PHSK Small Preheater Set

This manual corresponds to the following references:
Packing List
The following items are included:

Small PCB Support 1 unit Ref. PHS-SA Small Preheater Unit 1 unit

Console 1 unit Ref. ACE-A
RJ45 Cable 1 unit Ref. 0019914
Power Cord 1 unit Ref. 0024092 (100V) 0023715 (120V) 0023714 (230V)



Thermocouple 2 unit Ref. PH218 Kapton Tape 1 unit Ref. PH217
Manual 1 unit Ref. 0026988


Fixing Brackets for Small PCB Support
Thermocouple Connectors x4 (Type K)
RJ12 Connector to Robot
RJ45 Connector to Console
Button for Foot Folding and Unfolding

2,8” Color TFT Screen Start / Stop

RJ45 Connector to Preheater Unit
Foot for Vertical Set Up

The Small PCB Support allows adjustment for 3 heights between the PCB and the Heating Area of the Preheater Unit.
Unscrew these knobs to place the support in the lowest level


Use the fixing brackets to place the support in the medium and the high level


To change the height to the highest level, proceed as follows:



The Small PCB Support lets you replace PCBs of the same batch fast and easily. Use the sliding guides to change the PCBs.
Placing another PCB Position it and tighten the sliding guide knobs.
Loosen one sliding guide, push the PCB against the sliding guide and lift out.



Place large PCBs on the 4 rubber caps

Removing the PCB

The Console offers an intuitive user interface which provides quick access to station parameters.

Instant Power Supplied to Heater
TC1 Current and Selected Temperature
Thermocouple Current Temp.
Thermocouple Selected Temp. and Mode · Control · Protection · Info
System notifications (Status Bar)
USB flash drive is connected.
Station is controlled by a PC.
General Work mode Profile editor
Station is controlled by a robot.
Station software update. Press INFO to start the process.
Available languages: English, Spanish, German, French, Italian, Portuguese, Japanese, Chinese, Russian and Korean.
Error. Press INFO for failure description, the type of error and how to proceed.
Station troubleshooting available on the product page at www.jbctools.com Troubleshooting

Select Thermocouples from the Work mode menu to set them up. The thermocouples (TC) can work in three diferent ways depending on what is needed.
· Control: the unit mantains the selected temperature. · Protection: the Heater Unit stops if the TC reaches the selected temperature. · Info: the TC temperature is shown in the work screen.
The TC1 is always working in Control mode for the Temperature mode as well as for Profiles mode. The temperature of each TC can also be selected from the work screen.

Fix with Kapton Tape

Control Thermocouple · Protection Thermocouple

Select Temp. mode from the Work mode menu. In this mode the heater unit maintains the selected temperature for the TC1 thermocouple as long as the other TC’s do not reach the control/protection temperature limit.
14:15
Instant Power Supplied to Heater
TC1 Current and Selected Temperature
Selected 120ºC
º C TC3
º C TC4
Thermocouple Selected Temp. and Mode · Control · Protection · Info
Thermocouple Current Temp.
P 100 º C 20
C P
Select Power mode from the Work mode menu. In this mode the heater unit maintains the selected power as long as the thermocouples do not reach the control/protection temperature limit.
14:15
Instant Power Supplied to Heater
Thermocouple Selected Temp. and MSode · Control · Protection · Info
º C TC2
º C TC3
º C TC4
Thermocouple current temp.
P 100 º C 20
P 100 º C 20
P 100 º C

Select Profile Mode from the Work Mode Menu. In this mode the heater unit regulates the temperature of the TC1 thermocouple according to the selected profile as long as the other TCs do not reach the control/protection temperature limit.
14:15
º C TC3
º C TC4
For repetitive jobs you running profiles without the Thermocouple (TC). In order to do so, the Teach profile mode has to be executed before running any profile. It can be executed from the Work mode menu if the Profiles mode is selected. Once the profile has been run to the end, the system has all the process data which you can save. Once it is saved, you can run this profile without connecting the Thermocouple (TC). The heating process will be the same as long as the same working conditions are respected.
The profiles which already have the data from the Teach profile are marked with this symbol
These profiles can be run either with or without the Thermocouples. It can be chosen from the Profiles mode work screen:
Profile Modes · Stop PROFILE1 200 · Teach Profile

The Profile editor can be opened from the main menu or from the Profiles mode work screen by pressing the ‘OK’ button. In this mode you can edit as many as 25 profiles of temperature.

· Add Point · Delete Point · Load Profile · Save Profile · Exit
Data for these Points
There are 3 profiles predefined by JBC: A, B and C. The difference between them is the number of steps: 2, 3 or 4. The thicker your PCB is and the more layers it contains, the more steps are needed to obtain a gradual warming. These profiles are not modifiable but can be used as a template to create your own profiles.
JBC-A 2 steps JBC-B 3 steps JBC-C 4 steps
5’ 8’ 5’30” 3’30” 8’
PCB Reference Specifications:
and 6 layers. FR4 1,6mm thick
and 2 layers.
and 6 layers.
Profiles set using the low position of the PHS-SA Support (28 mm in height between the PCB and the heating area).
Profiles set using the low position of the Support (28 mm in height between the PCB and the heating area).

