Page 1 of the Desa Tech PC3460LP user manual — — Installation and service must be performed by
Page 1 · click to enlarge
Page 1

DECORATIVE PATIO FIRE OWNER’S OPERATION AND INSTALLATION MANUAL

Desa Tech PC3460LP — DECORATIVE PATIO FIRE OWNER’S OPERATION AND INSTALLATION MANUAL diagram (page 1)
Fig. 1

Models PC4670LP and

®

PC3460LP

— Do not store or use gasoline or other flammable

vapors and liquids in the vicinity of this or any other appliance.

— WHAT TO DO IF YOU SMELL GAS

  • Do not try to light any appliance.
  • Do not touch any electrical switch; do not use any phone in your building.
  • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
  • If you cannot reach your gas supplier, call the fire department.

— Installation and service must be performed by

a qualified installer, service agency, or the gas supplier.

Your Decorative Patio Fire is designed for installation in a fully vented, open air patio area which is constructed of noncombustible materials.

Save this manual for future reference.

Page 2 of the Desa Tech PC3460LP user manual — WARNING ICON G 001 WARNINGS
Page 2 · click to enlarge
Page 2

SAFETY INFORMATION

  • 1. This appliance is only for use with the type of gas indicated on the rating plate. 2. Do not place propane supply tank(s) inside any structure. Locate propane/ LP supply tank(s) outdoors. If you are using propane/LP tanks of 100 lb. capacity or greater, keep appliance at least six feet away from tanks. If you are using a 20 lb. propane/LP tank commonly used with a gas grill, you must use the supplied tank securement bracket and strap to locate and secure tank. Keep propane/LP tank(s) below 100º F. 3. The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANS Z223.1, NFPA 58. 4. If you smell gas
  • shut off gas supply
  • do not try to light any appliance
  • do not touch any electrical switch
  • immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions
  • if you cannot reach your gas supplier, call the fire department 5. Keep the area around the appliance clear and free from combustible materials, gasoline, or other flammable vapors and liquids. 6. Do not place this appliance on grass or dirt. This may prevent proper safety venting. Only operate this appliance on a level, outdoor, noncombustible surface. 7. Do not operate this appliance directly on combustible surfaces such as a wooden deck or grass lawn. This could cause severe property damage. 8. Do not operate this appliance directly under combustible materials such as tree limbs. They could be damaged or set on fire. 9. Maintain proper clearance from combustible materials.
  • Never place this appliance directly on any combustible surface.
  • Make sure combustible materials are at least 20 feet above appliance. This includes tree limbs.
  • Make sure combustible materials are at least 4 feet from sides of appliance. 10. Do not install this product in even a partially enclosed area, such as a garage or underneath a patio cover or gazebo. They could be damaged or set on fire.

WARNING ICON G 001 WARNINGS

Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, or nausea. If you have these signs, the appliance may not be working properly. Get fresh air at once! Have appliance serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes.

Propane/LP Gas: Propane/LP gas is odor- less. An odor-making agent is added to the gas. The odor helps you detect a gas leak. However, the odor added to the gas can fade. Gas may be present even though no odor exists.

Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this appliance.

2 107497

Page 3 of the Desa Tech PC3460LP user manual — PRODUCT IDENTIFICATION
Page 3 · click to enlarge
Page 3

SAFETY INFORMATION (Continued)

23. Do not burn anything in this product. Ashes from trash or other combustibles could damage the burner system and affect its operation. Airborne ashes could set fires elsewhere and could cause se- vere burns or cause clothing to ignite. 24. Do not use appliance if any gas controls have been exposed to or under water. Im- mediately call a qualified service techni- cian to inspect the appliance and to replace any part of the control system and any gas control which has been under water. 25. Do not allow water to contact the lava rock or logs. Water from rain, sprin- klers, toys, horseplay, etc. can damage lava rock and logs. When heated, they may crack, break, or even explode. This could cause severe injury.

26. Do not leave appliance unattended while in operation. 27. Do not operate this product around in- toxicated people. They could injure them- selves or others when using this product. 28. Turn off gas at gas supply when this appliance is not in use. 29. Use protective cover (included) when appliance is not in use. Make sure ap- pliance is cool before using cover. 30. Turn appliance off and let cool before servicing or repairing. 31. Use only original replacement parts. This appliance must use design-specific parts. Do not substitute or use generic parts. Improper replacement parts could cause serious or fatal injuries.

