EN
Emerson Process Management logo
Official user manual

Emerson Process Management Remote Terminal Unit (SCADA RTU)

6 pages·2.1 MB·Controller·PDF·ENDEFRITNLJA
Emerson Process Management Remote Terminal Unit (SCADA RTU)
Table of Contents 11 sections Integrated Pump Control SCADA RTU · Pre-Engineered Water and Wastewater Remote Pump Control Application Package · Benefits · Specifications · … ShowHide
Page 1 of the Emerson Process Management Remote Terminal Unit (SCADA RTU) user manual — Pre-Engineered Water and Wastewater Remote Pump Control Application Package
Page 1 · click to enlarge
Page 1

Integrated Pump Control SCADA RTU

Pre-Engineered Water and Wastewater Remote Pump Control Application Package

Benefits

Pre-programmed package eliminates the need • for custom programming

Emerson Process Management Remote Terminal Unit (SCADA RTU) — Pre-Engineered Water and Wastewater Remote Pump Control Application Package diagram (page 1)
Fig. 1 · Pre-Engineered Water and Wastewater Remote Pump Cont…
Emerson Process Management Remote Terminal Unit (SCADA RTU) — Pre-Engineered Water and Wastewater Remote Pump Control Application Package diagram (page 1)
Fig. 2 · Pre-Engineered Water and Wastewater Remote Pump Cont…

One package for one to three pumps provides • consistency for operators and technicians

Local Display/Keypad Operator Interface panel • for on-site system control

Alarm and historical data reporting for full • SCADA integration

Multiple pump scenarios allow flexibility to meet • a wide range of applications

Pump start/stop as well as VFD speed control •

Easy-to-use web page station configuration and • setup

Easily interfaces to field devices and sensors •

Single program offers performance and simplicity for monitoring and control of remote water and wastewater applications

Security and water quality functions can be • easily added as needed

Plant managers will take maximum advantage of the flexibility and maintenance personnel will ap preciate the simplicity of the Bristol ControlWave pump control application. All remote water and wastewater applications have the same require ments to automatically control one or more pumps to maintain level, pressure and/or flow. Some sites may also have the need to control chemical feed, measure rain level, and detect intrusion events. All of these are pre-programmed and available for use to customize for the specific site.

Remote tank level control •

Duplex Lift or Booster station •

Triplex Lift or Booster station •

This standard pre-programmed application lever ages our decades of experience monitoring and controlling remote pumps in a wide variety of water and wastewater sites in North America and through out the world. The standard application can be used with the appropriate Bristol® ControlWave® PLC/RTU, from Emerson Process Management to meet the I/O requirements at the various sites. The combined solution offers a cost effective system that is ready to deploy without the typical programming overhead.

When the application requires modifications or addi tions to the standard program, Bristol ControlWave Designer allows unlimited customization by your engineering staff or other integrators.

Well station • · Reservoir Control •

Page 2 of the Emerson Process Management Remote Terminal Unit (SCADA RTU) user manual — PLC/RTU
Page 2 · click to enlarge
Page 2

Specifications

Analog outputs:

VFD speed control Chemical feed pump

Digital inputs:

Counter inputs:

Pump 1 status Pump Remote/Local

Station flow Rain gauge

Emerson Process Management Remote Terminal Unit (SCADA RTU) — Specifications diagram (page 2)
Fig. 3 · Specifications

Digital outputs:

Triplex Booster or Lift Station

Pump start Pump Stop

Digital inputs:

Analog inputs:

Pump 1, 2 & 3 status Pump 1, 2 & 3 Remote/Local 2 tank level DI Intrusion or Motion

Station flow Well drawdown Outlet pressure Chlorine residual Clearwell level or tank level

Emerson Process Management Remote Terminal Unit (SCADA RTU) — Specifications diagram (page 2)
Fig. 4 · Specifications

Digital outputs:

Pump 1, 2 & 3 start Pump 1, 2 & 3 Stop

Analog outputs:

VFD speed control Chemical feed pump

Analog inputs:

Station flow Inlet pressure Outlet pressure Chlorine residual Clearwell level or tank level

Counter inputs:

ControlWave MIcro PLC/RTU SCADA Package

Station flow Rain gauge

Duplex Booster or Lift Station

Analog outputs:

Digital inputs:

VFD speed control Chemical feed pump

Pump 1 & 2 status Pump 1 & 2 Remote/Local 2 tank level DI Intrusion or Motion

Counter inputs:

Emerson Process Management Remote Terminal Unit (SCADA RTU) — Specifications diagram (page 2)
Fig. 5 · Specifications

Station flow Rain gauge

Digital outputs:

Pump 1 & 2 start Pump 1 & 2 Stop

Analog inputs:

Station flow Inlet pressure Outlet pressure Chlorine residual Clearwell level or tank level

PLC/RTU

Show 4 more labels / short text on this page
Well or Reservoir · ControlWave ExpressPAC · SCADA Package · ControlWave MIcro
Page 3 of the Emerson Process Management Remote Terminal Unit (SCADA RTU) user manual — Station Control Strategies:
Page 3 · click to enlarge
Page 3

SCADA Packages

Historical Archive

The Bristol ControlWave Micro and ControlWave ExpressPAC integrated SCADA packages, from Emerson, are designed and built for out-of-the-box installation and startup. The assemblies are fully integrated units that combine the PLC/RTU with a variety of options commonly required in SCADA applications. These include a NEMA 4X rated en closure, power supply and battery backup options, termination options, display and operator input op tions, and wireless communication options.

