Vent Free L.P.& NATURAL
OWNER ’ S OPERATION AND INSTALLATION MANUAL
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. WHAT TO DO IF YOU SMELL GAS l Do not try to light any appliance. l Do not touch any electrical switch; do not use any
SSU320RHL-GB
SSU320RHN-B
SSU320RHL-B
SSU320RHN-G
SSU320RHL-G
phone in your building. l Immediately call your gas supplier from a neighbor’s
SSU320RHL-S
phone. Follow the gas supplier’s instructions. l If you cannot reach your gas supplier, call the
fire department. Installation and service must be performed by a qualified installer, service agency, or local gas supplier.
This appliance may be installed in an aftermarket*, permanently located manufactured (mobile) home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.
WATER VAPOR: A BY-PRODUCT OF UNVENTED ROOM HEATERS Water vapor is a by-product of gas combustion. An unvented room heater produces approximately one (1) ounce (30)ml of water for every 1,000BTU’S (. 3KW’S) OF gas input per hour, Refer to page 7.
5 Musick 4600 Highlands Parkway S.E.
CA 92618 Smyrna GA 30080
Nanjing PRO-COM Electric Appliance Co., Ltd.
Consumer : Please retain these instruction for future use.
#6 Chuangye Road, High New Tech. Zone,
Great Bridge Road North, Nanjing, 210061, China.
Installer: Please leave these instructions with the consumer.
* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer.
PC-SL035A058-0505
Irvine Suite# D/E


10. Keep all air openings in front and bottom of heater clear and free of debris. This will insure enough air for proper combustion. 11. If heater shuts off. Do not relight un- til you provide fresh, outside air. If heater keeps shutting off, have it serviced. 12. Do not run heater: l Where flammable liquids or vapors are used or stored. lUnder dusty conditions. 13. Before using furniture polish, wax, carpet cleaner, or similar products, turn heater off. If heated, the vapors from these products may create a white powder residue within burner box or on adjacent walls or furniture. 14. Do not use this heater to cook food or burn paper or other objects. 15. Do not use heater if any part has been under water. lmmediately call a qualified service technician to in- spect the room heater and to re- place any part of the control system and any gas control which has been under water. 16. Turn off and unplug heater and let cool before servicing. Only a quali- fied service person should service and repair heater. 17. Operating heater above elevations of 4,500 feet could cause pilot outage. 18. Do not operate heater if any log is broken. Do not operate heater if a log is chipped (dime-sized or larger). 19. To prevent performance problems, do not use Propane/LP fuel tank of less than 100 lbs. capacity.
Do not place clothing or other flammable material on or near the appliance. Never place any objects in the heater.
Carefully supervise young children when they are in the room with the heater.
do not use any phone in your building. lImmediately call your gas supplier
You must operate this heater with the heater door with screen in place. Make sure the heater door with screen is in place before running heater.
from a neighbor’s phone. Follow the gas supplier’s instructions. lIf you cannot reach your gas supplier, call the fire department. 4. This heater shall not be installed in a bedroom or bathroom. 5. Do not use this heater as a wood- burning heater. Use only the logs provided with the heater. 6. Do not add extra logs or ornaments such as pine cones, vermiculite, or rock wool. Using these added items can cause sooting. Do not add lava rock around base. Rock and debris could fall into the control area of heater. After servicing, always re- place screen before operating heater. 7. This heater is designed to be smokeless. If logs ever appear to smoke, turn heater off and call a qualified service person. Note: Dur- ing initial operation, slight smoking could occur due to log curing and heater burning manufacturing residues. 8. To prevent the creation of soot, fol- low the instructions in Cleaning and Maintenance. 9. This heater needs fresh air ventila- tion to run properly. This heater has an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS shuts down the heater if not enough fresh air is available. See Air for Combustion and Ventilation, pages 5 through 6. If heater keeps shutting off, see Troubleshooting, pages 17 through 19.
Keep the appliance area clear and free from combustible materials, gasoline, and other flammable va- pors and liquids.
WATER VAPOR: A BY-PRODUCT OF UNVENTED ROOM HEATERS Water vapor is a by-product of gas combustion. An unvented room heater produces approximately one (1) ounce (30ml) of water for every 1,000 BTU’s (.3kw’s) of gas input per hour. Unvented room heaters are intended as supplemental heat (a room) rather that a primary heat source (an entire house) in most supplemental heat applications, the water vapor does not create a problem, in most applications the water vapor enhances the low hu- midity atmospheres experienced dur- ing cold weather. The following steps will help insure that water vapor does not become a problem. 1. Be sure the heater is sized properly for the application, including ample combustion air and circulation of the air. 2. If high humidity is experienced, a dehumidifier may be used to help lower the water vapor content of the air. 3. Do not use an unvented room heater as the primary heat source.