11. Do not operate near combustible ma- terials such as vinyl or wood siding on a home or other structure. They could be damaged or set on fire. 12. Do not set combustibles on the edge of the appliance. Items such as paper cups, plates, and napkins could ignite. 13. Do not operate this appliance where ex- cessive wind or drafts are present. The open flame may be blown outside of the appliance area. This could burn adults or children and cause clothing to ignite. 14. Do not use appliance below ground level. Propane/LP gas is heavier than air. If a leak occurs, propane/LP gas will sink to the lowest possible level. 15. Locate gas hose away from areas where people may trip over it or where it could be accidentally damaged. 16. Check gas hose before each use. If hose shows excessive wear or damage, re- place hose assembly before operating appliance. See Cleaning and Mainte- nance on page 8 for how to inspect in- let hose. Use only the replacement hose listed in this manual. 17. Check burner before each use. If dam- aged, replace burner before operating appliance. Use only the replacement burner listed in this manual. 18. Do not block air inlets at the bottom edge of appliance base. 19. Only use accessories approved for use with this appliance. 20. Do not use charcoal starting fluid or any other combustible fluid to “help” ignite the fire. This could cause personal in- jury or death. 21. Do not burn solid fuel in this appliance. 22. Do not cook anything with this product. This includes hot dogs, marshmallows, hamburgers, or any other food. Debris from food could damage the burner sys- tem and affect its operation. Grease from food could flame up and cause severe burns or cause clothing to ignite.

PRODUCT IDENTIFICATION

3/8" Female Flare Tube Fitting (5/8"-18 Thread)

Hose/Regulator Assembly* (Vent Pointed Down)

Appliance Hose and Fitting

Tank Strap* Rear Tabs

3/8" Male Flare Tube Fitting (5/8"-18 Thread)

* For Use with Portable (20 lb.) Fuel Cylinder Cable Tie

Figure 1 - Product Identification

Show 8 more labels / short text on this page
Burner Ignitor Electrode · Thermocouple · Firepit · Gas Control Knob · Ignitor Button · Tank Securement Bracket* · Front Tabs · 3 107497
Page 4 of the Desa Tech PC3460LP user manual — UNPACKING
Page 4 · click to enlarge
Page 4

LOCAL CODES

INSTALLATION

HIGH ALTITUDE DERATE In the U.S.A., input BTU shall be derated 4% (1 orifice size) per 1,000 feet for altitudes above 2,000 feet. In Canada, input BTU shall be derated 10% (2 orifice sizes) at altitudes from 2,000 to 4,500 feet.

Install and use appliance with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code, ANS Z223.1, also known as NFPA 54* or NFPA 58, standard for the storage and handling of liquified petroleum gases.

*Available from:

LOCATING APPLIANCE

American National Standards Institute, Inc.

1430 Broadway New York, NY 10018

When locating this appliance, follow all safety information on pages 2 and 3.

National Fire Protection Association, Inc.

Do not use this appliance indoors. It is for outdoor use only. Do not locate this product in even a partially enclosed area, such as a garage or underneath a patio cover or ga- zebo. They could be damaged or set on fire.

Batterymarch Park Quincy, MA 02269

NOTICE: Installation, service, and repair of this appliance must be performed by a qualified installer, service agency, company, or gas supplier experienced with this type of gas appliance. Only factory au- thorized components listed in these instructions may be used in accor- dance with the manufacturer’s in- structions and all codes and re- quirements of the authority having jurisdiction. Any modifications to this appliance, or use of unautho- rized components or accessory items will void the manufacturer’s warranty, and may result in a haz- ardous condition.

UNPACKING

Locate this appliance on a level, outdoor, noncombustible surface. Do not place this appliance on grass or dirt. This may prevent proper safety venting. Do not operate where wind or excessive drafts are present.

  • Maintain proper clearance from combustible materials.
  • Never place this appliance directly on any combustible surface.
  • Make sure combustible materials are at least 20 feet above appliance. This includes tree limbs.
  • Make sure combustible materials are at least 4 feet from sides of appliance.
1. Remove lava rock and log pack from carton. 2. Carefully lift firepit out of carton and gently place at site of installation. 3. Check all items for any shipping damage. If damaged, promptly inform dealer where you bought the product.

CHECK GAS TYPE Use only propane/LP gas. If your gas supply is not propane/LP gas, do not install appliance. Call dealer where you bought appliance.

If your fuel source is a 20 lb. tank (com- monly used with gas grills), install tank securement bracket to concrete firepit be- fore installation (see Connecting to Portable 20 lb. Propane/LP Gas Supply, page 5).

