Emerson Active Tracking

4 pages·1.1 MB·Surge Protector·PDF·ENDEFRITNLJA
Emerson Active Tracking
Table of Contents 41 sections ® Filter Series The Ultimate Solution To Power Disturbance Problems · In today's world, almost every business depends on · Features That Make The Difference · sensitive microprocessor-based electronics to conduct · … ShowHide
® Filter Series The Ultimate Solution To Power Disturbance Problemsp.1In today's world, almost every business depends onp.2Features That Make The Differencep.2sensitive microprocessor-based electronics to conductp.2The Industry's Best Attenuation Of Voltagep.2their day to day operations. This means that electricp.2power line disturbances can disrupt or cripple equipmentp.2The Industry's Best Attenuation Of 100 kHz Ringwavesp.2Liebert understands this problem and offers a way top.2keep these power problems from getting into yourp.2Stringent, Independent Testing For Performancep.2I ANSI/IEEE C62.11, C62.41, C62.45 Categories A, B,p.2I Independently tested surge current ratings from 100kAmpsp.2I Life cycle tested: will survive in excess of 12,000 10kAmpp.2Engineered For Superior Surge Current Ratings And Long Lifep.2I Unique sand-packed silver fuse network allows rated surgep.2I Unprecedented redundancy offers expanded mean-time-p.2Proven Performancep.2Compatible With All Linear Loadsp.2Modular Design For Ease Of Customization And Servicep.2I Enables you to specify an Interceptor system to match thep.2Sophisticated User-Friendly Diagnosticsp.2I On-line system monitoring/testing for all suppressionp.2I Standard features include: audible alarm, transientp.2I Optional features include: additional seven-digit transientp.2Manufactured To The Most Stringent ISO Quality Standardsp.2A Dedicated Service Network Protects You Toop.2I Dedicated service network with over 400 Liebert-trainedp.2Specificationsp.3Chart A - Active Tracking ® Filter Systemsp.3Chart B - Nominal Voltage Codesp.3F120Y30-03p.3Emerson Network Power, the global leader in enabling business-criticalp.4Liebert Corporationp.4continuity, ensures network resiliency and adaptability through a familyp.4of technologies — including Liebert power and cooling technologies —p.4that protect and support business-critical systems. Liebert solutions employp.4an adaptive architecture that responds to changes in criticality, density andp.4capacity. Enterprises benefit from greater IT system availability, operationalp.4liebert.comp.4Technical Supportp.4
Page 1 of the Emerson Active Tracking user manual — ® Filter Series The Ultimate Solution To Power Disturbance Problems
Page 1 · click to enlarge
Page 1
Emerson Active Tracking — ® Filter Series The Ultimate Solution To Power Disturbance Problems diagram (page 1)
Fig. 1 · ® Filter Series The Ultimate Solution To Power Distu…

® Filter Series The Ultimate Solution To Power Disturbance Problems

® ebert
Page 2 of the Emerson Active Tracking user manual — A Dedicated Service Network Protects You Too
Page 2 · click to enlarge
Page 2
Emerson Active Tracking — In today's world, almost every business depends on diagram (page 2)
Fig. 2 · In today's world, almost every business depends on

In today's world, almost every business depends on

Features That Make The Difference

sensitive microprocessor-based electronics to conduct

The Industry's Best Attenuation Of Voltage

Transients Proprietary Active Tracking sinewave correction filter continuously provides close voltage control at any location on the sinewave.

their day to day operations. This means that electric

power line disturbances can disrupt or cripple equipment

causing a major loss in productivity — and money.

The Industry's Best Attenuation Of 100 kHz Ringwaves

The Active Tracking filter system minimizes the aftershocks of voltage transients and the inherent energy storage system smoothes the sinewave by filling notches and reducing spikes.

Liebert understands this problem and offers a way to

keep these power problems from getting into your

Stringent, Independent Testing For Performance

facility in the first place.

I UL 1449, UL 1283 and CSA Listed.

I ANSI/IEEE C62.11, C62.41, C62.45 Categories A, B,

The answer is the Liebert Interceptor® Series Active Tracking® Filter. These series-connected systems provide the highest level of protection with the lowest UL 1449 clamping ratings available.

and C3 tested.

I Independently tested surge current ratings from 100kAmps

to 300kAmps.

I Life cycle tested: will survive in excess of 12,000 10kAmp

surges per IEEE Category C3.

By closely controlling voltage at every location along the sinewave, our Active Tracking filter technology protects sensitive electronic equipment from the potentially damaging effects of low-energy voltage transients and the ringwaves that follow. The filter also stores and releases energy to fill and reduce sinewave spikes and notches.

Engineered For Superior Surge Current Ratings And Long Life

I Computerized "smart" array technology for surge protection.

I Unique sand-packed silver fuse network allows rated surge

current to pass through without fuse operation.

I Unprecedented redundancy offers expanded mean-time-

between-failure (MTBF).

