Table of Contents 36 sections Owner’s Manual · IS0250a ecr7106 9/2007 · TABLE OF CONTENTS · Part I: Introduction · … ShowHide
Page 1 of the Faria Instruments IS0250a user manual — Owner’s Manual
Page 1 · click to enlarge
Page 1
Faria Instruments IS0250a — Owner’s Manual diagram (page 1)
Fig. 1 · Owner’s Manual
Faria Instruments IS0250a — Owner’s Manual diagram (page 1)
Fig. 2 · Owner’s Manual
Faria Instruments IS0250a — Owner’s Manual diagram (page 1)
Fig. 3 · Owner’s Manual

Owner’s Manual

IS0250a ecr7106 9/2007

Page 2 of the Faria Instruments IS0250a user manual — Owner’s Manual
Page 2 · click to enlarge
Page 2
Page 2 of the Faria Instruments IS0250a user manual — Owner’s Manual
Page 5 of the Faria Instruments IS0250a user manual — Part I: Introduction
Page 5 · click to enlarge
Page 5

Part I: Introduction

Congratulations on the purchase of your Faria Antares unit. This owner’s manual contains very important information regarding the installation, setup, and operation of your Antares. To get the best results in operation and performance please take a few minutes to read this manual and get acquainted with the Faria Antares unit.

Faria Instruments IS0250a — Part I: Introduction diagram (page 5)
Fig. 4 · Part I: Introduction
Page 6 of the Faria Instruments IS0250a user manual — IMAGE 1.1
Page 6 · click to enlarge
Page 6
B1Escape Button

IMAGE 1.1

B2Navigation Pad (Up, Down, Left, Right Arrows)
B3Enter Button
B4Radio Button (optional)
B5Power Button

button to turn on your Antares. It will take about 5-7 seconds for the Antares to complete its start-up process.

To begin, simply press the

appears. Navigate through display and setup screens by pressing the up, down, left, or right arrows on the navigation pad (image 1.1, pg. 4). After familiarizing yourself with the Antares screens, please continue to read through your owner’s manual for detailed operating instructions.

Your Antares is ready to use when the Gauge 1 Screen

Screen Indicator Bar

Page 7 of the Faria Instruments IS0250a user manual — MENU SCREEN
Page 7 · click to enlarge
Page 7

BUTTON FUNCTIONS

(B1): Returns to previous page when in menu / setup / radio control screens, silences alarms (B2): Use to change screens, scroll menu options, adjust settings

( B3)Select highlighted item
(B4)Activates radio control screen (not available on all Antares models)
(B5)Turns unit on / off, shortcuts to lighting control screen SCREEN INDICATOR ICONS

MENU SCREEN

GAUGE SCREEN 1

GAUGE SCREEN 2

QUICK VIEW SCREEN

FUEL FLOW MANAGER SCREEN

DEPTH, AIR TEMP, WATER TEMP SCREEN

TANK(S) LEVEL SCREEN

GPS SCREEN

Page 8 of the Faria Instruments IS0250a user manual — BUTTON FUNCTIONS
Page 8 · click to enlarge
Page 8

Part II: System Setup SYSTEM SETUP Your Faria Antares unit should already have been setup by either the boat manufacturer or by your dealer. Check with your dealer before beginning the System Setup process. In order to get the optimal performance out of your Faria Antares unit, the following steps are recommended. Some of the information needed to complete the setup process will be contained in your boat owner’s manual. Be sure to have your boat owner’s manual available before beginning the Antares setup process. To begin, use the left or right arrows on the navigation pad to highlight the

on the screen indicator bar located at the bottom of the screen. Then use the down arrow on the navigation pad to scroll down to SYSTEM SETUP and press

Faria Instruments IS0250a — BUTTON FUNCTIONS diagram (page 8)
Fig. 5

Use the navigation pad to highlight SYSTEM SETUP, then press

1. INPUT SETUP
Faria Instruments IS0250a — BUTTON FUNCTIONS diagram (page 8)
Fig. 6

Use the navigation pad to highlight INPUT SETUP, then press

Input Setup will allow you select which analog senders are connected to your Antares unit.

To activate or deactivate a sender, use the left or right navigation buttons to select either TANK 1, TANK 2, TRIM / TANK 3, AIR TEMP or SPEED SOURCE. Once the desired selection is highlighted, press

. Now use the up or down navigation buttons to highlight the desired setting, then press

icon on the Save Changes bar will automatically highlight. If your changes are correct, press

. The

to save.

will appear to confirm that changes have been saved. If the changes are not correct, use the navigation pad to highlight

will appear to confirm that the changes have not been saved. Refer to the list of available INPUTS on the next page for further instructions.

Antares Menu Screen · and press

Page 9 of the Faria Instruments IS0250a user manual — BUTTON FUNCTIONS
Page 9 · click to enlarge
Page 9

*For sender connection information, refer to wiring diagram HN0605 in Part VI (pg. 36) for further information.

