FCC Notice This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio fre- quency and energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Third Edition, September 2000 ©2000 Pitney Bowes Inc.
All rights reserved. This book may not be reproduced in whole or in part in any fashion or stored in a retrieval system of any type or transmitted by any means, electronically or mechanically, without the express, written permission of Pitney Bowes.
We have made every reasonable effort to ensure the accuracy and usefulness of this manual; however, we cannot assume responsibility for errors or omissions or liability for the misuse of misapplication of our products.
Due to our continuing program of product improvement, equipment and material specifications as well as performance, features are subject to change without notice.
Integra is a trademark of Pitney Bowes Inc.
SV60418 Rev. C 9/00




A BOUT Y OUR I NTEGRA ™ 5 S CALE
The Integra™ 5 is a five-pound capacity scale with keypad and display. It determines the weight of a mailpiece placed on the platter and calculates rates and fees based on selections you make from the keypad. The scale can also interface with and display a variety of information about your Pitney Bowes electronic postage meter.
The scale enters sleep mode if it remains inactive at zero weight for more than five minutes. In this state, the display clears and all information retained from the previous transaction clears.
Follow the normal safety precautions for all office equipment when using this scale.
❒ Use only the AC adaptor/power supply included with this scale.
❒ To protect against electric shock, plug the AC adaptor into a properly grounded wall outlet only.
❒ The wall outlet should be near the scale and easily accessible.
❒ Avoid using wall outlets controlled by wall switches or shared with other equipment.
❒ Do not route the AC adaptor cable over sharp edges or trap it between furniture.
❒ Do not remove covers; if the scale has been dropped or has otherwise had the enclosure stressed in any way, call Pitney Bowes at 1-800-537-2488.
❒ Do not place lighted candles, cigarettes, cigars, etc., on the scale.
❒ Use the equipment only for its intended purpose.


Carrier, Scale, & Meter Control Keys Menu Selection Keys
Enter



Direct questions and requests for service to the Pitney Bowes Diagnostic Center at
1-800-537-2488.
Please be near your scale when you call.
Representatives are available Monday through Friday between 8:00 a.m. and 8:00 p.m. Eastern time.
Visit our website for the latest updates and
frequently asked questions about Integra.
The Pitney Bowes Corporate page is at: http://www.pb.com
When connected:




The scale's easy-to-follow menu system guides you through each transaction and applies the information and features you select. Arrows appearing on the right-hand side of the screen indicate the presence of more choices. Press the up or down scroll keys at the right of the display to view next or previous choices.
When you select an item from the menu, the display registers your selection, displays the postage amount, and advances to the next menu screen if appropriate. Press the CE/C key once to return to the previous screen.
When entering alphabetic information, such as names of countries or passwords, you must use a combination of alphanumeric keys, located on the righthand side of the scale, and the color-coded keys above them.
For example, when sending mail to Spain, at the Enter Country prompt:
First, press and release the blue key
Next, press and release the S key
The scale displays the countries that begin with S.
Remember to press the color key before each press of an alpha key.

After installing your scale and becoming familiar with the location of the keys, press the Setup key and review the list of user default setup options (shown at right).
User Setup -Exit -ON Autoclear Class -ON ClrZoneNewClass -OFF Auto Weigh Hold -Supervisor Setup -Service Setup
Service Setup is accessible only by Pitney Bowes Customer Service Representatives.
User Options are set to either on or off. They concern information you can retain from mailpiece to mailpiece. The options are defined below.
Autoclear Class When on, class information clears when you remove a mailpiece from the scale.
Autoclear Zone When on, zone information clears when you (Displays only when remove a mailpiece from the scale. Autoclear Class is off.)
Clear Zone New Class When on, the zone clears when you select a new class.
Auto Weight Hold When on, retains the weight of an item for a brief time after the item is removed from the scale.
After exiting setup mode, the scale reinitializes and returns to ready mode.
Option Function

