WARNING
CAUTION
ELECTRICAL SHOCK HAZARD Do not open the equipment unless totally familiar with electrical circuits and service manual.
Observe the following compass safe distances to prevent deviation of a magnetic compass:
Only qualified personnel should work inside the equipment.
Turn off the power at the switchboard before beginning the installation.
Fire or electrical shock can result if the power is left on.
Do not install the equipment where it may get wet from rain or water splash.
Water in the equipment can result in fire, electrical shock or equipment damage.
Be sure no water leaks in at the trans- ducer mounting location.
Water leakage can sink the vessel. Also confirm that the transducer will not loosen by ship’s vibration. The installer of the equipment is solely responsible for the proper installation of the equipment. FURUNO will assume no responsibility for any damage associated with improper installation.
When handling the transducer cable, keep in mind following points. Keep the cable away from oil and fuel. Keep the cable away from the place where it may be damaged during the installation. Do not paint the cable.
Be sure that the power supply is compatible with the voltage rating of the equipment.
The sheath of the transducer cable is made of chlorophrene rubber (or vinyl chloride). Therefore, do not paint the sheath with organic liquid (such as toluene) since it may harm the sheath.
Connection of an incorrect power supply can cause fire or equipment damage. The voltage rating of the equipment appears on the label above the power connector.

Standard Supply




IEC 61162-1
DIGITAL DEPTH INDICATOR
FE-720
IEC 61162-1
DISTRIBUTION BOX FE-702
IEC 61162-1
EIA-232C
100/110-115/ 200/220-230 VAC and DC24 V
BOX MB-1200
SWITCH BOX
EX-8
JB JB JB
JUNCTION BOX JISF8821-1M0 0-20A3P JB
JB
Matching Box MB-502 (For 50B-6B) MB-504 (For 200B-8B)
: Standard Supply
: Optional Supply
: Local Supply

NOTICE
Do not apply paint, anti-corrosive sealant or contact spray to coating or plastic parts of the equipment.
Those items contain organic solvents that can damage coating and plastic parts, especially plastic connectors.
1.2.1 Mounting consideration
The display unit can be installed on a tabletop, on the overhead, on the bulkhead or flush
mounted in a console or panel.
When selecting a mounting location for the display unit keep the following in mind.

generators.
unit and leave slack in cables.
following compass safe distances to prevent disturbance to the magnetic compass.
Steering compass: 0.40 meters

Desktop Overhead
1.2.2 Removing the cover
While pressing the center of the cover with your thumbs as illustrated, pull the cover towards
you to remove it.



There are two types of flush mount kits, F type and S type. For details, see the outline diagrams
at the back of this manual.
Dummy cover

Flush Mount Kit (F): OP02-79-1 (001-229-290)

and four spring washers (M6).
Flush Mount Kit (S): OP02-80 (001-229-320)

hex bolts (M6x12) and spring four washers (M6).
The installation of the transducer and the tank should be accomplished by a dockyard referring to the installation drawings at the back of this manual. An example of transducer installation method is also shown in paragraph 1.3.2.

To decide the location of the transducer, the following points should be taken into account.
from aeration possibly occurring beneath the hull and also not affected by engine and
propeller noise.
and spreads over the hull bottom approximately to three quarters. Air bubble streams vary in
form and intensity according to ship's speed, draught, trim, shape of bow and hull, as well as
sea state.
gives satisfactory results. As for vessels such as oil tankers whose fore draught is especially
shallow, an after position about three quarters of ship's length from the stern is often
suitable.
from the keel to minimize the effect of aerated water.
speed log sensor should be avoided.
tank to the hull.
bottom. Feed the transducer cable through the cable gland.

and electrical shielding as well as for protecting the cable from mechanical damage.
The conduit pipe should be fixed to the flange on the transducer tank. The pipe should
be of such a length to clear the water level when the ship is fully loaded. The pipe end
should be finished with filling compound. It is recommended to fill the pipe with sand
between the transducer and the junction box (or matching box). This will protect the
transducer from vibration and damage.

