Frymaster, a member of the Commercial Food Equipment Service Association, recommends using CFESA Certified Technicians. *8196606* 24-Hour Service Hotline 1-800-551-8633

NOTICE IF, DURING THE WARRANTY PERIOD, THE CUSTOMER USES A PART FOR THIS ENODIS EQUIPMENT OTHER THAN AN UNMODIFIED NEW OR RECYCLED PART PURCHASED DIRECTLY FROM FRYMASTER DEAN, OR ANY OF ITS AUTHORIZED SERVICE CENTERS, AND/OR THE PART BEING USED IS MODIFIED FROM ITS ORIGINAL CONFIGURATION, THIS WARRANTY WILL BE VOID. FURTHER, FRYMASTER DEAN AND ITS AFFILIATES WILL NOT BE LIABLE FOR ANY CLAIMS, DAMAGES OR EXPENSES INCURRED BY THE CUSTOMER WHICH ARISE DIRECTLY OR INDIRECTLY, IN WHOLE OR IN PART, DUE TO THE INSTALLATION OF ANY MODIFIED PART AND/OR PART RECEIVED FROM AN UNAUTHORIZED SERVICE CENTER.
THE CABINET IS NOT SUITABLE FOR OUTDOOR USE. WHEN OPERATING THIS UNIT, IT
MUST BE PLACED ON A HORIZONTAL SURFACE.
THE CABINET IS NOT SUITABLE FOR INSTALLATION IN AN AREA WHERE A WATER JET
CAN BE USED. THIS APPLIANCE MUST NOT BE CLEANED WITH A WATER JET.
FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN
THE VICINITY OF THIS OR ANY OTHER APPLIANCE.
DO NOT OPERATE OR SERVICE THE CABINET WITHOUT FIRST READING THIS MANUAL.
CHECKED.
DO NOT OPERATE THE CABINET UNLESS ALL SERVICE AND ACCESS PANELS ARE IN
PLACE AND PROPERLY SECURED.
DO NOT ATTEMPT TO REPAIR OR REPLACE ANY COMPONENT OF THE CABINET UNLESS
ALL POWER TO THE UNIT HAS BEEN DISCONNECTED.
CONTACT WITH HEATED SURFACES.
USE CAUTION WHEN LIFTING THE UHC-D. THE UNIT WEIGHS 200 POUNDS. THREE TO FOUR PEOPLE, USING STANDARD SAFE LIFTING PRACTICES, WILL BE NECESSARY TO
HANDLE THE CABINET.




Distribution boards shown with ribbon cables removed.



Upon startup, the cabinet beeps. LED’s on the distribution boards flash. The displays show the version number of the cabinet’s firmware and then the row’s status.

2 Service Procedures DANGER: Failure to disconnect power from the unit before servicing could result in serious injury or death. The cabinet power switch DOES NOT disconnect all incoming power to the cabinet. 2.1 Updating Software/Capturing Configurations The five sections of software on the cabinet can be updated individually. To ensure compatibility between cabinet software and replacement boards, the software should be updated to the latest version at any board replacement. Follow the directions below. Software updates use the master control display to enter programming codes, scroll to areas to be revised, respond to questions and exit. The control is annotated above. The arrow and OK buttons are illuminated when active. Check Existing Versions




Fig. 2: Tabs in the topcap extend to holes in the cabinet. The top is secured with at the tabs with screws.

Fig. 1: The sides are held in place by screws near the base of the unit on each side.


Power Switch: Cycle power between each revision update.
OK: Press to confirm choices.
Arrows: Scroll to choices.
Programming key: Press prior to entering programming code.
d

Loading Sequence Software should be loaded in this sequence:
1. Turn power off. 2. Insert flash drive in USB port located on cabinet bezel. 3. Turn power on. 4. Cabinet displays version numbers followed by current menu setting. 5. Press programming key. 6. Screen scrolls Enter Access Sequence. 7. Enter 98765 with keypad. 8. Press OK. 9. Scroll with arrow key until software section (see loading sequence box) to be updated is displayed on master control board. 10. Press OK. 11. Screen displays Copying Files, Please Wait. This takes several minutes. 12. Screen messages will vary, depending on software section being installed. Follow screen instructions. 13. Screen displays Complete. 14. Press OK. 15. Screen displays Main Boot Loading and a percentage of completion. 16. After 100% is displayed, screen goes blank and returns to menu display. 17. Turn cabinet off for 30 seconds and back on. Update: Language File
Incompatibility Message The cabinet can display an incompatibility message during software upgrades. The buttons will remain active. Follow the loading sequence and the incompatibility is corrected as the software components are loaded.
1. With the unit on, press program button. 2. Enter 090709 with the keypad. 3. Press OK. 4. Screen displays Reconfigure OK or Cancel. 5. Press OK. 6. Screen displays Please Wait Lang Bin. 7. Screen displays 9 files copied. 8. Press OK. 9. Screen returns to normal display. 10. Turn cabinet off for 30 seconds and back on. Capture Cabinet Menus/Configurations The menu items and cabinet configurations in a cabinet can be captured and used to configure cabinets with identical software setups. Follow the instructions below to capture the menus and configuration from a cabinet.


