enny This section provides the installation instructions for the Henny Penny Fry Station. Installation of the unit should be performed only by a qualified service technician. Do not puncture the unit with any objects such as drills or screws as component damage or electrical shock could result.
The proper location of the Fry Station is very important for operation, speed, and convenience. The location of the fiy station should allow clearances for servicing and proper operation. Choose a location which will provide easy loading and unloading without interfering with the final assembly of food orders.
When installing the gas fry station do not attach an exten- sion to the gas flue exhaust stack. This may impair proper operation of the burner, causing malfunctions and possible negative back draft. The gas fry station is factory available for either natural or propane gas.
T INIMU~I PULL of equip- ment away from wall permissible for accessi- bility to Quick Disconnect Device. AVOID SHARP BENDS AND KINKS when pulling equipment away from wall. (Max- imum pull will kink ends, even if installed properly, and reduce Connector life.
A standard one inch, black steel pipe and malleable fittings should be used for gas service connections. Do not use cast iron fittings. Although one inch size pipe is‘reconunended, piping should be .
The following steps provide the pilot PROCEDURE lighting procedure: 1. Open doors and open gas shut-off valve. (see illustrations) 2. The gas cock dial has a dual function: a. Complete control of gas to the pilot and main burner. b. When in the pilot position, it is the reset mechanism for the automatic pilot.
Depress lightly and turn manual lever on gas valve to the OFF position. The gas pressure regulator on the automatic gas valve is factory set as follows: @ Natural: 3.5 inches water column. * Propane 10 0 inches water column. e 120 V, 50/60 Hz., 12 A, 1 PH 0 230 V, 50/60 HZ.
I The OE-301/302/303 is available from the factory wired 208, or 220/240 volts, 50 or 60 hertz source. Refer to the table below for supply wiring and fusing. Volts Phase KW Amps 208 3 11.25 31 208 3 13.50 38 220/240 3 11.25 30132 2201240 3 13.50 33135 400 3 11.
An important point after buying a device Henny Penny OE 301 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Henny Penny OE 301 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Henny Penny OE 301 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Henny Penny OE 301 you will learn all the available features of the product, as well as information on its operation. The information that you get Henny Penny OE 301 will certainly help you make a decision on the purchase.
If you already are a holder of Henny Penny OE 301, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Henny Penny OE 301.
However, one of the most important roles played by the user manual is to help in solving problems with Henny Penny OE 301. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Henny Penny OE 301 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center