EN
Festool logo
Official user manual

Festool CT 33 (CT 33 E HEPA)

26 pages·316 KB·Vacuum Cleaner·PDF·ENDEITNLJA
Festool CT 33 (CT 33 E HEPA)
Table of Contents 39 sections CT 22 E HEPA CT 33 E HEPA · Contents · Electrical Safety · Safety Rules · … ShowHide
Page 1 of the Festool CT 33 (CT 33 E HEPA) user manual — CT 22 E HEPA CT 33 E HEPA
Page 1 · click to enlarge
Page 1
Festool CT 33 (CT 33 E HEPA) — CT 22 E HEPA CT 33 E HEPA diagram (page 1)
Fig. 1

CT 22 E HEPA CT 33 E HEPA

Festool CT 33 (CT 33 E HEPA) — CT 22 E HEPA CT 33 E HEPA diagram (page 1)
Fig. 2

Instruction manual Page 4 - 9 IMPORTANT: Read and understand all instructions before using.

Guide d’utilisation Page 10 - 16 IMPORTANT: Lire et comprendre toutes les instructions avant de démarrer les travaux.

Manual de instrucciones Página 17 - 23 IMPORTANTE: Lea y comprende todas las instrucciones antes de usar.

469 621_003

Page 2 of the Festool CT 33 (CT 33 E HEPA) user manual — CT 22 E HEPA CT 33 E HEPA
Page 2 · click to enlarge
Page 2
Page 2 of the Festool CT 33 (CT 33 E HEPA) user manual — CT 22 E HEPA CT 33 E HEPA
Page 3 of the Festool CT 33 (CT 33 E HEPA) user manual — CT 22 E HEPA CT 33 E HEPA
Page 3 · click to enlarge
Page 3
Page 3 of the Festool CT 33 (CT 33 E HEPA) user manual — CT 22 E HEPA CT 33 E HEPA
Page 5 of the Festool CT 33 (CT 33 E HEPA) user manual — Vacuum Cleaner Safety Rules
Page 5 · click to enlarge
Page 5

or under the infl uence of drugs, alcohol, or medi- cation. A moment of inattention while operating vacuum cleaner may result in serious personal injury. Avoid accidental starting. Be sure vacuum cleaner and tool switches are OFF before plugging in or putting vacuum cleaner switch into power tool activation mode or fi lter cleaning mode. Do not keep power tool plugged into the vacuum cleaner’s power tool outlet during normal vacuuming. Plug- ging in vacuum cleaners or tools that have the switch ON invites accidents. Do not overreach. Keep proper footing and balance both for you and the vacuum cleaner at all times. Use extra care when cleaning on stairs. Proper footing and balance enables bet- ter control of the vacuum cleaner in unexpected situations. Do not vacuum burning, smoking or smol- dering things like cigarettes, matches or hot ashes. Fire inside the vacuum cleaner tank may occur. Do not use to vacuum fl ammable liquids, alcohol, gases, or explosive dusts, like gas- oline or other fuels, lighter fl uid, varnish, polyurethane coatings, cleaners, oil-based paints, natural gas, hydrogen, coal dust, magnesium dust, grain dust, or gun powder. Electric motors create sparks which may ignite the dust or fumes. Dress properly. Do not wear loose clothing or jewelry. Contain long hair. Keep your hair, clothing, and gloves away from mov- ing parts. Loose clothes, jewelry, or long hair can be caught in moving parts, hose, and suction nozzles. Keep handles dry, clean and free from oil and grease. Do not hold the hose against any body parts during operation. Use safety equipment. Always wear eye and hearing protection. Dust mask, non-skid safety shoes, hard hat, or hearing protection must be used for appropriate conditions. Not suitable to vacuum hazardous or toxic substances or dusts e.g. asbestos. The fi lters will not be able to capture all particles and may exhaust them back into the environment.

