Electric Cooker Models 8SMS, 8BC and 8C Installation, Operation, Service, and Parts Manual

Frymaster, a member of the Commercial Food Equipment Service Association, recommends using CFESA Certified Technicians.
24-Hour Service Hotline 1-800-551-8633 FEB 11

WHAT IS COVERED This warranty covers all defects in workmanship and material in all commercial cooking appliances and computer/controller equipment manufactured by Frymaster and sold within the domestic United States, except as excluded below.
WHO IS COVERED This warranty covers only the original purchaser of Frymaster commercial cooking appliances and computer/controller equipment. This warranty is not trans ferable. You must have your original sales receipt for warranty coverage.
WHAT WE WILL DO We will repair or replace the defective appliance, component, or part. Such repair or replacement will be at the expense of Frymaster, LLC; except that travel over 100 miles or two hours, overtime, and holiday charges will be at the expense of the purchaser.
Stainless steel frypots on all fryers, except as noted below, are warranted against manufacturing defects and/or weld seam failure for the lifetime of the fryer; parts and labor, except after one year, the warranty is limited to replacement parts. Stainless frypots for models listed below are warranted for the length of time indicated.
1 Year 5 Years 7 Years 10 Years All Cold Rolled GF14, GF40 H55 (Effective Pasta Systems May 1, 1998) (Gas and Electric) Gas Protector Rethermalizer Water Bath Station (Gas and Electric)
H55 and gas Protector® combustion chamber (infrared burners and structural components to mount the burners) warranted against defective material or workmanship for 7 years, parts and labor.
FENWAL THERMOSTATS Warranted for two years, parts and labor, except after one year, the warranty is limited to replacement parts.
OTHER PARTS All other parts components are warranted for one year from the date of purchase (parts and labor).
SHORTENING DISPOSAL UNIT Warranted for 90 days parts and labor. In addition, the pump is warranted for one year, parts only.
REPLACEMENT PARTS Parts, 90 days, no labor Mild steel frypot, 90 days, no labor Stainless Steel frypots, 1 year, 90 days labor Computers, 1 year, no labor
HOW TO GET SERVICE Contact our Authorized Service Agent to obtain warranty service. To find the name and location of the nearest ASA call your dealer, or call the Frymaster Service Hotline, 800-551-8633. You can also go to the Frymaster website, www.frymaster.com click on Service, click on Locator, key in zip code and it will give you the ASA for that zip code. When calling for service, please furnish the model number, serial number, series code number, voltage of your appliance, and a description of the problem. You must keep your sales receipt for proof of your date of purchase.
WHAT THIS WARRANTY DOES NOT COVER THE WARRANTIES PROVIDED BY FRYMASTER, LLC DO NOT APPLY IN THE FOLLOWING INSTANCES:
+ Damage due to misuse, abuse, alteration, or accident. + Improper or unauthorized repair. + Failure to follow installation procedures, operation instructions and/or scheduled maintenance procedures as prescribed in your Frymaster
Service and Owner’s Manual. + Damage in shipment. + Removal, alteration, or obliteration of the rating plate. + Changes in adjustment and calibrations after thirty (30) days from equipment installation date. + Failure to program computer appliances in accordance with programming procedures prescribed in your Frymaster Service and Owner’s Manual. + Equipment exported to foreign countries. + Normal maintenance items such as electric bulbs, fuses, gaskets, o-rings, interior and exterior finishes. + Travel over 100 miles or two hours, overtime or holiday charges; all of which must be paid for by the purchaser. + Consequential damages (the cost of repairing other property which is damaged), loss of time, profits, use or any other non-fryer related inciden
tal damages of any kind.
GENERAL EXCLUSIONS No warranty is provided for any Frymaster fryer used in a mobile installation or concession. Warranty protection is only offered for fryers installed in accordance with the procedures described in the Frymaster Service and Owner’s Manual.
There are no implied warranties of merchantability of fitness for any particular use or purpose. This warranty is the only and complete statement with respect to warranties of your commercial cooking appliances and computer/controller equipment manufactured by Frymaster. There are no other documents or oral statements for which Frymaster will be responsible.
www.frymaster.com Frymaster Domestic

THIS EQUIPMENT IS INTENDED FOR INDOOR USE ONLY. DO NOT INSTALL OR OPERATE THIS EQUIPMENT IN OUTDOOR AREAS.
DO NOT OPERATE THIS EQUIPMENT WITHOUT FIRST READING THIS MANUAL.
DO NOT OPERATE THIS EQUIPMENT UNLESS ALL COVERS AND ACCESS PANELS ARE IN PLACE AND
PROPERLY SECURED.
DO NOT ATTEMPT TO REPAIR OR REPLACE ANY COMPONENT OF THIS EQUIPMENT UNLESS ALL
POWER TO THE UNIT HAS BEEN DISCONNECTED.
IF THE POWER SUPPLY CORD IS DAMAGED, IT MUST BE REPLACED BY THE MANUFACTURER OR ITS
SERVICE AGENT OR SIMILARLY QUALIFIED PERSONS IN ORDER TO AVOID A HAZARD.
USE CAUTION WHEN SETTING UP, OPERATING, OR CLEANING THIS EQUIPMENT TO AVOID CONTACT
WITH HEATED SURFACES.
DO NOT USE WATER JETS TO CLEAN THIS EQUIPMENT.
THIS EQUIPMENT IS TO BE INSTALLED IN COMPLIANCE WITH THE BASIC PLUMBING CODE OF THE
BUILDING OFFICIALS AND CODE ADMINISTRATORS INTERNATIONAL, INC. (BOCA) AND THE FOOD
SERVICE SANITATION MANUAL OF THE FOOD AND DRUG ADMINISTRATION.
PROPERTY DAMAGE, INJURY, OR DEATH. READ THE INSTALLATION, OPERATING, AND SERVICE
INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS EQUIPMENT.
IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.
FCC
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:
A device, it has been shown to meet the Class B limits.
This digital apparatus does not exceed the Class A or B limits for radio noise emissions as set out by the
ICES-003 standard of the Canadian Department of Communications.
Cet appareil numerique n’emet pas de bruits radioelectriques depassany les limites de classe A et B
prescrites dans la norme NMB-003 edictee par le Ministre des Communcations du Canada.
AND/OR BIRTH DEFECTS OR OTHER REPRODUCTIVE HARM. Operation, installation, and servicing of this product could expose you to airborne particles of glasswool or ceramic fibers, and/or crystalline silica. Inhalation of airborne particles of glasswool or ceramic fibers
is known to the State of California to cause cancer.
FRYMASTER FRYERS EQUIPPED WITH LEGS ARE FOR PERMANENT INSTALLATION. FOR MOVEABLE
OR PORTABLE INSTALLATION, FRYMASTER OPTIONAL EQUIPMENT CASTERS MUST BE USED.
QUESTIONS CALL 1-800-551-8633.
Do not use deliming solution to clean water bath units. Use of deliming solution will damage all stainless
steel parts.



