The scale looks like this:
Scale Power Supply Unit (in its own box) User Guide Rates PROM (You may or may not be supplied with a Rates PROM. If one is supplied, fit it at step 4 or your scale may display incorrect rates. If one is not supplied, your scale has been pre-programmed with the current rates and will function without one until the next postage rate change). Meter Cable (only supplied if you ordered a Pitney Bowes Postage Meter at the same time as your scale)
Rate PROM (if supplied)
3. Remove packing
Lift the platform and remove the packing material.
Place the scale near a wall outlet and within cable reach of your postage meter (if you have one). Ensure the scale location is a flat, stable surface free of draughts and the scale is not touching objects that may affect the weight reading.


5. Locate the plug ports
If you have been supplied with a PROM, slide it into its slot ensuring the opening in the PROM handle is in the top right corner. Press it firmly until it snaps into place. Refit platform. If a rate PROM has not been supplied, you can omit this stage.
Locate the plug ports under the front of the scale and plug in the small end of the power cable.


7. Tuck the cable(s) into the cable guides
If using a Postage Meter, plug the small end of the meter cable into the scale.
Tuck the cable(s) under the guides on the bottom of the scale. Turn the scale back onto its feet.




Level the scale by turning the scale feet until the levelling bubble is centred and the scale does not wobble.
If using a postage meter, connect the large end of the meter cable to the the meter as shown. Tighten the thumbscrews securely.
If your postage meter is fitted with an optional Datalink unit, connect the large end of the meter cable to the lower connector on the Datalink unit. Tighten the thumbscrews securely.


Plug the power supply unit into the wall outlet and turn power on. After a short power-up sequence, the display appears as shown.



After entry of the location code, the scale goes through a short test sequence, then displays 0000g and the Select Category arrow flashes. This is the ready mode.
If your postage meter has an optional Datalink unit fitted, configure it now as described in the Datalink Operating Guide.

Congratulations! You have successfully installed your Pitney Bowes Scale. For information on using the scale, refer to the Operating Guide.
If you have existing Pitney Bowes equipment that needs to be returned, follow the
Scale ready mode

Use these instructions if you have a N521 (2kg), N620/N621 (5kg) or a N720/N721 (12kg) scale
The scales look like this:


N620, N621, N720, N721
1. Make sure you have:
Scale Power Supply Unit (in its own box) User Guide Rate PROM Meter Cable (only if you ordered a Pitney Bowes Postage Meter at the same time as your scale)
User Guide Meter Cable Rate PROM

Place the scale near a wall outlet and within cable reach of your postage meter (if you have one). Ensure the scale location is a flat, stable surface, free of draughts and the scale is not touching objects that may affect the weight reading.
Power Supply · Unit

4. Install the Rate PROM
Lift the platform and remove the packing material.
Slide the Rate PROM into its slot ensuring the opening in the PROM handle is in the top right corner. Press it firmly until it snaps into place. Refit platform.


Locate the plug ports under the front of the scale and plug in the small end of the power cord.



If using a Postage Meter, plug the small end of the meter cable into the scale.



7. Tuck the cable(s) into the cable guides
Tuck the cable(s) under the guides on the bottom of the scale. Turn the scale back onto its feet.



Level the scale by turning the scale feet until the levelling bubble is centred and the scale does not wobble.
Adjustable Feet (4)

If your postage meter is fitted with an optional Datalink unit, connect the large end of the meter cable to the lower connector on the Datalink unit. Tighten the thumbscrews securely.



Plug the power supply unit into the wall outlet and turn power on. After a short power-up sequence, the display appears as shown.


After entry of the location code, the scale goes through a short test sequence, then displays 0g and the Select Category message. This is the ready mode.

If your postage meter has an optional Datalink unit fitted, configure it now as described in the Datalink Operating Guide.

Congratulations! You have successfully installed your Pitney Bowes Scale. For information on using the scale, refer to the Operating Guide.
If you have existing Pitney Bowes equipment that needs to be returned, follow the


The scale looks like this:
Scale control module and platform Power Supply Unit (in its own box) User Guide Rate PROM Meter Cable (only if you ordered a Pitney Bowes Postage Meter at the same time as your scale)
User Guide Meter Cable

Place the platform within cable reach of the Control Module. Ensure the platform location is a flat, stable surface, free of draughts and the platform is not touching objects that may affect the weight reading.
Lift the cover straight up from the platform unit. Level the platform by turning its feet until the levelling bubble is centred and the platform doesn’t wobble.


4. Remove the control module cover
Place the cover on the weighing platform. Press down on each corner to be sure it is completely seated.
Remove the cover from the top rear of the control module and set aside.


6. Connect weighing platform to control module
Slide the Rate PROM into the slot with the unlabelled side facing you. Press it firmly until it snaps into place. Refit cover.
Turn the control module over and plug the small end of the weighing platform cable into the back of the module.

Underside of Control Module

Locate the plug ports under the front of the control module and plug in the small end of the power cable.

If using a Postage Meter, plug the small end of the meter cable into the control module.

Tuck the cable(s) under the guides on the bottom of the control module. Turn the module back onto its feet.


10.Connect the meter cable to the postage meter If using a postage meter, connect the large end of the meter cable to the the meter as shown. Tighten the thumbscrews securely.
If your postage meter is fitted with an optional Datalink unit, connect the large end of the meter cable to the lower connector on the Datalink unit. Tighten the thumbscrews securely.



Plug the power supply unit into the wall outlet and turn power on. After a short power-up sequence, the display appears as shown.


After entry of the location code, the scale goes through a short test sequence, then displays 0g and the Select Category message. This is the ready mode.

If your postage meter has an optional Datalink unit fitted, configure it now as described in the Datalink Operating Guide.

Congratulations! You have successfully installed your Pitney Bowes Scale. For information on using the scale, refer to the Operating Guide.
If you have existing Pitney Bowes equipment that needs to be returned, follow the

Calls are charged at 60p per minute
The Pinnacles, Harlow, Essex, CM19 5BD
Form No. SDC337 RevD (3-01) Printed in England © Pitney Bowes Limited, 2001
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.