Frymaster UHC-HD
Table of Contents 17 sections UHC-HD Service, Parts Manual for 6, 3-Row Models · 819-6606 OCT 10 · DO NOT OPERATE THE CABINET UNLESS IT HAS BEEN PROPERLY INSTALLED AND · USE CAUTION WHEN SETTING UP, OPERATING, OR CLEANING THE CABINET TO AVOID · … ShowHide
Page 1 of the Frymaster UHC-HD user manual — 819-6606 OCT 10
Page 1 · click to enlarge
Page 1

UHC-HD Service, Parts Manual for 6, 3-Row Models

Frymaster UHC-HD — UHC-HD Service, Parts Manual for 6, 3-Row Models diagram (page 1)
Fig. 1 · UHC-HD Service, Parts Manual for 6, 3-Row Models
Frymaster UHC-HD — UHC-HD Service, Parts Manual for 6, 3-Row Models diagram (page 1)
Fig. 2 · UHC-HD Service, Parts Manual for 6, 3-Row Models
Frymaster UHC-HD — UHC-HD Service, Parts Manual for 6, 3-Row Models diagram (page 1)
Fig. 3 · UHC-HD Service, Parts Manual for 6, 3-Row Models
Frymaster UHC-HD — UHC-HD Service, Parts Manual for 6, 3-Row Models diagram (page 1)
Fig. 4 · UHC-HD Service, Parts Manual for 6, 3-Row Models
Frymaster UHC-HD — UHC-HD Service, Parts Manual for 6, 3-Row Models diagram (page 1)
Fig. 5 · UHC-HD Service, Parts Manual for 6, 3-Row Models

Frymaster, a member of the Commercial Food Equipment Service Association, recommends using CFESA Certified Technicians. *8196606* 24-Hour Service Hotline 1-800-551-8633

Price$6.00

819-6606 OCT 10

Page 2 of the Frymaster UHC-HD user manual — USE CAUTION WHEN SETTING UP, OPERATING, OR CLEANING THE CABINET TO AVOID
Page 2 · click to enlarge
Page 2

NOTICE IF, DURING THE WARRANTY PERIOD, THE CUSTOMER USES A PART FOR THIS ENODIS EQUIPMENT OTHER THAN AN UNMODIFIED NEW OR RECYCLED PART PURCHASED DIRECTLY FROM FRYMASTER DEAN, OR ANY OF ITS AUTHORIZED SERVICE CENTERS, AND/OR THE PART BEING USED IS MODIFIED FROM ITS ORIGINAL CONFIGURATION, THIS WARRANTY WILL BE VOID. FURTHER, FRYMASTER DEAN AND ITS AFFILIATES WILL NOT BE LIABLE FOR ANY CLAIMS, DAMAGES OR EXPENSES INCURRED BY THE CUSTOMER WHICH ARISE DIRECTLY OR INDIRECTLY, IN WHOLE OR IN PART, DUE TO THE INSTALLATION OF ANY MODIFIED PART AND/OR PART RECEIVED FROM AN UNAUTHORIZED SERVICE CENTER.

THE CABINET IS NOT SUITABLE FOR OUTDOOR USE. WHEN OPERATING THIS UNIT, IT

MUST BE PLACED ON A HORIZONTAL SURFACE.

THE CABINET IS NOT SUITABLE FOR INSTALLATION IN AN AREA WHERE A WATER JET

CAN BE USED. THIS APPLIANCE MUST NOT BE CLEANED WITH A WATER JET.

FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN

THE VICINITY OF THIS OR ANY OTHER APPLIANCE.

DO NOT OPERATE OR SERVICE THE CABINET WITHOUT FIRST READING THIS MANUAL.

DO NOT OPERATE THE CABINET UNLESS IT HAS BEEN PROPERLY INSTALLED AND

CHECKED.

DO NOT OPERATE THE CABINET UNLESS ALL SERVICE AND ACCESS PANELS ARE IN

PLACE AND PROPERLY SECURED.

DO NOT ATTEMPT TO REPAIR OR REPLACE ANY COMPONENT OF THE CABINET UNLESS

ALL POWER TO THE UNIT HAS BEEN DISCONNECTED.

USE CAUTION WHEN SETTING UP, OPERATING, OR CLEANING THE CABINET TO AVOID

CONTACT WITH HEATED SURFACES.

USE CAUTION WHEN LIFTING THE UHC-D. THE UNIT WEIGHS 200 POUNDS. THREE TO FOUR PEOPLE, USING STANDARD SAFE LIFTING PRACTICES, WILL BE NECESSARY TO

HANDLE THE CABINET.