Historical data is stored in three archive files in the ControlWave PLC/RTU flash memory. This ensures maximum data integrity even in the event of a SCADA communication network failure. The his torical data archives may be collected periodically on a scheduled or demand basis by the OpenBSI Harvester utility. This technique also minimizes communication bandwidth requirements significantly benefiting radio and cellular network architectures.

Daily Archive:

Emerson Process Management Remote Terminal Unit (SCADA RTU) — SCADA Packages diagram (page 3)
Fig. 6 · SCADA Packages

Stores 35 days of time-stamped minimums, maxi mums, averages and totals

Hourly Archive:

Stores hourly time-stamped minimums, maximums, averages and totals

Trend Archive:

The Trend Archive stores instantaneous values at a fixed period from one minute to sixty minutes.

ControlWave MIcro PLC/RTU SCADA Package

Setup and Configuration

As mentioned earlier, the ControlWave pump control SCADA application is pre-programmed. The unit only needs site specific configuration through the easy-to-use set of web pages supplied with the ap plication software. These configuration web pages are accessible through the OpenBSI TechView utility.

The ControlWave SCADA packages with the pre- programmed pump controller application are ideal for integrating remote site measurement and control into the SCADA system.

Station Control Strategies:

Emerson Process Management Remote Terminal Unit (SCADA RTU) — Station Control Strategies: diagram (page 3)
Fig. 7 · Station Control Strategies:
Emerson Process Management Remote Terminal Unit (SCADA RTU) — Station Control Strategies: diagram (page 3)
Fig. 8 · Station Control Strategies:

Pump lead/lag and pump alteration

Pump interlock and permissive conditions

Manual and PID VFD Control

TechView allows easy connection to any ControlWave PLC/RTU through serial or Ethernet ports. The utility is essentially a web page browser that really simplifies menu navigation and PLC/RTU configuration.

Level control · Pressure control · Time control

Page 4 of the Emerson Process Management Remote Terminal Unit (SCADA RTU) user manual — SCADA Packages
Page 4 · click to enlarge
Page 4

The initial configuration setup is presented in a step- by-step procedure using a question and answer for mat. Once familiar with the procedures, individual configuration pages can easily be accessed rather than using the Q & A format.

Emerson Process Management Remote Terminal Unit (SCADA RTU) — SCADA Packages diagram (page 4)
Fig. 9 · SCADA Packages
Emerson Process Management Remote Terminal Unit (SCADA RTU) — SCADA Packages diagram (page 4)
Fig. 10 · SCADA Packages
Emerson Process Management Remote Terminal Unit (SCADA RTU) — SCADA Packages diagram (page 4)
Fig. 11 · SCADA Packages
Emerson Process Management Remote Terminal Unit (SCADA RTU) — SCADA Packages diagram (page 4)
Fig. 12 · SCADA Packages
Emerson Process Management Remote Terminal Unit (SCADA RTU) — SCADA Packages diagram (page 4)
Fig. 13 · SCADA Packages
Emerson Process Management Remote Terminal Unit (SCADA RTU) — SCADA Packages diagram (page 4)
Fig. 14 · SCADA Packages

Q & A Configuration

Emerson Process Management Remote Terminal Unit (SCADA RTU) — SCADA Packages diagram (page 4)
Fig. 15 · SCADA Packages
Emerson Process Management Remote Terminal Unit (SCADA RTU) — SCADA Packages diagram (page 4)
Fig. 16 · SCADA Packages

The configuration pages allow you to set the com munication address and parameters, select station control mode parameters, enter setpoints and alarm limits, modify zero and span for analog inputs, add permissives and interlocks, and perform pump startups.

A station overview display is also provided to show pump run status, local/remote operation, and instan taneous values of pressure, flow and level.

Setup and configuration may also be performed from the integral display/keypad on the ControlWave PLC/RTU SCADA package or via the SCADA system host HMI. All configuration parameters are made available to OPC servers for compatibility with our OpenEnterprise SCADA software as well as third party SCADA software packages.

