ELECTRO-FRYING MACHINE

This chapter on the machine must be placed in the section of the frying machine

VON
P.O. BOX 51000 SHREVEPORT, LOUISIANA 71135-1000
TEL: 1-318-865-1711 GEBÜHRENFREI: 1-800-551-8633
1-800-24 FRYER FAX: 1-318-219-7135
LIST OF CONTENTS
WARRANTY STATEMENT PAGE I INTRODUCTION PAGE 1-1 INSTALLATION INSTRUCTION PAGE 2-1 OPERATIONAL INSTRUCTION SITE 3-1 OPERATION OF THE BUILT-IN FILTERING SYSTEM PAGE 4-1 PREVENTIVE MAINTENANCE PAGE 5-1 OPERATOR TROUBLESHOOTING PAGE 6-1
Frymaster L.L.C., 8700 Line Avenue 71106 Address: P.O. Box 51000, Shreveport, Louisiana 71135-1000
TEL 318-865-1711 FAX 318-219-7135 PRINTED IN THE USA SERVICE HOTLINE 1-318-865-1711 SEP 2003 *8196013*

NOTE: IF DURING THE WARRANTY TERM, CUSTOMER USES A PART FOR THIS ENODIS EQUIPMENT THAT IS NOT AN UNMODIFIED, NEW OR RECYCLED PART PURCHASED DIRECTLY FROM FRYMASTER/DEAN OR ANY AUTHORIZED FRYMASTER/DEAN SERVICE POINT AND/OR THE USED PART HAS BEEN MODIFIED TO ITS ORIGINAL CONDITION, SUCH WARRANTY WILL BE VOID. FURTHERMORE, FRYMASTER/DEAN AND ITS SUBSIDIARIES ARE NOT LIABLE FOR ANY CLAIMS, DAMAGE OR COSTS INCURRED BY THE CUSTOMER AS A RESULT OF INSTALLATION OF A MODIFIED PART AND / OR PART FROM AN UNAUTHORIZED SERVICE CENTER.
NOTE This device is intended for commercial use only and must be operated by qualified personnel. Installation, maintenance and repairs must be carried out by a service agency (FASC) authorized by the Frymaster/Dean plant or another qualified technician. Installation, maintenance or repairs by non-qualified personnel may nullify the manufacturer’s warranty. Chapter 1 of this manual contains the definitions for qualified personnel.
NOTE This device must be installed in accordance with the relevant country and local regulations of each installation country. For details, see the REQUIREMENT for AUTHORITY RULES in Chapter 2 of this manual.
NOTES FOR CUSTOMERS IN THE US This device must be installed in such a way that it complies with the basic installation rules of Building Officials and Code Administrators International, Inc. (BOCA) and the Food Service Sanitation Manual of the Food and Drug Administration (FDA).
NOTE Drawings and photographs in this manual illustrate operational, cleaning and technical procedures and do not necessarily correspond to the operating practices of local kitchen management.
USA This device complies with Part 15 of the FCC regulations. Operation shall be subject to the following two conditions: 1 This equipment must not cause any interference and 2 this equipment must be capable of receiving noise signals which could cause undesirable operation. This device is classified as Class A, but it meets the limits of class B devices.
This digital device does not exceed the limits of Class A or B for radio emissions set by standard ICES-003 from the Canadian Department of Communications.

1.1 General Before attempting to operate the device, read through well the instructions in this manual. This guide covers all configurations of the PH14 models for McDonald’s. The frying machines in this model family have many parts in common, which are called “PH14” fryers when treated together as a group. These frying machines are similar in appearance to the electric BIH14 McDonald’s fryers, but BIPH14 Frying Machines have a built-in filter system with considerable differences. Other functional features, including deep cold zones and open frying tubs with hinged heating elements are virtually unchanged. Operating options include analogue control (solid state) or computer M2000. This series of machines is offered with undivided or divided frying trough; they can be purchased as individual machines or batteries for up to six machines. 1.2 Safety information Before attempting to operate the device, read through well the instructions in this manual. This manual contains instructions in double-edged boxes – see below.
WARNINGS contain information about actions or conditions that Damage to equipment lead and may result in malfunctions of the equipment.
DANGER WARNINGS contain information about actions or conditions that to Result in personal injury and may result in damages and/or malfunction of the equipment. The frying machines in this series are equipped with the following automatic safety functions: 1. Two high temperature detection functions turn off the power supply to heating elements when temperature control fails. 2. A safety switch in the drain valve prevents that the heating elements can heat when the drainage valve is also only partially open.

