Wash hands after handling.


The heater is designed and approved for use as a construction heater under ansi z83.7a, csa 2.14a. it is hard to anticipate every use which may be made of this heater. CHECK WITH YOUR LOCAL FIRE SAFETY AUTHORITY IF YOU HAVE QUESTIONS ABOUT APPLICATIONS.
other standards govern the use of fuel gases and heat producing products in specific applications. your local authority can advise you about these.
This is a direct-fired cabinet construction heater for indoor construction. The heater must be placed where it is not directly exposed to water spray, rain, and/or dripping water. its intended use is primarily the temporary heating of buildings or structures under construction, alteration or repair. all the products of combustion generated by the heater are released into the area being heated. This heater operates at approximately 99% combustion efficiency but still produces a small amount of carbon monoxide. humans can tolerate small amounts of carbon monoxide for short periods. carbon monoxide can build up in a heated space and failure to provide adequate ventilation could result in poisoning or death.
OR WHILE CONNECTED TO A FUEL SOURCE.
fiRe, BuRn, inhalaTion, and explosion hazaRd. Keep solid comBusTiBles, such as Building maTeRials, papeR oR caRdBoaRd, a safe disTance away fRom The heaTeR as Recommended By These insTRucTions. neveR use The heaTeR in spaces which do oR may conTain volaTile oR aiRBoRne comBusTiBles, oR pRoducTs such as gasoline, solvenTs, painT ThinneRs, dusT paRTicles oR unKnown chemicals.
This is an unvenTed poRTaBle heaTeR. iT uses aiR (oxygen) fRom The aRea which iT is used. ample comBusTion and venTilaTion aiR musT Be pRovided. CAUTION
if The infoRmaTion in This manual is noT followed exacTly, a fiRe oR explosion may ResulT causing pRopeRTy damage, peRsonal injuRy oR loss of life. WARNING
a do noT sToRe oR use gasoline oR oTheR flammaBle vapoRs and liQuids in The viciniTy of This oR any oTheR appliance. a an lp cylindeR noT connecTed foR use shall noT Be sToRed in The viciniTy of This oR any oTheR appliance.

accidents are always tragic especially because so many of them could have been prevented with little care and judgment. There are some basic good practices, we hope you will follow for safe use of your heater.



1. Remove heater from carton. 2. Remove all protective packaging applied to heater for shipment. 3. Retain carton and packing material until you confirm the unit operates and is found in good condition. 4. check heater for any shipping damage. if heater shows any external or internal damage, promptly inform dealer/distributor where you purchased heater. 5. Remove back cover. 6. locate the four (4) casters shipped with the unit. There are two (2) locking casters and two non-locking casters. also find the four (4) washers and wrench shipped with the casters. 7. carefully lay the unit on its back. 8. place one washer on each of the threaded portions of the caster. (see figure 1). 9. Thread the casters into the four threaded holes in the base of the unit by turning them clockwise . The locking casters should be placed at the front of the unit and the other two at the back of the unit. (see figure 1). 10. Tighten The casters using the wrench supplied with the casters. 11. install 20 lb propane cylinder. (see propane supply section) 12. install back cover by inserting the mounting tabs into the slots on the rear flange of the heater. CAUTION: The casters must be installed onto the unit before it is used. failure to install the casters may result in a fire or explosion causing property damage, personal injury or loss of life.
wRench included wiTh casTeRs
washeR · locKing casTeRs · non-locKing casTeRs

you must provide the propane gas and cylinder(s). use this heater only with a propane vapor withdrawal supply system. Refer to chapter 5 of the standard for storage and handling of liquefied petroleum gas, ansi/nfpa 58. your local library or fire department will have this booklet.
a shutoff valve terminating the cylinder valve outlet as specified in the american national standard for
compressed gas cylinder valve outlet and inlet connections, and a safety relief valve in direct contact
with the vapor space of the tank.
regulator connected, as this can cause damage to the regulator diaphragm.
there is excessive abrasion or wear, or the hose is cut, it must be replaced prior to the heater being
put into operation. The replacement hose assembly shall be that specified by the manufacturer.