415 FIXING HOLE
*Sea water comes into the area marked with "*" inside the tank.
190.7+3
HULL PLATE
Transducer Tank for 50B-6B Transducer
1.4 Distribution Box
A magnetic compass will be affected if placed too close to the distribution box. Observe the
following compass safe distance to prevent disturbance to the magnetic compass.
Steering compass: 1.15 meters
Fasten the distribution box with four tapping screws (6x30) referring to the outline drawing at the
end of this manual.
* *

Fasten the matching box with four Trapping screws (6x20: local supply). Compass safe
distances are as follows; standard compass: 0.50 m, Steering compass: 0.40 m.
The indicator can be installed on a tabletop, on the overhead. Refer to outline drawings at the
end of this manual for installation instructions. When selecting a mounting location, keep in mind
motor or generator.
in cables, to facilitate maintenance and servicing.
Standard compass: 0.50 m, Steering compass: 0.40 m.
There are two types of flush mount kits, F type and S type. For details, see the outline diagrams
at the back of this manual.

Use the accessories FP65-00401 (See page A-7).
two spring washers (M6).
Use the accessories FP65-00402 (See page A-8).
spring washers (M6).


If two transducers are installed, the transducers switch box is required. Locate the transducer
switch box near the display unit considering length of the interconnection cable. Select the
bright place where the panel of equipment can be watched. Use only the screws supplied on the
terminal inside to make connections. Use of other screws may cause a short circuit. Compass
safe distances are as follows; standard compass: 1.00 m, Steering compass: 0.60 m.
Assemble the Gate Valve as shown below. Refer to the drawing at the end of this manual.
O-ring (P170), seachest cap and shaft assembly.
When assembling the gate valve, use original washers, bolts and nuts. Keep the bottom of the
seachest cap and the shaft free of dust and be careful not to damage them.

The hull side of the spacer should be flush with the hull bottom. Be careful not to damage the
side fixed to the gate valve.

gasket 1 onto the spacer.
gate valve should be up.
the bottom of seachest cap.
O-ring (P170) and gasket 2 are attached by adhesion of grease.
hand.
You will feel some resistance because of the O-ring (P135). (See the illustration on the previous

Washer
and the shaft assembly.

Wiring
Connect three cable assemblies (supplied) between the display unit and distribution box. See
the interconnection diagram for details.
Display unit FE-701 (rear panel)
FM-C6FPS002-100

When silencing the alarm beep, connect to *2 connector.
Power Sours for FE-701

When the Transducer Switch Box EX-8 or Distribution Box MB-1200 is used, the
interconnections are as follows.
MJ-A3SPF0015-100C
FM-C6FPS003-020

When silencing the alarm beep, connect to *2 connector.

Fabricate the power and other cables as illustrated below to connect them to the Distribution
box.


Clamp here.
*: Depending on cables, fabrications are as follows.
Crimp-on lug FV2-S3.3 Blue
Crimp-on lug FV1.25-3 Red

Several cables are required to supply at local. In this manual, JIS (Japan Industrial Standard ) cables are specified. Use equipment cables refering to the figures below.
Sheath
Shield
Sheath
Armor
Armor
Core S=1.5 mm
Core S=2.5 mm
=1.56mm
Vinyl sheath
=2.01mm
Vinyl sheath
DPYCYS-2.5 sectional view
Shield Sheath
Armor
Core S=1.5 mm
=1.56mm
Vinyl sheath
TPYCYS-1.5 sectional view
JIS Cables (Cross section)

TTYCYS is a Japan Industrial Standard (JIS) cable. Use the equipment one.
Vinyl Sheath Shield Cores

Vinyl Tape Vinyl Sheath

Clamp here.