Disconnect the plug from the power source before making any adjustments, changing accessories, or storing the vacuum cleaner. Such preventive safety measures reduce the risk of starting the vacuum cleaner accidentally. Never connect a tool with a rating greater than the maximum amperes listed on the receptacle. This vacuum cleaner has a power tool outlet for use in conjunction with other appliances such as sanders, jigsaws and planers; tools with greater ratings may cause a fi re. Do not vacuum dust when liquid/fl uid is contained in the vacuum cleaner tank. Do not vacuum liquids/fl uids when dust is in the tank. In either case empty the tank and/or remove dust bag before use so that dust does not cake and harden inside the tank. Dry fi lters completely after wet vacuuming or use a second dry fi lter set for dust vacu- uming. Damp or wet fi lters will cake with dust or develop mold or mildew. Store idle vacuum cleaner out of reach of children and other untrained persons. Vacuum cleaners are dangerous in the hands of untrained users. Maintain vacuum cleaner with care. Properly maintain vacuum cleaner to keep hose un- obstructed. Do not put any object into open- ings. Do not use with any opening blocked; keep free of dust, lint, hair and anything that may reduce air fl ow. Any alteration or modifi - cation is a misuse and may result in a dangerous condition. Check for misalignment or binding of mov- ing parts, breakage of parts, and any other condition that may affect the vacuum clean- ers operation. If damaged, have the vacuum cleaner serviced before using. Poorly main- tained vacuum cleaners cause many accidents. Develop a periodic maintenance schedule for your vacuum cleaner. Use only accessories that are recommended by the manufacturer for your model. Accesso- ries that may be suitable for one vacuum cleaner may become hazardous when used on another vacuum cleaner.

Service

Only qualifi ed repair personnel must perform vacuum cleaner service. Service or mainte- nance performed by unqualifi ed personnel could result in a risk of injury. For example: internal wires may be misplaced or pinched, safety guard return springs may be improperly mounted. When servicing a vacuum cleaner, use only identical replacement parts. Follow instruc- tions in the Maintenance section of this

Vacuum Cleaner Safety Rules

Vacuum cleaner Care

Do not use vacuum cleaner if switch does not turn it ON or OFF. Any vacuum cleaner that cannot be controlled with the switch is dangerous and must be repaired.

Page 6 of the Festool CT 33 (CT 33 E HEPA) user manual — Intended use
Page 6 · click to enlarge
Page 6

manual. Use of unauthorized parts or failure to follow the Maintenance Instructions may create a risk of electric shock or injury. Certain cleaning agents such as gasoline, carbon tetrachloride, ammonia, etc. may damage plastic parts.

  • crystalline silica from bricks and cement and other masonry products, and
  • arsenic and chromium from chemically-treated lumber. The risk from these exposures varies, depending on how often you do this type of work.

Various dust created by power sand- ing, sawing, grinding, drilling and other construc- tion activities contains chemicals known (to the State of California) to cause cancer, birth defects or other reproductive harm. Some examples of these chemicals are: • lead from lead-based paints,

To reduce your exposure to these

chemicals: work in a well ventilated area, and work with approved safety equipment, such as dust masks that are specially designed to fi lter out mi- croscopic particles. Wash hands after handling.

Technical data

Power consumption 350 - 1200 W Connected load to appliance plug socket max 1200 W Total connected load max 2400 W Volume fl ow (air) max., turbine 228 m3/h (8.2 cu.ft./h) Vacuum max., turbine 23000 Pa Filter surface 14000 cm2 (2170 sq.in.) Suction hose, diameter x length 27 mm x 3.5 m (1.06 in. x 11.48 ft.) Dimensions L x W x H:

CT 22 E HEPA 625 x 380 x 440 mm (24.6 x 15 x 17.3 in.) CT 33 E HEPA 625 x 380 x 550 mm (24.6 x 15 x 21.6 in.) Container capacity:

CT 22 E HEPA 22 l (5.7 gal.) CT 33 E HEPA 33 l (8.6 gal.) Weight:

CT 22 E HEPA 12 kg (26.4 lbs) CT 33 E HEPA 14.5 kg (32 lbs) Power cable length 7.5 m (24.6 ft.) Protection type IP X4

The specifi ed illustrations can be found at the beginning of the operating instructions.

