Models SM20, SM35, SM40, SM50, SM60 & SM80

Dean, a member of the Commercial Food Equipment Service Association, recommends using CFESA Certified Technicians.

Please read all sections of this manual and retain for future reference.

personnel only. A Dean Factory Authorized Service Center (FASC) or other qualified professional should perform installation, maintenance, and repairs. Installation, maintenance,
or repairs by unqualified personnel may void the manufacturer’s warranty.

the country and/or region in which the appliance is installed. See NATIONAL CODE
REQUIREMENTS in Chapter 3 of this manual for specifics.
technical procedures and may not conform to onsite management operational procedures.

EQUIPMENT OTHER THAN AN UNMODIFIED NEW OR RECYCLED PART PURCHASED DIRECTLY FROM FRYMASTER/DEAN, OR ANY OF ITS AUTHORIZED SERVICE CENTERS, AND/OR THE PART BEING USED IS MODIFIED FROM ITS ORIGINAL CONFIGURATION, THIS WARRANTY WILL BE VOID. FURTHER, FRYMASTER/DEAN AND ITS AFFILIATES WILL NOT BE
LIABLE FOR ANY CLAIMS, DAMAGES OR EXPENSES INCURRED BY THE CUSTOMER WHICH
ARISE DIRECTLY OR INDIRECTLY, IN WHOLE OR IN PART, DUE TO THE INSTALLATION OF ANY MODIFIED PART AND/OR PART RECEIVED FROM AN UNAUTHORIZED SERVICE CENTER.

service instructions thoroughly before installing or servicing this equipment. Only qualified
service personnel may convert this appliance to use a gas other than that for which it was
originally configured.

anchor straps. All fryers equipped with casters must be stabilized by installing restraining chains. If a flexible gas line is used, an additional restraining cable must be connected at all

from slips or contact with the hot oil.
other cooking appliance.

company or gas supplier.

at the end of frying operations each day. Some food particles can spontaneously combust if left
soaking in certain shortening material. Additional information can be obtained in the filtration
manual included with the system.
the fryer under a hood. Questions? Call the Dean Service Hotline at 1-800-551-8633.

the strip, adversely affecting its fit. It is designed for a tight fit and should only be removed for
cleaning.

Safe and satisfactory operation of Dean equipment depends upon its proper installation. Installation MUST conform with local codes, or in the absence of local codes, to European
licensed plumber.





THIS PAGE INTENTIONALLY LEFT BLANK.

CHAPTER 1: INTRODUCTION
1.1 After Purchase In order to improve service, have the following chart filled in by the Dean Authorized Service Technician who installed this equipment.
Address Telephone/Fax Model Number Serial Number Gas Type 1.2 Ordering Parts Customers may order parts directly from their local Authorized Parts Distributor. For this address and phone number, contact your maintenance and repair center or call the factory. The factory address and phone numbers are on the back cover of this manual. To speed up your order, the following information is required:
Model Number Type Serial Number Optional Equipment Item Part Number Quantity Needed 1.3 Service Information Call the 1-800-551-8633 or (318) 865-1711 Service Hotline number for the location of your nearest maintenance and repair center. Always give the model and serial numbers of your fryer.
To assist you more efficiently, the following information will be needed:
Model Number Type Serial Number Optional Equipment Nature of Problem
Additional information (i.e. cooking environment, time of day, and other pertinent
information) may be helpful in solving your service problem.
Authorized Service Technician/FASC

CHAPTER 1: INTRODUCTION
1.4 Safety Information Before attempting to operate your unit, read the instructions in this manual thoroughly. Throughout this manual, you will find notations enclosed in double-bordered boxes similar to the ones below. CAUTION boxes contain information about actions or conditions that may cause or result in a malfunction of your system.
one container to another.

CHAPTER 1: INTRODUCTION
1.5.1 Definitions (cont.) B. Qualified Installation Personnel
1. Qualified service personnel are those who are familiar with Dean equipment and have been authorized by Dean to perform service on Dean equipment. All authorized service personnel are required to be equipped with a complete set of service parts manuals and stock a minimum amount of parts for Dean equipment. A list of Dean Factory Authorized Service Centers (FASCs) was included with the fryer when shipped from the factory. Failure to use qualified service personnel will void the Dean warranty on your equipment.

THIS PAGE INTENTIONALLY LEFT BLANK.

