EN
JBC logo
Official user manual

JBC Robot Control Unit

19 pages·420 KB·Controller·PDF·ENDEFRITNLJA
JBC Robot Control Unit
Table of Contents 25 sections Robot Control · User Manual · CONTENT · 1. Introduction · … ShowHide
Page 1 of the JBC Robot Control Unit user manual — Robot Control
Page 1 · click to enlarge
Page 1
JBC Robot Control Unit — Robot Control diagram (page 1)
Fig. 1 · Robot Control

Robot Control

User Manual

0021919/0721

Page 2 of the JBC Robot Control Unit user manual — Robot Control
Page 2 · click to enlarge
Page 2
JBC Robot Control Unit — Robot Control diagram (page 2)
Fig. 2 · Robot Control
Page 3 of the JBC Robot Control Unit user manual — 11.3 COUNTER PANEL - SFR CONNECTED ............................................................................................................... 16
Page 3 · click to enlarge
Page 3

CONTENT

1. INTRODUCTION 4

2. PROGRAM DESCRIPTION ..................................................................................................................................... 4

3. SKR CONNECTION ................................................................................................................................................ 5

4. PROGRAM INSTALLATION ................................................................................................................................... 6

5. DRIVER INSTALLATION ........................................................................................................................................ 6

6. MAIN SCREEN ...................................................................................................................................................... 7

7. CONNECTING ....................................................................................................................................................... 8

8. UCR OPTIONS ...................................................................................................................................................... 9

9. PANELS ................................................................................................................................................................ 9

10. USER MODE – UCR CONNECTED .......................................................................................................................... 9

10.1 GENERAL PANEL - UCR CONNECTED ............................................................................................................... 10

10.2 DEVICE SETTINGS PANEL - UCR CONNECTED 11

10.3 TOOL SETTINGS PANEL - UCR CONNECTED 12

10.4 COUNTER PANEL - UCR CONNECTED 13

11. USER MODE – SFR CONNECTED .......................................................................................................................... 13

11.1 GENERAL PANEL - SFR CONNECTED ................................................................................................................ 14

11.2 DEVICE SETTINGS PANEL - SFR CONNECTED 15

11.3 COUNTER PANEL - SFR CONNECTED 16

12. DEVELOPER MODE PANEL .................................................................................................................................. 17

12.1 SNIFFER MODE PANEL .................................................................................................................................... 19

Page 4 of the JBC Robot Control Unit user manual — 2. Program Description
Page 4 · click to enlarge
Page 4

1. Introduction

The Robot Control is used to support programmers during the start-up phase, integrating JBC devices as UCR and SFR into automated soldering processes.

The use of the SKR is not required after the JBC Device is integrated. It is only required at certain times when you wish to intercept communication frames between the JBC Device and the Robot (PLC).

Robot Control, together with the Starter Kit for Automation (SKR), facilitates integration between the Robot's Processor (PLC or Industrial PC) and one of the following JBC Devices:

  • UCR Control Unit for Automation (serial communication RS-232 * )
  • SFR Solder Feeder for Automation (serial communication RS-232 * )
  • CLMR Tip Cleaner for Automation (on/off switch input * )

*see corresponding Communication Protocol at www.jbctools.com/jbcsoftware.html

2. Program Description

The SKR with this Program allows two connection modes, the "Control Mode" and the "Sniffer Mode".

Control Mode With this mode you can command/get answered communication frames, which are sent between the PC and the JBC Device.

Sniffer Mode This mode is used to intercept the communication frames sent between the Robot/PLC and the JBC Device. These communication frames are displayed on the Sniffer Mode Panel. Sniffer Mode also facilitates the debugging of the Robot Control Software by frame decoding and visualization in real time. See page 20 for more information.

Page 5 of the JBC Robot Control Unit user manual — Sniffer Mode
Page 5 · click to enlarge
Page 5

3. SKR Connection

For detailed information about cable connections between the SKR, JBC Devices, PC, and the Robot see the SKR User Manual Ref. 0021922 at https://www.jbctools.com/

Control Mode

JBC Robot Control Unit — Control Mode diagram (page 5)
Fig. 3 · Control Mode

Sniffer Mode

JBC Robot Control Unit — Sniffer Mode diagram (page 5)
Fig. 4 · Sniffer Mode
Page 6 of the JBC Robot Control Unit user manual — 5. Driver Installation
Page 6 · click to enlarge
Page 6

4. Program Installation

The SKR contains two CP2102 (Silicon Labs) integrated circuit-based serial channel emulators that serve to convert a USB connection into a classic asynchronous serial channel.