Special tool for connecting wires, fitted inside the Distribution Box
Armor
Vinyl sheath Conductor
S =0.75 mm =1.11 mm
Anticorrosive sheath
Insert
(Sectional view)
Terminal Board TB1, TB3 Cross section
Power Supply Cable from Ship's Mains
If the ship's mains is AC, the power supply cable must be connected to TB5 in the Distribution
Box. In case of DC ship's mains, cable must be connected to TB6 in the Distribution Box. For
further information, refer to page 16.
Attach EMI core (supplied) to the power cable to prevent noise.

EMI core
To distribution box
2 Rotate

Connect the transducer cable to the distribution box. If necessary, attach the junction box
between the distribution box and matching box.
Connect the ground wire (2.0 sq.) from both the display unit and distribution box to ship’s
ground to prevent interference to the picture. Shorten the ground wire as much as possible.
The optional digital depth indicator FE-720 should be grounded by 1.25 sq. wire.
distribution box. Do not use an “open-type” lugs.

The power error and shallow water alarms, which produce audio and visual alarms in the event
of power failure and shallow water, can be output by connecting the distribution box to the ship’s
alarm system.
Connect the DPYCYS-1.5 cable between TB1 in the Distribution Box and the alarm system of
the ship referring to the schematic diagram at the end of this manual.
Select either one. Alarm System
NORMAL CLOSE NORMAL OPEN RELAY COMMON
DPYCYS-1.5
Digital Depth Indicator FE-720
There are two methods to connect the digital depth Indicator FE-720.
The interconnection is as follows.
DIGITAL DEPTH INDICATOR FE-720
IN/OUT
TB3
TTYCYS-4
1 2 3 4 5 6 7 8
< 1 < TD-A < 2 < TD-B < 3 < RD-A < 4 < RD-B < 5 < 24V < 6 < 0V
TD1-A TD1-B 24V 0V GND TD1-A TD1-B 24V 0V GND
1 2 3 4 5 6 7 8 9
GREEN RED BLACK
P
< 7 < GND
TERMINAL BOX DS-802(option)

When the main display unit FE-701 activates an alarm, it can be deactivated at the FE-701 itself
and also, it can be deactivated from the digital depth indicator FE-720. To do this, connect as
follows.
DIGITAL DEPTH INDICATOR FE-720
DISTRIBUTION BOX FE-702
MJ-A7SPF0009-020C
IN/OUT
TTYCYS-4
< 1 < TD-A < 2 < TD-B < 3 < RD-A < 4 < RD-B < 5 < 24V < 6 < 0V
1 2 3 4 5 6 7 8
YELLOW BLUE
GREEN RED BLACK
< 7 < GND
24 VDC +
p :Twisted pairs
In the menu of the FE-720, ALARM should be set to ON. If an alarm activates, press any key on
the FE-720, then the alarm will be deactivated at the FE-701 and FE-720.
MENU DIM CONTROL PANEL ONLY /LANG. ENGLISH UNITS ALARM SET ON TEST

This unit is set at factory to operate from 220-230 VAC ship's mains. For connection to a 100
VAC, 110-115 VAC, 200 VAC or 24 VDC ship's mains, modify the connections in the distribution
box as shown below.
power use.
Label inside the distribution box FE-702
100 VAC, 110-115 VAC, 200 VAC Ship's Mains
220-230 VAC (Default) Orange Red Black Brown White
200 VAC Red Orange Black Brown White
110-115 VAC Black Red Orange Brown White
100VAC Brown Red Black Orange White