  • Note: Deterioration or damage due to severe weather conditions such as hail, hurricanes, earthquakes, or tornadoes, or discoloration due to exposure to chemicals either directly or in the atmosphere, is not covered by the Limited Warranty on the back of this manual. The warranty also does not cover the following:
  • weather damage caused by not using the protective cover
  • chips, cracks, or breakage caused from dropping, dragging, or hitting firepit.
DECORATIVE GAS PATIO FIRE SPECIFICATIONS PROPANE/LP GAS: RATED PRESSURE*11.0" W.C. MINIMUM GAS PRESSURE*10.0" W.C MAXIMUM GAS PRESSURE*14.5" W.C. INTERNAL REG. SET POINT8.0" W.C. ORIFICE DRILL SIZE30 (.128") BTU/HR OUTPUT70,000 SHIPPING WEIGHT190 LBS.

You may paint your tank securement bracket so it will blend better with the surroundings. Before painting, clean the bracket with a degreasing cleanser.

Make sure to locate appliance where gas hose and propane/LP tank (if using 20 lb. portable tank) is out of traffic areas. This will help prevent people from tripping over the hose. This will also help prevent acci- dental damage to the hose.

The surface of the firepit naturally contains spaces, surface cracks, and variations in color and texture. The limited warranty does not cover such surface imperfections.

*Measured at entry of flexible supply hose.

4 107497

Page 5 of the Desa Tech PC3460LP user manual — Installation Items Needed
Page 5 · click to enlarge
Page 5

INSTALLATION Continued

6. Close cable tie, previously attached, around hose and pull firmly to secure. Cut off excess cable tie with scissors. 7. Slip the lighting and warning hang tags between the hose and tank bracket for easy reference. 8. Open supply valve on propane/LP tank slowly. Note: If not opened slowly, ex- cess flow check valve on propane/LP tank will stop gas flow. If this happens, close propane supply valve and open again slowly. 9. Check all connections for leaks. Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak. Correct all leaks at once. 10. Close propane/LP supply valve.

Connecting to Fixed Piping Gas Systems (100 lb. Tank or Larger)

CONNECTING TO GAS SUPPLY

Connecting to Portable 20 lb. Propane/LP Gas Supply

Installation Items Needed

  • Before installing appliance, make sure your installer has the items listed below.
  • piping (check local codes)
  • sealant (resistant to propane/LP gas) (May be pipe dope or Teflon tape)
  • equipment shutoff valve*
  • test gauge connection*
  • sediment trap
  • tee joint
  • pipe wrench
  • brass fitting(s) (depending upon gas supply plumbing)

Use the hose/regulator assembly, tank secure- ment bracket, tank strap, carriage bolt, wing nut, and cable tie supplied with your appliance. 1. Thread cable tie through 2 holes in bot- tom of tank securement bracket. Tie should be threaded from underneath bracket to be accessible when bracket is in position on the ground (see Figure 2). Do not close cable tie at this time. 2. Position the firepit and tank securement bracket as shown in Figure 2. Center the appliance hose and brass fitting be- tween the front tabs of securement bracket. Lift the firepit and slide the rear tabs of the bracket under the firepit. The front tabs of the bracket will remain on the outside of the firepit on either side of the appliance hose. 3. Set a filled 20 lb. propane/LP tank against the outside of the tank secure- ment bracket with the tank valve point- ing toward the firepit. Do not set the tank ON the bracket (see Figure 3). Wrap the tank strap around the tank so that the strap tabs are facing the firepit. Insert the carriage bolt through the strap tab with the square hole. Tighten wing nut securely onto bolt (see Figure 3). 4. Attach the hose/regulator assembly to the appliance hose brass fitting (see Fig- ure 3). Tighten firmly using a wrench. 5. Connect the POL fitting on the hose/ regulator assembly to propane/LP tank. Turn POL fitting counterclockwise to secure to tank. Tighten firmly using 7/8" wrench. IMPORTANT: Position regula- tor so that regulator vent is pointed down (see Figure 3). Pointing the vent down protects it from freezing rain or sleet.

Appliance Hose and Brass Fitting

* An CSA/AGA design-certified equipment shutoff valve with 1/8" NPT tap is an ac- ceptable alternative to test gauge connec- tion. Purchase the optional CSA/AGA de- sign-certified equipment shutoff valve from your dealer. See Accessory, page 11. Tank Securement Bracket

Figure 2 - Attaching Tank Securement Bracket and Cable Tie

Hose/Regulator Assembly (Regulator Vent Pointing Down)

20 lb. Propane/LP Tank

Appliance Hose and Brass Fitting

Figure 3 - Connecting Appliance to Portable 20 lb. Propane/LP Gas Tank

Show 13 more labels / short text on this page
Firepit · Rear Tabs · Front Tabs · Cable Tie · POL Fitting · Firepit · Wing Nut · Tank Securement Bracket · Tank Strap · Cable Tie · Carriage Bolt · Continued · 5 107497
Page 6 of the Desa Tech PC3460LP user manual — ON POSITION
Page 6 · click to enlarge
Page 6

INSTALLATION Continued

Two Stage External Regulator with Vent Pointing Down You must install a two stage external regu- lator. The two stage external regulator will reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incoming gas pressure, regulator damage could occur. Install two stage external regu- lator with the vent pointing down as shown in Figure 4. Pointing the vent down protects it from freezing rain or sleet.