CHAPTER 2: IMPORTANT INFORMATION
A. Check that the container is upright. Use an outward prying motion - no hammering - to
remove the carton. Unpack the fryer carefully and remove all accessories from the carton. Do not discard or misplace these, as they will be needed.
B. After unpacking, immediately check the equipment for visible signs of shipping damage. If
damage has occurred, contact the carrier and file the appropriate freight claims. Do not contact the factory. Shipping damage responsibility is between the carrier and the dealer.
If your equipment arrives damaged:
C. Remove all plastic skin from sides, front, and doors of the fryer(s). Failure to do this prior to
initial fryer operation will make it very difficult to remove later. 2.2 General Qualified, licensed, and/or authorized installation or service personnel only (as defined in Section 1.5) should perform the following:

CHAPTER 2: IMPORTANT INFORMATION
2.2 General (cont.) Dean Super Marathon Series gas fryers are energy efficient, gas-fired units, design certified by (Approvals Pending), and manufactured to their basic performance and application specifications. All units are shipped completely assembled with accessories packed inside the frypots. All units are adjusted, tested and inspected at the factory before shipment. Sizes, weights and input rates of all models are listed in this manual.
the inherent dangers of operating a hot-oil fryer/filter system, particularly the
aspects of fryer operation, oil filtration, and draining/cleaning procedures. 2.3 Principles of Operation The incoming gas flows through orifices and is mixed with air in the burners to create the correct ratio for proper combustion. The mixture is ignited at the front end of each heat tube by the pilot light. Internal diffusers slow the flame as it goes through the burner tube. This slower and more turbulent flame gives much better heat transfer to the walls of the tubes, thereby heating the oil more efficiently. 2.4 Rating Plate
This is attached to the inside front door panel. Information provided includes the model and serial number of the fryer, BTU/hr input of the burners, outlet gas pressure in inches W.C. and whether the unit has natural or propane gas orifices.
plate.

CHAPTER 2: IMPORTANT INFORMATION
2.5 Pre-Installation
Hotline at 1-800-551-8633.
this chapter. A. General: Only licensed personnel should install any gas-fired equipment.
certified for the following installations:
beside an open flame of any type, including those of broilers and ranges.

CHAPTER 2: IMPORTANT INFORMATION
2.5 Pre-Installation (cont.) C. Installation Standards
American National Standard Institute CAN 1-B149 Installation Codes ANSI Z83.11 Canadian Gas Association American Gas Association 55 Scarsdale Road 8501 E. Pleasant Valley Road Don Mills, ONT, M3B 2R3 Cleveland, OH 44131 National Electrical Code Canadian Electric Code c22.1, part 1 ANSI/NFPA #70 Canadian Standards Association American National Standard Institute 178 Rexdale Blvd. 1430 Broadway Rexdale, ONT, M9W 1R3 New York, NY 10018 NFPA Standards #96 and #211 National Fire Protection Association 470 Atlantic Avenue Boston, MA 02110
D. Australian Requirements To be installed in accordance with AS 5601 / AG 601, local authority, gas, electricity, and any other relevant statutory regulations. 2.6 Equipment Installed at High Altitudes 1. The fryer input rating [BTU/hr (kW/hr)] is for elevations up to 2,000 feet (610-m). For elevations above 2,000 feet (610-m), the rating should be reduced 4-percent for each additional 1,000 feet (305-m) above sea level. 2. The correct orifices are installed at the factory if the operating altitude is known at the time of the customer’s order.

CHAPTER 2: IMPORTANT INFORMATION
2.7 Air Supply and Ventilation
of unacceptable concentrations of substances harmful to the health of personnel in
the room in which it is installed. 2.7 Air Supply and Ventilation (cont.) Keep the area around the fryer clear to prevent obstruction of combustion and ventilation airflow. 1. Do not connect this fryer to an exhaust duct. 2. Correct installation and adjustment will ensure adequate airflow to the fryer system. 3. A commercial, heavy-duty fryer must vent its combustion wastes to the outside of the building. A deep-fat fryer must be installed under a powered exhaust hood, or an exhaust fan must be provided in the wall above the unit, as exhaust gas temperatures are approximately 800-1000°F (427-538°C). Check air movement during installation. Strong exhaust fans in the exhaust hood or in the overall air conditioning system can produce slight air drafts in the room. 4. Do not place the fryer’s flue outlet directly into the plenum of the hood, as it will affect the gas combustion of the fryer. 5. Never use the interior of the fryer cabinet for storage or store items on shelving over or behind the fryer. Exhaust temperatures can exceed 800°F (427ºC) and may damage or melt items stored in or near the fryer. 6. Adequate distance must be maintained from the flue outlet of the fryer(s) to the lower edge of the filter bank. Per NFPA Standards No. 96, a minimum of 18-inches (45-cm) should be maintained between the flue(s) and the lower edge of the exhaust hood filter. 7. Filters and drip troughs should be part of any industrial hood, but consult local codes before constructing and installing any hood. The duct system, the exhaust hood and the filter bank must be cleaned on a regular basis and kept free of grease.

