OWNER’S OPERATION AND INSTALLATION MANUAL
AND EFP33PR GAS FIREPLACE
WITH TOTAL
CONTROL SYSTEM (TCS)
cabinet mantel, hearth base, and trim
accessories.
vapors and liquids in the vicinity of this or any other appliance. — WHAT TO DO IF YOU SMELL GAS
fied installer, service agency, or the gas supplier.
This appliance may be installed in an aftermarket*, permanently located, manufactured (mobile) home, where not prohibited by state or local codes. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.
Save this manual for future reference.
Shown with optional

Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.
Do not place clothing or other flammable material on or near the appliance. Never place any objects on the heater.
Fireplace front and screen be- comes very hot when running fireplace. Keep children and adults away from hot surfaces to avoid burns or clothing ignition. Fireplace will remain hot for a time after shutdown. Allow sur- faces to cool before touching.
Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, or nausea. If you have these signs, the fireplace may not be working properly. Get fresh air at once! Have fireplace serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes.
Carefully supervise young chil- dren when they are in the room with heater. When using the hand- held remote accessory, keep se- lector switch in the OFF position to prevent children from turning on burners with remote.
You must operate this fireplace with the fireplace screen and hood in place. Make sure fire- place screen and hood are in place before running fireplace.
Propane/LP Gas: Propane/LP gas is odor- less. An odor-making agent is added to the gas. The odor helps you detect a gas leak. How- ever, the odor added to the gas can fade. Gas may be present even though no odor exists.
Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this fireplace.
Keep the appliance area clear and free from combustible materials, gasoline, and other flammable vapors and liquids.
2 107570

LOCAL CODES
Install and use fireplace with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code, ANS Z223.1, also known as NFPA 54*.
*Available from:
American National Standards Institute, Inc.
1430 Broadway New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park Quincy, MA 02269
1. With utility knife, cut the carton all the way around above the staples on the bottom tray. Lift the carton off the heater. Remove packing. Note: The hood is located in the packing on the right hand side of the fireplace. Lift the fireplace off the bottom tray. 2. Locate two screws above top corners of the fireplace screen. Remove and discard these screws. Lift fireplace screen up and pull out to remove. 3. Remove protective packaging applied to logs, fireplace floor assembly, and fireplace. 4. Check all items for any shipping dam- age. If damaged, promptly inform dealer where you bought fireplace.
Manual Ignition Bypass Switch
Figure 1 - Fireplace Floor Assembly (EFP33PR Shown)
Figure 2 - Fireplace

AIR FOR COMBUSTION AND VENTILATION
buildings of unusually tight construction, you must provide additional fresh air.
Unusually tight construction is de- fined as construction where: a. walls and ceilings exposed to the outside atmosphere have a con- tinuous water vapor retarder with a rating of one perm (6 x 10-11 kg per pa-sec-m2) or less with open- ings gasketed or sealed and b. weather stripping has been added on openable windows and doors and c. caulking or sealants are applied to areas such as joints around window and door frames, be- tween sole plates and floors, be- tween wall-ceiling joints, be- tween wall panels, at penetra- tions for plumbing, electrical, and gas lines, and at other openings. If your home meets all of the three criteria above, you must provide ad- ditional fresh air. See Ventilation Air From Outdoors, page 6. If your home does not meet all of the three criteria above, proceed to Deter- mining Fresh-Air Flow for Fireplace Location on page 5.
This vent-free fireplace is clean burning. It requires no outside venting. There is no heat loss out a vent or up a chimney. Heat is generated by realistic flames. When used without the blower in “manual ignition” mode, the fireplace requires no electricity to operate, making it ideal for emergency backup heat.
This fireplace has a pilot with an Oxygen Depletion Sensing (ODS) safety shutoff sys- tem. The ODS/pilot is a required feature for vent-free room heaters. The ODS system shuts off the fireplace if there is not enough fresh air.
Today’s homes are built more energy effi- cient than ever. New materials, increased insulation, and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in. During heating months, home owners want their homes as airtight as possible.
This fireplace has a piezo ignitor. This sys- tem requires no matches, batteries, or other sources to light fireplace. The piezo ignition may be used to light the pilot and burner in the event of an electrical power outage (see Operating Fireplace, pages 21 and 22).
While it is good to make your home energy efficient, your home needs to breathe. Fresh air must enter your home. All fuel-burning appliances need fresh air for proper com- bustion and ventilation.
Exhaust fans, fireplaces, clothes dryers, and fuel burning appliances draw air from the house to operate. You must provide ad- equate fresh air for these appliances. This will insure proper venting of vented fuel- burning appliances.
This fireplace accepts an optional blower assembly. The GA3750 blower has a manual variable control. The GA3650T blower op- erates thermostatically. The blower circu- lates heated air from the fireplace into the room. Use of blower is optional. See Acces- sories, page 34.
The National Fuel Gas Code, ANS Z223.1 defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances in- stalled in that space. Rooms communicating directly with the space in which the appli- ances are installed*, through openings not furnished with doors, are considered a part of the unconfined space.
The following are excerpts from National Fuel Gas Code, NFPA 54/ANS Z223.1, Sec- tion 5.3, Air for Combustion and Ventilation.
All spaces in homes fall into one of the three following ventilation classifications: 1. Unusually Tight Construction 2. Unconfined Space 3. Confined Space
This fireplace features an infra-red wireless remote control. This control system can be used to automatically light the pilot and adjust the burner flame height at the push of a button.
The information on pages 4 through 6 will help you classify your space and provide adequate ventilation.
This heater shall not be installed in a con- fined space of unusually tight construction unless provisions are provided for adequate combustion and ventilation air.
This fireplace features a two-button wall switch and wall plate with glowing LED’s. The wall switch performs the same func- tions as the wireless hand-held remote con- trol with the added feature of LED’s for visual feedback of operation and status.
The air that leaks around doors and win- dows may provide enough fresh air for combustion and ventilation. However, in
* Adjoining rooms are communicating only if there are doorless passageways or ventila- tion grills between them.
4 107570

