EN
Procom logo
Official user manual

Procom QN300RYLA

25 pages·2.5 MB·Stove·PDF·ENDEFRITNLJA
Procom QN300RYLA
Table of Contents 74 sections COMPACT L.P.& NATURAL · GAS VENT-FREE STOVE · OWNER ’ S OPERATION AND INSTALLATION MANUAL · QN300RYLA QL300RYLA QN300RYLA-W QL300RYLA-W · … ShowHide
COMPACT L.P.& NATURALp.1GAS VENT-FREE STOVEp.1OWNER ’ S OPERATION AND INSTALLATION MANUALp.1QN300RYLA QL300RYLA QN300RYLA-W QL300RYLA-Wp.1Continental Appliance Inc./U.S. Officep.1TOLL-FREE NUMBER: 1-877-886-5989p.1Table of Contentsp.2Safety information warnings--------------------3p.2Air for conbustion & Ventilation----------------5p.2Installation-------------------------------------------7p.2Operation Heater---------------------------- -----11p.2Cleaning and Maintenance-------------------- 13p.2Specification----------------------------------------15p.2Troubleshooting---------------------------------- 16p.2Parts Breakdown & Parts List-----------------18p.2Log Placing Instructions------------------------22p.2SAFETY INFORMATION WARNINGSp.3LOCAL CODESp.4PRODUCT FEATURES SAFETY PILOTp.4Remote control SYSTEMp.4PRODUCT IDENTIFICATIONp.4AIR FOR COMBUSTION AND VENTILATIONp.5PROVIDING ADEQUATE VENTILATIONp.5INSTALLATIONp.7CHECK GAS TYPEp.7CONNECTING TO GAS SUPPLYp.8Pressure Testing Gas Supply Piping Systemp.9CHECKING GAS CONNECTIONSp.9OPERATING HEATERp.11FOR YOUR SAFETYp.11OPERATING INSTRUTION OFp.11READ BEFORE LIGHTINGp.11REMOTE-CONTROLLED BUNERp.11LIGHTING INSTRUCTIONSp.11OPERATINGp.12HEATERp.12Continuedp.12b. manual select of mainp.12burner:p.12 OPERATIONS OF p.12c.shut off the main burner:p.12 OPERATIONS OF REMOTE TRANSMITTERp.12TIMING 1 .Auto on:p.12TURN-OFFp.12 OPERATIONS OF KEY-PRESS LOCKINGp.13BURNER FLAME PATTERNp.13FANp.13INSPECTING BURNERSp.13CLEANING AND MAINTENANCEp.13DISCONNECT WIRNG OR CONTROL MODULEp.13CABINETp.14PARTS UNDER WARRANTYp.14NG)p.14FLEXILBE HOSEp.15SPECIFICATIONSp.15TROUBLESHOOTINGp.16OBSERVED PROBLEM POSSIBLE CAUSEp.16REMEDYp.16OBSERVED PROBLEM POSSIBLE CAUSE REMEDYp.17ILLUSTRATED PARTS BREAKDOWN QL300RYLA QN300RYLA QL300RYLA-W QN300RYLA-Wp.18PARTS LIST QL300RYLA QN300RYLA QL300RYLA-W QN300RYLA-Wp.19PLACING INSTRUCTIONp.22THEN REMOVE SCREEN AND TAKE OUT THE LOG’S PACKAGEp.22THE LOG’S PACKAGE IS LOCATED INSIDE THE UNITp.22FIRST REMOVE TWO TOP SCREWS FROM SCREENp.22BOTTOM PANELp.22Q SERIES LOG SETp.23INSTALLATION INSTRUCTIONSp.23INSTALLATION INSTRUCTIONS FOR LOG SETSp.241. All logsp.24FIG(1) FIG(2)p.24FIG(3) FIG(4)p.24FIG(5)p.25FIG(6)p.25
Page 1 of the Procom QN300RYLA user manual — TOLL-FREE NUMBER: 1-877-886-5989
Page 1 · click to enlarge
Page 1
Procom QN300RYLA — COMPACT L.P.& NATURAL diagram (page 1)
Fig. 1

COMPACT L.P.& NATURAL

GAS VENT-FREE STOVE

OWNER ’ S OPERATION AND INSTALLATION MANUAL

QN300RYLA QL300RYLA QN300RYLA-W QL300RYLA-W

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance. Do not touch any electrical switch; do not use any phone in your building. Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. If you cannot reach your gas supplier, call the fire department. Installation and service must be performed by a qualified installer, service agency, or local gas supplier.

This appliance may be installed in an aftermarket*, permanently located manufactured (mobile) home, where not prohibited by local codes.This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

Continental Appliance Inc./U.S. Office

5 Musick 4600 Highlands Parkway S.E. Irvine Suite# D/E CA 92618 Smyrna GA 30080

WATER VAPOR:A BY-PRODUCT OF UNVENTED ROOM HEATERS Water vaporis a by-product of gas combustion.An unvented room heater produces approximately one (1)ounce (30)ml of water for every 1,000BTU’S (.3KW’S) OF gas input per hour,Refer to papg 7.

Nanjing PRO-COM Electric Appliance Co.,Ltd. #6 Chuangye Road,High New Tech.Zone, Great Bridge Road North,Nanjing,210061,China.

Procom QN300RYLA — Continental Appliance Inc./U.S. Office diagram (page 1)
Fig. 2 · Continental Appliance Inc./U.S. Office

Consumer : please retain these instruction for future use.

Installer:Please leave these instructions with the consumer.

*Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer.

