Frymaster, a member of the Commercial Food Equipment Service Association, recommends using CFESA Certified Technicians.

CAUSE PROPERTY DAMAGE, INJURY, OR DEATH. READ THE INSTALLATION, OPERATING,
AND SERVICE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS
EQUIPMENT.
VAPORS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.
USER SMELLS GAS. THIS INFORMATION SHALL BE OBTAINED BY CONSULTING THE LOCAL
GAS SUPPLIER.
THIS EQUIPMENT IS TO BE INSTALLED IN COMPLIANCE WITH THE BASIC PLUMBING CODE
OF THE BUILDING OFFICIALS AND CODE ADMINISTRATORS INTERNATIONAL, INC. (BOCA) AND THE FOOD SERVICE SANITATION MANUAL OF THE FOOD AND DRUG ADMINISTRATION.
FCC
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference, and 2) This device must accept
any interference received, including interference that may cause undesired operation. While
this device is a verified Class A device, it has been shown to meet the Class B limits.
This digital apparatus does not exceed the Class A or B limits for radio noise emissions as set
out by the ICES-003 standard of the Canadian Department of Communications.
Cet appareil numerique n’emet pas de bruits radioelectriques depassany les limites de classe A
et B prescrites dans la norme NMB-003 edictee par le Ministre des Communcations du Canada.
CANCER AND/OR BIRTH DEFECTS OR OTHER REPRODUCTIVE HARM. Operation, installation, and servicing of this product could expose you to airborne particles of glasswool or ceramic fibers, crystalline silica, and/or carbon monoxide. Inhalation of airborne
particles of glasswool or ceramic fibers is known to the State of California to cause cancer. Inhalation of carbon monoxide is known to the State of California to cause birth defects or other
reproductive harm.
FRYMASTER FRYERS EQUIPPED WITH LEGS ARE FOR PERMANENT INSTALLATION. FOR MOVEABLE OR PORTABLE INSTALLATION, FRYMASTER OPTIONAL EQUIPMENT CASTERS
MUST BE USED. QUESTIONS CALL 1-800-551-8633.



CHAPTER 1: GENERAL INFORMATION
RETAIN AND STORE THIS MANUAL IN A SAFE PLACE FOR FUTURE USE
1.1 Applicability and Validity
The GSMS/GBC/GC model family has been approved by the European Union for sale and installation in the following EU countries AT, BE, DE, DK, ES, FI, FR, GB, IE, IT, LU, NL, NO, PT, AND SE.
This manual is applicable to and valid for all GSMS/GBC/GC units sold in English-speaking countries, including those in the European Union. Where conflicts exist between instructions and information in this manual and local or national codes of the country in which the equipment is installed, installation and operation shall comply with those codes.
This appliance is only for professional use and shall be used by qualified personnel only, as defined in Section 1.7.
1.2 Parts Ordering and Service Information
In order to assist you quickly, the Frymaster Factory Authorized Service Center (FASC) or Service Department representative requires certain information about your equipment. Most of this information is printed on data plate affixed to the inside of the cooker door. Part numbers are found in the Installation, Operation, Service, and Parts Manual. Parts orders may be placed directly with your local FASC or distributor. A list of Frymaster FASCs was included with this equipment. If you do not have access to this list, contact the Frymaster Service Department at 1-800-551-8633 or 1-318-865-1711.
When ordering parts, the following information is required:
Service information may be obtained by contacting your local FASC/Distributor. Service may also be obtained by calling the Frymaster Service Department at 1-800-551-8633 or 1-318-865-1711. When requesting service, please have the following information ready:

In addition to the model number, serial number, and type of gas, please be prepared to describe the nature of the problem and have ready any other information that you think may be helpful in solving your problem. 1.3 Safety Information
Before attempting to operate your unit, read the instructions in this manual thoroughly.
Throughout this manual, you will find notations enclosed in double-bordered boxes similar to the one below.
1.4 European Union (EU) Specific Information
The European Union (EU) has established certain specific standards regarding equipment of this type. Equipment approved for use in EU countries is marked with the
symbol. Whenever a conflict exists between CE and non-CE standards or when CE-unique requirements exist, the information or instructions concerned are identified by means of shadowed boxes similar to the ones below.