For DC ship's mains For AC ship's mains
Distribution box, inside view

This section provides the procedures for initial set up of the equipment. The type of transducer used should be properly set before operating the equipment.
Select the type of transducer used as follows.
CHANGEOVER : AUTO MANUAL [FORE] XDR : N/A 50kHz 200kHz KEEL DIST. : 0.0 m(0.0-10.0) [AFT] XDR : N/A 50 kHz 200kHz KEEL DIST. : 0.0 m(0.0-10.0) DEPTH(BELOW) TRANSDUCER KEEL DISP MODE : DUAL SINGLE DISP ORDER*: AFT/FORE FORE/AFT OUTPUT* : FORE AFT MEMORIZE* : DUAL FORE AFT
* Does not appear when DISP MODE is set to SINGLE. 3. Set the transducer(s) as shown below. Use [▲] or [▼] to select an item and [+] or [-] to set option. a) CHANGEOVER sets how transducer(s) is connected to the FE-700. Select MANUAL for
connection via Distribution Box MB-1200.
on actual installation.
c) KEEL DIST sets the distance from transducer to keel of the ship.
indication below the transducer (except DBS mode), or KEEL for depth indication below the
keel.
e) DISP MODE sets the function of the MODE switch in case of dual frequencies. Select DUAL
to show the dual frequency display (fore and aft), or SINGLE to show single frequency
display.



f) DISP ORDER sets where to locate the fore and aft displays (right or left side) in the dual
frequency display.
g) OUTPUT sets what data to output to external equipment (in IEC/NMEA data format) in case
of dual frequencies. Select FORE to output FORE data, or AFT to output AFT data.
h) MEMORIZE sets the source (transducer) for data recording (depth, etc.) in case of dual
frequencies. Select DUAL, FORE or AFT as appropriate. DUAL records both FORE and AFT
data for 12 hours. FORE or AFT records respective data for 24 hours.

SYSTEM MENU 2 MENU SELECT 1 2 3 TIME ADJUST INTERNAL EXTERNAL DAY 1 MONTH JAN YEAR 2009 ( 2100) HOUR 0 (0 23) MINUTE 1 (0 59) SECOND 42 (0 59) 01 JAN 2009 00:01:06
: To select item - +: To set option Select other mode to exit.
System menu 2
month, year, hour, minute and second with [+] or [-] key. Select EXTERNAL to use time data
from equipment that outputs time in ZDA format. At TIME DIFFERENCE field, select AUTO
or MANUAL. MANUAL requires entry of time difference.
SYSTEM MENU 2
MENU SELECT 1 2 3 TIME ADJUST INTERNAL EXTERNAL TIME DIFFERENCE AUTO MANUAL
MENU SELECT 1 2 3 TIME ADJUST INTERNAL EXTERNAL TIME DIFFERENCE AUTO MANUAL TIME DIFF HOUR 0 (0~13) TIME DIFF MIN 0 (0~59) TIME DIFF SIGN - (0~59)
: To select item - +: To set option. Select other mode to exit.
: To select item - +: To set option. Select other mode to exit.
TIME ADJUST set to EXTERNAL TIME DIFFERENCE set to MANUAL



ᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐วޔਅᲑࠃࠅᲑߦઍࠊࠆㆊᷰ ᦼຠߢࠅޔߤߜࠄ߆߇ߞߡ߹ߔޕޓߥ߅ޔຠ⾰ߪᄌࠊࠅ߹ߖ
A-4
3 6; ↪ㅜ㧛⠨
6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1(6*'722'4 241&7%637#.+6;+56*'5#/'
(+:
%4+/210.7) (8 .(
5'.(6#22+0)5%4'9 :575
01 ဳ ฬ㧛ⷙᩰ
176.+0' ฬޓޓ⒓
⇛ޓޓ࿑
+056#..#6+10/#6'4+#.5
Ꮏ᧚ᢱ
㩎㩡㩇㩊㨹㩕㩩㩧㩒㩆㩨ޓ㩆㨷
⌕┵ሶ
ޓޓ
ࠎޕ
㧲㨁㧾㨁㧺㧻ޓ㧱㧸㧱㧯㨀㧾㧵㧯ޓ㧯㧻ޓ㧚㧘㧸㨀㧰 ():
ᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐วޔਅᲑࠃࠅᲑߦઍࠊࠆㆊᷰ ᦼຠߢࠅޔߤߜࠄ߆߇ߞߡ߹ߔޕޓߥ߅ޔຠ⾰ߪᄌࠊࠅ߹ߖ
A-3
6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1(6*'722'4 241&7%637#.+6;+56*'5#/'
3 6; ↪ㅜ㧛⠨
():
&7//;(+./ - 41*5
5'.(6#22+0)5%4'9 :575
01 ဳ ฬ㧛ⷙᩰ
176.+0' ฬޓޓ⒓
⇛ޓޓ࿑
㩎㩡㩇㩊㨹㩕㩩㩧㩒㩆㩨ޓ㩆㨷
ઃዻຠ
㩖㩨㩡㨼㩧㩎㩨㩖㨲㩣㩛 -
ࠎޕ





ᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐วޔਅᲑࠃࠅᲑߦઍࠊࠆㆊᷰ ᦼຠߢࠅޔߤߜࠄ߆߇ߞߡ߹ߔޕޓߥ߅ޔຠ⾰ߪᄌࠊࠅ߹ߖ
A-10
3 6; ↪ㅜ㧛⠨
6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1(6*'722'4 241&7%637#.+6;+56*'5#/'
#&:
%4+/210.7) (8 .(
%4+/210.7) (8/
5'.(6#22+0)5%4'9 :575
01 ဳ ฬ㧛ⷙᩰ
176.+0' ฬޓޓ⒓
⇛ޓޓ࿑
+056#..#6+10/#6'4+#.5
⌕┵ሶ
⌕┵ሶ
ࠎޕ
ᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐วޔਅᲑࠃࠅᲑߦઍࠊࠆㆊᷰ ᦼຠߢࠅޔߤߜࠄ߆߇ߞߡ߹ߔޕޓߥ߅ޔຠ⾰ߪᄌࠊࠅ߹ߖࠎޕ
㧲㨁㧾㨁㧺㧻ޓ㧱㧸㧱㧯㨀㧾㧵㧯ޓ㧯㧻ޓ㧚㧘㧸㨀㧰 #&:
6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1(6*'722'4241&7%6 37#.+6;+56*'5#/'
3 6; ↪ㅜ㧛⠨
4'/#4-5 ⇟ภ
#&:
5'.(6#22+0)5%4'9 :575
01 ဳ ฬ㧛ⷙᩰ
176.+0' ฬޓޓ⒓
⇛ޓޓ࿑
㩎㩡㩇㩊㨹㩕㩩㩧㩒㩆㩨㩆㨷
ઃዻຠ









































































Y. Hatai


Y. Hatai

Apr.28'06 T.MAtsuguchi

Apr.28'06 T.Matsuguchi


6 5 2 4 3
*4. USE A DISTRIBUTION BOX OR A MATCHING BOX WHEN TWO TRANSDUCERS ARE INSTALLED. *5. TRANSMIT FREQUENCY IS SET TO 200 kHz AT FACTORY. CHANGE THE SETTING FROM MENU FOR 50 kHz USE.
DC電源使用時要改造
TO USE DC SOURCE.
RELAY COMMON
*4)2台の送受波器を装備するときは、切換器または接続箱を使用すること。
NORMAL OPEN
EIA232-TD
EIA232-RD
7 8 TD1-A
TD1-B
9 RD1-A RD1-B 10
TD1-A
TD1-B
TD1-A
TD1-B
TB1
GND
TB3
GND
GND
TB5 DPYCYS-1.5 *1
TB6
U
1 2 3 4 5 6
1 2 3 4 5
6 7 8 9 10
P
P
P
P
P
P
*6. REFER TO FE-720 INTERCONNECTION DIAGRAM FOR DETAIL.
TPYCYS-1.5
DPYCYS-1.5 *1
*6)接続の詳細はFE-720相互結線図を参照のこと。
TTYCYS-4
TTYCYS-4
TTYCYS-4
PC (EIA-232C) OR PRINTER
PP-505-FE
100/110-115/ 200/220-230 VAC,
ALARM RELAY
NORMAL CLOSE/OPEN
パソコンまたはプリンタ
深度表示器
DEPTH INDICATOR
FE-720
または OR
航法装置
NAV EQUIPMENT
IEC61162-1
*3)工場にて取付済み。 *2)オプション。
*3. FITTED AT FACTORY. *2. OPTION.
*1. SHIPYARD SUPPLY.
注記
NOTE
A
B
D