TOLL-FREE NUMBER: 1-877-886-5989

Page 2 of the Procom QN300RYLA user manual — Table of Contents
Page 2 · Contents
Contents

Contents

COMPACT L.P.& NATURALp.1GAS VENT-FREE STOVEp.1OWNER ’ S OPERATION AND INSTALLATION MANUALp.1QN300RYLA QL300RYLA QN300RYLA-W QL300RYLA-Wp.1Continental Appliance Inc./U.S. Officep.1TOLL-FREE NUMBER: 1-877-886-5989p.1Table of Contentsp.2Safety information warnings--------------------3p.2Air for conbustion & Ventilation----------------5p.2Installation-------------------------------------------7p.2Operation Heater---------------------------- -----11p.2Cleaning and Maintenance-------------------- 13p.2Specification----------------------------------------15p.2Troubleshooting---------------------------------- 16p.2Parts Breakdown & Parts List-----------------18p.2Log Placing Instructions------------------------22p.2SAFETY INFORMATION WARNINGSp.3LOCAL CODESp.4PRODUCT FEATURES SAFETY PILOTp.4Remote control SYSTEMp.4PRODUCT IDENTIFICATIONp.4AIR FOR COMBUSTION AND VENTILATIONp.5PROVIDING ADEQUATE VENTILATIONp.5INSTALLATIONp.7CHECK GAS TYPEp.7CONNECTING TO GAS SUPPLYp.8Pressure Testing Gas Supply Piping Systemp.9CHECKING GAS CONNECTIONSp.9OPERATING HEATERp.11FOR YOUR SAFETYp.11OPERATING INSTRUTION OFp.11READ BEFORE LIGHTINGp.11REMOTE-CONTROLLED BUNERp.11LIGHTING INSTRUCTIONSp.11OPERATINGp.12HEATERp.12Continuedp.12b. manual select of mainp.12burner:p.12 OPERATIONS OF p.12c.shut off the main burner:p.12 OPERATIONS OF REMOTE TRANSMITTERp.12TIMING 1 .Auto on:p.12TURN-OFFp.12 OPERATIONS OF KEY-PRESS LOCKINGp.13BURNER FLAME PATTERNp.13FANp.13INSPECTING BURNERSp.13CLEANING AND MAINTENANCEp.13DISCONNECT WIRNG OR CONTROL MODULEp.13CABINETp.14PARTS UNDER WARRANTYp.14NG)p.14FLEXILBE HOSEp.15SPECIFICATIONSp.15TROUBLESHOOTINGp.16OBSERVED PROBLEM POSSIBLE CAUSEp.16REMEDYp.16OBSERVED PROBLEM POSSIBLE CAUSE REMEDYp.17ILLUSTRATED PARTS BREAKDOWN QL300RYLA QN300RYLA QL300RYLA-W QN300RYLA-Wp.18PARTS LIST QL300RYLA QN300RYLA QL300RYLA-W QN300RYLA-Wp.19PLACING INSTRUCTIONp.22THEN REMOVE SCREEN AND TAKE OUT THE LOG’S PACKAGEp.22THE LOG’S PACKAGE IS LOCATED INSIDE THE UNITp.22FIRST REMOVE TWO TOP SCREWS FROM SCREENp.22BOTTOM PANELp.22Q SERIES LOG SETp.23INSTALLATION INSTRUCTIONSp.23INSTALLATION INSTRUCTIONS FOR LOG SETSp.241. All logsp.24FIG(1) FIG(2)p.24FIG(3) FIG(4)p.24FIG(5)p.25FIG(6)p.25
Page 3 of the Procom QN300RYLA user manual — SAFETY INFORMATION WARNINGS
Page 3 · click to enlarge
Page 3

SAFETY INFORMATION WARNINGS

I M P O R TA N T: R e a d t h i s owner’s manual carefully and completely before trying to assemble, operate, or service this heater. Improper use of this heater can cause serious injury or death from burns, fire, explosion, electrical shock, and carbon monoxide poisoning.

1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases. 2. Do not place Propane/LP supply tank(s) inside any structure. Locate Propane/LP supply tank(s) outdoors. 3. If you smell gas Shut off gas supply. Do not try to light any appliance. Do not touch any electrical switch: do not use any phone in your building. Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. If you cannot reach your gas supplier, call the fire department.

Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.

Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, or nausea. If you have these signs, the heater may not be working properly. Get fresh air at once! Have heater serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease, anemia, those under the influence of alcohol, and those at high altitudes.

Do not place clothing or other flammable material on or near the appliance. Never place any objects in the fireplace.

4. This heater shall not be installed in a bedroom or bathroom. 5. Do not use this heater as a wood-burning heater. Use only the logs provided with the heater. 6. Do not add extra logs or ornaments such as pine cones, vermiculite, or

Heater becomes very hot when running fireplace. Keep children and adults away from hot surfaces to avoid burns or clothing ignition. Fireplace will remain hot for a time after shutoff. Allow surfaces to cool before touching.

rock wool.Using these added items can cause sooting. Do not add lava rock around base. Rock and debris could fall into the control area of heater. After servicing, always replace screen before operating heater. 7. You must operate this heater with the heater screen in place. Make sure heater screen is in place before running heater. 8. This heater is designed to be smokeless. If logs ever appear to smoke, turn heater off and call a qualified service person. Note: During initial operation, slight smoking could occur due to log c u r i n g a n d h e a t e r b u r n i n g manufacturing residues. 9. To prevent the creation of soot, follow the instructions in Cleaning and Maintenance

Propane/LP Gas: Propane/LP gas is odorless. An odor-making agent is added to Propane/LP gas. The o d o r h e l p s y o u d e t e c t a Propane/LP gas leak. However, the odor added to Propane/LP gas can fade. Propane/LP gas may be present even though no odor exists. Natural Gas: Natural gas is odorless. An odormaking agent is added to natural gas. The odor helps you detect a natural gas leak. However, the odor added to natural gas can fade. Natural gas may be present even though no odor exists. Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this heater.

Carefully supervise young children when they are in the room with the fireplace.

You must operate this heater with the heater screen in place. Make sure the heater screen is in place before running heater.

Keep the appliance area clear and free from combustible materials, gasoline, and other flammable vapors and liquids.