Page 5 of the Frymaster UHC-HD user manual — 1.3 Start Up Indicators and Test Points
Page 5 · click to enlarge
Page 5

1.3 Start Up Indicators and Test Points

Frymaster UHC-HD — 1.3 Start Up Indicators and Test Points diagram (page 5)
Fig. 6 · 1.3 Start Up Indicators and Test Points
Frymaster UHC-HD — 1.3 Start Up Indicators and Test Points diagram (page 5)
Fig. 7 · 1.3 Start Up Indicators and Test Points

Distribution boards shown with ribbon cables removed.

Frymaster UHC-HD — 1.3 Start Up Indicators and Test Points diagram (page 5)
Fig. 8 · 1.3 Start Up Indicators and Test Points
Frymaster UHC-HD — 1.3 Start Up Indicators and Test Points diagram (page 5)
Fig. 9 · 1.3 Start Up Indicators and Test Points
Frymaster UHC-HD — 1.3 Start Up Indicators and Test Points diagram (page 5)
Fig. 10 · 1.3 Start Up Indicators and Test Points

Upon startup, the cabinet beeps. LED’s on the distribution boards flash. The displays show the version number of the cabinet’s firmware and then the row’s status.

Page 6 of the Frymaster UHC-HD user manual — 1.3 Start Up Indicators and Test Points
Page 6 · click to enlarge
Page 6

2 Service Procedures DANGER: Failure to disconnect power from the unit before servicing could result in serious injury or death. The cabinet power switch DOES NOT disconnect all incoming power to the cabinet. 2.1 Updating Software/Capturing Configurations The five sections of software on the cabinet can be updated individually. To ensure compatibility between cabinet software and replacement boards, the software should be updated to the latest version at any board replacement. Follow the directions below. Software updates use the master control display to enter programming codes, scroll to areas to be revised, respond to questions and exit. The control is annotated above. The arrow and OK buttons are illuminated when active. Check Existing Versions

Frymaster UHC-HD — 1.3 Start Up Indicators and Test Points diagram (page 6)
Fig. 11 · 1.3 Start Up Indicators and Test Points
Frymaster UHC-HD — 1.3 Start Up Indicators and Test Points diagram (page 6)
Fig. 12 · 1.3 Start Up Indicators and Test Points
Frymaster UHC-HD — 1.3 Start Up Indicators and Test Points diagram (page 6)
Fig. 13 · 1.3 Start Up Indicators and Test Points
Frymaster UHC-HD — 1.3 Start Up Indicators and Test Points diagram (page 6)
Fig. 14 · 1.3 Start Up Indicators and Test Points

Fig. 2: Tabs in the topcap extend to holes in the cabinet. The top is secured with at the tabs with screws.

Frymaster UHC-HD — 1.3 Start Up Indicators and Test Points diagram (page 6)
Fig. 15 · 1.3 Start Up Indicators and Test Points

Fig. 1: The sides are held in place by screws near the base of the unit on each side.

Frymaster UHC-HD — 1.3 Start Up Indicators and Test Points diagram (page 6)
Fig. 16 · 1.3 Start Up Indicators and Test Points
Frymaster UHC-HD — 1.3 Start Up Indicators and Test Points diagram (page 6)
Fig. 17 · 1.3 Start Up Indicators and Test Points
KeypadEnter programming

Power Switch: Cycle power between each revision update.

OK: Press to confirm choices.

Arrows: Scroll to choices.

Programming key: Press prior to entering programming code.

  • 1. With the unit powered up, press the programming key. 2. Screen scrolls Enter Access Sequence. 3. Enter 090809 on keypad. 4. Press OK. 5. Scroll with arrow keys to view all software revision numbers:
  • Main
  • Boot Loader
  • Master Display
  • Distribution Board
  • Row Display 6. Press OK.

d

Page 7 of the Frymaster UHC-HD user manual — 1.3 Start Up Indicators and Test Points
Page 7 · click to enlarge
Page 7
UpdateBoards

Loading Sequence Software should be loaded in this sequence:

1. Turn power off. 2. Insert flash drive in USB port located on cabinet bezel. 3. Turn power on. 4. Cabinet displays version numbers followed by current menu setting. 5. Press programming key. 6. Screen scrolls Enter Access Sequence. 7. Enter 98765 with keypad. 8. Press OK. 9. Scroll with arrow key until software section (see loading sequence box) to be updated is displayed on master control board. 10. Press OK. 11. Screen displays Copying Files, Please Wait. This takes several minutes. 12. Screen messages will vary, depending on software section being installed. Follow screen instructions. 13. Screen displays Complete. 14. Press OK. 15. Screen displays Main Boot Loading and a percentage of completion. 16. After 100% is displayed, screen goes blank and returns to menu display. 17. Turn cabinet off for 30 seconds and back on. Update: Language File

  • Main Board
  • Language
  • Row Display
  • Distribution Boards If the software update only involves a few of the components, following the loading sequence, skipping the unneeded component.