1.5 Equipment Description
Frymaster GSMS/GBC/GC gas cookers are specifically designed to deliver high volumes of cooked or blanched food automatically. All models feature a unique infrared burner system that

delivers 80,000 BTUs (23.4 kW – 84.4, megajoules) to cook 10 pounds (4.5kg) of dry pasta per bulk basket. The cooker can also be used to reheat up to 12 10-ounce (0.28kg) packages of pre-cooked food at a time. The cookpot measures 18 x 24 x 8 inches (457 x 610 x 203 mm) and holds 2.7 gallons (48-liters) of water.
Model Comparison:
GSMS: The “Gas Spaghetti Magic System” consists of a gas cooker and rinse tank combination. The unit is equipped with a programmable controller that controls water temperature, water level, and cooking times. A swing-away water faucet is standard. An automatic basket lift system lowers and raises either bulk or individualized portions of pasta or other food products according to times programmed by the operator. Options include automatic water filling (Autofill) and starch skimming (Autoskim). The Autofill feature maintains the cookpot water level approximately 11/4-inch (32mm) below the overflow drain. The Autoskim feature sprays water on the surface of the water, forcing starch to the overflow drain. This eliminates loss of cooking time associated with removing excess starch buildup. It also keeps the water in the cookpot at the optimum level by replacing water evaporated during the cooking process. The Autoskim feature also saves energy since there is no need to refill and reheat the cookpot periodically. The cookpot is safeguarded against over filling and boilover by a large overflow drain. “SD” following the model designation indicates a stainless steel cookpot and door, and enameled cabinet. “SC” following the model designation indicates all stainless steel components.
GBC/GC: These standalone cookers are essentially the same as the GSMS, but without the built-in rinse tank. GBC models have an automatic basket lift and optional automatic water filling and starch skimming. GC models have no basket lifts and no automatic water filling and starch skimming options. The cookpot in both is safeguarded against over filling and boilover by a large overflow drain. “SD” following the model designation indicates a stainless steel cookpot and door, and an enameled cabinet. “SC” following the model designation indicates all stainless steel components.
1.6 Installation, Operating, and Service Personnel
All installation and service on Frymaster equipment must be performed by qualified, certified, licensed, and/or authorized installation or service personnel, as defined in Section 1.7.
1.7 Definitions
Qualified installation personnel are individuals, firms, corporations, and/or companies which, either in person or through a representative, are engaged in and are responsible for the installation of gas-fired appliances. Qualified personnel must be experienced in such work, be familiar with all gas precautions involved, and have complied with all requirements of applicable national and local codes.
Qualified operating personnel are those who have carefully read the information in this manual and have familiarized themselves with the equipment functions, or who have had previous experience with the operation of the equipment covered in this manual.

Qualified service personnel are those who are familiar with Frymaster equipment and who have been authorized by Frymaster Corporation to perform service on Frymaster equipment. All authorized service personnel are required to be equipped with a complete set of service and parts manuals, and to stock a minimum amount of parts for Frymaster equipment. A list of Factory Authorized Service Centers (FASC) was included with the cooker when shipped from the factory. Failure to use quali- fied service personnel will void the Frymaster Warranty on your equipment.
1.8 Shipping Damage Claim Procedure
Your Frymaster equipment was carefully inspected and packed before leaving the factory. The trans- portation company assumes full responsibility for safe delivery upon its acceptance of the equipment for transport.
What to do if your equipment arrives damaged:
FRYMASTER DOES NOT ASSUME RESPONSBILITY FOR DAMAGE OR LOSS
INCURRED IN TRANSIT.

GAS COOKERS GSMS, GBC, AND GC INSTALLATION AND OPERATION MANUAL CHAPTER 2: INSTALLATION INSTRUCTIONS
2.1 General Installation Requirements
Qualified, licensed, and/or authorized installation or service personnel, as defined in Section 1.7 of this manual, should perform all installation and service on Frymaster equipment.
Conversion of this appliance from one type of gas to another should only be performed by qualified, licensed, and/or authorized installation or service personnel as defined in Section 1.7 of this manual.
Failure to use qualified, licensed, and/or authorized installation or service personnel (as defined in Section 1.7 of this manual) to install, convert to another gas type or otherwise service this equipment will void the Frymaster warranty and may result in damage to the equipment or injury to personnel.
Where conflicts exist between instructions and information in this manual and local or national codes or regulations, installation and operation shall comply with the codes or regulations in force in the country in which the equipment is installed.
Upon arrival, inspect the cooker carefully for visible or concealed damage. (See Shipping Damage Claim Procedure in Chapter 1.)
The cooker(s) must be installed with 6 inches (150mm) clearance at both sides and back when installed adjacent to combustible construction; no construction; no clearance is required when installed adjacent to noncombustible construction. A minimum of 24 inches (600mm) clearance should be provided at the front of the cooker. To provide the airflow necessary for good combustion and burner operation, the areas surrounding the cooker front, sides, and rear must be kept clear and unobstructed.
of unacceptable concentrations of substances harmful to the health of personnel in
the room in which it is installed.
CE Standard Required airflow for the combustion air supply is 2m
3/h per kW.
One of the most important considerations of efficient cooker operation is ventilation. Cookers must be installed in an area with an adequate air supply and adequate ventilation. Make sure the cooker is