Page 4 of the Procom QN300RYLA user manual — PRODUCT IDENTIFICATION
Page 4 · click to enlarge
Page 4

SAFETY INFORMATION Continued 15. Turn off and unplug heater and let cool before servicing. Only a

LOCAL CODES

. 10. Before using furniture polish, wax, carpet cleaner, or similar products, turn heater off. If heated, the vapors from these products may create a white powder residue within burner box or on adjacent walls or furniture. 11. This heater needs fresh air ventilation to run properly. This heater has an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS shuts down the heater if not enough fresh air is available. See Air for Combustion and Ventilation, pages 5through 6. If heater keeps shutting off, see Troubleshooting, pages 16 through 17. 12. Do not run heater: Where flammable liquids or vapors

lnstall and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code, ANSZ 223.1, also known as NFPA 54*. *Available from: American National Standards lnstitute, lnc. 1430 Broadway

qualified service person should service and repair heater. 16. Operating heater above elevations of 4,500 feet could cause pilot outage. 17. Do not operate heater if any log is broken. Do not operate heater if a log is chipped (dime-sized or larger). 18. To prevent performance problems, do not use Propane/LP fuel tank of less than 100 lbs. capacity.

New York, NY 10018 National Fire Protection Association, lnc.

Batterymarch Park Quincy. MA 02269 This heater is designed for vent-free operation. State and local codes in some areas prohibit the use of vent-free heaters.

PRODUCT FEATURES SAFETY PILOT

This heater has a pilot with an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS/pilot is a required feature for vent-free room heaters. The ODS/pilot shuts off the heater if there is not enough fresh air.

are used or stored. Under dusty conditions. 13.Do not use this heater to cook food or burn paper or other objects.

UNPACKING 1. Remove top inner pack. 2. Tilt carton so that stove is upright. 3. Remove protective side packaging. 4. Slide stove out of carton. 5. Remove protective plastic wrap. 6. Remove two self-tapping screws on the screw , then lift and

14. Do not use heater if any part has been under water. lmmediately call a qualified service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water.

Remote control SYSTEM

This fireplace has a remote transimit- ter.This system requires three batteries, and provides electric power outlet to operate.

pulling forward. 7. Remove log set by cutting plastic ties. 8. Carefully unwrap log. 9. Check for any shipping damage. If stove or log is damaged, promptly inform dealer where you bought stove.

PRODUCT IDENTIFICATION

Figure1- Vent Free LP/NG Gas Stove

Show 4 more labels / short text on this page
Stove Cabinet · Screen · Log · Heater Control
Page 5 of the Procom QN300RYLA user manual — PROVIDING ADEQUATE VENTILATION
Page 5 · click to enlarge
Page 5

AIR FOR COMBUSTION AND VENTILATION

Confined and Unconfined Space

The National Fuel Gas Code, ANS Z223.1 defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space and an unconfining space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space. Rooms communicating directly with the space in which the appliances are installed*, through openings not furnished with doors, are considered a part of the unconfined space.

The air that leaks around doors and windows may provide enough fresh air for combustion and ventilation. However, in buildings of unusually tight construction, you must provide additional fresh air. Unusually tight construction is defined as construction where: a) walls and ceilings exposed to the

home.

outside atmosphere have a continuous water vapor retarder with a rating of one perm (6×10-11kg per pa-sec-m 2) or less with openings gasketed or sealed and b) weather stripping has been added

PROVIDING ADEQUATE VENTILATION

The following are excerpts from National Fuel Gas Code, NFPA 54/ ANSZ 223.1,Section 5.3, Air for Combustion and Ventilation. All spaces in homes fall into one of the three following ventilation classifications: 1. Unusually Tight Construction 2. Unconfined Space 3. Confined Space The information on pages 5 through 6 will help you classify your space and provide adequate ventilation.

on openable windows and doors and c) caulking or sealants are applied to

This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air.

areas such as joints around window and door frames, between sole plates and floors, between wall-ceiling joints, between wall panels, at penetrations for plumbing, electrical, and gas lines, and at other openings. If your home meets all of the three criteria above, you must provide additional fresh air. See Ventilation Air From Outdoors. If your home does not meet all of the three criteria above, proceed to Determining Fresh-Air Flow For Heater Location.

* Adjoining rooms are communicating only if there are doorless passage- ways or ventilation grills between them.

DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION Determining if You Have a Confined or Unconfined Space Use this worksheet to determine if you have a confined or unconfined space. Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms. 1. Determine the volume of the space (length×width×height). Length×Width×Height= cu.ft. (volume of space) Example: Space size 20ft. (length)×16ft.(width)×8ft. (ceiling height)=2560cu. ft. (volume of space) If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these rooms to the total volume of the space. 2. Divide the space volume by 50 cubic feet to determine the maximum Btu/Hr the space can support.

(volume of space)÷50 cu. ft.=(Maximum Btu/Hr the space can support)

Example: 2560 cu. ft. (volume of space)÷50 cu.ft.=51.2 or 51,200(maximum Btu/Hr the space can support)

Unusually Tight Construction

Page 6 of the Procom QN300RYLA user manual — AIR FOR COMBUSTION AND VENTILATION
Page 6 · click to enlarge
Page 6

3. Add the Btu/Hr of all fuel burning appliances in the space. Vent-free heater Btu/Hr Gas water heater* Btu/Hr Gas furnace Btu/Hr Vented gas heater Btu/Hr Gas heater logs Btu/Hr Other gas appliances* + Btu/Hr Total = Btu/Hr *Do not include direct-vent gas appliances. Direct-vent draws combustion air from the outdoors and vents to the outdoors. 4. Compare the maximum Btu/Hr the space can support with the actual amount of Btu/Hr used. Btu/Hr (maximum the space can support) Btu/Hr (actual amount of Btu/Hr used) Example: 51,200 Btu/Hr(maximum the space can support) 56,000 Btu/Hr(actual amount of Btu/Hr used) The space in the above example is a confined space because the actual Btu/Hr used is more than the maximum Btu/Hr the space can support. You must provide additional fresh air. Your options are as follows: A. Rework worksheet, adding the space of an adjoining room. If the extra space provides an unconfined space, remove door to adjoining room or add ventilation grills between rooms. See Ventilation Air From Inside Building. B. Vent room directly to the outdoors. See Ventilation Air From Outdoors. C. Install a lower Btu/Hr heater, if lower Btu/Hr size makes room unconfined.

ExampleGas water heater 30,000 Btu/Hr Vent-free heater + 26,000 Btu/Hr Total = 56,000 Btu/Hr

If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support, the space is an unconfined space. You will need no additional fresh air ventilation.

