2 TABLE OF CO NTENTS SECTION 1: MAIN TENANCE PROCEDURE ………………… 3 1. MAINTENANCE CHECK LIST………………………........ ......................4 2. TENSIONING THE BELT PROCEDU RE………………………….……..5-6 3. DECK RE-WAXING PROCEDURE………………………… ……….
3 SECTION 1 MAINTE NANCE P ROCED URE.
4 MAINTENANCE CHEC K LIST Clean Motor Clean (Vacu um) Control Board Inspect Running Belt Inspect & Re-waxi ng Deck R e-waxing Inspect Clean V Belt Inspect Running belt Tensio n Test Emerge ncy But.
5 TENSIONING T HE BELT PROCE DURE Caution: Over-tightening of the roller wi ll severely shorten the life of the belt and may cause further damage to other com ponents. Running Bel t: If when you plant your foot o n the belt, you can feel a slipping sensation then the belt has stretched and is sli pping across the rollers.
6 Drive Bel t: If you have tensioned the running belt and are still experiencing a slipping, adjust the tension screw. Then try the treadmill again to check for slipping.
7 DECK RE-WAXI NG PROCEDURE Frequency : Eve ry 1 mon th Parts name: Silicon oil set Parts number: SZTM74SOS Price (USD): 0.6 Use time : 1 Procedur e: 1. Loosen the tension bolts at both ends. 2. Pull the belt with your left hand and apply the silicon in the deck with your right hand.
8 CLEAN THE GRO OVES PROCE DURE Frequency : Ever y 3 months Procedur e: 1.Remove the drive belt and check the grooves in belt for dirt or dust and clean it. 3.Check the grooves in roller pulley for dirt or dust and clean it. If dirty grooves in the drive belt, m otor and roller pulley , there will be noises while running.
9 SECTION 2 WIRING DIAG RAM INS TRUC TION.
10 T9800(TM87) MCB WIR ING (FOR 110V / 220V) P7 P1 P6 J1 P4 J2 P3 P7----- --Motor wire P6----- - on/off switc h (power) J2------ -Console cable P1----- --Fan power P2--------SAF E .
11 T9800(TM87) MCB WIR ING DEFINITION OF PIN JP1:Elevation cable (6pin/AMP-3 50762-4) Incline motor does turn on power COM 6 Incline motor does move to down DOWN 5 Incline motor does move to up UP 4 I.
12 J2: console cable 1 2 19 20 ERR. SIG. 19 Definition Pin Console ground 20 RX IN(RESERVE) 18 RESERVE 17 TX OUT(RESERVE) 16 E_STOP 15 Console provide for in cline mo tor DOWN signal 14 Console provid.
13 T9800(TM87) CONSOLE WIRING J15 J13------- Safety Pul l Switch J11------- Safety Push S witch J5------ ---Main HR Interface J14-------C onsole cable J15-------CSAF E 1 (Full csaf.
14 T8900(TM87) CONSOLE WIRING DEFI NITION OF PIN J14:20-pin co nsole cable 1 2 20 19 J14 ERR. SIG. 19 Definition Pin Console ground 20 RX IN(RESERVE) 18 RESERVE 17 TX OUT(RESERVE) 16 E_STOP 15 Console.
15 Definition Name Pin Console ground SS IN 2 Safe ke y SS OUT 1 J11: Safety Push Switch J13: Safety Pull Switch J13 J11 1 2 1 2 Definition Name Pin Console ground SS IN 2 Safe ke y SS OUT 1 J5: Mai n.
16 T9800(TM87) Electrical block diagram for 110V.
17 T9800(TM87) WIRING DIAG RAM INSTRUCT ION for 110V.
18 T9800(TM87) Electrical block diagram for 220V.
19 T9800(TM87) WIRING DIAG RAM INSTRUCT ION for 220V.
20 SECTION 3 CONSOLE FUNCTIO NAL FLOW DIAGR AM.
21 OPERATI NG T9800.
22 To Store up the param eter SELECT Decrease this show parameter of speed SLOW Add this show parameter of speed FAST To scroll through the list of set ting DOWN To scroll through the list of set ting UP KEY BEHALE FUNCTION T9800 OP ERATION MANUAL- E ngineer mode 1.
23 SOFTWARE VERSION EXIT MAINTENANCE MANUAL CALIBRATION AUTO-CALIBRATIO N SYSTEM TEST S CONFIGURATION Engineering Mod e Menu 99 15 40 P27 DEF AULT AGE 10:00 0:05 0: 20 P23 P AUSE TIME 99 5 30 P22 DEF AULT TIME English/Met ric P24 UN ITS CONFIGURATIO N Exits mode EXIT Reset Novra m ON P14 ELEVATION ERRS—OFF 12.
24 67.8 P20 EFF DIAMETER 48 1 26 P19 MAGNET COUNT YES P13 ELV DIRECTION 71 27 40 Value at zero or minimu m elevation P4 ELEVATION MIN MANU AL CALIB RATIO N Exits mode EXIT 40 12 30 P29 RAMP TIME ~ 1 30 P21 PWM START SPD 228 71 218 Value at maximu m elevation P5 ELEVATION MAX 486 249 341 P WM value a t max speed (12.