MANUAL OVERRIDE CONTROL SYSTEM This heater has two operation functions: Remote Control and Manual Override Control. The Remote Control has a transmitter, which re- quires three AAA batteries and elec- tric power outlet to operate. If no elec- tric power is available, then you can operate the heater by manual override.
State of Massachusetts: The instal- lation must be made by a licensed plumber or gas fitter in the Common- wealth of Massachusetts. Sellers of unvented propane or natu- ral gas-fired supplemental room heat- ers shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit. In the state of Massachusetts, unvented propane or natural gas-fired space heaters shall be prohibited in bedrooms and bathrooms.
QUALIFIED INSTALLING AGENCY Installation and replacement of gas piping, gas utilization equipment or ac- cessories and repair and servicing of equipment shall be performed only by a qualified agency. The term “qualified agency” means any individual, firm, corporation, or company that either in person or through a representative is engaged in and is responsible for (a) the installation, testing, or replacement of gas piping or (b) the connection, installation, testing, repair, or servicing of equipment; that is experienced in such work; that is familiar with all pre- cautions required, and that has com- plied with all the requirement of the au- thority having jurisdiction.
In the State of Massachusetts the gas cock must be a “T” handle type. The State of Massachusetts requires that a flexible appliance connector cannot exceed three feet in length.
This heater is designed for vent free operation. Some state and local codes prohibit the use of vent-free gas heaters. lnstall and use heater with care. Fol- low all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code, ANSI Z223.1, also known as NFPA 54*. *Available from: American National Standards lnstitute, lnc. 1430 Broadway New York, NY 10018 National Fire Protection Association, lnc. Batterymarch Park Quincy. MA 02269
PRODUCT FEATURES
SAFETY PILOT This heater has a pilot with an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS/pilot is a required fea- ture for vent-free room heaters. The ODS/pilot shuts off the heater if there is not enough fresh air.
AUTOMATIC IGNITION SYSTEM This heater is equipped with an auto- matic control system. This system requires no matches, or batteries to light heater.
THERMOSTATIC HEAT CONTROL MODULE This heater has a control module with a thermostat sensing bulb. SET TEMP with remote control. This results in the greatest heater comfort and may re- sult in lower gas bills.
Figure 1- Vent Free Gas Stove

Confined and Unconfined Space The National Fuel Gas Code, ANSI Z223. 1 defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all ap- pliances installed in that space. Rooms communicating directly with the space in which the appliances are installed*, through openings not furnished with doors, are considered a part of the un- confined space.
Unusually Tight Construction The air that leaks around doors and windows may provide enough fresh air for combustion and ventilation. However, in buildings of unusually tight construction, you must provide addi- tional fresh air. Unusually tight construction is defined as construction where: a) Walls and ceilings exposed to the
outside atmosphere have a continu- ous water vapor retarder with a rat- ing of one perm (6×10-11kg per pa- sec-m2) or less with openings gasketed or sealed and b) Weather stripping has been added
The following are excerpts from National Fuel Gas Code, NFPA 54/ANSI Z223. 1, Section 5.3, Air for Combustion and Ventilation. All spaces in homes fall into one of the three following ventilation classifications: 1. Unusually Tight Construction 2. Unconfined Space 3. Confined Space The information on pages 5 through 6 will help you classify your space and provide adequate ventilation.
on openable windows and doors and c) Caulking or sealants are applied to
This heater shall not be installed in a confined space or unusually tight con- struction unless provisions are pro- vided for adequate combustion and ventilation air.
areas such as joints around window and door frames, between sole plates and floors, between wall ceil- ing joints, between wall panels, at p e ne t r at i o ns f or p lu m b in g , electrical, and gas lines, and at other openings. If your home meets all of the three cri- teria above, you must provide additional fresh air. See Ventilation Air From Outdoors. If your home does not meet all of the three criteria above, proceed to Deter- mining Fresh-Air Flow For Heater Location.
* Adjoining rooms are communicat- ing only if there are doorless passage- ways or ventilation grills between them.
DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION Determining if You Have a Confined or Unconfined Space Use this worksheet to determine if you have a confined or unconfined space. Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms. 1. Determine the volume of the space (length×width×height). Length×Width×Height= cu.ft. (volume of space) Example: Space size 20ft. (length)×16ft.(width)×8ft. (ceiling height)=2560cu. ft. (volume of space) If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these rooms to the total
volume of the space. 2. Divide the space volume by 50 cubic feet to determine the maximum Btu/Hr the space can support. (volume of space)÷50 cu. ft.=(Maximum Btu/Hr the space can support) Example: 2560 cu. ft. (volume of space)÷50 cu.ft.=51.2 or 51,200(maximum Btu/Hr the space can support)