Ventilation Air From lnside Building

This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 2). You can also remove door into adjoining room (see option 3, Figure 2). Follow the National Fuel Gas Code. NFPA 54/ANS Z223.1, Sec- tion 5.3, Air for Combustion and Ventilation for re- quired size of ventilation grills or ducts.

Procom QN300RYLA — AIR FOR COMBUSTION AND VENTILATION diagram (page 6)
Fig. 3

Ventilation Air From Outdoors

Provide extra fresh air by using ventilation grills or ducts. You must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces. Follow the National Fuel Gas Code, NFPA 54/ANS Z223.1, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts. IMPORTANT: Do not provide openings for inlet or outlet air into attic if attic has a thermostat-controlled power vent. Heated air entering the attic will activate the power vent.

Figure 2 -Ventilation Air from Inside Building

Procom QN300RYLA — AIR FOR COMBUSTION AND VENTILATION diagram (page 6)
Fig. 4

Figure 3 -Ventilation Air from Outdoors

outlet

Page 7 of the Procom QN300RYLA user manual — CHECK GAS TYPE
Page 7 · click to enlarge
Page 7

INSTALLATION

WATER VAPOR:A BY-PRODUCT OF UNVENTED ROOM HEATERS Water vapor is by-product of gas combustion.an unvented room heater prodrces approximately one (1) ounce (30ml) of water for every 1, 000BTU’s (.3kw’s) of gas input per hour. Unvented room heaters are recom- mended as supplemtal heat (a room) rather that a primary heat source(an entire house) in most supplemental heat applications,the water vapor does not create a problem ,in most applications the water vapor enhances the low humidity atmosphers experienced during cold weather. The following steps will help insure that water vapor does not become a problem. 1. Besure the heater is sized prop- erly for the application,including ample combustion air and circula- tion of the air. 2.If high humidity is experienced, a dehumidifier may be used to help lower the water vapor content of the air. 3.Do not use an unvented room heater as the primary heat source.

Procom QN300RYLA — INSTALLATION diagram (page 7)
Fig. 5
Procom QN300RYLA — INSTALLATION diagram (page 7)
Fig. 6

Figure 4 -Minimum Clearance to Wall and Ceiling

CHECK GAS TYPE

Be sure your gas supply is right for your heater. Otherwise, call dealer where you bought the heater for proper type heater.

IMPORTANT: Vent-free heaters add moisture to the air. Although this is beneficial, installing heater in rooms without enough ventilation air may cause mildew to form from too much moisture. See Air for Combustion and Ventilation, pages 5 through 6.

Page 8 of the Procom QN300RYLA user manual — CONNECTING TO GAS SUPPLY
Page 8 · click to enlarge
Page 8

CLEARANCES TO COMBUSTIBLES (Vent-Free Operation Only) Carefully follow the instructions below. This stove is a freestanding unit designed to set directly on the floor.

The installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to rating inches of water. If you do not reduce incoming gas pressure, heater regulator damage could occur. lnstall external regulator with the vent pointing down as shown in Figure 6. Pointing the vent down protects it from freezing rain or sleet.

Procom QN300RYLA — CONNECTING TO GAS SUPPLY diagram (page 8)
Fig. 7

Minimum Wall and Ceiling Clearances (see Figure 4) A. Clearances from outermost point

of stove top to any combustible side wall should not be less than 24 inches. B. Clearances from outermost point of

stove top to any combustible back wall should not be less than 10 i n c h e s ( l n c l u d e s c o r n e r installations). C. Clearances from the stove top to

Figure 5 -Gas Regulator Location and Gas Line Access Into Stove Cabinet

the ceiling should not be less than 48 inches.

Procom QN300RYLA — CONNECTING TO GAS SUPPLY diagram (page 8)
Fig. 8

CONNECTING TO GAS SUPPLY

Figure 6 -External Regulator With Vent Pointing Down

NG Models: 5”-10.5” W.C. Gas supplier provides external regulator for natural gas.

INSTALLATION ITEMS NEEDED Before installing heater, make sure you have the items listed below. piping (check local codes) sealant (resistant to propane/LP gas) equipment shutoff valve* test gauge connection* sediment trap tee joint pipe wrench flexible gas hose.(check local codes) *A CSA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional CSA design-certified equipment shutoff valve from your dealer. See Accessories.

Procom QN300RYLA — CONNECTING TO GAS SUPPLY diagram (page 8)
Fig. 9

Figure 7 -Gas Connection

* Purchase the optional CSA design-certified equipment shutoff valve from your dealer. See Accessories. ** Minimum inlet pressure for purpose of input adjustment.

Propane/LP Supply Tank · purchase

Page 9 of the Procom QN300RYLA user manual — CHECKING GAS CONNECTIONS
Page 9 · click to enlarge
Page 9

Pressure Testing Gas Supply Piping System

Test Pressures In Excess Of 1/2 PSIG(3.5kPa) 1. Disconnect heater with its appliance main gas valve (control valve) and equipment shutoff valve from gas supply piping system. Pressures in excess of 1/2 PSIG will damage heater regulator. 2. Cap off open end of gas pipe where equipment shutoff valve was connected. 3. Pressurize supply piping system by either using compressed air or opening gas supply tank valve. 4. Check all joints of gas supply piping system. Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak. 5. Correct all leaks at once. 6. Reconnect heater and equipment shutoff valve to gas supply. Check reconnected fittings for leaks.

CHECKING GAS CONNECTIONS

codes. Use pipe of 1/2" diameter or greater to allow proper volume gas to heater. If pipe is too small, undue loss of pressure will occur.

Installation must include an equip- ment shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 7).

Procom QN300RYLA — CHECKING GAS CONNECTIONS diagram (page 9)
Fig. 10

Pressure Testing Heater Gas Connections 1. Open equipment shutoff valve (see Figure 8).

Figure 8 -Equipment Shutoff Valve

We recommend that you install a sediment trap in supply line as shown in Figure 7. Locate sediment trap where it is within reach for cleaning. Install in piping system between fuel supply and heater. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into heater controls. If sediment trap is not installed or is installed incorrectly, heater may not run properly.

