NON-CE & Frymaster, a member of the Commercial Food Equipment Service Association, recommends using CFESA Certified Tec hnicians. PRINTED IN THE UNITED STATES 24-Hour Service Hotline 1-800-551-8633 www.frymaster.com Email: service@frymaster.com *8195613* APRIL 2005 Series FMCF, FMCFE, FMCFEC, MJCF, MJCFE, MJCFEC, KJ3FC, JCFX, J3F & J65X.
ii NOTICE This appliance is intended for professional use only and is to be operated by qualified personnel only. A Frymaster/DEAN Factory Authorized Service Center (FASC) or other qualified professional should perform installation, maintenance, and repairs.
iii DANGER Adequate means must be provided to limit the movement of this appliance without depending upon the gas line connection. Single fryers equipped with legs must be stabilized by installing anchor straps. All fryers equipped with casters must be stabilized by installing restraining chains.
iv CF Series Gas Fryers TABLE OF CONTENTS P A G E # CHAPTER 1: General Information 1.1 Applicability and Validity ................................................................................................. ............. 1-1 1.2 Parts Ordering and Service Information .
CF SERIES GAS FRYERS CHAPTER 1: INTRODUCTION 1-1 1.1 Applicability and Validity The CF Series Gas Fryer model family has been approved by the European Union for sale and installation in the following EU countries: AT, BE, DE, DK, ES, FI, FR, GB, IE, IT , LU, NL, NO, PT and SE.
CF SERIES GAS FRYERS CHAPTER 1: INTRODUCTION 1-2 1.3 Safety Information Before attempting to operate your unit, read the instructions in this manual thoroughly. Your fryer is equipped with tw o automatic safety features: • High temperature detection shuts off gas to the burner assembly should the con trolling thermostat fail.
CF SERIES GAS FRYERS CHAPTER 1: INTRODUCTION 1-3 1.5 Equipment Description CF Series gas fryers are specifically designed for high volume frying, especially fish, chicken and other breaded products. Models in this seri es include FMCF, FMCFE, FMCFEC, MJCF, MJCFE, MJCFEC, KJ3FC and J65X variants.
CF SERIES GAS FRYERS CHAPTER 1: INTRODUCTION 1-4 1.6 Installation, Operating, and Service Personnel Operating information for Frymaster equipment has been prepared for use by qualified and/or authorized personnel only, as defined in Section 1.
CF SERIES GAS FRYERS CHAPTER 1: INTRODUCTION 1-5 1.8 Shipping Damage Claim Procedure Your Frymaster equipment was car efully inspecte d and packed before leaving the factory. T he transportation company assum es full responsib ility for safe delivery upon acceptance of the equipment for transport.
CF SERIES GAS FRYERS CHAPTER 2: INSTALLATION INSTRUCTIONS 2-1 2.1 General Installation Requirements Qualified, licensed, and/or authorized installati on or service perso nnel, as defined in Section 1.7 of this manual, should perf orm all installation and servi ce on Frymaster equipment.
CF SERIES GAS FRYERS CHAPTER 2: INSTALLATION INSTRUCTIONS 2-2 CLEARANCE AND VENTILATION DANGER No structural material on the fryer shoul d be altered or removed to accommodate placement of the fryer under a hood. Questi ons? Call the Frymaster/Dean Service Hotline at 1-800-551-8633.
CF SERIES GAS FRYERS CHAPTER 2: INSTALLATION INSTRUCTIONS 2-3 NATIONAL CODE REQUIREMENTS The type of gas for which the fryer is equipped is stamped on the data plate a ttached to the inside of the fryer door.
CF SERIES GAS FRYERS CHAPTER 2: INSTALLATION INSTRUCTIONS 2-4 If necessary, the user should consult the d ealer or an experienced radio and television technician for additional suggestions. The user may find the booklet "H ow to Identify and Resolve Ra dio-T V Interference Problems" helpful.