Propane/LP Supply Tank (100 lb. or larger)

Pressure Testing Gas Supply Piping System (Fixed Piping System Only)

Figure 4 - Two Stage External Regulator with Vent Pointing Down

Test Pressures In Excess Of 1/2 PSIG (3.5 kPa) 1. The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psi (3.5 kPa). 2. Cap off open end of gas pipe where equipment shutoff valve was connected. 3. Pressurize supply piping system by ei- ther using compressed air or opening pro- pane/LP supply tank slowly. Note: If not opened slowly, excess-flow check valve on propane/LP tank will stop gas flow. If this happens, close propane/ LP supply valve and open again slowly. 4. Check all joints of gas supply piping system. Apply mixture of liquid soap and water to gas joints. Bubbles form- ing show a leak. 5. Correct all leaks at once. 6. Reconnect unit and equipment shutoff valve to gas supply. Check reconnected fittings for leaks.

Desa Tech PC3460LP — Pressure Testing Gas Supply Piping System (Fixed Piping System Only) diagram (page 6)
Fig. 2 · Pressure Testing Gas Supply Piping System (Fixed Pip…

From Two Stage External Regulator (10" W.C.** to 14.5" W.C. Pressure)

CSA/AGA Design- Certified Equipment Shutoff Valve With 1/8" NPT Tap*

Desa Tech PC3460LP — Pressure Testing Gas Supply Piping System (Fixed Piping System Only) diagram (page 6)
Fig. 3 · Pressure Testing Gas Supply Piping System (Fixed Pip…

Figure 5 - Gas Connection (When Using 100 lb. Tank or Larger)

If you are using a 100 lb. supply tank or larger, and a fixed piping system, installation must include an equipment shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from appliance (see Figure 5). IMPORTANT: Install equip- ment shutoff valve in an accessible location. The equipment shutoff valve is for turning on and shutting off the gas to the appliance.

* Purchase the optional CSA/AGA design- certified equipment shutoff valve from your dealer. See Accessory, page 11. ** Minimum inlet pressure for purpose of input adjustment.

CHECKING GAS CONNECTIONS

Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in a clogged burner injector.

Desa Tech PC3460LP — CHECKING GAS CONNECTIONS diagram (page 6)
Fig. 4

Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa) 1. The appliance must be isolated from the gas supply piping system by closing its individual equipment shutoff valve dur- ing any pressure testing of the gas sup- ply piping system at test pressures equal to or less than 1/2 psi (3.5 kPa).

We recommend that you install a sediment trap in supply line as shown in Figure 5. Locate sediment trap where it is within reach for cleaning. Install in piping system be- tween fuel supply and patio firepit. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap traps mois- ture and contaminants. This keeps them from going into appliance controls. If sediment trap is not installed or is installed wrong, appliance may not run properly.

Open Equipment Shutoff Valve

ON POSITION

OFF POSITION

Figure 6 - Equipment Shutoff Valve

Sediment Trap · Closed · 6 107497

Page 7 of the Desa Tech PC3460LP user manual — SETUP
Page 7 · click to enlarge
Page 7

INSTALLATION (Continued)

OPERATING APPLIANCE

2. Pressurize supply piping system by either using compressed air or opening propane/LP supply tank valve. 3. Check all joints from propane/LP supply tank to equipment shutoff valve (see Figure 7). Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak. 4. Correct all leaks at once.

FOR YOUR SAFETY

READ BEFORE

Place the six refractory logs on top of the lava rock. The arrangement is left to your personal preference. Try different place- ments to achieve your desired flame pattern.

LIGHTING

Pressure Testing Appliance Gas Connections (Fixed Piping System Only) 1. Open equipment shutoff valve (see Fig- ure 6, page 6). 2. Open propane/LP supply tank valve. 3. Check all joints from equipment shutoff valve to supply hose. Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak. 4. Correct all leaks at once.

BATTERY INSTALLATION

Your Comfort Glow Patio Fire uses an elec- tronic ignitor which requires one AA alka- line battery (not included). The battery com- partment is located in the ignitor module behind the ignitor button.

