EN
Linear logo
Official user manual

Linear DMC-10RS

22 pages·1.4 MB·Intercom System·PDF·ENDEFRITNLJA
Linear DMC-10RS
Table of Contents 80 sections DMC-10 · Structured Wire Intercom System · Installation and Operation Instructions · Introduction · … ShowHide
DMC-10p.1Structured Wire Intercom Systemp.1Installation and Operation Instructionsp.1Introductionp.3Safety Information and Cautionsp.4Explanation of Graphic Warning Symbolsp.4CAUTIONp.4RISK OF ELECTRIC SHOCKp.4DO NOT OPENp.4CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCKp.4DO NOT REMOVE COVER (OR BACK)p.4NO USER-SERVICEABLE PARTS INSIDEp.4REFER SERVICE TO QUALIFIED PERSONNELp.4General Wiring Cautionsp.4Intercom Room Station Cautionsp.4Safety Information and Cautions (Continued)p.5Important Safety Notesp.5Component Featuresp.6Installationp.7Installation (Continued)p.8SWITCH NUMBERS 1-8 MATCH THE STATION NUMBERS 1-8p.11MUTE SWITCHp.11O Np.11F Fp.11DOOR RELEASE SWITCHp.11General Operationp.12General Operation (Continued)p.13Constant Modesp.16Constant Modes (Continued)p.17Troubleshootingp.18SYMPTOM CAUSE SOLUTIONp.18Check power supply input & output voltagep.18No hub status indicators lit No power to hubp.18Hub station status indicator not lit on an installed stationp.18Check Cat-5 wiring, redo wiring if necessaryp.18Wiring errorp.18Expansion hub status indicator not lit (with expansion hub installed)p.18Wiring error or no power to expansion hubp.18Hum or buzz in audio Electrical interferencep.18Wire door station to a different hub connector for the correct chimep.18Door station sounds wrong chimep.18Door station wired to wrong hub connectorp.18Stations came out of constant modesp.18Power interruption at hubp.18Reset stations into constant modesp.18Station will not go into Privacy Mute Modep.18Set hub mute dipswitch for station to ONp.18Hub mute dipswitch for station set to OFFp.18Station will not go into Do-not-disturb Modep.18Hub door release dipswitch for station set to OFFp.18Set hub door release dipswitch for station to ONp.18Station will not activate door releasep.18Station to monitor set to Privacy Mute Mode or Do-not-disturb Modep.18Cannot monitor a station in Listen Modep.18Low or no intercom volumep.18Station’s volume control set low or offp.18Reset station’s volume controlp.18System Setup and Option Logp.19STATION NUMBER TYPE LOCATION DIPSWITCH OPTIONSp.191 ❑ ROOM STATION ❑ PATIO STATION ❑ DOOR STATIONp.192 ❑ ROOM STATION ❑ PATIO STATION ❑ DOOR STATIONp.193 ❑ ROOM STATION ❑ PATIO STATION ❑ DOOR STATIONp.194 ❑ ROOM STATION ❑ PATIO STATION ❑ DOOR STATIONp.195 ❑ ROOM STATION ❑ PATIO STATION ❑ DOOR STATIONp.196 ❑ ROOM STATION ❑ PATIO STATION ❑ DOOR STATIONp.197 ❑ ROOM STATION ❑ PATIO STATION ❑ DOOR STATIONp.198 ❑ ROOM STATION ❑ PATIO STATION ❑ DOOR STATIONp.19Intercom Accessories & Kitsp.20DMC-10 Intercom Kitsp.20Model DMC-10Kitp.20DMC-10 Intercom Accessoriesp.20Model DMC-10AWPp.20Contains one audio input wall plate Model DMC-10Hp.20Contains one intercom system hub and power supply Model DMC-10RSp.20Contains one room station with white faceplate Model DMC-10PSp.20Contains one patio station with white faceplate Model DMC-10DSp.20DMC-10 Custom Station Faceplatesp.20Model DMC-10RFW-4p.20Contains four white room station faceplates Model DMC-10RFB-4p.20Contains four black room station faceplates Model DMC-10RFA-4p.20
Page 1 of the Linear DMC-10RS user manual — Installation and Operation Instructions
Page 1 · click to enlarge
Page 1
Linear DMC-10RS — DMC-10 diagram (page 1)
Fig. 1

DMC-10

Linear DMC-10RS — DMC-10 diagram (page 1)
Fig. 2

Structured Wire Intercom System

Installation and Operation Instructions

Linear DMC-10RS — Installation and Operation Instructions diagram (page 1)
Fig. 3 · Installation and Operation Instructions
Linear DMC-10RS — Installation and Operation Instructions diagram (page 1)
Fig. 4 · Installation and Operation Instructions
Linear DMC-10RS — Installation and Operation Instructions diagram (page 1)
Fig. 5 · Installation and Operation Instructions

(760) 438-7000 USA & Canada (800) 421-1587 & (800) 392-0123

Toll Free FAX (800) 468-1340

www.linearcorp.com www.mssystems.com

Show 4 more labels / short text on this page
DMC-10H Intercom Hub · DMC-10RS Room Station · DMC-10PS Patio Station · DMC-10DS Door Station
Page 2 of the Linear DMC-10RS user manual — DMC-10
Page 2 · click to enlarge
Page 2
Page 2 of the Linear DMC-10RS user manual — DMC-10
Page 3 of the Linear DMC-10RS user manual — Introduction
Page 3 · click to enlarge
Page 3

Introduction

Linear’s M&S Systems brand Model DMC-10 Structured Wiring Intercom System offers several advanced features never before available in an intercom system. Its distributed hub design provides easy installation and structured wiring mounting compatibility necessary for modern residential and light commercial applications.