1.3 Computer information for devices with computer M2000
This device has been tested and therefore meets the limits for a Class A digital device according to Part 15 of FCC regulations. This device is classified as Class A, but it meets the limits of class B devices. If the device is operated in a commercial environment, these limits are intended to provide acceptable protection against interference. This device generates and uses high-frequency energy, which can also emit it; if not installed and used as specified in the instructions manual, radio/TV reception may be disturbed. The operation of the device in a residential area is likely to cause disturbances; in this case, the user is obliged to correct these disturbing events at his own expense. The user is warned that any changes not expressly approved by the party responsible for conformity may nullify the user’s authorization to operate this device. If necessary, the user should consult with the dealer or an experienced radio and TV technician. The user can find the following booklet prepared by the US Federal Communications Commission helpful: “How to Identify and Resolve Radio-TV Interference Problems”. This brochure is available at the following address: U.S. Government Printing Office, Washington, DC 20402, U.S.A., Stock No 004-000-00345-4. 1.4 Specific information for the European Community (CE) The European Community (CE) has established certain standards for this type of equipment. If there are differences between a CE standard and an outside of the CE, the relevant information or instructions will be displayed by shaded text fields as shown below.
Non-CE specific information.
1.5 Claims for damage in the event of transport damage Measures to be taken if the equipment is damaged: It should be noted that the device has been carefully inspected and packaged by trained personnel before delivery from the factory. The carrier assumes all responsibility for secure delivery as soon as he has taken over the device for transport. 1. Immediately submit a claim for damages – regardless of the extent of the damage. 2. Visible damage, missing parts – Make sure that this is noted on the freight voucher or express transport vouch and signed by the person to be delivered. 3. Non-visible damage, missing parts – If the damage can only be detected after unpacking the device, notify the carrier immediately and submit a claim for non-visual damage. This should be done within 15 days of the delivery date. Make sure that the packaging container is picked up for inspection.

1.6 Service information For non-routine maintenance or repairs, or for service information, contact the local Frymaster Authorized Service Center (FASC). Service information can also be obtained by telephone from Frymaster’s maintenance department at 1-800-24FRYER (USA/Canada). In order to help you better, we need the following information:
Model number Serial Number Voltage Type of problem
KEEP IT IN A SAFE PLACE.



2.1 A correct installation is a prerequisite for the safe, efficient and error-free operation of this device. Any unauthorized modifications to this device will nullify the Frymaster warranty.
NOTE This apparatus is wired directly to the power supply; a contact at least 3 mm apart for all poles in fixed wiring shall be provided to interrupt the power.
NOTE This device shall be positioned so that the plug is accessible unless another power supply interruption (disconnect switch) is provided.
NOTE When this unit is hardwired with the power supply, copper wire shall be used which can operate at least 75 °C (167 °F).
If the power cord is damaged, it must be provided by an authorized Frymaster/Dean service agency or be replaced by a qualified person to avoid hazards.

All installation and maintenance work on Frymaster equipment must be carried out by qualified, certified and/or authorized installation and service personnel. Customer service is available from the local FASC. In the event of a prolonged power failure, the frying machine is automatically switched off. In this case, set the power switch to OFF. Do not try to turn the frying machine back on during a power failure. The installation area of the frying machine must always be kept free from combustible material; however, it may be placed on combustable floors. On both sides and at the back, a clearance of 15 cm (6 in) must be left for combustible building materials. At least a clearance of 61 cm (24 in) must be left on the front side of the frying machine to allow proper operation and maintenance.
will become.
NOTE When this unit is hardwired with the power supply, copper wire shall be used which can operate at least 75 °C (167 °F).


To level the frying machines, adjust the stand legs so that the feasting machine(s) in the friting station have the correct height.



3.1 Preparation and disconnection procedure for equipment
1. Fill the frying trough with vegetable oil to the lower line of the oil filling at the rear side of the friting tub. This leaves room for the expansion of oil during heating. Do not fill cold oil beyond the bottom line; hot oil will overflow as it expands when heated. 2. Ensure that the power cord(s) are connected to suitable socket(s). Ensure that the plug is pressed completely into the socket. 3. Ensure that the oil is up to uppermost OIL FLUITING STANDARD is filled when the oil the frying temperature has reached. It may be necessary to refill oil in order to bring the level of filling up to the correct height, after it has reached the frying temperature. Switch off 1. Switch off the frying machine. 2. Filter the vegetable oil (see chapters 4 and 5) and clean the frying machine. 3. Place the lids on top of the frying tray. 3.2 Operation When the frying machine is put into operation for the first time after installation, it must be Method on page 5-2 for boiling the frying tub. This frying machine can be equipped with a computer M2000 (pictured below) or an analog control. For devices with the computer M2000, in a separate manual M2000 Computer Operating Instructions (operating instructions for computer M2000) which is supplied with the frying machine.