6.4 Troubleshooting 6-11 6.4.1 How the Autofill System Works 6-11 6.4.2 How the Water Heating System Works 6-11 6.4.3 Technician Troubleshooting Guides 6-12 Troubleshooting the Autofill System 6-12 Troubleshooting the Basket Lift 6-13 Troubleshooting the Controller 6-14 Troubleshooting the Contactor Coil 6-15 Troubleshooting the High-Limit Thermostat 6-15 Troubleshooting the Temperature Probe 6-15 6.5 Wiring Diagrams 6-16 CHAPTER 7: Parts List
7.1 Accessories 7-1 7.2 Basket Lift Components 7-2 7.3 Cabinetry 7-4 7.4 Cookpot and Rinse Tank Components 7-6 7.5 Electrical Components and Controllers 7.8 7.6 Water Supply Components 7-9

CHAPTER 1: GENERAL INFORMATION
In order to assist you as quickly as possible, the Frymaster Factory Authorized Service Center (FASC) or Service Department representative requires certain information about your equipment. Most of this information is printed on a data plate affixed to the inside of the door. Parts orders may be placed directly with your local FASC or distributor. Included with cookers when shipped from the factory is a list of FASCs. If you do not have access to this list, contact the Frymaster Technical Service Department at 1-800-551-8633 or 1-318-865-1711. When ordering parts, the following information is required:
Model Number: Serial Number: Voltage: Item Part Number: Quantity Needed: Service information may be obtained by contacting your local FASC/Distributor. Information may also be obtained by calling the Frymaster Technical Service Department at 1-800-551-8633 or 1-318-865-1711. When requesting service, please have the following information ready:
Model Number: Serial Number: Voltage: In addition to the model number, serial number, and voltage, please be prepared to describe the nature of the problem and have ready any other information that you think may be helpful in solving your problem.
RETAIN AND STORE THIS MANUAL IN A SAFE PLACE FOR FUTURE USE.
Before attempting to operate your unit, read the instructions in this manual thoroughly. Throughout this manual, you will find safety notations enclosed in boxes similar to the ones illustrated below and on the following page.
in malfunction of your equipment.

result in damage to your equipment, and which may cause your equipment to
malfunction.
in injury to personnel, and which may cause damage or malfunctioning of your
Frymaster Electric Cookers are specifically designed to deliver high volumes of cooked or blanched food automatically. Model Comparison:
8SMS: The “Spaghetti Magic System” features an 8-kilowatt cooker and rinse tank combination. The 8.7-gallon (33-liter) cooker is equipped with a programmable computer that controls water temperature, water level, and cooking times. A swing-away water faucet is standard. Its automatic basket lift system submerges and extracts either bulk or individualized portions of pasta according to times programmed by the operator. Options include automatic water filling (AutoFill) and starch skimming (AutoSkim). The AutoFill feature maintains the cookpot water level approximately 1¼ inch (32mm) below the overflow drain. The AutoSkim feature sprays water onto the surface of the water, forcing starch to the overflow drain. This eliminates loss of cooking time associated with removing excess starch buildup. It also keeps the cooking water at the optimum level by replacing water evaporated during the cooking process. The AutoSkim function also saves energy since there is no need to reheat a refilled cookpot. The cookpot is safeguarded against over filling and boilover by a large overflow drain. “SD” following the model designation indicates a stainless steel cookpot and door, and an enameled cabinet. “SC” following the model designation indicates all stainless steel components.
8BC & 8C: These standalone cookers are essentially the same as the 8SMS, but without the built-in rinse tank. 8BC models have an automatic basket lift and optional automatic water filling and starch skimming. 8C models have no basket lifts and no automatic water filling and starch skimming options. The cookpot in both is safeguarded against over filling and boilover by a large overflow drain. “SD” following the model designation indicates a stainless steel cookpot and door, and an enameled cabinet. “SC” following the model designation indicates all stainless steel componentes.
1.4 Installation, Operating, and Service Personnel
Operating information for Frymaster equipment is intended for use by qualified and/or authorized personnel only, as defined in Section 1.5. All installation and service on Frymaster equipment must be performed by qualified, certi- fied, licensed, and or/authorized installation or service personnel, as defined in Section 1.5.
equipment

1.5 Definitions
QUALIFIED AND/OR AUTHORIZED OPERATING PERSONNEL Qualified/authorized operating personnel are those who have carefully read the information in this manual and have familiarized themselves with the equipment functions, or who have had previous experience with the operation of the equipment covered in this manual. QUALIFIED INSTALLATION PERSONNEL Qualified installation personnel are individuals, or firms, corporations, or companies that, either in person or through a representative, are engaged in and are responsible for the installation of electrical appliances. Qualified personnel must be experienced in such work, be familiar with all electrical precautions involved, and have complied with all requirements of applicable national and local codes. QUALIFIED SERVICE PERSONNEL Qualified service personnel are those who are familiar with Frymaster equipment and who are authorized by Frymaster to perform service on Frymaster equipment. All authorized service personnel are required to maintain a complete set of service and parts manuals and to stock a prescribed minimum amount of Frymaster parts. Failure to use qualified service personnel will void the Frymaster Warranty on your equipment. A list of Frymaster Factory Authorized Service Centers (FASCs) is included with the equipment when it is shipped from the factory. 1.6 Shipping Damage Claim Procedure
Your Frymaster equipment was carefully inspected and packed before leaving the factory. The transportation company assumes full responsibility for safe delivery upon acceptance of the equip- ment for transport. What to do if your equipment arrives damaged: 1. File a claim for damages immediately, regardless of the extent of damages. 2. Inspect for and record all visible loss or damage and ensure that this information is noted on the freight bill or express receipt and is signed by the person making the delivery. 3. Concealed loss or damage that was unnoticed until the equipment was unpacked should be recorded and reported to the freight company or carrier immediately upon discovery. A concealed damage claim must be submitted within 15 days of the date of delivery. Ensure that the shipping container is retained for inspection.
FOR DAMAGE OR LOSS INCURRED IN TRANSIT.

CHAPTER 2: INSTALLATION INSTRUCTIONS
PROPER INSTALLATION IS ESSENTIAL FOR EFFICIENT, TROUBLE-FREE OPERATION OF YOUR COOKER. ANY UNAUTHORIZED ALTERATIONS MADE TO THIS EQUIPMENT WILL VOID THE FRYMASTER WARRANTY. Upon arrival, inspect the equipment carefully for visible or concealed damage. (See Shipping Damage Claim Procedure in Chapter 1.) NATIONAL CODE REQUIREMENTS This equipment is to be installed in compliance with the Basic Plumbing Code of the Building Officials and Code Administrators International, Inc. (BOCA) and the Food Service Sanitation Manual of the U.S. Food and Drug Administration. ELECTRICAL GROUNDING REQUIREMENTS All electrically operated appliances must be grounded in accordance with all applicable national and local codes. A wiring diagram is located on the inside of the equipment door. Refer to the rating plate on the inside of the door for proper voltages. FCC COMPLIANCE The user is cautioned that any changes or modifications to Frymaster computers not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Frymaster computers have been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. While these devices are verified as Class A devices, they have been shown to meet the Class B limits. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of the equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. If necessary, the user should consult the dealer or an experienced radio and television technician for additional suggestions. The user may find the booklet “How to Identify and Resolve Radio-TV Interference Problems” helpful. It is prepared by the Federal Communications Commission and is available from the U.S. Government Printing Office, Washington, DC 20402, Stock No. 004-000-00345-4.

2.2 Caster/Leg Installation
Depending upon the specific configuration ordered, your unit might have been shipped without in- stalled casters or legs. If casters or legs are installed, you may skip this section and proceed to Sec- tion 2.3, Pre-Connection Preparations. If your unit requires the installation of casters/legs, install them in accordance with the in- structions included in your accessory package. 2.3 Pre-Connection Preparations
After the unit has been positioned in the area where it will be used, ensure the following have been accomplished before connecting the unit to the electrical power source:
(551.6 kPa). The maximum allowable incoming water temperature for all units is 180ºF (82ºC).

2.4 Connecting to the Electrical Power Supply

wire size, refer to the POWER REQUIREMENTS chart at the bottom of this page. 1. If the unit is not equipped with an installed power cord, open the door and remove the contactor box cover. Position the unit to gain access to the rear and remove the lower back panel. 2. Insert an appropriately rated power cord into the rear of the contactor box and make connections in accordance with the applicable wiring diagram on the following page. Install a strain relief on the power cord and replace the lower back panel and contactor box cover. 3. Attach a plug that complies with national and/or applicable local codes to the free end of the electrical power cord and plug the unit into an appropriate outlet.