THIS PAGE INTENTIONALLY LEFT BLANK.

3.1 Installing the Fryer A. Initial Installation: If installed with legs, do not push against the fryer’s side to adjust its
position. Use a pallet or lift jack to lift the fryer slightly and place it where it is to be installed. B. Relocating the Fryer: If relocating a fryer installed with legs, remove all weight from each leg
repair/replacement.


must be removed from the fryer before attempting to move it to avoid oil spills, and
the falls and severe burns that could occur. This fryer may tip and cause personal
injury if not secured in a stationary position. 3.2 Leg and Caster Installation

a moveable or portable installation, Dean optional equipment casters must be used.
Questions? Call 1-800-551-8633. A. General

3.2 Leg and Caster Installation (cont.)
fryer is off level side to side, a platform or other surface adjustment is needed; there is no side- to-side level adjustments on a fryer equipped with caster/leg combinations. (If a fryer is equipped with legs only, side-to-side level adjustments can be made. If a fryer is equipped with casters only, no level adjustments to the fryer can be made.). If the fryer is not level, the unit may not function efficiently, the oil may not drain properly for filtering and in a multi-fryer battery, it may not match adjacent units.
Legs (Only) · Rigid Casters (Only)

3.3 Leveling the Fryer (cont.) B. If the floor is uneven or has a decided slope, place the fryer on a smooth, level platform.
C. If the fryer is moved, re-level the fryer following the instructions given in Steps 3.3, A-C.
D. An installed fryer must be restrained to prevent tipping, which could splash hot oil. Restraints
can be straps or chains anchored to an immovable object (wall, floor anchor), or the manner of installation (installing the fryer in an alcove, battering to other appliances, etc.).

before installing the casters. E. Installing Optional Swivel Casters:


3.3 Leveling the Fryer (cont.) NOTE: The installation must be inspected after it is complete to ensure it meets the intent of these instructions. The on-site supervisor and/or operator(s) should be informed that the appliance is installed with restraints. If restraints are removed to move fryer (cleaning beneath and behind, relocation, etc.), ensure that they are re-installed when fryer is returned to its permanently installed position.

plate located on the back of the fryer door.

local gas company or FASC should be contacted immediately to rectify the problem. 3.4 Gas Connections

to remove all foreign material. Foreign material in the burner and gas controls will
NATIONAL CODE REQUIREMENTS This equipment is to be installed in compliance with the Basic Plumbing Code of the Building Officials and Code Administrators International, Inc. (BOCA) and the Food Service Sanitation Manual of the U.S. Food and Drug Administration. This equipment is manufactured to use the type of gas specified on the rating plate attached to the door. Connect equipment stamped "NAT" only to natural gas and that stamped "PRO" only to LP (Propane) gas.
Installation shall be made with a gas connector that complies with national and local codes.
Quick disconnect devices, if used, shall likewise comply with national and local codes.

plate located on the back of the fryer door.

3.4 Gas Connections (cont.) The gas supply (service) line must be the same size or greater than the fryer inlet line. Super Marathon and Super Runner Series gas fryers are equipped with a 3/4" (22 mm) male ISO 7.1 inlet. The gas supply line must be sized to accommodate all gas-fired equipment connected to that gas supply. Consult local gas companies or suppliers, or your local contractor for minimum supply line requirements. Supply Line Specifications The gas supply lines must be sized as indicated in the chart below, based on the total number of fryers connected to the main gas supply.

