Instruction/ maintenance manual of the product 1GR85A Vulcan-Hart
Go to page of 26
INSTALLATION & OPERATIONAL MANUAL 1GRA & GRAF SERIES GAS FRYERS VFRY18 & VFRY18F HDR FRYERS With KleenScreen PLUS ® Filtration Systems M O D E L S : 1GR45A ML-136647 1GR65A ML-136648 1GR8.
GRA, GRAF, & VFRY GAS FRYERS & VFRY SERIES HD FRYERS VULCAN-HART F-32 934 Rev. J (August 2012) -2- IMPORTANT FOR YOUR SAFETY THIS MANUAL HAS BEEN PREPARED FOR PERSONNEL QUALIFIED TO INSTALL GAS EQUIPMENT, WHO SHOULD PERFORM THE INITIAL FIELD START-UP AND ADJUSTMENTS OF THE EQUIPMENT COVERED BY THIS MANUAL.
GRA, GRAF, & VFRY GAS FRYERS & VFRY SERIES HD FRYERS VULCAN-HART F-32 934 Rev. J (August 2012) -3- TABLE OF CONTENTS IMPORTANT FOR YOUR SAFETY……………………………… ……….
GRA, GRAF, & VFRY GAS FRYERS & VFRY SERIES HD FRYERS VULCAN-HART F-32 934 Rev. J (August 2012) -4- INTRODUCTION GENERAL Vulcan Fryers are produced wit h quality workmanship and mate rial. Proper installation, usage and maintenance will result in year s of satisfactory performance.
GRA, GRAF, & VFRY GAS FRYERS & VFRY SERIES HD FRYERS VULCAN-HART F-32 934 Rev. J (August 2012) -5- Check that the followi ng have been included: Crumb Rack(s) Basket Hanger(s) Tank Brush Adjustable Casters (4) two locking, two non- locking for freestandi ng fryers.
GRA, GRAF, & VFRY GAS FRYERS & VFRY SERIES HD FRYERS VULCAN-HART F-32 934 Rev. J (August 2012) -6- Clearances: Minimum clearance from combusti ble construction: 6” (15 cm) from the sides of the fryer 6” (15 cm) from t he back of the fryer The fryer may be installed on combustible floors.
GRA, GRAF, & VFRY GAS FRYERS & VFRY SERIES HD FRYERS VULCAN-HART F-32 934 Rev. J (August 2012) -7- National Electrical Code, ANSI/NFPA-70 (latest edition). Copies may be obtained from The National Fire Protection Associ ation, Batterymarch Park, Quincy, MA.
GRA, GRAF, & VFRY GAS FRYERS & VFRY SER IES HD FRYERS VULCAN-H ART F-32 934 Rev. J (August 2012) -8- GAS CONNECTION All gas supply connections and any pipe joint compound must be resist ant to the action of propane gases. The gas inlet is located on the lower rear of the fryer.
GRA, GRAF, & VFRY GAS FRYERS & VFRY SER IES HD FRYERS VULCAN-H ART F-32 934 Rev. J (August 2012) -9- When installing a quick disconnect you must also install a means for limiting the movement of the fryer. This device wi ll prevent the gas line or quick disconnect from being strained.
GRA, GRAF, & VFRY GAS FRYERS & VFRY SER IES HD FRYERS VULCAN-H ART F-32 934 Rev. J (August 2012) -10- the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.2, as applicable. Electrical diagram located on inside of door.
GRA, GRAF, & VFRY GAS FRYERS & VFRY SER IES HD FRYERS VULCAN-H ART F-32 934 Rev. J (August 2012) -11- Rinse fryer and accessories t horoughly and drain the fryer. Wipe tank completely dry with a soft, clean cloth. FILLING TANK WITH SHORTENING Close the drain valve.
GRA, GRAF, & VFRY GAS FRYERS & VFRY SERIES HD FRYERS VULCAN-HART F-32 934 Rev. J (August 2012) -12- Fry Basket Guidelines Do not overfill baskets. (See fry basket capacity below) Carefully lower basket into oil. When frying doughnuts and fritters, turn product only once during frying.
GRA, GRAF, & VFRY GAS FRYERS & VFRY SER IES HD FRYERS VULCAN-H ART F-32 934 Rev. J (August 2012) -13- Solid State Knob Control Indicator Lights (On/Start/Heating) Temperature Knob Control Melt.
GRA, GRAF, & VFRY GAS FRYERS & VFRY SER IES HD FRYERS VULCAN-H ART F-32 934 Rev. J (August 2012) -14-.