By pressing Graphics in the main MENU, temperature of TC1 thermocouple and power fi gures in real time are displayed.


Switch Y Axis Between Power and Temperature
The following icons will be displayed on the screen’s status bar.
USB fl ash drive is connected.
Station software update. Press INFO to start the process.
Station is controlled by a PC.
Station is controlled by a robot.
Error. Press INFO for failure description, the type of error and how to proceed.
Graphics · Temperature (ºC)

Export Graphics Insert a USB flash drive into the USB-A connector to save your soldering process in csv format.
Export / Import Profiles Insert a USB flash drive into the USB-A connector to export / import profiles.

Working with Pedal
Press the pedal to start heating and press again to stop as if it was the button on the console. Once the Work Mode is set, the Heater Unit can work without the console using the pedal.

Pedal Ref. P-405 (not included)
Files · JBC Update File · Small Preheater Unit

Before carrying out maintenance or storage, always allow the equipment and the support to cool down.
- Check periodically that the Pre Heater is clean. - Use a damp cloth when cleaning. Alcohol can only be used to clean the metal parts.
- Only if it is absolutely necessary and if cleaning with isopropyl alcohol (IPA) is not enough, it is
recommended to use a scraper to remove dirt in the glass area.
- Replace any defective or damaged parts. Use original JBC spare parts only.
- Repairs should only be performed by a JBC authorized technical service.

It is imperative to follow safety guidelines to prevent electric shock, injury, fire or explosion.
- Do not use the units for any purpose other than PCB preheating. Incorrect use may cause fire.
- The mains cable must be plugged into approved bases. Make sure that it is properly grounded before use. When unplugging it, hold the plug, not the wire.
- The temperature of accessible surfaces may remain high after the unit is turned off. Handle with care.
- Do not leave the appliance unattended when it is on.
- Do not cover the ventilation grills. Heat can cause inflamable products to ignite.
- Heat can cause inflamable products to ignite even when out of sight.
- Be careful with the remains of liquid tin. In contact with skin, it can cause burns.
- Avoid flux coming into contact with skin or eyes to prevent irritation.
- Be careful with the smoke produced when soldering.
- Keep your workplace clean and tidy. Wear appropriate protection glasses and gloves when working to avoid personal harm.
- This appliance can be used by children over the age of eight as well as persons with reduced physical, sensory or mental capabilities or lacking experience provided that they have been given adequate supervision or instruction concerning use of the appliance and understand the hazards involved. Children must not play with the appliance.
- Maintenance must not be carried out by children unless supervised.

Small Preheater Set PHSE-9KB 100V. Input 100V 50/60Hz Fuse T8A PHSE-1KB 120V. Input 120V 50/60Hz Fuse T8A PHSE-2KB 230V. Input 230V 50/60Hz Fuse T4A
Small Preheater Unit - Maximum Power: 600W - Heating Area: 65 x 135 mm / 2.56 x 5.31 in - 1 zone 130 x 135 mm / 5.12 x 5.31 in - 2 zones - Ambient Operating Temperature: 10 - 40 ºC / 50 - 104 ºF - Temperature Range: 50 - 250 °C / 120 - 482 ºF - Temperature Measurement: Thermocouple type K - JBC Set Temperature Profiles: 3 profiles (2, 3 or 4 steps) - User Profiles: 20 (up to 6 steps for each) - Maximum Work Time: 600 min or indefinite - Dimensions / Weight: 195 x 288 x 41.5 mm / 1.74 kg (L x W x H) 7.68 x 11.34 x 1.63 in / 3.84 lb
Small PCB Support - Weight: 2 kg / 4.4 lb - Dimensions (Low Position): 267 x 259 x 75 mm (L x W x H) 10.5 x 10.2 x 3 in - Dimensions (High Position): 267 x 259 x 96 mm (L x W x H) 10.5 x 10.2 x 3.8 in - Max. PCB Dimension (Low Position): 180 x 175 mm / 7.09 x 6.89 in
Small Preheater Set - Total Net Weight: 4.8 kg / 10.6 lb - Total Package Dimensions / Weight: 368 x 368 x 195 mm / 5.8 kg (L x W x H) 14.5 x 14.5 x 7.7 in / 12.8 lb
Complies with CE standards. ESD protected housing.

Warranty JBC’s 2 year warranty covers this equipment against all manufacturing defects, including the replacement of defective parts and labour. Warranty does not cover product wear or misuse. In order for the warranty to be valid, equipment must be returned, postage paid, to the dealer where it was purchased. Get 1 extra year JBC warranty by registering here: https://www.jbctools.com/productregistration/ within 30 days of purchase.