Step-by step installation of Robot Control:

1. Download the JBC Web Program at https://www.jbctools.com/jbcsoftware.html An “.exe” file will download to your PC. 2. Run the “.exe” file to install the program on your PC. 3. If the corresponding drivers are missing, you must accept their automatic installation during the ".exe" file installation process. (CP2102 driver from Silicon Labs). 4. Now complete the “.exe” program's installation. 5. Open the program by clicking on the program icon installed on your PC. The JBC Device must be connected to your PC.

5. Driver Installation

When the SKR is connected to your PC (via USB) and the Robot Control is installed, your PC will begin the driver installation process.

To work directly with the Robot-connected SKR without downloading the JBC program, the drivers can be downloaded directly from the Silicon Labs website by following this link: https://www.silabs.com/products/development-tools/software/usb-to-uart-bridge-vcp-drivers

Page 7 of the JBC Robot Control Unit user manual — 6. Main screen
Page 7 · click to enlarge
Page 7

6. Main screen

When you open the Robot Control you will see the following main screen:

JBC Robot Control Unit — 6. Main screen diagram (page 7)
Fig. 5 · 6. Main screen

Developer (a): It opens the Developer Panel (see page 18). You can access the Developer Panel before connecting any JBC Device.

Help (b): By clicking the “Help” button (a), the “Programmers Guide for UCR and SFR” will open in .pdf format. Connect (c): By clicking on the “Connect” button, the button's symbol will change to green and the word “Disconnect” will be shown.

Click on this same button to disconnect. The button's symbol will change to red and the word "Connect" will be shown.

Options (d): Click this icon to open/close the options display.

Serial Port (e): Select the port where the JBC Device is connected.

With Addresses (f): To connect with addresses, tick the box. To connect without addresses, the box must be unticked.

h

Page 8 of the JBC Robot Control Unit user manual — 7. Connecting
Page 8 · click to enlarge
Page 8

Local Address (g): Select the address of the local PC.

Station Address (h): Select the address of the JBC Device.

  • UCR default address “1”
  • SFR default address “10”
  • Local PC default address “0”

JBC Logo (i): By clicking on the JBC logo at the bottom of the display, you will be redirected to the JBC website https://www.jbctools.com/

7. Connecting

In order to connect the UCR or the SFR, you need to make the following steps:

1. Choose the Serial Port in which the device is connected. 2. Select the Station Address according to your device: a. UCR default address “1” b. SFR default address “10”
JBC Robot Control Unit — 7. Connecting diagram (page 8)
Fig. 6 · 7. Connecting
3. Click on “Connect” button in the top.
Page 9 of the JBC Robot Control Unit user manual — 10. User mode – UCR connected
Page 9 · click to enlarge
Page 9

8. UCR Options

Once the JBC Device is connected to a UCR, the Options panel shows the following additional options:

JBC Robot Control Unit — 8. UCR Options diagram (page 9)
Fig. 7 · 8. UCR Options

Unit Temp.: You can select °C or °F for the temperatures selected and shown on-screen.

Select Temp. Chart: Select the min/max temperature for the range of the graphic that will appear to the left.

Save Ranges: To save the range of the graphic.

9. Panels

Once connected, you can select either "User Mode" or "Developer Mode" from the General Panel. The User Mode screen will vary depending on the JBC Device connected.

JBC Robot Control Unit — 9. Panels diagram (page 9)
Fig. 8 · 9. Panels
JBC Robot Control Unit — 9. Panels diagram (page 9)
Fig. 9 · 9. Panels

10. User mode – UCR connected

General Panel JBC Device Settings Panel JBC Tool Settings Panel Counters Panel
JBC Robot Control Unit — 10. User mode – UCR connected diagram (page 9)
Fig. 10 · 10. User mode – UCR connected
Page 10 of the JBC Robot Control Unit user manual — 10.1 General Panel - UCR Connected
Page 10 · click to enlarge
Page 10

10.1 General Panel - UCR Connected

Select the tab to access the General Settings Panel (a).

JBC Robot Control Unit — 10.1 General Panel - UCR Connected diagram (page 10)
Fig. 11 · 10.1 General Panel - UCR Connected

Actual Temperature (b): It indicates the current temperature of the tip.

Selected Temperature (c): It indicates the chosen temperature.

Temperature Adjustment (d): There are 2 buttons for +5 and -5 to adjust the Selected Temperature.

