INSTALLATION & OPERATIONAL MANUAL GRD & GRC SERIES GAS FRYERS With KleenScreen PLUS ® Filtration Systems M O D E L S : 1GR45D ML-136411 1GR45C ML-136414 1GR65D ML-136412 1GR65C ML-136415 1GR8.
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-312 14 Rev. D (March 2008 ) -2- IMPORTANT FOR YOUR SAFETY THIS MANUAL HAS BEEN PREPARED FOR PERSONNEL QUALIFIED TO INSTALL GAS EQUIPMENT, WHO SHOULD PERFORM THE INITIAL FIELD START-UP AND ADJUSTMENTS OF THE EQUIPMENT COVERED BY THIS MANUAL.
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-312 14 Rev. D (March 2008 ) -3- TABLE OF CONTENTS IMPORTANT FOR YOUR SAFETY……………………………… ……….
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-312 14 Rev. D (March 2008 ) -4- INTRODUCTION GENERAL Vulcan Fryers are produced wit h quality workmanship and mate rial. Proper installation, usage and maintenance will result in year s of satisfactory performance.
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-312 14 Rev. D (March 2008 ) -5- UNPACKING This fryer was carefully inspected before l eaving the factory. Upon acceptance of the shipment, the transportation company assume s full responsibility for safe delivery.
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-312 14 Rev. D (March 2008 ) -6- Clearances Minimum clearance from combustible construction: 6” (15 cm) from the sides of the fryer 6” (15 cm) from t.
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-312 14 Rev. D (March 2008 ) -7- In the commonwealth of Massachusetts all gas appliances vented through a ventilation hood or exhaust system with a damper or with a power means of exhaust shall comply with 248 CMR.
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-312 14 Rev. D (March 2008 ) -8- GAS CONNECTION All gas supply connections and any pipe joint compound must be resist ant to the action of propane gases. The gas inlet is located on the lower rear of the fryer.
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-312 14 Rev. D (March 2008 ) -9- When installing a quick disconnect you must also install a means for limiting the movement of the fryer. This device will prevent the gas line or quick disconnect from being strained.
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-312 14 Rev. D (March 2008 ) -10- LEVELING THE FRYER Check the level of the fryer by placing a le vel on top of the fryer after gas connections have been made. Ensure that the fryer is level front-to-back and side-to-side in the final installed position.
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-312 14 Rev. D (March 2008 ) -11- FILLING TANK WITH SHORTENING Close the drain valve. Fill the fryer tank wit h liquid shortening. Shortening level should be between the min and max lines in the fryer tank.
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-312 14 Rev. D (March 2008 ) -12- Fry Basket Guidelines Do not overfill baskets. (See table fo r recommended basket capacities below) Carefully lower basket into oil. When frying doughnuts and fritters, turn product only once during frying.
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-312 14 Rev. D (March 2008 ) -13- Programming the Solid State Control TURNING OFF THE FRYER 1. Turn the thermostat OFF. 2. To keep the pilot lit, turn the gas valve to “L” in Pilot. 3. To shut off all gas to the system, in cluding the pilot, turn the gas valve knob to OFF.
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-312 14 Rev. D (March 2008 ) -14- Programming the Computer Control.
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-312 14 Rev. D (March 2008 ) -15- FILTERING THE OIL Hot oil and hot parts can cause burns. Use care when operating, cleanin g, and servicing the fryer. Filter shortening at least once a day. 1. Do NOT turn off the power to the fryer.
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-312 14 Rev. D (March 2008 ) -16- 3. Direct the drain spout into the container that you want to drain the shortening into. 4. Open the drain valve. The oil will drain in to the container. When the container is full or the fryer tank is empt y, close the drain valve.
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-312 14 Rev. D (March 2008 ) -17- 8. Turn OFF the power to the fryer. Dr ain the tank according to DRAINING THE TANK. Rinse thoroughly with clear, hot wa ter. All traces of cleaner must be removed. Dry t he tank thoroughly.
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-312 14 Rev. D (March 2008 ) -18- KleenScreen Plus ® Filtration System Installation and Operational Manual for “DF” and “CF” Models GRD/CF and 2XGD/.
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-312 14 Rev. D (March 2008 ) -19- Filtering Instructions for KleenScreen PLUS ® Fryers General The KleenScreen PLUS ® filtration system filters t he oil as it is pumped back into its’ respective tank(s). Only one tank can be dr ained and filtered at a time.
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-312 14 Rev. D (March 2008 ) -20- Fully assembled filter screen assembly: F i g . 2 Secure Tube with Suction Tube Clip Filter Screen Lays Flat On Bottom of Filter Pan Fig.
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-312 14 Rev. D (March 2008 ) -21- INSTRUCTIONS TO REMOVE & REPLACE KLEENSCREEN PLUS ® FILTER ENVELOPE FOR ABSOLUTE FILTRATION & MAXIMUM FLOW RA TE WE RECOMME ND YOU CHANGE YOUR FILTER ENVELOPES AT EVERY OIL CHANGE (10-14 DAYS DEPENDING ON OIL USAGE).
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-312 14 Rev. D (March 2008 ) -22- Operation Hot oil and parts can cause burns. Use care when operating, cleaning and servicing the fryer. Spilling hot frying compound can cause severe burns. Do not move fryer without draining all frying compound from the tank.
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-312 14 Rev. D (March 2008 ) -23- Filtering Instructions for KleenScreen PLUS ® Fryers with Solid State Controls.
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-312 14 Rev. D (March 2008 ) -24- Filtering Instructions for KleenScreen PLUS ® Fryers with Computer Controls.
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-312 14 Rev. D (March 2008 ) -25- FILTERING TIP: Open the filtering drawer approximately 1” to allow any oil in the re turn line to run back into the filter pan. This will take about 30 seconds to complete.
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-312 14 Rev. D (March 2008 ) -26- BOIL OUT PROCEDURE: Use the Boil Out By-Pass™ drai n extension allowing the boil out solution to exit the fry tank without using the filtering system. Do not allow water to run through the motor / pump.
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-312 14 Rev. D (March 2008 ) -27- MAINTENANCE Hot oil and hot parts can cause burns. Use care when operating, clean ing, and servicing the fryer. Spilling hot fryer com pound can cause severe burns. Do not move fryer without draining all frying compound from the tank.
GRDF / GRCF SERIES GAS FRYERS VULCAN-HART F-312 14 Rev. D (March 2008 ) -28- OPEN PROBE – If an open probe is detected, the heat demand is disabled and any running cooking cycles are cancelled.
An important point after buying a device Vulcan-Hart 1GR65C (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Vulcan-Hart 1GR65C yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Vulcan-Hart 1GR65C - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Vulcan-Hart 1GR65C you will learn all the available features of the product, as well as information on its operation. The information that you get Vulcan-Hart 1GR65C will certainly help you make a decision on the purchase.
If you already are a holder of Vulcan-Hart 1GR65C, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Vulcan-Hart 1GR65C.
However, one of the most important roles played by the user manual is to help in solving problems with Vulcan-Hart 1GR65C. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Vulcan-Hart 1GR65C along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center