Figure 9.1 -Checking Gas Joints

Extemal Regulotor · Propane/LP Supply Tank · Equipm ent Shut

Page 10 of the Procom QN300RYLA user manual — Pressure Testing Gas Supply Piping System
Page 10 · click to enlarge
Page 10

2. Open gas supply tank valve. 3. Make sure control knob of heater is in the OFF position. 4. Check all joints from equipment shutoff valve to control valve (LP GAS see Figure 9.1 NATURAL GAS see Figure 9.2). Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak. 5. Correct all leaks at once. 6. Light heater (see Operating Heater). Check all other internal joints for leaks. 7. Turn off heater (see To Turn Off Gas Appliance).

It is very important to install the logs exactly as instructed. Do not modify logs. Only use logs supplied with heater.

Place log set on grate to fit as illustrated in Figure 10. Make sure log sits flat on firebox floor (see Figure 10).

Also, see log placing instructions.

Procom QN300RYLA — Pressure Testing Gas Supply Piping System diagram (page 10)
Fig. 11 · Pressure Testing Gas Supply Piping System

Test Pressures Equal To or Less Than 1/2 PSIG(3.5 kPa) 1. Close equipment shutoff valve (see Figure 8). 2. Pressurize supply piping system by either using compressed air or opening natural supply tank valve. 3. Check all joints from gas meter to equipment shutoff valve(see Figure 9). Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak. 4. Correct all leaks at once.

Figure 10 -Installing Log Set

Procom QN300RYLA — Pressure Testing Gas Supply Piping System diagram (page 10)
Fig. 12 · Pressure Testing Gas Supply Piping System
Procom QN300RYLA — Pressure Testing Gas Supply Piping System diagram (page 10)
Fig. 13 · Pressure Testing Gas Supply Piping System

Figure 11 -Installing Log Set (Top View) Figure 9.2 -Checking Gas Joints

Page 11 of the Procom QN300RYLA user manual — LIGHTING INSTRUCTIONS
Page 11 · click to enlarge
Page 11

OPERATING HEATER

FOR YOUR SAFETY

OPERATING INSTRUTION OF

READ BEFORE LIGHTING

REMOTE-CONTROLLED BUNER

LIGHTING INSTRUCTIONS

1. STOP! Read the safety information, page 2. 2. Make sure equipment shutoff valve is fully open. Figure 12-1 Emergency Button location

A. This appliance has a pilot which

must be lighted by control system, When lighting the pilot, follow these instructions exactly.

B. BEFORE LIGHTING smell all

If you didn’t receive or mis-place your remote transimitter,you can press the emergency button by a pitch rod to operate remote automatically on or off (see fig 12-2)

around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. WHAT TO DO IF YOU SMELL GAS SEE WARNING in Page 1 for proper instructiors.

Procom QN300RYLA — LIGHTING INSTRUCTIONS diagram (page 11)
Fig. 14

C. Use only your hand to push in control knob. Never use tools. If the the appli ance could not operate , don't try to repair it, Call a qualified service technician or gas supplier.Forced or at- tempted re-pair may result in a fire or explosion. D. Do not use this appliance if any part has been under water. Imme- diately call a qualified service techni- cian to inspect the appliance and to replace any part of the control system and any gas control which has been under water. TO TURN OFF GAS TO APPLIANCE Shut off heater 1. Press the IGN/OFF button of transmitter. 2.Set the Switch on OFF location.(See Figure12-2) Shutting off burner only( pilot stay lit) 1.press the BURNER to set flame OFF select

Procom QN300RYLA — LIGHTING INSTRUCTIONS diagram (page 11)
Fig. 15

Figure 12-2 On/Off Switch

Fig 13 Front of the Transmitter

Page 12 of the Procom QN300RYLA user manual —  OPERATIONS OF
Page 12 · click to enlarge
Page 12

OPERATING

(Note: on the auto select of main burner, the main burner does not respond imm-ediately to the set tempera- ture until about one minute later.)

Procom QN300RYLA — OPERATING diagram (page 12)
Fig. 16

HEATER

Continued

Procom QN300RYLA — Continued diagram (page 12)
Fig. 17 · Continued

b. manual select of main

burner:

Press BURNER button, the flame is on “MAN” select. At this selection, the main burner will keep working no matter what the temperature is set at. If there is a need to shut off the main burner, just press the “BURNER” button to make the

OPERATIONS OF

BURNER 1.Plug-in 110V electrical outlet, you will hear a high pitch sound and power light (red) on the front will be lit that indicates that the burner is ready to be operated. Before plugging in the outlet make sure that the appliance is connected to the gas supply, then continue to the next step. 2.Point directly the remote transmitter to the burner. Press IGN/OFF button, the electric spark starts igniting the pilot and operation light (green) on the front will be lit. Wait five (5) minutes to clear out any air. If you smell gas. STOP! Please check the gas connection. There are three selections: “AUTO” “MAN” and “OFF” a.auto select of main burner: Press BURNER button, the flame is

burner on the “OFF” select.

c.shut off the main burner:

the main burner is on “OFF” selection,. The main burner will shut off.

Fig 14 Back of the Transmitter

OPERATIONS OF

OPERATIONS OF REMOTE TRANSMITTER

TIMING 1 .Auto on:

1.Install three AAA SIZE batteries in the bat- tery holder. The initial start-up on the LCD is: SET TEMP is 77°F, ROOM TEMP is 77°F, clock is AM12: 00, burner is on “OFF” select, and fan is on “AUTO” select. Divide Points of hour and minute are flashing (i.e. the timer is operating).

when the burner is in a state of readiness. Transmitter and burner is off. Press TIMER button. Then press ¡ø or¨‹ change to the scheduled time, then press the TIMER button again, the TIMER starts timing and the TIMER is flashing and the operation light(green) begin flashing. When the timer goes on the scheduled time, the burner opens automatically.

on “AUTO” select. Press¡ø or¨‹to set temperature. If the room temperature is two degree lower than the set temperature on the remote, the main burner will turn on until the surrouding temperature is two degree higher than the set temperature. Once it reaches temperature on the remoter, the main burner will automatically shut off.