3. Add the Btu/Hr of all fuel burning appliances in the space. Vent-free heater Btu/Hr Gas water heater* Btu/Hr Gas furnace Btu/Hr Vented gas heater Btu/Hr Gas heater logs Btu/Hr Other gas appliances* + Btu/Hr Total = Btu/Hr *Do not include direct-vent gas appliances. Direct-vent draws combustion air from the outdoors and vents to the outdoors. 4. Compare the maximum Btu/Hr the space can support with the actual amount of Btu/Hr used. Btu/Hr (maximum the space can support) Btu/Hr (actual amount of Btu/Hr used) Example: 51,200 Btu/Hr(maximum the space can support) 56,000 Btu/Hr(actual amount of Btu/Hr used) The space in the above example is a confined space because the actual Btu/Hr used is more than the maximum Btu/Hr the space can support. You must provide additional fresh air. Your options are as follows: A. Rework worksheet, adding the space of an adjoining room. If the extra space provides an unconfined space, remove door to adjoining room or add ventilation grills between rooms. See Ventilation Air From Inside Building. B. Vent room directly to the outdoors. See Ventilation Air From Outdoors. C. Install a lower Btu/Hr heater, if lower Btu/Hr size makes room unconfined.
If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support, the space is an unconfined space. You will need no additional fresh air ventilation.
Ventilation Air From lnside Building
This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 2). You can also remove door into adjoining room (see option 3, Figure 2). Follow the National Fuel Gas Code. NFPA 54/ANSI Z223.1, Section 5.3, Air for Com- bustion and Ventilation for required size of ventilation grills or ducts.
Ventilation Air From Outdoors
Provide extra fresh air by using ventilation grills or ducts. You must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces. Follow the National Fuel Gas Code, NFPA 54/ ANSI Z223.1, Section 5.3, Air for Combustion and Ven- tilation for required size of ventilation grills or ducts.
Figure 2 -Ventilation Air from Inside Building
Figure 3 -Ventilation Air from Outdoors

NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your primary heat- ing system. Do not install this heater as your primary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help cir- culate the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source.
Figure 4 -Minimum Clearance to Wall and Ceiling
CLEARANCES TO COMBUSTIBLES Carefully follow the instructions below. This stove is a freestanding unit designed to set directly on the floor.
If heater is installed directly on carpeting, tile or other combustible material, other than wood flooring, the heater shall be installed on a metal or wood panel extending the full width and depth of the heater.
CHECK GAS TYPE Be sure your gas supply is right for your heater. Otherwise, call dealer where you bought the heater for proper type heater.

