Frymaster, a member of the Commercial Food Equipment Service Association, recommends using CFESA Certified Technicians.





a. The Flatbottom 24G (CE)/H250 Fryer System is equipped with the Super Cascade Filter
Model 99.
b. For consistent product quality, convenience and long-term savings, use a high-quality liquid
frying compound.
c. The frying compound should be filtered at least daily or even more frequently if cooking is
heavy. This ensures the longest life possible for the frying compound, gives better taste to the food being prepared, and minimizes flavors being transferred from batch to batch.
d. If using solid shortening, always make sure the return lines are clear before turning off the
filter motor and hang any flexible lines up to drain. Solid shortening will solidify as it cools and clog the lines.
The on-site supervisor is responsible for ensuring that operators are made aware of the inherent dangers of operating a hot oil filter system, particularly aspects of oil filtration, draining, and cleaning of the filter.
a. Assemble tools to be used for filtering. These are supplied with the filter starter kit:
other filter powder may clog filter paper causing longer refill times and could cause premature motor failure.
b. The following tools are not required, but are recommended to make the filtering task easier.
c. Always wear oil-resistant, insulated gloves and/or protective gear when working with hot
oil.
d. Put on protective gear.
e. Pull the filter pan out from the Flatbottom 24G fryer/ filter cabinet. Remove cover.

f. Unlatch and remove the hold down ring.

Remove and discard old filter paper sheet from the filter pan.
g. Clean out the filter pan.
h. Place one sheet of filter paper in the bottom of
the filter pan. Reinstall and latch the hold down ring into position.
i. Sprinkle 8 ounces (1 cup)/ 227 grams evenly
over the paper. Return cover to the filter pan.
Hold down ring latched into position.
j. Return filter pan to fryer cabinet, making sure
the two drain pipe extensions are directly over openings in filter pan cover.
k. Ensure the oil pickup tube fits snugly in the

filter pan connector.
Filter one frypot at a time. The filter pan is designed to safely hold the oil from one fryer only.
Filter Pan Lid Drain Holes


SCF99 ready for operation.



Flatbottom Drain Valve in Closed Position
panel of the filter cabinet. If the circuit breaker trips, the filter pump will stop, manually reset breaker, and continue.
Replace filter paper when it becomes dark or scuffed in appearance or if refill time becomes extended.

Air bubbles from the Oil Return Line
Oil return handle · Flatbottom 24G


H250 Drain & Oil Return Handles
panel of the filter cabinet. If the circuit breaker trips, the filter pump will stop, manually reset breaker and continue.
Replace filter paper when it becomes dark or scuffed in appearance or if refill times become extended.
Air bubbles from the Oil Return Line
Oil Return Handle · Drain Valve · Handle

The problems and possible solutions covered are those most commonly encountered.
To troubleshoot, perform the test set-up at the beginning of each condition. Start at the top of the diagram. Arrows direct the troubleshooter through the sequence. Follow each step in sequence as shown in the troubleshooting diagrams.
INSPECTION, TESTING, AND REPAIR OF GAS OR ELECTRICAL EQUIPMENT SHOULD BE PERFORMED BY QUALIFIED PERSONNEL.
USE EXTREME CARE DURING ELECTRICAL CIRCUIT TESTS. LIVE CIRCUIT WILL BE EXPOSED.
Filter pump fails to pump
oil.
Reset filter circuit breaker and wall circuit
breaker (if necessary).
Turn pump motor ON by turning the
oil return handle.
No There may be blockages in the
Is the pump motor running?
oil lines.
Go to page 7 and follow procedures
operations.
Servicer.
for Rate of Oil Return Slowing.

Rate of oil return
to the fryer is
slowing.
Is this the first fryer to be
Check the filter sump. Sediment collects around the suction pipe in the filter pan bottom.
Remove the filter pan cover.
filtered in this filtering session?
Unlatch hold down ring and remove filter paper and filter paper support grid.
Check the filter paper in
the filter pan.
Is the filter paper properly secured by the
Clean support grid and set aside temporarily.
Paper may not be secured by the hold down ring. Air is being allowed into the filter system.
Wipe sediments out of the filter pan bottom.
Paper may be plugged due to improper use of filter powder.
Inspect drain port on the oil pickup tube in the filter pan bottom and remove any sediment or visible blockages.
Change the filter paper. Take a new sheet and place it in the bottom of the filter pan.
Reassemble the filter pan assembly. Turn pump motor ON by turning the oil return handle.
Secure the filter paper by snapping the hold down ring into place.
Sprinkle 8 oz/.27kg of filter powder evenly across the filter paper surface.
Blockage may be between the filter pan bottom and the oil return valve.
No Has the oil return rate improved?
Go to the flowchart titled "Blockage between Filter Pan and the Oil Return Valve.
Conduct normal filter operations.
hold down ring?

Blockage has been determined to be between the filter pan bottom and the oil return valve.
Disconnect oil line running from the filter pan to the pump at the pump end.
Activate pump by turning
oil return valve handle.
Check filter circuit breaker. Push the filter circuit breaker reset button
located in the right-hand fryer.
Activate pump by turning
oil return valve handle.
Allow the pump to run 20 seconds to verify that pump is not running backwards.
Filter motor's internal circuit breaker has tripped.
Put finger over the inlet connection to the filter pump.
Contact your local Factory Authorized Service Center.
No Pump motor is clogged or faulty.
Contact your local Factory Authorized
Pump is clear of any blockages. Go to page 9
Service Center.
and continue.

Enter from page 8 here.
Plug is in the bottom of the filter pan or in the line from the
NEVER USE A PROPANE TORCH TO MELT SOLIDIFIED SHORTHENING IN ANY PART OF THE SYSTEM. YOU WOULD BE USING AN OPEN FLAME NEAR COMBUSTIBLES. THE FIRE HAZARD IS EXTREME!
filter to the pump.
Disconnect the tubing from
the filter pan to the motor. Make sure the pipe is cool.
Can you blow air
No The line is clogged.
The line is clear. Reconnect hose to the
Run a cable through the
line to clear clogs. Continue until you can
pump inlet.
blow air through it.
Turn pump ON.
No There may be a plug in
the oil return line
system.
Disconnect the oil return line running from the pump to the oil
Conduct normal filter operations.
return valve. Clean the pipe to
remove residual shortening.
Disconnect the oil return line running from the oil return valve
to the frypot. Clean the pipe to
remove residual shortening.
return lines.
Turn pump ON.
Servicer.
Conduct normal filter operations.



Frymaster, L.L.C., 8700 Line Avenue, PO Box 51000, Shreveport, Louisiana 71135-1000