installed so that products of combustion are removed efficiently, and that the kitchen ventilation sys- tem does not produce drafts that interfere with proper burner operation.
The cooker flue opening must not be placed close to the intake of the exhaust fan, and the cooker must never have its flue extended in a “chimney” fashion. An extended flue will change the combustion characteristics of the cooker, causing longer recovery time. It also frequently causes delayed ignition.
When installed beneath a ventilation hood, adequate distance must be maintained from the flue outlet of the cooker to the lower edge of the ventilation filter bank. Filters should be installed at an angle of 45° with a drip tray placed beneath the lowest edge of the filter. For U.S. installation, NFPA standard No. 96 states, “ A minimum distance of 18 inches (450mm) should be maintained between the flue outlet and the lower edge of the filter.”
For installations in other than the United States, installers should contact the appropriate local or national agency for information on the construction and installation of ventilating hoods.
All electrically operated appliances must be grounded in accordance with all applicable national and local codes, and where applicable, CE codes. A wiring diagram is located on the inside of the cooker door. Refer to the rating plate on the inside of the cooker door for the proper voltages.
directly into properly grounded receptacle. Do not cut or remove the grounding
prong from the plug.
Do not attempt to use the equipment during a power outage.
GSMS/GBC/GC cookers are manufactured to use the type of gas specified on the rating plate. The rating plate is attached to the inside of the cooker door. Connect a cooker only to the type of gas indicated on the rating plate.
Installation shall be made with a gas connector that complies with the national and local codes or regulations in force in the country in which the appliance is being installed. Quick-disconnect devices, if used, shall likewise comply with the national and local codes or regulations in force in the country in which the appliance is being installed
When installing GSMS/GBS/GC cookers in the UNITED STATES, the installation must conform to the latest edition of the Nation Fuel Gas Code, ANSI Z223.1. In addition, installation must comply

with all local codes. In CANADA, installation must conform to Standard CAN/CGA-B149.1 or CAN/CGA-B149.2, Installation Codes for Gas Burning Appliances and Equipment. In addition, installation must comply with all local codes. In AUSTRALIA, this appliance must be installed by an authorized person in accordance with these instructions, local gas and electrical regulations, and the requirements of AA601, Installation Requirements for Gas Burning Appliances.
For countries not specifically listed above, installation shall comply with the national and local codes or regulations in force in the country in which the appliance is being installed.
The user is cautioned that any changes or modifications to Frymaster controllers not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Frymaster controllers have been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. While these devices are verified as Class A devices, they have been shown to meet the Class B limits. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of the equipment in residential areas is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. If necessary, the user should consult the dealer or an experience radio and television technician for additional suggestions. The user may find the booklet “How to Identify and Resolve Radio-TV Interference Problems” helpful. It is prepared by the Federal Communications Commission and is available form the U.S. Government Printing Office, Washington, DC 20402, Stock No. 004-000-00345-4.
2.2 Caster or Leg Installation
Depending upon the specific configuration ordered your cooker may have been shipped without installed casters or legs. If casters or legs are installed, you may skip this section and proceed to Section 2.3, Pre-Connection Preparations.
If your cooker requires the installation of casters or legs, install them in accordance with the instructions included in your accessory package.

2.3 Pre-Connection Preparations
After the cooker has been positioned under the exhaust hood, ensure the following has been accomplished:


the water line to ensure there is no trash in the line.
80 PSI (56.3 kg/cm 2). The maximum allowable incoming water temperature for all units is 180°F (82°C).

a. Plug the cooker electrical cord into a grounded electrical receptacle of appropriate voltage.
(Check the rating plate on the cooker door to determine the proper voltage).
b. Place the power switch in the ON position and verify that the display indicates – LO.
c. Place the cooker power switch in the OFF position. Verify that the display is blank.
References for CE Standard are Tables 6 and A.2 of EN 203-1:1993

2.4 Connection to the Gas Line
The GSMS/GBC/GC family of gas cookers has been approved for use with natural and propane (LP) gas. The cookers in this family have also received the
mark for the countries and gas categories indicated in the accompanying table.

