Instruction manual Page 4 - 8 IMPORTANT: Read and understand all instructions before using.
Guide dutilisation Page 9 - 13 IMPORTANT: Lire et comprendre toutes les instructions avant de démarrer les travaux.
Manual de instrucciones Página 14 - 18 IMPORTANTE: Lea y comprende todas las instrucciones antes de usar.
456003_003





18 Protect the power cord against heat, oil and sharp edges. 19 Check the plug and power cord regularly and have them replaced by a qualified technician if damaged. 20 Do not lift or carry the appliance by its handles using a crane hook or lifting gear. 21 Use only accessories approved by Festool (see the Festool Catalog).
READ ALL INSTRUCTIONS BEFORE USING THIS APPLIANCE !
To reduce the risk of fire, electric shock, or injury: 1 Do not leave this appliance unattended when plugged in. Unplug from outlet when not in use and before servicing. 2 To reduce the risk of electric shock Do not expose to rain. Store indoors. 3 Do not allow to be used as a toy. Close attention is necessary when used by or near children or animals. 4 Use only as described in this manual. Use only manufacturers recommended attach- ments. 5 Do not use with damaged power cord or plug. If the appliance is not working as it should, has been dropped, damaged, left outdoors, or immersed in or dropped into water, return it to a service center. 6 Do not pull or carry by the power cord, use power cord as a handle, close a door on power cord, or pull power cord around sharp edges or comers. Do not run appliance over power cord. Keep power cord away from heated surfaces. 7 Do not unplug by pulling on power cord. To unplug, grasp the plug, not the cord. 8 Do not handle plug or appliance with wet hands. 9 Do not put any object into the appliance openings. Do not use the appliance with any opening blocked; keep openings free of dust, lint, hair, and anything that may impede airflow. 10 Keep hair, loose clothing, fingers, and all parts of body away from openings and moving parts. 11 Turn off all controls before unplugging. 12 Use extra care when cleaning on stairs. 13 Do not use this appliance to vacuum flammable or combustible liquids such as gasoline, or vacuum in areas where these may be present. 14 Connect to a properly grounded outlet only. See Grounding Instructions. 15 Do not vacuum anything that is burning or smoking, such as cigarettes, matches, or hot ashes. Do not use this appliance to extract flammable or explosive dusts (such as magnesium, aluminum, etc.). Risk of explosion! 16 Do not use without dust bag and/or filters in place. 17 Do not use to vacuum up caustic or aggressive liquids (e.g. acids, alkalis, solvents).
Various dust created by power sanding, sawing, grinding, drilling and other construction activities contains chemicals known (to the State of California) to cause cancer, birth defects or other reproductive harm. Some examples of these chemicals are: lead from lead-based paints, crystalline silica from bricks and cement and
other masonry products, and arsenic and chromium from chemically-treated
lumber. The risk from these exposures varies, depen- ding on how often you do this type of work. To reduce your exposure to these chemicals: work in a well ventilated area, and work with approved safety equipment, such as dust masks that are specially designed to filter out microscopic particles.

This appliance must be grounded. If it should malfunction or break down while in use, grounding provides a path of least resistance for the electric current and reduces the risk of electric shock to the operator. This appliance has a power cord with equipment-grounding conductor and grounding plug. The plug must be inserted into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.
Improper connection of the equipment-grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service person if you are in doubt as to whether the outlet is properly grounded.
Do not modify the plug provided with the appliance if it will not fit the outlet, have a proper outlet installed by a qualified electrician.
This appliance is rated more than 15 amperes and is for use on a circuit having a nominal rating of 120 volts, and is factory- equipped with a specific electric cord and plug to permit connection to a proper electric circuit.