Use this work sheet to determine if you have a confined or unconfined space.
Space: Includes the room in which you will install fireplace plus any adjoining rooms with doorless passageways or ventilation grills between the rooms. 1. Determine the volume of the space (length x width x height). Length x Width x Height = cu. ft. (volume of space) Example: Space size 22 ft. (length) x 18 ft. (width) x 8 ft. (ceiling height) = 3168 cu. ft. (volume of space) If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these rooms to the total volume of the space. 2. Divide the space volume by 50 cubic feet to determine the maximum Btu/Hr the space can support.
(volume of space) ÷ 50 cu. ft. = (Maximum Btu/Hr the space can support) Example: 3168 cu. ft. (volume of space) ÷ 50 cu. ft. = 63.3 or 63,300 (maximum Btu/Hr the space can support) 3. Add the Btu/Hr of all fuel burning appliances in the space. Vent-free fireplace Btu/Hr Gas water heater* Btu/Hr Gas furnace Btu/Hr Vented gas heater Btu/Hr Gas fireplace logs Btu/Hr Other gas appliances* + Btu/Hr Total = Btu/Hr * Do not include direct-vent gas appliances. Direct-vent draws combustion air from the outdoors and vents to the outdoors. 4. Compare the maximum Btu/Hr the space can support with the actual amount of Btu/Hr used.
Btu/Hr (maximum the space can support) Btu/Hr (actual amount of Btu/Hr used) Example: 63,300 Btu/Hr (maximum the space can support)
73,000 Btu/Hr (actual amount of Btu/Hr used)
The space in the above example is a confined space because the actual Btu/Hr used is more than the maximum Btu/Hr the space can support. You must provide additional fresh air. Your options are as follows: A. Rework work sheet, adding the space of an adjoining room. If the extra space provides an unconfined space, remove door to adjoin- ing room or add ventilation grills between rooms. See Ventilation Air from Inside Building, page 6. B. Vent room directly to the outdoors. See Ventilation Air from Outdoors, page 6. C. Install a lower Btu/Hr fireplace, if lower Btu/Hr size makes room unconfined.
If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support, the space is an unconfined space. You will need no additional fresh air ventilation.
Continued · 5 107570


This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must pro- vide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 3). You can also remove door into adjoining room (see op- tion 3, Figure 3). Follow the National Fuel Gas Code NFPA 54/ANS Z223.1, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.
Figure 3 - Ventilation Air from Inside Building

Provide extra fresh air by using ventilation grills or ducts. You must provide two per- manent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces. Follow the National Fuel Gas Code NFPA 54/ANS Z223.1, Section 5.3, Air for Combustion and Ventilation for required size of ventila- tion grills or ducts.
Figure 4 - Ventilation Air from Outdoors
Outlet Air · 6 107570

Note: Your Comfort Glow fireplace is de- signed to be used in zero clearance installa- tions. Wall or framing material can be placed directly against any exterior surface on the rear, sides, or top of your fireplace, except where standoff spacers are integrally at- tached. If standoff spacers are attached to your fireplace, these spacers can be placed directly against wall or framing materials.
NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your pri- mary heating system. Do not in- stall this heater as your primary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circu- late the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source.
Carefully follow the instructions below. This will ensure safe installation.
Use the dimensions shown for rough open- ings to create the easiest installation (see Built-In Fireplace Installation, pages 17 and 18).
Minimum Clearances For Side Combustible Material, Side Wall, and Ceiling A. Clearances from the side of the fire- place cabinet to any combustible ma- terial and wall should follow diagram in Figure 5. Example: The face of a mantel, book- shelf, etc. is made of combustible ma- terial and protrudes 3 1/2" from the wall. This combustible material must be 4" from the side of the fireplace cabinet (see Figure 5). B. Clearances from the top of the fireplace opening to the ceiling should not be less than 42 inches.
Use only propane/LP gas. If your gas supply is not propane/LP gas, do not install fire- place. Call dealer where you bought fire- place for proper type fireplace.
This fireplace normally operates under 120 VAC/60 Hz line voltage. The electrical cord supplied with your fireplace is five feet in length. You must locate fireplace within reach of a 120 volt grounded electrical out- let. If not, you must install an electrical outlet within reach of the fireplace power cord. The GA3555 outlet accessory may be used for built-in applications.
*Minimum 16 inches from Side Wall
Figure 5 - Minimum Clearance for Combustible to Wall
Example · * · 7 107570

After unpacking fireplace (see UNPACK- ING, page 3), we suggest that you install your fireplace system in the following sequence: 1. Removal of fireplace floor assembly (required) 2. Electrical connections for power cord (required) 3. Relocating wall switch (optional) 4. Installing blower accessory (optional) 5. Connecting fireplace to gas supply (required) 6. Checking gas connections (required) 7. Firebox installation, conventional or built-in (required) 8. Installing brass perimeter trim (op- tional) 9. Installing fireplace hood (required) 10. Installing logs (required) 11. Installing fireplace screen (required)
Hole in Floor Support Bracket
Hole in Outer Casing
Screws Fireplace Floor Assembly
Figure 7 - Routing Power Cord
For Recessed Installation If an outlet is not installed in fireplace, install model GA3555 - Outlet Kit with Cover. This kit will supply a convenient 3- prong grounded electrical outlet for power. Refer to installation manual provided with this optional accessory for instructions on wiring. Note: A qualified installer must make all electrical connections.
Figure 6 - Removing Fireplace Floor Assemlby
This fireplace operates on 120 VAC, 60 Hz power. An electrical power cord is supplied with this unit.
Use the following instructions to complete each step.
For Mantel Installation 1. Determine from which side of the fire- place the power cord will exit. Locate the 1.5" diameter hole near the center of floor support bracket on appropriate side of lower cavity (see Figure 7). 2. Locate power cord. Remove wire tie or tape holding plug end of power cord. 3. Power cord has 2 plastic hole bushings threaded onto it. Route cord's 3-prong plug through the 1.5" diameter hole in appropriate floor support bracket. 4. Push first plastic bushing completely through hole. Squeeze bushing as needed to do this. 5. Install the second plastic bushing into the hole in the floor support bracket by snapping into place. 6. Route the 3-prong plug through the 1.5" hole in fireplace outer casing. 7. Install the first plastic bushing into this hole by snapping into place.
REMOVAL OF FIREPLACE SCREEN AND FLOOR ASSEMBLY
The push-button switch and decorative wall plate assembly supplied with your fireplace is pre-mounted at the factory in the lower cavity of the fireplace. You may relocate this switch/plate assembly to a more convenient location such as the side of your mantel or directly onto the wall near the fireplace. To mount the wall switch/plate assembly, you must first cut openings in the mantel or wall where the switch will be located.
1. Remove fireplace screen. Remove two screws that hold fireplace screen in place for shipping. These screws are located near top of screen. Discard screws. Lift fireplace screen up and pull out to remove. 2. If logs are installed, carefully remove the logs and set aside, noting the prop- erly mounted location of each. 3. Remove screws that attach fireplace floor assembly to fireplace. Open lower louver door. Carefully lift up fireplace floor assembly and remove from fireplace, taking care to pull flex- ible gas line through the access holes (see Figure 6). Note: Be careful of all wires on underside of log base.