Minimum Wall and Ceiling Clearances (see Figure 4) A. Clearances from outermost point of
stove top to any combustible side wall should not be less than 12 inches. B. Clearances from outermost point
of stove top to any combustible back wall should not be less than 6 i n c h e s ( l n c l u d e s c o r n e r installations). C. Clearances from the stove top to the
ceiling should not be less than 48 inches.
INSTALLATION ITEMS NEEDED Before installing heater, make sure you have the items listed below. l piping (check local codes) l sealant (resistant to propane/LP gas) l equipment shutoff valve* l test gauge connection* l sediment trap l tee joint l pipe wrench l flexible gas hose. (Check local codes)
*A CSA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional CSA design-certified equipment shutoff valve from your dealer.
The installer must supply an external regulator. The external regulator will reduce incoming gas pressure. If you do not reduce incoming gas pressure, heater regulator damage could occur. lnstall external regulator with the vent pointing down as shown in Figure 6. Pointing the vent down protects it from freezing rain or sleet.
Figure 5 - Gas Regulator Location For Gas inlet Connection

LP Models: 11”-14” W.C. supply pressure Gas supplier provides external regulator for propane gas.
Figure 8 - Equipment Shutoff Valve
Pressure Testing Gas Supply Piping System Test Pressures In Excess Of 1/2 PSIG(3.5kPa) 1. Disconnect heater with its appliance main gas valve (control valve) and equipment shutoff valve from gas supply piping system. Pressures in excess of 1/2 PSIG will damage heater regulator. 2. Cap off open end of gas pipe where equipment shutoff valve was connected. 3. Pressurize supply piping system by either using compressed air or open- ing gas supply tank valve. 4. Check all joints of gas supply piping system. Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak. 5. Correct all leaks at once. 6. Reconnect heater and equipment shutoff valve to gas supply. Check re- connected fittings for leaks.
We recommend that you install a sedi- ment trap in supply line as shown in Figure 7. Locate sediment trap where it is within reach for cleaning. Install in piping system between fuel supply and heater. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into heater controls. If sediment trap is not installed or is installed incorrectly, heater may not run properly.
Figure 6 - External Regulator With
NG Models: 5”-10.5” W.C. supply pressure Gas supplier provides external regu- lator for natural gas.
* Purchase the optional CSA design- certified equipment shutoff valve from your dealer. ** Minimum inlet pressure for purpose of input adjustment.
In the State of Massachusetts the gas cock must be a T handle type. The State of Massachusetts re- quires that a flexible appliance con- nector cannot exceed three feet in length.
Test Pressures Equal To or Less Than 1/2 PSIG(3.5 kPa) 1. Close equipment shutoff valve (see Figure 8). 2. Pressurize supply piping system by either using compressed air or open- ing natural supply tank valve. 3. Check all joints from gas meter to equipment shutoff valve (see Figure 9). Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak.
Installation must include an equip- ment shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 7).
Pressure Testing Heater Gas Connections 1. Open equipment shutoff valve (see Figure 8). 2. Open gas supply tank valve. 3. Make sure control knob of heater is in the OFF position. 4. Check all joints from equipment shutoff valve to control valve (see Fig- ure 9). Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak.
Figure 7 - Gas Connection
Vent Pointing Down

Figure 10- Installing Log Set
FIG (5) STEP 4: Place log 4 on log 1 and log 3, as shown. Note: Log 4 will contact inside of heater.
Figure 9 - Checking Gas Joints
FIG (6) STEP 5: Insert the recessed hole on the bottom of log 5 onto the pin on log 1, with the other end of log 5 placed on log 4, as shown.
FIG (2) STEP 1: Install log 1 onto the two slots in the rear plate.
FIG (7) STEP 6: Place log 6 on log 1 and log 3. Note: Log 6 will contact inside of heater.
FIG (3) STEP 2: Install log 2 onto the two slots in the middle plate.
It is very important to install the logs exactly as instructed. Do not modify logs. Only use logs supplied with heater.
Make sure log sits flat on firebox floor.
FIG (4) STEP 3: Insert the two pins on the bot- tom of log 3 into the two holes on fire- box floor.
FIG (8) STEP 7: Insert the recessed hole on the bottom of log 7 onto the pin on log 2, with the other end placed on log 3.
(Top View)