CE Standard The nominal heat input (Qn) is 21kW except for AT, DE, LU and for category 3B/P under 50 mbar, which is 23kW.
G31 50 I 2E(R)B G20, G25 20, 25 I3+ G31 37

The size of the gas line used for installation is very important. If the line is too small, the gas pressure at the burner manifold will be low. This may cause slow recovery and delayed ignition. Frymaster recommends the incoming gas supply line be a minimum of 1 ½” (38mm) in diameter. Refer to the chart below for the minimum sizes of connection piping.

Gas Connection Pipe Sizes (Minimum incoming pipe size should be 1½” (38 mm))
Gas Single Unit 2-3 Units Natural ¾” (19 mm) 1” (25 mm) Propane ½” (13 mm) ¾” (19 mm)
For distances of more than 20 feet (6m) and/or more than four fittings or elbows, increase the connection by one pipe size.
Before connecting new pipe to your unit, the pipe must be thoroughly blown out to remove any foreign particles. If these foreign particles get into the burner and controls, they will cause improper and sometimes dangerous operation.
NOTE: When using thread compound, use very small amounts on male threads only. Use a pipe thread compound that is not affected by the chemical action of LP gases (i.e. propane, G31) (Loctite™ PST56765 Sealant is one such compound). DO NOT apply compound to the first two threads. This will ensure that the burner orifices and control valve do not become clogged.

and contact the local gas company or an authorized service agency for service.

water is in the cookpot before firing your unit.



Gas Pressure Natural Lacq (G20) under 20 mbar 7 mbar
2.5 Converting to Another Gas Type
DANGER Your cooker is configured at the factory for a specific type of gas. If you desire to switch from one type of gas to another, specific gas-conversion components must be installed. Switching to a different type of gas without installing the proper conversion components may result in fire or explosion! NEVER attach your cooker to a gas supply for which it is not configured. Conversion of this appliance from one type of gas to another should only be performed by qualified, licensed, and/or authorized installation or service personnel, as defined in Section 1.7 of this manual.

G20 or G25 (Natural) to G31 Gas: G31 (Propane) to G20 or G25 Gas: Orifice: 810-1970 (2 required) Orifice: 810-0916 (2 required) Ignitor Kit: 826-1715 (2 required) Ignitor Kit: 826-1714 (2 required) Conversion Rating Label 802-2144 Conversion Rating Label 802-2144

Natural Gas to LP (Propane) Gas: LP (Propane) Gas to Natural Gas: Orifice: 810-0917 (2 required) Orifice: 810-0916 (2 required) Ignitor Kit: 826-1715 (2 required) Ignitor Kit: 826-1714 (2 required) Regulator: 807-1848 (1 required) Regulator: 807-1847 (1 required) Conversion Rating Label 802-2144 Conversion Rating Label 802-2144

CE Gas Conversion Instructions 1. Between G20- and G25- type Natural Gas, adjust the gas pressure at the gas valve regulator. (Refer to the CE Standard for Burner Gas Pressure Table on Page 2-7.) Do not change the orifices. 2. Between a 2nd family (G20 or G25) and a 3rd family gas (G31 Propane): a. Change the orifices. b. Change the ignitors. c. Adjust the incoming gas pressure for the new gas. (Refer to the CE Standard for Incoming
Gas Pressure table on Page 2-5). d. Adjust the burner gas pressure at the gas valve regulator. (Refer to the CE Standard for
Burner Gas Pressure table on Page 2-8 and adjustment procedure in Chapter 4.) 3. Affix the new label included with the conversion kit next to the existing rating plate stating that the gas type has been converted. Remove any references to the previously used gas from the existing rating plate. Label PN 802-2144 4. If the destination language changes, replace the labels. (You must contact your local service agency or KES for label kit. The language of reference is indicated on the corner of the label.)
Non-CE Gas Conversion Instructions 1. Change the orifices. 2. Change the ignitors. 3. Install the regulator kit in the gas valve in accordance with the instructions furnished with the kit. 4. Adjust the incoming gas pressure for the new gas. (Refer to the Non-CE Standard for Incoming Gas Pressure table on Page 2-5.) 5. Adjust the gas pressure at the gas valve regulator. (Refer to the Non-CE Standard for Burner Gas Pressure table on Page 2-8 and adjustment procedure in Chapter 4.) 6. Affix the new label included with the conversion kit next to the existing rating plate stating that the gas type has been converted. Remove any references to the previously used gas from the existing rating plate. Label PN 802-2144 7. If the destination language changes, replace the labels. (You must contact your local service agency or KES for a label kit. The language of reference is indicated on the corner of the label.)

