Thank you for purchasing Body Fat Monitor with Scale. Before using this unit for the first time, please be sure to read this instruction manual carefully and use the unit properly. Please keep this instruction manual on hand for future reference.
9042756-8C



Easy-to-Understand Display This unit calculates and displays the body fat percentage by using the Bioelectrical Impedance (BI) method. The displayed values for body fat and BMI* (Body Mass Index) are indicated in four ranges: “–”, “0”, “+”, “++”.
BI method: Bioelectrical Impedance method (full explanation on page 7) BMI: Body Mass Index.
This Index indicates the ratio between weight and height of a person. Common standard in the medical profession. Formula (in metric): weight (kg) / height (m) / height (m).
Measurement is fast and simple. After entering the data, a measurement can be started by simply pushing the power switch, selecting your personal ID number and stepping onto the measurement platform.
The calculated results are shown in an easy-to-see display. Body fat percentage and body mass index are shown simultaneously in an easy-to-see large digital display and a bar display that can be read at a glance.
The memory function stores up to 4 personal profiles The memory function can store individual settings (age, gender, and height) for up to four people.
A simple press of the GUEST/MEMORY button displays the measurement results from the previous measurement.

Never use this unit in combination with medical electronic devices such as: (1) Medical electronic implants such as pacemakers.
(2) Electronic life support systems such as an artificial heart/lung. (3) Portable electronic medical devices such as an electrocardiograph. • This unit may cause the above mentioned medical electronic devices to malfunction.
Read and follow the “Important information regarding Electro Magnetic Compatibility (EMC)” in the Technical Data Section.
Save these instructions for future reference.

1.What You Should Know When Using This Unit
Body fat percentage refers to the amount of body fat mass in regards to the total body weight expressed as a percentage. This OMRON BF400 will provide your specific body fat percentage and body weight. It is also an excellent tool to estimate your body fat percentage and measure body weight on a continuous schedule. Body fat percentage (%) = {Body fat mass / Body weight} x 100

Body fat reading is affected by the change of water content in the body. A person’s hydration level and blood circulation may have an effect on their body fat reading. In the table below are some situations which could affect the reading.


If the soles of your feet are dry or the temperature of your feet or the electrodes are extremely cold, it will not be possible to obtain stable measurements, which may lead to display error indication or inaccurate results. Please pay special attention in winter because the air is dry and/or the temperature is low.

Understanding the normal changes in your body fat percentage can help you in preventing or reducing obesity. Being aware of the times when the body fat percentages shift within your own daily schedule will assist you in obtaining an accurate trending of your body fat. It is recommended to use this unit in the same environment and daily circumstances. (See chart)

Before lunch and about 2 hours or more after breakfast
In the afternoon about 2 hours or more after lunch and before taking a bath or eating dinner
Before going to bed and about 2 hours or more after dinner

1.What You Should Know When Using This Unit
The OMRON BF400 estimates the body fat percentage by the Bioelectrical Impedance (BI) method.
What is the Bioelectrical Impedance method? Muscles, blood vessels and bones are body tissues having a high water content that conduct electricity easily. Body fat is tissue that has little electric conductivity. The BF-400 sends an extremely weak electrical current of 50 kHz and less than 500 µA through your body to determine the amount of fat tissue. This weak electrical current is not felt while operating the BF400. The Bioelectrical Impedance Method safely combines the electric resistance with the distance of the electricity conducted. Correct posture and consistent measuring conditions need to be maintained for the best results.
How to estimate the body fat percentage. DXA (Dual Energy X-Ray Absorptiometry), has been the established method for accurate evaluation of body composition. OMRON has used research information from several hundred people using the DXA method to develop the formula by which the BF-400 works. The body fat mass and body fat percentage is calculated by a formula that includes five factors: electric resistance, height, weight, age and gender.
What is the DXA method? The DXA method uses two different frequency X-Rays and rates of absorption of the body and determines the value based on the difference between the two.
People who may get erratic results There are certain conditions, such as with dialysis patients, when significant differences may occur between the estimated and actual body fat values. These differences may be related to consistently changing ratios of body fluid and/or body composition. Also refer to: “Avoid Taking Measurements Under the Following Conditions” and “Cases When the Calculated Results May Differ from Actual Body Fat Percentages” in section 5.

