4 cycle gas engine) TAC 4 Five pulses per rev. (10 pole alternator on outboard engine) TAC 5 Six pulses per rev. (12 pole alternator on outboard engine) TAC 6 Eight pulses per rev. (Not Used) TAC 7 Ten pulses per rev. (20 pole alternator on outboard engine) TAC 8 TH Two to Two Hundred Fifty pulses per rev. TAC 9 VA Match reference calibration digital or mechanical tachometer

Fuel Sender Selection Table

US Standard United States fuel sender ( 240 – 33 Ohms ) EU Standard European fuel sender ( 10 – 180 Ohms )

Tachometer Selection Table · Table · Table 2

Page 18 of the Faria Instruments Depth Sounder (Commander) user manual — To Commander
Page 18 · click to enlarge
Page 18

Harness HN0356 Small Connector

To Commander

Faria Instruments Depth Sounder (Commander) — To Commander diagram (page 18)
Fig. 45 · To Commander

Pin A Purple +12 Ignition Power Pin B Purple +12 Ignition Power Pin C Black Ground Pin D Gray Tachometer Input

Black · (Ground)

Page 19 of the Faria Instruments Depth Sounder (Commander) user manual — To Commander
Page 19 · click to enlarge
Page 19

Harness HN0354 Large Connector

To Commander

Faria Instruments Depth Sounder (Commander) — To Commander diagram (page 19)
Fig. 46 · To Commander

Pin A Red Fuel Flow Power Pin B Green Sender Grounds Pin C White Fuel Flow Signal Pin D Pink Fuel Tank Level

(Sender Power)

Page 20 of the Faria Instruments Depth Sounder (Commander) user manual — ECR 2275 4/15/02
Page 20 · click to enlarge
Page 20

Harness HN0358 Small Connector SystemCheck® adaptor

Small connector (CN0082) To Small Connector Socket

Pin A Purple +14 Ignition Pin B Tan/Orange Check Engine Pin C Black Ground Pin D Gray Tachometer Signal

ECR 2275 4/15/02

Faria Instruments Depth Sounder (Commander) — ECR 2275 4/15/02 diagram (page 20)
Fig. 47
Faria Instruments Depth Sounder (Commander) — ECR 2275 4/15/02 diagram (page 20)
Fig. 48

1 7 6 5

8 2 3 4

SystemCheck® Harness Deutsch Connector

Pin 1 Purple +14 vDC Ignition Pin 2 Black Ground Pin 3 Gray Tachometer Signal Pin 4 Tan/Yellow No Oil Sensor Pin 5 Tan/Black Low Oil Sensor Pin 6 Tan Over Temperature Pin 7 Tan/Orange Lo Oil Sensor Pin 8 Not Used

ECR 2275 4/15/02

Show 9 more labels / short text on this page
SystemCheck® · Harness · Purple Not Used · Black · Tan/Orange · Gray · Tan · Tan/Yellow · Tan/Black
Page 21 of the Faria Instruments Depth Sounder (Commander) user manual — ECR 2275 4/15/02
Page 21 · click to enlarge
Page 21

Harness HN0358 Large connector SystemCheck®

Large connector (CN0083)

To Large Connector Socket

Pin A Red Fuel Transducer Power Pin B Tan Over Temperature Pin C White Fuel Transducer Signal Pin D Pink Fuel Tank Level Pin E Tan/Black Low Oil Sensor Pin F Tan/Yellow No Oil Sensor

ECR 2275 4/15/02

Tan/Black (Lo Oil Sensor)

Tan/Yellow (No Oil Sensor)

Faria Instruments Depth Sounder (Commander) — ECR 2275 4/15/02 diagram (page 21)
Fig. 49

(Fuel Flow Transducer Power)

(Fuel Flow Transducer Signal)

Pink (Fuel Tank Level)

(Fuel Flow Transducer Ground)

Show 6 more labels / short text on this page
Tan (Over Temperature) · Red Black · White White · Shield · Boat Ground · Fuel Flow Transducer
Page 22 of the Faria Instruments Depth Sounder (Commander) user manual — Harness HN0358 Large connector SystemCheck®
Page 22 · click to enlarge
Page 22

Copyright 2004 by the Thomas G. Faria Corporation, Uncasville CT No part of this publication may by reproduced in any form, in an electronic retrieval system or otherwise, without the prior written permission of the company. Faria® is the trademark of the Thomas G. Faria Corporation SystemCheck®, Evinrude®, Johnson®, and Bomardier® are trademarks of Bombardier Motor Corporation of America.

Ask about the Faria Instruments Depth Sounder (Commander)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Faria Instruments Depth Sounder (Commander)

Be the first to ask — other owners or our team will answer.

Original document

Faria Instruments Depth Sounder (Commander) manual PDF

22 pages·5.1 MB·Automobile Parts·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…