CHAPTER 3: OPERATING INSTRUCTIONS

6 5 4 3 2 10 7 8 9
1 Numeric Keypad 6 Skim Switch 2 Boil Mode Indicator 7 Timer Start Switch 3 Boil Mode Switch 8 Simmer Mode Switch 4 Power Switch 9 Simmer Mode Indicator 5 LED Display 10 Trouble Light
3.1 Introduction
The Spaghetti Magic Controller allows the operator to specify a cook time in minutes and seconds, then initiate a cooking cycle. This controller is available in three configurations. The standard configuration has both automatic filling (Autofill) and automatic skimming (Autoskim) features. Options include Autofill only, or neither Autofill nor Autoskim.
When in the BOIL mode, the burners are lit at all times. It is used when actually cooking pasta.
The SIMMER mode feature maintains the water temperature just below boiling, which conserves energy and water. This feature is designed for rethermalizing previously cooked packaged products and for keeping the cooker in standby.
The AUTOSKIM and SKIM features are independent of each other. The AUTOSKIM feature, on units so equipped, adds water for approximately 3 seconds once a minute. It cannot be turned off. The SKIM feature, when activated by pressing the skim button on the controller, delivers a continuous spray of water for approximately 2 minutes, then stops until the button is again pressed. In both cases, the purpose is to cause the water in the cookpot to overflow into the drain, carrying floating starch with it. (A buildup of starch reduces the efficiency of the cooker and can cause erroneous temperature and water level sensing.)

LOW WATER SENSING automatically closes the gas valve (thereby extinguishing the burner flame) if the water in the cookpot drops too low. When the water level in the cookpot is below the low-water sensor, such as when draining and cleaning the cookpot, the controller display will read LO.
NORMAL WATER LEVEL SENSING, on units configured with the Autofill feature, automatically adds water during or after a cooking cycle if the water in the cookpot drops to a level lower than approximately 1¼-inch (32 mm) below the overflow drain. With this automatic filling feature, the water level does not have to be continuously monitored. The cookpot always has the correct amount of water.
There are two versions of the SMS Controller: one that can be toggled between Fahrenheit and Celsius temperature display, and one that cannot. To determine which version you have, turn the controller off by pressing the power switch. The display will go blank. Press the Simmer (right thermometer icon) switch. If Code appears in the display, the temperature display can be changed. If not, the display cannot be changed.
3.2 Operating Instructions
Before turning the cooker on, ensure that:
3.2.1 Start-up Procedure

1. Press the power switch to the ON position. If the cooker is equipped with the Autofill option, the cookpot will automatically begin to fill with water. If not, manually fill the cookpot using the faucet until the water level is above the upper water level sensor located at the left front of the cookpot as you face the unit. (On units with Autofill, the water will automatically shut off when the water in the cookpot has reached the correct level.)


The burners should light for several seconds and then go out. A few seconds later they should light again. This cycle will repeat about 10 times, at which time the burners should remain lit until the setpoint is reached.
If the burners fail to light, press the power switch to the OFF position, wait 60 seconds, then repeat this step.

On the side of the blower housing opposite the motor is a plate with one or two locking nuts. Loosen the nut(s) enough to allow the plate to be moved, then adjust the position of the plate to open or close the air intake opening until a bright orange-red glow. Carefully hold the plate in position and tighten the lock nut(s).
3.2.2 Normal Operation
The display will automatically return to the previously set cooking time. If the same time is desired for the next batch, simply press the Start Timer switch when ready, otherwise enter the new cooking time before pressing the switch.

3.2.3 Boiling Out the Cookpot
To ensure that the cooker is free of contamination from manufacture, shipping, or handling during installation, the cookpot must be boiled out before first use.
3.3 Shutting the Cooker Down
Turn the unit off by pressing the power switch. If shutting down at the end of the day, place the gas valve in the OFF position (Non-CE units), drain and clean the cookpot (and rinse tank, if so equipped), and put the cookpot and rinse tank covers in place.

GAS COOKERS GSMS, GBC, AND GC INSTALLATION AND OPERATION MANUAL CHAPTER 4: PREVENTIVE MAINTENANCE
4.1 Daily Preventive Maintenance
It is normal for a coating of starch to form on the sensors and temperature probes during operation. If the coating is allowed to build-up, it will adversely affect the operation of the equipment. The preventive main- tenance routines below should be performed at least daily to keep your equipment functioning at peak effi- ciency. The cookpot and rinse tank – especially the water-level sensors and the temperature probe – may require more frequent cleaning, depending upon the product volume.
Inspect Equipment and Accessories for Damage
Look for loose or frayed wires and cords, leaks, foreign material in cookpot or inside cabinet, and any other indications that the equipment and accessories are not ready for safe operation.
Clean Cabinet Inside and Out
Clean inside the cabinet with a dry, clean cloth. Wipe all accessible metal surfaces and components to re- move accumulations of oil, dust, or cooking residue.
Clean the outside of the cabinet with a clean cloth dampened with dishwashing detergent, removing oil, dust, or cooking residue.
pot is filled with hot water and/or food products.
Clean Water-Level Sensors, Temperature Probe, Cookpot, and Rinse Tank