CF SERIES GAS FRYERS CHAPTER 2: INSTALLATION INSTRUCTIONS 2-5 3. Level fryers equipped with legs by screwing out the legs approximately 1 inch, and then adjust them so that the fryer is level a nd at th e proper height in the exhaust hood.
CF SERIES GAS FRYERS CHAPTER 2: INSTALLATION INSTRUCTIONS 2-6 2.4 Connection to Gas Line DANGER Before connecting new pipe to this a ppliance, the pipe must be blown out thoroughly to remove all foreign material. Foreign material in the burner and gas controls will cause improper and dangerous operation.
CF SERIES GAS FRYERS CHAPTER 2: INSTALLATION INSTRUCTIONS 2-7 Ga s Conne ct ion P i pe S i z e s [ M ini m um i ncom ing pi pe s iz e s houl d be 1- 1/2" ( 38 m m ) ] N atur al 3/4" ( 19 m m.
CF SERIES GAS FRYERS CHAPTER 2: INSTALLATION INSTRUCTIONS 2-8 3. Close the fryer drain valve and fill the frypot with water and boil-out so lution to the bottom OIL- LEVEL line at the rear of the frypot.
CF SERIES GAS FRYERS CHAPTER 2: INSTALLATION INSTRUCTIONS 2-9 DANGER This appliance was configured at the factory for a specific type of gas. Converting from one type of gas to another requires the installation of specific gas-conversion components.
CF SERIES GAS FRYERS CHAPTER 2: INSTALLATION INSTRUCTIONS 2-10 The following gas-conversion components and kits are available from your FASC: CE Only: Propane (G31) to Natural (G20/G2 5) Regulator onl.
CF SERIES G A S FRYERS CHAPTER 3: OPER ATING INSTRU CTIONS 3-1 3.1 Start-Up Procedure DA NGER Never operate t his appliance with an empty frypot. The fry pot must be filled with water (non-KFC co-branded locations) or c ooking oil/shortening b e fore lighting the burners.
CF SERIES GA S FRYERS CHAPTER 3: OPERA TING INSTRUCTIONS 3-2 A CCESSING THE PILOT The pilot is mounted on the left side of the burner manifold and is accessed throu gh an opening in the front frypot insulation. Swing the round cover open and insert a long match or taper through the hole (see photo) when li ghting the pilot.
CF SERIES GA S FRYERS CHAPTER 3: OPERA TING INSTRUCTIONS 3-3 LIGHTING THE PILOT ON FRYERS WITH CE HONEYWELL GA S V ALVES 1. Ensure power to the unit is OFF, and then press the OFF (red) button.
CF SERIES GA S FRYERS CHAPTER 3: OPERA TING INSTRUCTIONS 3-4 For units equipped wit h other t han Therm ostat Contr ols (non-KFC c o-brande d locations) Place the computer/controller ON/OF F switch in the ON position and set the controller to – or program the computer for – the desired c ooking temperature, r eferred to as the setpoint .
CF SERIES GA S FRYERS CHAPTER 3: OPERA TING INSTRUCTIONS 3-5 5. For units equipped with a Computer Magic III.5 Computer : • Press the Power switch followed by the Program Mode switch . will appear in the left displa y. • Enter the code number (1653).
CF SERIES GA S FRYERS CHAPTER 3: OPERA TING INSTRUCTIONS 3-6 3.3 Shutting the Fr yer Down For short-term shut down during the workda y , place the fryer power switch in the O FF position and put the frypot covers in place (i f the fryer is so equipped).
CF SERIES GAS FRYERS CHAPTER 4: FILTRATION INSTRUCTIONS 4-1 4.1 Draining and Manual Filtering WARNING The on-site supervisor is responsible for ensuring that operators are made a ware of the inherent hazards of operating a hot oil filtering system, particularly the aspects of oil filtration, draining and cleaning procedures.