Faria Instruments IS0250a — BUTTON FUNCTIONS diagram (page 9)
Fig. 7

TANK 1 – Select the type of level sender connected to Pin 5 on HN0605*. If nothing is connected, select “NONE”. TANK 2 – Select the type of level sender connected to Pin 6 on HN0605*. If nothing is connected, select “NONE”. TRIM / TANK 3 – Choose the type of analog trim sender or level sender connected to Pin 7 on HN0605*. If nothing is connected, select “NONE”. AIR TEMP – Select “INSTALLED” if an analog Air Temp sender is connected to Pin 9 on HN0605*. If an air temp sender is not connected, select “NOT INSTALLED”

Faria Instruments IS0250a — BUTTON FUNCTIONS diagram (page 9)
Fig. 8
Faria Instruments IS0250a — BUTTON FUNCTIONS diagram (page 9)
Fig. 9
Faria Instruments IS0250a — BUTTON FUNCTIONS diagram (page 9)
Fig. 10
Faria Instruments IS0250a — BUTTON FUNCTIONS diagram (page 9)
Fig. 11

SPEED SOURCE – Choose the type of speed signal to be used by the Antares. Refer to your boats owner’s manual to determine which type of speed options are installed on your boat and are connected to your Antares. DIGITAL PWS – A digital paddlewheel sender is connected via the J1939 backbone. GPS – A NMEA0183 GPS signal is connected. * ANALOG PWS – An analog paddlewheel sender is connected to pin 9 on HN0605. * NONE – No speed signal is connected. Once you have saved all the appropriate settings, press

to return to the SYSTEM SETUP menu.

Page 10 of the Faria Instruments IS0250a user manual — BUTTON FUNCTIONS
Page 10 · click to enlarge
Page 10
2. TANK SETUP
Faria Instruments IS0250a — BUTTON FUNCTIONS diagram (page 10)
Fig. 12

Use the navigation pad to highlight TANK SETUP, then press

Tank Setup will allow you to 1) Name each tank 2) Set each tank’s capacity and 3) Set a low level warning for each tank.

. Now scroll up or down to select the setting to change and use the left or right arrows to make the appropriate changes.

Faria Instruments IS0250a — BUTTON FUNCTIONS diagram (page 10)
Fig. 13

on the “Fuel Tank?” option, you are indicating that the tank connected to the associated sender is a fuel tank. Any tank that is indicated as a fuel tank will be used by the Fuel Flow Manager for calculation. If the associated tank is not a fuel tank, then select

. Improper tank indication will effect the performance of the Fuel Flow Manager.

Once you have adjusted all the options to the desired settings, press

. The

icon on the Save Changes bar will automatically highlight. If your changes are correct, press

will appear to confirm that the changes have been saved. If the changes are not correct, use the navigation pad to highlight

to save.

will appear to confirm that the changes have not been saved. Once you have saved all the appropriate settings, press

to return to the SYSTEM SETUP menu.

and press

Page 11 of the Faria Instruments IS0250a user manual — BUTTON FUNCTIONS
Page 11 · click to enlarge
Page 11
3. Depth Setup
Faria Instruments IS0250a — BUTTON FUNCTIONS diagram (page 11)
Fig. 14

Use the navigation pad to highlight DEPTH SETUP, then press

Depth Setup will allow you to set the shallow water alarm, set the deep water alarm, and set the keel offset.

Note: A digital depth transducer must be installed on your boat for the depth option to work. Refer to your owner’s manual to determine if there is a transducer installed. Your Antares will automatically recognize if a compatible digital depth sounder is installed. Use the up or down arrows on the navigation pad to highlight the desired option, then use the left or right arrows on the navigation pad to make the appropriate changes.

Faria Instruments IS0250a — BUTTON FUNCTIONS diagram (page 11)
Fig. 15

Once you have adjusted all the options to the desired settings, press

. The

icon on the Save Changes bar will automatically highlight. If your changes are correct, press

will appear to confirm that the changes have been saved. If the changes are not correct, use the navigation pad to highlight

to save.

will appear to confirm that the changes have not been saved. Once you have saved all the appropriate settings, press

to return to the SYSTEM SETUP menu. YOU ARE NOW FINISHED WITH THE SETUP PROCESS. PRESS

TO RETURN TO THE MAIN MENU SCREEN. SIMPLY USE THE NAVIGATION PAD TO MOVE YOUR WAY THROUGH THE ANTARES DISPLAY SCREENS. YOU ARE NOW READY TO HEAD OUT ON TO THE WATER.

and press

Page 12 of the Faria Instruments IS0250a user manual — MENU SCREEN
Page 12 · click to enlarge
Page 12
Part IIIOperating Instructions

Your Faria Antares unit has 8 main display screens and an optional Radio Control Screen. When a screen is selected, the Screen Indicator Icon on the Screen Indicator Bar located

at the bottom of the screen will be highlighted (

). Use the right or left arrows on the navigation pad to scroll through the available display screens. To activate the optional Radio Control Screen, press the button if available. SCREEN INDICATOR ICONS

MENU SCREEN

GAUGE SCREEN 1

GAUGE SCREEN 2

QUICK VIEW SCREEN

FUEL FLOW MANAGER SCREEN

DEPTH, AIR TEMP, WATER TEMP SCREEN

TANK(S) LEVEL SCREEN

GPS SCREEN

Page 13 of the Faria Instruments IS0250a user manual — GAUGE SCREEN 1
Page 13 · click to enlarge
Page 13