Propane/LP Supply Tank (100 lb. or larger)

To install the battery into the ignitor: 1. Locate the ignitor button on the con- trol panel (see Figure 8). 2. Rotate the ignitor button counterclock- wise to remove. 3. Install a fresh AA alkaline battery into the ignitor module, positive terminal first. 4. Replace button by rotating clockwise. Tighten finger tight. Do not over- tighten.

BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the ground because some gas is heavier than air and will settle on the ground.

Figure 7 - Checking Gas Joints

  • WHAT TO DO IF YOU SMELL GAS
  • Do not try to light any appliance.
  • Do not touch any electric switch; do not use any phone in your building.
  • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
  • If you cannot reach your gas supplier, call the fire department.

SETUP

Your Comfort Glow Patio Fire is designed to operate with lava rock piled in and around the burner, and refractory logs placed on top of the lava rock.

Desa Tech PC3460LP — SETUP diagram (page 7)
Fig. 5

Carefully pour supplied lava rock into basin to cover the burner. Be sure that the burner and burner ports are covered completely by lava rock to better disperse the flame and to create a more natural looking fire.

Figure 8 - Control Panel

Show 5 more labels / short text on this page
Equipment Shutoff Valve · Control Valve Location · Ignitor Button · Continued · 7 107497
Page 8 of the Desa Tech PC3460LP user manual — SERVICE HINTS
Page 8 · click to enlarge
Page 8

OPERATING APPLIANCE Continued

7. Set control valve knob to LOW, MED, or HI. Slightly depress knob before turning. 8. To shut off appliance, turn control valve knob clockwise to the OFF position.

BATTERY CHECK

The electronic spark ignitor operates on one alkaline AA battery (not included). The battery is located within the ignitor module behind the ignitor button. See Battery Installation, page 7, for replace- ment instructions. WARNING: Close equipment shutoff valve when appliance is not in use.

LIGHTING INSTRUCTIONS

Lighting Using the Electronic Spark Ignition System 1. Open equipment shutoff valve. 2. If you smell gas, STOP! Turn the equipment shutoff valve to OFF. Check gas connections for leaks. Do not continue until gas leaks are corrected. 3. After correcting leaks, wait five (5) minutes to clear out any gas. If you then smell gas, STOP! Follow the safety information in column 3, page 7. If you do not smell gas, go back to step 1. 4. Push in and hold the electronic spark ignitor button (see Figure 9). Note: You should be able to hear a rapid clicking sound from the burner bowl when the ignitor button is depressed. If you do not hear anything, see Bat- tery Check, and Troubleshooting, pages 9 and 10. 5. Slightly depress and turn control valve knob counterclockwise

CLEANING AND MAINTENANCE

Lighting Manually with a Match 1. Open equipment shutoff valve. 2. If you smell gas, STOP! Turn the equipment shutoff valve to OFF. Check gas connections for leaks. Do not continue until gas leaks are corrected. 3. Wait five (5) minutes to clear out any gas. If you then smell gas, STOP! Fol- low the safety information in column 3, page 7. If you do not smell gas, go back to step 1. 4. Light a match and lay it on top of the lava rock just above the burner.

Regularly check all burner ports for block- age. Burner ports are the small holes on top of the burner. Also check the ignitor port for blockage. This port is on the inside curve of the burner, pointed at the ignitor electrode. Also check the thermocouple port for block- age. This port is on the inside curve of the burner, pointed at the thermocouple. Clear blocked ports by gently inserting a small wire into the port.

Logs or lava rock may become coated with soot. If so, clean them using a bristle brush.

Check rubber supply hose periodically for signs of wear or damage. Check entire length of hose, including the portion inside the firepit pedestal. Check hose by carefully lifting the pedestal up to view the entire hose. If hose is damaged or worn, replace hose before next use. Use only original replacement parts. See Parts List on page 13 for service replacement parts.

5. Turn control valve knob counterclockwise to LOW (see Figure 9). Push in and hold control valve knob.

to LOW. Push in and hold control valve knob.

SERVICE HINTS

6. When burner lights, keep control valve button pushed in. Release button after 30 seconds. Note: If heater fails to ignite within 10 seconds, gas supply line may have air in it. If so, repeat steps 1 through 6. 7. Set control valve knob to LOW, MED, or HI. Slightly depress knob before turning. 8. To shut off appliance, turn control valve knob clockwise to the OFF position.
  • When Gas Pressure Is Too Low
  • burner may have delayed ignition
  • propane/LP gas supply may be low
6. When burner lights, release the ignitor button. Keep control valve button pushed in. Release button after 30 seconds. Note: If heater fails to ignite within 10 seconds, gas supply line may have air in it. If so, repeat steps 1 through 6.