Incompatibility Message The cabinet can display an incompatibility message during software upgrades. The buttons will remain active. Follow the loading sequence and the incompatibility is corrected as the software components are loaded.

1. With the unit on, press program button. 2. Enter 090709 with the keypad. 3. Press OK. 4. Screen displays Reconfigure OK or Cancel. 5. Press OK. 6. Screen displays Please Wait Lang Bin. 7. Screen displays 9 files copied. 8. Press OK. 9. Screen returns to normal display. 10. Turn cabinet off for 30 seconds and back on. Capture Cabinet Menus/Configurations The menu items and cabinet configurations in a cabinet can be captured and used to configure cabinets with identical software setups. Follow the instructions below to capture the menus and configuration from a cabinet.

1. Insert an empty flash drive in the USB socket on the cabinet with menus and configurations to be copied. 2. Press the programming key. 3. Enter 759248 with the keypad. 4. Press OK. 5. The master control will display Copy from UHC to
Frymaster UHC-HD — 1.3 Start Up Indicators and Test Points diagram (page 7)
Fig. 18 · 1.3 Start Up Indicators and Test Points
Frymaster UHC-HD — 1.3 Start Up Indicators and Test Points diagram (page 7)
Fig. 19 · 1.3 Start Up Indicators and Test Points

The configuration of a cabinet can be captured on an empty flash drive for transfer to cabinets with the same software setup.

Page 8 of the Frymaster UHC-HD user manual — 1.3 Start Up Indicators and Test Points
Page 8 · click to enlarge
Page 8

USB. 6. Press OK. 7. The master control displays Please Wait… as files are transferred to the flash drive, changing to the number of files copied when the process is complete. 8. Press OK. 9. Remove flash drive. 10. Cabinet returns to normal display. Configure Cabinet with Menu/Configuration Captured on another Cabinet

Frymaster UHC-HD — 1.3 Start Up Indicators and Test Points diagram (page 8)
Fig. 20 · 1.3 Start Up Indicators and Test Points
Frymaster UHC-HD — 1.3 Start Up Indicators and Test Points diagram (page 8)
Fig. 21 · 1.3 Start Up Indicators and Test Points

A cabinet configuration can be transferred to multiple cabinets with a captured configuration held on a flash drive.

Cabinet Access Codes CodeFunction 759248Capture cabinet configuration to flash drive 98765Load software updates from USB drive 1955Enter manual programming mode (see operation manual). 4557LON Works service pin 090809View software versions 1111Service test mode 090709Update language file
Page 9 of the Frymaster UHC-HD user manual — 1.3 Start Up Indicators and Test Points
Page 9 · click to enlarge
Page 9

2.2 Placing the cabinet in Service Mode The cabinet can be put in service mode, a diagnostic settings which allows the heater plates to be controlled individually, brightness settings on the displays adjusted and re-addressing for unique arrangements of bezels. Follow the steps below : Switching Heater Plates Off Individually When troubleshooting, it may be useful to switch heater plates off individually. Follow the instructions below:

Frymaster UHC-HD — 1.3 Start Up Indicators and Test Points diagram (page 9)
Fig. 22 · 1.3 Start Up Indicators and Test Points

1. Press the programming key. 2. Enter 1111 at the Enter Access Sequence prompt. 3. The screen will scroll Row 1 Top Heater Off; pressing OK turns it back on. 4. Voltage can be measured between the plate-specific heater leads on the distribution board and the common block to the right of the distribution board as the heater plates are switched, individually, on and off. 5. Scroll to other plates with WX. 6. Ensure the plates are on before backing out of the Service Mode with the /. Adjusting Display Brightness When multiple row positions are timing the same item, the display with the least remaining time is the brightest. All others are dimmer as are positions not actively timing a product. The relative brightness of the bright display and the dim display can be adjusted. Follow the instructions below:

1. Press the programming key. 2. Enter 1111 at the Enter Access Sequence prompt. 3. Press OK. 4. The screen will scroll Row 1 Top Heater Off. 5. Scroll with X through all the Heater Plate prompts until the screen displays Press OK to Adjust Bright Row Display. 6. Press OK. 7. The cabinet’s row displays become Decrease Increase 88888 20 8. Press the timer button next to the Decrease display to lessen the brightness; the number displayed at the right will decrease. Press the timer button next to the Increase display to increase the brightness; 20 is the maximum. 9. Press OK. The display becomes Adjust Dim Intensity. The cabinet’s row displays become Decrease Increase 88888 03 10. Press the timer button next to the Decrease display to lessen the brightness; the number displayed at the right will decrease. Press the timer button next to the Increase display to increase the brightness; 1 is the minimum. 11. Press OK. 12. Cabinet returns to menu display.