Recommended Gas Supply Line Sizes Gas Types Number of Fryers 1 2 to 3 4 or more (*) Natural Gas 3/4" (22 mm) 1" (28 mm) 1-1/4" (35 mm) Propane Gas 1/2" (15 mm) 3/4" (22 mm) 1" (28 mm) (*) When exceeding 18 feet (6 meters) for a configuration of more than four fryers, it is necessary
to provide a 1 1/4" (35 mm) rigid gas connection.

used and all connections must be tested with a solution of soapy water before
Never use matches, candles, or any other ignition source to check for leaks. If gas
odors are detected, shut off the gas supply to the appliance at the main shut-off
valve and immediately contact the local gas company or an authorized service
agency for service.

unit.

3.4 Gas Connections (cont.) Rigid Connections Check any installer-supplied intake pipe(s) visually and clean metal particles or other foreign matter from the threads before installing into a service line. If the intake pipes are not clear of all foreign matter, the orifices will clog when gas pressure is applied. When using thread compound on gas piping, use very small amounts and only on male threads. Use a pipe thread compound that is not affected by the chemical action of LP gases. DO NOT apply thread compound to the first two pipe threads – doing so will cause clogging of the burner orifices and control valve. Manual shut-off valve This gas service supplier-installed valve must be installed in the gas service line ahead of the fryers in the gas stream and in a position where it can be reached quickly in the event of an emergency. Regulating Gas Pressure The fryer and shut-off valve must be disconnected from the gas supply during any pressure testing of the system. External gas regulators are not normally required on this fryer. A safety control valve protects the fryer against pressure fluctuations. If the incoming pressure is in excess of ½" PSI (3.45 kPa/35 mbar), a step-down regulator will be required.
line if the test pressure is ½" PSI [3.45 kPa (14 inches W.C.)] or greater to avoid
damage to the fryer’s gas piping and gas valve(s).
manometer.

new connections.
unless the regulator is out of adjustment, or serious pressure fluctuations are observed.
C. Only qualified service personnel should make adjustments to the regulators.
control valve, appropriate gas orifices, and pilot burner are installed at the factory. While the valve can be adjusted in the field, only qualified service personnel should make any adjustments with the proper test equipment.
E. Flexible Couplings, Connectors and Casters
Personal injury may result.

F. After hook up, bleed the gas line of air to ensure that the pilot light will ignite quickly and
evenly.
if required. Failure to use qualified personnel will void the Dean warranty. 3.5 Adjustments/Adaptation To Different Gases
A. Proper operation of appliances requires operator to scrupulously inspect the following
adjustments in terms of gas inputs and pressures.
B. Dean Super Marathon and Super Runner Series gas fryers are manufactured to use the type
of gas and pressure specified on the rating plate. When changing gas, adaptation must be performed by qualified personnel. Failure to use qualified personnel will void the Dean warranty.
from one gas type to another requires the installation of specific gas-conversion
components.
Switching to a different type of gas without installing the proper conversion components may result in fire or explosion. NEVER ATTACH THIS APPLIANCE TO A
Conversion of this appliance from one type of gas to another should only be performed by qualified, licensed, and authorized installation or service personnel, as
defined in Section 1.5 of this manual.

3.6 Gas Inputs Nominal Heat Inputs (Qn), Gas Type, Orifice Size (applicable for fryer operation at altitudes of 2000 feet or less), Part Number and Quantity are listed in the table below:

* Use these orifices on SR42 fryers built after 4/07. ** Use these orifices for Australian units.
A. Adjustments for different gases are as follows:

Gas Supply Pressure* 4" W.C. (10 mbars) 11" W.C. (27.5 mbars)
Gas pressure at the regulator [Inches W.C. (mbar)]* 4" W.C. (10 mbars) 11" W.C. (27.5 mbars)

3.7 Gas Conversion Procedures See gas valve illustration below and gas valve, burner and orifice location on page 3-11 when performing the following conversions. When converting from natural gas to propane (or vice-versa), the following procedures apply:
♦ Burner orifices and pilot orifice MUST be replaced (See page 3-9 for required component part numbers). ♦ Adjust orifice gas pressure by turning the gas-valve adjustment screw (See page 3-9 for various gas types and pressures). ♦ After adjustment, replace the adjustment-screw cover. ♦ Affix the new label included with the conversion kit next to the exiting rating plate stating that the gas type has been converted. Remove any references to the previously used gas from the existing rating plate. Conversion from one gas family to another (i.e. changing from natural gas to propane) requires special components. Obtain the necessary components using the tables on page 3-9. Conversions can only be executed by qualified, factory-authorized personnel.

