Benefits
Pre-programmed package eliminates the need • for custom programming


One package for one to three pumps provides • consistency for operators and technicians
Local Display/Keypad Operator Interface panel • for on-site system control
Alarm and historical data reporting for full • SCADA integration
Multiple pump scenarios allow flexibility to meet • a wide range of applications
Pump start/stop as well as VFD speed control •
Easy-to-use web page station configuration and • setup
Easily interfaces to field devices and sensors •
Single program offers performance and simplicity for monitoring and control of remote water and wastewater applications
Security and water quality functions can be • easily added as needed
Plant managers will take maximum advantage of the flexibility and maintenance personnel will ap preciate the simplicity of the Bristol ControlWave pump control application. All remote water and wastewater applications have the same require ments to automatically control one or more pumps to maintain level, pressure and/or flow. Some sites may also have the need to control chemical feed, measure rain level, and detect intrusion events. All of these are pre-programmed and available for use to customize for the specific site.
Remote tank level control •
Duplex Lift or Booster station •
Triplex Lift or Booster station •
This standard pre-programmed application lever ages our decades of experience monitoring and controlling remote pumps in a wide variety of water and wastewater sites in North America and through out the world. The standard application can be used with the appropriate Bristol® ControlWave® PLC/RTU, from Emerson Process Management to meet the I/O requirements at the various sites. The combined solution offers a cost effective system that is ready to deploy without the typical programming overhead.
When the application requires modifications or addi tions to the standard program, Bristol ControlWave Designer allows unlimited customization by your engineering staff or other integrators.
Well station • · Reservoir Control •

Analog outputs:
VFD speed control Chemical feed pump
Digital inputs:
Counter inputs:
Pump 1 status Pump Remote/Local
Station flow Rain gauge

Digital outputs:
Triplex Booster or Lift Station
Pump start Pump Stop
Digital inputs:
Analog inputs:
Pump 1, 2 & 3 status Pump 1, 2 & 3 Remote/Local 2 tank level DI Intrusion or Motion
Station flow Well drawdown Outlet pressure Chlorine residual Clearwell level or tank level

Digital outputs:
Pump 1, 2 & 3 start Pump 1, 2 & 3 Stop
Analog outputs:
VFD speed control Chemical feed pump
Analog inputs:
Station flow Inlet pressure Outlet pressure Chlorine residual Clearwell level or tank level
Counter inputs:
ControlWave MIcro PLC/RTU SCADA Package
Station flow Rain gauge
Duplex Booster or Lift Station
Analog outputs:
Digital inputs:
VFD speed control Chemical feed pump
Pump 1 & 2 status Pump 1 & 2 Remote/Local 2 tank level DI Intrusion or Motion
Counter inputs:

Station flow Rain gauge
Digital outputs:
Pump 1 & 2 start Pump 1 & 2 Stop
Analog inputs:
Station flow Inlet pressure Outlet pressure Chlorine residual Clearwell level or tank level

Historical Archive
The Bristol ControlWave Micro and ControlWave ExpressPAC integrated SCADA packages, from Emerson, are designed and built for out-of-the-box installation and startup. The assemblies are fully integrated units that combine the PLC/RTU with a variety of options commonly required in SCADA applications. These include a NEMA 4X rated en closure, power supply and battery backup options, termination options, display and operator input op tions, and wireless communication options.
Historical data is stored in three archive files in the ControlWave PLC/RTU flash memory. This ensures maximum data integrity even in the event of a SCADA communication network failure. The his torical data archives may be collected periodically on a scheduled or demand basis by the OpenBSI Harvester utility. This technique also minimizes communication bandwidth requirements significantly benefiting radio and cellular network architectures.
Daily Archive:

Stores 35 days of time-stamped minimums, maxi mums, averages and totals
Hourly Archive:
Stores hourly time-stamped minimums, maximums, averages and totals
Trend Archive:
The Trend Archive stores instantaneous values at a fixed period from one minute to sixty minutes.
ControlWave MIcro PLC/RTU SCADA Package
As mentioned earlier, the ControlWave pump control SCADA application is pre-programmed. The unit only needs site specific configuration through the easy-to-use set of web pages supplied with the ap plication software. These configuration web pages are accessible through the OpenBSI TechView utility.
The ControlWave SCADA packages with the pre- programmed pump controller application are ideal for integrating remote site measurement and control into the SCADA system.


Pump lead/lag and pump alteration
Pump interlock and permissive conditions
Manual and PID VFD Control
TechView allows easy connection to any ControlWave PLC/RTU through serial or Ethernet ports. The utility is essentially a web page browser that really simplifies menu navigation and PLC/RTU configuration.
Level control · Pressure control · Time control

The initial configuration setup is presented in a step- by-step procedure using a question and answer for mat. Once familiar with the procedures, individual configuration pages can easily be accessed rather than using the Q & A format.