C. Use only your hand to push control.
Never use tools. If the appliance does not operate, don't try to repair it, call a qualified service technician or gas supplier. Force or attempted repair may result in a fire or explosion. D. Do not use this appliance if any part
Note: If operating by remote control, you must set the Control Knob on ELECTRIC position. (See Figure 11) Do not set the control knob between the locked position, otherwise there will be no power to the heater. 1. STOP! Read the safety information above. 2. Disconnect or turn off all electric power to heater. 3. This appliance is equipped with an ignition device which automatically lights the pilot. Do not try to light the pilot by hand. 4. Wait five (5) minutes to clear out any gas. Then smell for gas around heater including near floor. If you smell gas, STOP! Follow “B” in the safety information above. If you don’t smell gas, go to the next step. 5. Plug into a properly grounded three- prong receptacle, and install three AAA batteries in remote. A high pitch sound will occur and red power light on front of heater will be lit. 6. Make sure Control Knob is in Electric Position. 7. Point remote at bottom front of heater, press IGN/OFF button, an electric spark will ignite the pilot, and green light on front of heater will be lit. Note: When operating heater for the
has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been un- der water.
Figure 11 - Manual ON/OFF Button Location
(With access panel removed)
A. This appliance is equipped with an
ignition device which automatically lights the pilot. Do not try to light the pilot by hand.
B. BEFORE LIGHTING smell all
around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.
Figure 12 - On/Off Switch Function of Manual ON/OFF Button and
first time, the ignition period may be 30 seconds or longer. This will al- low air to exit from the gas system.
WHAT TO DO IF YOU SMELL GAS l Do not try to light any appliance. l Do not touch any electrical switch; do
If your remote transmitter is lost or does not function, you can press the Manual ON/OFF Button on front of heater in order to manually operate your heater. (See Figure 11)
not use any phone in your building. l Immediately call your gas supplier
front burner. If pilot does not stay lit, contact a qualified service person or gas supplier for repairs. Note: If the
from a neighbor’s phone. Follow the gas supplier’s instructions. l If you cannot reach your gas supplier,
Note: To operate your heater the ON/ OFF switch on back of heater must be in the ON position. The RED light on the front of heater indicates there is electrical power to your heater when the ON/OFF switch is in the ON position. The GREEN light on the front of heater indicates the pilot light is ON. (See Figure 12)
appears on the control board, press the
call the fire department.
button, then press LOCK button to unlock.
Power ON/OFF Switch

Continued
symbol will appear on the LCD. 2.Key-press unlocking: Press ▼, then press LOCK button to unlock.
on and off. MAN: Burner operates continuously. 9. If the appliance will not operate, fol- low the instructions “To Turn Off Gas To Appliance” and call your service technician or gas supplier.
Fig 15 - Control board
OPERATING FAN Press FAN button for desired fan operation. AUTO: Blower will come on several minutes after burner comes on and will go off several minutes after burner goes off. MAN: Blower operates continuously. OFF: Blower is off.
to change to the scheduled time, then press the TIMER button again, the TIMER starts timing and the TIMER will flash and the green operation light flashes. Burner will au- tomatically come on at set time.
We provide the manual control sys- tem just in case of power shortage. Install battery for Manual Ignitor: 1. Unscrew the ignitor cap. 2. Insert a AAA type battery with its an- ode (“+”) pointing out. 3. Screw the ignitor cap back. Note: We recommend that the battery be taken out of the ignitor when the power supply gets right.
to change to the scheduled time, then press the TIMER button again, the TIMER starts timing and the TIMER will flash and the green operation flashes. Burner will au- tomatically shut off at set time.
Fig 13 - Front of Remote Control
SETTING TEMPERATURE With burner is on “Auto” position, press
to change to the desired temperature.
If power is off, you can operate the fireplace manually. 1. STOP! Read the safety information on page 11. 2. Check that gas supply to heater is on. 3. Open bottom front access panel. 4. Push in gas Control Knob slightly and turn clockwise
Fig 14 - Back of Remote Control
TO APPLIANCE Shut off heater 1. Press the IGN/OFF button. 2. Set Switch on OFF position or un- plug the electric power to the heater. (See Figure 12)
to the OFF position. If Control Knob is on ELEC- TRIC position, press in the Control Knob and turn counterclockwise
PILOT/IGN to “OFF” unless knob is pushed in slightly. Do not force.
Press CLOCK button for hours or minutes. Press
for correct time. Press CLOCK button again to set time.