Pressure flow adjustment (remove cover screw to access)
Regulator Vent Pilot pressure adjustment (remove cover screw to access)
Pilot gas supply connection
Typical gas valve (Millivolt- Non-CE).
ON/PILOT/OFF Gas-Cock Knob · Pressure Tap


3.8 Gas Conversion Components Use the following components to convert from natural gas to propane and vice-versa. See Section 3.6 for orifice quantities required for conversion.
Typical gas valve, burner and orifice locations (SM50 shown above).

Natural Gas to Propane Kit, 826-1817 Propane To Natural Gas Kit, 826-2017
Bushing, NPT Flush, SR 42 Series only Bushing, NPT Flush, SR 42 Series only
* Burner orifices listed on page 3-9 are for fryers operating at altitudes of 2000 feet or less. For altitudes greater than 2000 feet, contact the factory for the correct orifice size.

3.9 Electrical Connections Fryers without built-in filtration do not require electrical connection. Fryer systems with built-in filtration when installed must be electrically grounded in accordance with local codes, or in the absence of local codes, with the appropriate national standards.
plug for protection against shock hazard. It should be plugged directly into a
properly grounded, three-prong receptacle. DO NOT CUT, REMOVE, OR
OTHERWISE BYPASS THE GROUNDING PRONG ON THIS PLUG. For fryers with built-in filtration systems: The rating plate and wiring diagram are located on the inside front door panel. Built-in filtration systems are equipped with 120VAC single-phase 60-hertz system (Domestic), or 230VAC single-phase 50-hertz system (International/CE). Do not cut or remove the ground prong from the power cord plug.
power outage. Do not attempt to operate this appliance during a power outage.

CHAPTER 4: FRYER OPERATIONS

the inherent hazards of operating a hot oil frying system, particularly the aspects of
system operation, oil filtration, draining and cleaning procedures. Cleaning: New units are wiped clean with solvents at the factory to remove any visible signs of dirt, oil, grease, etc. remaining from the manufacturing process, then coated lightly with oil. Before any food preparation, wash thoroughly with hot, soapy water to remove any film residue and dust or debris then rinse out and wipe dry. Also wash any accessories shipped with the unit. Close the drain valve completely and remove the crumb screen covering the heating tubes. Ensure the screws holding the thermostat and high-limit control sensing bulbs into the frypot are tight.

Typical high-limit/sensor probe location and mounting hardware.

a tight fit and should only be removed for cleaning.

water or cooking oil/shortening before lighting the burners. Failure to do so will
damage the frypot and may cause a fire.


CHAPTER 4: FRYER OPERATIONS
4.1.1 Pilot Lighting Procedures, Standing Pilot Only Initial Pilot Lighting: All Dean fryers are tested, adjusted and calibrated to sea level conditions before leaving the factory. Adjustments to assure proper operation of pilot may be necessary on installation to meet local conditions, low gas pressure, differences in altitude and variations in gas characteristics. These adjustments correct possible problems caused by rough handling or vibration during shipment, and are to be performed only by qualified service personnel. These adjustments are the responsibility of the customer and/or the dealer and are not covered by the Dean warranty. The inlet pipe at the lower rear of the fryer brings incoming gas to the pilot safety control valve, then to the pilot and main burners. The pilot is located high in the cabinet center, at the base of the frypot. Light the pilot as follows:

CHAPTER 4: FRYER OPERATIONS
4.2 Boil-Out Procedure

boils over, turn the fryer off immediately and let the solution cool for a few minutes before resuming the process. To lessen the chance of boil over, turn the fryer’s gas
valve knob to the PILOT position occasionally.

or a portable filter unit. These units are not intended for this purpose, and will be
damaged by the solution.

shortening is heated to cooking temperature and may cause injury to nearby
personnel. 4.2.1 Thermostat-Equipped Fryers
A. Pour cleaning solution into the frypot and add water to the bottom OIL LEVEL line scribed
in the back of the frypot.
B. Set the operating thermostat dial/temperature controller to 225°F (107ºC), just above that of
boiling water.
C. The main burner will ignite.
D. When the solution nears boiling point, reset the temperature controller to 200°(93ºC).
E. The burners should shut off just as the water starts to boil.
F. The burners will heat the boil-out solution to a simmer. Simmer the solution for
approximately 45 minutes. Wearing protective gloves, scrub the sides of the frypot and the tubes with the L-shaped Teflon brush, being careful not to disturb the temperature sensing probes and the high-limit thermostat.
G. Do not allow the water level to decrease below the bottom OIL LEVEL line in frypot during
boil-out operation.


