EN
Emerson logo
Official user manual

Emerson TYPE SS

2 pages·383 KB·Surge Protector·PDF·ENDEFRITNLJA
Emerson TYPE SS
Table of Contents 13 sections Approved by Motorola R56 2005 Version, Standards and · Guidelines for Communication Sites — Type 1, Type 2 Devices · Two Different Units Available: · Typical Applications: · … ShowHide
Page 1 of the Emerson TYPE SS user manual — Typical Applications:
Page 1 · click to enlarge
Page 1
Emerson TYPE SS — Approved by Motorola R56 2005 Version, Standards and diagram (page 1)
Fig. 1 · Approved by Motorola R56 2005 Version, Standards and

Liebert TYPE SS Transient Voltage Surge Suppression Advanced Hybrid Surge Suppression Technology

Emerson TYPE SS — Liebert TYPE SS Transient Voltage Surge Suppression Advanced Hybrid Surge Suppression Technology diagram (page 1)
Fig. 2 · Liebert TYPE SS Transient Voltage Surge Suppression…

Approved by Motorola R56 2005 Version, Standards and

Guidelines for Communication Sites — Type 1, Type 2 Devices

Utilizes advanced SAD/MOV array technology for industry leading transient suppression voltages

Incorporates Liebert’s “state-of-the-art” Interceptor technology for enhanced safety and performance coordination of all surge and fuse components

Modular design for flexibility and ease of servicing 160 kA surge current capacity for increased reliability Real-time system monitoring Product performance and safety standards — UL1283, UL 1449 Second Edition 2005, (effective Feb. 9, 2007), C22.2 No. 8 Bulletin 516 and NEMA LS1-1992

Two Different Units Available:

Type 1 Hybrid TVSS — 20 kA of SAD protection and 160 kA of MOV protection Type 2 MOV only TVSS — 160 kA of MOV protection

WarrantyCovered 24x7 by Emerson Network Power Service Business: 10-Years for Parts, 5-Years On-Site Labor

Typical Applications:

Emerson TYPE SS — Typical Applications: diagram (page 1)
Fig. 3 · Typical Applications:

Cell Sites Communication shelters AC main and distribution panels and load centers Transmitters Base Stations

Page 2 of the Emerson TYPE SS user manual — Emerson Network Power.com
Page 2 · click to enlarge
Page 2
Emerson TYPE SS — Liebert TYPE SS Transient Voltage Surge Suppression diagram (page 2)
Fig. 4 · Liebert TYPE SS Transient Voltage Surge Suppression

Liebert TYPE SS Transient Voltage Surge Suppression

Liebert Corporation

1050 Dearborn Drive P.O. Box 29186 Columbus, Ohio 43229 800 877 9222 Phone (U.S. & Canada Only) 614 888 0246 Phone (Outside U.S.) 614 841 6022 FAX

MOV/SAD Current Sharing – Type 1 Model

100.0 90.0 80.0 70.0 60.0 50.0 40.0 30.0 20.0 10.0 0.0 0 5000 10000 15000 20000 25000 30000

The Liebert Answer:

Emerson TYPE SS — MOV/SAD Current Sharing – Type 1 Model diagram (page 2)
Fig. 5 · MOV/SAD Current Sharing – Type 1 Model

The Liebert TYPE SS Type I Model offers a true, coordinated multi-stage system of suppression. It integrates the fast response time of the silicon avalanche diode (SAD) with the high- energy capability of the metal oxide varistor (MOV) for increased reliability and performance. This unique circuitry does not sacrifice the sensitive SAD module when subjected to a damaging high-energy transient event.

Surge Current (%)

Via Leonardo Da Vinci 8 Zona Industriale Tognana 35028 Piove Di Sacco (PD) Italy 39 049 9719 111 Phone 39 049 5841 257 FAX

8/20 µ s Surge Current (Amperes)

Emerson Network Power Asia Pacific 7/F., Dah Sing Financial Centre 108 Gloucester Rd, Wanchai Hong Kong 852 25722201 Phone 852 28029250 FAX

Technical Specifications

Voltage Configurations 120/240V and 120/208V (Please consult factory for additional voltage configurations)

Maximum Continuous ≥125% Operating Voltage (MCOV)

liebert.com

Fault Current Rating (AIC) 200 kAIC

Operating Frequency Range 47 – 63 Hz

Technical Support 800 288 6169 Toll-Free 607 724 2484 Phone 607 722 8713 Fax

Connection Parallel (4-6 AWG recommended and 14-1/0 AWG capable); wire lug or disconnect

Modes of Protection Line to Neutral/standard

Surge Current Capacity 160 kA per mode

Response Time

While every precaution has been taken to ensure accuracy and completeness in this literature, Liebert Corporation assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions.

Dimensions 15.32 in. x 13.32 in. x 6.60 in.

Weight 35 lbs.

© 2007 Liebert Corporation. All rights reserved throughout the world. Specifications subject to change without notice.

Operating Temperature -40°C to +60°C

All names referred to are trademarks or registered trademarks of their respective owners.

Status Indication LEDs, Form “C” contacts — 2 sets

® Liebert and the Liebert logo are registered trademarks of the Liebert Corporation.

Form “C” Contact Rating 120 VAC, 5.0 amps, pF of 1.0

Certifications Product performance and safety standards — UL 1283, UL 1449 Second Edition 2005, (effective Feb. 9, 2007), C22.2 No.8 Bulletin 516, NEMA LS1-1992

SL-22090 (R05/07) Printed in USA

Emerson Network Power. The global leader in enabling Business-Critical Continuity™.

Technology Type 1 Hybrid TVSS — 20 kA of SAD protection and 160 kA of MOV protection

Type 2 MOV only TVSS — 160 kA of MOV protection

Enclosure NEMA 4X; suitable for indoor or outdoor applications

AC Power Connectivity DC Power Embedded Computing Embedded Power Monitoring Outside Plant Power Switching & Controls Precision Cooling Racks & Integrated Cabinets Services Surge Protection

Warranty Covered 24x7 by Emerson Network Power Service Business 10-Years Parts and 5-Years On-Site Labor

Typical NEMA LS1 Data

Emerson TYPE SS — Typical NEMA LS1 Data diagram (page 2)
Fig. 6 · Typical NEMA LS1 Data

Type 1 Unit; Type 2 Unit; Line - Neutral Line - Neutral

Category A Ringwave 176 284 (6 kV / 0.2 kA)

Category B Ringwave 288 304 (6 kV / 0.5 kA)

UL 1449 Combination Wave 256 300 (6 kV / 0.5 kA)

Category B Combination 304 336 Wave (6 kV / 3.0 kA)

Emerson Network Power.com

Category C Combination 440 408 Wave (20 kV / 10.0 kA)

Business-Critical Continuity™, Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2007 Emerson Electric Co.

Ask about the Emerson TYPE SS

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Emerson TYPE SS

Be the first to ask — other owners or our team will answer.

Original document

Emerson TYPE SS manual PDF

2 pages·383 KB·Surge Protector·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…