Page 1 of the Linear D-24A(/K) user manual — DESCRIPTION
Page 1 · click to enlarge
Page 1

Use a pointed object (other than a pencil or pen)

to set the keys. The ON position is when the top

of the switch is down, facing the numbers. The

OFF position is when the top of the switch is up

and the bottom is down, away from the numbers.

In the example shown in Figure 3, keys 1,4,6

Linear D-24A(/K) — INSTALLATION diagram (page 1)
Fig. 1
1. Select a location for the transmitter and

drive screws through the two countersunk holes of

the back cover to mount the cover (see Figure 4).

mounted above ground level (minimum of 3

2. For recessed switches with hidden

wiring, fish the sensor wires through the wire

access hole on the back cover. With surface

wiring, route the wire leads through the wire slot

Figure 4. Transmitter

To mount the transmitter, proceed as follows:

feet) the better the radio range should be.

and 8 are ON; keys 2,3,5 and 7 are OFF.

on the back cover (see Figure 4).

Figure 3. Example

INSTALLATION

The digital coding switch is attached to the circuit

board inside the case. To access the switch,

unsnap and slide off the back cover as shown in

Figure 1, exposing the battery, lead wire screw

terminals, and digital coding switch (see Figure 2).

Linear D-24A(/K) — INSTALLATION diagram (page 1)
Fig. 2

re-coded by installer prior to operation. DO NOT

Among the 256 possible codes, four codes are

considered invalid, and should not be used. They

areall keys ON, all keys OFF, and keys set

To set a code, select any valid combination of

ON and OFF positions for the switch keys

alternating ON/OFF or OFF/ON combinations.

USE THE FACTORY SET CODE!

CODE SWITCH LOCATION

numbered 1 through 8.

time delay of 1 to 3 seconds, ensuring that the

sensor circuit must be continuously open for at

least 1 second before the D-24A will transmit.

This feature helps prevent activation from

short-term, spurious signals, and from signals

made from outside electromagnetic sources.

The transmitter may be re-triggered after a

30-second reset time. The transmitter has a pushbutton for battery/transmission test.

must be closed for a minimum of 45 seconds

before the pushbutton will activate the

The D-26A is used with various types of security

sensors that are normally open. The

special-purpose D-26A transmitter has a built-in

exit/entry time delay. The timer starts when the

sensor circuit closes. It begins a 5 to 10 second

countdown. If no action is taken before the time

delay is completed, the transmitter will send an

alarm signal to its companion receiver. Pressing

the pushbutton before the time delay period

has elapsed will prevent signal transmission.

In addition to canceling time-delayed signal

transmission, the pushbutton is used to test the

battery. Pressing the button turns on the red

LED if the battery is in good condition. The LED

circuit that allows a single transmission of a

2-second duration to occur, followed by a 30-second reset time. This means that regardless of the number of times the transmitter is triggered,

it will not send a signal more often than once every

D-26A N/O TIME-DELAY TRANSMITTER

does not light upon transmission.

transmitter.

30 seconds.

The D-21A(/K), D-24A(/K), and D-26A(/K) are

digitally coded stationary radio transmitters

triggered by normally open (N/O) or normally

closed (N/C) sensors. These transmitters can

be programmed to activate any of Linear’s

standard digital receivers that are tuned to the

same frequency. Each transmitter can perform

many remote switching tasks and are typically

used in wireless/hardwire security systems.

Each unit is powered by a self-contained 9-volt

battery and can be connected to various

suffix are Linear’s Canadian models tuned to 318

MHz. These instructions pertain to both the /K

The D-21A is used with various types of security

sensors that are normally open (magnetic

contacts, security floor mats, etc.). The D-21A

transmits a signal when the sensor circuit

closes. The transmitter triggers instantly, and

may be re-triggered after a 30-second reset time.

A pushbutton is provided for battery/transmission

test. Pressing the pushbutton with the sensor

circuit open (after the 30-second reset) triggers

the transmitter and turns on the red LED if the

The D-24A is used with various types of security

sensors that are normally closed (magnetic

contacts, security window screens, etc.). The

D-24A transmits a signal when the sensor

circuit opens. The transmitter incorporates a

sensors with the built-in screw terminals.

and standard 303.875 MHz U.S. models.