CHAPTER 5: PREVENTATIVE MAINTENANCE

cooking temperature, it will cause spattering of the oil/shortening, which can result
Any equipment works better and lasts longer when maintained properly and kept clean. Cooking equipment is no exception. Dean millivolt gas fryers should be kept clean during the working day and thoroughly cleaned at the end of each day. Below are recommendations for daily, weekly and periodic preventative maintenance.
5.1.1 Daily

of time the cleaner remains on the food-contact surfaces.
A. Remove and wash all removable parts.
B. Clean all exterior surfaces of the cabinet. Do not use cleaners, steel wool, or any other
abrasive material on stainless steel.
C. Filter the cooking oil and replace if necessary. The oil should be filtered more frequently
when under heavy use. 5.1.2 Weekly
A. Completely drain the oil from the fryer into a metal stockpot of sufficient size to safely hold
the entire contents of the frypot for disposal. Do not use a glass or plastic container.
B. Clean the frypot by following boil-out procedures in Chapter 4-2.

result.

CHAPTER 5: PREVENTATIVE MAINTENANCE
burns. All stainless steel fryer cabinet parts should be wiped regularly with hot, soapy water during the day, and with a liquid cleanser designed for stainless steel at the end of each day.
A. Do not use steel wool, abrasive cloths, cleansers or powders.
B. Do not use a metal knife, spatula or any other metal tool to scrape stainless steel! Scratches
are almost impossible to remove.
C. If it is necessary to scrape the stainless steel to remove any encrusted materials, soak the area
first to soften the deposit, then use a wood or nylon scraper only.

CHAPTER 6: TROUBLESHOOTING
appliance when filled with hot cooking oil/shortening or to transfer hot cooking
oil/shortening from one container to another. The problems and possible solutions covered are those most commonly encountered. To troubleshoot, perform the test set-up at the beginning of each condition. Follow each step in sequence. 6.2 Pilot Burner Malfunction
A. Pilot will not ignite; no evidence of gas at pilot burner.
B. Pilot burner ignites but will not remain lit when gas valve manual knob is released.
C. Pilot flame of proper size, but is unstable. Flame wavers and does not envelope the
thermocouple completely at all times.

CHAPTER 6: TROUBLESHOOTING
6.3 Main Burner Malfunctions
A. Main burner will not come "ON"; gas not detected at main burner.
B. Main burner flames are small and appear lazy; shortening does not come up to temperature
quickly.
C. Signs of excessive temperature; shortening scorches and quickly becomes discolored.
D. Fryer will not reach the temperature setting and/or runs erratically.
E. Fryer shortening temperature cannot be controlled; fryer runs at high-limit temperature.

CHAPTER 6: TROUBLESHOOTING
6.4 Wiring Diagrams
CONTROL CIRCUIT
Vent Valve Combination Gas
GENERATOR
PILOT ADJ.
1/2 P.S.I.
HONEYWELL 1/2 P.S.I.
ON
TH TP TH
1/2 P.S.I.
TP
OFF
N/O COM N/C
HI
THERMOPILE
LIMIT
THERMOSTAT OPERATING
Honeywell Millivolt Gas Valve Wiring
Robertshaw Millivolt Gas Valve Wiring
6.5 Recommended Spare Parts Commonly replaced parts in older Dean Millivolt gas (Non-CE) fryers are: Gas Valve (Honeywell)- Natural- 807-1603 Gas Valve (Honeywell)- LP- 807-1604 Gas Valve (Robertshaw)- Natural- 807-3645 Gas Valve (Robertshaw)- LP- 810-2399 High-limit Thermostat- 435°F Automatic Reset- 807-3516 High-limit Thermostat- 450°F Manual Reset- 807-3680 Thermopile- 810-2033 Thermostat, Operating- 807-3515 Knob, Thermostat- 816-0546


Dean, 8700 Line Avenue, PO Box 51000, Shreveport, Louisiana 71135-1000
TEL 1-318-865-1711 FAX (Parts) 1-318-327-3343 FAX (Tech Support) 1-318-219-7135
MAY 2007 PRINTED IN THE UNITED STATES SERVICE HOTLINE
1-800-551-8633 819-5895