GAUGE SCREEN 1

/ GAUGE SCREEN 2

Faria Instruments IS0250a — GAUGE SCREEN 1 diagram (page 13)
Fig. 16
Faria Instruments IS0250a — GAUGE SCREEN 1 diagram (page 13)
Fig. 17

Gauge Screen 1 and Gauge Screen 2 provide a quick glance at up to 12 different gauge functions. Each quadrant can be customized to display any piece of information available. To customize a quadrant, press

. The upper left quadrant will be highlighted yellow as pictured below. Now use the navigation pad to select the quadrant you wish to change. When the desired

Faria Instruments IS0250a — GAUGE SCREEN 1 diagram (page 13)
Fig. 18

quadrant is highlighted, press

. A list of options will appear in the center of the screen. Use the up or down arrows on the navigation pad to highlight the desired information to be displayed, then press

. The highlighted quadrant will change to the selected display. Once you have set all of the quadrants to the desired information, press

Faria Instruments IS0250a — GAUGE SCREEN 1 diagram (page 13)
Fig. 19
Faria Instruments IS0250a — GAUGE SCREEN 1 diagram (page 13)
Fig. 20

the normal operating mode.

to return to

Page 14 of the Faria Instruments IS0250a user manual — QUICK VIEW SCREEN
Page 14 · click to enlarge
Page 14

QUICK VIEW SCREEN

Faria Instruments IS0250a — QUICK VIEW SCREEN diagram (page 14)
Fig. 21

The Quick View screen provides a large digital display for quick, easy reading. Use the up or down navigation buttons to scroll through the available information.

Faria Instruments IS0250a — QUICK VIEW SCREEN diagram (page 14)
Fig. 22
Faria Instruments IS0250a — QUICK VIEW SCREEN diagram (page 14)
Fig. 23
Faria Instruments IS0250a — QUICK VIEW SCREEN diagram (page 14)
Fig. 24
Faria Instruments IS0250a — QUICK VIEW SCREEN diagram (page 14)
Fig. 25
Page 15 of the Faria Instruments IS0250a user manual — FUEL FLOW MANAGER SCREEN
Page 15 · click to enlarge
Page 15

FUEL FLOW MANAGER SCREEN

Faria Instruments IS0250a — FUEL FLOW MANAGER SCREEN diagram (page 15)
Fig. 26

The Fuel Flow Manager screen provides all the necessary information to optimize the fuel consumption performance of your boat. The upper two quadrants can be customized to display various fuel flow information. To customize these quadrants, press

. The upper left quadrant will be highlighted yellow as pictured below.

Faria Instruments IS0250a — FUEL FLOW MANAGER SCREEN diagram (page 15)
Fig. 27

Use the left or right navigation buttons to highlight either of the upper quadrants. When the desired quadrant is highlighted, press

. A list of available fuel flow information will appear in the center of the screen. Use the up or down navigation buttons to highlight the desired information to be displayed, then press

. The highlighted quadrant will change to the display selected. Once you have set the quadrants to the desired information, press

to return to the normal operating mode.

Faria Instruments IS0250a — FUEL FLOW MANAGER SCREEN diagram (page 15)
Fig. 28
Faria Instruments IS0250a — FUEL FLOW MANAGER SCREEN diagram (page 15)
Fig. 29
Page 16 of the Faria Instruments IS0250a user manual — DEPTH / TEMP SCREEN
Page 16 · click to enlarge
Page 16

DEPTH / TEMP SCREEN

Faria Instruments IS0250a — DEPTH / TEMP SCREEN diagram (page 16)
Fig. 30

The Depth / Temp screen will display the current depth, air temperature, and water temperature. For Depth and Water Temperature, a digital Depth / Water Temp transducer must be installed. If no transducer is installed then the Depth quadrant will display “Transducer Not Installed” and the Water quadrant will display “N/A”. For Air Temperature, an analog Air Temperature sender must be installed. If no sender is installed then the Air quadrant will display “N/A”. Refer to your boat owner’s manual to determine which transducers are installed on your boat.

Page 17 of the Faria Instruments IS0250a user manual — TANK LEVEL SCREEN
Page 17 · click to enlarge
Page 17

TANK LEVEL SCREEN

The tank level screen will display tank level information as reported by the tank’s level sender. Your Antares unit can display level information for up to three tanks. Tanks must be activated during the setup process to be displayed on this screen. See Part II: System Setup for more information on tank setup. Dual Tank Display Three Tank Display

Faria Instruments IS0250a — TANK LEVEL SCREEN diagram (page 17)
Fig. 31
Faria Instruments IS0250a — TANK LEVEL SCREEN diagram (page 17)
Fig. 32
Faria Instruments IS0250a — TANK LEVEL SCREEN diagram (page 17)
Fig. 33
Page 18 of the Faria Instruments IS0250a user manual — GPS SCREEN
Page 18 · click to enlarge
Page 18

GPS SCREEN

Faria Instruments IS0250a — GPS SCREEN diagram (page 18)
Fig. 34
Faria Instruments IS0250a — GPS SCREEN diagram (page 18)
Fig. 35

Magnetic North Signal Available No Magnetic North Signal Available The GPS Screen will display COG, Latitude, and Longitude when a NMEA0183 GPS Antenna is installed. You do not need to change any settings when installing a GPS antenna. Your Antares unit will automatically recognize if a compatible GPS antenna is connected. When the GPS signal is acquiring the Antares will display “ACQUIRING GPS” If no GPS antenna is installed, then “NO GPS” will appear.

