Table of Contents 8 sections LED Display Field · LAB48 · Description · Specifi cations · … ShowHide
Page 1 of the LST LAB48 user manual — Specifi cations
Page 1 · click to enlarge
Page 1
LST LAB48 — LED Display Field diagram (page 1)
Fig. 1 · LED Display Field

LED Display Field

LST LAB48 — LED Display Field diagram (page 1)
Fig. 2 · LED Display Field
LST LAB48 — LED Display Field diagram (page 1)
Fig. 3 · LED Display Field
LST LAB48 — LED Display Field diagram (page 1)
Fig. 4 · LED Display Field

LAB48

LST LAB48 — LAB48 diagram (page 1)
Fig. 5
  • 48 freely programmable LED pairs
  • Indication of events and conditions of fi re detection control panels Series BC216 or BC016
  • Installation in control panels Series BC216 or LED Display Tableau LAT288
  • Different LED colors available
  • Individual labeling by means of inserted text labeling strips
LST LAB48 — LAB48 diagram (page 1)
Fig. 6

Description

The LED Display Field LAB48 serves for the indication of the events of detectors, detector zones, actuations, transmitting devices, or alarming devices on fi re detec- tion control panels Series BC216 or BC016 as well as the events of fl ooding zones or extinguishing systems on extinguishing control panels Series LC216.

48 LED pairs are arranged in two rows on the com- ponentry. Each LED pair can be freely assigned to the individual events. The left LEDs are intended for dis- playing the alarm or the activation, or for displaying a system condition, respectively. The right LEDs indicate the disablement or the fault condition of the assigned system component. The LED Display Field is available in multiple versions with different LED colors for varying applications.

  • The LED Display Field is designed to be installed into fi re detection control panels Series BC216 or into the LED Display Tableau LAT288:
  • The LAB48 can be mounted into a fi re detection control panel Series BC216 with display and operating fi eld, to which it is directly connected.
  • The LED Display Tableau LAT288 can accommodate up to 3 LED Display Fields LAB48 and the Remote Tableau Drive Unit PTU288-1. Due to the actuation via the INFO bus, the LED Display Tableau is a universal remote tableau for all fi re detection control panels Series BC216 and BC016 as well as the extinguishing control panel Series LC216.

Each LED pair can be individually labeled by means of labeling strips which are inserted into the front foil of the case cover.

The componentry is shipped with the necessary ac- cessory for trouble-free mounting on the case cover of the fi re detection control panel or in the LED Display Tableau.

LST LAB48 — Description diagram (page 1)
Fig. 7 · Description

Specifi cations

Current consumption at 24V typ. 2mA no active LED, +0.25mA per LED

Ambient temperature -20°C to +60°C

Dimensions L × W × H 176 × 120 × 15 (mm)

LAB48_DBL_LST_EN_0804.PDF • PAGE 1 A Building Safety. Building Security.

  • © LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH
  • A-1231 WIEN
  • WIEGELESTRASSE 36
  • TEL +43 1 52114-0
  • FAX +43 1 52114-27 [email protected]
  • <a href="http://WWW.LST.AT" rel="nofollow noopener" target="_blank">WWW.LST.AT</a>
  • ALL RIGHTS RESERVED

Weight 60g

Page 2 of the LST LAB48 user manual — LAB48-4
Page 2 · click to enlarge
Page 2

LAB48-1

48 LEDs alarm/release/activation red

48 LEDs disablement/fault yellow

Part No. 214024

Order name LED-Display Field LAB48-1

LAB48-2

48 LEDs alarm/release/activation yellow

48 LEDs disablement/fault yellow

Part No. 214030

Order name LED-Display Field LAB48-2

LAB48-3

24 LEDs alarm/release/activation (left side) red

24 LEDs alarm/release/activation (right side) yellow

48 LEDs disablement/fault yellow

Part No. 214032

Order name LED-Display Field LAB48-3

LAB48-4

24 LEDs alarm/release (left side) red

24 LEDs activation (right side) green

24 LEDs disablement/fault (left side) yellow

24 LEDs disablement/fault (right side) yellow

Part No. 214036

Order name LED-Display Field LAB48-4

LAB48_DBL_LST_EN_0804.PDF • PAGE 2 A Building Safety. Building Security.

  • © LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH
  • A-1231 WIEN
  • WIEGELESTRASSE 36
  • TEL +43 1 52114-0
  • FAX +43 1 52114-27 [email protected]
  • <a href="http://WWW.LST.AT" rel="nofollow noopener" target="_blank">WWW.LST.AT</a>
  • ALL RIGHTS RESERVED
Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the LST LAB48

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the LST LAB48

Be the first to ask — other owners or our team will answer.

Original document

LST LAB48 manual PDF

2 pages·111 KB·Smoke Alarm·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…