The vacuum cleaner is designed in accordance with IEC 60335-1 and IEC 60335-2-69 for a higher loading in industrial use. The fi ltering performance of the overall unit, which is fi tted with a HEPA fi lter element (493334), cor- responds to HEPA quality H 13 (medium degree of fi ltration 99.95 %). All CT extractors fi tted with the HEPA fi lter element (493334) have HEPA certifi cation both for the fi lter material and the whole dust extractor.

Symbols

V volts A amperes Hz hertz W watt ~ alternating current n0 no load speed

The user is liable for damage and injury resulting from incorrect usage!

Intended use

Connections

The vacuum cleaner is designed for use as speci- fi ed for the aspiration and evacuation of non-nox- ious dusts, dirt, sand, shavings etc.. The vacuum cleaner is designed as specifi ed for vacuuming water.

Before start-up: The accessories are delivered in the container (2.10), and must be removed prior to initial operation.

Class II Construction

Page 7 of the Festool CT 33 (CT 33 E HEPA) user manual — Emptying the dirt container
Page 7 · click to enlarge
Page 7

Electrical connection

Equipment

The operating voltage and frequency shown on the specifi cation plate must be the same as the mains power voltage (wall socket).

  • Tools or accessories can be stowed in the storage compartments (1.6, not with CT 22 E HEPA).
  • A systainer can be fi xed on the shelf with the two clamps (1.1).
  • An air blast is obtained by inserting a suction hose in the blast opening (2.7).
  • Stand / Brake: the wheels can be blocked by the brakes (2.8), thus preventing the vacuum cleaner from rolling away unexpectedly.

Make sure that the vacuum cleaner is switched off when you plug the power cable in.

The antistatic system (AS) Friction in the suction hose causes electrostatic charges which can result in unpleasant electric shocks for the operator. In order to conduct these static charges to earth, the extraction units are provided with an antistatic system as a standard feature. However, antistatic hoses and accessories have to be used in this case. The antistatic function will only work if the plug is plugged into a totally earthed socket.

Operation

On/off switch

In position O (1.3) the vacuum cleaner is switched off and the appliance plug socket (1.2) is dead. Two modes of operation are possible:

Temperature control A temperature fuse switches the dust extractor off before this reaches a critical temperature to pro- tect against overheating - switch dust extractor off and leave for around 5 minutes to cool down. If the dust extractor still cannot be switched back on, please consult a Festool-service centre.

a) Switch position „MAN“ The appliance plug socket is dead. The cleaner motor starts immediately.

b) Switch position „Auto“

Before turning the switch to the „Auto“ position, ensure that the tool connected to the appliance plug socket is switched off. The appliance plug socket is live. The cleaner motor starts only when the tool con- nected to the appliance plug socket is switched on.

Connecting the suction hose

Connect the suction hose at the extraction open- ing (1.7).

Connecting an electric tool

Observe the maximum connected load on the ap- pliance plug socket (see “Technical Data“)!

Suction force regulator

The suction force regulator (1.4) can be used to vary the suction capacity. This permits a precise adaptation to different substances to be picked up.

Make sure that the electric tool is switched off when plugging it in and unplugging it. Connect the electric tool to the appliance plug socket (1.2).