Faria Instruments IS0250a — GPS SCREEN diagram (page 18)
Fig. 36
Faria Instruments IS0250a — GPS SCREEN diagram (page 18)
Fig. 37

Acquiring GPS Signal GPS not connected Refer to your boat owner’s manual to determine if a NMEA0183 GPS antenna has been installed with the Faria Antares system.

For full details regarding Magnetic and True North GPS readings visit NOAA’s National Geophysical Data Center website. http://www.ngdc.noaa.gov/seg/geomag/declination.shtml

Page 19 of the Faria Instruments IS0250a user manual — RADIO CONTROL SCREEN
Page 19 · click to enlarge
Page 19

RADIO CONTROL SCREEN

To enter the Radio Control Screen, press the button The Radio Control Screen allows you to control certain functions of your boat’s Jensen radio. This option is not available on all Antares models and requires a compatible Jensen radio. For a list of compatible radios, visit www.faria- instruments.com/antares.html Press up or down on the navigation button to scroll through the various radio control functions. Then press left, right, or

Faria Instruments IS0250a — RADIO CONTROL SCREEN diagram (page 19)
Fig. 38

to adjust the highlighted control function Press

to turn radio on / off Press right or left on the navigation button to increase / decrease volume. Press

again to deactivate. Press right on the navigation button to change radio mode Ex:

to activate Mute. Press

Press right on the navigation button to change band Ex: FM1, FM2, SAT

Press right or left on the navigation pad once to Tune, press and hold to Seek

Press right or left on the navigation pad for Shift, press and hold to Scan. Press

at any time to exit the Radio Control Screen

Page 20 of the Faria Instruments IS0250a user manual — MAIN MENU SCREEN
Page 20 · click to enlarge
Page 20

MAIN MENU SCREEN

Faria Instruments IS0250a — MAIN MENU SCREEN diagram (page 20)
Fig. 39

The Main Menu screen provides access to the various setup screens available on your Faria Antares unit. Use the up or down navigation buttons to highlight the desired menu option, then press

. A detailed description of each sub-menu is contained in Part IV: Menu Options / User Settings.

Page 21 of the Faria Instruments IS0250a user manual — LIGHTING
Page 21 · click to enlarge
Page 21
Part IVMenu Options / User Settings

LIGHTING

Faria Instruments IS0250a — LIGHTING diagram (page 21)
Fig. 40

This screen can also be accessed by tapping the button at any time. Use the up or down navigation buttons to highlight the desired setting to adjust, then use the left or right navigation buttons to adjust the highlighted section. Press

to save your changes and exit to the previous screen or

to exit to the previous screen without saving.

Page 22 of the Faria Instruments IS0250a user manual — FUEL MANAGER
Page 22 · click to enlarge
Page 22

FUEL MANAGER

Faria Instruments IS0250a — FUEL MANAGER diagram (page 22)
Fig. 41
Faria Instruments IS0250a — FUEL MANAGER diagram (page 22)
Fig. 42

STOP: Your fuel tanks must be activated and set to the proper capacity before the fuel manager will become functional. Refer to Part II: SYSTEM SETUP for further information. It is CRITICAL that you correctly set the TOTAL AMOUNT OF FUEL each time you refuel.

Total Amount of Fuel = Fuel Added + Fuel Remaining Use the up or down navigation buttons to highlight the desired setting, then use the left or right navigation buttons to change the value of the highlighted area. You can make changes to all of the Fuel Manager options before saving. Once all the changes have been properly set, press

icon on the Save Changes bar will automatically highlight. If your changes are correct, press

. The

to save.

will appear to confirm that changes have been saved. If the changes are not correct, use the navigation pad to highlight

will appear to confirm that the changes have not been saved. Note: The TOTAL AMOUNT OF FUEL must be set to the proper value to insure accurate performance from the Fuel Manager.

and press

Page 23 of the Faria Instruments IS0250a user manual — SYSTEM SETUP
Page 23 · click to enlarge
Page 23

SYSTEM SETUP

Refer to Part II: System Setup, pages 6-9 for detailed information.