CF SERIES GAS FRYERS CHAPTER 4: FILTRATION INSTRUCTIONS 4-2 If you are using a Frymaster filter cone holder, be sure that the cone holder rests securely on the metal container.
CF SERIES GAS FRYERS CHAPTER 4: FILTRATION INSTRUCTIONS 4-3 4.2 Filter Magic II Filtration System Operation The Filter Magic II filtration system allows the oil in one frypot to be filtered while the other frypots in a battery remain in operation.
CF SERIES GAS FRYERS CHAPTER 4: FILTRATION INSTRUCTIONS 4-4 4.2 Filter Magic II Filtration System Operation (cont.) 3. Wipe any debris and excess oil from the bottom of the pan. The paper must lay flat and seal around the edges for proper filtration. Replace th e filter paper support screen removed in Step 2.
CF SERIES GAS FRYERS CHAPTER 4: FILTRATION INSTRUCTIONS 4-5 4.2 Filter Magic II Filtration System Operation (cont.) 6. Sprinkle filter powder over the filter paper. For powder quantity, see the filter powder manufacturer’s instructio ns. 7. Replace the crumb tray in the filter pan.
CF SERIES GAS FRYERS CHAPTER 4: FILTRATION INSTRUCTIONS 4-6 OPERATION OF THE FILTER UNIT CAUTION NEVER operate the filter unit unless the o il is at operating temperature [~350°F (~177°C)]. 1. To filter the oil, bring oil to operating temperature and turn the fryer power OFF.
CF SERIES GAS FRYERS CHAPTER 4: FILTRATION INSTRUCTIONS 4-7 DANGER DO NOT operate the filt er without the Power Shower in place. Hot oil will spray out of the fryer and may cause injury. 3. Snap the Power Shower into the frypot. Ensure the cleanout plugs are in place before activating filter pump.
CF SERIES GAS FRYERS CHAPTER 4: FILTRATION INSTRUCTIONS 4-8 5. Remove the Power Shower and a llow it to drain. Ensure the drain valve is fully closed (arrow). Turn the fryer ON and allo w the oil to reach setpoint. NOTE: Ensure the fryer drain valve is fully closed before turning the fry er on.
CF SERIES GAS FRYERS CHAPTER 5: PREVENTATIVE MAINTENANCE 5-1 5.1 Fryer Preventive Maintenance Checks and Services DAILY CHECKS AND SERVICES Inspect Fryer and Accessories for Damage Look for loose or f.
CF SERIES GAS FRYERS CHAPTER 5: PREVENTATIVE MAINTENANCE 5-2 WEEKLY CHECKS AND SERVICES Check Recovery Time Recovery Time is the amount of tim e it takes the fryer to increase the frypot temperature from 250 ° F (121 ° C) to 300 ° F (149 ° C). It is a measure of the fryer’s efficiency, and it should be no more than 3 minutes and 30 seconds.
CF SERIES GAS FRYERS CHAPTER 5: PREVENTATIVE MAINTENANCE 5-3 If your fryer is not equipped with the built-in Filter Ma gic II Filtration system, the oil m ust be drained into another suitab le container. For safe, convenient dr aining and disposal of used oil, Frymaster recommends the use of our shortening disposal unit (SDU).
CF SERIES GAS FRYERS CHAPTER 5: PREVENTATIVE MAINTENANCE 5-4 Check Thermostat Controller Thermostat Calibration (This check applies only to units equi pped with Thermostat Controllers) 1.
CF SERIES GAS FRYERS CHAPTER 5: PREVENTATIVE MAINTENANCE 5-5 SEMI-ANNUAL CHECKS AND SERVICES Check Burner Manifold Pressure DANGER This task should be performed by qualified service personnel only.
CF SERIES GAS FRYERS CHAPTER 5: PREVENTATIVE MAINTENANCE 5-6 5.3 Annual/Periodic System Inspection This appliance should be inspected and adjusted periodically by qualified service personnel as part of a regular kitchen maintenance program.
