2-1 Henny Penny Model OE-100 SECTION 2. MAINTENANCE 2-1. INTRODUCTION This section provides procedures for checking and replacement of the various parts used within the unit. Before replacing any parts, refer to Section 1, T roubleshooting. It will aid you in determining the cause of a particular malfunction.
Henny Penny Model OE-100 2-2 2-4. THERMAL SENSOR The thermal sensor determines the shortening temperature. If a mal- function does occur , an E6 will be displayed on the digital readout. T urn unit to OFF position, then back to COOK position. If E6 is still displayed, the thermal sensor must be replaced by following these steps: 1.
2-3 Henny Penny Model OE-100 2-5. HIGH TEMPERA TURE LIMIT CONTROL The high temperature limit control is a manual reset control which senses the temperature of the shortening. If the shortening temperature exceeds the safe operating limit, this control will open and shut off the heat to the frypot.
2-4 Model OE-100 409 2-5. HIGH TEMPERA TURE LIMIT CONTROL (Continued) Before following these steps, place POWER switch in the OFF position and unplug the power cord or open the wall circuit breaker . 1. If the tube is broken or cracked, the control will open, shutting off electrical power .
2-5 Henny Penny Model OE-100 2-6. HEA TING ELEMENTS NOTE Heating elements are available for 208 and 480 voltage. Check the data plate to determine the corr ect voltage. If the shortening's temperature recovery is very slow or at a slower rate than required, this may indicate defective heating element(s).
Henny Penny Model OE-100 2-6 2-6. HEA TING ELEMENTS (Continued) 1091 Replacement 1. Drain the shortening from the frypot. 2. Remove the heating element wire from the terminals by removing the nuts and washer . Label each so it can be replaced in the same position on the new element.
2-7 Henny Penny Model OE-100 2-7. CONT ACTORS The following checks are performed with the wall circuit breaker closed and the Power switch in the ON position. Extreme caution should be taken. Make connections before applying power , take reading, and Remove power before removing meter leads.
Henny Penny Model OE-100 2-8 2-8. F AN The Henny Penny OE-100 has a fan in the circuit which operates only when the power switch is in the COOK position. The fan helps keep the control panel cool by pulling out heat from between the control panel and frypot.
2-9 Henny Penny Model OE-100 2-8. F AN (Continued) 2 . Label and disconnect fan motor wires. 3. Remove the four screws, washers, and nuts securing the fan to the heat shield. 4. Remove the fan from the heat shield. 5. Install the new fan on the heat shield and secure with the four screws, washers, and nuts.
Henny Penny Model OE-100 2-10 2-10. FUSES T o avoid electrical shock or other injury , before starting this procedure, move power switch to the OFF position. Disconnect main circuit breaker at the circuit breaker box or unplug cord from wall receptacle.
2-11 Henny Penny Model OE-100 2-12. FIL TER HEA TER SWITCH Checkout The Filter Heater Switch is a rocker type switch. W ith the switch in the "ON" position, the filter heater will operate, melting any solidified shortening in the filter lines.
Henny Penny Model OE-100 2-12 2-13. FI L TER HEA TER 593 This unit is equipped with a strip heater in the event solidified shorten- ing accumulates in the filter pump lines. If this heater becomes defec- tive, replace by following these steps. Remove all power from unit.
2-13 Henny Penny Model OE-100 2-14. FIL TERING SYSTEM The filtering system consists of the filter valve, motor and filter pump assembly , filter screen assembly , and tubing. Shortening with temperature in excess of 200 OF flows through this filter rinse hose.
Henny Penny Model OE-100 2-14 2-15. FI L TER V AL V E The filter valve is a 3/8 inch two-way stainless steel ball valve. If this valve should develop leaks the entire valve must be replaced. T o avoid electrical shock or other injury before starting this procedure move COOK/PUMP SWITCH to OFF position.
2-15 Henny Penny Model OE-100 2-16. FIL TER PU MP REP AIR (Continued) 3. T o reassemble, place rotor on drive shaft, and place rollers into rotor . NOTE A small amount of shortening might be needed to hold the bottom roller into place until cover plate is put on.
Henny Penny Model OE-100 2-16 2-18. PUMP AND MOTOR REPLACEMENT 1. T o replace the pump and motor assembly , insure the main power has been removed from the fryer . T o avoid electrical shock, injury or burns before starting this procedure move COOK/PUMP SWITCH to OFF position.
2-17 Henny Penny Model OE-100 2-19. COOLING F AN MAINTENANCE (Continued) 5. Close door and turn power switch on. Unit is now ready for operation. If the fan needs a more thorough cleaning, or E-4 persists after cleaning the fan guard, follow the following steps.
Henny Penny Model OE-100 2-18 994.
2-19 Henny Penny Model OE-100 1 197.
Henny Penny Model OE-100 2-20 1 197.
2-21 Henny Penny Model OE-100 694.
Henny Penny Model OE-100 2-22 1294.
An important point after buying a device Henny Penny OE-100 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Henny Penny OE-100 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Henny Penny OE-100 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Henny Penny OE-100 you will learn all the available features of the product, as well as information on its operation. The information that you get Henny Penny OE-100 will certainly help you make a decision on the purchase.
If you already are a holder of Henny Penny OE-100, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Henny Penny OE-100.
However, one of the most important roles played by the user manual is to help in solving problems with Henny Penny OE-100. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Henny Penny OE-100 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center