TO APPLIANCE
Push in gas Control Knob slightly and turn clockwise
the OFF position. Do not force.
When electric power is available and electric operation is desired, turn clock- wise
to OFF position for one minute. Then press down knob and rotate clock- wise
to PI- LOT/IGN and depress for five (5) seconds. NOTE: The first time that the
to ELECTRIC position.
Do not operate between locked position.
heater is operated after connect- ing the gas supply, the control knob should be depressed for about thirty (30) seconds. This will allow air to bleed from the gas system. 7. With Control Knob pressed in, push and release the ignitor button. This will light the pilot. If needed, keep pressing ignitor button until pilot lights. 8. Keep Control Knob depressed for ten (10) seconds after lighting pilot. If pilot goes out, repeat steps 6, 7 and 8. 9. Turn counterclockwise
PROCEDURE (match light) 1. Open front door. 2. Follow steps 1 through 5 under MANUAL OPERATING Lighting Instructions. 3. With Control Knob in PILOT/IGN position, strike match, and hold near pilot. Press in Control Knob, pilot should light. 4. Keep Control Knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release Control Knob. Fol- low step 9 under MANUAL OPER- ATING Lighting Instructions.
to “ON” position. Do not operate between locked positions.
Figure 16 - Manual Control

INSPECTING FLAME PATTERN Check pilot flame pattern and burner flame patterns often. PILOT FLAME PATTERN Figure 17 shows a correct pilot flame pattern. Figure 18 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool. When the thermocouple cools, the heater will shut down. If pilot flame pat- tern is incorrect, as shown in Figure 18. l Turn heater off (see TO TURN OFF GAS TO APPLIANCE) l See troubleshooting
DISCONNECT WIRING OR CONTROL MODULE 1. Remove screws from the rear con- trol panel, take out thermostat sens- ing bulb from the clip, then discon- nect the wires from control module. 2. Remove two screws and hex nuts, securing control module. When installing, reverse the steps above. (See Figure 21 and Figure 25)
Figure 19 - Correct Flame Pattern
with heater set to High Flame
Figure 21 - Control Module Access
Figure 20 - Incorrect Flame Pattern
with heater set to High Flame
DISCONNECT FAN 1. Remove screws from the fan bracket panel, pull the fan bracket panel out to remove. Disconnect two wires from fan T-stat Switch. 2. Mark or tag each wire removed for its exact reconnection. Remove the four screws from the fan. When installing, reverse the steps above. (See Figure 22 and Figure 25)
TENANCE
Figure 17 - Correct Pilot Flame
Figure 22 - Fan Access
CLEANING BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLE We recommend that you clean the unit every 2,500 hours of operation or every three months.
Figure 18 - Incorrect Pilot Flame Pattern
BURNER FLAME PATTERN Figure 19 shows a correct burner flame pattern. Figure 20 shows an incorrect burner flame pattern. If burner flame is incorrect: l Turn heater off (see TO TURN OFF
The primary air inlet holes allow the proper amount of air to mix with the gas. This provides a clean burning flame. Keep these holes clear of dust, dirt, lint, and pet hair. Clean these air inlet holes prior to each heating season. Blocked air holes will create soot. We recommend that you clean the unit every three months during opera- tion and have heater inspected yearly by a qualified service person.
GAS TO APPLIANCE) l See troubleshooting
Pattern