Page 24 of the Faria Instruments IS0250a user manual — UNITS
Page 24 · click to enlarge
Page 24

UNITS

Faria Instruments IS0250a — UNITS diagram (page 24)
Fig. 43
Faria Instruments IS0250a — UNITS diagram (page 24)
Fig. 44

The Units screen will allow you to change the display values for Fluids, Pressure, Depth, Temperature, Speed, and Distance. Use the left or right navigation buttons to highlight the desired option to change, then use the up or down navigation buttons to change the value located directly below the highlighted option. You can make changes to all of the listed options before saving. Once all the changes have been properly set, press

icon on the Save Changes bar will automatically highlight. If your changes are correct, press

. The

to save.

will appear to confirm that the changes have been saved. If the changes are not correct, use the navigation pad to highlight

will appear to confirm that the changes have not been saved.

and press

Page 25 of the Faria Instruments IS0250a user manual — CALIBRATE
Page 25 · click to enlarge
Page 25

CALIBRATE

Your Faria Antares unit is factory calibrated to give you optimal performance with the senders installed on your boat. In order to further insure that you are getting the most accurate readings possible, we have made the following calibrations available to you. To adjust your speedometer calibration or trim calibration, use the up or down navigation buttons to highlight the desired option, then press

Faria Instruments IS0250a — CALIBRATE diagram (page 25)
Fig. 45
Faria Instruments IS0250a — CALIBRATE diagram (page 25)
Fig. 46
Page 26 of the Faria Instruments IS0250a user manual — SPEEDOMETER CALIBRATION
Page 26 · click to enlarge
Page 26

SPEEDOMETER CALIBRATION

to begin speedometer calibration, then follow the on-screen instructions. Your actual speed as reported by the active speed source will be displayed in the lower left quadrant. If you have a GPS antenna connected to the Antares unit and a signal is present, then your speed as reported by the GPS antenna will be displayed in the lower right quadrant. If no GPS antenna is attached to the Antares unit, then use a secondary GPS speed source for calibration.

Faria Instruments IS0250a — SPEEDOMETER CALIBRATION diagram (page 26)
Fig. 47
1. Press
Faria Instruments IS0250a — SPEEDOMETER CALIBRATION diagram (page 26)
Fig. 48
2. Press the left or right arrows on the navigation button to increase or decrease the speed value in the highlighted quadrant. Step 3: When the speed value in the highlighted quadrant matches or is close the GPS speed value displayed in the lower right quadrant or the GPS speed value displayed on your secondary GPS speed source, press

. When calibration is complete, “CALIBRATION SUCCESFUL” will be displayed and the Antares will automatically return to the previous screen.

Faria Instruments IS0250a — SPEEDOMETER CALIBRATION diagram (page 26)
Fig. 49
Page 27 of the Faria Instruments IS0250a user manual — TRIM CALIBRATION
Page 27 · click to enlarge
Page 27

TRIM CALIBRATION

Faria Instruments IS0250a — TRIM CALIBRATION diagram (page 27)
Fig. 50

to begin Trim Calibration, then follow the on-screen instructions.

1. Set your engine to its full down position, then press
Faria Instruments IS0250a — TRIM CALIBRATION diagram (page 27)
Fig. 51
2. Set your engine to the top of its trim range (prop still in water), then press
Faria Instruments IS0250a — TRIM CALIBRATION diagram (page 27)
Fig. 52
. Step 3Set your engine to the top of its trailer / full-up position, then press
Faria Instruments IS0250a — TRIM CALIBRATION diagram (page 27)
Fig. 53

Once step 3 is completed, the screen will display “TRIM CALIBRATION COMPLETE” and the

Faria Instruments IS0250a — TRIM CALIBRATION diagram (page 27)
Fig. 54

icon on the Save Changes bar will automatically highlight. If ALL steps were followed correctly, press

will appear to confirm that the changes have been saved. If ALL steps were not followed correctly, use the navigation pad to highlight

to save.

will appear to confirm that the changes have not been saved. The Antares will automatically return to the previous screen.

Press · and press

Page 28 of the Faria Instruments IS0250a user manual — SELF TEST
Page 28 · click to enlarge
Page 28

SELF TEST

Your Faria Antares will automatically run a self-diagnostics test when this menu option is selected. The test may take up to 3 minutes. If no problems are found, the screen will display “TEST SUCCESSFUL”. If a problem is found, the screen will display “Error(s) Found”. If this occurs, contact Faria Customer Service. Refer to Part VIII: Warranty for further information. After running the self-diagnostics test, the Antares will automatically return to the Main Menu screen.

Faria Instruments IS0250a — SELF TEST diagram (page 28)
Fig. 55
Faria Instruments IS0250a — SELF TEST diagram (page 28)
Fig. 56
Page 29 of the Faria Instruments IS0250a user manual — MASTER RESET
Page 29 · click to enlarge
Page 29

MASTER RESET

This screen will appear when Master Reset is selected from the Main Menu screen.

Faria Instruments IS0250a — MASTER RESET diagram (page 29)
Fig. 57
Faria Instruments IS0250a — MASTER RESET diagram (page 29)
Fig. 58

will automatically be highlighted. If you do not wish to perform a Master Reset, be sure that

to return to the previous screen without performing a Master Reset. WARNING: Performing a Master Reset will return all user defined and manufacturer set values to the default values.

is highlighted and press

. You can also press

Page 30 of the Faria Instruments IS0250a user manual — DIAGNOSTICS
Page 30 · click to enlarge
Page 30

DIAGNOSTICS

Faria Instruments IS0250a — DIAGNOSTICS diagram (page 30)
Fig. 59
Faria Instruments IS0250a — DIAGNOSTICS diagram (page 30)
Fig. 60

The Diagnostics page displays the most recent engine error codes as reported by the engine’s ECU. “Hours” indicates at what engine hour an engine error has occurred. “Error” indicates which engine error occurred. To exit, press

Page 31 of the Faria Instruments IS0250a user manual — DIAGNOSTICS
Page 31 · click to enlarge
Page 31
Part VAlarms

Your Faria Antares unit will display 3 types of alarms; 1) Engine Alarms 2) Fuel/Tank Level Alarms and 3) Depth Alarms. When an alarm condition is present, an “Alarm” pop-up window will appear (see image below) and alarm icons will flash in the lower corners of the display screen.