SINGLE PHASE FIELD CONNECTION
SINGLE PHASE (NO NEUTRAL)
FIELD CONNECTION
NEUTRAL TO L3 L1 L2 L3
L1 L2 L3
1HV
1HV
1C1 2HV
FROM TRANSFORMER
FROM TRANSFORMER
1C1 2HV
3HV
3HV
FROM TRANSFORMER
FROM TRANSFORMER
3 PHASE 3 WIRE (DELTA) FIELD CONNECTION
3 PHASE 4 WIRE (WYE) FIELD CONNECTION
L1 L2 L3
L1 L2 L3
N
FROM TRANSFORMER
FROM TRANSFORMER FROM TRANSFORMER
1HV
3HV
1C1 2HV
1HV
2HV
3HV
1 2 5 3

CHAPTER 3: OPERATING INSTRUCTIONS
6 5 4 3 2 7 8 9
1 Numeric Keypad 6 Skim Switch (w/Autoskim only) 2 Boil Mode Indicator 7 Timer Start Switch 3 Boil Mode Switch 8 Simmer Mode Switch 4 Power Switch 9 Simmer Mode Indicator 5 LED Display 3.1 Introduction
The Spaghetti Magic II Controller allows the operator to specify a specific cook time in minutes and seconds, then initiate a cooking cycle. This controller is available in three different configurations. The standard configuration has both automatic filling (Autofill) and automatic skimming (Autoskim) features. Options include Autofill only, or neither Autofill or Autoskim. On units configured with the Autoskim feature, the operator may activate or deactivate the feature as desired. When in the BOIL mode, the heating element is energized at all times. It is used when actually cooking pasta. The SIMMER mode feature maintains the water temperature just below boiling, which conserves energy and water. This feature is designed for rethermalizing previously cooked packaged products, and for keeping the cooker in standby. The SKIM feature, when selected, adds water for approximately 3 seconds once a minute. It causes the water to overflow into the drain, carrying floating starch with it. (A buildup of starch reduces the effi-

ciency of the cooker and can cause erroneous temperature and water level sensing. NOTE: Do not use deliming solution to clean these units. Use of deliming solution will damage all stainless steel parts.)
LOW WATER SENSING automatically de-energizes the heating element if the water in the cook- pot drops too low. When the water level in the cookpot is below the low-water sensor, such as when draining and cleaning the cookpot, the controller display will read LO. NORMAL WATER LEVEL SENSING, on units configured with the Autofill feature, automatically adds water during or after a cooking cycle if the water in the cookpot drops to a level lower than ap- proximately 1¼ inch (32mm) below the overflow drain. With this automatic filling feature, the water level does not have to be continuously monitored. The cookpot always has the correct amount of water. 3.2 Operating Instructions
Before turning the cooker on, ensure that:

1. Turn the controller on by pressing the Power switch. 2. The unit will automatically enter the boil mode and the boil mode indicator will illuminate. If you do not intend to immediately begin cooking, press the Simmer Mode switch. The sim- mer mode indicator will illuminate. To re-enter the boil mode, press the Boil Mode switch. 3. Enter the desired cooking time using the numeric keypad. The time entered appears in the LED display. 4. When ready to initiate a cooking cycle, press the Start Timer switch. The basket lift will automatically lower the basket or portion cups into the cookpot and the LED display will begin to count down. At the end of the cooking cycle, an alarm will sound briefly to alert you and the basket lift will automatically raise the basket or portion cups out of the water.
The display will automatically return to the previously set cooking time. If the same time is de- sired for the next batch, simply press the Start Timer switch when ready, otherwise enter the new cooking time before pressing the switch. 5. To initiate the automatic skimming (Autoskim) feature, press the Skim switch.

3.3 Toggling Between Fahrenheit and Celsius Temperature Display There are two versions of the SMS Controller: one that can be toggled between Fahrenheit and Celsius temperature display, and one that cannot. To determine which version you have, turn the controller off by pressing the ON/OFF switch. The display will go blank. Press the Simmer (right thermometer icon) switch. If Code appears in the display, the temperature display can be changed. If not, the display cannot be changed. 1. If Code appears in the display, press 1, 6, 5, 8. The display will be toggled from Fahrenheit to Celsius or from Celsius to Fahrenheit. 2. Press the Boil (left thermometer icon) switch to display the cookpot temperature. If an F follows the temperature, the display is in Fahrenheit; if a C follows the temperature, the display is in Celsius. 3.4 Shutting the Cooker Down Turn the unit off by pressing the Power switch. If shutting down at the end of the day, drain and clean the cookpot (and rinse tank, if so equipped), and put the cookpot and rinse tank covers in place. 3.5 Boiling Out the Cookpot To ensure that the cooker is free of contamination from manufacture, shipping, or handling during installation, the cookpot must be boiled out before first use. 1. Close the drain valve and fill the cookpot with a solution of cold water and 1 cup of detergent.
limit thermostat capillary tube.

CHAPTER 4: PREVENTIVE MAINTENANCE
4.1 Daily Preventive Maintenance
It is normal for a coating of starch to form on the elements, sensors, and temperature probes during operation. If the coating is allowed to build-up, it will adversely affect the operation of the equipment. The preventive maintenance routines below should be performed at least daily to keep your equipment functioning at peak efficiency. The cookpot and rinse tank – especially the water- level sensors, temperature probe, and element – may require more frequent cleaning, depending upon the product and volume. NOTE: Do not use deliming solution to clean these units. Use of deliming solution will damage all stainless steel parts. Inspect Equipment and Accessories for Damage
Look for loose or frayed wires and cords, leaks, foreign material in cookpot or inside cabinet, and any other indications that the equipment and accessories are not ready for safe operation. Clean Cabinet Inside and Out
Clean inside the cabinet with a dry, clean cloth. Wipe all accessible metal surfaces and components to remove accumulations of oil, dust, or cooking residue.
Clean the outside of the cabinet with a clean cloth dampened with dishwashing detergent, removing oil, dust, or cooking residue.
cookpot is filled with hot water and/or food products. Clean Water-Level Sensors, Temperature Probe, Element, Cookpot, and Rinse Tank
Turn the equipment off and drain the cookpot (and rinse tank, if so equipped).
Remove the probe cover and clean the water-level sensors and temperature probe using a Scotchbrite™ or similar abrasive pad and a solution of detergent and water.
Using a Scotchbrite™ or similar abrasive pad and a solution of detergent and water, clean the inside of the cookpot (and rinse tank, if so equipped). Pay particular attention to the heating element. Rinse the cookpot (and rinse tank, if so equipped) thoroughly with clean water at least twice.
damage all stainless steel parts.
high-limit thermostat capillary tube.

4.2 SMS II Controller Simmer Mode Adjustment
NOTE: The SMS II Controller simmer temperature is adjustable from 185ºF to 215ºF. 1. With the unit in the simmer mode, place the tip of a good grade thermometer near the temperature probe and determine the actual water temperature in degrees Fahrenheit. If the temperature is within 5ºF of the desired simmer temperature, nothing more needs to be done. If it is not within 5ºF of the desired temperature, perform Steps 2 through 5. 2. With the unit in the simmer mode, open the control panel by removing the screws in the upper corners and tilting the panel out. 3. Remove the black rubber plug from the top of the controller housing. 4. Using a small, flat-tipped screwdriver, turn the adjusting screw to change the simmer setpoint. ¼ turn will change the setpoint about 10ºF. (You will have to experiment with the direction of rotation to determine which way to turn to raise or lower the temperature.) Wait at least 5 minutes, then recheck actual water temperature. Repeat this step until the water temperature is within 5ºF of desired temperature. 5. Replace the plug in the controller, close the control panel, and replace the screws removed in Step 1.