10. Using a straight edge and pencil, con- nect the outer edges of the 4 holes for the rectangle (see Figure 10). This will give you cutting lines for the rectangle you will cut in the wall. 11. Using a keyhole saw, hack saw blade, drill, file, or other suitable tool, carefully cut out the rectangular opening. Note: The corners of the rectangle may be round. IMPORTANT: Do not exceed the size of the rectangle on template. 12. From inside the recessed opening for the fireplace, carefully pass switch/ plate assembly through the rectangu- lar opening to the outside of the wall. 13. Using wall anchors supplied in hard- ware package, fold wall anchor as shown in Figure11. 14. Insert wall anchor, wings first, into hole. Tap anchor flush to wall. 15. For thin walls (1/2" or less), insert red key into wall anchor. Push red key to “pop” open anchor wings. See Figure 14. IMPORTANT: Do not hammer key! For thick walls (over 1/2" thick), do not pop open wings.
Switch with Wall Plate
Figure 8 - Relocating Switch and Wall Plate
For Recessed Installation If fireplace is to be recessed into a wall (see Built-In Fireplace Installation, pages 17 and 18), we recommend mounting wall switch to left side of fireplace. The wall switch should be mounted approximately 12" from left edge of fireplace, and less than 60" from the floor. IMPORTANT: Do not locate wall switch directly in front of wall stud - there must be room behind wall board for wires from switch. If you choose to locate wall switch to right side of fireplace, the length of the cord restricts you to less than 6" from right edge of fireplace and less than 48" from floor.
Hole in Outer Casing
Make Marks at Centers of Holes
For Mantel Installation If fireplace is to be installed into a mantel, (see Conventional Fireplace Installation, pages 16 and 17) the wall switch may be mounted on either side of the mantel, facing to the side. Do not locate wall switch any- where on the front face of the mantel.
Hole in Floor Support Bracket
3/8" Diameter 2 Holes
4 3/4"
3 3/4"
Wall Switch/ Plate Assy
Figure 9 - Routing Wall Switch/Plate Through Fireplace for Relocation
Figure 10 - Using Template for Wall Switch Installation
Mounting Wall Switch to Wall for Re- cessed Fireplace 7. Create three openings on wall accord- ing to Template 1, page 35. This is best done by making a pattern to work with on your wall. Carefully cut page 35/36 from manual and tape paper template vertically onto wall at preferred location. Pierce the paper at the centers of the 2 holes with a nail or sharp pencil, leav- ing a mark on the wall. Do the same at centers of the four circles near the cor- ners of the rectangle. 8. Remove paper template from wall. 9. Drill 3/8" holes at each mark.
Figure 11 - Folding Anchor
Figure 12 - Popping Open Anchor Wings for Thin Walls

10. Using a straight edge and pencil, con- nect the outer edges of the 4 holes for the rectangle (see Figure 10, page 9). This will give you cutting lines for the rectangle you will cut in the mantel wall. 11. Using a keyhole saw, hack saw blade, drill, file, or other suitable tool, carefully cut out the rectangular opening. Note: The corners of the rectangle may be round. IMPORTANT: Do not exceed the size of the rectangle on template. 12. Carefully pass switch/plate assembly through rectangular opening from in- side mantel (see Figure 13). 13. Position switch/plate assembly vertically over opening with decal lettering upright. Make sure wires freely pass through wall without binding. Align holes in wall plate with 1/8" pilot holes in mantel wall. 14. Drive mounting screws, removed in step 2 of Relocating Wall Switch on page 9, through wall plate holes and into pilot holes in mantel wall. 15. Tighten screws until wall plate is firmly attached to mantel. Do not overtighten.
Lower Rear Wall of Firebox

Screw Green Ground Wire
Figure 13 - Securing Wall Switch
Figure 14 - Mounting Blower to Firebox
Mounting Wall Switch to Side of Mantel 7. Create three openings in the mantel wall according to Template 2, page 35. This is best done by making a pattern to work with on the mantel. Carefully cut page 35/36 from manual and tape paper tem- plate vertically onto mantel wall at pre- ferred location. Pierce the paper at the centers of the 2 holes with a nail or sharp pencil, leaving a mark on the wall. Do the same at centers of the four circles near the corners of the rectangle. 8. Remove paper template from mantel wall. 9. Drill 1/8" pilot holes at each mark for top and bottom screw holes. Drill 3/8" holes at each mark for centers of four circles near corners of rectangle.
Left Floor Support Bracket
1. If fireplace screen and floor are still installed, see Removing Fireplace Screen and Floor Assembly, page 8. 2. Attach the power cord to the blower motor by firmly pushing the two female termi- nals at the end of the power cord onto the two spade terminals on the blower motor. 3. Attach green ground wire from power cord to blower housing using screw provided (see Figure 14). Tighten screws securely. 4. Place the blower against lower rear wall of firebox outer wrapper with the ex- haust port directed upward. Align the holes in top mounting tabs of blower with holes in wall of wrapper (see Fig- ure 14). Using 2 screws provided, mount blower and tighten screws securely.
Figure 15 - Attaching Speed Control to Firebox

as a freestanding unit with an ac- cessory mantel, determine whether the power cord will exit the left side or the right side of the firebox. In- stall 1 plastic bushing provided into the 1.5" hole in the floor support bracket on the exit side (see Figure 16). Install the second plastic bush- ing provided into the 1.5" hole in the outer casing through which the power cord will exit. Route power cord through both plastic bushings and plug the power cord into a prop- erly grounded 3-prong wall recep- tacle near the firebox. b. If your fireplace system installation
10. Peel off backing paper and stick supplied wiring diagram decal near center of fire- box bottom (Figure 17). 11. If gas connections have been made and checked, replace fireplace floor assembly. Feed flexible gas supply line into fireplace base area while replac- ing fireplace floor assembly. Make sure the entire flexible gas line is in fireplace base area. IMPORTANT: Do not pick up fire- place floor assembly by burners. This could damage burners. Only handle base by grates. Note: Be careful of all wires and components on underside of floor assembly. 12. Reattach fireplace floor assembly with screws removed in step 3 of Removing Fireplace Screen and Floor Assembly, page 8. Note: Discard the remaining hardware items. After assembly, make sure all wires are completely clear of blower wheel.
Light your gas appliance with the blower off. After about 15 minutes, turn the blower on to deliver heated air at the top louvers. The blower features a variable control which allows you to select the speed you desire. Note: Periodically check the louvers of the firebox and remove any dust, dirt, or other obstructions.
is recessed and if an outlet is not installed in your fireplace, you must install the GA3555 Outlet kit with cover in your fireplace which will supply a convenient 3-prong grounded electrical outlet for your blower. Refer to the installation manual provided with the model GA3555 accessory for instructions on wiring the duplex outlet. Note: A qualified installer must make all electrical connections.
If any of the original wire as supplied with the appliance must be replaced, it must be replaced with 105°C wire or it’s equivalent.
On 110/115 V.A.C.
110/115 V.A.C.
Plastic Bushing Right Floor Support Bracket
Wiring Diagram 101584-05 120 Vac. 60 Hz. . 78 Amps DESA International, Bowling Green, KY
Figure 16 - Installing Plastic Bushing for Power Cord
Figure 17 - Location of Wiring Diagram Decal 3" from Blower