To close the alarm pop-up window and silence the alarm, press

Faria Instruments IS0250a — DIAGNOSTICS diagram (page 31)
Fig. 61

. The alarm icons will continue to flash in the lower corners of the display screen until the alarm condition is corrected. Alarm Icons

Faria Instruments IS0250a — DIAGNOSTICS diagram (page 31)
Fig. 62

Engine Alarm Active Depth Alarm Active

Faria Instruments IS0250a — DIAGNOSTICS diagram (page 31)
Fig. 63

Fuel / Tank Level Alarm Active When an alarm condition is corrected, an “Alarms Cleared” pop-up window will appear.

Faria Instruments IS0250a — DIAGNOSTICS diagram (page 31)
Fig. 64
Faria Instruments IS0250a — DIAGNOSTICS diagram (page 31)
Fig. 65

to close the Alarms Cleared window

You MUST press

Page 32 of the Faria Instruments IS0250a user manual — DIAGNOSTICS
Page 32 · click to enlarge
Page 32
Page 32 of the Faria Instruments IS0250a user manual — DIAGNOSTICS
Page 33 of the Faria Instruments IS0250a user manual — TABLE 5.1
Page 33 · click to enlarge
Page 33

ENGINE ALARMS LIST Your Antares unit will display the engine alarms listed in table 5.1. The Antares will display engine alarms as they are reported by the engine’s ECU. The Antares may not be able to display all available engine alarms. When available, the Antares will give a detailed description of the active alarm condition(s). If a description is not provided by the engine’s ECU, the Antares unit will most likely display “Miscellaneous Engine Fault” in the alarm pop-up window. NOTE: Many engines are equipped with an internal protection system. In the event that this protection system is activated by the engine’s ECU, your Antares unit may display “Engine Emergency Stop” in the alarm pop-up window. If this occurs, your engine’s ECU may limit power and it is recommended that you contact your dealer or marina immediately. The Faria Antares unit has no control over your engine’s internal protection system.

Faria Instruments IS0250a — TABLE 5.1 diagram (page 33)
Fig. 66

TABLE 5.1

Page 34 of the Faria Instruments IS0250a user manual — TABLE 5.1
Page 34 · click to enlarge
Page 34

Part VI: Installation / Wiring Diagrams INSTALLATION Your Faria Antares unit can be mounted to your instrument panel in 4 ways; Panel Mount, Flush Mount, Gauge Mount, and Gimble Mount Panel Mount Step 1: Cut a square hole with rounded corners to match the dimensions as indicated in the figure below. Step 2: Insert the Antares unit from front of panel, placing the Panel Mount Gasket (GK0206) between the Antares and the panel. Step 3: From back of panel, install back clamp. The four interior studs should line up with the four interior holes of the back clamp. Tighten the supplied nuts, washers, and lock washers to 7-10 inch pounds (slightly more than finger tight) Step 4: Connect 9-pin (HN0604) and 20-pin (HN0605) wire harnesses to back of Antares unit. Proper connection requires the locking ring on each harness to be rotated about ¼ turn. Step 5: Connect available inputs to corresponding wire harnesses. See pages 34-37 for detailed wiring information

Faria Instruments IS0250a — TABLE 5.1 diagram (page 34)
Fig. 67
Page 35 of the Faria Instruments IS0250a user manual — TABLE 5.1
Page 35 · click to enlarge
Page 35

Flush Mount Step 1: Cut a square hole with rounded corners to match the dimensions as indicated in the figure below. Step 2: Install mounting studs at the dimensions indicated in the figure. Step 3: Insert the Antares unit from back of panel, placing the Flush Mount Gasket (GK0207) between the Antares and the panel. Step 4: From back of panel, install back clamp. The four interior studs should line up with the four interior holes of the back clamp. Tighten the supplied nuts, washers, and lock washers to 7-10 inch pounds (slightly more than finger tight) Step 5: Connect 9-pin (HN0604) and 20-pin (HN0605) wire harnesses to back of Antares unit. Proper connection requires the locking ring on each harness to be rotated about ¼ turn. Step 6: Connect available inputs to corresponding wire harnesses. See pages 34-37 for detailed wiring information

Faria Instruments IS0250a — TABLE 5.1 diagram (page 35)
Fig. 68
Page 36 of the Faria Instruments IS0250a user manual — TABLE 5.1
Page 36 · click to enlarge
Page 36