Page 10 of the Frymaster UHC-HD user manual — 1.3 Start Up Indicators and Test Points
Page 10 · click to enlarge
Page 10

Readdressing the Cabinet Addressing, or assigning a position-specific component such as a display or distribution board, is done automatically by the cabinet on startup. Communication errors can occur on start-up after a board installation however. If so, follow the instructions below to readdress the cabinet. This process can also be used during troubleshooting when displays are connected out of synch with their associated bezel on the same row level.

1. Press the programming key. 2. Enter 1111 at the Enter Access Sequence prompt. 3. The screen will scroll Row 1 Top Heater Off. 4. Scroll with X through all the Heater Plate prompts until the screen displays Press OK to ReAddress. 5. Press OK. 6. Screen Displays Please Power Cycle Off. 7. Turn the cabinet off and back on. 8. The cabinet will start in the normal start-up sequence.
Page 11 of the Frymaster UHC-HD user manual — 2.4 Circuit Board LED Diagnostics Master Control Board:
Page 11 · click to enlarge
Page 11

2.3 Accessing the Electronic Components 1. The component shelf is accessed by removing two screws on each side of the unit (Fig. 1). 2. Lift and remove the sides, which exposes screws that hold the top in place (Fig. 2). 3. The components are annotated below (Fig. 3). All the components are readily removed. There are no replaceable components on the circuit boards.

Frymaster UHC-HD — 2.4 Circuit Board LED Diagnostics Master Control Board: diagram (page 11)
Fig. 23 · 2.4 Circuit Board LED Diagnostics Master Control Boa…

Fans: are specific to regions of the cabinet and ducted to direct the air flow.

Master Control Board LON board

Frymaster UHC-HD — 2.4 Circuit Board LED Diagnostics Master Control Board: diagram (page 11)
Fig. 24 · 2.4 Circuit Board LED Diagnostics Master Control Boa…
Frymaster UHC-HD — 2.4 Circuit Board LED Diagnostics Master Control Board: diagram (page 11)
Fig. 25 · 2.4 Circuit Board LED Diagnostics Master Control Boa…
Frymaster UHC-HD — 2.4 Circuit Board LED Diagnostics Master Control Board: diagram (page 11)
Fig. 26 · 2.4 Circuit Board LED Diagnostics Master Control Boa…
Frymaster UHC-HD — 2.4 Circuit Board LED Diagnostics Master Control Board: diagram (page 11)
Fig. 27 · 2.4 Circuit Board LED Diagnostics Master Control Boa…

2.4 Circuit Board LED Diagnostics Master Control Board:

Frymaster UHC-HD — 2.4 Circuit Board LED Diagnostics Master Control Board: diagram (page 11)
Fig. 28 · 2.4 Circuit Board LED Diagnostics Master Control Boa…
  • HB LED is a heartbeat; should be flashing when in the normal inuse mode. Flash rate is not critical.
  • ACT LED similar to HB but flashes at a faster rate.
  • OK LED toggles each time a valid communication packet is sent and received. Normally a very fast flicker.
Frymaster UHC-HD — 2.4 Circuit Board LED Diagnostics Master Control Board: diagram (page 11)
Fig. 29 · 2.4 Circuit Board LED Diagnostics Master Control Boa…
Fig. 4Master Control Board LED's
Show 6 more labels / short text on this page
Master Display Board · LON filter · Cooling fans · LON filter · Power supply · Relay
Page 12 of the Frymaster UHC-HD user manual — 2.4 Circuit Board LED Diagnostics Master Control Board:
Page 12 · click to enlarge
Page 12
  • ERR LED toggles when a communication error is detected; it’s not unusual to see a flash, but regular flashing means communications problems.
  • LED5 and LED6 used for programming/debugging; have no diagnostic function.
  • LED7 When lit, the master control is executing a time or temp query operation on the front side.
  • LED8 When lit, the master control is executing a time or temp query operation on the back side. Distribution Board
Frymaster UHC-HD — 2.4 Circuit Board LED Diagnostics Master Control Board: diagram (page 12)
Fig. 30 · 2.4 Circuit Board LED Diagnostics Master Control Boa…
Frymaster UHC-HD — 2.4 Circuit Board LED Diagnostics Master Control Board: diagram (page 12)
Fig. 31 · 2.4 Circuit Board LED Diagnostics Master Control Boa…
Fig. 5Distribution Board LED's
Sensor (°F)ResistanceSensor (°C) 60106.06515.55 70108.22421.11 80110.38026.66 90112.53232.22 100114.68037.77 110116.82543.33 120118.96648.88 130121.10454.44 140123.23960.00 150125.36965.55 160127.49671.11 170129.62076.66 180131.74082.22 190133.85687.77 200135.96993.33 210138.07898.88 220140.184104.44 230142.286110.00 240144.385115.55 250146.480121.11 260148.570126.66
Page 13 of the Frymaster UHC-HD user manual — 2.4 Circuit Board LED Diagnostics Master Control Board:
Page 13 · click to enlarge
Page 13