4. Remove the three screws (do not dis- card) and cover plate from center of firebox wrapper rear wall. Discard this cover plate (see Figure 18). 5. Mount the supplied thermostatic switch and cover assembly into firebox wrap- per wall. Do this by feeding terminal ends of wire harness into the hole. Al- low wires to fall to bottom of firebox cavity (see Figure 18). 6. Using three screws from step 7, attach switch and cover assembly to firebox wrapper rear wall. Tighten screws firmly (see Figure 18). 7. Firmly attach red wire from the ther- mostatic switch and cover assembly to either of the terminals on the blower motor (see Figure 18). 8. Firmly attach black wire from speed con- trol cord to blue wire from thermostatic switch and cover assembly (see Figure 18). 9. Firmly attach white wire from speed control cord to remaining terminal on blower motor (see Figure 18). 10. Place control knob provided on plastic control shaft of speed control (see Fig- ure 20).
1. If fireplace screen and floor are still installed, see Removing Fireplace Screen and Floor Assembly, page 8. 2. Using screw provided, attach green ground wire from speed control cord to blower housing.Tighten screw se- curely (see Figure 18). 3. Place the blower against lower rear wall of firebox outer wrapper with the ex- haust port directed upward. Align the holes in top mounting tabs of blower with holes in wall of wrapper (see Fig- ure 19). Using two #8 screws provided, mount blower and tighten screws firmly.
standing unit with an accessory mantel, determine whether the power cord will exit the left side or the right side of the firebox. Install one plastic bushing provided into the 1 1/2" hole in the floor support on the exit side. Install the second bushing provided into the 1 1/2" hole in the outer casing through which the power cord will exit (see Figures 21 and 22, page 13). Route power cord through plastic bushings and plug the power cord into a properly grounded three-prong wall receptacle near the firebox. b. If your fireplace system installation
is recessed and if an outlet is not installed in your fireplace, you must install the GA3555 Outlet kit with cover in your fireplace which will supply a convenient 3-prong grounded electrical outlet for your blower. Refer to the installation manual provided with the model GA3555 accessory for instructions on wiring the duplex outlet. Note: A qualified installer must make all electrical connections.
Thermostatic Switch and Cover Assembly

Speed Control Figure 19 - Mounting Blower to Firebox
Figure 18 - Installing Switch and Cover Assembly, and Speed Control

15. If gas connections have been made and checked, replace fireplace floor assem- bly in fireplace. Feed flexible gas sup- ply line into fireplace base area while replacing fireplace floor assembly. Make sure the entire flexible gas line is in fire- place base area. IMPORTANT: Do not pick up fireplace floor assembly by burners. This could damage burners. Only handle base by grates. Note: Be careful of all wires and components on underside of floor assembly. 16. Reattach fireplace floor assembly with screws removed in step 3 of Removing Fireplace Screen and Floor Assembly, page 8. Note: Discard the remaining hardware items. After assembly, make sure all wires are completely clear of blower wheel. 17. Install logs (see Installing Logs, pages 19 and 20) and fireplace screen (see In- stalling Fireplace Screen, page 20).
If any of the original wire as supplied with the appliance must be replaced, it must be replaced with 105˚C wire or it's equivalent.
After final installation of your fireplace, light your gas appliance with the blower off. After about 15 minutes, turn the blower on to deliver heated air at the top louvers. The blower features a variable control which allows you to select the speed you desire. In the OFF position, the blower will not oper- ate. In the ON position, the blower will start when the thermostat senses a sufficient in- crease in firebox temperature (approximately 10 to 20 minutes depending on heat setting).
Your gas logs and thermostat blower will not turn on and off at the same time. The fireplace may run for several minutes before the blower turns on. After the heater modu- lates to the pilot position, the blower will continue to run. The blower will shut off after the firebox temperature decreases.
It is safe to operate fireplace with blower turned off. However, the blower helps dis- tribute heated air from the fireplace.
Right Floor Support Bracket Plastic Bushing
Figure 21 - Installing Plastic Bushing for Power Cord (Right Side Exit Shown)
Bushing Location for Freestanding Installation Plastic Bushing
If any of the original wire as supplied with the appliance must be replaced, it must be replaced with 105°C wire or it’s equivalent.
Bushing Location for Recessed Installation
Variable Fan Switch Fan Switch
Figure 22 - Installing Bushings (Left Side Exit shown)
110/115 V.A.C.
110/115 V.A.C.
Wiring Diagram 120 Vac. 60 Hz. .90 Amps DESA International, Bowling Green, KY
Figure 23 - Location of Wiring Diagram Decal 3" from Blower

We recommend that you install a sediment trap in supply line as shown in Figure 25. Locate sediment trap where it is within reach for cleaning. Install in piping system between fuel supply and fireplace. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap traps mois- ture and contaminants. This keeps them from going into fireplace gas controls. If sediment trap is not installed or is installed wrong, fireplace may not run properly.
Installation must include an equipment shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from fireplace (see Figure 25).
CSA Design- Certified Equipment Shutoff Valve With 1/8" NPT Tap*
From External Regulator (11" W.C. to 14 " W.C. Pressure
Check your building codes for any special requirements for locating equipment shutoff valve to fireplaces.
Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged fireplace valves.
Pipe Cap Tee Nipple Joint
Figure 25 - Gas Connection
* Purchase the optional CSA design-certi- fied equipment shutoff valve from your dealer. See Accessories, page 34.
* A CSA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Pur- chase the optional CSA design-certified equipment shutoff valve from your dealer. See Accessories, page 34.
The installer must supply an external regu- lator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incom- ing gas pressure, heater regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure 24. Pointing the vent down protects it from freezing rain or sleet.
Figure 24 - External Regulator with Vent Pointing Down

To Fireplace Gas Regulator
Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa) 1. Close equipment shutoff valve (see Figure 27). 2. Pressurize supply piping system by ei- ther using compressed air or opening propane/LP supply tank valve. 3. Check all joints from propane/LP sup- ply to equipment shutoff valve (see Fig- ure 28, page 16). Apply mixture of liq- uid soap and water to gas joints. Bubbles forming show a leak. 4. Correct all leaks at once.
Flexible Gas Line from Fireplace Gas Regulator
Equipment Shutoff Valve Provided by Installer
Figure 26 - Attaching Gas Lines Together
Pressure Testing Fireplace Gas Connections 1. Open equipment shutoff valve (see Fig- ure 27). 2. Open propane/LP supply tank valve. 3. Make sure control knob of fireplace is in the OFF position. 4. Check all joints from equipment shutoff valve to thermostat gas valve (see Fig- ure 28, page 16). Apply mixture of liq- uid soap and water to gas joints. Bubbles forming show a leak. 5. Correct all leaks at once. 6. Light fireplace (see Operating Fire- place, pages 21 and 22). Check all other internal joints for leaks. 7. Turn off fireplace (see To Turn Off Gas to Appliance, page 22).
3. Attach the flexible gas line to gas sup- ply (see Figure 26). Check tightness of flexible gas line attached to gas regu- lator of fireplace (see Figure 26). 4. Check all gas connections for leaks. See Checking Gas Connections. 5. Replace log base assembly back into fireplace. Feed flexible gas line into fire- place base area while replacing log base assembly. Make sure the entire flexible gas line is in fireplace base area. Reat- tach log base assembly to fireplace with screws removed in step 2.
Test Pressures In Excess Of 1/2 PSIG (3.5 kPa) 1. Disconnect appliance with its appliance main gas valve (control valve) and equip- ment shutoff valve from gas supply pip- ing system. Pressures in excess of 1/2 psig will damage fireplace gas regulator. 2. Cap off open end of gas pipe where equipment shutoff valve was connected. 3. Pressurize supply piping system by ei- ther using compressed air or opening propane/LP supply tank valve. 4. Check all joints of gas supply piping system. Apply mixture of liquid soap and water to gas joints. Bubbles form- ing show a leak. 5. Correct all leaks at once. 6. Reconnect fireplace and equipment shutoff valve to gas supply. Check re- connected fittings for leaks.
Open Equipment Shutoff Valve
OFF POSITION
Figure 27 - Equipment Shutoff Valve