The room, door, and patio stations showcase a new, contemporary design, crafted to blend smoothly into the installation’s decor. Station faceplates are available in a variety of colors to further customize each installation. Room station keypads are illuminated with soft blue indicators while the intercom is in use. The door and patio station keys are illuminated with white lighting for easy nighttime operation.

The heart of the system is the Model DMC-10H Intercom Hub. The intercom hub grid mounts in a structured wiring enclosure. Up to eight room, door, and patio stations in any combination can be connected to the system hub using up to 500 feet of standard Cat-5 cable for each station. For larger installations, a second system hub can be added for expansion, providing a total system capacity of up to 16 stations. The Model DMC-10AWP Audio Input Wall Plate can be added to the system to connect an external audio source for distribution throughout the intercom system.

The room, patio, and door stations mount inside standard 2-gang junction boxes and are easy to install and wire. Each station and the system hub contains color-coded Type 110 punch-down terminal blocks for fast and reliable connection to Cat-5 cable. A 12-volt switching power supply is included with each intercom hub.

Linear DMC-10RS — Introduction diagram (page 3)
Fig. 6 · Introduction

Figure 1. Typical DMC-10 Installation

Page 4 of the Linear DMC-10RS user manual — Intercom Room Station Cautions
Page 4 · click to enlarge
Page 4

Safety Information and Cautions

Explanation of Graphic Warning Symbols

This symbol is intended to alert the user to the presence of un-insulated “dangerous voltage” within the product’s enclosure that may be of suffi cient magnitude to constitute a risk of electric shock.

This symbol is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the device.

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK

DO NOT REMOVE COVER (OR BACK)

NO USER-SERVICEABLE PARTS INSIDE

REFER SERVICE TO QUALIFIED PERSONNEL

General Wiring Cautions

DO NOT USE EXCESSIVE FORCE ON PUNCH-DOWN TERMINALS! IF USING AN IMPACT TYPE 110 PUNCH-DOWN TOOL, SET THE FORCE ADJUSTMENT TO “LOW” BEFORE TERMINATING CAT-5 CABLES.

The 120 VAC line to the structured wiring enclosure’s junction box must be run by a licensed electrician.

Individual CAT-5 cable runs from the hub to any station or audio input wall plate should not exceed 500 feet.

Label all cables for identifi cation at the intercom hub.

DO NOT SPLICE CABLES! Splices are unreliable and defeat the signal isolation properties of the cable.

DO NOT STAPLE CABLES! Staples cause shorts.

DO NOT RUN 120 VAC ELECTRICAL WIRES INSIDE INTERCOM STATION JUNCTION BOXES. If you encounter 120 VAC wires running through station junction boxes, you must have a qualifi ed electrician rerun those wires around the junction box.

KEEP CABLES AT LEAST 18 INCHES FROM FLORESCENT LIGHT FIXTURES, DIMMER CONTROLS, AND ALL OTHER WIRING. This includes AC wiring, security cable, cordless phone units, and other control wires. These can cause a “hum” or “buzzing” sound.

Keep all cables away from objects such as heating and air conditioning ducts, metal construction plates, and anything else with sharp edges that can damage cables.

Intercom Room Station Cautions

DO NOT install room stations in saunas. They will not withstand the extreme heat or moisture.

DO NOT install room stations within 10 feet of other room stations, in the same stud cavity as other room stations, or facing each other. This will cause acoustic feedback.

Show 11 more labels / short text on this page
• · • · • · • · • · • · • · • · • · • · •
Page 5 of the Linear DMC-10RS user manual — Important Safety Notes
Page 5 · click to enlarge
Page 5

Safety Information and Cautions (Continued)

Important Safety Notes

POWER SOURCE This unit should only be connected to a 110-120 VAC power source as marked on the unit.

GROUNDING OR POLARIZATION Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fi t into your outlet, consult an electrician for replacement of the obsolete outlet.

NON-USE PERIODS Always turn the unit off and unplug when it is not being used or left unattended for long periods of time.

OBJECT AND LIQUID ENTRY Never push objects of any kind into the unit through the cabinet slots as they may touch dangerous voltage points or short out parts that could result in a fi re or electric shock. Never spill liquid of any kind on the unit.

CLEANING Unplug the unit from the wall outlet before cleaning or polishing it. Do not use liquid cleaners, aerosol cleaners, gasoline or other fl ammable fl uid. Clean the exterior of the unit with a slightly damp cloth.

WATER AND MOISTURE Do not use power line operated units near water - for example, near a bathtub, washbowl, kitchen sink, or laundry tub, in a wet basement, or near a swimming pool.

VENTILATION The appliance should be situated so that its location or position does not interfere with its proper ventilation. For example, the unit should not be situated on a bed, sofa, rug or placed in a built-in installation that may block the fl ow of air through the ventilation openings.

POWER CORD PROTECTION Power supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them paying particular attention to cords at plugs, convenience receptacles, and the point where they exit from the appliance.

READ INSTRUCTIONS All the safety and operating instructions should be read before the product is operated.

RETAIN INSTRUCTIONS The safety and operating instructions should be retained for future reference.

HEED WARNINGS All warnings on the product and in the operating instructions should be adhered to.

FOLLOW INSTRUCTIONS All operating and use instructions should be followed.

ATTACHMENTS Do not use attachments not recommended by the product manufacturer as they may cause hazards.

ACCESSORIES Do not place this product on an unstable cart, stand, tripod, bracket, or table. The product may fall, causing serious injury to a child or adult, and serious damage to the product. Use only with a cart, stand, tripod, bracket or table recommended by the manufacturer, or sold with the product. Any mounting of the product should follow the manufacturer’s instructions, and should use a mounting accessory recommended by the manufacturer.