CHAPTER 5: OPERATOR TROUBLESHOOTING
This chapter provides an easy reference guide to the more common problems that may occur during the operation of this equipment. The troubleshooting guides in this chapter are intended to help you correct, or at least accurately diagnose, problems with the equipment. Although the chapter covers the most common problems reported, you may very well encounter a problem not covered. In such instances, the Frymaster Technical Service Department will make every effort to help you identify and resolve the problem. When troubleshooting a problem, always use a process of elimination starting with the simplest solution and working through to the most complex. Never overlook the obvious. Anyone can forget to plug a cord into a receptacle or open the valve on the water supply line. Don’t assume that you are exempt from such occurrences. Most importantly, try to establish a clear idea of why a problem has occurred. Part of your corrective action involves taking steps to ensure that it doesn’t happen again. If a controller malfunctions because of a poor connection, check all other connections while you’re at it. If a fuse continues to blow, find out why. Keep in mind that failure of a small component may often be indicative of potential failure or incorrect functioning of a more important component or system. Some of the troubleshooting actions recommended in this chapter involve removing suspect controllers and substituting controllers that are known to be good. Whenever this is indicated, refer to Section 5.3. Refer to Section 5.4 for instructions on replacing fuses. If you have doubts as to the proper action to take, do not hesitate to call the Frymaster Technical Service Department or your local Frymaster Factory Authorized Service Center for assistance. Before calling a servicer or the Frymaster HOTLINE (1-800-551-8633):
water or to transfer hot water from one container to another.
exposed.
qualified service personnel. The equipment should be unplugged when servicing,
except when electrical tests are required. 5.2 Operator Troubleshooting Guides

NOTE: IF AUTOFILL WORKS
BUT AUTOSKIM DOES NOT,
COOKPOT DID NOT FILL
WHEN UNIT WAS TURNED ON. WATER
PROBLEM IS A FAILED CONTROLLER. ORDER REPLACEMENT FROM FASC
SUPPLY TO UNIT VERIFIED TO BE ON.
OR DISTRIBUTOR.
Did anything appear in controller display when unit was
level sensors.
Disconnect unit from electrical power. Check
the left 5-amp fuse in component box. Replace fuse if blown then attempt
to operate.
Is another controller, known
Problem is beyond the scope of operator troubleshooting. Call
Substitute the controller known to be working for the suspect controller and
Problem resolved. Yes
FASC.
attempt to operate unit.
Probable causes are shorted upper water level sensor, failed
water solenoid, or loose/ damaged wiring. Call FASC.
Problem is a failed
controller. Order replacement from FASC or distributor.

Operator Troubleshooting Guides (Continued)
NOT SHUT OFF WHEN
COOKPOT WAS FULL.
level sensors.
Problem resolved.
Add 1/8-cup of baking soda to the
water in the cookpot and stir.
Mineral content of water is insufficient for water sensor to ground. Whenever cookpot is
refilled, add 1/8-cup of
baking soda.
Probable causes are a loose or damaged wire on the upper water level sensor, a failed water solenoid,
or a failed upper water level sensor.
Call FASC.

Operator Troubleshooting Guides (Continued)
BOIL. COOKPOT VERIFIED TO BE FULL OF WATER WITH BOIL MODE SELECTED (i.e.,
left indicator is lit).
Is heating indicator (small
Probable causes are a failed element, failed contactor,
or loose/damaged wiring.
Call FASC.
Substitute the controller known to be working for the suspect controller and
Is a controller known to be working
attempt to operate unit.
Problem is a failed controller. Order replacement from FASC
or distributor.
Problem is beyond the scope
of operator troubleshooting.
Call FASC.

Operator Troubleshooting Guides (Continued)
IN SIMMER
MODE.
accordance with procedure in Chapter 4.
stop? Problem resolved. Yes
Substitute the controller known to be working for the suspect controller and
Is a controller known to be working
attempt to operate unit.
Problem is beyond the scope
Problem is a failed controller. Order replacement from FASC
of operator troubleshooting.
Call FASC.
or distributor.
Probable cause is a failed/ shorted temperature probe.
Call FASC.

Operator Troubleshooting Guides (Continued)
IS TOO LOW IN SIMMER MODE.
accordance with procedure in Chapter 4.
Did water reach correct temperature?
Problem resolved.
Is a controller known to be working
known to be working fo the suspect controller and
attempt to operate unit.
Did water reach correct temperature?
Problem is a failed controller. Order replacement from FASC or
distributor.
Probable cause is open temperature probe or loose
probe wire. Call FASC.

Operator Troubleshooting Guides (Continued)
NOT FUNCTION
CORRECTLY.
Did the basket lift function
Check the right-side 5-amp fuse. Replace if blown, then attempt to
operate unit.
Did the basket lift function
Problem resolved.
Does the basket lift travel
Probable causes are a failed microswitch or a microswitch
that is out of adjustment.
Call FASC.
If the basket lift works sometimes but not always, the probable causes are a loose bell crank or a loose
microswitch. Call FASC.
If the movement of the basket lift is jerky or noisy, lubricate
the lifter rod with a light-weight lubricant. if this does not
correct the problem, call FASC.

5.3 Replacing the Controller or Controller Wiring Harness 1. Disconnect the cooker from the electrical supply. 2. Remove the two screws in the upper corners of the control panel and swing the panel open from the top, allowing it to rest on its hinge tabs. 3. Disconnect the wiring harness from the back of the computer. 4. Disconnect the ground wire from the computer. Remove the controller by lifting it from the hinge slots in the frame. 5. Reverse the procedure to install a new computer or wiring harness.

5.4 Replacing Fuses 1. Disconnect unit from electrical power and remove the cover from the contactor box located in the left front bottom of the cabinet. 2. The 5-amp fuse for the controller is located on the left side of the box. The 5-amp fuse for the basket lift is located on the right side of the box. Use a fuse puller to remove the blown fuse and install the replacement.
LINE 208/240V
Basket Lift Fuse (Present in 8SMS and 8BC units only.)