25 ELEVATION BURN-IN TEST BURN-IN TEST EXIT IO TEST SAFETY SWITCH TEST KEYBOARD TEST DISPLAY TEST HARDWARE TEST SYSTEM TESTS 67.8 3 41 P20 EFF DIAMETER 48 1 26 P19 M AGNET COUNT YES P13 ELV DIRECTION .
26 0 E RROR LOG 0 T READMILL MSG 0 P17 CLEAN 0 P26 LI FT MOTOR HOURS MAINTE NANC E Exits mode EXIT OFF P16 LUBRICATE DECK MSG 0 P25 BELT/MO TOR HOURS 65335 0 0 P10 TOT AL DISTANCE 6533.
27 SECTION 4 MCB LED I NST RUCTI ON S.
28 A C F A N.
29 Indicates if Console is commanding speed. LED 11 PWM Indicates the motor is moving via the encoder's feedback by blinking. LED 12 SPEED Indicates if the upper console is commanding Elevation UP. LED 10 UP Indicates if the upper console is commanding Elevation DOWN.
30 SECTION 5 TROUBL ESHO OTI NGS.
31 T9800 Console Er ror cod e NOVRAM failure E19 Safety Switch T est Failur e E18 Stuck ke y error E16 Speed Range (usu all y ca used by calibr ation) E9 Speed stall ( could be miss ing speed sensor) .
32 E1 - Reverse Elevation Pot Error 1 Enter engin eer mode o f “MANUAL CALIBRATION” screen Check the “P13 ELV DIRECTION” scre en whether set to “Yes” Set to “Yes” AUTO- Calibration Ent.
33 E2 – Elevation Out Of Range Error 2 Step 1. Calibrate Elevation Calibrate the elevation as outlined in the Sy ste m Calibr ation Procedure in below step. Step 2. CORRECTIVE ACTION 1.Check the failed system with a known good console cable. If fixed then repair/replace the console cable.
34 E3 – Elevation Stall N Y N N Y Y E3 Err or Enter Ha rdwa re T est Scree n Run Elevatio n Up And Down Trea dmill moves up or do wn ? Waiting the Elevation Motor to cool Position Feedb ack P roblem Motor Overhe ated? Motor Movement Iss ue Feedbac k Changes Elevation AUT O-Calibration Step 1 .
35 E5 – Ov er-s peed Error Step 1. AUTO CALIBRATION AUTO-Calibration the as outlined in the S ystem Calibration Procedure in below step. OVERVIEW If the actual speed from the speed sen sor exceeds the system maximum speed by a limit (currently 2 MPH) an over-speed error occurs (E5).
36 E6 – Runa way Belt Error OVERVIEW If the actual belt speed is greater than the target speed by a limit and increasing then an E6 error is called. E6 errors fla g errors that will result in the belt “ running away” or not responding to input.
37 E7 – Spee d Stall Error OVERVIEW If no belt movement is detected several se conds af ter commanding belt movement a speed stall error ( E7) is called.
38 E9 – Spee d Range Error OVERVIEW During nor mal ru n time operatio n the value st ored du ring auto cal ibra tion is used to init ially set the speed (e.
39 Speed Feedb ack Issues – See speed feedba ck issue trouble shoo ting sectio n in the CORRECT IVE ACTIO N PROC EDUR ES – Spe ed Issues section of this document. Speed Contr ol Issues – See s peed control iss ue trouble shoo ting gui de in the COR RECT IVE ACTION P ROCED URES – Spee d Issues section of this docu ment.
40 CORRECTIVE ACTION PROCEDURE S – Speed Issues Speed Feedback Issue Enter Magnet Count screen Magnet coun t = treadmill # of magnets Adjust magnet count to match number of magnets Re-run test Manua.
41 Belt Drive Issue Start PWM max test (firmware setu p screens), wait 20 seconds Perform steps in order listed until problem resolved. 1. .Replace ribbon cable with known good ribbon cable. 2. .Replace interface P CB with known good interface PCB. 3.
42 Speed Control I ssue Start PWM m ax test (firm ware setup scre ens), wait 20 seconds or unt il speed stabi lizes N Y Problem F ixed Run Auto Calibrat ion (fi rmware setup ) N Y OK Measure speed and compare t o value disp layed in time window Speed feedback i ssue Perform steps in order l isted un til prob lem resolved.
43 Speed Calibrat ion Issue Run auto cal ibration ( firmware s etup screen) N Y Auto calibra tion passed Done Start PWM m ax test (firm ware setup scre en), wait minim um 20 second s or unti l sped st.
44 E19 – NOVRA M Fail ure OVERVIE W If the value s stored in n on-volat ile memor y are ou t of li mits or do not match the saf ety check value stored in non-vol atile memo ry a NOVRA M failure occ urs.
An important point after buying a device Miele T9800HRT (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Miele T9800HRT yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Miele T9800HRT - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Miele T9800HRT you will learn all the available features of the product, as well as information on its operation. The information that you get Miele T9800HRT will certainly help you make a decision on the purchase.
If you already are a holder of Miele T9800HRT, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Miele T9800HRT.
However, one of the most important roles played by the user manual is to help in solving problems with Miele T9800HRT. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Miele T9800HRT along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center