OVERLOADING Do not overload wall outlets, extension cords, or integral convenience receptacles as this can result in a risk of fi re or electric shock.

REPLACEMENT PARTS When replacement parts are required, be sure the service technician has used replacement parts specifi ed by the manufacturer or have the same characteristics as the original part. Unauthorized substitutions may result in fi re, electric shock, or other hazards.

SAFETY CHECK Upon completion of any service or repairs to this product, ask the service technician to perform safety checks to determine that the product is in proper operating condition.

WALL OR CEILING MOUNTING The product should be mounted to a wall or ceiling only as recommended by the manufacturer.

HEAT The product should be situated away from heat sources such as radiators, heat registers, stoves, or other products (including amplifi ers) that produce heat.

Page 6 of the Linear DMC-10RS user manual — Component Features
Page 6 · click to enlarge
Page 6

Component Features

Linear DMC-10RS — Component Features diagram (page 6)
Fig. 7 · Component Features

Figure 2. Station and Hub Features

Page 7 of the Linear DMC-10RS user manual — Installation
Page 7 · click to enlarge
Page 7

Installation

System Design Evaluate the installation to determine locations for mounting the intercom components. The intercom hub mounts in a new or existing structured wiring enclosure. The DMC-10RS room stations can be located in any rooms that require communications. DMC-10PS patio stations are weather resistant and designed to be mounted in protected areas outdoors. DMC-10DS door stations are also weather resistant and typically mounted next to the primary visitor entrance and any other auxiliary entrances. Up to eight stations of any type can be connected to one DMC-10H hub. An additional DMC-10H hub can be connected to the primary hub for expansion, increasing the system capacity to sixteen stations total.

Linear DMC-10RS — Installation diagram (page 7)
Fig. 8 · Installation

Structured Wiring Enclosure Linear’s OpenHouse brand Model H312KIT 12-inch high structured wiring enclosure is recommended for mounting the DMC-10H hub. Other OpenHouse enclosures can also be used to mount the hub. Enclosures mount recessed, between wall studs, or can be surface mounted. Be sure the enclosure is in a location where 117 VAC power can be routed to the enclosure by a licensed electrical contractor for connection to an outlet in the enclosure.

Figure 3. OpenHouse Model H312KIT

Linear DMC-10RS — Installation diagram (page 7)
Fig. 9 · Installation

Hub Mounting The hub locks into the mounting grid of the structured wiring enclosure the same as other structured wiring modules (see Figure 4). Hook the mounting tabs into the grid, swing the hub into place, and push the locking button to fi nish the hub mounting.

Figure 4. Hub Mounting in the Enclosure

Structured Wiring Enclosure

Page 8 of the Linear DMC-10RS user manual — Installation (Continued)
Page 8 · click to enlarge
Page 8

Installation (Continued)

Linear DMC-10RS — Installation (Continued) diagram (page 8)
Fig. 10 · Installation (Continued)

Junction Box Installation Each intercom station mounts inside a standard 2-gang J-box. Mount the J-boxes fl ush with the drywall at locations and heights convenient for the installation.

System Wiring Route Cat-5 or Cat-5e cable from each station’s J-box to the structured wiring enclosure where the hub will be mounted. Drill through studs and headers to accommodate cabling. Secure the cables with zip-tie straps (be careful not to puncture or pinch cables with staples). Route all cables 18” away from AC wiring and lamp dimmers. Route the cables from the stations into the enclosure through the wiring knockouts. Label each cable’s station location at the enclosure end.

Figure 5. Junction Box Installation

Linear DMC-10RS — Installation (Continued) diagram (page 8)
Fig. 11 · Installation (Continued)
MAXIMUM WIRE RUN500 FEET OF CAT-5 CABLE FROM EACH STATION TO THE ENCLOSURE

Station Installation Remove the faceplate from the station by twisting a screwdriver in the slot under the lower left corner of the faceplate. Use a Type 110 punch-down tool (if using an impact tool, set the tool to “low” force!) to connect the Cat-5 cable’s eight wires to the color coded connector on the back of each station. After wiring, install the station into the J-box, secure it with the four screws, and replace the faceplate. Note: Alternate color station faceplates are available (see Page 18).

Figure 6. Pre-wiring Cat-5 Cable

Linear DMC-10RS — Installation (Continued) diagram (page 8)
Fig. 12 · Installation (Continued)

1 TWIST SCREWDRIVER IN SLOT TO REMOVE FACEPLATE 2 USE TYPE 110 PUNCH DOWN TOOL TO CONNECT CABLE

Figure 7. Station Installation

Page 9 of the Linear DMC-10RS user manual — Installation (Continued)
Page 9 · click to enlarge
Page 9

Installation (Continued)

Linear DMC-10RS — Installation (Continued) diagram (page 9)
Fig. 13 · Installation (Continued)

Hub Wiring Use a Type 110 punch-down tool (if using an impact tool, set the tool to “low” force!) to connect the Cat-5 cable from each station to the color coded connectors on the hub.

Wire the door station(s) fi rst. The hub’s station location number determines the sound of the door station’s chime.

Hub station 1, 2, or 3 = ding-dong Hub station 4, 5, or 6 = dong-dong Hub station 7 or 8 = dong-ding

Figure 8. Door Station Chime Selection

Wire the remaining stations to the hub connectors. To document the installation, note the station type and locations in the log on Page 17.