I Sinewave tracking EMI/RFI filtering.

I Fast response time — less than .5 nanoseconds.

I All modes of protection.

Proven Performance

High-energy current diversion is handled by the Interceptor's sophisticated parallel system of computer- matched MOV (metal-oxide varistor) arrays. Each array module is sand-encapsulated and screened to provide exact current sharing and prevent component degradation. Our patented, coordinated fusing is UL Listed for 200kAIC at 600VAC to ensure absolute safety, yet allow surge current capability to be attenuated.

Compatible With All Linear Loads

I Provides flexibility for a wide range of applications.

Modular Design For Ease Of Customization And Service

I Enables you to specify an Interceptor system to match the

needs of a specific application. Also allows easy replacement of surge modules if required.

Sophisticated User-Friendly Diagnostics

I On-line system monitoring/testing for all suppression

The Interceptor Series Active Tracking Filter is UL 1449, UL 1283 and CSA Listed. Our manufacturing facility is ISO 9001 Registered. Surge current ratings are independently tested, so you can specify a Liebert product with complete confidence. And we back every Liebert Interceptor Series filter with the industry's only five-year warranty for on-site labor.

components in all modes of protection.

I Standard features include: audible alarm, transient

counter, door LEDs indicating unit status, individual module status LEDs, and Form C dry contacts for remote system integrity monitoring and indication of undervoltage, phase and/or power loss.

I Optional features include: additional seven-digit transient

counter for normal mode, additional Form C dry contacts.

Manufactured To The Most Stringent ISO Quality Standards

I ISO 9001 registration for design, manufacturing and service.

A Dedicated Service Network Protects You Too

I Dedicated service network with over 400 Liebert-trained

and authorized technicians.

I Toll-free service hotline manned 24 x 7.

Page 3 of the Emerson Active Tracking user manual — F120Y30-03
Page 3 · click to enlarge
Page 3

Specifications

- Optional Features 2.0” MAX - Standard Features .50” MAX Line Frequency 47 to 63 Hz Line Voltage ±15% nominal Temperature -40 to +60°C Operating Humidity 0 to 95% noncondensing Altitude 0 to 18,000 feet Audible Noise Less than 45 dBa Operational Crest Factor 3.0 Warranty 10-Years Parts and 5-Years On-Site Labor

Emerson Active Tracking — Specifications diagram (page 3)
Fig. 3 · Specifications

Connection Type Series connected Agency Listings UL 1449, UL 1283, CSA Protection Modes All modes standard (Line to Neutral, Line to Ground, Neutral to Ground, Line to Line); any combination optional EMI/RFI Filtering Normal mode — 60 dB maximum from 10 kHz to 500 MHz; Common mode 50 dB maximum from 10 kHz to 500 MHz Response Time less than .5 nanoseconds Load Regulation 1% no load to full load Enclosure NEMA 12 standard; options include NEMA 3R, 4, 4X and caseless for switchgear applications

How To Specify The Appropriate Model: 1) Go to Chart A, choose your Current Rating from column one and corresponding Configuration from column two. 2) Follow column two across to column three to determine your Model Number. 3) Refer to Chart B to determine the Voltage Code from the available choices. Substitute the Voltage Code for “XXX.” (Use the first three digits of the Voltage Code for split phase and three phase configurations). 4) Finally, to complete your model number, go to the last column or (Monitoring Options) and choose the suffix for Standard Features (-06) or Optional Features (-03).