02-129-10040 DIGITAL DEPTH INDICATOR
INTERCONNECTION DIAGRAM
IV-1.25sq. IV-2sq.
IV-1.25sq.
DIGITAL DEPTH
INDICATOR
FE-720
深度表示器
INDICATOR DIGITAL DEPTH
FE-720
深度表示器 FE-720
相互結線図
0V SHIELD
0V SHIELD
TD-A
TD-B
RD-A
RD-B
+24V
DIM-P
TD-A
TD-B
RD-A
RD-B
+24V
DIM-P
2 4 3 1
GND
GND
GND
GND
J7
J6
NC
NC
NC
J7
J6
NC
NC
NC
1 2 3 4 5 6
1 2 3 4 5 6
1 2 3 4 5 6
1 2 3 4 5 6
MJ-A6SPF *3
MJ-A7SPF
MJ-A6SPF
TITLE
名称
SCALE MASS NAME
WHT
BLU
YEL
GRN
RED
BLK
シロ WHT
クロ BLK
WHT
BLU
YEL
GRN
RED
BLK
シロ WHT
クロ BLK
ミドリ
ミドリ
シロ
アオ
アカ
クロ
シロ
アオ
アカ
クロ
キ
キ
FUSE(1A)
FUSE(1A)
*2 端子台箱
*2 端子台箱
FE-700
REF.No.
DS-802
TERMINAL BOX
DS-802
T.YAMASAKI Apr. 10 '07
Apr.17'07 R.Esumi
IV-2sq.
T.TAKENO Apr. 10 '07
1 2 3 4 5 6
1 2 3 4 5 6
DPYC-1.5 *1
DPYC-1.5 *1
24VDC DPYC-1.5 *1
調光器 DIMMER
U
L V *4
調光器 DIMMER
U
L V *4
U
V *2
MF22L-1/2-200V
U
MF22L-1/2-200V
APPROVED
CHECKED
DWG.No.
MF22L-1/2
DRAWN
*1 TTYCYS-4,30m MAX.
DIMMER
調光器
DIMMER
*1 TTYCYS-4,30m MAX.
*4. REMOVE RESISTANCE 3kΩ FOR USING 200V SET.
*1 IV-2sq.
P
P
P
P
P
1 2 3 4 5 6
9 RD1-A
RD1-B 10
1 2 3 4 5 6
NORMAL CLOSE
NORMAL OPEN
RELAY COMMON
EIA232-TD
EIA232-RD
GND
TD1-B
TD1-A
TD1-B
+24V
0V GND
TD1-A
TD1-B
+24V
GND
DISTRIBUTION BOX
分配箱
FE-702
*3)工場にて取付済み。
*3. FITTED AT FACTORY. *2. OPTION.
*1. SHIPYARD SUPPLY.
*2)オプション。
注記
NOTE
A
B

INTERCONNECTION DIAGRAM
相互結線図
PP-505-FE
プリンタ
PRINTER
08S0087,2m *1 IV-2sq.
名称
NAME
6 5 4 EIA232-TD
EIA232-RD
FE-702
GND
TB1 TPYCYS-1.5,MAX.10m
REF.No.
T.TAKENO
Jan. 5'07 R.Esumi
FM14-7P *1
MASS
Dec. 28 '06
Jan. 5 '07
APPROVED
DWG.No.
5 4 3 2 1
SCALE
J1
RXD(H)
TXD(H)
0V TXD(C)
RXD(C)
+12V
NC
PRINTER プリンタ
PP-505-FE
2 1 J2
FM14-2P *2
RED
BLK アカ
クロ 12-32 VDC
*3)コネクタケースでアースをとる。
*3: GROUND THRU CONNECTOR CLAMP.
*2: FITTED AT FACTORY. *1: SHIPYARD SUPPLY.
注記
NOTE
A
B