Graphic Chart (e): The graphic shows the temperature (red) and the power (blue). The graphic's range can be changed through the "Select. Temp. Chart” values to the bottom right.

Power Indicator (f): The power's scale indicates the percentage of the power delivered compared to the maximum power of the JBC Device.

Status (g)You can change between following status:
  • Work: The tip will heat up to the Selected Work Temperature.
  • Sleep: The temperature falls to the preset Sleep Temperature. If a Delay Time is defined, the tip begins to drop to room temperature after the time has passed.
  • Extract: The power is cut off and the tool cools down to room temperature. Use this Status to extract the tip.
Page 11 of the JBC Robot Control Unit user manual — 10.2 Device Settings Panel - UCR Connected
Page 11 · click to enlarge
Page 11

10.2 Device Settings Panel - UCR Connected

Select the tab to access the Device Settings Panel (a).

JBC Robot Control Unit — 10.2 Device Settings Panel - UCR Connected diagram (page 11)
Fig. 12 · 10.2 Device Settings Panel - UCR Connected

Max./Min. Temperature (b): You can change the Max./Min. Temperature of the tip. The Selected Temp. must be between these 2 values.

Reset Device Settings (c): Click the symbol and the values return to their default/factory values. You must reboot the station to see the reset values.

Save Selected Temperature to E2PROM (d): The “Save Selected Temperature to E2PROM” function is used to save the modified selected temperature value. The check box must first be ticked to activate this function.

Page 12 of the JBC Robot Control Unit user manual — 10.3 Tool Settings Panel - UCR Connected
Page 12 · click to enlarge
Page 12

10.3 Tool Settings Panel - UCR Connected

Select the Tool Settings tab (a) to configure the settings of the JBC Device and its tools.

JBC Robot Control Unit — 10.3 Tool Settings Panel - UCR Connected diagram (page 12)
Fig. 13 · 10.3 Tool Settings Panel - UCR Connected

Temp. Alarm (b): Define an upper/lower temperature to show a warning.

Adjust Temperature (c): Depending on the cartridge used, you can establish a temperature offset.

Sleep Temp. (d): Temperature during the Sleep phase.

Sleep Delay (e): Time before moving from Work to Sleep.

Hibernation Delay (f): Time before moving from “Sleep” to “Hibernation”.

Page 13 of the JBC Robot Control Unit user manual — 11. User mode – SFR connected
Page 13 · click to enlarge
Page 13

10.4 Counter Panel - UCR Connected

To see hours/work cycles, select the Counters tab (a).

JBC Robot Control Unit — 10.4 Counter Panel - UCR Connected diagram (page 13)
Fig. 14 · 10.4 Counter Panel - UCR Connected

Counters (b): The JBC Device counters show total hours.

Reload counters (c): All values are in read only mode. Values are not automatically updated, so you must “Reload” the Counters by clicking the symbol to see the current values.

11. User mode – SFR connected

JBC Robot Control Unit — 11. User mode – SFR connected diagram (page 13)
Fig. 15 · 11. User mode – SFR connected

JBC Device Settings Panel

General Panel · Counters Panel

Page 14 of the JBC Robot Control Unit user manual — 11.1 General Panel - SFR Connected
Page 14 · click to enlarge
Page 14

11.1 General Panel - SFR Connected

Select the tab to access the General Settings Panel (a).

JBC Robot Control Unit — 11.1 General Panel - SFR Connected diagram (page 14)
Fig. 16 · 11.1 General Panel - SFR Connected

Continuous / Discontinuous (b): Continuous or Discontinuous Mode can be selected.

Speed (c)Always entered as mm/s
Length (d)Always entered as mm (only applicable in discontinuous mode)

Wire Feeding / Stop Feeding (e): Action buttons to start and stop wire feeding.

Start Loading / Stop Loading (f): Action buttons to start and stop wire loading if solder wire is to be fed into the Solder Feeder's Drag Mechanism.

Clear Error (g): Action button to clear the error message.

Error information (h): Information on the error's status, if there is one.

h

Page 15 of the JBC Robot Control Unit user manual — 11.2 Device Settings Panel - SFR Connected
Page 15 · click to enlarge
Page 15

11.2 Device Settings Panel - SFR Connected

Select the tab to access the Device Settings Panel (a).

JBC Robot Control Unit — 11.2 Device Settings Panel - SFR Connected diagram (page 15)
Fig. 17 · 11.2 Device Settings Panel - SFR Connected

Mode (b): Continuous or Discontinuous Mode can be selected.