The configuration of a cabinet can be captured on an empty flash drive for transfer to cabinets with the same software setup.

USB. 6. Press OK. 7. The master control displays Please Wait… as files are transferred to the flash drive, changing to the number of files copied when the process is complete. 8. Press OK. 9. Remove flash drive. 10. Cabinet returns to normal display. Configure Cabinet with Menu/Configuration Captured on another Cabinet


A cabinet configuration can be transferred to multiple cabinets with a captured configuration held on a flash drive.

2.2 Placing the cabinet in Service Mode The cabinet can be put in service mode, a diagnostic settings which allows the heater plates to be controlled individually, brightness settings on the displays adjusted and re-addressing for unique arrangements of bezels. Follow the steps below : Switching Heater Plates Off Individually When troubleshooting, it may be useful to switch heater plates off individually. Follow the instructions below:

1. Press the programming key. 2. Enter 1111 at the Enter Access Sequence prompt. 3. The screen will scroll Row 1 Top Heater Off; pressing OK turns it back on. 4. Voltage can be measured between the plate-specific heater leads on the distribution board and the common block to the right of the distribution board as the heater plates are switched, individually, on and off. 5. Scroll to other plates with WX. 6. Ensure the plates are on before backing out of the Service Mode with the /. Adjusting Display Brightness When multiple row positions are timing the same item, the display with the least remaining time is the brightest. All others are dimmer as are positions not actively timing a product. The relative brightness of the bright display and the dim display can be adjusted. Follow the instructions below:
1. Press the programming key. 2. Enter 1111 at the Enter Access Sequence prompt. 3. Press OK. 4. The screen will scroll Row 1 Top Heater Off. 5. Scroll with X through all the Heater Plate prompts until the screen displays Press OK to Adjust Bright Row Display. 6. Press OK. 7. The cabinet’s row displays become Decrease Increase 88888 20 8. Press the timer button next to the Decrease display to lessen the brightness; the number displayed at the right will decrease. Press the timer button next to the Increase display to increase the brightness; 20 is the maximum. 9. Press OK. The display becomes Adjust Dim Intensity. The cabinet’s row displays become Decrease Increase 88888 03 10. Press the timer button next to the Decrease display to lessen the brightness; the number displayed at the right will decrease. Press the timer button next to the Increase display to increase the brightness; 1 is the minimum. 11. Press OK. 12. Cabinet returns to menu display.

Readdressing the Cabinet Addressing, or assigning a position-specific component such as a display or distribution board, is done automatically by the cabinet on startup. Communication errors can occur on start-up after a board installation however. If so, follow the instructions below to readdress the cabinet. This process can also be used during troubleshooting when displays are connected out of synch with their associated bezel on the same row level.

2.3 Accessing the Electronic Components 1. The component shelf is accessed by removing two screws on each side of the unit (Fig. 1). 2. Lift and remove the sides, which exposes screws that hold the top in place (Fig. 2). 3. The components are annotated below (Fig. 3). All the components are readily removed. There are no replaceable components on the circuit boards.

Fans: are specific to regions of the cabinet and ducted to direct the air flow.
Master Control Board LON board










suspect heater. Note: Line voltage is only seen when the row is calling for heat. 2. Check for line voltage between the power input terminal and the terminal block. 3. Check for +5VDC at the power-in terminal and the terminal block for the power supply. NOTE: After testing, reconnect all connections to their original positions. 2.5.4 Display 1. Remove power from unit. 2. Connect the ribbon cable from a suspect display to the connector of a properly working display to isolate the problem to the display or the distribution board. 3. Reapply power to cabinet. 2.5.5 Shorted Triac 1. Turn the suspect row off and measure voltage between the suspect heater lead on the distribution board and the terminal block. With the row off, there should be no line voltage. If the triac is shorted, you will measure AC line voltage. If the triac is half waving, you will get DC voltage of approximately one-half the line AC voltage.




Fig. 6: Distribution board shown with display cables removed.
2.5.6 Heater Plate 1. Disconnect power to the cabinet. Remove side and top panels. Disconnect the black heater lead and the RTD leads (brown and red) of the suspect plate from distribution board. Measure resistance of the heater from the black lead to any terminal on the white terminal block. Resistance should be 140-150 ohms.
2.5.7 Display Meanings 1. ROW TEMP HIGH OR ROW TEMP LOW and no audible alarm. This is normal when the row is changing temperature in association with a menu change.