Certain options are password-protected for supervisory control. They are: Configure Scale and BMC Intra ZIP. You can access these options by pressing the Setup key and selecting Supervisor Setup.
After selecting Supervisor Setup, at the Enter Password prompt:
→
Supervisor Setup Option Description
Install Scale Used to enter a ZIP Code during the installation process to establish the scale's geographic location.
Other Language When on, prompts display in Spanish.
Inscriptions When on, allows you to include an inscription in the meter imprint.
Accounting When on, communicates with connected mail data system about account data. When off, communicates with connected meter about account data.
Vibration Filter Turn on this option only in areas of excessive vibration to aid the display of stable weight.
Create Intra ZIP Used to enter ranges of ZIP Code locations within a bulk mailing center.
Green Green Red · Configure Scale · BMC Intra ZIP

The following assumes you have completed the installation instructions included with your scale. If not, please do so now.
When the scale is ready to weigh a mailpiece, the display is in ready mode as shown here.
0lb 0.0oz Select Rate
Refer to the examples below for processing different classes of mail.
Examples: — First Class
4. Either select a fee or ignore these choices. If you select a fee, its cost is added to the postage amount and the new total displays. (If your scale is connected to a meter that supports electronic delivery confirmation, you have the option of selecting this service from the scale for certain classes of mail. When you press the Tape or Meter Set keys on the scale, the meter prompts for any additional delivery confirmation information required to complete the delivery confirmation transaction. Enter this information at the meter.)
mailing process for single pieces.

You may manually enter a monetary amount (called the "Dollar Add" amount) up to six digits for fees not listed on the scale. The amount you enter is added to the total.
For example, to add an unlisted fee:
With an item on the scale,
For example, if you enter 3 (with no decimal point), the scale interprets the amount as $0.03.
0lb 0.9oz $ 0.32 1st Cl/Priority
then press and release
Dollar Add:
$3.
for $3.00. The amount displays at the bottom right of the screen.
To cancel the Dollar Add amount:
Press the softkey next to the Dollar Add selection. The fee is deducted from the postage value.
Press and release

The Accounting feature allows you to assign postage to the accounts set up in your meter. When you designate an account, the postage and piece information are updated and are reflected in Account Status accessed with the Meter Functions key.
Account
At any point in calculating postage and with the meter on:
To send an international letter by air:
With the scale in ready mode and weight on the scale,,
With the scale in ready mode and weight on the scale,
When you finish making menu choices, note the total postage amount. You may either transfer the amount to a meter or end the transaction by removing the mailpiece.

For parcel post mail, the Select ZIP/Select Zone prompt displays. Choose one option.
Zone Codes
For ZIP: Enter the first three digits of the destination ZIP Code; press Enter.
For Zone: If you know the destination zone, enter the zone number and press Enter.
The ZIP Code or zone number, postage amount, and options for more services display.
With the scale in ready mode,

The scale has a number of special features that help you process mail quickly and efficiently. These features are explained below and accessed by pressing the Scale Functions key and selecting from the menu list.
0lb 0.0oz
Scale Functions -Metric Weight -Fee Recall -Weight Hold -Manual Weight Entry -Parts Count
With an item on the scale:
Generating Multiple Tapes (Not in menu list)
With weight on the scale:

The Fee Recall option allows you to review the fees included in the total postage amount. It also displays the item value for verification.
For example, to recall insurance value or Dollar Add amount:
With the total postage amount displayed:
This function allows you to enter the known weight of an item without putting the item on the scale. You can then generate a tape on the meter and apply it to the mailpiece.
For 4 lbs. 2 oz. enter 4 0 2 0; press Enter. For 3 lbs. 2.5 oz., enter 3 0 2 5; press Enter.
The scale returns to the ready mode.

With the Parts Count function, you can obtain a count of like items based on the weight of a known quantity of those items. Depending on the shape and quantity of the parts you are weighing, you may need to place them in a container. You can deduct the weight of the container, and count and weigh the parts at the same time. If you are not using a container, start with Step 2 below.