Linear DMC-10RS — Installation (Continued) diagram (page 9)
Fig. 14 · Installation (Continued)

USE A TYPE 110 PUNCH-DOWN TOOL TO TERMINATE CAT-5 CABLES FROM STATIONS

BLUE STRIPE BLUE ORANGE STRIPE ORANGE GREEN STRIPE GREEN BROWN STRIPE BROWN

Figure 9. Hub Wiring

Optional Door Strike Installation The intercom hub features a normally open door release relay that can switch up to 3 amps @ 30 volts. The relay can be used to activate a Model DRW electric door strike. The relay is triggered by pressing the button on any room station. Note: The unlock feature can be disabled on any room station using the option switches on the hub.

Linear DMC-10RS — Installation (Continued) diagram (page 9)
Fig. 15 · Installation (Continued)

DMC-10H DOOR RELEASE RELAY 3 AMP LOAD MAXIMUM !

M&S SYSTEMS MODEL DRW 24 VAC ELECTRIC DOOR STRIKE

Figure 10. Electric Door Strike Wiring

Page 10 of the Linear DMC-10RS user manual — Installation (Continued)
Page 10 · click to enlarge
Page 10

Installation (Continued)

Optional Expansion Hub Installation To increase the system’s capacity, a second hub can be connected to the primary hub. The hubs connect to each other with up to 150 feet of Cat-5 cable. Each hub requires its own power supply.

Linear DMC-10RS — Installation (Continued) diagram (page 10)
Fig. 16 · Installation (Continued)

UP TO 150 FEET OF CAT-5 CABLE NOTE: WIRE PAIRS CHANGE

Mount the second hub in the enclosure (or in another enclosure). Connect the primary hub to the second hub using the connectors labeled EXPANSION. Note: Match the wire colors to the connector on the 1st hub, fl ip the wire pair order on the second hub (see Figure 11).

Figure 11. Expansion Hub Wiring

Connect up to eight additional stations to the expansion hub. Wiring is the same as the primary hub.

Optional Audio Input Wall Plate An external audio source can be connected to the system using the Model DMC-10AWP wall plate. The wall plate connects to one of the hub’s station connectors in place of a station. Room and patio stations set to Listen Mode can play the audio source. The audio source will be automatically muted when the intercom is in use.

Linear DMC-10RS — Installation (Continued) diagram (page 10)
Fig. 17 · Installation (Continued)

The audio input wall plate also features an input level control and a mute output. The mute output is a relay contact closure that can be used to silence an independent music system when the intercom is in use.

Figure 12. Audio Wall Plate Wiring

Page 11 of the Linear DMC-10RS user manual — DOOR RELEASE SWITCH
Page 11 · click to enlarge
Page 11

Installation (Continued)

Hub Options The intercom hub has two banks of dipswitches. One bank enables or disables each door station’s door release button. The other bank enables or disables each door or patio station’s privacy mute and do- not-disturb feature.

SWITCH NUMBERS 1-8 MATCH THE STATION NUMBERS 1-8

MUTE SWITCH

STATIONS WITH SWITCHES THAT ARE "ON" WILL BE ABLE TO USE PRIVACY MUTE MODE

O N

F F

O N

F F

Select the options appropriate for the installation. The numbers on the dipswitches correspond to the hub’s station numbers. Mark the switch settings in the log on Page 17.

DOOR RELEASE SWITCH

STATIONS WITH SWITCHES THAT ARE "ON" WILL BE ABLE TO ACTIVATE THE DOOR RELEASE RELAY

Figure 13. Hub Option Switches

Hub Power Supply Connection The switching power supply module included with each hub powers the hub and all stations connected to it. If an expansion hub is used, it requires its own power supply.

Linear DMC-10RS — DOOR RELEASE SWITCH diagram (page 11)
Fig. 18

PLUG POWER SUPPLY OUTPUT INTO THE INTERCOM HUB'S POWER CONNECTOR

Place the power supply in the enclosure with the hub. Insert the power supply output plug into the hub’s POWER jack. Insert the power supply’s power cord into the 117 VAC outlet installed in the enclosure.

Hub Status Indicators When the hub powers up, a diagnostic check is run for all the stations connected. On the hub, the green indicator above the station’s connector will light and stay lit for all stations that pass the diagnostic check (also for the optional expansion hub). If any hub indicators do not light, check the wiring associated with that connector.

Figure 14. Power Supply Connections

Linear DMC-10RS — DOOR RELEASE SWITCH diagram (page 11)
Fig. 19

EACH TIME POWER IS APPLIED TO THE HUB, THE HUB CHECKS THE STATUS OF ALL CONNECTED STATIONS

The diagnostic check only occurs when power is applied to the hub. To perform the diagnostic check at any time, cycle the hub power off then on again.

THE STATION STATUS INDICATORS WILL LIGHT FOR EACH STATION (AND EXPANSION HUB) THAT CHECKS OK

Figure 15. Hub Status Indicators

Page 12 of the Linear DMC-10RS user manual — General Operation
Page 12 · click to enlarge
Page 12

General Operation

Intercom Features Each room and patio station can be used for communication with other room, patio, or door stations. Also, room and patio stations feature four special constant modes for room monitoring and privacy.

If the optional audio input wall plate is installed, room and patio stations can be set to play to the audio source connected to the wall plate.

Volume Control Volume at each station can be set with its VOL button. Each momentary VOL↑ press increases, or VOL↓ press decreases, the station’s volume. Pressing and holding the VOL↓ button for one second will silence the station’s speaker. When the station’s volume is set all the way down, the VOL button will remain dimly lit. Pressing and holding the VOL↑ button for one second returns the volume to its previous level.