1. Remove power from unit. 2. Remove screws at the base of each side and remove side panels. (See figure 7.) 3. Unplug the bezel from the distribution board. 4. Plug the replacement bezel into the distribution board, return power to the unit and test the bezel/cabinet for accurate operation. 5. Remove replacement bezel and remove power from the unit. 6. Loosen the hex nut which secures the row and remove the allen screw, which holds the bezel. Also remove, if present, the small bezel-securing screw. (See photo below.) 7. Push, if necessary, on the mounted bezel through the access port in the inner panel to loosen the bezel. (See Figure 8 below.) 8. Remove bezel; clean and degrease the groove in the heater plate. 9. Route ribbon cable for the new bezel through the inner panel of the cabinet and press the new bezel into place. Ensure it is firmly seated and tighten hex nuts and replace allen screws. 10. Return sides and reposition cabinet for operation.

Fig. 7: Two screws (see arrows) at the base of each side of the cabinet secure the sides.






Fig. 8: Loosen the hex bolt and remove the allen screw (arrows, upper photo). Some row positions may have an additional screw securing the bezel to the cabinet (lower photo). Push through the access port (arrow, upper photo), if necessary, to remove the bezel from the cabinet .






Fig. 9: A row is shown partially removed from the cabinet.

Fig. 10, 11: Find the set screws under the foil insulation and push through with an allen wrench.


Fig. 12: The heater plate slides from the insulation.
Tightening the setscrews will ensure the plate is properly grounded.

The master control display and the row displays show error messages when there is a problem. The messages are shown in the matrix below along with possible causes and diagnostic tests.
Error Message Cause Tests Call service row display error Row number also displayed *
The master control board has lost communication with the specified board.
The master control board has lost communication with the top distribution board.
The master control board has lost communication with the bottom distribution board.
Call service distribution board 1 error*
Row’s top plate failed to reach required temperature in prescribed time window after startup or when switching between menus.
Call service rate of rise top**
Row’s bottom plate failed to reach required temperature in prescribed time window after startup or when switching between menus.
Call service rate of rise bot **
Call service top row temp
Call service bot row temp
Call service top row temp
Call service bot row temp
RTD sensor is producing a reading that is out of range. The problem can be a failed RTD, heater or distribution board.
Call service top sensor
Call service bot sensor
Call service top sensor
error low temp **
Call service bot sensor
error low temp** * Shown on master control display. ** Shown on affected row display.

Failure modes not accompanied by a master control display are shown below with possible causes and tests.
Unit fails to power up; fans don’t run.
Unit powers up and fans run; a display fails to light.
Rows heat improperly or not at all.



1 108-1897 Top Cap 2 823-7636 Rear Fascia 3 807-4882 Circuit Breaker, 16 amp 4 807-5111 Time/Temperature switch 5 807-4911 Power switch 6 823-7513 Front fascia 7 807-5112 Master control overlay with ribbon cable * 807-5156 Master display board (circuit board in master display assembly)


8 807-5111 Time/Temperature switch 9 826-2781 Bezel, with boards, front with short ribbon cable * 826-2782 Bezel with boards, rear, with long ribbon cable 10 108-1190 Base 11 807-4857 Heater plate/RTD 12 807-4860 Distribution board 13 108-1633 Side, left, vented 14 108-1632 Side right, not vented Component Shelf


15 807-5150 Master control board 16 807-2665 Blower 17 807-4951 LON board, domestic * 807-4952 LON board, international

Item Part Number Description
18 807-4868 Power Supply 19 807-3490 Power relay 20 406-0011 UHC-HD Single Filter Board * Ribbon Cables
* 807-4916 Time/Temp 18” used for front fascia * 807-4917 Time/Temp 32” used for rear fascia * 807-4875 Master distribution * 807-4922 Power to upper distribution board * 807-4923 Power to lower distribution board
*Not Illustrated

Wiring Diagram, Delta Power, L1-L2


UHC-HD, WYE Power, L1-N




Frymaster, L.L.C., 8700 Line Avenue, Shreveport, Louisiana 71106
TEL 1-318-865-1711 FAX (Parts) 1-318-219-7140 FAX (Tech Support) 1-318-219-7135
1-800-551-8633
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| Unit fails to power up; fans don’t run. | • No power to cord. • Blown 20 amp fuse. • Circuit breaker open. | p.18 | |
| Unit powers up and fans run; a display fails to light. | • Broken or improperly seated ribbon cable. • Defective display. | p.18 | |
| Unit powers up and fans run; all displays fail to light. | • Failed power supply. | p.18 | |
| Rows heat improperly or not at all. | • Improper wiring on distribution board. • Defective distribution board. • Defective heater. • Defective sensor. | p.18 |
Owners and our team usually reply within a day — and your question helps the next person too.