Procom QN300RYLA —  OPERATIONS OF  diagram (page 12)
Fig. 18

2.Auto off:

when the burner is in operation, press TIMER button. Then press ¡ø or¨‹ to change to the scheduled time, then press the TIMER button again, the TIMER starts timing and the TIMER is flashing and the operation light begin flashing. When the timer goes on the scheduled time, the burner closes automatically.(See Fig 14)

Procom QN300RYLA —  OPERATIONS OF  diagram (page 12)
Fig. 19

Fig 25 Initial start-up on the LCD

2.Clock setting: Press CLOCK button on the remote transmitter panel to select item (hour, minute). The selected item is flashing. Press ¡ø oooorrrr¨‹to change to the correct actual hour (s); Press ¡ø oooorrrr¨‹ ttttoooo change to the cor- rect minute(s), then press CLOCK button again, time setting is finished.

OPERATIONS OF

TURN-OFF

1.Manual turn-off: when the heater is in operation, press the IGN/OFF button to shut off the heater.

3. When in operation, point the remote transmitter to the remote receiver on the burner in a maximum distance of 20 feet without any obstruction between them.
2.Auto turn-offrefer to the second step of “Operations of Timing”

Fig16 Control board · Fig17 “AUTO” select

Page 13 of the Procom QN300RYLA user manual — DISCONNECT WIRNG OR CONTROL MODULE
Page 13 · click to enlarge
Page 13

3.After completion of the above- mentioned two steps, the transmitter is kept in a state of readiness. If the appliance doesn’t working for a period time, just pull out the plug from the 110V electrical outlet.

Procom QN300RYLA —  OPERATIONS OF  KEY-PRESS LOCKING diagram (page 13)
Fig. 20

sensing bulb from the clip, then disco-

nnect the wires to free to control module from its mounting location .

2. Remove two screws and hex nuts,

OPERATIONS OF KEY-PRESS LOCKING

Figure 19 -Incorrect Pilot Flame Pattern

take out the control module. When in- stalling , reverse the steps above.

1.Key press locking: when the burner is in operation or the transmitter is in a state of readiness, just press LOCK button on the operating panel, there will be a “ ” symbol on the LCD. If any button is pressed now, the burner will not react at all. 2.Key-press unlocking: when the burner is in a state of key- press locking, first press ¨‹ , then press LOCK button to unlock it (Child proof-See Fig17)

BURNER FLAME PATTERN

(See Figure 22 and Figure 26)

Figure 20 shows a correct burner flame pattern. Figure 21 shows an incorrect burner flame pattern. If burner flame is incorrect: Turn heater off (see TO TURN OFF GAS TO APPLIANCE) See troubleshooting

Procom QN300RYLA — BURNER FLAME PATTERN diagram (page 13)
Fig. 21
Procom QN300RYLA — BURNER FLAME PATTERN diagram (page 13)
Fig. 22

Figure 22- Control Model DISCONNECT FAN 1. Remove screws from the fan

bracket panel , pull the fan bracket panel out to remove. Then disconne-

OPERATIONS OF

ct two wires free to fan. 2. Mark or tag each wire removed

FAN

There are three selections: “AUTO” “MAN” and “OFF”.When pushing the “FAN” button on the “AUTO” select, the fan will be controlled by the thermostat on the fan blower unit. On the “MAN” select, the fan will be kept in operation.To stop the operation, push the “FAN”button to “OFF”select. (See Fig17)

Figure 20-Correct Flame Pattern with Control Knob Set to High Flame

for its exact reconnection. Remove the four screws from the fan .when

installing , reverse the steps above. (See Figure 23 and Figure 26)

Procom QN300RYLA — FAN diagram (page 13)
Fig. 23
Procom QN300RYLA — FAN diagram (page 13)
Fig. 24

INSPECTING BURNERS

Check pilot flame pattern and burner flame patterns often.

Figure 21 -Incorrect Flame Pattern with Control Knob Set to High Flame

CLEANING BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLE

PILOT FLAME PATTERN Figure 18 shows a correct pilot flame pattern. Figure 19 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple.This will cause the thermocouple to cool. When the thermocouple cools, the heater will shut down. If pilot flame pattern is incorrect, as shown in Figure 19. Turn heater off (see TO TURN OFF GAS TO APPLIANCE) see troubleshooting

CLEANING AND MAINTENANCE

CAUTION: You must keep c o n t r o l a r e a s , b u r n e r , a n d circulating air passageways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a qualified service person. H e a t e r m a y n e e d m o r e f r e q u e n t c l e a n i n g d u e t o excessive lint from carpeting, bedding material, pet hair, etc.

fore attempting any maintenance or cleaning to reduce the risk of fire , elec- tric shook or personal injury. Turn off heater and let cool before cleaning.

The primary air inlet holes allow the proper amount of air to mix with the gas. This provides a clean burning flame. Keep these holes clear of dust, dirt, lint, and pet hair. Clean these air inlet holes prior to each heating season. Blocked air holes will create soot. We recommend that you clean the unit every three months during operation and have heater inspected yearly by a qualified service person.

when servicing controls.

Wiring errors can cause improper and dangerous operation.

Procom QN300RYLA — CLEANING AND MAINTENANCE diagram (page 13)
Fig. 25

Verify proper operation after servicing.

DISCONNECT WIRNG OR CONTROL MODULE

1. Remove screws from the rear control panel , take out thermostat

Figure 18 -Correct Pilot Flame Pattern

Figure 23- Fan

Page 14 of the Procom QN300RYLA user manual — NG)
Page 14 · click to enlarge
Page 14

We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt. To clean these parts we recommend using compressed air no greater than 30 PSI. Your local computer store, hardware store, or home center may carry compressed air in a can. You can use a vacuum cleaner in the blow position. If using compressed air in a can, please follow the directions on the can. If you don't follow directions on the can, you could damage the pilot assembly.

CABINET

Procom QN300RYLA — CABINET diagram (page 14)
Fig. 26

Air Passageways Use a vacuum cleaner or

pressurized air to clean. Exterior Use a soft cloth dampened with a

mild soap and water mixture. Wipe the cabinet to remove dust. LOGS If you remove logs for cleaning,

refer to Installing Logs to properly replace logs. Replace logs if broken or chipped

Figure 25-Pilot Inlet Air Hole

(dimesized or larger).