Chart A - Active Tracking ® Filter Systems

Current RatingConfigurationModel Number (xxx=voltage code)Surge Current Capability per phase (L-N or L-L+L-G)Dimensions (inches)WeighMonitoring t Options ABCDEFLbs.Standard Features Include: 30ASingle Phase L-LFXXXL30100kA24.020.09.021.2510.0.4440•Audible Alarm, Transient Counter • Door LEDs indicating unit status • Individual Module Status LEDs, and -06 Form C Dry Contacts for Remote System Integrity Monitoring and Indication of Under Voltage, Phase and/or Power Loss. 30ASingle Phase L-NFXXXN30100kA24.020.09.021.2510.0.4435 30ASplit PhaseFXXXS30100kA24.020.09.025.2514.0.4445 30AThree Phase DeltaFXXXD30100kA24.020.09.025.2514.0.4450 30AThree Phase WyeFXXXY30100kA24.020.09.025.2514.0.4460 60ASingle Phase L-LFXXXL60100kA24.020.09.021.2510.0.4440 60ASingle Phase L-NFXXXN60100kA24.020.09.021.2510.0.4435 60ASplit PhaseFXXXS60100kA24.020.09.025.2514.0.4445 60AThree Phase DeltaFXXXD60100kA24.020.09.025.2514.0.4450 60AThree Phase WyeFXXXY60100kA24.020.09.025.2514.0.4460 100ASingle Phase L-LFXXXL100150kA30.024.09.031.2518.0.4465Optional Features Include: 100ASingle Phase L-NFXXXN100150kA30.024.09.031.2518.0.4460• Additional SevenDigit Transient Counter for Normal Mode -03 • Additional Form C Dry Contacts 100ASplit PhaseFXXXS100150kA30.024.09.031.2518.0.4470 100AThree Phase DeltaFXXXD100150kA30.024.09.031.2518.0.4470 100AThree Phase WyeFXXXY100150kA30.024.09.031.2518.0.4480 125ASingle Phase L-LFXXXL225150kA30.024.09.031.2518.0.4465NOTES: For configurations not mentioned, including caseless units for switchgear applications and ungrounded delta units, consult factory. For different levels of surge current capacity mode and/or phase, consult factory. CODE: L - N = Line to Neutral L - G = Line to Ground N - G = Neutral to Ground L - L = Line to Line *Valid for 220/380 and 240/415 per IEC. 125ASingle Phase L-NFXXXN225150kA30.024.09.031.2518.0.4460 225ASplit PhaseFXXXS225150kA30.024.09.031.2518.0.4470 225AThree Phase DeltaFXXXD225150kA30.024.09.031.2518.0.4470 225AThree Phase WyeFXXXY225150kA30.024.09.031.2518.0.4480 400AThree Phase DeltaFXXXD400150kA48.036.012.049.2530.0.44275 400AThree Phase WyeFXXXY400150kA48.036.012.049.2530.0.44300 800AThree Phase DeltaFXXXD800choose 200 or 300 kA60.048.012.0---500 800AThree Phase WyeFXXXY800choose 200 or 300 kA60.048.012.0---530 1200AThree Phase DeltaFXXXD1200choose 200 or 300 kA60.048.020.0---700 1200AThree Phase WyeFXXXY1200choose 200 or 300 kA60.048.020.0---750 2000AThree Phase DeltaFXXXD2000choose 200 or 300 kA60.048.020.0---875 2000AThree Phase WyeFXXXY2000choose 200 or 300 kA60.048.020.0---950 4000AThree Phase DeltaFXXXD4000choose 200 or 300 kA60.048.020.0---1175 4000AThree Phase WyeFXXXY4000choose 200 or 300 kA60.048.020.0---1300

Chart B - Nominal Voltage Codes

Example Model Number:

F120Y30-03

(substitute for “xxx” to complete model number)

Single Phase, 2 wire plus ground 100, 110, 120, 230, 240, 277, 346, 400, 480, 600

Split Single Phase, 3 wire plus ground 100/173, 110/190, 120/208 or 240, 230/400, 277/480, 346/600

Three Phase Delta, 3 wire plus ground 208, 240, 380, 400, 480, 600

Three Phase Delta Hi-Leg, 4 wire plus ground 120/240

Three Phase Wye, 3 or 4 wire plus ground 100/173, 110/190, 120/208, 230/400, *277/480, 346/600

Page 4 of the Emerson Active Tracking user manual — liebert.com
Page 4 · click to enlarge
Page 4

Ensuring The High Availability Of Mission-Critical Data And Applications.

Emerson Network Power, the global leader in enabling business-critical

Liebert Corporation

continuity, ensures network resiliency and adaptability through a family

1050 Dearborn Drive P.O. Box 29186 Columbus, Ohio 43229 800 877 9222 Phone (U.S. & Canada Only) 614 888 0246 Phone (Outside U.S.) 614 841 6022 FAX

of technologies — including Liebert power and cooling technologies —

that protect and support business-critical systems. Liebert solutions employ

an adaptive architecture that responds to changes in criticality, density and

capacity. Enterprises benefit from greater IT system availability, operational

Via Leonardo Da Vinci 8 Zona Industriale Tognana 35028 Piove Di Sacco (PD) Italy 39 049 9719 111 Phone 39 049 5841 257 FAX

flexibility, and reduced capital equipment and operating costs.

Emerson Network Power Asia Pacific 7/F., Dah Sing Financial Centre 108 Gloucester Rd, Wanchai Hong Kong 852 25722201 Phone 852 28029250 FAX

liebert.com

Technical Support

607 724 2484 Phone 800 288 6169 Toll-Free 607 722 8713 Fax

While every precaution has been taken to ensure accuracy and completeness in this literature, Liebert Corporation assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions.

© 2005 Liebert Corporation. All rights reserved throughout the world. Specifications subject to change without notice.

All names referred to are trademarks or registered trademarks of their respective owners.

® Liebert and the Liebert logo are registered trademarks of the Liebert Corporation.

SL-22006 (R9/05) Printed in USA

derinenablin Systems ity Systems
criticalcontinuit Power
EmersonNetwo
Cabinet Solutio
Monitoring

Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2005 Emerson Electric Co.

Ask about the Emerson Active Tracking

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Emerson Active Tracking

Be the first to ask — other owners or our team will answer.

Original document

Emerson Active Tracking manual PDF

4 pages·1.1 MB·Surge Protector·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…