CHAPTER 6: SERVICE PROCEDURES
6.1 Functional Description of Electric Cookers 8SMS, 8BC and 8C Electric Cookers 8SMS, 8BC, and 8C contain an extruded stainless steel cookpot that holds 8.7 gallons (33 liters) of water. The water in the cookpot is heated by an 8-kilowatt element at the bottom of the pot. The solid-state SMS II Spaghetti Magic controller controls electrical power to the element. The 8SMS also has an 8.7 gallon (33 liter) rinse tank. On units without the Autofill (automatic filling) option, when the controller is turned on by pressing the Power switch, logic circuits in the controller check for water in the cookpot by looking for a grounded low-water level sensor. (The sensor is grounded by contact with the water in the cookpot.) If the sensor is grounded, the controller automatically enters the BOIL mode, supplying continuous power to the element. If the operator selects the SIMMER mode, logic circuits in the controller monitor the temperature of the water and cycle power to the element on and off to maintain the temperature at the simmer mode setpoint. (See Section 4.2 in Chapter 4 for instructions for adjusting the simmer mode setpoint.) The cooker also has a high-limit safety. If the water in the cookpot falls below the low-water level sensor but the sensor remains grounded for whatever reason, the high- limit switch will open, cutting off power to the element, when the element temperature reaches 400 ±15ºF. On units equipped with the Autofill option, a logic circuit in the controller automatically opens a solenoid valve on the water supply line if the upper water level sensor is not grounded by contact with the water in the cookpot. When the Power switch is pressed, if the water level is below the upper water level sensor, water is automatically added to the cookpot. When sufficient water has been added to cover the heating element, the unit automatically enters the BOIL mode and remains there unless the operator presses the SIMMER mode switch or turns the unit off. When the water level in the cookpot contacts the upper water level sensor, the solenoid valve in the water supply line closes. On units equipped with the Autoskim (automatic skimming) option, when the Skim switch is pressed, a logic circuit in the controller automatically opens the solenoid valve in the water supply line for three seconds every minute until the option is turned off by again pressing the Skim switch. The operator enters a specified cooking time by pressing the number pads on the controller. When the Start switch is pressed, the controller begins to count down to zero. When the controller times out, an alarm sounds briefly, then the timer reverts to the last time entered. On units equipped with basket lifts (8SMS or 8BC), when the Start switch is pressed to start the cooking cycle, logic circuits in the controller activate the basket lift motor, lowering the baskets into the cookpot. As the motor drives the basket lift down, a roller-activated switch loses contact with the bellcrank (cam) attached to the motor and power to the motor is cut. When the controller times out, logic circuits reverse the switch positions so that the motor circuit is again completed and the motor is restarted, raising the baskets from the cookpot. At the fully raised position, the roller switch again makes contact with the cam, cutting power to the motor and stopping the lift in the up position.

6.2 Accessing Equipment for Servicing
this equipment for servicing. 1. Disconnect the unit from the electrical power supply and from the water supply. 2. Remove any attached restraining devices. 3. Relocate the unit for service accessibility. 4. After servicing is complete, reconnect the unit to the water supply, reattach restraining devices, and reconnect the unit to the electrical power supply. 6.3 Replacing Equipment Components 6.3.1 Replacing the Controller See Section 5.4. 6.3.2 Replacing the Transformer, Basket Lift Relay, Contactor, or Solenoid Valve 1. Drain the cookpot and disconnect the cooker from the electrical power supply. 2. Remove the cover from the component box. (It may be helpful to remove the drain plumbing below the drain valve to better access the interior of the component box.) 3. On the component to be replaced, make a note of the wiring connection points. 4. Disconnect the wires and remove the failed component (see illustration on next page). Install the replacement component and reconnect the wiring in accordance with the notes made in Step 3 or with the wiring diagram on the door of the unit. 5. Replace the component box cover, being sure to reconnect the ground wire. Replace any drain plumbing components that were removed and reconnect the cooker to the electrical power supply.


Basket Lift Relay (8SMS, 8BC only)
Contactor Block (all units)

System Fuse and Holder (all units)
6.3.3 Replacing the Element 1. Drain the cookpot and disconnect the cooker from the electrical power supply. 2. Remove the cover from the component box. (It may be helpful to remove the drain plumbing below the drain valve to better access the interior of the component box.) 3. Make a note of where the leads are connected to the contactor block, then disconnect the leads. 4. Cut the wire ties on the fiberglass insulation and remove the insulation from the element leads. 5. Cut the metal wire ties that secure the high-limit thermostat to the element, being careful not to bend the thermostat. 6. Remove the brass nuts from the element legs and carefully pull the failed element from the cookpot.
Secure the high-limit thermostat along the inside of this leg with two metal wire ties.
29-inch (73.7 cm) leads shown shortened for clarity.
Standoff · Teflon Washer · Brass Nut

7. Position the replacement element in the cookpot with the standoffs on the bottom of the cookpot, and thread the element leads through the Teflon washers recovered from the failed element. Secure the element in place with the nuts removed in Step 5. 8. Install two metal wire ties to secure the high-limit thermostat against the inside of the left leg of the element. 9. Thread each set of element leads through the fiberglass insulation removed in Step 4 and secure the insulation in place with a wire tie as close as possible to the brass nut. 10. Thread one set of leads into the component box and connect them to the contactor block in accordance with the notes made in Step 3 or the wiring diagram on the door. NOTE: The leads are numbered to facilitate making proper connections. Repeat this step for the remaining set of leads. 11. Replace the cover on the component box, being sure to reconnect the ground wire. Reinstall any drain plumbing components that were removed, and reconnect the unit to the electrical power supply. 6.3.4 Replacing the High-Limit Thermostat 1. Drain the cookpot and disconnect the cooker from the electrical power supply. 2. Cut the metal wire ties securing the thermostat body to the element. 3. Open the control panel by removing the screws in each upper corner. Mark and then disconnect the two leads connected to the thermstat terminals.
Mark and disconnect wires from
the thermostat terminals.
Remove the two screws securing the
thermostat to the mounting bracket.
Loosen the small compression nut, then unscrew the large fitting from the cookpot.

4. Loosen the small compression nut, then unscrew the large fitting from the cookpot. 5. Remove the two screws securing the thermostat to the mounting bracket. (NOTE: It is not necessary to remove the bracket.) Pull the thermostat from the cookpot. 6. Carefully insert the replacement thermostat into the cookpot, being careful not to bend the shaft. 7. Position the thermostat along the inside of the left leg of the element and secure it in place with two metal wire ties. 8. Unscrew the small compression nut from the large fitting on the replacement thermostat. Apply thread sealer to the large fitting and screw the fitting securely into the cookpot. When the large fitting is tight, screw the small compression nut into the large fitting and tighten. 9. Coil the thermostat capillary tube as necessary to achieve a neat installation and attach the terminal block to the mounting bracket using the screws removed in Step 5. 10. Reattach the leads disconnected in Step 3, being sure to reconnect them in accordance with the wiring diagram on the door of the unit or the markings made when they were disconnected. 11. Return the control panel to the closed position and secure in place with the screws removed in Step 3. 12. Reconnect the unit to the electrical power supply. 6.3.5 Replacing a Water Level Sensor or the Temperature Probe 1. Drain the cookpot and disconnect the cooker from the electrical power supply. 2. Remove the basket lift arm by lifting it straight up from the lifter rod. Remove the probe cover by lifting it straight up from the probe block.
If replacing a water level sensor:
Remove the retaining screw from the sensor flange and pull the sensor from the probe block.
Disconnect incoming water lines from nipples.
Remove its Keps nut to disconnect the lead.
If replacing the temperature probe:
Mark the wiring harness leads and disconnect the probe leads at the push on connectors.
Remove the screws from the probe bracket and push the probe out the back of the probe block.
Remove these two screws and remove the access panel.

a. Disconnect the lead by removing the keps nut holding it in place. b. Remove the screw in the sensor flange. c. Carefully pull the failed sensor from the probe block and replace with the new sensor. d. Reattach the lead and reverse Steps 1-3 to complete the procedure. 5. If replacing the probe:
a. Mark the wiring harness leads and disconnect them from the probe leads at the push-on
connectors. b. Remove the two screws in the probe bracket. c. Carefully pull the probe from the probe block and replace with the new probe. d. Reattach the leads and reverse Steps 1-3 to complete the procedure. 6.3.6 Replacing the Pressure Regulator 1. Drain the cookpot and disconnect the cooker from the electrical power supply. 2. Turn off or disconnect the water supply to the cooker. Disconnect the incoming water line where it connects to the cooker. 3. At the rear of the unit, remove the two screws securing the access panel in place and pull it back over the water lines sufficiently to allow access to the connections inside.
Disconnect incoming water lines from nipples.
Loosen this compression fitting.
Remove these two screws and
remove the access panel. 4. At the regulator, loosen the compression fitting on the water line to the solenoid valve. Loosen the compression fitting at the faucet inlet manifold. Remove the regulator from the unit. 5. Recover the fittings from the failed regulator and install them on the replacement using thread sealer on all connections. 6. Reverse Steps 1-4 to reinstall the regulator, being sure to apply thread sealer to all connections. 7. Adjust the regulator to not more than 40 PSI (2.8 Kg/cm2) (275.79 kPa).
Loosen this compression fitting.