Make sure that the appliance is connected to an outlet having the same configuration as the plug. No adapter should be used with this appliance. If the appliance must be reconnected
for use on a different type of electric circuit, the reconnection must be made by qualified service personnel.
1 Technical data Power consumption 350 - 1,200 W Connected load to appliance plug socket max. 1,200 W Total connected load max.
(vacuum cleaner and plug socket) 2,400 W Volume flow (air) max., turbine 228 m3/h (8.2 cu.ft./h) Vacuum max., turbine 23,000 Pa Filter surface 14,000 cm2 (2,170 sq.in.) Suction hose, diameter x length 27 mm x 3.5 m (1.06 in. x 11.48 ft.) Dimensions L x W x H:
CT 22 E 625 x 380 x 440 mm (24.6 x 15 x 17.3 in.) CT 33 E 625 x 380 x 500 mm (24.6 x 15 x 19.7 in.) Container capacity:
CT 22 E / CT 33 E 22 l (5.7 gal.) / 33 l (8.6 gal.) Weight:
CT 22 E / CT 33 E 12 kg (26.4 lbs) / 14.5 kg (32 lbs) Power cable length 7.5 m (24.6 ft.) Protection type IP X4
The specified illustrations can be found at the beginning of the operating instructions.
b) Switch position Auto: The appliance plug socket is live. The cleaner motor starts only when the tool connected to the appliance plug socket is switched on.
2 Intended use The vacuum cleaners are designed for use as specified for the aspiration and evacuation of non-noxious dusts, dirt, sand, shavings etc.. The vacuum cleaners are designed as specified for vacuuming water. The vacuum cleaners are designed in accordance with IEC 60335-1 and IEC 60335- 2-69 for a higher loading in industrial use. The user is solely responsible for any damage or accident should the machine be used for other than its intended purpose.
Before turning the switch to the Auto position, ensure that the tool connected to the appliance plug socket is switched off. 3.3 Suction force regulator (1.9) The suction force regulator can be used to vary the suction capacity. This permits a precise adaptation to different substances to be picked up. 3.4 Connecting an electric tool Observe the maximum connected load on the appliance plug socket (see Technical Data)! Connect the electric tool to the appliance plug socket (1.6).
3 Appliance preparation and initial operation
3.1 Electrical connection The operating voltage shown on the rating plate must correspond to the voltage of the mains power supply. Make sure that the vacuum cleaner is switched off when you plug the power cable in. 3.2 On/off switch (1.8) In position 0 the vacuum cleaner is switched off and the appliance plug socket (1.6) is dead. Two modes of operation are possible: a) Switch position MAN: The cleaner motor starts immediately. The appliance plug socket is dead.
Make sure that the electric tool is switched off when plugging it in and unplugging it. 3.5 Connecting a compressed-air tool When the compressed-air module (1.4, Order No. 452 829) is fitted, the automatic cut-in of the appliance also operates in conjunction with compressed-air tools. We also recommend fitting of the VE supply unit (Order No. 452 797). The supply unit filters and oils the compressed air and allows the air pressure to be regulated.

An IAS connecting piece (Order No. 454 757) is available for connecting Festool compressed- air tools with the IAS system. To ensure trouble-free functioning of the automatic cut-in, the operating pressure of the tool must be 6 bar.
In order to conduct these static charges to earth, the extraction units are provided with an antistatic system as a standard feature. However, antistatic hoses and accessories have to be used in this case. 4.4 Temperature control To prevent over-heating, a temperature control device switches the vacuum cleaner off before reaching a critical motor temperature is reached Ù let the vacuum cleaner cool down for about 5 minutes. If it does not then switch on again automatically, consult a Festool customer service centre.
Make sure that the compressed- air tool is switched off when plugging it in and unplugging it!
4 Application A systainer can be fixed on the shelf (1.3) with the two clamps (1.2). Tools or accessories can also be stowed on the shelf and in the storage compartments (1.7, not with CT 22 E). A hose coupling (1.1, Order No. 487 072) can be plugged into the opening (1.5). The suction hose is connected to the tool from above with the hose coupling. Alternatively, a hose clip (order No. 452 998) can be fitted for coiling the suction hose. The wheels can be blocked by the brakes (2.8), thus preventing the vacuum cleaner from rolling away unexpectedly. The push handle (2.11, Order No. 452 921) makes the vacuum cleaner easier to move. Accessories (e.g. vacuum accessories) can be fixed to the push handle batten (2.9). An air blast is obtained by inserting a suction hose in the blast opening (2.7). 4.1 Vacuuming dry materials Before using the vacuum cleaner to evacuate dry substances, a filter bag must always be inserted in the container. Then the evacuated material can be disposed off easily. The filter element becomes damp after evacuating liquids. A damp filter element suffers more wear and tear if it is used for dry materials. Accordingly, the filter element should be dried or replaced with a dry one before dry operation. 4.2 Vacuuming liquids The filter bag has to be removed before evacuating liquids. We recommend use of a special wet filter (Order No. 452 924). When the maximum filling level is reached, a level indicator (2.12) automatically interrupts extraction.
5.1 Opening/closing the vacuum cleaner - Open retaining clamps (2.2) , - Raise upper part (2.4) until support catch (2.5) engages. Follow the reverse order to close the appliance. You must raise the upper part slightly before depressing or disengaging the support. 5.2 Changing the filter
During the following procedure, take care not to raise dust more than is un- avoidable. a) Changing filter bag Order No.: CT 22 E: 452 970 CT 33 E: 452 971 - Open the vacuum cleaner, - Remove the used filter bag (3.4): see printed text on filter bag, - Dispose of the used filter bag in accordance with statutory requirements, - Thoroughly clean the dirt container (2.10) and the space (3.1) for suction turbine (wipe down with a damp cloth), - Insert new filter bag: see printed text on filter bag. Important: Press the filter bag sleeve (3.3) firmly onto the dust extraction fitting (3.2)! - Close the vacuum cleaner.
b) Changing the filter element Order No.: 452 923 - Open the vacuum cleaner, - Remove the used filter element (2.3): see printed text on the filter element packaging, - Dispose of the used filter element in a sealed, dust-tight bag in accordance with statutory requirements,
Do not evacuate combustible liquids! If foam or liquid escapes, stop work immediately and empty the dirt container (see 5.4). 4.3 The antistatic system (AS) Friction in the suction hose causes electrostatic charges which can result in unpleasant electric shocks for the operator.
5 Operation