COMPUTER M2000 Chapter 4 of this manual provides operating instructions for the built-in filtering system.

Use of analogue control (solid state) The analog control shown below serves to set and maintain the oil temperature, which is indicated on the thermostat button. The frying machine has two built-in upper limit protection functions. When the temperature in the frying tub reaches about 210 °C (410 °F), the computer opens up the heating relay circuit and turns off the heating elements. When the temperature in the frying tub reaches about 232 °C (450 °F), a mechanical upper limit switch turns off power to heating elements. Staff should regularly check the individual upper-bound protection functions for correct functioning. The maintenance request card (MRC) 15 contains the associated method.
The analog control system does not have any timer functions. Shaking, removal and holding times (QA) must be monitored by the staff.


Oil is filled. See Section 3.1.
3. If the frying tub temperature is below 82 °C (180 °F), the controller automatically calls a preheating cycle (this is also often referred to as a melt cycle). The heating elements are repeatedly switched on and off so that the oil is heated gradually without burning. During the preheating cycle, the heating mode lamp lights up or illuminates. If the heating elements are turned on or off, switch off. The control unit will complete the preheating cycle within about 45 minutes, from which point onwards the heating mode lamp is illuminated constantly. 4. When the oil temperature has reached the temperature set by means of the control button, the heating elements AB and the heating mode light are switched off; this indicates that the frying machine is ready for starting the fries.



CHAPTER 4: FIELDING INSTRUCTION 4.1, introductory wording The FootPrint Pro filtering system allows the safe and efficient filtration of oil in a frying pan while keeping the other fry pans at one station operational. Section 4.2 deals with the preparation of the filter system for use. Section 4.3 deals with the operation of the system.


The filter tub runs on rollers in rails – like a kitchen drawer. The tub can be raised at the front to raise out the front rollers and thus the tub. Then pull the tub forward until the rear rollers run out of the rails.
Remove the crumb plate, hold-down ring, filter insert and filter sieve from the trough. Clean all metal parts with a solution of general purpose concentrate and hot water, then dry thoroughly.



Ensure that the sieve is inserted at the bottom and the bet with the rough side up the sieve. THE MISSION SHALL NOT: FILTER POWDER IS USED! 4. Slide the filter back into the frying tub so that it is positioned at the very rear of the cabinet. The filtration system is now ready for use. 4.3 Operation of the filter

Open the valve by turning the handle to the right.
Open the drain valve in the frying pan and allow oil to flow into the filter pan.


DO NOT use the cleaning rod to hammer on the drain valve or other objects. Damage to the ball valve will cause leaks and nullify Frymaster’s warranty.

Reset the filter handle to ON. 3. The filter pump pulls the oil through the filter insert and sieve, pumping it back through the frying tub in a 5-minute process called clarification. When clarification is carried out, the oil is purified by trapping solid particles in the filter.

Filter pump reset button




Attention to using McDonald’s all-purpose concentrate. Read the instructions for use and precautions before using them. Particular attention must be paid to the concentration of cleaner and duration of exposure to food contact surfaces. 5.1.1 Cleaning the inside and outside of the fryer cabinet – daily Clean the interior of the frying cabinet with a dry, clean cloth. Wipe all accessible metal surfaces and components to remove grease residue and dust. Clean the exterior of the frying cabinet with a clean cloth moistened with McDonald’s all-purpose concentrate. Wrap with a wet, clean cloth. 5.1.2 Cleaning of the built-in filter system – daily

5.1.4 Cleaning of the frying tub and heating elements – weekly

When the filter trough is empty, set one oil return handle after another on ON. Check if they are
Pump is activated and whether bubbles appear in the vegetable oil.
All oil return valves close (d). h Set all oil return handles OFF. The correct function
check the individual oil return valves by activating the filter pump with one of the oil return handle micro-switches. No air bubbles shall be present in the frying tray.
checking whether the filter trough is properly prepared for filtration, and
Discharge oil heated to 168 °C (168 °F) into the filter pan and close the frying pan drain valve. Set the oil return handle to ON. Allow all the oil to flow back into the frying tub (observed by blowing in the oil). Set the oil return handle OFF again. The frying tub should refill within a maximum of 2 minutes and 30 seconds.