Gauge Mount Step 1: Cut a 3 3/8” round hole in your boat’s console Step 2: Insert the Antares through the hole, placing the Gauge mount gasket (GK1234) between the Antares unit and the panel. Step 3: From back of panel, install back clamp. The two interior studs should line up with the two holes of the back clamp. Tighten the supplied nuts, washers, and lock washers to 7-10 inch pounds (slightly more than finger tight) Step 4: Connect 9-pin (HN0604) and 20-pin (HN0605) wire harnesses to back of Antares unit. Proper connection requires the locking ring on each harness to be rotated about ¼ turn. Step 5: Connect available inputs to corresponding wire harnesses. See pages 34-37 for detailed wiring information

Faria Instruments IS0250a — TABLE 5.1 diagram (page 36)
Fig. 69
Faria Instruments IS0250a — TABLE 5.1 diagram (page 36)
Fig. 70
Faria Instruments IS0250a — TABLE 5.1 diagram (page 36)
Fig. 71
Page 37 of the Faria Instruments IS0250a user manual — TABLE 5.1
Page 37 · click to enlarge
Page 37

Gimble Mount Step 1: Locate a flat surface on your boat’s console to install the Antares Gimble Mount Bracket. Step 2: Using a 3/16” drill bit, drill two holes 2.7” inches apart as indicated in the figure below. Step 3: Using the supplied mounting hardware, mount the Gimble bracket through the holes you just drilled Step 4: Using the supplied fasteners, mount the Antares unit into the Gimble bracket. Step 5: Connect 9-pin (HN0604) and 20-pin (HN0605) wire harnesses to back of Antares unit. Proper connection requires the locking ring on each harness to be rotated about ¼ turn. Step 6: Connect available inputs to corresponding wire harnesses. See pages 34-37 for detailed wiring information

Faria Instruments IS0250a — TABLE 5.1 diagram (page 37)
Fig. 72
Faria Instruments IS0250a — TABLE 5.1 diagram (page 37)
Fig. 73
Faria Instruments IS0250a — TABLE 5.1 diagram (page 37)
Fig. 74
Page 38 of the Faria Instruments IS0250a user manual — NMEA0183 GPS ANTENNA
Page 38 · click to enlarge
Page 38
Faria Instruments IS0250a — GPS FARIA BUS ENGINE ECU RS232 diagram (page 38)
Fig. 75
Faria Instruments IS0250a — GPS FARIA BUS ENGINE ECU RS232 diagram (page 38)
Fig. 76

HN0604 ECU / GPS Harness

Faria Instruments IS0250a — GPS FARIA BUS ENGINE ECU RS232 diagram (page 38)
Fig. 77

GPS FARIA BUS ENGINE ECU RS232

Faria Instruments IS0250a — GPS FARIA BUS ENGINE ECU RS232 diagram (page 38)
Fig. 78
Faria Instruments IS0250a — GPS FARIA BUS ENGINE ECU RS232 diagram (page 38)
Fig. 79
Faria Instruments IS0250a — GPS FARIA BUS ENGINE ECU RS232 diagram (page 38)
Fig. 80
Faria Instruments IS0250a — GPS FARIA BUS ENGINE ECU RS232 diagram (page 38)
Fig. 81

NMEA0183 GPS ANTENNA

HN0604

Page 39 of the Faria Instruments IS0250a user manual — HN0605
Page 39 · click to enlarge
Page 39
Faria Instruments IS0250a — HN0605 diagram (page 39)
Fig. 82

HN0605 – Power / Analog Harness

Faria Instruments IS0250a — HN0605 diagram (page 39)
Fig. 83
Faria Instruments IS0250a — HN0605 diagram (page 39)
Fig. 84

FARIA BUS Power / Gnd Tank 1 / Tank 2 Tank 3 or Trim Air Temp or Analog PWS Radio

Faria Instruments IS0250a — HN0605 diagram (page 39)
Fig. 85
Faria Instruments IS0250a — HN0605 diagram (page 39)
Fig. 86
Faria Instruments IS0250a — HN0605 diagram (page 39)
Fig. 87
Faria Instruments IS0250a — HN0605 diagram (page 39)
Fig. 88
Faria Instruments IS0250a — HN0605 diagram (page 39)
Fig. 89
Faria Instruments IS0250a — HN0605 diagram (page 39)
Fig. 90

HN0605

Page 40 of the Faria Instruments IS0250a user manual — HN0605
Page 40 · click to enlarge
Page 40

HN0604

Faria Instruments IS0250a — HN0604 diagram (page 40)
Fig. 91

HN0605

Faria Instruments IS0250a — HN0605 diagram (page 40)
Fig. 92
Page 41 of the Faria Instruments IS0250a user manual — HN0605
Page 41 · click to enlarge
Page 41
Part VIIFAQ / Troubleshooting

The following items are common questions regarding the installation and use of the Antares unit. If you are experiencing a problem not described in the FAQ section, please visit www.faria-instruments.com/antares.html for more detailed troubleshooting.