When Gas Quality Is Bad • burner may backfire when lit

You may feel your gas pressure is too low or gas quality is bad. If so, contact you local propane/LP gas supplier.

Desa Tech PC3460LP — SERVICE HINTS diagram (page 8)
Fig. 6

Figure 9 - Ignitor Button and Control Valve

Control Valve · Ignitor Button · 8 107497

Page 9 of the Desa Tech PC3460LP user manual — POSSIBLE CAUSE REMEDY OBSERVED PROBLEM
Page 9 · click to enlarge
Page 9

TROUBLESHOOTING WARNING: Turn off appliance and let cool before servicing. Only a qualified service person should service and repair appliance.

POSSIBLE CAUSE REMEDY OBSERVED PROBLEM

When ignitor button is pressed, there is no spark at burner

1. Ignitor electrode not connected to ignitor cable 2. Ignitor cable pinched or wet
1. Reconnect ignitor cable
2. Free ignitor cable if pinched by any metal or tubing. Keep ignitor cable dry 3. Replace ignitor cable 4. Replace electronic ignitor 5. Replace electrode 6. Reposition electrode 7. Replace batteries 8. Reattach ground wire to ignitor
3. Broken ignitor cable 4. Bad electronic ignitor 5. Ignitor electrode broken 6. Ignitor electrode positioned wrong 7. Batteries are dead or missing 8. Ground wire not attached

When ignitor button is pressed, there is spark at burner but no ignition

1. Gas supply turned off or equipment shutoff valve closed 2. Control knob not in LOW/START position 3. Control knob not pressed in while in LOW/START position 4. Air in gas lines when installed
1. Turn on gas supply or open equipment shutoff valve 2. Turn control knob to LOW/START position 3. Press in control knob while in LOW/ START position 4. Continue holding down control knob. Repeat igniting operation until air is removed 5. Check for proper supply pressure 6. Refill supply tank
5. Low gas pressure 6. Low fuel supply

Burner lights but flame goes out when con- trol knob is released

1. Control knob not fully pressed in 2. Control knob not pressed in long enough
1. Press in control knob fully 2. After burner lights, keep control knob pressed in 30 seconds 3. Fully open equipment shutoff valve 4. A) Contact local propane/LP gas company
3. Equipment shutoff valve not fully open 4. Burner flame not touching thermocouple, which allows thermocouple to cool, causing burner to go out. This problem could be caused by one or both of the following: A) Low gas pressure B) Dirty or partially clogged burner ports 5. Thermocouple connection loose at control valve 6. Thermocouple damaged 7. Control valve damaged

B) Clean burner ports (see Cleaning and Maintenance, page 8) or replace burner assembly

5. Hand tighten until snug, then tighten 1/4 turn more 6. Replace thermocouple 7. Replace control valve

Burner flame is too low or too high

1. Incorrect gas supply or pressure 2. Blocked burner orifice or burner manifold ports
1. Check for proper gas supply pressure 2. Free burner orifice and manifold ports of any burrs, lava rock particles, or other blockage 3. Verify proper burner orifice sizing (see specification chart, page 4)
3. Improper burner orifice size

www.desatech.com

Continued · 9 107497

Page 10 of the Desa Tech PC3460LP user manual — OBSERVED PROBLEM
Page 10 · click to enlarge
Page 10

TROUBLESHOOTING Continued

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Delayed ignition of burner

1. Manifold pressure is too low 2. Burner orifice or burner manifold ports clogged
1. Contact local propane/LP gas company 2. Clean burner (see Cleaning and Maintenance , page 8) or replace burner orifice

Burner backfiring during combustion

1. Burner orifice or burner manifold ports clogged or damaged 2. Damaged burner 3. Gas control defective
1. Clean burner (see Cleaning and Maintenance , page 8) or replace burner orifice 2. Replace damaged burner 3. Replace gas control

Fireplace produces a clicking/ticking noise just after burner is lit or shut off

1. Lava rock, refractory logs, or metal parts expanding while heating or contracting while cooling
1. This is common with most heaters. If noise is excessive, contact qualified service person

Fireplace produces unwanted odors

1. Gas leak. See Warning statement at bottom of page 2. Low fuel supply
1. Locate and correct all leaks (see Checking Gas Connections , page 6) 2. Refill supply tank

Gas odor even when control knob is in OFF position

1. Gas leak. See Warning statement at bottom of page 2. Control valve defective
1. Locate and correct all leaks (see Checking Gas Connections , page 6) 2. Replace control valve