2.Know Your Unit

A. Power Switch B. Heel Electrodes C. Electrodes D. Measurement Platform E. Display F. USER Button G. GUEST/MEMORY Button H. (Down) Button I. SET Button J. (Up) Button

2.Know Your Unit

R. Memory Indicator S. Age Indicator T. Height Indicator U. Gender Indicator V. Measurement Progress / Body fat
:Weight :Body Fat Percentage :BMI N. Measurement Results O.GUEST Indicator P. Personal ID Number Q.Battery Low Indicator

W.Four AA manganese batteries X. Instruction Manual (this document) Y. Warranty Card

3.Inserting and Replacing the Batteries

Make sure that their polarity (+/–) is aligned with the polarity (+/–) indicated in the battery compartment.
personal ID information even when the batteries are replaced.
Battery life - Four AA batteries will last approximately 1 year (when measurements are made four times a
day). - Because the supplied batteries are for trial use only, they may have a shorter life. Warning!
If battery fluid should get in your eyes, immediately rinse with plenty of clean water. Consult a doctor immediately. Caution!

4.Setting and Adjusting Personal Data

“CAL” blinks on the display, then the display changes to 0.0 kg. Wait until 0.0 kg appears on the display.

The ID number changes with each press of the USER button as follows.
If no information has been entered for a personal ID number, the personal ID number and the three icons for gender, age, and height blink, as shown in the illustration. If information has already been entered, only the personal ID number blinks.

The default setting for the age setting appears on the display.

4.Setting and Adjusting Personal Data
Age 1) Press the or button to adjust the age setting to the desired age. 2) Press the SET button to confirm the setting.

The age setting is set, and the gender icons blink on the display.
Gender 3) Press the or button to adjust the gender setting to the desired gender. 4) Press the SET button to confirm the setting.
The gender setting is set, and the default height setting blinks on the display.
Height 5) Press the or button to adjust the height setting to the desired height. 6) Press the SET button to confirm the setting.
After you confirm the setting for height, the unit displays the settings for all three settings then 0.0 kg appears on the display.
You can now start taking measurements. (Proceed to Step 3 in “5.1 Taking a Measurement” on page 15.)
If the personal information stored for any of the personal ID numbers (1-4) changes, the settings for that ID will need to be adjusted.

4.Setting and Adjusting Personal Data
The age setting appears on the display and the age setting blinks.
Press the and buttons to adjust the settings for each category and then press the SET button to confirm each setting.
Then you can now start taking measurements. (Process to Step 3 in “5.1 Taking a Measurement” on page 15.)
The age setting appears on the display and the age setting blinks.

“Clr” will appear in the display and the registered information is deleted from memory.

5.Using the Unit

“CAL” blinks on the display, then the display changes to 0.0 kg. Wait until 0.0 kg appears on the display.
If you have a personal profile (Personal ID) registered on the unit:
If you do not have a personal profile registered on the unit (Guest mode):


The GUEST indicator appears on the display and the age setting blinks. 2. Enter the information for your age, gender and height. (Step 4 in “4. Setting and Adjusting Personal Data” on page 12)
Press the or buttons to adjust the settings for each category and then press the SET button to confirm each setting.
After you confirm the setting for height, the unit displays the settings for all three settings then 0.0 kg appears on the display.
“CAL” blinks on the display, then the display changes to 0.0 kg. Wait until 0.0 kg appears on the display.

5.Using the Unit
Make sure that you are bare foot and that the soles of your feet are clean.
Make sure that your feet are correctly positioned on the electrodes and that you are standing with your weight evenly distributed on the platform.
Remain still and do not move until the measurement is complete.

The display will show your weight and then the weight result will blink. The indicators in the measurement progress bar at the bottom of the display will gradually appear, from left to right.
After measurement completes, your weight is displayed again. At this point you may step off the measurement platform.
After three seconds have passed since your weight was displayed, the three measurement results are automatically displayed repeatedly in the following order: WEIGHT -> %FAT -> BMI -> WEIGHT (again).
Refer to section 5.3 on how to interpret the %FAT and BMI results.
only be displayed for ages between 20 and 79 years.

Your feet

5.Using the Unit

If a measurement is made under the following physical conditions, the estimated body fat percentage may differ significantly from the actual one because the water content in the body is changing.

Immediately after vigorous exercise Immediately after a bath or sauna
After drinking alcohol After drinking a large amount of water or after a meal (1 to 2 hours)

5.Using the Unit
Calculated results for the following groups of people may vary due to consistently changing amounts of water and tissue density within their bodies.

Patients with osteoporosis who have very low bone density

To help ensure reliable results, please observe the following points when taking a measurement. • Stand upright on the measurement platform with your weight evenly distributed over the electrodes. Do not stand on or near the edge of the platform.


5.Using the Unit
Displays the body fat mass as the percentage of body weight.