4.2 Cleaning the Gas Valve Vent Tube
This procedure should be performed at least once every 90 days.

countries. The gas valves on CE units are not equipped with vent tubes.
4.3 Cleaning and Adjusting the Combustion Air Blower

Remove these fasteners. (On black-colored FASCO blowers there are three nuts. On silver-colored KOOLTRONICS blowers there are three screws.)


On the side of the blower housing opposite the motor is a plate with one or two locking nuts. Loosen the nut(s) enough to allow the plate to be moved, then adjust the position of the plate to open or close the air intake opening until a bright orange-red glow is obtained. Carefully hold the plate in position and tighten the locking nut(s).


4.4 Adjusting the Burner Gas Pressure




Gas Pressure Natural Lacq (G20) under 20 mbar 7 mbar

4.5 Measuring Flame Current
When the burner flame is properly adjusted, it will produce a current between 2.5 µA and 3.5 µA. Flame current is measured by placing a microamp (not milliamp) meter in series with the white sensing wire on one of the ignitors. This is accomplished as follows:
4.6 Controller Simmer Mode Adjustment

determine which version of the controller you have, turn the controller off by pressing the power switch. The display will go blank. Press the Simmer Mode (right thermometer icon) switch. If Code appears in the display, the setpoint is changed via programming; if not, skip to Manual Adjustment on the next page.
Manual Adjustment

GAS COOKERS GSMS, GBC, AND GC INSTALLATION AND OPERATION MANUAL CHAPTER 5: OPERATOR TROUBLESHOOTING
5.1 Introduction
This chapter provides a reference guide to the more common problems that may occur during the operation of this equipment. The troubleshooting guides in this chapter are intended to help you correct, or at least accurately diagnose, problems with the equipment. Although the chapter covers the most common problems reported, you may very well encounter a problem not covered. In such instances, the Frymaster Technical Service Department will make every effort to help you identify and resolve the problem.
When troubleshooting a problem, always use a process of elimination starting with the simplest solution and working through the most complex. Never overlook the obvious. Anyone can forget to plug a cord into a receptacle or open the valve on the water supply line. Don’t assume that you are exempt from such occurrences. Most importantly, try to establish a clear idea of why a problem has occurred. Part of your corrective action involves taking steps to ensure that it doesn’t happen again. If a controller malfunctions because of a poor connection, check all other connections while you’re at it. If a fuse continues to blow, find out why. Keep in mind that failure of a small component may often be indicative of potential failure or incorrect functioning of a more important component or system.
Some of the troubleshooting actions recommended in this chapter involve removing suspect controllers and substituting controllers that are known to be good. Whenever this is indicated, refer to Section 5.4.
If your have doubts as to the proper action to take, do not hesitate to call the Frymaster Technical Service Department or your local Frymaster Factory Authorized Service Center for assistance.
Before calling a servicer or the Frymaster HOTLINE (1-800-551-8633):
water or to transfer hot water from one container to another.
exposed.
qualified service personnel. The equipment should be unplugged when servicing,
except when electrical tests are required.

5.2 Operator Troubleshooting Guides
Problem Probable Causes Corrective Action A. Ignition module lockout (the
A. Turn the controller OFF. Open
the control panel by removing the screws in the upper corners. If there are two ignition mod- ules, check for blown 2-amp fuses and replace as necessary. Close the control panel and press the power switch. Wait at least 4 minutes. B. Dirty water level sensors. (If the
burners failed to light within 4 seconds).
Indicator: Red trouble light on control panel is illuminated.
LIGHT (Main gas supply valve verified to be open, the gas valve in
B. Remove the probe block cover
and clean the sensors using a Scotchbrite™ or similar pad and a solution of detergent and water. C. Failed controller.
computer does not sense sufficient water in the cookpot, it will not allow the burners to fire.)
Non-CE units is verified to be ON, and
power switch is verified to be ON.)
C. Order replacement controller
from FASC or distributor.
Test: If another controller known to be working is available, substi- tute the working controller for the suspect controller. If the burners light, the controller has failed.
D. Failed ignition module or gas
C. Call FASC.
valve, or broken or loose wiring.
A. Dirty water level sensors. (If the
A. Remove the probe block cover
and clean the sensors using a Scotchbrite™ or similar pad and a solution of detergent and water. B. Failed controller.
sensors are dirty, they may cause the controller to “think” the cookpot is full.)
AUTOFILL, COOKPOT DID NOT FILL WHEN
B. Order replacement controller
from FASC or distributor.
UNIT WAS TURNED ON (Water supply to unit
Test: If another controller known to be working is available, substitute the working controller for the suspect controller. If the unit begins to fill, the controller has failed.
verified to be ON.)
C. Shorted upper water level sensor,
C. Call FASC.
failed water solenoid valve, or loose/broken wiring.

