Instruction/ maintenance manual of the product EFO40 Hobart
Go to page of 12
701 S. RIDGE AVENUE TROY, OHIO 45374-0001 FORM 16903, Rev. E (3-98) MODEL EFO40 GAS FR YER ML-52051 ML-52074.
– 2 – © HOBART CORPORATION, 1994 IMPORT ANT FOR YOUR SAFETY THIS MANUAL HAS BEEN PREPARED FOR PERSONNEL QUALIFIED TO INSTALL GAS EQUIPMENT, WHO SHOULD PERFORM THE INITIAL FIELD START-UP AND ADJUSTMENTS OF THE EQUIPMENT COVERED BY THIS MANUAL.
– 3 – T ABLE OF CONTENTS GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
– 4 – Installation, Operation and Care of MODEL EFO40 GAS FR YER SA VE THESE INSTRUCTIONS FOR FUTURE USE GENERAL The Model EFO40 Gas Fryer features an accurate thermostat for frying consistency and enhanced oil life. The efficient gas burner provides prompt quiet ignition.
– 5 – INSTALLATION CODES AND STANDARDS Hobart fryers should be installed in accordance with: In the United States 1. State and local codes. 2. National Fuel Gas Code, ANSI-Z223.1 (latest edition), available from American Gas Association, Inc. 1515 Wilson Blvd.
– 6 – STRAIN RELIEF FITTING FOR GAS LINE THIS SIDE ONLY. (To be supplied by others.) PL-51194 Provide a restraining device for the gas line to limit movement of the fryer without depending on the connector and/or any quick-disconnect device or its associated piping to limit movement of the fryer.
– 7 – LEVELING After gas connections have been made, place a spirit level on top of the fryer and adjust the legs to level the fryer front-to-back and side-to-side in the final installed position.
– 8 – OPERA TION WARNING: HOT OIL AND PARTS CAN CAUSE BURNS. USE CARE WHEN OPERATING, CLEANING AND SERVICING THE FRYER. WARNING: SPILLING HOT OIL CAN CAUSE SEVERE BURNS.
– 9 – LIGHTING INSTRUCTIONS (Fig. 3) 1. Turn thermostat knob OFF. 2. Depress gas valve extension arm and turn to OFF. Wait 5 minutes for unburned gas to vent. 3. Depress gas valve extension arm and turn to PILOT. 4. While still depressing arm, light pilot with a lit taper.
– 10 – TURNING THE FRYER OFF 1. Turn thermostat OFF. 2. Turn gas valve extension arm to PILOT. In this position, the pilot continues to burn. 3. To shut off all gas to the system, including the pilot, turn gas valve extension arm to OFF. Extended Shutdown 1.
– 11 – • Add shortening as necessary for proper level. • Revitalize with approximately 15% new oil daily. CAUTION: Keep level of shortening at line above oil level line in fry tank. SHORTENING HINTS • Use good quality liquid shortening. • Maintain a good turnover ratio.
– 12 – CLEANING Weekly or as Needed After shortening has been drained, flush out scraps and sediment with a small quantity of warm shortening and allow tank to drain thoroughly. Close drain valve and fill tank with a non-corrosive, grease-dissolving commercial cleaner, following the manufacturer's instructions.
An important point after buying a device Hobart EFO40 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Hobart EFO40 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Hobart EFO40 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Hobart EFO40 you will learn all the available features of the product, as well as information on its operation. The information that you get Hobart EFO40 will certainly help you make a decision on the purchase.
If you already are a holder of Hobart EFO40, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Hobart EFO40.
However, one of the most important roles played by the user manual is to help in solving problems with Hobart EFO40. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Hobart EFO40 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center