OPERATORS
6.1.Introduction This chapter is a short troubleshooting guide for some problems that may occur while this frying machine is in operation. It is intended to help the user correct problems on this device or at least accurately diagnose them. While this chapter covers most common problems, it can also cause issues that are not covered here. In such cases, the Frymaster technical support staff will be happy to assist you in identifying and solving the problem. When trying to fix a problem, an elimination procedure should always be used, starting with the simplest solution up to the most complicated. Never overlook the obvious cause – it can easily happen that a power cord is not connected or a valve is not completely closed. But the most important thing is to get a clear idea why an issue occurred. Steps to ensure that this does not happen again must be part of any corrective action. If a controller does not work due to poor connection, all other connections must also be checked. If a fuse burns out again and again, the reason for this must be determined. Always note that the failure of a small component can often be an indication of possible failure or incorrect functioning of a more important component or system. Before calling a maintenance representative or the Frymaster HOTLINE (1-800-243-7937) perform the following tasks:

6.2 Troubleshooting 6.2.1 Control and heating problems
A. This frying machine has two
Power cable: One for control and one main power cord. If the power cable for the control is not connected, the control cannot be activated. Ensure that the power cord for control is connected and the disconnect switch is not triggered.
A. Power cable is not connected
Or isolating switch has fallen.
B. If available, a functional
Use the control instead of the suspect. If the backup control works correctly, order a new controller from FASC.
B. Control has failed.
Not activating.
C. If one of the components in
Power supply system (incl.) If the transformer and interface card) fails, the control does not receive power and cannot function. The determination of the failed component goes beyond the scope of this user manual. FASC will inform.
C. Power supply component or sectional
Job card has failed.
A. A drain safety switch
prevents the heating elements from being switched on when the drain valve is not completely closed. Check that the drain valve is completely closed.
A. The drain valve is open.
B. If available, a radio-
Use tion control instead of the suspect. If the backup control works correctly, order a new controller from FASC. Frying machine
B. Control has failed.
C. This frying machine has two
does not heat.
Power cable: One for control and one main power cable for 3 phases. If the power cable for control is connected but the main power cable is not connected, it seems that the controller works, but the frying machine cannot be heated. Check that the main power cable is securely connected and that the disconnector has not fallen.
C. Main power cable is not
connected.
Control can be

D. When the circuits are in
If the frying machine cannot determine the temperature of the fries tub, the heating element can not be activated – or it is deactivated if it was already activated. If the contactor, heating element or associated wiring fails, the heating element is not activated. The determination of the faulty component goes beyond the scope of this user manual. FASC will inform.
D. One or more other
Last page.
Components have failed.
This frying machine is equipped with a drain safety switch which prevents the heating elements from being turned on when the drain valve is not completely closed. Check that the drain valve is completely closed.
does not heat after filtration.
The drain valve is open.
If available, use a working control instead of the suspect. If the backup control works correctly, order a new controller from FASC. If replacing the control does not solve the problem, it is likely that the temperature probe has failed. FASC will inform.
Heats until the upper limit switch
Temperature probe or control has failed.
drops, the heating indicator being ON.
If available, use a working control instead of the suspect. If the backup control works correctly, order a new controller from FASC. If replacing the controls does not solve the problem, a closed contactor is likely to have failed. FASC will inform.
switch is dropped, the heating indicator being
The rifle or control is not working.
It's not ONE.

If the heating light is ON, this indicates that the control works correctly and requests heat output. The upper-bound thermostat is a normally closed switch. If the thermostat fails, the “switch” opens and power supply to heating elements is interrupted. If the contactor does not close, the heating elements are not supplied with current. The determination of the component that has fallen out goes beyond the scope of this user manual. FASC will inform. 6.2.2 Error messages and display problems
upper-bound thermostat or contactor has failed.
if the heat indicator is ON.
M2000 computers can be programmed to display temperatures in degrees Celsius or Fahrenheit. Instructions for switching the display to M2000 Computer Operation Manual (operating instructions for computers M2000) etake over.
A false display option has been programmed.
( Fahrenheit or Celsius).
The display is only shown when the frying machine in Non-dedicated The frying tub temperature increases by more than 8 °C (15 °F) above the programmed setpoint value. This indicates a problem in the temperature control circuits. Switch off the frying machine and notify FASC.
The temperature of the frying tub is more than 8 oC (15 oF) above the nominal value.
Shown HI.
This is an indication of a malfunction in the temperature control circuit, including failure of upper-boundary thermostat. Switch off the frying machine immediately and notify FASC.
The temperature of the frying tub is greater than 210 oC (410 oF) or in CE countries more than 202 oC (395 oF).
Shown HOT.