Body fat percentage classification Displays “–”, “0”, “+”, “++”
20-39 < 21.0 21.0 - 32.9 33.0 - 38.9 39.0 40-59 < 23.0 23.0 - 33.9 34.0 - 39.9 40.0 60-79 < 24.0 24.0 - 35.9 36.0 - 41.9 42.0
20-39 < 8.0 8.0 - 19.9 20.0 - 24.9 25.0 40-59 < 11.0 11.0 - 21.9 22.0 - 27.9 28.0 60-79 < 13.0 13.0 - 24.9 25.0 - 29.9 30.0
Based on NIH/WHO guidelines for BMI Based on Gallagher et al., American Journal of Clinical Nutrition, Vol. 72, Sept. 2000
BMI BMI is an internationally used index to show the body condition by checking the balance between the height and the weight. It is calculated by the following formula: BMI in metric = weight (kg) / height (m) / height (m)

BMI BMI (Designation by the WHO) BMI Classification Bar BMI Rating
7.0 - 10.7 10.8 - 14.5 14.6 - 18.4
18.5 - 20.5 20.6 - 22.7 22.8 - 24.9
25.0 - 26.5 26.6 - 28.2 28.3 - 29.9
30.0 - 34.9 35.0 - 39.9 40.0 - 90.0
The above-mentioned indices refer to the values for obesity judgment proposed by the WHO, the World Health Organization.


“CAL” blinks on the display, then the display changes to 0.0 kg. Wait until 0.0 kg appears on the display.
Make sure that you are standing with your weight evenly distributed on the platform.
Remain still and do not move until the measurement is complete.
If you do not step onto the measurement platform within five minutes of 0.0 kg appearing on the display, the unit will automatically turn itself off.

At this point you may step off the measurement platform.

Your feet

6.Error Displays
Error Display Cause Correction
Make sure that you are standing on the measurement platform correctly and try again.
Your feet were not positioned over the electrodes.
The measurement position was not stable or your feet were not placed correctly.
Remain still and do not move during measurement.
Slightly moisten the soles of your feet with a damp towel and try again.
Feet are too dry.
Check that the registered settings for height, age and gender are correct. If this error still appears and the height, age, and gender settings are correct, measurements cannot be taken.
The body fat percentage and BMI values are outside the measurement range noted in the specifications on page 23.
Make sure that you are standing on the measurement platform correctly and try again.
Your feet were not positioned over the electrodes.
Remove the batteries then reinsert them after waiting for at least one minute. Push the power switch to turn the unit on, and repeat the measurement. If this error still occurs, consult your OMRON service representative.
An operating error has occurred.
You stepped onto the measurement platform before 0.0 kg was displayed.
Wait until 0.0 kg is displayed before stepping onto the measurement platform.
The unit was moved before 0.0 kg was displayed.
Do not move the unit until 0.0 kg is displayed.
Movement during measurement. Do not move till measurement is complete.
Your weight is over 150.0 kg. This unit can only be used by people weighing less than 150.0 kg.

7.Troubleshooting
Are the batteries worn out? Replace all four “AA” batteries with new ones.
Nothing is displayed when the power switch is pushed.
Are the batteries correctly aligned? Insert the batteries correctly.
An error message (Err1 to Err) is displayed and measurements cannot be taken.
Refer to “6. Error Displays” on page 21.
Is the unit placed on a carpet or other soft flooring? Place the unit on a hard, level floor. Is the floor surface is uneven?
The weight values vary widely for each measurement.
The battery low indicator appears. The battery power is low. Replace all four “AA” batteries with new ones.
Refer to “Avoid Taking Measurements Under the Following Conditions” and “Cases When the Calculated Results May Differ from Actual Body Fat Percentages” on pages 16 to 17.
The %Fat value displayed is abnormally high or low.
Other conditions. Remove the batteries, then reinsert them after waiting for at least one minute.
To protect your unit from damage, please observe the following: • Do not wipe the unit with benzene, gasoline, paint thinner, alcohol, or other volatile solvents.
Problem Cause Correction