Gas odor during combustion

1. Gas leak. See Warning statement at bottom of page
1. Locate and correct all leaks (see Checking Gas Connections , page 6)
1. Sooting on the logs is natural
1. Clean soot with a soft bristle brush
  • WARNING: If you smell gas
  • Shut off gas supply.
  • Do not try to light any appliance.
  • Do not touch any electrical switch; do not use any phone near fireplace
  • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
  • If you cannot reach your gas supplier, call the fire department.

www.desatech.com

Soot on logs · 10 107497

Page 11 of the Desa Tech PC3460LP user manual — EQUIPMENT SHUTOFF VALVE - GA5010
Page 11 · click to enlarge
Page 11

PARTS CENTRALS These Parts Centrals are privately-owned businesses. They have agreed to support our customer’s needs by providing original replacement parts and accessories. REPLACEMENT PARTS

Baltimore Electric 1348 Dixwell Avenue Hamden, CT 06514-0322 1-800-397-7553 203-248-7553 Parts Department

Dayton Hardware P.O. Box 275 North Dayton Station Dayton, OH 45404-0275 All States 937-258-3721 OH 1-800-762-3426 Parts Department

PARTS UNDER WARRANTY

Contact authorized dealers of this product or Parts Central. If they can’t supply original replacement part(s), call DESA International’s Technical Service Department at 1-800-DESA LOG (1-800-337-2564).

Portable Heater Parts 342 N. County Rd. 400 E. Valparaiso, IN 46383-9704 All States 219-462-7441 1-800-362-6951 Parts Department sales@portableheaterparts.com techservice@portableheaterparts.com

Halco Enterprises 208 Carter Drive, Unit 21 West Chester, PA 19382-4500 610-430-7717 1-800-368-0803 Parts Department www.halcoenterprises.com

  • When calling DESA International, have ready
  • your name
  • your address
  • model and serial numbers of your appliance
  • how appliance was malfunctioning
  • type of gas used (propane/LP or natural gas)
  • purchase date

FBD 1349 Adams St. Bowling Green, KY 42103-3414 270-846-1199 1-800-654-8534 Fax: 1-800-846-0090 franktalk@aol.com

Laportes Parts and Service 2444 N 5th Street Hartsville, SC 29550-7704 803-332-0191 Parts Department

Usually, we will ask you to return the defec- tive part to the factory.

PARTS NOT UNDER WARRANTY

Cans Unlimited, Inc. P.O. Box 645 Taylor, SC 29687-0013 All States 803-879-3009 1-800-845-5301 Parts Department cuisales@aol.com

Contact authorized dealers of this product or Parts Central. If they can’t supply origi- nal replacement part(s), call DESA International’s Parts Department at 1-800- 972-7879 for referral information.

Master Parts Distributor 1251 Mound Ave. NW Grand Rapids , MI 49504-2672 616-791-0505 1-800-446-1446 Fax: 1-616-791-8270 Parts Department www.nbmc.com

  • When calling DESA International, have ready
  • model number of your fireplace
  • the replacement part number

Heater and Fireplace Store 58 Halbe Lane Cape May Court, NJ 08210-1110 609-390-1100 Parts Department

Washer Equipment Co. 1715 Main Street Kansas City, MO 64108-2195 KS, MO, AR 816-842-3911 Parts Department www.washerparts.com

ACCESSORY

Purchase these fireplace accessories from your local dealer. If they can not supply these accessories, call DESA International’s Sales Department at 1-800-432-2382 for information. You can also write to the ad- dress listed on the back page of this manual.

TECHNICAL SERVICE

East Coast Energy Products 707 Broadway W. Long Branch, NJ 07764-1542 732-870-8809 1-800-755-8809 Parts Department www.njplaza.com/ecep

You may have further questions about in- stallation, operation, or troubleshooting. If so, contact DESA International’s Technical Service Department at 1-800-DESA LOG (1-800-337-2564).

EQUIPMENT SHUTOFF VALVE - GA5010

You can also visit DESA International’s technical service web site at www.desatech.com.

For all models. Equipment shutoff valve with 1/8" NPT tap. Fits 1/2" NPT pipe.

11 107497

Page 12 of the Desa Tech PC3460LP user manual — PATIO FIRE PC4670LP PC3460LP
Page 12 · click to enlarge
Page 12

ILLUSTRATED PARTS BREAKDOWN

Desa Tech PC3460LP — ILLUSTRATED PARTS BREAKDOWN diagram (page 12)
Fig. 7

PATIO FIRE PC4670LP PC3460LP

( NoteAppearance of firepit may vary depending on model.)