6.3.7 Replacing the Water Faucet 1. Drain the cookpot and disconnect the cooker from the electrical power supply. 2. Turn off the water supply to the cooker. 3. Disconnect the incoming water lines at the nipples that protrude from the holes in the upper access panel. If necessary, remove any quick-disconnect fittings that would prevent the access panel from being removed. Remove the two screws securing the access panel in place and remove the panel (see illustration above). 4. If the cooker is equipped with a pressure regulator, disconnect the regulator by loosening the compression fitting on the outlet side (see illustration in Section 6.3.6 above).
Remove the five screws in the mounting plate and lift the faucet and
plate clear of the unit.
Loosen these fittings to separate the faucet from the water supply system.
Remove jamb nut and washer to separate the faucet from the mounting plate.

8. Assemble the replacement faucet to the mounting bracket and complete the procedure by reversing Steps 1-6. 6.3.8 Replacing the Cookpot or Rinse Tank 1. Disconnect the unit from the electrical power supply and from the water supply. 2. Remove the cover from the component box, mark the element leads, disconnect them from the contactors, and pull them out of the component box. 3. Remove the top cap to expose the pot hold-down bracket assembly. Remove the two Keps nuts attaching the assembly to the cookpot or rinse tank. Loosen but do not remove the screws in the top of the bracket. Remove the two screws attaching the bracket to the cabinet frame and remove the bracket assembly from the unit. On units with a rinse tank, remove the screw securing the connecting strip.
Remove screw in each corner and remove top cap.
connecting strip.

Remove Keps nuts.
Disconnect incoming water lines from nipples.
Remove Keps nuts to disconnect the sensor leads.

disconnect the probe leads at the
Remove these two screws and
remove the access panel.
push on connectors.
Remove screw from

Disconnect at this compression fitting. 6. Remove the screws securing the fluecap assembly to the back panel of the cabinet and remove the assembly from the unit. On 8SMS units, remove the connecting strip disconnected in Step 4.
Remove the screws securing the flue
cap to the back panel of the cooker.

6.3.9 Replacing the Basket Lift Motor and Related Components 1. Disconnect the unit from the electrical power supply and dismount the basket lift arm. Attach a pair of Vise Grip™ pliers (or a similar locking device) to the basket lift rod where it protrudes from the cabinet to prevent it from sliping back down into the cabinet when the basket lift link is disconnected from the bellcrank. 2. Remove the lower basket lift access panel. 3. Mark and disconnect the wires attached to the microswitch. Disconnect the white motor wire at the inline connector. Cut wire tie, if present, and carefully push all wires back into the cabinet through the holes in the motor mount.



6.4 Troubleshooting 6.4.1 How the Autofill System Works The heart of the automatic filling (AutoFill) system is a normally closed solenoid valve that opens when 24VAC is applied. When the controller is turned on, it checks to see if the upper water level sensor is grounded by contact with water in the cookpot. If it is not, circuitry in the controller forms a ground for the 24VAC supplied to the solenoid, allowing the valve to open. When the water level in the cookpot reaches the upper water level sensor, the sensor is grounded, causing the controller to break the solenoid ground, thus shutting off the inflow of water. Starch or lime build-up on the upper water level sensor may keep the ground from forming, therefore the sensor must be kept clean and its lead firmly connected. NOTE: Do not use deliming solution to clean these units. Use of deliming solution will damage all stainless steel parts. This unit will not operate with distilled water. Pure water is non-conductive, so the required ground cannot be formed. If highly filtered or purified water is used, adding ⅛-cup of baking soda to the water will usually provide sufficient mineral content for the ground to form. NOTE: In units equipped with the AutoSkim feature, when the skim switch on the controller is pressed, a logic circuit in the controller automatically interrupts the 24VAC ground for three seconds every minute until the switch is again pressed. Therefore, failure of the AutoSkim feature will be due to a malfunctioning controller and not the solenoid valve. 6.4.2 How the Water Heating System Works To prevent energizing the heating elements when there is no water in the cookpot, these units are equipped with a low-water level sensor that must be grounded by contact with the water in the cookpot before the control circuitry will apply power to the elements. Starch or lime build-up on the low-water level sensor may keep the ground from forming, therefore always make sure the sensor is clean and its lead is firmly connected. NOTE: Do not use deliming solution to clean these units. Use of deliming solution will damage all stainless steel parts. The units will not operate with distilled water since pure water is non-conductive. In order for the ground to form, there must be some mineral content in the water. If highly filtered or purified water is used, add ⅛-cup of baking soda to the water each time the cookpot is emptied and refilled. In addition to the low-water level sensor discussed above, the water heating system has five more parts: the high-limit thermostat, the temperature probe, the contactor block, the element, and the controller. The high-limit thermostat functions as a normally closed switch. If the water in the cookpot falls below the low-water level sensor but the sensor remains grounded for whatever reason, the high- limit switch will open when the element temperature reaches 400ºF ±15 (204ºC ± 9), cutting off power to the contactor coil and thus to the element. The temperature probe is used only when the unit is in the simmer mode. When the operator selects the simmer mode, logic circuits in the controller monitor the temperature of the water and cycle power to the element on and off to maintain the temperature at the setpoint programmed into the controller.

The contactor block is the terminal block to which the element leads are connected and where actual contact is made between the leads and the line voltage. Built into the contactor block is a coil (electronic switch) that closes when a ground for the 24VAC from the transformer is supplied by the controller calling for heat. When it closes, contact is made between the incoming line voltage and the element leads. The element is a resistive heating device. That is, when voltage is applied to the element, the element gets very hot due to its resistance to current flow through it. The heat generated is transferred directly to the water in which the element is immersed. The controller is the interface between the operator and the other components of the equipment. In the water heating system, its function is to control the application of line voltage to the heating element via the contactor coil. Troubleshooting the water heating system consists of checking the above components for proper operation, as detailed in the troubleshooting diagrams on the next page. 6.4.3 Technician Troubleshooting Guides
THE AUTOFILL
SYSTEM
Solenoid valve does not close
when water is below upper water
when water reaches upper water level sensor.
level sensor.
Is 24VAC present at pin 6
Is 24VAC present at pin 6
Valve has failed.
Replace.
Check for shorting of sensor to ground. If
Problem resolved. Yes
a scouring pad.
sensor is not shorted,
computer has failed.
Replace.
Probable cause is loose/broken wiring or damaged sensor. No
Add 1/8 cup baking soda to
Computer has failed. Replace.
water and stir.
Substitute a controller known to
Yes No Is AutoFill functioning
Problem resolved.
be working for suspect controller.

Technician Troubleshooting Guides (Continued)
If the basket lift motor is activating, but the basket lift fails to raise or lower, or if its movement is erratic, the probable cause is jamming or binding of the basket lift rod. Apply a light-weight white grease (such as LubriplateTM ) to the rod. If this does not correct the problem, check for a bent or otherwise damaged rod and link, and for a loose bellcrank.
THE BASKET LIFT
Is 3-Amp fuse in the component box
Replace fuse. No
With the basket lift in the UP position, is 13-17VDC present at pin 10 of 15-pin plug (0
Probable cause is a
failed controller. No
volts if in DOWN position)?
With the basket lift in the UP position, is 13-17VDC present at relay terminal A (0 volts
Probable cause is failed/loose wiring. No
if in DOWN position)?
With the basket lift in the UP position, is line voltage present at the NC (lower) terminal of the
Probable cause is a
failed relay. No
microswitch (middle terminal if in
With the basket lift in the same position as for the previous check, is line
Probable cause is a
failed switch. No
voltage present at the Common (upper)
Probable cause is a
failed motor.