CF SERIES GAS FRYERS CHAPTER 5: PREVENTATIVE MAINTENANCE 5-7 Built-In Filtration System • Inspect all oil-return and drai n lines for leaks and verify th at all connections are tight.
CF SERIES GAS FRYERS CHAPTER 6: OPERATOR TROUBLE SHOOTING 6-1 6.1 Introduction This chapter provides an easy reference guide to the more common problem s that may occur during the operation of your equipment. The troubleshooting guides in this chapter are intended to help you correct, or at least accurately di agnose, problems with your equipment.
CF SERIES GAS FRYERS CHAPTER 6: OPERATOR TROUBLESHOOTING 6-2 6.2 Troubleshooting Fryers with Solid State (Analog), Digital, or CM I II.5 Controllers PROBLEM PROBABLE CAUSES CORRECTIVE ACTION A. Pilot not lit. A. Light pilot per instructions in Chapter 3 of this manual.
CF SERIES GAS FRYERS CHAPTER 6: OPERATOR TROUBLESHOOTING 6-3 6.2 Troubleshooting Fryers with Solid State (Analog), Digital, or CM I II.5 Controllers (cont.) PROBLEM PROBABLE CAUSES CORRECTIVE ACTION CM III.5 will not go into programming mode. (cont.) B.
CF SERIES GAS FRYERS CHAPTER 6: OPERATOR TROUBLESHOOTING 6-4 6.3 Troubleshooting Fryers with Thermostat Controls PROBLEM Probable Causes Corrective Action A. Pilot is not lit. A. Light pilot per instructions in Chapter 3 of this manual. B. Drain valve not fully closed.
CF SERIES GAS FRYERS CHAPTER 6: OPERATOR TROUBLESHOOTING 6-5 6.4 Troubleshooting the Built-In Filtration System (cont.) PROBLEM PROBABLE CAUSES CORRECTIVE ACTION B. Failed filter handle microswitch. Test : If this is a multi-pot f ryer, attempt to operate the p ump using a different handle.
CF SERIES GAS FRYERS CHAPTER 6: OPERATOR TROUBLESHOOTING 6-6 6.4 Troubleshooting the Built-In Filtration System (cont.) PROBLEM PROBABLE CAUSES CORRECTIVE ACTION B.
CF SERIES GAS FRYERS CHAPTER 6: OPERATOR TROUBLESHOOTING 6-7 6.5 Troubleshooting Abnormal Burner Operation PROBLEM PROBABLE CAUSES CORRECTIVE ACTION Flame is visible above flue opening and burner is excessively noisy. A. Burner gas pressure is too high.
CF SERIES GAS FRYERS CHAPTER 6: OPERATOR TROUBLESHOOTING 6-8 6.6 Replacing the Controller or Controller Wiring Harness 1. Disconnect the fryer from the electrical supply. 2. The controller bezel is held in place by tabs at the top and bottom. Slide the b ezel up to disengage the lower tabs.
THIS PAGE INTENTIONALLY LEFT BLANK.
Frymaster, L.L. C., 8700 Line Avenue, PO Bo x 51000, Sh reveport, Louisi ana 71135-100 0 Shipping Address: 8700 Line Avenue, Shreveport, Louisiana 711 06 TEL 1-318-865-171 1 FAX (Parts) 1-318-2 19-71 40 FAX (Tech Support) 1-31 8-219-7135 Price: $12.
An important point after buying a device Frymaster CF Series (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Frymaster CF Series yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Frymaster CF Series - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Frymaster CF Series you will learn all the available features of the product, as well as information on its operation. The information that you get Frymaster CF Series will certainly help you make a decision on the purchase.
If you already are a holder of Frymaster CF Series, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Frymaster CF Series.
However, one of the most important roles played by the user manual is to help in solving problems with Frymaster CF Series. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Frymaster CF Series along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center