Linear DMC-10RS — General Operation diagram (page 12)
Fig. 20 · General Operation

PRESS AND HOLD VOL FOR ONE SECOND TO SILENCE THE STATION'S SPEAKER

PRESS AND HOLD VOL FOR ONE SECOND TO RETURN TO STATION'S LAST VOLUME SETTING

Figure 16. Volume Control

Linear DMC-10RS — General Operation diagram (page 12)
Fig. 21 · General Operation

AFTER RELEASING THE TALK BUTTON, THE ROOM STATION WILL LISTEN TO ALL OTHER ROOM AND PATIO STATIONS FOR 25 SECONDS

Hands-free Reply Room stations will automatically listen to all other room and patio stations for 25 seconds after the room station’s TALK button is released (except for stations in privacy mute or Do-not-disturb Mode). This allows for a “hands- free” reply from the person being called. This also applies when communicating with door stations using the room or patio station’s DOOR button.

OTHER STATIONS SET TO PRIVACY MUTE MODE OR DO-NOT-DISTURB MODE WILL NOT BE MONITORED

Figure 17. Hands-free Reply

Linear DMC-10RS — General Operation diagram (page 12)
Fig. 22 · General Operation

PRESS AND HOLD THE LISTEN BUTTON TO MONITOR ALL OTHER ROOM AND PATIO STATIONS WITHOUT MAKING A CALL

Quick Listen To momentarily listen to all of the room and patio stations without making a call, press and hold the room station’s LISTEN button. This mode WILL NOT listen to stations in Privacy Mute Mode or Do-not- disturb Mode.

OTHER STATIONS SET TO PRIVACY MUTE MODE OR DO-NOT-DISTURB MODE WILL NOT BE MONITORED

Figure 18. Quick Listen

Page 13 of the Linear DMC-10RS user manual — General Operation (Continued)
Page 13 · click to enlarge
Page 13

General Operation (Continued)

Door to Room and Door to Patio Communications When visitors arrive, they push a door station button to announce their arrival. Pressing the door station’s button sounds a chime on all stations (unless the station is set to Do-not-disturb Mode).

Door Button To communicate with the visitor at the door station, press and hold the room or patio station’s DOOR button while speaking. Release the DOOR button to listen to the visitor for 25 seconds. Press and hold the DOOR button again at any time to continue talking to the visitor, each time the DOOR button is released, the listening time will be extended another 25 seconds.

Linear DMC-10RS — General Operation (Continued) diagram (page 13)
Fig. 23 · General Operation (Continued)

PRESS AND HOLD THE DOOR BUTTON TO TALK TO A VISITOR AT THE DOOR STATION

RELEASE THE DOOR BUTTON TO LISTEN TO THE VISITOR AT THE DOOR STATION (LISTEN LASTS FOR 25 SECONDS)

Figure 19. Door Button

Linear DMC-10RS — General Operation (Continued) diagram (page 13)
Fig. 24 · General Operation (Continued)

Unlock Button If a door release has been installed, pressing the button on a room station will activate the door release for four seconds (if the door release feature is enabled for the station on the hub). The door release will stay activated as long as the button is held down.

PRESS THE UNLOCK BUTTON TO ACTIVATE THE DOOR RELEASE FOR FOUR SECONDS

THE DOOR RELEASE WILL STAY ACTIVATED FOR AS LONG AS THE UNLOCK BUTTON IS PRESSED

Figure 20. Unlock Button

Linear DMC-10RS — General Operation (Continued) diagram (page 13)
Fig. 25 · General Operation (Continued)

PRESSING THE MUTE BUTTON ANYTIME DURING LISTENING STOPS THE INTERCOM SESSION

Mute Button The communication session can be canceled at any time before the 25 second listening period expires by pressing the MUTE button.

Figure 21. Mute Button

Page 14 of the Linear DMC-10RS user manual — General Operation (Continued)
Page 14 · click to enlarge
Page 14

General Operation (Continued)

Room to Room and Room to Patio Communications A typical use for the system is to communicate between room stations throughout the installation and to patio stations.

Talk Button To communicate with other people at room or patio stations, press and hold the room station’s TALK button while speaking. Release the TALK button to listen to all other room and patio stations for 25 seconds (except stations in Privacy Mute or Do-not-disturb Modes). Press and hold the TALK button again at any time to continue talking, after the TALK button is released, the listening time will be extended another 25 seconds.

Linear DMC-10RS — General Operation (Continued) diagram (page 14)
Fig. 26 · General Operation (Continued)

PRESS AND HOLD THE TALK BUTTON WHILE SPEAKING TO THE OTHER STATIONS

RELEASE THE TALK BUTTON TO LISTEN TO THE OTHER STATIONS

Figure 22. Room Station Talk Button

Hands-free Reply Direction Either person can change the direction of the hands-free conversation by pressing and holding their TALK button while speaking. After any TALK button is released the other person will be able to reply hands-free during the 25 second listening period (except after a TALK button has been pressed on a patio station).

Linear DMC-10RS — General Operation (Continued) diagram (page 14)
Fig. 27 · General Operation (Continued)

AFTER RELEASING THE TALK BUTTON, THE ROOM STATION WILL LISTEN TO ALL OTHER ROOM AND PATIO STATIONS FOR 25 SECONDS

OTHER STATIONS SET TO PRIVACY MUTE MODE OR DO-NOT-DISTURB MODE WILL NOT BE MONITORED

Figure 23. Hands-free Reply

Mute Button To cancel the communication session at any time before the 25 second listening period expires, press the MUTE button.

Linear DMC-10RS — General Operation (Continued) diagram (page 14)
Fig. 28 · General Operation (Continued)

PRESSING THE MUTE BUTTON ANYTIME DURING LISTENING STOPS THE INTERCOM SESSION

Figure 24. Room Station Mute Button

Page 15 of the Linear DMC-10RS user manual — General Operation (Continued)
Page 15 · click to enlarge
Page 15

General Operation (Continued)

Patio to Room and Patio to Patio Communications A person at the patio station can make a call to the room stations, or another patio station. For security and privacy, the patio station will not trigger hands-free reply from room or other patio stations.