We recommend you keep the burner and pilot assembly clean and free of dust and dirt. To clean these parts we recommend using compressed air no greater than 30 PSI. Your local computer store, hardware store, or home center may carry compressed air in a can. You can use a vacuum cleaner in the blow position. If using com- pressed air in a can, please follow the directions on the can. If you don't fol- low directions on the can, you could damage the pilot assembly. 1. Shut off the unit, including the pilot. Allow the unit to cool for at least thirty minutes. 2 . Inspect burner, pilot and primary air inlet holes on injector holder for dust and dirt (See Figure 23). 3 . B l o w a i r t h r o u g h t h e ports/slots and holes in the burner. 4. Check the injector holder located at the end of the burner tube again. Remove any large particles of dust, dirt, lint, or pet hair with a soft cloth or vacuum cleaner nozzle. 5. Blow air into the primary air holes on the injector holder. 6. In case any large clumps of dust have now been pushed into the burner repeat steps 3 and 4. Clean the pilot assembly also. A yel- low tip on the pilot flame indicates dust and dirt in the pilot assembly. There is a small air inlet hole about two inches from where the pilot flame comes out of the pilot assembly (see Figure 24). With the unit off, lightly blow air through the air inlet hole. You may blow through a drinking straw if com- pressed air is not available.
Air Passageways l Use a vacuum cleaner or pressur-
ized air to clean. Exterior l Use a soft cloth dampened with a
mild soap and water mixture. Wipe the cabinet to remove dust. Logs l If you remove logs for cleaning, re-
fer to Installing Logs to properly re- place logs. l Replace logs if broken or chipped
Figure 24 - Pilot Air Inlet Hole
(dime size or larger).
MAIN BURNER Periodically inspect all burner flame holes with the heater running. All slotted burner flame holes should be open with yellow flame present. All round burner flame holes should be open with a small blue flame present. Some burner flame holes may become blocked by debris or rust, with no flame present. If so, turn off heater and let cool. Either remove blockage or replace burner. Blocked burner flame holes will create soot.
Figure 25 - Override Control System Diagram
Figure 23 - Burner Primary Air
Inlet

PARTS NOT UNDER WARRANTY Contact authorized dealers of this product. If they can’t supply original re- placement part(s) call PRO-COM’s toll- free number (877)886-5989.
ACCESSORIES Purchase these heater accessories from your local dealer. If they can not supply these accessories, contact PRO-COM for information. You can also write to the address listed on the front of this manual.
Use only original replacement parts. This will protect your warranty cover- age for parts replaced under warranty.
TECHNICAL SERVICE For questions about installation, operation, or troubleshooting, contact PRO-COM toll -free at (877)886-5989.
Contact authorized dealers of this product. If they can't supply original replacement part(s) call the number on the back of manual. When contacting your dealer or PRO-COM, have ready: l Your name l Your address l Model and serial numbers of your heater l How heater was malfunctioning l Type of gas used (Propane/LP or Natural gas/NG) l Purchase date l Warranty card. Usually, we will ask you to return the defective part to the factory.
SPECIFICATIONS
SSU320RHL-GB SSU320RHL-B SSU320RHL-G
SSU320RHN-GB SSU320RHN-B SSU320RHN-G SSU320RHN-S
SSU320RHL-S
Btu (Variable) 32,000 32,000 Gas Type LP Gas Natural Gas Ignition Automatic or Electronic Automatic or Electronic Manifold Pressure 9" W.C. 4" W.C. Inlet Gas Pressure (In. of water)* Maximum 14" 10.5" Minimum 11" 5" Dimensions, Inches (H×W×D) Heater 26 1/8"×42 5/16” ×16 7/8" 26 1/8"×42 5/16” ×16 7/8" Carton 18 7/8"×35 7/16” ×30” 18 7/8"×35 7/16” ×30” Weight, lbs Stove 108 108 Shipping 117 117 Volts 120 120
*For purposes of input adjustment
Watts 32 32

l Shut off gas supply. l Do not try to light any appliance. l Do not touch any electrical switch; do not use any phone in your building. l Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. l If you cannot reach your gas supplier, call the fire department.
POSSIBLE CAUSE
REMEDY
No spark when IGN/OFF is pressed
Spark at ODS/pilot but no ignition
ODS/pilot has flame but continues to spark

POSSIBLE CAUSE
REMEDY
ODS/pilot has flame but burner does not light
Delayed ignition at burner
Burner backfiring during combustion
Slight smoke or odor during initial op- eration
Dark residue on logs or inside of fire- place
Heater produces a clicking/ticking noise just after burner is lit or shut off
White powder residue forming within burner box or on adjacent walls or fur- niture

POSSIBLE CAUSE
REMEDY
Heater produces unwanted odors
Heater shuts off in use (ODS operates)
Gas odor exists even when heater is shut off
Gas odor during combustion
Moisture/condensation on windows