suspect heater. Note: Line voltage is only seen when the row is calling for heat. 2. Check for line voltage between the power input terminal and the terminal block. 3. Check for +5VDC at the power-in terminal and the terminal block for the power supply. NOTE: After testing, reconnect all connections to their original positions. 2.5.4 Display 1. Remove power from unit. 2. Connect the ribbon cable from a suspect display to the connector of a properly working display to isolate the problem to the display or the distribution board. 3. Reapply power to cabinet. 2.5.5 Shorted Triac 1. Turn the suspect row off and measure voltage between the suspect heater lead on the distribution board and the terminal block. With the row off, there should be no line voltage. If the triac is shorted, you will measure AC line voltage. If the triac is half waving, you will get DC voltage of approximately one-half the line AC voltage.

Frymaster UHC-HD — 2.4 Circuit Board LED Diagnostics Master Control Board: diagram (page 13)
Fig. 32 · 2.4 Circuit Board LED Diagnostics Master Control Boa…
Frymaster UHC-HD — 2.4 Circuit Board LED Diagnostics Master Control Board: diagram (page 13)
Fig. 33 · 2.4 Circuit Board LED Diagnostics Master Control Boa…
Frymaster UHC-HD — 2.4 Circuit Board LED Diagnostics Master Control Board: diagram (page 13)
Fig. 34 · 2.4 Circuit Board LED Diagnostics Master Control Boa…
Frymaster UHC-HD — 2.4 Circuit Board LED Diagnostics Master Control Board: diagram (page 13)
Fig. 35 · 2.4 Circuit Board LED Diagnostics Master Control Boa…

Fig. 6: Distribution board shown with display cables removed.

2.5.6 Heater Plate 1. Disconnect power to the cabinet. Remove side and top panels. Disconnect the black heater lead and the RTD leads (brown and red) of the suspect plate from distribution board. Measure resistance of the heater from the black lead to any terminal on the white terminal block. Resistance should be 140-150 ohms.

2. Measure resistance across the brown and red RTD leads. Resistance must be within a range of 104-148 ohms. Resistance at room temperature is approximately 107 ohms. See chart on Page 2-4 for resistance at different temperatures. If either resistance is incorrect, replace the heater plate.

2.5.7 Display Meanings 1. ROW TEMP HIGH OR ROW TEMP LOW and no audible alarm. This is normal when the row is changing temperature in association with a menu change.

2. LLLL means the RTD indicates a temperature below 50°F (10°C). Unit will automatically heat at 20 percent until temperature is above 50°F (10°C), then operate normally.
Page 14 of the Frymaster UHC-HD user manual — 2.4 Circuit Board LED Diagnostics Master Control Board:
Page 14 · click to enlarge
Page 14
3. HHHH means RTD indicates the temperature is above 255°F (124°C), but below "Open" circuit resistance, which causes SENS ALARM .
Frymaster UHC-HD — 2.4 Circuit Board LED Diagnostics Master Control Board: diagram (page 14)
Fig. 36 · 2.4 Circuit Board LED Diagnostics Master Control Boa…
4. UHC VERSION _ _ _ (version number will vary) appears for five seconds when the unit is turned on. 5. The cabinet also displays a variety of error messages, which are shown on page 3-1. 2.6 Removing/Replacing Bezels
Frymaster UHC-HD — 2.4 Circuit Board LED Diagnostics Master Control Board: diagram (page 14)
Fig. 37 · 2.4 Circuit Board LED Diagnostics Master Control Boa…
Frymaster UHC-HD — 2.4 Circuit Board LED Diagnostics Master Control Board: diagram (page 14)
Fig. 38 · 2.4 Circuit Board LED Diagnostics Master Control Boa…

1. Remove power from unit. 2. Remove screws at the base of each side and remove side panels. (See figure 7.) 3. Unplug the bezel from the distribution board. 4. Plug the replacement bezel into the distribution board, return power to the unit and test the bezel/cabinet for accurate operation. 5. Remove replacement bezel and remove power from the unit. 6. Loosen the hex nut which secures the row and remove the allen screw, which holds the bezel. Also remove, if present, the small bezel-securing screw. (See photo below.) 7. Push, if necessary, on the mounted bezel through the access port in the inner panel to loosen the bezel. (See Figure 8 below.) 8. Remove bezel; clean and degrease the groove in the heater plate. 9. Route ribbon cable for the new bezel through the inner panel of the cabinet and press the new bezel into place. Ensure it is firmly seated and tighten hex nuts and replace allen screws. 10. Return sides and reposition cabinet for operation.

