EN
Linear logo
Official user manual

Linear Intercom Wall Plate (DMC-10AWP)

1 pages·436 KB·Intercom System·PDF·ENDEFRITNLJA
Linear Intercom Wall Plate (DMC-10AWP)
Table of Contents 48 sections PUNCH-DOWN TOOL · TO TERMINATE CAT-5 · CABLES FROM WALL · PLATE AND STATIONS · … ShowHide
Page 1 of the Linear Intercom Wall Plate (DMC-10AWP) user manual — TO ENCLOSURE
Page 1 · click to enlarge
Page 1

PUNCH-DOWN TOOL

TO TERMINATE CAT-5

CABLES FROM WALL

PLATE AND STATIONS

ORANGE STRIPE

BROWN STRIPE

BLUE STRIPE

GREEN STRIPE

USE A TYPE 110

ORANGE

GREEN

BROWN

BLUE

2. WALL PLATE FEATURES 3. INSTALL JUNCTION BOX

DMC-10AWP Audio Input Wall Plate Installation Instructions (760) 438-7000 USA & Canada (800) 421-1587 & (800) 392-0123 Toll Free FAX (800) 468-1340 www.linearcorp.com www.mssystems.com 4. ROUTE CAT-5 CABLE FOR WALL PLATE1. PRODUCT DESCRIPTION2. WALL PLATE FEATURES3. INSTALL JUNCTION BOX Linear’s M&S Systems brand Model DMC-10 Structured Wiring Intercom System is a distributed hub design that provides easy installation and structured wiring mounting compatibility. The Model DMC-10AWP Audio Input Wall Plate provides a method for playing an audio source through the DMC-10 intercom system’s room and patio stations. The wall plate mounts in a single-gang J-box and features two Type RCA audio input jacks, a mute output, a signal overload indicator, and a removable signal level adjustment control. The two audio inputs connect to the left and right channel line level outputs on the audio source component. The wall plate will convert the stereo inputs to a monaural output for the DMC-10 system. The signal overload indicator and signal level adjustment allows setting the wall plate for various input signal levels without distortion. The 3.5mm mute output jack provides a contact closure to interrupt an independent audio system whenever the DMC-10 intercom system is being used for communications. 5. PUNCH DOWN CABLE AT WALL PLATESIGNAL OVERLOAD INDICATOR LIGHTS WHEN INPUT SIGNAL LEVEL IS TOO HIGH SIGNAL LEVEL ADJUSTMENT TURN TO ADJUST AUDIO INPUT SIGNAL LEVEL MUTE OUTPUT DRY CONTACT CLOSURE FOR MUTING ANOTHER SYSTEM AUDIO INPUT JACKS LEFT AND RIGHT RCA JACKS FOR CONNECTING TO THE AUDIO SOURCE'S OUTPUT TYPE 110 PUNCH-DOWN FOR CONNECTING CAT-5 CABLE FROM INTERCOM HUB 6. INSTALL WALL PLATEINSTALL A SINGLE-GANG JUNCTION BOX AT A GOOD LOCATION FOR THE AUDIO INPUT BE SURE THE LOCATION IS EASILY ACCESSIBLE FOR THE TYPE OF AUDIO SOURCE BEING USED IN THE INSTALLATION AND THAT WIRING ACCESS IS POSSIBLE 7. PUNCH DOWN CABLE AT HUB MAXIMUM WIRE RUN: 500 FEET OF CAT-5 CABLE WALL PLATE FROM INTERCOM HIB J-BOX TO THE AUDIO INPUT WALL PLATE CAT-5 CABLE CAT-5 CABLES TO ENCLOSURE FROM STATIONS AND WALL PLATE NOTE: ONLY ONE AUDIO INPUT WALL PLATE IS RECOMMENDED STRUCTURED PER SYSTEM WIRING ENCLOSURE LABEL STATION AND WALL PLATE LOCATIONS ON CABLES 8. CONNECT INPUTPUNCH-DOWN CAT-5 CABLE WITH TYPE 110 TOOL BLUE STRIPE BLUE ORANGE STRIPE ORANGE GREEN STRIPE GREEN BROWN STRIPE BROWN DMC-10AWP WALL PLATE IMPORTANT: SET PUNCH-DOWN TOOL TO THE "LOW" FORCE SETTING AND SUPPORT THE AUDIO PLATE'S CIRCUIT BOARD DURING PUNCH-DOWN 9. OPTIONAL MUTE OUTPUTATTACH INPUT PLATE TO J-BOX WITH TWO SCREWS ATTACH WALL PLATE WITH TWO SCREWS 10. POWER UP AND TESTUSE A TYPE 110 PUNCH-DOWN TOOL TO TERMINATE CAT-5 CABLES FROM WALL PLATE AND STATIONS BLUE STRIPE BLUE ORANGE STRIPE ORANGE CONNECT GREEN STRIPE CAT-5 CABLE GREEN WIRES IN BROWN STRIPE THIS ORDER BROWN LIMITED WARRANTY

SIGNAL OVERLOAD INDICATOR

LIGHTS WHEN INPUT SIGNAL

1. PRODUCT DESCRIPTION Linear’s M&S Systems brand Model DMC-10 Structured Wiring

Intercom System is a distributed hub design that provides easy

WITH TYPE 110 TOOL

PUNCH-DOWN

BLUE STRIPE

BLUE

ORANGE STRIPE

ORANGE

GREEN STRIPE

GREEN

BROWN STRIPE

BROWN

CAT-5 CABLE

FROM STATIONS

AND WALL PLATE

INTO THE AUDIO INPUT

500 FEET OF CAT-5 CABLE FROM INTERCOM HIB

CAT-5 CABLES

AUDIO CABLE FROM

THE AUDIO SOURCE

PLUG A LINE-LEVEL

MAXIMUM WIRE RUN:

TO THE AUDIO INPUT

CONNECTORS

WALL PLATE

USA & Canada (800) 421-1587 & (800) 392-0123

DMC-10AWP

Toll Free FAX (800) 468-1340

www.linearcorp.com

www.mssystems.com

TO ENCLOSURE

STRUCTURED

WIRING

ENCLOSURE

WALL PLATE

CAT-5 CABLE

LABEL STATION

AND WALL PLATE

LOCATIONS

ON CABLES

Audio Input

J-BOX

Wall Plate

Installation

Instructions

NOTE: ONLY ONE AUDIO

INPUT WALL PLATE

IS RECOMMENDED

PER SYSTEM

(760) 438-7000

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Linear Intercom Wall Plate (DMC-10AWP)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Linear Intercom Wall Plate (DMC-10AWP)

Be the first to ask — other owners or our team will answer.

Original document

Linear Intercom Wall Plate (DMC-10AWP) manual PDF

1 pages·436 KB·Intercom System·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…