Problem Probable Causes Corrective Action A. Dirty water level sensors. (If the
A. Remove the probe block cover
and clean the sensors using a Scotchbrite™ or similar pad and a solution of detergent and water. B. Insufficient mineral content in
water level sensors are dirty, the controller may not “know” the pot is full.)
B. Add ⅛-cup of baking soda to the
water. (Pure water is not a conductor of electricity. The water level sensors actually sense impurities in the water, not the water itself.)
water in the cookpot as the unit fills. DO NOT USE SALT! Doing so will damage the cookpot. Avoid using distilled, highly filtered, or deionized water.
FULL
C. Failed upper water level sensor,
C. Call FASC.
loose or broken upper water level sensor wiring, failed water sole- noid valve.
A. Failed controller. (If the
A. Order replacement controller
NOT WORK (AUTOFILL functions
AUTOFILL functions correctly, the only cause possible is a failed controller.)
from FASC or distributor.
correctly.)
A. Failed controller.
A. Order replacement controller
from FASC or distributor. WATER WILL NOT
BOIL (Cookpot verified to be full of water with
Test: If another controller known to be working is available, substitute the working controller for the suspect controller. If the unit begins to fill, the controller has failed.
Boil Mode selected, i.e., left indicator is lit
and burners are lit.)
B. Failed temperature probe. B. Call FASC. A. Controller out of adjustment. A. Adjust controller in accordance
with procedure in Chapter 4. B. Failed controller.
B. Order replacement controller
from FASC or distributor.
Test: If another controller known to be working is available, substitute the working controller for the suspect controller. If the unit begins to fill, the controller has failed.
SIMMER MODE
B. Failed/shorted temperature probe. C. Call FASC.

Problem Probable Causes Corrective Action A. Controller out of adjustment. A. Adjust controller in accordance
with procedure in Chapter 4. B. Failed controller.
B. Order replacement controller
from FASC or distributor. WATER TEMPERATURE IS
Test: If another controller known to be working is available, substitute the working controller for the suspect controller. If the unit begins to fill, the controller has failed.
C. Open temperature probe or loose
C. Call FASC.
probe wire.
A. Lack of lubrication on basket lift
A. Lubricate lifter rods with a
rods.
lightweight lubricant.