Frymaster UHC-HD — 2.4 Circuit Board LED Diagnostics Master Control Board: diagram (page 14)
Fig. 39 · 2.4 Circuit Board LED Diagnostics Master Control Boa…

Fig. 7: Two screws (see arrows) at the base of each side of the cabinet secure the sides.

Frymaster UHC-HD — 2.4 Circuit Board LED Diagnostics Master Control Board: diagram (page 14)
Fig. 40 · 2.4 Circuit Board LED Diagnostics Master Control Boa…
Frymaster UHC-HD — 2.4 Circuit Board LED Diagnostics Master Control Board: diagram (page 14)
Fig. 41 · 2.4 Circuit Board LED Diagnostics Master Control Boa…
Frymaster UHC-HD — 2.4 Circuit Board LED Diagnostics Master Control Board: diagram (page 14)
Fig. 42 · 2.4 Circuit Board LED Diagnostics Master Control Boa…
Frymaster UHC-HD — 2.4 Circuit Board LED Diagnostics Master Control Board: diagram (page 14)
Fig. 43 · 2.4 Circuit Board LED Diagnostics Master Control Boa…
Frymaster UHC-HD — 2.4 Circuit Board LED Diagnostics Master Control Board: diagram (page 14)
Fig. 44 · 2.4 Circuit Board LED Diagnostics Master Control Boa…
Frymaster UHC-HD — 2.4 Circuit Board LED Diagnostics Master Control Board: diagram (page 14)
Fig. 45 · 2.4 Circuit Board LED Diagnostics Master Control Boa…

Fig. 8: Loosen the hex bolt and remove the allen screw (arrows, upper photo). Some row positions may have an additional screw securing the bezel to the cabinet (lower photo). Push through the access port (arrow, upper photo), if necessary, to remove the bezel from the cabinet .

Page 15 of the Frymaster UHC-HD user manual — 2.6.3 Replace Heater Plate/RTD
Page 15 · click to enlarge
Page 15

2.6. 1 Removing/Replacing a Distribution Board or Communication Board

1. Remove power. 2. Remove and mark the wires on the faulty component. 3. Remove the board by lifting it from its standoffs. 4. Position the new board and attach wires. 5. Reapply power. 6. Run readdress steps on page 2-4. 2.6.2 Removing a Row
Frymaster UHC-HD — 2.6. 1 Removing/Replacing a Distribution Board or Communication Board diagram (page 15)
Fig. 46 · 2.6. 1 Removing/Replacing a Distribution Board or Co…
Frymaster UHC-HD — 2.6. 1 Removing/Replacing a Distribution Board or Communication Board diagram (page 15)
Fig. 47 · 2.6. 1 Removing/Replacing a Distribution Board or Co…
Frymaster UHC-HD — 2.6. 1 Removing/Replacing a Distribution Board or Communication Board diagram (page 15)
Fig. 48 · 2.6. 1 Removing/Replacing a Distribution Board or Co…
1. Remove the sides and top as shown in earlier steps. Disconnect the faulty row from the distribution board, and terminal block.
Frymaster UHC-HD — 2.6. 1 Removing/Replacing a Distribution Board or Communication Board diagram (page 15)
Fig. 49 · 2.6. 1 Removing/Replacing a Distribution Board or Co…
Frymaster UHC-HD — 2.6. 1 Removing/Replacing a Distribution Board or Communication Board diagram (page 15)
Fig. 50 · 2.6. 1 Removing/Replacing a Distribution Board or Co…
2. Remove the bezels on each end of the affected row, as shown in earlier steps, and the necessary adjacent bezels to remove the row.

Fig. 9: A row is shown partially removed from the cabinet.

3. Remove wire wraps from wiring harness holding heater and control wires for affected row.
4. Lifting slightly, carefully slide the malfunctioning row out of the cabinet. Do not allow the row to contact or damage the controls of the unit below ( Fig. 9 ).

2.6.3 Replace Heater Plate/RTD

1. Remove row as shown above.
2. Run your fingers around the outside surface of the row assembly. There are four raised areas. These are the setscrews, which hold the heater plate to the spacer. Punch holes in the insulation, directly above the location of the setscrews. ( Fig. 10, 11 ).
3. Use an allen wrench to loosen the four spacer-setscrews along the edges of the plate.
4. Slide the malfunctioning plate out of the spacer.
Frymaster UHC-HD — 2.6.3 Replace Heater Plate/RTD diagram (page 15)
Fig. 51 · 2.6.3 Replace Heater Plate/RTD
5. Slide the replacement plate into position. Make sure the plate is inserted squarely. Tighten set screws.
6. Route the wires to one end of the row and wire tie the power wires together. Also wire tie the RTD wires together. Stand the row on the opposite end adjacent to the cabinet and feed the wires into the cabinet.
7. Carefully slide the row far enough into the cabinet to be stable.
8. On the opposite side, reach into the cavity and direct the wires through the appropriate grommets to reach the power and RTD connections on the distribution board.

