EN
Official user manual

LST ECO1002

1 pages·94 KB·Smoke Alarm·PDF·ENDEFRITNLJA
LST ECO1002
Table of Contents 4 sections Optical-Thermal Detector · ECO1002 · Description · Specifi cations ShowHide
Page 1 of the LST ECO1002 user manual — Specifi cations
Page 1 · click to enlarge
Page 1
LST ECO1002 — Optical-Thermal Detector diagram (page 1)
Fig. 1 · Optical-Thermal Detector

Optical-Thermal Detector

LST ECO1002 — Optical-Thermal Detector diagram (page 1)
Fig. 2 · Optical-Thermal Detector
LST ECO1002 — Optical-Thermal Detector diagram (page 1)
Fig. 3 · Optical-Thermal Detector
LST ECO1002 — Optical-Thermal Detector diagram (page 1)
Fig. 4 · Optical-Thermal Detector

ECO1002

  • Addressable conventional technology
LST ECO1002 — ECO1002 diagram (page 1)
Fig. 5
  • Combination of optical and thermal characteristics of fi re
  • Drift compensation
  • Individual detector addressing by means of optional address module
  • Optional connection of remote indicator
  • Function testable with Remote Test Unit ECO1000RTU
LST ECO1002 — ECO1002 diagram (page 1)
Fig. 6

Description

The Optical-Thermal Detector ECO1002 uses both the scattered light principle as well as a separate thermal detection unit. It was developed to detect the charac- teristics of fi re in a wide range of applications, and to avoid deceptive alarms. The modern design of both measurement systems and the analysis of the parame- ters by means of a special algorithm allow to reliably evaluate the characteristics of fi re. This makes it an all-rounder that is used in virtually all fi elds of fi re de- tection. An internal drift compensation adjusts the alarm thres- hold by continually evaluating the contamination of the

detector. With that, the sensitivity of the detector is kept constant for a long time.

Addressable conventional technology is used for alarm transmission to the fi re detection control panel. By means of the Address Module NG58-1, each detector can be addressed individually.

A test activation of the detector can be carried out using the Remote Test Unit ECO1000RTU. The detec- tor can be attached to various detector bases and it can be protected against theft.

LST ECO1002 — Description diagram (page 1)
Fig. 7 · Description

Specifi cations

Operating voltage Supply through the detector line voltage

Current consumption typ. 80µA (quiescent)

Alarm temperature 58°C (maximum-heat component)

Operating temperature max. +45°C

Ambient temperature -30°C to +70°C

Relative humidity 5 – 95% (no condensation)

Dimensions ø × H 102 × 40.5 (mm)

Order name Optical-Thermal Detector/Conv./1000/SS ECO1002

ECO1002_DBL_LST_EN_0804.PDF • PAGE 1 A Building Safety. Building Security.

  • © LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH
  • A-1231 WIEN
  • WIEGELESTRASSE 36
  • TEL +43 1 52114-0
  • FAX +43 1 52114-27 [email protected]
  • <a href="http://WWW.LST.AT" rel="nofollow noopener" target="_blank">WWW.LST.AT</a>
  • ALL RIGHTS RESERVED
Show 4 more labels / short text on this page
Colour white · Weight 75g · Approval VdS G201067 · Order number 241046
Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the LST ECO1002

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the LST ECO1002

Be the first to ask — other owners or our team will answer.

Original document

LST ECO1002 manual PDF

1 pages·94 KB·Smoke Alarm·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…