D-21A N/O TRANSMITTER

D-24A N/C TRANSMITTER

battery is above 7.5 volts.

DESCRIPTION

Back Cover Mounting · Coding Switch

Page 2 of the Linear D-24A(/K) user manual — CHECKOUT AND TEST
Page 2 · click to enlarge
Page 2

Code Setting and

Installation Instructions

A NORTEK COMPANY

D-21A, D-21A/K,

D-24A, D-24A/K,

D-26A, D-26A/K

Digital Security

Transmitters

This Linear product is warranted against defects in material and

workmanship for twelve (12) months. The Warranty Expiration Date is

labeled on the product. This warranty extends only to wholesale

customers who buy direct from Linear or through Linear’s normal

distribution channels. Linear does not warrant this product to

consumers. Consumers should inquire from their selling dealer as to the

nature of the dealer’s warranty, if any. There are no obligations or

liabilities on the part of Linear corporation for consequential damages

arising out of or in connection with use or performance of this product

or other indirect damages with respect to loss of property, revenue,

or profit, or cost of removal, installation, or reinstallation. All implied

warranties, including implied warranties for merchantability and implied

warranties for fitness, are valid only until Warranty Expiration Date as

labeled on the product. This Linear Corporation Warranty is in lieu of

For warranty service on Linear equipment return product, at sender’s

Linear radio controls provide a reliable communications link and fill an

For U.S. installations onlyThe radios are required to comply with

FCC Rules and Regulations as Part 15 devices. As such, they have

Receivers may be blocked by radio signals that occur on or near

A receiver cannot respond to more than one transmitted signal at a time.

Infrequently used radio links should be tested regularly to protect

A general knowledge of radio and its vagaries should be gained

prior to acting as a wholesale distributor or dealer, and these facts

Copyright © 1992 Linear Corporation 200105 C

2350 Camino Vida Roble, Suite A 673 Consortium Court Carlsbad, CA 92009 London, Ontario, Canada N6E 2S8

their operating frequencies, regardless of code settings.

AttnRepairs Department Attn: Repairs Department

limited transmitter power and therefore limited range.

should be communicated to the ultimate users.

Linear Corporation Linear Canada Inc.

LINEAR LIMITED WARRANTY

against undetected interference or fault.

all other warranties express or implied.

U.S.A. Canada

limitations which must be observed.

IMPORTANT !!!

expense to:

operating properly, and that the transmitter’s

digital code is correctly matched to the code set

If the transmitter fails to activate the receiver,

first check the coding switches to see that the

switch keys in the transmitter and the receiver

are correctly matched. Next, check the battery

If the code is set correctly, the battery is good,

and the LED lights but the receiver dosen’t

activate, check for hidden metal obstacles or

large metal appliances between the transmitter

and receiver that may be blocking the radio

signal. Re-location of the transmitter or receiver

recommends that you test security equipment

frequently. From the time of installation, it is

absolutely necessary to test the system at

least once a week. Although the 9-volt battery

should last about a year, it is good practice to

Figure 7.

change the battery every six months.

CAUSES FOR NON-OPERATION

and replace it if it’s weak.

in the receiver.

3. Attach wires from the sensor switch to

the transmitter screw terminals. Wire normally

closed switches in series, and normally open

a total of four switches may be used with one

4. Slide the transmitter onto the back

cover until locked into place to complete

After installation, the transmitter and receiver

Activate the transmitter by triggering the sensor.

Verify that the LED lights when the sensor is

triggered (except for D-26A). Receiver

activation indicates that the transmitter is

Figure 5.

Figure 6.

switches in parallel (see Figures 5 & 6).

should be checked out as a system.

installation (see Figure 7).

CHECKOUT AND TEST

transmitter.

Show 13 more labels / short text on this page
Installation · (Door and · Typical · Window) · may be necessary · Normally · Normally · Open · Switch · Wiring · Closed · Switch · Wiring

Ask about the Linear D-24A(/K)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Linear D-24A(/K)

Be the first to ask — other owners or our team will answer.

Original document

Linear D-24A(/K) manual PDF

2 pages·121 KB·Chipper·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…