Technician Troubleshooting Guides (Continued)
THE CONTROLLER
Are the fuses in
Replace fuse. No
Is 24VAC present on transformer secondary?
Is 24VAC present at pin 1?
No No Replace transformer.
Is 24VAC present at pin 4 when off and zero VAC when calling for
Is 24VAC present at pin 6 when not filling and is pin 6 grounded
Replace controller. No
On 8SMS and 8BC units, is 13-17VDC present at pin 10 when lift is in UP position
and zero VDC when lift is in DOWN
On 8SMS and 8BC units, is 13-17VDC present at pin 12?
Is 2-3VDC present at pin 13? Yes Controller is OK. Yes

Technician Troubleshooting Guides (Continued)
Before performing the following checks, disconnect the unit from the electrical power source and check all wiring connections involved to ensure they are secure.
Each of the following checks is to be performed with the unit connected to the electrical power supply, with the controller on and calling for heat, and with enough water in the cookpot to cover the lower water level sensor.
TROUBLESHOOTING
THE HIGH-LIMIT
THE TEMPERATURE
THERMOSTAT
PROBE
Is 24VAC present at the C
problem? Water boils in simmer mode.
High-limit has failed. Replace.
is too low in simmer mode.
Check for shorted probe circuit. Probe voltage at pin 13 should be: Approx 1.8VDC @ 60ºF (16ºC) Approx 2.0VDC @ 100ºF (38ºC) Approx 2.5 VDC @ 212ºF (100ºC) Probe resistance should be: Approx 552 ohms @ 60ºF (16ºC) Approx 655 ohms @ 100ºF (38ºC) Approx 1000 ohms @ 212ºF (100ºC)
High-limit is OK.
of probe.
Continuity OK? Probe is OK.
Calibrate controller. Yes Yes
THE CONTACTOR
Probe is shorted.
Probe is open.
Replace.
Replace.
Is 24VAC present at pin 4 of the 15- pin plug when controller is
Is button in the center of the contactor
failed. Replace. No
Contactor coil is OK. Element has
failed controller.
failed. Replace.

6.5 Wiring Diagrams

ALL READINGS REFERENCED TO GROUND WITH THE COMPUTER OPERATING

SOUND DEVICE
BASKET LIFT SHOWN
IN UP POSITION
43C 44C
N.C. N.O.
GM
NC
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
MOTOR
SWITCH
PROBE
13C 14C
TEMPERATURE
GEAR
MICRO
1 2 5 3 4 6 TEMP.
TEMPERATURE
2 TO 3 VOLTS DC
DEPENDING
ON THE
WATER
NC
NO
1C 2C 4C 7C 9C 10C 12C
13 TO 17 VDC
VRELAY
WHEN SOUNDING
A B
24 VAC 24VDC
3 TO 5 VOLTS
BASKET LIFT
SD
0 VOLTS WHEN BASKET IS DOWN
13 TO 17 VDC WHEN BASKET
COM
24C 11C
WATER
SENSOR
IS UP
SENSOR HIGH
WATER LEVEL PROBES DO NOT MEASURE
OPTIONAL
AUTOFILL
480/120VAC DUAL VOLTAGE CONFIGURATION
NC
COMPUTER CONTROL
WATER
LOW
GROUND WHEN
SOLENOID
FILLING 24VAC
ALL READINGS REFERENCED TO GROUND WITH THE COMPUTER OPERATING
NC WATER
FILL
WHEN NOT
FILLING
WHEN HEATING
NO VOLTAGE
24VAC WHEN OFF
NC HEAT
HIGH LIMIT
CONTACTOR
COIL
HOT COM
24VAC GND.
8050462C
N.C.
TRANSFORMER
LOAD
24VAC 50 VA.
120 VAC
IN-LINE SPLICE
TYPE 3AG
FUSE
GRN
5 AMP
120 VAC CORDSET
WHITE
BLACK
1HV 2HV 3HV
1C1 1C2 1C3
IN-LINE
SPLICE
3 PHASE 3 WIRE FIELD CONNECTION
L1 L2 L3
1 3 5 7 9 11
2 4 6 8 10 12

CHAPTER 7: PARTS LIST
7.1 Accessories
ITEM PART # COMPONENT 1 810-2112 Basket Hanger, Wire Form 2 809-0171 Basket Hanger Screw 3 803-0155 Holder, Portion Cup 4 803-0018 Cup, Portion 5 823-1662 Basket, Bulk Product 6 803-0167 Rack, Basket Support 7 910-2545 Strainer 8 806-3811 Legs, Package of 4 Adjustable 9 810-0357 Caster w/Brake 10 810-0356 Caster w/o Brake * 826-1113 Kit, Leg/Caster Mounting (1 kit required per leg or caster) 11 826-1095 Kit, Anchor Strap (for use w/Cookers equipped with legs) 12 826-0900 Kit, Chain Restraint (for use w/Cookers equipped with casters) 13 803-0234 Brush, Probe Cleaning * 823-2608 Connecting Strip, 8SMS * Not illustrated

7.2 Basket Lift Components
16 17 18 19 20 21 22 23
1 2 3 4 5 6 7 8 9 10 11

ITEM PART # COMPONENT 1 809-0127 Screw, ¼-20 x ½-inch Round Head 2 810-0192 Rod, Basket Lift 3 823-1840 Arm, Basket Lift 4 900-7226 Enclosure, Basket Lift 5 809-0050 Nut, 8-32 Hex Head 6 Motor, Basket Lift 807-0107 120 VAC 807-0108 240VAC 7 920-3095 Mount, Basket Lift Motor 8 809-0049 Nut, 6-32 Hex Head 9 812-0138 Insulation, Paper 10 807-0240 Microswitch, BA-2RV22-D6 11 807-0124 Bushing, Plastic 12 809-0194 Washer, 5/16-inch SAE Flat 13 810-0220 Spacer, Tubular 14 809-0203 Washer, ½-inch Nylatron 15 809-0155 Screw, Leveling 16 809-0063 Nut, ⅜-inch Jam 17 809-0196 Washer, ⅜-inch SAE Flat 18 810-0052 Bellcrank * 809-0480 Setscrew, ¼-28 x ⅝-inch (secures Bellcrank to motor shaft) 19 809-0097 Screw, 6-32 x 1-inch Slotted Truss Head 20 809-0113 Screw, 8-32 x 1½-inch Slotted Truss Head 21 810-0172 Button, Plug 22 809-0076 Nut, ¼-20 Expansion 23 809-0134 Screw, ¼-20 x 1½-inch Round Head 24 920-3190 Link, Basket Lift 25 810-0170 Pin, ¼-inch x ⅝-inch Spring Dowel 26 813-0035 Bushing, Bronze * 809-0082 Ring, Retaining (secures bronze bushing 813-0035 in place) 27 900-4266 Angle, Bushing Support * Not illustrated