To exit Parts Count, remove parts from scale and press CE/C. If you used a container, remove it from the scale and press the Zero key.
The weight hold feature is useful when weighing large envelopes that block the display. This feature retains the weight reading for a brief time after you remove an item from the scale. It allows you to continue selecting class and fees even though the item is no longer on the scale. Pressing any key (for example, to select a class or fee) other than zero extends the weight hold time for that transaction.
You may activate weight hold mode in two ways: manually with the Scale Functions key or automatically through setup.

To use the weight hold feature for one transaction:
Result: displays to the right of the weight field.
Result: The weight reading is retained for a brief period.
To exit manual weight hold, wait a few seconds until the hold feature times out or press Zero or, to cancel the entire transaction, press CE/C.
To enable automatic weight hold feature for every transaction:
Result: The scale reinitializes and returns to ready mode. No indication of the weight hold feature displays. Thereafter, whenever you place an item on the scale, its weight will be retained briefly when you remove it from the platter.
To disable weight hold, repeat the above steps, noting that selecting Auto Weigh Hold in Step 2 results in Off displaying next to the feature.

The Integra 5 scale interfaces with postage meter models 6500, 6900, 6909, A900, B700, and B900. Depending on the functions available with your meter, you can initiate and display the following meter functions via the scale by pressing the Meter Functions key.
Select Funds to read the amount of funds available/used and the total number of mailpieces processed. Press CE/C to return to the Meter Functions screen.
Account Status allows you to view the status of the account to which the meter is set. It displays the account number, the amount of money in the account, and the number of pieces processed against that account.
Choose Select Account to pick from a list of other available account numbers.
Choose Clear Account to clear value and pieces information at the end of a reporting period.
Press CE/C twice to return to the ready screen.
(Must be turned on in Supervisor Setup.) Select Inscriptions to display a list of inscriptions installed in your meter. The one you choose appears on the mailpiece. Select None to clear an inscription.


Diagnosing Problems ........................................................22

C LEARING E RROR M ESSAGES
Occasionally, error messages display on the screen. Sometimes they identify an incorrect entry and indicate corrective action. To clear most errors:
If the error does not clear, call the Pitney Bowes Diagnostic Center at 1-800-537-2488.
You may be able to diagnose and correct problems yourself by referring to the symptoms vs. recommendations chart on the next page. If performing the suggested action is not successful, call the Pitney Bowes Diagnostic Center.

Probable Symptom Cause Recommendation
Blank screen. A. Sleep mode. Touch the weight platform.
B. Scale power supply Check power supply is firmly connected unplugged. at each end. Remove plug from wall outlet, wait 10 seconds; reconnect.
C. Rate card not firmly Disconnect power, remove card, rub a in slot. pencil eraser over the gold contacts to clean them, insert card as directed on pg. 26, reconnect power.
Scale does not Interference with Press Zero key. return to zero. scale platter.
Scale displays Out of calibration or Check for foreign matter under scale zero wgt only. mechanical inter- platform. Call the Diagnostic Center. ference.
Scale display does Platform incorrectly Ensure platform correctly seated. Check for not reach five seated or mechanical foreign matter under platform. pounds. interference.
Inconsistent A. Air currents moving Move scale to another location. weights. across platform.
B. Platform or item Clear area around scale. being weighed touching another object.
C. Vibrations affecting Turn on vibration filter. scale.
Decimal point on Low funds in meter. Refill meter. postage amount is blinking.



Pages referenced in this manual — manufacturer, support and downloads.
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| Blank screen. | A. Sleep mode. | p.27 | |
| Blank screen. | B. Scale power supply unplugged. | p.27 | |
| Blank screen. | C. Rate card not firmly in slot. | p.27 | |
| Scale does not return to zero. | Interference with scale platter. | p.27 | |
| Scale displays zero wgt only. | Out of calibration or mechanical inter- ference. | p.27 | |
| Scale display does for not reach five pounds. | Platform incorrectly seated or mechanical interference. | p.27 | |
| Inconsistent weights. | A. Air currents moving across platform. | p.27 | |
| Inconsistent weights. | B. Platform or item being weighed touching another object. | p.27 | |
| Inconsistent weights. | C. Vibrations affecting scale. | p.27 | |
| Decimal point on postage amount is blinking. | Low funds in meter. | p.27 |