5. Route flexible gas line through access hole in hearth base. 6. Center cabinet mantel on hearth base (see Figure 30). Make sure mantel is flush against wall. 7. Break off nailing flanges (see Figure 31) with hammer or pliers. 8. Place cardboard or other protective ma- terial on top of hearth base. Carefully set fireplace on protective material, with back of fireplace inside mantel opening. 9. Attach flexible gas line to fireplace gas regulator. See Connecting Fireplace to Gas Supply, page 15.
Figure 28 - Checking Gas Joints
3. If not already completed, install gas piping to fireplace location. This instal- lation includes an approved flexible gas line (if allowed by local codes) after the equipment shutoff valve. The flex- ible gas line must be the last item in- stalled on the gas piping. See Install- ing Gas Piping to Fireplace Location, page 14. 4. Place hearth base accessory against wall at installation location. Cut an ac- cess hole in hearth top to run flexible gas line to fireplace (see Figure 29). Make sure to locate access hole so cabi- net mantel will cover it when installed. Note: You can secure base to floor us- ing wood screws. Countersink screw heads and putty over.
Conventional installation of fireplace involves installing fireplace along with corner, face, or cabinet mantel with hearth base accessories against a wall in your home. Follow instruc- tions below to install fireplace in this manner.
Note: The instructions below show installa- tion using the cabinet mantel and hearth base accessories (see Accessories, page 34). The hearth base accessory shown is optional for this installation. You can install fire- place and cabinet mantel directly on the floor. The corner mantel accessory cannot be installed with the hearth bases. You must install corner mantel directly on the floor. 1. Assemble cabinet mantel, hearth base, and trim accessories. Assembly instruc- tions are included with each accessory. 2. When installing blower, install a prop- erly grounded, 120 volt three-prong electrical outlet at fireplace location if an outlet is not there. If possible, lo- cate outlet so cabinet mantel will cover it when installed (see Figure 29).
Figure 30 - Installing Cabinet Mantel
Electrical Outlet Hearth Base
Gas Line Access Hole
Figure 31 - Location of Nailing Flanges
Figure 29 - Placing Hearth Base Accessory Against Wall

Built-in installation of this fireplace involves installing fireplace into a framed-in enclosure. This makes the front of fireplace flush with wall. If installing a mantel above the fireplace, you must follow the clearances shown in Figure 36, page 18. Follow the instructions below to install the fireplace in this manner.
10. Route electrical cord(s) through access holes in either side of fireplace with bushing. Plug electrical cord(s) into electrical outlet. 11. Carefully insert fireplace into cabinet mantel. Be careful not to scratch or damage hearth base, cabinet mantel, or any laminate trim on hearth base. Re- move protective material from top of hearth base and from front of fireplace (if any). Note: You can secure fireplace to hearth or floor. Open lower louver. Locate screw holes in bottom of base. Tighten wood screws through these holes and into hearth or floor. 12. Check all gas connections for leaks. See Checking Gas Connections, page 15.
Figure 33 - Rough Opening for Installing in Wall
Height 32 3/8" 33"
Front Width 34 5/16" 35 1/2"
Depth 16 11/16" 17 3/4"
1. Frame in rough opening. Use dimen- sions shown in Figure 33 for the rough opening. If installing in a corner, use dimensions shown in Figure 34 for the rough opening. The height is 33" which is the same as the wall opening above. 2. Install and properly ground GA3555, three-prong 120 volt electrical outlet, in fireplace. Follow instructions in- cluded in kit (see Accessories, page 34). 3. If not already completed, install gas pip- ing to fireplace location. This installa- tion includes an approved flexible gas line (if allowed by local codes) after the equipment shutoff valve. The flexible gas line must be the last item installed on the gas piping. See Installing Gas Piping to Fireplace Location, page 14. 4. Carefully set fireplace in front of rough opening with back of fireplace inside wall opening. 5. Attach flexible gas line to gas supply. See Connecting Fireplace to Gas Sup- ply, page 15. 6. Plug electrical cord(s) into electrical outlet installed in step 2. 7. Carefully insert fireplace into rough opening. 8. Attach fireplace to wall studs using nails or wood screws through holes in nailing flange (see Figure 35). 9. Check all gas connections for leaks. See Checking Gas Connections, page 15. 10. Install brass trim. See Assembling and Attaching Optional Brass Trim, page 18.
39 3/8" 27 7/8"
55 5/8" 35 1/2"
Figure 34 - Rough Opening for Installing in Corner
Nails or Wood Screws
Figure 32 - Inserting Fireplace Into Cabinet Mantel
Figure 35 - Attaching Fireplace to Wall Studs

If placing mantel above built-in fireplace, you must meet minimum clearance between mantel shelf and top of fireplace opening.
Wall board or facing material (above firebox) may be of combustible material, including decorative mantel ornaments or other similar projec- tions off of the facing material.


Noncombustible Material May Project Off this Surface above the Firebox Hood
Supplied Firebox Hood Must Be Used at All Times
Figure 37 - Assembling Brass Trim

Figure 36 - Minimum Mantel Clearances for Built-In Installation
Hanging Notches on Trim
INote: The instructions below show assem- bling and attaching brass trim to fireplace. 1. Remove packaging from three pieces of brass trim. 2. Locate four brass screws, two adjust- ing plates with set screws, and two shims in the hardware packet. 3. Align shim under adjusting plate as shown in Figure 37. 4. Slide one end of adjusting plate/shim in slot on mitered edge of top brass trim (see Figure 37). 5. Slide other end of adjusting plate/shim in slot on mitered edge of side brass trim (see Figure 37).
Figure 38 - Attaching Brass Trim to Fireplace
Install hood to top of firebox as shown in Figure 39. Use 3 Phillips screws provided.
Figure 39 - Installing Hood to Firebox
Set Screws · Trim Hanging Screws · 18 107570