This indicator is normal when the frying machine is initially switched on and can be briefly displayed if a large amount of frozen product is placed in the fries tray. If the display does not go out, the frying machine will not heat. If available, use a working computer instead of the suspect. If the frying machine with the replacement computer is working correctly, order a new computer from FASC.
The temperature of the frying tub is between 82 °C (180 °F) and 157 °C (315 °F).
LOW TEMP.
This indicates a problem in the temperature measurement circuit that goes beyond the scope of operator trouble-finding. Switch off the frying machine and notify FASC.
Problem with the temperature measurement circuit, including probe.
SAMPLE FAILURE.
This indicates that the frying machine is not being heated. It is displayed if the frying machine cannot heat an oil. It also appears when the oil temperature is above 232 °C (450 °F) and the upper-bound thermostat has opened, stopping heating of the oil. Ensure that the drain valves are completely closed. If this does not correct the problem, FASC will notify.
M2000 display shows IGNITION FAILURE.
drain valve open, compter or transformer defective, upper-bound thermostat open.
This is only displayed during a test of the upper limit circuit and indicates that the upper limits switch has opened correctly.
Computer is in upper limit test mode.
HI-LIMIT.
This is only displayed during a test of the upper limit circuit and indicates that the upper limits switch has failed. DO NOT USE THE FROSTING TRAY! FASC will inform.
Computer is in upper limit test mode.
HI 2 BAD.
This is an indication of a malfunction in the temperature measurement or control circuit, including failure of upper-bound thermostat. Determining the specific problem goes beyond the scope of this operating manual. Switch off the frying machine immediately and notify FASC.
Oil temperature is above the permissible range or there is a problem with the temperature measuring circuits.
Analogue control fault light is ON.

Check that the drain valve is completely closed. The frying machine does not work if the drain valve is not completely closed. If the drain valve is completely closed, the problem lies in the locking circuit and the correction goes beyond the scope of this user manual. FASC will inform. 6.2.3 Filtering problems
The lamp is ON and the heater.
Open the drain valve or problem on locking circuits.
is ONE.
A. Check if the power cord
A. Power cable is not connected
Or isolating switch has fallen.
is connected. If yes, check if the disconnector has not fallen.
B. If the engine is too hot,
With fingers touched for more than a few seconds, the temperature protection switch was probably triggered. Allow the engine to cool for at least 45 minutes and press pump reset button.
B. Pump motor is overheated and has
thermal protection switch is triggered.
Filter pump does not start.
C. blockage in the filter pump.
C. Pump blocking shall be carried out in:
As a rule, this is caused by excessive deposits in the pump due to improperly dimensioned filter components or because the crumb sieve was not used. FASC will inform.
Test: Close the drain valve and pull the filter pan out of the frying machine. Turn on the pump. If the pump motor buzzes briefly and then stops, it is likely that the pump itself will be blocked.
blockage in the suction line of the filter trough.
The blockage can be caused by deposits or, when using solid fat, by fat hardened in the line. Remove the blockage with a thin, flexible wire. If the blocking cannot be removed, FASC will notify.
Filter pump running but does not supply oil
Test: Close the drain valve and pull the filter pan out of the frying machine. Turn on the pump. When air or bubble-containing oil emerges from the rear purge connection, the suction line of the filter pan is blocked.
the frying tub.
Analogue control

A. If a filter paper or
Filter insert configuration is used, check whether the filter screen sits at the bottom in the tub with the paper or filter insert on top of the screen.
Ensure that the O-rings are present and in good condition. They shall be fitted to the filter pan connection.
A. Incorrectly installed components of
Filter pan.
When using the Magnasol filter assembly, check whether the O-ring is present on the filter screen screwing and in good condition.
But it only slowly returns oil.
B. For proper filtration,
the oil or fat has approximately 177 oC (350 oF). At lower temperatures, the oil/fat becomes too thick to simply flow through the filter medium; this leads to a slower oil return and finally overheating of the filter pump motor. Ensure that the oil/fat is at approximately frying temperature before it is drained into the filter tub. 6.3 Replacement of the control or control wiring harness 1. Disconnect the frying machine from power supply, remove two screws in the upper corners of the control panel and unfold it from above; it shall rest on hinge tongues. 2. Disconnect the wiring harness at the rear of the control. When the cable harness is replaced, it must be disconnected from the interface card (see photo on next page). If the Control is exchanged, disconnect the ground cable and raise the control from the hinge slots in the operating panel frame. 3. Reversing this process to install a new controller or wire harness.
B. It is trying to make oil or fat.
filter that is not hot enough.

Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.