9.Technical Data
Name BF400 Product Body Fat Monitor with Scale Model HBF-400-E Display Weight: 0.0 to 150.0 with 100g increments Body fat percentage: 5.0 to 60.0% BMI: 7.0 to 90.0 Body fat percentage / BMI classification: – (Low/Underweight) / 0 (Normal) / + (High/Pre-obese) / ++ (Very High/ Obese) 12 levels of Bar display *The age range for the body fat percentage classification is 20 to 79 years old. Weight Accuracy 0.0 kg to 40.0 kg: ± 400 g 40.1 kg to 150.0 kg: ± 1% Body Fat Percentage Accuracy SEE ± 4%
Set Ranges Height: 100 to 199.5 cm Age: 18 to 80 years old Gender: Male/Female *Although the age setting can be set to between 18 and 80 years, the body fat percentage reading will only be displayed for ages between 20 and 79 years. Power Supply 4 AA batteries (You may also use 4 AA alkaline batteries) Battery Life Approximately 1 year (when used four times a day) Operating Temperature and Humidity 10°C to 40°C, 30% to 85% RH
Storage Temperature and Humidity -20°C to 60°C, 10% to 95% RH
External Dimensions Approximately 310 (w) x 303 (h) x 58 (d) mm Weight Approximately 2.1 kg (including batteries) Package Contents 4 AA manganese batteries, instruction manual, warranty card
This device fulfills the provisions of EC directive 93/42/EEC (Medical Device Directive).
Please read the instruction manual carefully before using the device.
Correct Disposal of This Product (Waste Electrical & Electronic Equipment)
This marking shown on the product or its literature, indicates that it should not be disposed with other household wastes at the end of its working life. To prevent possible harm to the environment or human health from uncontrolled waste disposal, please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources.
Household users should contact either the retailer where they purchased this product, or their local government office, for details of where and how they can take this item for environmentally safe recycling.
Business users should contact their supplier and check the terms and conditions of the purchase contract. This product should not be mixed with other commercial wastes for disposal.
This product does not contain any hazardous substances.
= Type BF

9.Technical Data
With the increased number of electronic devices such as PC.s and mobile (cellular) telephones, medical devices in use may be susceptible to electromagnetic interference from other devices. Electromagnetic interference may result in incorrect operation of the medical device and create a potentially unsafe situation. Medical devices should also not interfere with other devices.
In order to regulate the requirements for EMC (Electro Magnetic Compatibility) with the aim to prevent unsafe product situations, the EN60601-1-2 standard has been implemented. This standard defines the levels of immunity to electromagnetic interferences as well as maximum levels of electromagnetic emissions for medical devices.
This medical device manufactured by OMRON Healthcare conforms to this EN60601-1-2:2001 standard for both immunity and emissions. Nevertheless, special precautions need to be observed: • Do not use mobile (cellular) telephones and other devices, which generate strong electrical or electromagnetic fields, near the medical device. This may result in incorrect operation of the unit and create a potentially unsafe situation. Recommendation is to keep a minimum distance of 7 m. Verify correct operation of the device in case the distance is shorter.
Further documentation in accordance with EN60601-1-2:2001 is available at OMRON Healthcare Europe at the address mentioned in this instruction manual. Documentation is also available at www.omron-healthcare.com

OMRON HEALTHCARE CO., LTD. 24, Yamanouchi Yamanoshita-cho, Ukyo-ku, Kyoto, 615-0084, Japan
OMRON HEALTHCARE EUROPE B.V. Kruisweg 577, 2132 NA Hoofddorp, The Netherlands www.omron-healthcare.com
OMRON HEALTHCARE UK LTD. Opal Drive Fox Milne, Milton Keynes MK15 0DG, United Kingdom
OMRON Medizintechnik Handelsgesellschaft mbH John-Deere-Str. 81a, 68163 Mannheim, Germany www.omron-medizintechnik.de
OMRON SANTÉ FRANCE SAS 14, rue de Lisbonne, 93561 Rosny-sous-Bois Cedex, France
Made in China
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| Nothing is displayed when the power switch is pushed. | Are the batteries worn out? | Replace all four “AA” batteries with new ones. | p.22 |
| Nothing is displayed when the power switch is pushed. | Are the batteries correctly aligned? | Insert the batteries correctly. | p.22 |
| An error message (Err1 to Err) is displayed and measurements cannot be taken. | Refer to “6. Error Displays” on page 21. | p.22 | |
| The weight values vary widely for each measurement. | Is the unit placed on a carpet or other soft flooring? | Place the unit on a hard, level floor. | p.22 |
| The weight values vary widely for each measurement. | Is the floor surface is uneven? | p.22 | |
| The battery low indicator appears. | The battery power is low. | Replace all four “AA” batteries with new ones. | p.22 |
| The %Fat value displayed is abnormally high or low. | Refer to “Avoid Taking Measurements Under the Following Conditions” and “Cases When the Calculated Results May Differ from Actual Body Fat Percentages” on pages 16 to 17. | p.22 | |
| Other conditions. | Remove the batteries, then reinsert them after waiting for at least one minute. | p.22 |