5.3 Wiring Diagram


5.4 Replacing the Controller






Frymaster, L.L.C., 8700 Line Avenue, PO Box 51000, Shreveport, Louisiana 71135-1000
TEL 1-318-865-1711 FAX (Parts) 1-318-219-7140 (Tech Support) 1-318-219-7135
1-800-551-8633 819-5311 NOVEMBER 2001
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| BURNERS DO NOT LIGHT (Main gas supply valve verified to be open, the gas valve in Non-CE units is verified to be ON, and power switch is verified to be ON.) | A. Ignition module lockout (the burners failed to light within 4 seconds). Indicator: Red trouble light on control panel is illuminated. | A. Turn the controller OFF. Open the control panel by removing the screws in the upper corners. If there are two ignition mod- ules, check for blown 2-amp fuses and replace as necessary. Close the control panel and press the power switch. Wait at least 4 minutes. | p.28 |
| BURNERS DO NOT LIGHT (Main gas supply valve verified to be open, the gas valve in Non-CE units is verified to be ON, and power switch is verified to be ON.) | B. Dirty water level sensors. (If the computer does not sense sufficient water in the cookpot, it will not allow the burners to fire.) | B. Remove the probe block cover and clean the sensors using a Scotchbrite™ or similar pad and a solution of detergent and water. | p.28 |
| BURNERS DO NOT LIGHT (Main gas supply valve verified to be open, the gas valve in Non-CE units is verified to be ON, and power switch is verified to be ON.) | C. Failed controller. Test: If another controller known to be working is available, substi- tute the working controller for the suspect controller. If the burners light, the controller has failed. | C. Order replacement controller from FASC or distributor. | p.28 |
| BURNERS DO NOT LIGHT (Main gas supply valve verified to be open, the gas valve in Non-CE units is verified to be ON, and power switch is verified to be ON.) | D. Failed ignition module or gas valve, or broken or loose wiring. | C. Call FASC. | p.28 |
| ON UNIT WITH AUTOFILL, COOKPOT DID NOT FILL WHEN UNIT WAS TURNED ON (Water supply to unit verified to be ON.) | A. Dirty water level sensors. (If the sensors are dirty, they may cause the controller to “think” the cookpot is full.) | A. Remove the probe block cover and clean the sensors using a Scotchbrite™ or similar pad and a solution of detergent and water. | p.28 |
| ON UNIT WITH AUTOFILL, COOKPOT DID NOT FILL WHEN UNIT WAS TURNED ON (Water supply to unit verified to be ON.) | B. Failed controller. Test: If another controller known to be working is available, substitute the working controller for the suspect controller. If the unit begins to fill, the controller has failed. | B. Order replacement controller from FASC or distributor. | p.28 |
| ON UNIT WITH AUTOFILL, COOKPOT DID NOT FILL WHEN UNIT WAS TURNED ON (Water supply to unit verified to be ON.) | C. Shorted upper water level sensor, failed water solenoid valve, or loose/broken wiring. | C. Call FASC. | p.28 |
| ON UNIT WITH AUTOFILL, WATER DID NOT SHUT OFF WHEN COOKPOT WAS FULL | A. Dirty water level sensors. (If the water level sensors are dirty, the controller may not “know” the pot is full.) | A. Remove the probe block cover and clean the sensors using a Scotchbrite™ or similar pad and a solution of detergent and water. | p.29 |
| ON UNIT WITH AUTOFILL, WATER DID NOT SHUT OFF WHEN COOKPOT WAS FULL | B. Insufficient mineral content in water. (Pure water is not a conductor of electricity. The water level sensors actually sense impurities in the water, not the water itself.) | B. Add ⅛-cup of baking soda to the water in the cookpot as the unit fills. DO NOT USE SALT! Doing so will damage the cookpot. Avoid using distilled, highly filtered, or deionized water. | p.29 |
| ON UNIT WITH AUTOFILL, WATER DID NOT SHUT OFF WHEN COOKPOT WAS FULL | C. Failed upper water level sensor, loose or broken upper water level sensor wiring, failed water sole- noid valve. | C. Call FASC. | p.29 |
| AUTOSKIM DOES NOT WORK (AUTOFILL functions correctly.) | A. Failed controller. (If the AUTOFILL functions correctly, the only cause possible is a failed controller.) | A. Order replacement controller from FASC or distributor. | p.29 |
| WATER WILL NOT BOIL (Cookpot verified to be full of water with Boil Mode selected, i.e., left indicator is lit and burners are lit.) | A. Failed controller. Test: If another controller known to be working is available, substitute the working controller for the suspect controller. If the unit begins to fill, the controller has failed. | A. Order replacement controller from FASC or distributor. | p.29 |
| WATER WILL NOT BOIL (Cookpot verified to be full of water with Boil Mode selected, i.e., left indicator is lit and burners are lit.) | B. Failed temperature probe. | B. Call FASC. | p.29 |
| WATER BOILS IN SIMMER MODE | A. Controller out of adjustment. | A. Adjust controller in accordance with procedure in Chapter 4. | p.29 |
| WATER BOILS IN SIMMER MODE | B. Failed controller. Test: If another controller known to be working is available, substitute the working controller for the suspect controller. If the unit begins to fill, the controller has failed. | B. Order replacement controller from FASC or distributor. | p.29 |
| WATER BOILS IN SIMMER MODE | B. Failed/shorted temperature probe. | C. Call FASC. | p.29 |
| WATER TEMPERATURE IS TOO LOW IN SIMMER MODE | A. Controller out of adjustment. | A. Adjust controller in accordance with procedure in Chapter 4. | p.30 |
| WATER TEMPERATURE IS TOO LOW IN SIMMER MODE | B. Failed controller. Test: If another controller known to be working is available, substitute the working controller for the suspect controller. If the unit begins to fill, the controller has failed. | B. Order replacement controller from FASC or distributor. | p.30 |
| WATER TEMPERATURE IS TOO LOW IN SIMMER MODE | C. Open temperature probe or loose probe wire. | C. Call FASC. | p.30 |
| BASKET LIFT MOVEMENT IS JERKY OR NOISY | A. Lack of lubrication on basket lift rods. | A. Lubricate lifter rods with a lightweight lubricant. | p.30 |
Owners and our team usually reply within a day — and your question helps the next person too.