Talk Button To communicate with people inside, press and hold the patio station’s TALK button while speaking. Release the TALK button and wait for a reply from the inside stations. Press and hold the TALK button again at any time to repeat the call if it was unanswered.

Linear DMC-10RS — General Operation (Continued) diagram (page 15)
Fig. 29 · General Operation (Continued)

PRESS AND HOLD THE TALK BUTTON WHILE SPEAKING TO THE OTHER STATIONS

RELEASE THE TALK BUTTON AND LISTEN FOR ANOTHER STATION TO RETURN THE CALL

To ensure privacy, releasing the patio station’s TALK button WILL NOT cause automatic listening to the room stations for 25 seconds. The person at a room station (or another patio station) must always press TALK to respond to a patio station. When the room station’s TALK button is released, the room station will listen to the patio station and all other stations for 25 seconds (except stations in Privacy Mute or Do-not-disturb Mode). Each time the room station’s TALK button is released, the listening time will be extended another 25 seconds.

Figure 25. Patio Station Talk Button

Mute Button To cancel the communication session at any time before the 25 second listening period expires, press the MUTE button.

Linear DMC-10RS — General Operation (Continued) diagram (page 15)
Fig. 30 · General Operation (Continued)

PRESSING THE MUTE BUTTON ANYTIME DURING LISTENING STOPS THE INTERCOM SESSION

Figure 26. Patio Station Mute Button

Page 16 of the Linear DMC-10RS user manual — Constant Modes
Page 16 · click to enlarge
Page 16

Constant Modes

Four special constant modes are available for room stations and patio stations. Each room and patio station can be set to one of the four modes. Constant modes remain in effect, even after the intercom is used for other functions. The constant modes can be used to (1) prevent monitoring from other stations; (2) prevent monitoring and calling from other stations; (3) monitor sounds in other rooms or audio from an external source; or (4) select specifi c room stations or patio stations for constant monitoring.

Privacy Mute Mode For privacy, room and patio stations can be set to prevent monitoring from other stations (if the mute feature is enabled for the station on the hub).

Linear DMC-10RS — Constant Modes diagram (page 16)
Fig. 31 · Constant Modes

TO SELECT PRIVACY MUTE MODE FOR THE STATION, PRESS THE MUTE BUTTON WHILE THE STATION IS IDLE

WHEN THE STATION IS IN PRIVACY MUTE MODE, THE MUTE BUTTON WILL STAY LIT

To enter or exit Privacy Mute Mode, momentarily press the station’s MUTE button. In Privacy Mute Mode the station’s MUTE button lights.

OTHER STATIONS WILL NOT BE ABLE TO MONITOR THIS STATION WHEN IT IS IN PRIVACY MUTE MODE

TO EXIT PRIVACY MUTE MODE, PRESS THE MUTE BUTTON AGAIN

The station can still perform regular intercom communications while in Privacy Mute Mode.

Figure 27. Privacy Mute Mode

Do-not-disturb Mode For privacy and silence, room and patio stations can be set to prevent monitoring and calling from other stations (if the mute feature is enabled for the station on the hub).

Linear DMC-10RS — Constant Modes diagram (page 16)
Fig. 32 · Constant Modes

TO SELECT DO-NOT-DISTURB MODE FOR THE STATION, PRESS THE MUTE BUTTON FOR TWO SECONDS

WHEN THE STATION IS IN DO-NOT-DISTURB MODE, THE MUTE AND VOL BUTTONS WILL STAY LIT

To select Do-not-disturb Mode, press and hold the station’s MUTE button for two seconds. In Do-not-disturb Mode the station’s MUTE and VOL buttons light. To exit Do-not-disturb Mode, press the MUTE button.

OTHER STATIONS WILL NOT BE ABLE TO MONITOR OR CALL THIS STATION WHEN IT IS IN DO-NOT-DISTURB MODE

TO EXIT DO-NOT-DISTURB MODE, PRESS THE MUTE BUTTON AGAIN

The station can still perform regular intercom communications if the call is made from the station in Do-not-Disturb Mode.

Figure 28. Do-not-disturb Mode

Page 17 of the Linear DMC-10RS user manual — Constant Modes (Continued)
Page 17 · click to enlarge
Page 17

Constant Modes (Continued)

Monitor Mode Monitor Mode is typically used for monitoring a baby or other sounds in a room. When a room or patio station is set to Monitor Mode, the station’s microphone is always on. Set other stations to Listen Mode (see below) to hear sounds from any station(s) set to Monitor Mode.

Linear DMC-10RS — Constant Modes (Continued) diagram (page 17)
Fig. 33 · Constant Modes (Continued)

TO SELECT MONITOR MODE MODE FOR THE STATION, PRESS THE TALK AND MUTE BUTTONS TOGETHER

WHEN THE STATION IS IN MONITOR MODE, THE TALK BUTTON WILL STAY LIT

SET OTHER STATIONS TO LISTEN MODE TO HEAR SOUNDS FROM STATIONS IN MONITOR MODE

To enter or exit Monitor Mode, press the station’s MUTE and TALK buttons together. In Monitor Mode, the station’s TALK button lights.

TO EXIT MONITOR MODE, PRESS THE TALK AND MUTE BUTTONS TOGETHER

Figure 30. Monitor Mode

The station can still perform regular intercom communications while in Monitor Mode.

Listen Mode When a room or patio station is set to Listen Mode, the station’s speaker is always on. Set a station to Listen Mode to hear all stations set to Monitor Mode.