Fig. 10, 11: Find the set screws under the foil insulation and push through with an allen wrench.

Page 16 of the Frymaster UHC-HD user manual — 2.6. 1 Removing/Replacing a Distribution Board or Communication Board
Page 16 · click to enlarge
Page 16
9. Slide the row assembly completely into the cabinet and return the spacers between the heater plates. Ensure the row is evenly positioned in the cabinet. There must be sufficient space to allow the bezel tabs to fit between the outside row plate and the cabinet interior wall.
Frymaster UHC-HD — 2.6. 1 Removing/Replacing a Distribution Board or Communication Board diagram (page 16)
Fig. 52 · 2.6. 1 Removing/Replacing a Distribution Board or Co…
10. Replace the bezels.

Fig. 12: The heater plate slides from the insulation.

Tightening the setscrews will ensure the plate is properly grounded.

Page 17 of the Frymaster UHC-HD user manual — Cabinet Troubleshooting
Page 17 · click to enlarge
Page 17

Cabinet Troubleshooting

The master control display and the row displays show error messages when there is a problem. The messages are shown in the matrix below along with possible causes and diagnostic tests.

Error Message Cause Tests Call service row display error Row number also displayed *

  • Turn the cabinet off and back on.
  • Ensure there are no software incompatibilities.
  • Inspect ribbon cable connections. Call service distribution board 0 error*

The master control board has lost communication with the specified board.

The master control board has lost communication with the top distribution board.

  • A display connection can produce this display. Before replacing a distribution board, remove power from the unit and disconnect the displays from the affected distribution board. Return power to the unit and, one at a time, plug in the displays, cycling power each time. If the problem is display‐ related it will go away with the affected display disconnected.

The master control board has lost communication with the bottom distribution board.

Call service distribution board 1 error*

  • Turn the cabinet off and on, which can clear the problem if it is software related.
  • Check top plate RTD output against chart on page 2‐4.
  • Enter service code (see page 2‐1) and switch top plate on and off to ensure it is responding to cabinet circuits.

Row’s top plate failed to reach required temperature in prescribed time window after startup or when switching between menus.

Call service rate of rise top**

  • Turn the cabinet off and on, which can clear the problem if it is software related.
  • Check bottom plate RTD output against chart on page 2‐4.
  • Enter service code (see page 2‐1) and switch bottom plate on and off to ensure it is responding to cabinet circuits.

Row’s bottom plate failed to reach required temperature in prescribed time window after startup or when switching between menus.

Call service rate of rise bot **

  • Compare plate temperature to displayed temperature.
  • Compare plate RTD resistance to chart on page 2‐4.
  • Switch plate on/off with service code to ensure it is responding to cabinet circuits.
  • With plate on and calling for heat, check amp draw on leads between distribution board and heater plate. Amp draw on a properly functioning plate should be 1.67.

Call service top row temp

Call service bot row temp

Call service top row temp

Call service bot row temp

RTD sensor is producing a reading that is out of range. The problem can be a failed RTD, heater or distribution board.

Call service top sensor

Call service bot sensor

Call service top sensor

error low temp **

Call service bot sensor

error low temp** * Shown on master control display. ** Shown on affected row display.

Show 6 more labels / short text on this page
too high ** · too high** · too cool** · too cool ** · error hi temp** · error hi temp**
Page 18 of the Frymaster UHC-HD user manual — Symptom Possible Causes Tests
Page 18 · click to enlarge
Page 18

Cabinet Troubleshooting

Failure modes not accompanied by a master control display are shown below with possible causes and tests.

Symptom Possible Causes Tests

  • No power to cord.
  • Blown 20 amp fuse.
  • Circuit breaker open.

Unit fails to power up; fans don’t run.

  • Check for line voltage at the switch and the transformer.
  • Reset circuit breaker.

Unit powers up and fans run; a display fails to light.

  • Broken or improperly seated ribbon cable.
  • Defective display.
  • Switch ribbon cable from functioning display to failed component to isolate problem.
  • Unit powers up and fans run; all displays fail to light.
  • Failed power supply.
  • Check for 5VDC at communication board and distribution boards.
  • Ensure heater leads and power inputs on the distribution boards are properly seated.
  • Test for 208VAC input on distribution board and 208VAC output from heater leads to heater plate when the unit is calling for heat.
  • Switch power leads from properly operating row to faulty row to isolate problem.
  • Check resistance of RTD lead against temperature chart. See Page 2-4.
  • Switch RTD lead from properly operating row to faulty row to isolate problem.
  • Test continuity of heater plate.
  • Improper wiring on distribution board.
  • Defective distribution board.
  • Defective heater.
  • Defective sensor.