2. Place the base of the middle log (#2) in the U-shaped slots of the grate base in front of the back log. The cutout on the right of the middle log should fit over the burner (see Figure 41). Make sure the front of the middle log is resting on the tabs of the grate base and the cutout area is centered over the burner “U” bend. 3. Locate the recesses on the back of the front log (#3). Fit these recesses between the posts of the grate base (see Figure 42). 4. Locate the notches in the bottom of the crossover log (#4). Place the crossover log on top of the middle log and front log. Make sure the notches of the crossover log lines up with rectangular knobs on top of the middle and front logs (see Figure 43).
Figure 43 - Installing Crossover Log (#4)
Each log is marked with a number. These numbers will help you identify the log when installing. It is very important to install these logs exactly as instructed. Do not modify logs. Only use logs supplied with heater. 1. Locate pegs on the bottom of back log (#1). Slide these pegs into the holes in the grate base behind the burner (see Figure 40).
Hole in Grate Base
Figure 41 - Installing Middle Log (#2)
Each log is marked with a number. These numbers will help you identify the log when installing. It is very important to install these logs exactly as instructed. Do not modify logs. Only use logs supplied with heater.
Figure 40 - Installing Back Log (#1)
Figure 42 - Installing Front Log (#3)

1. Place the base of the middle log (#1) in the U-shaped slots of the grate base. The cutout on the right of the middle log should fit over the burner (see Fig- ure 44). Make sure the front of the middle log is resting on the tabs of the grate base and the cutout area is cen- tered over the burner “U” bend. 2. Locate pegs on the bottom of back log (#2). Slide these pegs into the holes in the grate base behind the burner (see Figure 45).
Install fireplace screen by slipping notches of fireplace screen over screws on front of fireplace (see Figure 48).


Figure 48 - Installing Fireplace Screen
INSTALLING BATTERY INTO REMOTE 1. Locate slot at bottom of remote con- trol (see Figure 49). Firmly insert tool such as a small screwdriver, butter knife, or dime into the slot and lift up to remove cover. 2. Insert supplied battery into remote control. Positive and negative are marked inside remote control casing. Note: Remote will not function if bat- tery is not installed correctly. 3. Slide tab on cover into remote housing and snap cover back into place.

Figure 45 - Installing Back Log (#2)
Figure 49 - Installing Battery
Slot · Negative · 20 107570

FOR YOUR SAFETY
LIGHTING
Figure 50 - Pilot
Manual Ignition Bypass Switch (Up is for Remote Control)
HI LO
ON OFF
LED
Figure 51 - Control Locations
B. Using Hand-Held Wireless Remote Control 1. Set manual ignition bypass switch on control panel to OFF position (auto- matic ignition position). 2. Wait five (5) minutes to clear out any gas. Smell for gas around heater and near floor. If you smell gas, STOP! Follow “B” in the safety information on warnings plate. If you don’t smell gas, go to the next step. 3. Point remote control toward the lower front of fireplace and push both but- tons at the same time. Hold for 6 sec- onds. The gas valve will open and elec- tronic ignition will begin sparking to light the pilot. Note: You will be able to hear a clicking sound during this process. LED on wall switch will light. Note: You may be running this heater for the first time after connecting to gas supply or at the start of your heat- ing season. If so, the ON button may need to be pressed again. This will allow air to bleed from gas system. If several attempts to light pilot fail, con- tact a qualified service person or gas supplier for repairs. Until repairs are made, light and operate manually (see Manual Lighting Instructions for Elec- trical Power Outage, page 20).
A. Using Supplied Wall Switch 1. Set manual ignition bypass switch on the control panel to the OFF position (automatic ignition position). 2. Press ON/OFF button. Hold for 6 seconds. Gas valve will open and elec- tronic ignition will begin sparking to light pilot. LED will light. Note: You may be running this heater for the first time after connecting to gas supply or at the start of your heat- ing season. If so, the ON/OFF button may need to be pressed again. This will allow air to bleed from gas system. If several attempts to light pilot fail, con- tact a qualified service person or gas supplier for repairs. Until repairs are made, light and operate manually (see Manual Lighting Instructions for Elec- tric Power Outage, page 22). 3. When pilot flame is lit, the thermo- couple is heated by the flame. When thermocouple becomes hot (5 to 15 seconds), main burner will automati- cally light on high flame. 4. To lower flame, push HI/LO button on wall switch once. Note: This fireplace does not have a pilot-only mode.

Because this fireplace has an electronic ignition system, in the event there is a loss of power, it will be necessary to manually light the pilot with the piezo ignitor. After the pilot is lit, the main burner will light automatically. 1. Follow steps 1 through 3 under Nor- mal Lighting Instructions, page 21. 2. Set manual ignition bypass switch on control panel to ON position (manual ignition position). See Figure 52. 3. The pilot is attached to the rear of the front burner. You will be able to see the pilot and spark electrode without removing the screen or logs. 4. Place the magnetic manual override handle, provided with this unit, on the end of the gas valve stem (see Fig- ure 51). 5. Turn the override handle fully coun- terclockwise to the PILOT po- sition. The handle will not stop but will begin to slip when you have fully turned to the PILOT position. 6. While holding the valve handle in the PILOT position, press and release piezo ignitor button (see Figure 52). This will light the pilot. If needed, keep pressing ignitor button until pi- lot lights. 7. When pilot flame is lit, hold manual override handle until thermocouple heats (approximately 5 to 15 sec- onds). If pilot goes out, repeat pro- cess. If several attempts to light the pilot fail, contact a qualified service person or gas supplier for repairs.
TO APPLIANCE
Shutting Off Heater When Manually Lit
Set manual ignition bypass switch on con- trol panel to OFF (automatic ignition position). This will cause the controls to shut down the fireplace.
OPTIONAL BLOWER
OPERATION
TO APPLIANCE
Shutting Off Heater - Wall Switch
Locate the blower switch by opening lower louver on fireplace. Blower switch is lo- cated at lower right inside louver door.
Push ON/OFF button on wall switch once.
The GA3650TA Series thermostat-con- trolled blower has a variable speed con- trol with an ON/OFF switch. The blower will start when the thermostat senses a sufficient increase in firebox temperature. The GA3750 Series variable speed blower also has an ON/OFF switch built into the variable speed control.
Point remote control toward lower front of fireplace and push both buttons at the same time.
INSTRUCTIONS FOR ELECTRICAL
Note for GA3650TA Series Only: If you are using GA3650TA blower, your fireplace and blower will not turn on and off at the same time. The fireplace may run for several minutes before the blower turns on. After the heater modulates to the pilot position, the blower will con- tinue to run. The blower will shut off after the firebox temperature decreases.
Manual Ignition Bypass Switch (Down is ON)
Follow installation instructions included with the blower accessory.
HI LO
ON OFF
Magnetic Manual Override Handle ON/OFF Button
Figure 52 - Control Locations