GRA, GRAF, & VFRY GAS FRYERS & VFRY SER IES HD FRYERS VULCAN-H ART F-32 934 Rev. J (August 2012) -15- EXTENDED SHUTDOWN 1. Open the door to the fryer. Press the power switch to the OFF position. 2. Thoroughly drain the fryer. Refer to DRAINING THE FRYER.
GRA, GRAF, & VFRY GAS FRYERS & VFRY SER IES HD FRYERS VULCAN-H ART F-32 934 Rev. J (August 2012) -16- DRAINING THE TANK 1. Open the door to the fryer. The power must remain ON for the fryer to filter correctly. 2. Insert the drain extension into t he drain valve.
GRA, GRAF, & VFRY GAS FRYERS & VFRY SER IES HD FRYERS VULCAN-H ART F-32 934 Rev. J (August 2012) -17- 10. Close the drain valve and add shorteni ng. Follow the FILLING TANK WITH SHORTENING procedure in this manual. The fryer is now ready for use.
GRA, GRAF, & VFRY GAS FRYERS & VFRY SER IES HD FRYERS VULCAN-H ART F-32 934 Rev. J (August 2012) -18- KleenScreen Plus ® Filtration System Installation and Operational Manual for “AF” Mod.
GRA, GRAF, & VFRY GAS FRYERS & VFRY SER IES HD FRYERS VULCAN-H ART F-32 934 Rev. J (August 2012) -19- Filtering Instructions for KleenScreen PLUS ® Fryers General The KleenScreen PLUS ® filtration system filters the oil as it is pumped back into its’ respective tank(s).
GRA, GRAF, & VFRY GAS FRYERS & VFRY SER IES HD FRYERS VULCAN-H ART F-32 934 Rev. J (August 2012) -20- Fully assembled filter screen assembly: F i g .
GRA, GRAF, & VFRY GAS FRYERS & VFRY SER IES HD FRYERS VULCAN-H ART F-32 934 Rev. J (August 2012) -21- INSTRUCTIONS TO REMOVE & REPLACE KLEENSCREE N PLUS ® FILTER ENVELOPE FOR ABSOLUTE FILTRATION & MAXIMUM FLOW RATE WE REC OMMEND YOU CHANGE YOUR FILTER ENVELOPES AT EVERY OIL CHANGE (10-14 D AYS DEPENDING ON OIL USAGE).
GRA, GRAF, & VFRY GAS FRYERS & VFRY SER IES HD FRYERS VULCAN-H ART F-32 934 Rev. J (August 2012) -22- Operation Hot oil and parts can cause burns. Use care when operating, cleaning and servicing the fryer. Spilling hot frying compound can cause severe burns.
GRA, GRAF, & VFRY GAS FRYERS & VFRY SER IES HD FRYERS VULCAN-H ART F-32 934 Rev. J (August 2012) -23-.
GRA, GRAF, & VFRY GAS FRYERS & VFRY SERIES HD FRYERS VULCAN-HART F-32 934 Rev. J (August 2012) -24- FILTERING TIP: Open the filtering drawer approximately 1” to allow any oil in the re turn line to run back into the filter pan. This will take about 30 seconds to complete.
GRA, GRAF, & VFRY GAS FRYERS & VFRY SER IES HD FRYERS VULCAN-H ART F-32 934 Rev. J (August 2012) -25- BOIL OUT PROCEDURE: Use the Boil Out By-Pass™ drai n extension allowing the boil out solution to exit the fry t ank without using the filtering system.
GRA, GRAF, & VFRY GAS FRYERS & VFRY SER IES HD FRYERS VULCAN-H ART F-32 934 Rev. J (August 2012) -26- MAINTENANCE Hot oil and hot parts can cause burns. Use care when operating, cleani ng, and servicing the fry er. Spilling hot fryer com pound can cause severe burns.
An important point after buying a device Vulcan-Hart 1GR85A (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Vulcan-Hart 1GR85A yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Vulcan-Hart 1GR85A - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Vulcan-Hart 1GR85A you will learn all the available features of the product, as well as information on its operation. The information that you get Vulcan-Hart 1GR85A will certainly help you make a decision on the purchase.
If you already are a holder of Vulcan-Hart 1GR85A, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Vulcan-Hart 1GR85A.
However, one of the most important roles played by the user manual is to help in solving problems with Vulcan-Hart 1GR85A. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Vulcan-Hart 1GR85A along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center