Q & A Configuration


The configuration pages allow you to set the com munication address and parameters, select station control mode parameters, enter setpoints and alarm limits, modify zero and span for analog inputs, add permissives and interlocks, and perform pump startups.
A station overview display is also provided to show pump run status, local/remote operation, and instan taneous values of pressure, flow and level.
Setup and configuration may also be performed from the integral display/keypad on the ControlWave PLC/RTU SCADA package or via the SCADA system host HMI. All configuration parameters are made available to OPC servers for compatibility with our OpenEnterprise SCADA software as well as third party SCADA software packages.
I/O Configuration · Configuration Page · Loop Control Page

KPSI™ Submersible Level Transducers

Tank and wet well level measurement •
5 to 700 feet •
.05% to 1 % full scale accuracy •
Non-fouling diaphragm options for lift station • applications
4-20 mA or 0-5 V output •
AquaSensors™ Water Quality Instruments
The AquaSensors DataStick™ provides a cost-ef fective plug and play analytical measurement sys tem for continuous use in industrial environments. DataStick communicates with ControlWave via a preconfigured serial Modbus function block.
The ControlWave pump control application is available pre-installed in a ControlWave Micro or Express PLC/RTU. A modifiable version is avail able allowing program additions, but does not allow modifications to the pump control program itself. There is also a complete source version that allows unlimited modification of the pump control program. These three offerings provide the flexibility to meet the needs of wide range of users, technicians and engineers.
Direct measurement of pH, reagent free residual • chlorine, dissolved oxygen, ORP or turbidity
11” CPVC direct insertion probe •
10-30 Vdc,
Censar® Six-Cense® multiparameter in-line sensor measures in real time (pH, ORP, conductivity, dis solved oxygen, free chlorine, and temperature)
Direct insertion into pressurized main 2 inches • to 72 inches in diameter
The pump control SCADA package can be com bined with a variety of additional products that facili tate integration or provide even greater functionality.
Operates under working pressures up to 230 psi •
Reagent-free measurement of Chlorine •
Measures Monochloramine for plans using • chloramination
Process Measurement Transmitters Bristol 2808 & 3808
Low maintenance, low cost sensor replacement •
2808 analog pressure transmitter for tank level • measurement
Security Vision application package
3808 digital DP transmitter for flow • measurement
Pre and post event video capture and replay •
Pre-programmed function block provides all • video file/folder manipulation
OpenBSI Utility for collection and replay of • captured events
Two year warranty •
Local indicator option •
IP enabled network video camera with FTP • server
Facility entry access control and reporting •
Adjustable ranges • · High accuracy •

Related specification documents:
ControlWave Micro – 420ds5k.pdf ControlWave ExpressPAC - 420ds7c.pdf ControlWave Micro Enclosures – 420ds0d.pdf ControlWave Designer – 420ds3d.pdf Security Vision – 454ds11b.pdf OpenEnterprise – 450ds1b.pdf
The OpenEnterprise SCADA software provides a turnkey SCADA solution from field equipment to Supervisory Control, Management Reporting and Enterprise wide data distribution. OpenEnterprise is the tool that links Projects, Operations, Accounts and Management, making SCADA a part of the business process.
Real-time Relational Object Oriented Database •
Water Quality and SCADA security on the www.ControlWave.com web site.
Included Historian with backfill capability •
Advanced ‘state of the art’ graphics builder •
Complete specifications are available on the www.EmersonProcess.com/Remote web site.
Powerful reporting tools •
Alarm and Event Manager •
Open standards support for SQL, ODBC/ADO, • Java DBC, OPC OLE & HDA, DDE, VB
Thin client options for corporate and operational • users
OPC data access direct from database •
Fault tolerant and distributed servers over WAN • or LAN
© 2007 Remote Automation Solutions, division of Emerson Process Management. All rights reserved.
Bristol, Inc., Bristol Babcock Ltd, Bristol Canada, BBI SA de CV and the Flow Computer Division , are wholly owned subsidiaries of Emerson Electric Co. doing business as Remote Auto mation Solutions (“RAS”), a division of Emerson Process Management. FloBoss, ROCLINK, Bristol, Bristol Babcock, ControlWave, TeleFlow and Helicoid are trademarks of RAS. AMS, PlantWeb and the PlantWeb logo are marks of Emerson Electric Co. The Emerson logo is a trademark and service mark of the Emerson Electric Co. All other marks are property of their respective owners.
The contents of this publication are presented for informational purposes only. While every effort has been made to ensure informational accuracy, they are not to be construed as war ranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. RAS reserves the right to modify or improve the designs or specifications of such products at any time without notice. All sales are governed by RAS’ terms and conditions which are available upon request. RAS does not assume responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use and maintenance of any RAS product remains solely with the purchaser and end-user.
Emerson Process Management Remote Automation Solutions
Watertown, CT 06795 USA T 1 (860) 945-2200 Mississauga, ON 06795 Canada T 1 (905) 362-0880 Worcester WR3 8YB UK T 44 (1) 905-856950
OpenEnterprise SCADA Host
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.