CLEANING AND MAINTENANCE
Clean the pilot assembly also. A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly. There is a small pilot air inlet hole about two inches from where the pilot flame comes out of the pilot assembly (see Figure 56). With the unit off, lightly blow air through the air inlet hole. You may blow through a drinking straw if compressed air is not available.
Check pilot flame pattern and burner flame patterns often.
Figure 53 shows a correct pilot flame pat- tern. Figure 54 shows an incorrect pilot flame pattern. The incorrect pilot flame is not properly heating the thermocouple. When the thermocouple cools, the heater will shut down.
CLEANING BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLE The primary air inlet holes allow the proper amount of air to mix with the gas. This pro- vides a clean burning flame. Keep these holes clear of dust, dirt, lint, and pet hair. Clean these air inlet holes prior to each heating season. Blocked air holes will create soot. We recom- mend that you clean the unit every every three months during operation and have heater in- spected yearly by a qualified service person.
Figure 55 - Injector Holder On Outlet Burner Tube
Pilot Air Inlet Hole
Figure 53 - Correct Pilot Flame Pattern
We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt. To clean these parts we recommend using compressed air no greater than 30 PSI. Your local computer store, hardware store, or home center may carry compressed air in a can. You can use a vacuum cleaner in the blow position. If using compressed air in a can, please follow the directions on the can. If you don't follow directions on the can, you could damage the pilot assembly. 1. Shut off the unit, including the pilot. Allow the unit to cool for at least thirty minutes. 2. Inspect burner, pilot, and primary air inlet holes on injector holder for dust and dirt (see Figure 55). 3. Blow air through the ports/slots and holes in the burner. 4. Check the injector holder located at the end of the burner tube again. Remove any large particles of dust, dirt, lint, or pet hair with a soft cloth or vacuum cleaner nozzle. 5. Blow air into the primary air holes on the injector holder.
Figure 56 - Pilot Inlet Air Hole
Figure 54 - Incorrect Pilot Flame Pattern
Periodically inspect all burner flame holes with the heater running. All slotted burner flame holes should be open with yellow flame present. All round burner flame holes should be open with a small blue flame present. Some burner flame holes may be- come blocked by debris or rust, with no flame present. If so, turn off heater and let cool. Either remove blockage or replace burner. Blocked burner flame holes will create soot.
Periodically inspect all burner flame holes with the heater running. All slotted burner flame holes should be open with yellow flame present. All round burner flame holes should be open with a small blue flame present. Some burner flame holes may be- come blocked by debris or rust, with no flame present. If so, turn off heater and let cool. Either remove blockage or replace burner. Blocked burner flame holes will create soot.

TROUBLESHOOTING WARNING: Turn off heater and let cool before servicing. Only a qualified service person should service and repair heater.
POSSIBLE CAUSE
REMEDY
When buttons on remote control are pressed, there is no response from fireplace
When wall switch button is pressed, there is no response from fireplace
Burner does not light after ODS/pilot is lit
Burner backfiring during combustion
Slight smoke or odor during initial operation
Moisture/condensation noticed on windows
Delayed ignition burner · 24 107570

POSSIBLE CAUSE
REMEDY
Heater produces a whistling noise when burner is lit
When ignitor button is pressed, there is no spark at ODS/pilot (manual ignition mode)
When ignitor button is pressed, there is spark at ODS/pilot but no ignition (manual ignition mode)
ODS/pilot lights but flame goes out when control knob is released (manual ignition mode)
B) Clean ODS/pilot (see Cleaning and Maintenance, page 23) or replace ODS/ pilot assembly
www.desatech.com Continued
25 107570

POSSIBLE CAUSE
REMEDY
Fireplace produces a clicking/ticking noise just after burners are lit or shut off
Fireplace produces unwanted odors
Fireplace shuts off in use (ODS operates)
Gas odor even when wall switch and remote control buttons and switches are in OFF position
Gas odor during combustion
Dark residue on logs or inside of fireplace Note: After removng all causes of residue deposits, completely clean fireplace and appli- ances of all residue before reusing appliance.
White powder residue forming within burner box or on adjacent walls or furniture
26 107570

27 107570

REPLACEMENT PARTS
Btu (Variable) 20,000/33,000 Type Gas Propane/LP Gas Only Ignition Electronic (Automatic)/Piezo (Manual) Pressure Manifold 3.5" W.C. Inlet Gas Pressure (in. of water)
Maximum 10.5" Minimum* 5" Shipping Weight 122 lbs. * For input adjustment
Contact authorized dealers of this product. If they can’t supply original replacement part(s), call DESA International’s Techni- cal Service Department at 1-800-DESA LOG (1-800-337-2564).
SERVICE HINTS
You may have further questions about in- stallation, operation, or troubleshooting.
If so, contact DESA International’s Techni- cal Service Department at 1-800-DESA LOG (1-800-337-2564).
Usually, we will ask you to return the defec- tive part to the factory.
You can also visit DESA International’s technical service web site at www.desatech.com
You may feel your gas pressure is too low or gas quality is bad. If so, contact your local propane/LP gas supplier.
Contact authorized dealers of this product (see page 29). If they can’t supply original replacement part(s), call DESA International’s Parts Department at 1-800-972-7879 for re- ferral information.
28 107570

These Parts Dealers are privately owned businesses. They have agreed to support our customer’s needs by providing original replacement parts and accessories.
Baltimore Electric 1348 Dixwell Avenue Hamden, CT 06514-0322 1-800-397-7553 203-248-7553 Parts Department
Washer Equipment Co. 1715 Main Street Kansas City, MO 64108-2195 KS, MO, AR 816-842-3911 www.washerparts.com
LA Porte’s Parts & Service 2444 N. 5th Street Hartsville, SC 29550-7704 803-332-0191 Parts Department
Cans Unlimited, Inc. P.O. Box 645 Taylor, SC 29687-0013 All States 803-879-3009 1-800-845-5301 cuisales@aol.com
Portable Heater Parts 342 N. County Rd. 400 East Valparaiso, IN 46383-9704 All States 219-462-7441 1-800-362-6951 sales@portableheaterparts.com techservice@portableheaterparts.com
East Coast Energy Products 707 Broadway W. Long Branch, NJ 07764-1542 732-870-8809 1-800-755-8809 www.njplaza.com/ecep
Dayton Hardware P.O. Box 275 North Dayton Station Dayton, OH 45404-0275 All States 937-258-3721 OH 1-800-762-3426
FBD 1349 Adams Street Bowling Green, KY 42103-3414 270-846-1199 1-800-654-8534 Fax: 1-800-846-0090 franktalk@aol.com
Halco Enterprises 208 Carter Drive, Unit 21 West Chester, PA 19382-4500 610-430-7717 1-800-368-0803 www.halcoenterprises.com
Master Parts Dist. 1251 Mound Ave NW Grand Rapids, MI 49504-2672 616-791-0505 1-800-446-1446 Fax: 616-791-8270 www.nbmc.com
29 107570