7.3 Cabinetry


ITEM PART # COMPONENT 1 806-9744SP Door Assembly (does not include handles) 2a 810-1402 Handle, Wireform Door (cannot replace 210-9214) 2b 210-9214 Handle, Eurolook Door (cannot replace 810-1402) * 809-0266 Screw, Door Handle * 810-1508 Hinge Bracket, Door * 806-4487SP Pin Assembly, Door * 826-1343 Spring, Door Pin 3 806-4735SP Frame Assembly, 8SMS Control Panel * 910-4308 Blank Control Panel (used on rinse tank side of 8SMS) 4 910-7205 Top Cap, 8SMS 5 823-2609 Flue Cap, 8SMS 6 910-0207 Plate, Faucet Mounting (all models) 7 900-7202SP Divider, 8SMS Cabinet 8 810-1105 Magnet, Door 9 900-7198 Post, 8SMS Door 10 900-4334 Shield, 8SMS Basket Lift Motor 11 Side, Right (all models) 902-7167SP Painted Steel 912-7167SP Stainless Steel 12 Side, Left (all models) 901-7167SP Painted Steel 911-7167SP Stainless Steel 13 900-7201SP Panel, 8SMS Cabinet Back 14 900-4766 Panel, Basket Lift Upper Access (all models) 15 900-4351 Panel, Basket Lift Lower Access (all models) * 900-7199SP Brace, 8SMS Cabinet Top * 900-1536 Bracket, Top Half Pot Hold Down (all models) * 900-1537 Bracket, Top Half Pot Hold Down (all models) 16 806-5067SP Guide Assembly, Basket Lift (all models) 16a 809-0047 Nut, Cap 16b 810-0194 Roller 16c 810-0374 Spacer 16d 809-0508 Bolt, ¼-20 x 1¼-inch 16e 823-1803 Bracket 17 900-7156SP Channel, Base Side (all models) 18 900-7200SP Channel, 8SMS Base Front and Rear * 806-5209SP Pad Assembly, Leg or Caster Mounting (all models) 19 823-1714 Flue Cap, 8BC/8C 20 910-1514 Top Cap, 8BC/8C 21 806-4725SP Frame, 8BC/8C Control Panel 22 900-7155SP Panel, 8BC/8C Cabinet Back 23 900-7277 Stiffener, Cabinet Side (all models) 24 900-4279SP Brace, 8BC/8C Cabinet Top 25 900-4280SP Channel, 8BC/8C Base Front and Rear 26 900-7848 Shield, 8BC/8C Vapor * Not illustrated

7.4 Cookpot and Rinse Tank Components

1 2 3 4 5 6 7 8 9 10

ITEM PART # COMPONENT 1 810-0698 Cookpot, 8SMS/8BC/8C 2 810-1697 Block, Probe * 826-1081 Kit, Probe Block (old style with pins and cover) * 823-2791 Cover, Probe Block * 823-1942 Cover, Probe (old style with holes for pins) 3 823-1920 Sensor, Lower Water Level (approximately 7 inches long) 4 823-1921 Sensor, Upper Water Level (approximately 4¼ inches long) * 809-0193 Washer, ¼-inch Nylon (used on water level sensors) * 807-0037 Tab, Push-on Male (used on water level sensors) 5 810-0713 Nozzle, Spray 6 910-1804 Bracket, Temperature Probe Retaining * 809-0357 Screw, #6 x ⅜-inch (used to secure sensors and probe bracket in place) 7 806-4764 Temperature Probe (with connectors) 8 816-0113 Gasket, Overflow Drain 9 900-1537 Bracket, Pot Hold Down Bottom 10 809-0256 Nut, 10-32 Keps Hex 11 823-1711 Drain, Overflow 12 900-5675 Bracket, High-Limit Thermostat Mounting 13 826-1601 Thermostat, High-Limit (includes high-limit, gasket, and tie wrap) * 809-0567 Tie Wrap, Metal (secures Hi-Limit Thermostat to Element) 14 810-1826 Handle, Drain Valve 15 814-0047 Sleeve, Red Valve Handle (with logo) 16 813-0395 Union, 1¼-inch NPT 17 813-0070 Elbow, 1¼-inch x 90º NPT 18 813-0394 Tee, 1¼-inch NPT 19 813-0391 Nipple, 1¼-inch NPT Close 20 810-1825 Valve, 1¼-inch NPT Drain 21 813-0397 Reducer, 1½-inch Sink to 1¼-inch NPT 22 816-0221 Washer, 1¾-inch Sink 23 809-0464 Nut, 1½-inch Conduit 24 809-0465 Washer, Sink Drain 25 813-0396 Drain, 1½-inch Sink (includes item 23) 26 809-0204 Washer, ⅝-inch Flat 27 809-0444 Nut, Hex Jam 28 813-0302 Elbow, ¼-inch NPT to ⅜-inch Tube 90º Compression 29 823-1657 Fascia, Overflow Drain 30 809-0360 Screw, #8 x ⅜-inch Hex Washer Head 31 810-0699 Tank, Rinse 32 809-0270 Screw, 10-32 x ½-inch Truss Head 33 809-0192 Washer, ¼-inch Lock with external teeth 34 Element, 8kW, 1- or 3-Ø (includes mounting washer and nut and standoff) 826-1795 208VAC 826-1797 230VAC 826-1798 240VAC 807-1729 480VAC (requires two teflon washers, 809-0204) * Not illustrated

7.5 Electrical Components and Controllers
12 13 14 15 12 16 17
ITEM PART # COMPONENT 1 807-1396 Relay, 24VDC 2 807-1308 Holder, Fuse 3 807-1555 Fuse, 5 Amp 4 809-0362 Screw, #8 x 1¼-inch Hex Head 5 807-0878 Block, Terminal 6 807-0263 Terminal, Split 7 807-0680 Transformer, 208/240VAC – 24VAC 8 807-0070 Terminal, Ground Lug 9 806-4770 Valve Assembly, Solenoid 10 807-0875 Connector, 15-pin Female 11 810-1202 Contactor, 40 Amp 3 Pole 12 809-0361 Screw, #8 x ½-inch Hex Head 13 807-1292 Fitting, Plastic Conduit 14 812-0994 Conduit, ½-inch Plastic (17 inches long) 15 812-0992 Conduit, ½-inch Plastic (15 inches long) 16 900-7853 Cover, Component Box 17 823-1820 Box, Component 18 810-0044 Button, ⅞-inch Plug 19 809-0454 Nut, ½-inch Conduit 20 809-0096 Screw, 6-32 x ⅝-inch 21 809-0250 Nut, 6-32 Keps * 806-5332 Cordset, Basket Lift (used with 480/120VAC dual-voltage units only) * WIR0013SP Wire Assembly, 8SMS Contactor Box * 806-4702 Cable, 8SMS Controller * Controller, 8SMS 106-0371 CE and non-CE with AutoFill and AutoSkim 106-0373 CE and Non-CE with AutoFill but without AutoSkim 106-0374 CE and Non-CE without Autofill or Autoskim * Not illustrated.

7.6 Water Supply Components
ITEM PART # COMPONENT 1 806-4770 Solenoid Assembly, Autofill 2 810-1208 Regulator, Water Pressure 3 813-0412 Faucet, Double Jointed * 826-1132 Kit, Faucet Repair (contains two valve assemblies) 4 900-2114 Tube, Copper Water Supply 5 910-2496 Tube, Stainless Steel Autofill 6 813-0302 Elbow, Brass ⅜-inch Tube to ¼-inch NPT (w/Compression Nut) 7 813-0448 Elbow, Brass ¼-inch x 90º NPT 8 813-0473 Nipple, Brass ¼-inch x 4-inch NPT 9 813-0449 Tee, Brass, ¼-inch NPT 10 813-0471 Nipple, Brass ¼-inch x 1.5-inch NPT 11 809-0444 Nut, ¾-10 Hex Head Jam 12 816-0114 Gasket, Spray Nozzle 13 810-0713 Nozzle, Spray * 826-1135 Kit, Non-Autofill to Autofill Conversion * Not illustrated






TEL 1-318-865-1711 FAX (Parts) 1-318-219-7140 (Tech Support) 1-318-219-7135
FEB 11
1-800-551-8633 819-5246
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.