1. Shut off the unit, including the pilot. Allow the unit to cool for at least thirty minutes. 2. Inspect burner, pilot and primary air inlet holes on injector holder for dust and dirt (See Figure 24). 3 . B l o w a i r t h r o u g h t h e ports/slots and holes in the burner. 4. Check the injector holder located at the end of the burner tube again. Remove any large particles of dust, dirt, lint, or pet hair with a soft cloth or vacuum cleaner nozzle. 5. Blow air into the primary air holes on the injector holder. 6. In case any large clumps of dust have now been pushed into the burner repeat steps 3 and 4. Clean the pilot assembly also. A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly. There is a small pilot air inlet hole about two inches from where the pilot flame comes out of the pilot assembly (see Figure 25). With the unit off, lightly blow air through the air inlet hole. You may blow through a drinking straw if compressed air is not available.

MAIN BURNER Periodically inspect all burner flame holes with the heater running. All slotted burner flame holes should be open with yellow flame present. All round burner flame holes should be o p e n w i t h a s m a l l b l u e f l a m e present. Some burner flame holes may become blocked by debris or rust, with no flame present. If so, turn off heater and let cool. Either remove blockage or replace burner. Blocked burner flame holes will create soot.

REPLACEMENT PARTS NOTE: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.

PARTS UNDER WARRANTY

Contact authorized dealers of this product. If they can't supply original replacement part(s) call the number on the back of manual. when contacting your dealer or PRO-COM, have ready: Your name Your address Model and serial numbers of your heater How heater was malfunctioning Type of gas used (propane/LP or

NG)

Procom QN300RYLA — NG) diagram (page 14)
Fig. 27
Procom QN300RYLA — NG) diagram (page 14)
Fig. 28

Figure 24 -Injector Holder on Outlet Burner Tube

Burner · Figure 26-

Page 15 of the Procom QN300RYLA user manual — SPECIFICATIONS
Page 15 · click to enlarge
Page 15

ACCESSORIES Purchase these heater accessories

Purchase date Usually, we will ask you to return the defective part to the factory. Warranty card.

FLEXILBE HOSE

from your local dealer or Parts Central. This part is not currently available from PRO-COM.

Flexibe gas hose is used for connect- ing the heater to gas supply.

the flex hose must approved by CSA .

Procom QN300RYLA — FLEXILBE HOSE diagram (page 15)
Fig. 29

PARTS NOT UNDER WARRANTY Contact authorized dealers of this product or Parts Central. If they can’t supply original replacement part(s) call PRO-COM’s toll-free number on the front page.

Procom QN300RYLA — FLEXILBE HOSE diagram (page 15)
Fig. 30

EQUIPMENT SHUTOFF VALVE- Equipment shutoff valve with 1/8" NPT tap.

SPECIFICATIONS

QL300RYLA QN300RYLA QL300RYLA-W QN300RYLA-W Btu(Variable) Gas Type LP Gas Natural Gas Ignition Automatic Automatic Manifold Pressure 8"W.C. 3"W.C. Inlet Gas Pressure (In. of water)* Maximum 14" 10.5" Minimum 11" 5" Dimensions, Inches (H×W×D) Heater 25 4/5"×32 1/4” ×13" 25 4/5"×32 1/4” ×13" Carton 25 1/8"×34 1/8” ×12 7/8” 25 1/8"×34 1/8” ×12 7/8” Weight, lbs Stove 74 74 Shipping 83 83 voltage 120 120

*For purposes of input adjustment

watt 32 32

Page 16 of the Procom QN300RYLA user manual — OBSERVED PROBLEM POSSIBLE CAUSE
Page 16 · click to enlarge
Page 16

TROUBLESHOOTING

OBSERVED PROBLEM POSSIBLE CAUSE

REMEDY

1. No power to heater 2. No battery in transmitter or battery isn’t correctly assembly
1. Check the electric power 2. Place or replace the battery.

No spark when press in ignition button

When pressing the button of ignitor button is pressed, there is spark at ODS/pilot but no ignition

1. Gas supply turned off or equipment shut off valve closed 2. Air in gas lines when installed.
1. Turn on gas supply or open equipment shutoff valve

Press ON/OFF button again until air is removed . 2

2. 3. Contact local propane/LP gas company 4 Clean ODS/pilot (see Cleaning and Maintenance,page 13 ) or replace ODS/pilot assembly
3. Depleted gas supply
4. ODS/pilot is clogged
5. Gas regulator setting is not correct 6. Pilot electrude position is not correct 7. Wire is not correct or loosen 8 Gas valve is damage
5. Replace gas control 6. Replace Pilot 7. Check the wine and make wine correct. 8. Replace gas valve

ODS/pilot lights but flame is continuous igniting and the main burner couldn’t be lit.

1. Thermocouple connection loose at control board 2. Pilot flame not touching thermcouple which allows thermocouple to cool, causing pilot flame to go out. This problem could be caused by one or both of the following A) Low gas pressure B) Dirty or partially clogged ODS/ pilot 3. Thermocouple damaged 4. Control valve damaged
1. Hand tighten until snug, then tighten 1/4 turn more. 2. A) Contact local propane/LP gas company. B) Clean ODS/pilot ( see Cleaning

and Maintenance, page 13) or replace

ODS/pilot assembly 3. Replace thermocouple 4. Replace control valve

Burner does not light after ODS/pilot is lit

1. Burner orifice clogged 2. Inlet gas pressure is too low 3. Burner orifice diameter is too small 4. Thermocouple leads disconnected or improperly connected 5. Burners will not come in remote position

1.Clean burner (see Cleaning and Maintenance, page 13) or replace burner orifice. 2. Contact local propane/LP gas company 3. Replace burner orifice 4. Reconnect leads (see wiring diagram) 5. Replace battery in transmitter and receiver

Page 17 of the Procom QN300RYLA user manual — OBSERVED PROBLEM POSSIBLE CAUSE REMEDY
Page 17 · click to enlarge
Page 17

TROUBLESHOOTING

Continued

OBSERVED PROBLEM POSSIBLE CAUSE REMEDY

Delayed ignition burner 1. Manifold pressure is too low 2. Burner orifice clogged 1. Contact local gas company 2. Clean burner (see Cleaning and Maintenance, page 13)