Speed (c): Set the wire thickness.

Speed (d): Always entered as mm/s.

Length (e): Always entered as mm, and is only applicable in Discontinuous Mode.

Reset Device Settings (f): Click the symbol and the values return to their default/factory values.

Save Settings (g): The modified values are saved after clicking the “Save Settings To Non Volatile Memory” button (E2PROM), otherwise they are not saved when the SFR is restarted.

Page 16 of the JBC Robot Control Unit user manual — 11.3 Counter Panel - SFR Connected
Page 16 · click to enlarge
Page 16

11.3 Counter Panel - SFR Connected

Select the tab to access the Counter Display Panel (a).

JBC Robot Control Unit — 11.3 Counter Panel - SFR Connected diagram (page 16)
Fig. 18 · 11.3 Counter Panel - SFR Connected

The values (b) shown are the total and partial hours of JBC Device counters.

Reload counters (c): Values are not automatically updated, so you must “Reload” the Counters by clicking the symbol to see the current values.

Reset Partial Counters (d): Action button to reset the partial values column to “0”.

Page 17 of the JBC Robot Control Unit user manual — 12. Developer Mode Panel
Page 17 · click to enlarge
Page 17

12. Developer Mode Panel

Used to send frame commands through the program, in order to communicate with the JBC Devices (UCR or SFR). To access the Developer Mode Panel, click the corresponding button (a).

JBC Robot Control Unit — 12. Developer Mode Panel diagram (page 17)
Fig. 19 · 12. Developer Mode Panel

There is a “Commands” space (b) on the left, and another space on the right to view frame communications (c).

Commands (b): Compatible commands will be shown according to the JBC Device connected. Depending on the command selected, the "Read" or "Write" buttons will be shown on the bottom left after clicking on the command.

Read: is to receive (get answered) information/values from the JBC Device.

Write: is to send (command) commands/values to the JBC Device.

When selecting Read/Write, the frame auto-fills using values previously entered in the User Mode Panels, and the frame is shown automatically in the space to the right.

Command/Value (c): Select a Command from the list (b) and send a Value according to the Command.

Communications panel (d): Shows the send (command) and response (get answered) communication frames. The frames are shown in hexadecimal values.

Page 18 of the JBC Robot Control Unit user manual — 12. Developer Mode Panel
Page 18 · click to enlarge
Page 18

Clear Log (e): Action button that clears the screen of received and sent frames.

Discover connected Devices (f): Click to open a new window where you can select between 2 tabs: “Search” and “Log”.

“Search” tab: Click on the “Start Search” button to start searching for Connected Devices. All devices found will be shown once the search is complete. “Log” tab: When executing a search, the search data is shown. The “Clear Log” button clears the display.

JBC Robot Control Unit — 12. Developer Mode Panel diagram (page 18)
Fig. 20 · 12. Developer Mode Panel
JBC Robot Control Unit — 12. Developer Mode Panel diagram (page 18)
Fig. 21 · 12. Developer Mode Panel

“Search” tab “Log” tab

Page 19 of the JBC Robot Control Unit user manual — 12.1 Sniffer Mode Panel
Page 19 · click to enlarge
Page 19

12.1 Sniffer Mode Panel

Sniffer Mode is accessed through the “Sniffer” button. This mode is used to detect sent commands and view JBC Device traffic, if you are using a PLC (see page 5).

JBC Robot Control Unit — 12.1 Sniffer Mode Panel diagram (page 19)
Fig. 22 · 12.1 Sniffer Mode Panel
JBC Robot Control Unit — 12.1 Sniffer Mode Panel diagram (page 19)
Fig. 23 · 12.1 Sniffer Mode Panel

Serial Port (a): Select one Serial Port for PLC and the other Serial Port for the JBC Device.

Port configuration (b): You can change the Configuration Settings. Frame Detection (c): Click on Start, and if there is any communication between the two selected ports, the communication frames will be shown. Click on Stop to stop frame detection.

Frame Field (d): Communication frames will be displayed.

Clear Log (e): Click to clear the frame detection field.

Copy Log to Clipboard (f): Click to create a copy of the frames detected.

With Colours (g): Activate to have the data frames displayed in colour. This representation may facilitate the reading of data.

Ask about the JBC Robot Control Unit

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the JBC Robot Control Unit

Be the first to ask — other owners or our team will answer.

Original document

JBC Robot Control Unit manual PDF

19 pages·420 KB·Controller·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…