Linear DMC-10RS — Constant Modes (Continued) diagram (page 17)
Fig. 34 · Constant Modes (Continued)

TO SELECT LISTEN MODE FOR THE STATION, PRESS THE MUTE AND LISTEN BUTTONS TOGETHER

WHEN THE STATION IS IN LISTEN MODE, THE LISTEN BUTTON WILL STAY LIT

Also, if the optional audio input wall plate has been installed, set a station to Listen Mode to play the audio source connected to the wall plate.

SET OTHER STATIONS TO MONITOR MODE TO HEAR THEM USING LISTEN MODE

LISTEN MODE CAN ALSO BE USED TO PLAY AUDIO FROM THE AUDIO WALL PLATE

TO EXIT LISTEN MODE, PRESS THE MUTE AND LISTEN BUTTONS TOGETHER

To enter or exit Listen Mode, press the station’s MUTE and LISTEN buttons together. In Listen Mode, the station’s LISTEN button lights.

Figure 29. Listen Mode

The station can still perform regular intercom communications while in Listen Mode.

Page 18 of the Linear DMC-10RS user manual — Station to monitor set to Privacy Mute Mode or Do-not-disturb Mode
Page 18 · click to enlarge
Page 18

Troubleshooting

SYMPTOM CAUSE SOLUTION

Check power supply input & output voltage

No hub status indicators lit No power to hub

Hub station status indicator not lit on an installed station

Check Cat-5 wiring, redo wiring if necessary

Wiring error

Check Cat-5 wiring to expansion hub, redo wiring if necessary, check expansion hub power supply

Expansion hub status indicator not lit (with expansion hub installed)

Wiring error or no power to expansion hub

Check for station Cat-5 wiring near AC power wires or near lamp dimmers

Hum or buzz in audio Electrical interference

Wire door station to a different hub connector for the correct chime

Door station sounds wrong chime

Door station wired to wrong hub connector

Stations came out of constant modes

Power interruption at hub

Reset stations into constant modes

Station will not go into Privacy Mute Mode

Set hub mute dipswitch for station to ON

Hub mute dipswitch for station set to OFF

Station will not go into Do-not-disturb Mode

Set hub mute dipswitch for station to ON

Hub mute dipswitch for station set to OFF

Hub door release dipswitch for station set to OFF

Set hub door release dipswitch for station to ON

Station will not activate door release

Take station out of Privacy Mute Mode or Do-not-disturb Mode by pressing MUTE

Station to monitor set to Privacy Mute Mode or Do-not-disturb Mode

Cannot monitor a station in Listen Mode

Low or no intercom volume

Station’s volume control set low or off

Reset station’s volume control

Page 19 of the Linear DMC-10RS user manual — 8 ❑ ROOM STATION ❑ PATIO STATION ❑ DOOR STATION
Page 19 · click to enlarge
Page 19

System Setup and Option Log

STATION NUMBER TYPE LOCATION DIPSWITCH OPTIONS

1 ❑ ROOM STATION ❑ PATIO STATION ❑ DOOR STATION

MUTE ❑ OFF ❑ ON DOOR RELEASE ❑ OFF ❑ ON

2 ❑ ROOM STATION ❑ PATIO STATION ❑ DOOR STATION

MUTE ❑ OFF ❑ ON DOOR RELEASE ❑ OFF ❑ ON

3 ❑ ROOM STATION ❑ PATIO STATION ❑ DOOR STATION

MUTE ❑ OFF ❑ ON DOOR RELEASE ❑ OFF ❑ ON

4 ❑ ROOM STATION ❑ PATIO STATION ❑ DOOR STATION

MUTE ❑ OFF ❑ ON DOOR RELEASE ❑ OFF ❑ ON

5 ❑ ROOM STATION ❑ PATIO STATION ❑ DOOR STATION

MUTE ❑ OFF ❑ ON DOOR RELEASE ❑ OFF ❑ ON

6 ❑ ROOM STATION ❑ PATIO STATION ❑ DOOR STATION

MUTE ❑ OFF ❑ ON DOOR RELEASE ❑ OFF ❑ ON

7 ❑ ROOM STATION ❑ PATIO STATION ❑ DOOR STATION

MUTE ❑ OFF ❑ ON DOOR RELEASE ❑ OFF ❑ ON

8 ❑ ROOM STATION ❑ PATIO STATION ❑ DOOR STATION

MUTE ❑ OFF ❑ ON DOOR RELEASE ❑ OFF ❑ ON

❑ ROOM STATION ❑ PATIO STATION ❑ DOOR STATION

MUTE ❑ OFF ❑ ON DOOR RELEASE ❑ OFF ❑ ON

❑ ROOM STATION ❑ PATIO STATION ❑ DOOR STATION

MUTE ❑ OFF ❑ ON DOOR RELEASE ❑ OFF ❑ ON

❑ ROOM STATION ❑ PATIO STATION ❑ DOOR STATION

MUTE ❑ OFF ❑ ON DOOR RELEASE ❑ OFF ❑ ON

❑ ROOM STATION ❑ PATIO STATION ❑ DOOR STATION

MUTE ❑ OFF ❑ ON DOOR RELEASE ❑ OFF ❑ ON

❑ ROOM STATION ❑ PATIO STATION ❑ DOOR STATION

MUTE ❑ OFF ❑ ON DOOR RELEASE ❑ OFF ❑ ON

❑ ROOM STATION ❑ PATIO STATION ❑ DOOR STATION

MUTE ❑ OFF ❑ ON DOOR RELEASE ❑ OFF ❑ ON

❑ ROOM STATION ❑ PATIO STATION ❑ DOOR STATION

MUTE ❑ OFF ❑ ON DOOR RELEASE ❑ OFF ❑ ON

❑ ROOM STATION ❑ PATIO STATION ❑ DOOR STATION

MUTE ❑ OFF ❑ ON DOOR RELEASE ❑ OFF ❑ ON

Show 8 more labels / short text on this page
Expansion · Expansion · Expansion · Expansion · Expansion · Expansion · Expansion · Expansion
Page 20 of the Linear DMC-10RS user manual — DMC-10 Custom Station Faceplates
Page 20 · click to enlarge
Page 20