Burner backfiring during combustion 1. Damaged burner 2. Gas regulator defective 1. Clean burner orifice (see Cleaning and Maintenance, page 13) 2. Replace gas regulator

Slight smoke or odor during initial operation

1. Residues from manufacturing processes 2. Not enough air 3. Gas regulator defective
1. Problem will stop after a few hours of operation 2. Check burner for dirt and debris. If found, clean burner ( see Cleaning and Maintenance , page 13) 3. Replace gas regulator

Dark residue on logs or inside of fireplace

1. Improper log placement 2. Air holes at burner inlet blocked 3. Burner flame holes blocked
1. Properly locate logs ( see installing logs , page 26) 2. Clean out air holes at burner inlet. Periodically repeat as needed. 3. Remove blockage or replace burner

Heater produces a clicking/ticking noise just after burner is lit or shut off

1. Metal expanding while heating or contracting while cooling
1. This is common with most heaters. If noise is excessive, contact qualified service person
Page 18 of the Procom QN300RYLA user manual — ILLUSTRATED PARTS BREAKDOWN QL300RYLA QN300RYLA QL300RYLA-W QN300RYLA-W
Page 18 · click to enlarge
Page 18

ILLUSTRATED PARTS BREAKDOWN QL300RYLA QN300RYLA QL300RYLA-W QN300RYLA-W

Procom QN300RYLA — ILLUSTRATED PARTS BREAKDOWN QL300RYLA QN300RYLA QL300RYLA-W QN300RYLA-W diagram (page 18)
Fig. 31
Page 19 of the Procom QN300RYLA user manual — PARTS LIST QL300RYLA QN300RYLA QL300RYLA-W QN300RYLA-W
Page 19 · click to enlarge
Page 19

PARTS LIST QL300RYLA QN300RYLA QL300RYLA-W QN300RYLA-W

Procom QN300RYLA — PARTS LIST QL300RYLA QN300RYLA QL300RYLA-W QN300RYLA-W diagram (page 19)
Fig. 32
Page 20 of the Procom QN300RYLA user manual — ILLUSTRATED PARTS BREAKDOWN QL300RYLA QN300RYLA QL300RYLA-W QN300RYLA-W
Page 20 · click to enlarge
Page 20

ILLUSTRATED PARTS BREAKDOWN QL300RYLA QN300RYLA QL300RYLA-W QN300RYLA-W

Procom QN300RYLA — ILLUSTRATED PARTS BREAKDOWN QL300RYLA QN300RYLA QL300RYLA-W QN300RYLA-W diagram (page 20)
Fig. 33
Page 21 of the Procom QN300RYLA user manual — PARTS LIST QL300RYLA QN300RYLA QL300RYLA-W QN300RYLA-W
Page 21 · click to enlarge
Page 21

PARTS LIST QL300RYLA QN300RYLA QL300RYLA-W QN300RYLA-W

Procom QN300RYLA — PARTS LIST QL300RYLA QN300RYLA QL300RYLA-W QN300RYLA-W diagram (page 21)
Fig. 34
Page 22 of the Procom QN300RYLA user manual — BOTTOM PANEL
Page 22 · click to enlarge
Page 22

PLACING INSTRUCTION

Follow the procedures below and the instruction drawings to put log sets in place to the gas stove(indoor vent-free).

THEN REMOVE SCREEN AND TAKE OUT THE LOG’S PACKAGE

THE LOG’S PACKAGE IS LOCATED INSIDE THE UNIT

Procom QN300RYLA — THEN REMOVE SCREEN AND TAKE OUT THE LOG’S PACKAGE diagram (page 22)
Fig. 35
Procom QN300RYLA — THEN REMOVE SCREEN AND TAKE OUT THE LOG’S PACKAGE diagram (page 22)
Fig. 36

FIRST REMOVE TWO TOP SCREWS FROM SCREEN

Procom QN300RYLA — FIRST REMOVE TWO TOP SCREWS FROM SCREEN diagram (page 22)
Fig. 37

BOTTOM PANEL

Page 23 of the Procom QN300RYLA user manual — Q SERIES LOG SET
Page 23 · click to enlarge
Page 23
Procom QN300RYLA — Q SERIES LOG SET diagram (page 23)
Fig. 38

Q SERIES LOG SET

INSTALLATION INSTRUCTIONS

Page 24 of the Procom QN300RYLA user manual — FIG(3) FIG(4)
Page 24 · click to enlarge
Page 24

INSTALLATION INSTRUCTIONS FOR LOG SETS

1. All logs

Procom QN300RYLA — 1. All logs diagram (page 24)
Fig. 39 · 1. All logs
Procom QN300RYLA — 1. All logs diagram (page 24)
Fig. 40 · 1. All logs

FIG(1) FIG(2)

1. Install the log 1 on the left rear angle iron. see FIG(2)
Procom QN300RYLA — FIG(1) FIG(2) diagram (page 24)
Fig. 41
Procom QN300RYLA — FIG(1) FIG(2) diagram (page 24)
Fig. 42

FIG(3) FIG(4)

2. Install the log 2 on the right rear angle iron. see FIG(3)
3. Install the log 3 on the front angle iron. See FIG(4).
Page 25 of the Procom QN300RYLA user manual — FIG(5)
Page 25 · click to enlarge
Page 25
4. Insert the pinhole on the upper part of log 4 into the pin on the left side of log 1. Place the lower part of log 4 on the flat roof at the left side of log 3 See FIG(5).
Procom QN300RYLA — FIG(5) diagram (page 25)
Fig. 43
Procom QN300RYLA — FIG(5) diagram (page 25)
Fig. 44

FIG(5)

FIG(6)

4. Insert the pinhole on the upper part of log 5 into the pin on the log 2. Place the lower part of log 5 on the flat roof at the left side of log 3 . See FIG(6).
Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Procom QN300RYLA

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Procom QN300RYLA

Be the first to ask — other owners or our team will answer.

Original document

Procom QN300RYLA manual PDF

25 pages·2.5 MB·Stove·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…