12 107497

Page 13 of the Desa Tech PC3460LP user manual — PARTS AVAILABLE — NOT SHOWN
Page 13 · click to enlarge
Page 13

PARTS LIST This list contains replaceable parts used in your appliance. When ordering parts, follow the instructions listed under Replacement Parts on page 11 of this manual. PATIO FIRE PC4670LP PC3460LP

KEY PART NO. PART NO. NO. FOR PC4670LP FOR PC3460LP DESCRIPTION QTY.

1 106116-02 106116-02 Burner Assembly 1 2 106117-01 106117-01 Burner Plate 1 3 106118-01 106118-01 Burner Plate Bracket 4 4 106051-01 106051-01 Injector, LP 1 5 106193-01 106193-01 Outlet Tube Assembly 1 6 102367-01 102367-01 Gas Valve 1 7 098508-01 098508-01 Nut, Valve Retention 2 8 098276-01 098276-01 Valve, Cap 1 9 099393-03 099393-03 Valve Knob 1 10 106137-01 106137-01 Thermocouple 1 11 106122-01 106122-01 T-C Bracket, LP 1 12 106711-01 106711-01 T-C Cover 1 13 106120-01 106120-01 Front Mounting Plate 1 14 106121-01 106121-01 Control Bracket 1 15 106130-01 106130-01 Spark Module 1 16 106715-01 106715-01 Grounding Wire Assembly 1 17 106134-01 106134-01 Electrode Assembly 1 18 107215-01 106123-01 Firepit 1 19 M10908-14 M10908-14 Screws, Sheet Metal 18 20 M11084-38 M11084-38 Screw, #8 x .38 2 21 101628-01 101628-01 Inlet Tube 1 22 106712-01 106712-01 Supply Hose 1 23 098867-03 098867-03 Pressure Regulator 1 24 097809-02 097809-02 Reg. Inlet Fitting 1 25 097809-02 097809-02 Reg. Outlet Fitting 1 26 106718-01 106718-01 Hose Clamp 1 27 107488-01 107488-01 Tank Securement Bracket 1 28 107489-01 107489-01 Tank Strap 1 29 107487-01 107487-01 Hose/Regulator Assembly 1 30 100919-01 100919-01 Wing Nut 1 31 100918-01 100918-01 1/4-20 Carriage Bolt 1 32 19724000 19724000 Cable Tie 1

PARTS AVAILABLE — NOT SHOWN

106204-01 106204-01 Lava Rock 1 106046-01 106046-01 Logs (Set of 6) 1 106717-02 106717-01 Protective Cover 1 107354-01 107354-01 Lighting Instructions Plate 1 107354-02 107354-02 Warning & Rating Plate 1

13 107497

Page 14 of the Desa Tech PC3460LP user manual — NOT A UPC
Page 14 · click to enlarge
Page 14

KEEP THIS WARRANTY WARRANTY INFORMATION

Serial No.

Always specify model and serial numbers when communicating with the factory.

We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied.

LIMITED WARRANTY COMFORT GLOW VENTED GAS PATIO FIRE

DESA International warrants this product to be free from defects on the firepit for five (5) years and all other parts for three (3) years from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions. To make a claim under this warranty the Bill of Sale or cancelled check must be presented.

This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required to restore this appliance to proper operating condition and an allowance for labor when provided by a DESA Authorized Service Center. Warranty part(s) MUST be obtained through authorized dealers of this product and/or DESA International who will provide original factory replacement parts. Failure to use original factory replacement parts voids this warranty. The appliance MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit.

This warranty does not apply to parts that are not in original condition because of normal wear and tear, or parts that fail or become damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation. Travel, diagnostic cost, labor, transportation and any and all such other costs related to repairing a defective appliance will be the responsibility of the owner.

TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURA- TION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO FIVE (5) YEARS ON FIREPIT AND THREE (3) YEARS ON ALL OTHER PARTS FROM THE DATE OF FIRST PURCHASE; AND DESA INTERNATIONAL’S LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND DESA INTERNATIONAL SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES.

Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or consequential damages, so the above limitation on implied warranties, or exclusion or limitation on damages may not apply to you.

This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.

For information about this warranty write:

INTERNATIONAL

2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004 www.desatech.com

107497-01 Rev. A 05/00

NOT A UPC

Model · Date Purchased · 107497 01

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Desa Tech PC3460LP

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Desa Tech PC3460LP

Be the first to ask — other owners or our team will answer.

Original document

Desa Tech PC3460LP manual PDF

14 pages·287 KB·Patio Heater·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…