- Thoroughly clean dirt container (2.10) and space (3.1) for the suction turbine (wipe down with a damp cloth), - Fit a new filter element: see printed text on the filter element packaging, - Close vacuum cleaner.
8 Accessories, filter The accessory and filter order number can be found in your Festool catalogue or on the Internet under www.festool.com
Conditions of 1+2 Warranty You are entitled to a free extended warranty (1 year + 2 years = 3 years) for your Festool power tool. Festool shall be responsible for all shipping costs during the first year of the warranty. During the second and third year of the warranty the customer is responsible for shipping the tool to Festool. Festool will pay for return shipping to the customer using UPS Ground Service. All warranty service is valid 3 years from the date of purchase on your receipt or invoice. Festool Limited Warranty This warranty is valid on the pre-condition that the tool is used and operated in compliance with the Festool operating instructions. Festool warrants, only to the original consumer purchaser, that the specified tool will be free from defects in materials and workmanship for a term of one year from the date of procurement. Festool makes no other warranty, express or implied, for Festool portable power tools. No agent, representative, distributor, dealer or employee of Festool has the authority to increase or otherwise change the obligations or limitations of this warranty. The obligations of Festool in its sole discretion under this warranty shall be limited to the repair or replacement of any Festool portable power tool that is found to be defective as packaged with the User Manual. Excluded from coverage under this warranty are: normal wear and tear; damages caused by misuse, abuse or neglect; damage caused by anything other than defects in material and workmanship. This warranty does not apply to accessory items such as circular saw blades, drill bits, router bits, jigsaw blades, sanding belts, and grinding wheels. Also excluded are wearing parts, such as carbon brushes, lamellas of air tools, rubber collars and seals, sanding discs and pads, and batteries. Festool portable power tools requiring replacement or repair are to be returned with the receipt of purchase to Festool (call 800- 554-8741 for address details). IN NO EVENT SHALL FESTOOL BE LIABLE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY, EXPRESSED OR IMPLIED WHATSOEVER.
5.3 Cleaning the filter element To clean, move the handle (2.1) to and fro about 10 times. N.B.: You need to clean the filter element only if you use the vacuum cleaner without a filter bag. 5.4 Emptying the dirt container (2.10)
Always remove the upper part of the vacuum cleaner before emptying the dirt container! - Open the vacuum cleaner, - Raise the upper part slightly, depress the support (2.5), - Raise the upper part to the stop (vertical position), - Remove the upper part by moving it forwards horizontally, - Empty the dirt container,
- Replace the upper part. Make sure that both upper-part pins are fully inserted in the recesses (1.10). - Close the vacuum cleaner.
6 After finishing work - Switch off the cleaner and pull the plug of the mains lead out of the plug socket. - Wind up the mains lead (2.6). - Empty dirt tank. - Clean the vacuum cleaner inside and outside by suction and wiping. - Deposit the appliance in a dry room, safe from unauthorised use.
7 Maintenance and care
Always remove the mains plug from the socket before carrying out any maintenance work! Any maintenance and repair work requiring an opening of the motor housing may only be carried out by an authorised customer service workshop. A safety test is to be carried out at least once a year by the manufacturer or an instructed person, e.g. for possible damage to the filter and leaks in the appliance, and to ensure that the control devices are functioning.
9 Warranty

ALL WARRANTIES IMPLIED BY STATE LAW, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE HEREBY LIMITED TO THE DURATION OF THREE YEARS. Some states in the U.S. and some Canadian provinces do not allow the limitations on how long an implied warranty lasts, so the above limitation may not apply to you. With the
exception of any warranties implied by state or province law as hereby limited, the foregoing express limited warranty is exclusive and in lieu of all other warranties, guarantees, agreements and similar obligations of Festool. This warranty gives you specific legal rights and you may also have other rights which vary from state to state in the U.S. and province to province in Canada.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.