30 107570

This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 28 of this manual.
KEY PART NUMBER PART NUMBER NO. EFP33PR CGEFP33PR DESCRIPTION QTY.
1 104937-01 103009-01 Middle Log (#1) 1 2 104938-01 103008-01 Back Log (#2) 1 3 104936-01 103010-01 Front Log (#3) 1 4 104939-01 103011-01 Crossover Log (#4) 1 5 104286-02 104286-02 ODS Pilot 1 6 098249-01 098249-01 ODS Nut 2 7 099387-05 099387-05 Pilot Tube 1 8 101973-02 101973-02 Inlet Tube 1 9 107572-01 107572-01 Burner Outlet Tube 1 10 102843-01 102843-01 Burner Clip 1 11 099056-19 099056-19 Burner Orifice Injector 1 12 102772-01 102772-01 Burner 1 13 M10908-2 M10908-2 Screw, Self-Tapping 2 14 104236-01CK 104236-01CK Painted Base Assy 1 15 104238-03CK 104238-03CK Firebox Bottom 1 16 107573-01 107573-01 Valve Bracket 1 17 107559-02 107559-02 Gas Control Valve 1 18 102445-01 102445-01 Piezo Ignitor 1 19 102334-01 102334-01 Palnut Fastener 1 20 107562-01 107562-01 Switch and Wire Assembly 1 21 107685-01 107685-01 Bracket, Switch and Piezo 1 22 101628-03 101628-03 Flexible Connector 1 23 098544-01 098544-01 Wire Support Clip 1 24 099415-13 099415-13 Pressure Regulator 1 25 097809-03 097809-03 Fitting 3/8" Flare to 1/2" NPT 1 26 107687-01 107687-01 Electrode Bracket 1 27 103904-02 103904-02 Electrode 1 28 100694-01 100694-01 Screw, #6 x 1 1/4" PH 2 29 107560-01 107560-01 Magnetic Manual Override Handle 1 30 107563-01 107563-01 Wall Switch and Cord 1 31 107558-01 107558-01 Wall Switch Decorative Plate 1 32 102349-02 102349-02 Support, PCB 4 33 107561-01 107561-01 Wall Plate Decal 1 34 107564-01 107564-01 Remote Control 1 35 107565-01 107565-01 Receiver Assembly 1 36 107565-02 107565-02 Sensor Assembly 1 37 107566-01 107566-01 Module, Control Board 1 38 098271-08 098271-08 Ignitor Cable 1 39 107568-01 107568-01 Main Power Cable 1 40 098219-37 098219-37 Power Cord 1 41 101629-01 101629-01 1.5" Bushing 2 42 098303-02 098303-02 Screw, #6 2 43 107743-01 107743-01 Thermocouple Wire 1 44 107847-01 107847-01 Screw, #6019 x 1/4" 2
19724000 19724000 Cable Tie 4 107073-03 107073-03 Information Video 1 901056-01 901056-01 Fitting, 3/8" NPT 1 107736-01 107736-01 Wall Plate Assembly Kit (Contains Items 31, 33, 44) 107737-01 107737-01 Wall Switch Assembly Kit (Contains Items 28, 30, 31, 33, 44)
31 107570


32 107570

This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 28 of this manual.
KEY NO. PART NUMBER DESCRIPTION QTY.
1 101357-03 Top Outer Casing 1 2 103207-01 Outer Casing 1 3 102758-02CK Right Front Side 1 4 102759-02CK Left Front Side 1 5 098304-01 Phillips Pan Head Screw, #10 9 6 104239-01CK Top Front Louver 1 7 101712-03 Firebox Hood 1 8 101348-01 Firebox Support 2 9 099230-02 Shoulder Screw 4 10 101872-03 Firebox Top 1 11 101346-01CK Outer Base 1 12 101838-03 Firebox Wrapper 1 13 101514-01CK Cover 1 14 M11084-26 Hex Screw, #10 45 15 104242-01CK Bottom Louvered Door 1 16 101727-02 Screen Assembly 1
101386-02 Louvered Door Hinge 2 101784-01 Magnet Catch 2 102307-01 Strike Plate 2
33 107570


Purchase these fireplace accessories from your local dealer or Parts Dealers list on page 29. If they can not supply these acces- sories, call DESA International’s Sales De- partment at 1-800-458-2472 for referral in- formation. You can also write to the address listed on the back page of this manual.
GMC37U Series - Unfinished Birch Veneer, Ready to Stain or Paint.
Space saving corner mantels feature mold- ings, fluting and medallion.
GMC12U Series - Unfinished Hardwood Veneer, Ready to Stain or Paint.
CABINET MANTEL AND BASE ACCESSORY WITH FIREPLACE PERIMETER TRIM (Not Available at All Locations)
GMC13F Series - Medium Stained Oak Veneer
For all models. Equipment shutoff valve with 1/8" NPT tap. Fits 1/2" NPT pipe.
Mantel features moldings, fluted sides, and medallion.
GMC10CF Series - Stained Oak Veneer
HEARTH BASE (for Use with Cabinet Mantel)
Mantel and base feature moldings, fluted sides, and medallion.
GC3333F Series - Walnut Finished Hardwood Veneer
Manual variable control and automatic ther- mostat variable control. A blower will in- crease air flow to maximize heat distribution.
BRASS TRIM ACCESSORY GA7090 (Not Shown)
CLEANING KIT - CCK (Not Shown)
The hearth base creates a handsome riser for the fireplace .
Optional with built-in installation. Provides a finished appearance covering rough and/or unfinished mantel or wall opening, edges, etc.
Your vent-free gas appliance requires regu- lar cleaning and maintenance to prevent performance problems. This kit gives you the tools and instructions to make it easy to clean all critical areas of your appliance.
Use for built-in installations when hard wir- ing your fireplace.
34 107570

3/8" Diameter 2 Holes 1/8" Diameter 2 Holes
4 3/4" 4 3/4"
3 3/4"
3 3/4"
Template 1 - Relocating Wall Switch to Hollow Room Wall Template 2 - Relocating Wall Switch to Side Wall of Mantel

36 107570


Serial No.
Always specify model and serial numbers when communicating with the factory.
We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied.
DESA International warrants this product to be free from defects in materials and components for two (2) years from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions. To make a claim under this warranty the Bill of Sale or cancelled check must be presented.
This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required to restore this heater to proper operating condition and an allowance for labor when provided by a DESA Authorized Service Center. Warranty part(s) MUST be obtained through authorized dealers of this product and/or DESA International who will provide original factory replacement parts. Failure to use original factory replacement parts voids this warranty. The heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit.
This warranty does not apply to parts that are not in original condition because of normal wear and tear, or parts that fail or become damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation. Travel, diagnostic cost, labor, transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner.
TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO TWO (2) YEARS ON ALL COMPONENTS FROM THE DATE OF FIRST PURCHASE; AND DESA INTERNATIONAL’S LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND DESA INTERNATIONAL SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES.
Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or consequential damages, so the above limitation on implied warranties, or exclusion or limitation on damages may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.
For information about this warranty write:
2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004 www.desatech.com