I/O Configuration · Configuration Page · Loop Control Page

Page 5 of the Emerson Process Management Remote Terminal Unit (SCADA RTU) user manual — Products for expanded functionality
Page 5 · click to enlarge
Page 5

KPSI™ Submersible Level Transducers

Emerson Process Management Remote Terminal Unit (SCADA RTU) — Software components diagram (page 5)
Fig. 17 · Software components

Tank and wet well level measurement •

5 to 700 feet •

.05% to 1 % full scale accuracy •

Non-fouling diaphragm options for lift station • applications

4-20 mA or 0-5 V output •

AquaSensors™ Water Quality Instruments

The AquaSensors DataStick™ provides a cost-ef fective plug and play analytical measurement sys tem for continuous use in industrial environments. DataStick communicates with ControlWave via a preconfigured serial Modbus function block.

Software components

The ControlWave pump control application is available pre-installed in a ControlWave Micro or Express PLC/RTU. A modifiable version is avail able allowing program additions, but does not allow modifications to the pump control program itself. There is also a complete source version that allows unlimited modification of the pump control program. These three offerings provide the flexibility to meet the needs of wide range of users, technicians and engineers.

Direct measurement of pH, reagent free residual • chlorine, dissolved oxygen, ORP or turbidity

11” CPVC direct insertion probe •

10-30 Vdc,

Censar® Six-Cense® multiparameter in-line sensor measures in real time (pH, ORP, conductivity, dis solved oxygen, free chlorine, and temperature)

Products for expanded functionality

Direct insertion into pressurized main 2 inches • to 72 inches in diameter

The pump control SCADA package can be com bined with a variety of additional products that facili tate integration or provide even greater functionality.

Operates under working pressures up to 230 psi •

Reagent-free measurement of Chlorine •

Measures Monochloramine for plans using • chloramination

Process Measurement Transmitters Bristol 2808 & 3808

Low maintenance, low cost sensor replacement •

2808 analog pressure transmitter for tank level • measurement

Security Vision application package

3808 digital DP transmitter for flow • measurement

Pre and post event video capture and replay •

Pre-programmed function block provides all • video file/folder manipulation

OpenBSI Utility for collection and replay of • captured events

Two year warranty •

Local indicator option •

IP enabled network video camera with FTP • server

Facility entry access control and reporting •

Adjustable ranges • · High accuracy •

Page 6 of the Emerson Process Management Remote Terminal Unit (SCADA RTU) user manual — Software components
Page 6 · click to enlarge
Page 6

Related specification documents:

ControlWave Micro – 420ds5k.pdf ControlWave ExpressPAC - 420ds7c.pdf ControlWave Micro Enclosures – 420ds0d.pdf ControlWave Designer – 420ds3d.pdf Security Vision – 454ds11b.pdf OpenEnterprise – 450ds1b.pdf

The OpenEnterprise SCADA software provides a turnkey SCADA solution from field equipment to Supervisory Control, Management Reporting and Enterprise wide data distribution. OpenEnterprise is the tool that links Projects, Operations, Accounts and Management, making SCADA a part of the business process.

Real-time Relational Object Oriented Database •

Water Quality and SCADA security on the www.ControlWave.com web site.

Included Historian with backfill capability •

Advanced ‘state of the art’ graphics builder •

Complete specifications are available on the www.EmersonProcess.com/Remote web site.

Powerful reporting tools •

Alarm and Event Manager •

Open standards support for SQL, ODBC/ADO, • Java DBC, OPC OLE & HDA, DDE, VB

Thin client options for corporate and operational • users

OPC data access direct from database •

Fault tolerant and distributed servers over WAN • or LAN

© 2007 Remote Automation Solutions, division of Emerson Process Management. All rights reserved.

Bristol, Inc., Bristol Babcock Ltd, Bristol Canada, BBI SA de CV and the Flow Computer Division , are wholly owned subsidiaries of Emerson Electric Co. doing business as Remote Auto mation Solutions (“RAS”), a division of Emerson Process Management. FloBoss, ROCLINK, Bristol, Bristol Babcock, ControlWave, TeleFlow and Helicoid are trademarks of RAS. AMS, PlantWeb and the PlantWeb logo are marks of Emerson Electric Co. The Emerson logo is a trademark and service mark of the Emerson Electric Co. All other marks are property of their respective owners.

The contents of this publication are presented for informational purposes only. While every effort has been made to ensure informational accuracy, they are not to be construed as war ranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. RAS reserves the right to modify or improve the designs or specifications of such products at any time without notice. All sales are governed by RAS’ terms and conditions which are available upon request. RAS does not assume responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use and maintenance of any RAS product remains solely with the purchaser and end-user.

Emerson Process Management Remote Automation Solutions

Watertown, CT 06795 USA T 1 (860) 945-2200 Mississauga, ON 06795 Canada T 1 (905) 362-0880 Worcester WR3 8YB UK T 44 (1) 905-856950

Websitewww.EmersonProcess.com/Remote

OpenEnterprise SCADA Host

Ask about the Emerson Process Management Remote Terminal Unit (SCADA RTU)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Emerson Process Management Remote Terminal Unit (SCADA RTU)

Be the first to ask — other owners or our team will answer.

Original document

Emerson Process Management Remote Terminal Unit (SCADA RTU) manual PDF

6 pages·2.1 MB·Controller·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…