Problem Possible Cause Solution

Faria Instruments IS0250a — HN0605 diagram (page 41)
Fig. 93

Install a compatible digital depth / water temp transducer

Install a NMEA0183 GPS antenna Improper connection Check connection

Only some Antares are available with Radio control. If your Antares does not have a Blue Radio Button, then it does not have the radio control option

Check connection of Jensen Remote Harness to Radio Plug on HN0605 (pg. 36) Fuel Flow Manager not Working Tanks not properly set up

Set Amount of Fuel to actual amount of fuel in tank(s). Refer to FUEL MANAGER, page 21 for instructions.

Page 42 of the Faria Instruments IS0250a user manual — HN0605
Page 42 · click to enlarge
Page 42
Page 42 of the Faria Instruments IS0250a user manual — HN0605
Page 43 of the Faria Instruments IS0250a user manual — WARRANTY SERVICE,
Page 43 · click to enlarge
Page 43
Faria Instruments IS0250a — Faria® Marine Instruments diagram (page 43)
Fig. 94 · Faria® Marine Instruments
Faria Instruments IS0250a — Faria® Marine Instruments diagram (page 43)
Fig. 95 · Faria® Marine Instruments
Faria Instruments IS0250a — Faria® Marine Instruments diagram (page 43)
Fig. 96 · Faria® Marine Instruments
Faria Instruments IS0250a — Faria® Marine Instruments diagram (page 43)
Fig. 97 · Faria® Marine Instruments
Faria Instruments IS0250a — Faria® Marine Instruments diagram (page 43)
Fig. 98 · Faria® Marine Instruments
Faria Instruments IS0250a — Faria® Marine Instruments diagram (page 43)
Fig. 99 · Faria® Marine Instruments

Fog Resistant Lens Only $10.00

2 inch instruments $15.00

2 inch Clock or Hourmeter $30.00

2 inch Warning System Indicator $35.00

During the first 36 months from date of original retail purchase (12 months on PWC, fog resistant gauges, Fuel Managers, Depth Sounders, Commander-Speedo, Commander-Tach, Pilot I, Pilot II and MG2000), any instruments that fail due to defects in materials or workmanship will be repaired or replaced at Faria® Marine Instruments’ option at no charge. Te Warranty is further extended indefinitely beyond the initial warranty period by enclosing the nominal fee as listed when submitting a warranty claim.

2 inch Honda Trim $35.00

Digital Depth Sounder $55.00

Fuel Flow Manager $90.00

Flux Gate Compass $75.00

Flux Gate Compass with Sensor $140.00

Speedometer or Water Pressure gauge $15.00

Electronic Speedometer with sensor $50.00

To submit a Warranty Claim, call Faria® Customer Service at 1-800-473-2742 weekdays 8:30 a.m. until 5:00 p.m. Eastern Time. One of our Marine Applications Specialists will review the problem with you in detail. If no solution is found, you will be given an authorization number to return the instrument, postage prepaid and packaged to prevent damage while in transit, along with your name, address, daytime telephone number, sales receipt, and a brief description of the problem, to:

Tachometer, Synchronizer or Electronic Speedometer $30.00

Tachometer with Hourmeter or System Indicator $50.00

Pilot Speedometer or Tachometer $125.00

Commander Tachometer or Speedometer $125.00

Multifunction Instrument $40.00

Faria® Marine Instruments

MG2000 Speedometer or Tachometer $175.00

WARRANTY SERVICE,

Serial Bus Gateway Box $400.00

P.O. Box 983, 385 Norwich-New London Turnpike Uncasville, CT 06382-0983.

It will be promptly returned to you postage prepaid once analyzed, repaired or replaced. Instrument styles which are no longer manufactured, may be replaced with a similar instrument of equal or greater value. Flux-Gate Compass Systems should be returned with sensor. For warranty service beyond the initial warranty period, be certain to include your check or money order as stated on the Warranty fees table.

Removal / reinstallation expenses, any damage to an instrument resulting from natural disasters, misuse, neglect, accident, misapplication, improper installation, unauthorized repair or alteration, and instruments purchased prior to March 1, 1985 are not covered by this warranty. Instruments returned to Faria® Marine Instruments that are not covered under this warranty will be repaired or replaced at our nominal service rates or returned to you as is, at your option. Faria® Marine Instruments expressly disclaims any liability for incidental of consequential damage caused by product defects. Some states do not allow the exclusion or limitation of consequential damages, so the above may not apply to you. Te Warranty herein is in lieu of any other expressed warranty of merchantability or fitness or any other obligation on the part of Faria® Marine Instruments, the Tomas G. Faria Corporation, or the seller. All implied warranties are limited to the initial 36 month period. Some states do not allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you. Tis warranty gives you specific legal rights, and you also have other rights which vary from state to state.

*Tese fees are in effect as of 08/17/2007 and are subject to change without notice.

IS0090F 8/2007 ecr7049

Page 44 of the Faria Instruments IS0250a user manual — Faria® Marine Instruments
Page 44 · click to enlarge
Page 44
Page 44 of the Faria Instruments IS0250a user manual — Faria® Marine Instruments

Ask about the Faria Instruments IS0250a

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Faria Instruments IS0250a

Be the first to ask — other owners or our team will answer.

Original document

Faria Instruments IS0250a manual PDF

44 pages·7.7 MB·Fish Finder·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…