Opening/closing the

vacuum cleaner

Connecting pneumatic tools

– Open retaining clamps (2.2) , – Raise upper part (2.4) until support catch (2.5)

Make sure that the pneumatic tool is switched off when plugging it in and unplug- ging it. When the compressed-air module (1.9) (452829) is fi tted, the automatic cut-in of the appliance also operates in conjunction with compressed-air tools. We also recommend fi tting of the VE supply unit (452797). The supply unit fi lters and oils the compressed air and allows the air pressure to be regulated. An IAS connecting piece (454757) is available for connecting Festool compressed-air tools with the IAS system. To ensure trouble-free functioning of the auto- matic cut-in, the operating pressure of the tool must be 6 bar.

engages. Follow the reverse order to close the appliance. You must raise the upper part slightly before de- pressing or disengaging the support.

Emptying the dirt container

Always remove the upper part of the vacuum cleaner before emptying the dirt container (2.10)! – Open the vacuum cleaner, – Raise the upper part slightly, depress the support

(2.5), – Raise the upper part to the stop (vertical posi-

tion),

Page 8 of the Festool CT 33 (CT 33 E HEPA) user manual — Maintenance and care
Page 8 · click to enlarge
Page 8

– Remove the upper part by moving it forwards

– Remove the used fi lter bag (see printed text on

horizontally, – Empty the dirt container, – Replace the upper part. Make sure that both upper-part pins are fully inserted in the recesses (1.5)! – Close the vacuum cleaner.

fi lter bag), – Dispose of the used fi lter bag in accordance with

statutory requirements, – Thoroughly clean the dirt container (2.10) and

the space (3.1) for suction turbine (wipe down with a damp cloth), – Insert new fi lter bag (see printed text on fi lter

Application

bag). Press the fi lter bag sleeve (3.3) fi rmly onto the dust extraction fi tting (3.2)! – Close the vacuum cleaner.

Vacuuming dry materials

Before using the vacuum cleaner to evacuate dry substances, a fi lter bag must always be inserted in the container. Then the evacuated material can be disposed of easily. The fi lter element becomes damp after evacuating liquids. A damp fi lter element suffers more wear and tear if it is used for dry materials. Accordingly, the fi lter element should be dried or replaced with a dry one before dry operation.

Changing the fi lter element (2.3) Order no. (CT 22 E, CT 33 E): Standard fi lter element: 452923 HEPA fi lter element: 493334 Do not operate machine without a fi lter element. This may damage the motor. – Open the vacuum cleaner, – Remove the used fi lter element (see printed text

on the fi lter element packaging), – Dispose of the used fi lter element in a sealed,

Vacuuming liquids

Do not evacuate combustible liq- uids!

dust-tight bag in accordance with statutory re- quirements, – Thoroughly clean dirt container (2.10) and space

If foam or liquid escapes, stop work immediately and empty the dirt container.

(3.1) for the suction turbine (wipe down with a damp cloth), – Fit a new fi lter element (see printed text on the

The HEPA fi lter element shall only be used for extracting dry materials. The fi lter bag has to be removed before evacuat- ing liquids. We recommend use of a special wet fi lter (452924). When the maximum fi lling level is reached, a bag-full indicator (2.12) automatically interrupts extraction.

fi lter element packaging), – Close vacuum cleaner.

Cleaning the fi lter element

To clean, move the handle (2.1) to and fro about 10 times. N.B.: You need to clean the fi lter ele- ment only if you use the vacuum cleaner without a fi lter bag.

Filter

Changing the fi lter

After fi nishing work

During the following procedure, take care not to raise dust more than is unavoidable. Moisten the fi lter element with a water spray be- fore removing it. Check the fi ll level of the fi lter bag at regular intervals. A full fi lter bag shall be replaced im- mediately. Check the fi lter element for damage every time the fi lter bag is changed. Replace damaged fi lter elements immediately. Always insert a fi lter bag when using a HEPA fi lter element.

  • Switch off the cleaner and pull the Plug of the mains lead out of the Plug socket.
  • Wind up the mains lead (2.6).
  • Empty dirt tank.
  • Clean the vacuum cleaner inside and outside by suction and wiping.
  • Deposit the appliance in a dry room, safe from unauthorised use.

Maintenance and care

Always remove the power supply plug from the socket before carrying out any work on the machine.