Rows heat improperly or not at all.

Page 19 of the Frymaster UHC-HD user manual — Cabinet Parts
Page 19 · click to enlarge
Page 19

Cabinet Parts

Frymaster UHC-HD — Cabinet Parts diagram (page 19)
Fig. 53 · Cabinet Parts
Frymaster UHC-HD — Cabinet Parts diagram (page 19)
Fig. 54 · Cabinet Parts

1 108-1897 Top Cap 2 823-7636 Rear Fascia 3 807-4882 Circuit Breaker, 16 amp 4 807-5111 Time/Temperature switch 5 807-4911 Power switch 6 823-7513 Front fascia 7 807-5112 Master control overlay with ribbon cable * 807-5156 Master display board (circuit board in master display assembly)

Page 20 of the Frymaster UHC-HD user manual — Cabinet Parts
Page 20 · click to enlarge
Page 20

Cabinet Parts

Frymaster UHC-HD — Cabinet Parts diagram (page 20)
Fig. 55 · Cabinet Parts

8 807-5111 Time/Temperature switch 9 826-2781 Bezel, with boards, front with short ribbon cable * 826-2782 Bezel with boards, rear, with long ribbon cable 10 108-1190 Base 11 807-4857 Heater plate/RTD 12 807-4860 Distribution board 13 108-1633 Side, left, vented 14 108-1632 Side right, not vented Component Shelf

Frymaster UHC-HD — Cabinet Parts diagram (page 20)
Fig. 56 · Cabinet Parts
Frymaster UHC-HD — Cabinet Parts diagram (page 20)
Fig. 57 · Cabinet Parts

15 807-5150 Master control board 16 807-2665 Blower 17 807-4951 LON board, domestic * 807-4952 LON board, international

Page 21 of the Frymaster UHC-HD user manual — Cabinet Parts
Page 21 · click to enlarge
Page 21

Cabinet Parts

Item Part Number Description

18 807-4868 Power Supply 19 807-3490 Power relay 20 406-0011 UHC-HD Single Filter Board * Ribbon Cables

* 807-4916 Time/Temp 18” used for front fascia * 807-4917 Time/Temp 32” used for rear fascia * 807-4875 Master distribution * 807-4922 Power to upper distribution board * 807-4923 Power to lower distribution board

*Not Illustrated

Page 22 of the Frymaster UHC-HD user manual — Cabinet Wiring Diagrams
Page 22 · click to enlarge
Page 22

Cabinet Wiring Diagrams

Wiring Diagram, Delta Power, L1-L2

Frymaster UHC-HD — Cabinet Wiring Diagrams diagram (page 22)
Fig. 58 · Cabinet Wiring Diagrams
Page 23 of the Frymaster UHC-HD user manual — Cabinet Wiring Diagrams
Page 23 · click to enlarge
Page 23

Cabinet Wiring Diagrams

UHC-HD, WYE Power, L1-N

Frymaster UHC-HD — Cabinet Wiring Diagrams diagram (page 23)
Fig. 59 · Cabinet Wiring Diagrams
Page 24 of the Frymaster UHC-HD user manual — 819-6606 OCT 2010
Page 24 · click to enlarge
Page 24
Frymaster UHC-HD — PRINTED IN THE UNITED STATES SERVICE HOTLINE diagram (page 24)
Fig. 60
Frymaster UHC-HD — PRINTED IN THE UNITED STATES SERVICE HOTLINE diagram (page 24)
Fig. 61

Frymaster, L.L.C., 8700 Line Avenue, Shreveport, Louisiana 71106

TEL 1-318-865-1711 FAX (Parts) 1-318-219-7140 FAX (Tech Support) 1-318-219-7135

PRINTED IN THE UNITED STATES SERVICE HOTLINE

Price$6.00

819-6606 OCT 2010

1-800-551-8633

Fix-it

Troubleshooting

Common problems, likely causes, and what to do.

ProblemPossible causeRemedy
Unit fails to power up; fans don’t run.• No power to cord. • Blown 20 amp fuse. • Circuit breaker open. p.18
Unit powers up and fans run; a display fails to light.• Broken or improperly seated ribbon cable. • Defective display. p.18
Unit powers up and fans run; all displays fail to light.• Failed power supply. p.18
Rows heat improperly or not at all.• Improper wiring on distribution board. • Defective distribution board. • Defective heater. • Defective sensor. p.18

Ask about the Frymaster UHC-HD

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Frymaster UHC-HD

Be the first to ask — other owners or our team will answer.

Original document

Frymaster UHC-HD manual PDF

24 pages·1.3 MB·Fryer·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…