Intercom Accessories & Kits

DMC-10 Intercom Kits

Model DMC-10Kit

Contains four room stations with white faceplates, one door station with white faceplate, one system hub and power supply Model H312KIT

Contains one OpenHouse brand structured wire enclosure and cover

DMC-10 Intercom Accessories

Model DMC-10AWP

Contains one audio input wall plate Model DMC-10H

Contains one intercom system hub and power supply Model DMC-10RS

Contains one room station with white faceplate Model DMC-10PS

Contains one patio station with white faceplate Model DMC-10DS

Contains one door station with white faceplate

DMC-10 Custom Station Faceplates

Model DMC-10RFW-4

Contains four white room station faceplates Model DMC-10RFB-4

Contains four black room station faceplates Model DMC-10RFA-4

Contains four almond room station faceplates Model DMC-10PFW-4

Contains four white patio station faceplates Model DMC-10PFBB-4

Contains four bright brass patio station faceplates Model DMC-10PFAB-4

Contains four antique brass patio station faceplates Model DMC-10PFSN-4

Contains four satin nickel patio station faceplates Model DMC-10DFW-4

Contains four white door station faceplates Model DMC-10DFBB-4

Contains four bright brass door station faceplates Model DMC-10DFAB-4

Contains four antique brass door station faceplates Model DMC-10DFSN-4

Contains four satin nickel door station faceplates

Page 21 of the Linear DMC-10RS user manual — Limited Warranty
Page 21 · click to enlarge
Page 21

Limited Warranty

Linear LLC warrants its M&S Systems brand products to be free of defects for 2 years. The warranty period begins on either (a) the date of purchase or installation date of this product, or (b) the date of closing on a new residence in which this product was originally installed.

The warranty extends to the original user of the product and to each subsequent owner of the product during the term of the warranty. Linear will repair or replace, at its option, parts and materials at no charge. Parts supplied under this warranty may be new or rebuilt at the option of Linear.

If, during the warranty period, the product appears to have a defect, please call our toll free number (800-421-1587) prior to dismantling. Dismantling the product prior to calling our service number may void the warranty. Before returning any product to Linear, obtain a Return Product Authorization (RPA) number from our service department. Linear will return the repaired product freight prepaid within the continental United States. ANY PRODUCT RETURNED TO LINEAR WITHOUT AN RPA NUMBER WILL BE REFUSED.

This limited warranty is in lieu of any other warranties, express or implied, including any implied warranty of merchantability or fi tness for a particular purpose or otherwise, and of any other obligations or liability on the seller’s part. This limited warranty does not cover damage caused by improper installation, acts of God, criminal acts, the violation of applicable building or electrical codes or the use of non-M&S wire or cable (excluding CAT-5 and RG-6).

Under no circumstances shall Linear be liable for consequential, incidental or special damages arising in connection with use, or inability to use this product. In no event shall Linear’s liability hereunder exceed the cost of the product covered hereby. No person is authorized to assume for us or obligate us for any other liability in connection with the sale of this product. Some states do not allow the exclusion or limitation of consequential, incidental or special damages, so the above limitation or exclusion may not apply to you. This limited warranty gives you specifi c legal rights, and you may also have other rights, which vary from state to state.

FCC Notice This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Page 22 of the Linear DMC-10RS user manual — Intercom Accessories & Kits
Page 22 · click to enlarge
Page 22

Copyright © 2007 Linear LLC 227592 A

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Fix-it

Troubleshooting

Common problems, likely causes, and what to do.

ProblemPossible causeRemedy
No hub status indicators litNo power to hubCheck power supply input & output voltage p.18
Hub station status indicator not lit on an installed stationWiring errorCheck Cat-5 wiring, redo wiring if necessary p.18
Expansion hub status indicator not lit (with expansion hub installed)Wiring error or no power to expansion hubCheck Cat-5 wiring to expansion hub, redo wiring if necessary, check expansion hub power supply p.18
Hum or buzz in audioElectrical interferenceCheck for station Cat-5 wiring near AC power wires or near lamp dimmers p.18
Door station sounds wrong chimeDoor station wired to wrong hub connectorWire door station to a different hub connector for the correct chime p.18
Stations came out of constant modesPower interruption at hubReset stations into constant modes p.18
Station will not go into Privacy Mute ModeHub mute dipswitch for station set to OFFSet hub mute dipswitch for station to ON p.18
Station will not go into Do-not-disturb ModeHub mute dipswitch for station set to OFFSet hub mute dipswitch for station to ON p.18
Station will not activate door releaseHub door release dipswitch for station set to OFFSet hub door release dipswitch for station to ON p.18
Cannot monitor a station in Listen ModeStation to monitor set to Privacy Mute Mode or Do-not-disturb ModeTake station out of Privacy Mute Mode or Do-not-disturb Mode by pressing MUTE p.18
Low or no intercom volumeStation’s volume control set low or offReset station’s volume control p.18

Ask about the Linear DMC-10RS

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Linear DMC-10RS

Be the first to ask — other owners or our team will answer.

Original document

Linear DMC-10RS manual PDF

22 pages·1.4 MB·Intercom System·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…