Changin the fi lter bag (3.4) Order no.: CTL 22 E: 452970 CTL 33 E: 452971 – Open the vacuum cleaner,

All maintenance and repair work which requires the motor casing to be opened may only be carried out by an authorised service centre.

Page 9 of the Festool CT 33 (CT 33 E HEPA) user manual — Festool Limited Warranty
Page 9 · click to enlarge
Page 9

A safety test is to be carried out at least once a year by the manufacturer or an instructed person, e.g. for possible damage to the fi lter and leaks in the appliance, and to ensure that the control devices are functioning.

power tools. No agent, representative, distributor, dealer or employee of Festool has the authority to increase or otherwise change the obligations or limitations of this warranty. The obligations of Festool in its sole discretion under this warranty shall be limited to the repair or replacement of any Festool portable power tool that is found to be defective as packaged with the User Manual. Excluded from coverage under this warranty are: normal wear and tear; damages caused by mis- use, abuse or neglect; damage caused by anything other than defects in material and workmanship. This warranty does not apply to accessory items such as circular saw blades, drill bits, router bits, jigsaw blades, sanding belts, and grinding wheels. Also excluded are “wearing parts”, such as carbon brushes, lamellas of air tools, rubber collars and seals, sanding discs and pads, and batteries. Festool portable power tools requiring replace- ment or repair are to be returned with the receipt of purchase to Festool (call 800-554-8741 for address details). IN NO EVENT SHALL FESTOOL BE LIABLE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY, EXPRESSED OR IMPLIED WHATSOEVER. ALL WARRANTIES IMPLIED BY STATE LAW, INCLUDING THE IMPLIED WARRANTIES OF MERCHANT ABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE HEREBY LIMITED TO THE DURATION OF THREE YEARS. Some states in the U.S. and some Canadian prov- inces do not allow the limitations on how long an implied warranty lasts, so the above limita- tion may not apply to you. With the exception of any warranties implied by state or province law as hereby limited, the foregoing express limited warranty is exclusive and in lieu of all other war- ranties, guarantees, agreements and similar ob- ligations of Festool. This warranty gives you specifi c legal rights and you may also have other rights which vary from state to state in the U.S. and province to province in Canada.

Accessories, fi lter

  • A hose coupling (1.10) (487072) can be plugged into the opening (1.8). The suction hose is connected to the tool from above with the hose coupling. Alternatively, a hose clip (452998) can be fi tted for coiling the suction hose.
  • The push handle (2.11) (452921) makes the vacuum cleaner easier to move. Accessories (e.g. vacuum accessories) can be fi xed to the push handle batten (2.9). The accessory and fi lter order number can be found in your Festool catalogue or on the Internet under <a href="http://www.festool-usa.com" rel="nofollow noopener" target="_blank">www.festool-usa.com</a> .

Warranty

Conditions of 1+2 Warranty

You are entitled to a free extended warranty (1 year + 2 years = 3 years) for your Festool power tool. Festool shall be responsible for all shipping costs during the fi rst year of the warranty. Dur- ing the second and third year of the warranty the customer is responsible for shipping the tool to Festool. Festool will pay for return shipping to the customer using UPS Ground Service. All warranty service is valid 3 years from the date of purchase on your receipt or invoice.

Festool Limited Warranty

This warranty is valid on the pre-condition that the tool is used and operated in compliance with the Festool operating instructions. Festool warrants, only to the original consumer purchaser, that the specifi ed tool will be free from defects in materi- als and workmanship for a term of one year from the date of procurement. Festool makes no other warranty, express or implied, for Festool portable

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Festool CT 33 (CT 33 E HEPA)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Festool CT 33 (CT 33 E HEPA)

Be the first to ask — other owners or our team will answer.

Original document

Festool CT 33 (CT 33 E HEPA) manual PDF

26 pages·316 KB·Vacuum Cleaner·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…