UNPACKING THE HEATER
IMPORTANT!
always use a pRopane (lp) cylindeR ThaT has a connecTion device ThaT is compaTiBle wiTh The hose and RegulaToR assemBly supplied.
THE PROPANE (LP) GAS PRESSURE REGULATOR AND HOSE ASSEMBLY SUPPLIED WITH THE HEATER MUST BE USED WITHOUT ALTERATION. BE SURE TO INSPECT THE REGULATOR HOSE BEFORE EACH USE. IF THE HOSE IS CUT OR FRAYED, REPLACE IT WITH THE MANUFACTURER SUGGESTED ASSEMBLY.
1. provide propane/lp supply system (see propane supply, page 7). 2. insert the 20 lb propane cylinder into the rear of the heater and position it such that the outlet of the cylinder valve is facing towards the front-left corner of the unit. see figure 2. 3. connect the fitting of the hose/regulator assembly to the cylinder outlet. Turn the fitting counterclockwise into the threads of the cylinder valve. some models have a hand wheel that can be slid off the nut so that a wrench can be used to tighten the fitting, if desired.
position the regulator such that the side with the tower is facing down and the flat side is facing up. see figure 2.
ensure that the gas hose is not touching the unpainted heat shield at the front of the cylinder enclosure. see figure 2.
4. open propane/lp supply valve on propane/lp tank(s) slowly. noTe: if not opened slowly, excess flow device in regulator may stop gas flow. if this happens, close propane/lp supply valve, wait one minute (or until you hear a click) and open again slowly. 5. check all connections for leaks. apply a 50/50 solution of liquid dish soap and water to gas joints. Bubbles forming show a leak that must be corrected. 6. close propane / lp supply valve before attempting to repair connection.

GARAGE OR ANY OTHER ENCLOSED AREA.
puRging and filling of lp gas TanKs musT Be peRfoRmed By peRsonnel who have Been ThoRoughly TRained in accepTed lp gas indusTRy pRoceduRes. failuRe To follow These insTRucTions may ResulT in explosion, fiRe, seveRe peRsonal injuRy, oR deaTh.

do not force.
follow the leak checking section in the manual. if you do not smell gas, go to next step.
and depress for 5 seconds. (B)
depressed for at least 30 seconds. This will allow air to bleed from the gas system.
piezo ignitor to light the pilot gas. Keep control knob depressed thirtry (30) seconds before releasing.
if the pilot does not light, depress the control knob and turn to the “off” position. Repeat steps 5 and 6.
or high . (c)
(C)

Turning burner only OFF (pilot stays lit). Turn control knob clockwise to “piloT” position. (B)
never store a propane gas tank inside a building or in the vicinity of any gas or oil burning appliance. when the propane tank is not disconnected from the construction heater, the gas tank and heater must be stored outdoors in a well ventilated area, out of the reach of children. if for any reason the heater is to be stored indoors, the tank must be disconnected and stored outdoors in a well ventilated area out of reach of children, in accordance with the standard for the the storage and handling of liquefied petroleum gases, ansi / nfpa 58 and csa B149.1, natural gas and propane installation code. The plastic tank valve plug supplied with your tank must be tightly installed when the tank is disconnected from the heater.
There is a brake in each of the front wheels of your heater that helps keep it in place when in use. To engage the brakes, push the lever down on each wheel. To move the heater, release the brakes, simply by flipping the levers on both brakes up.

Repair should be done by a qualified service person. The appliance should be inspected before use and at least annually by a professional service person. more frequent cleaning may be required due to excessive debris. it is imperative that control compartments, burners and circulating air passageways of the heater be kept clean. dust, lint, cobwebs or debris may affect heater performance. The heater draws air into it during normal operation and in the process dust, lint or debris may be drawn into it. Before cleaning ensure the gas supply is turned off at the cylinder and the gas control knob is in the “off” position.
each time you light the heater check that the pilot flame and burner flame patterns are as shown in fugures 4 and 5. if flame patterns are incorrect, turn the heater off and contact your dealer or qualified service person for assistance. do not operate the heater until the pilot and burner flames are correct. note: do not mistake orange flames with yellow tipping. dirt or dust particles may enter the burner flames and cause transient patches of orange flame.
figuRe 4 proper pilot flame
figuRe 5 correct Burner flame pattern


clean the exterior with soft bristle brush, vacuum cleaner or pressurized air. never use a wooden toothpick as it may break off and clog the ods pilot or main burner port. use a flashlight to inspect the main burner inlet to ensure it is not blocked. if obstruction can be seen, use a metal coat hanger that has been straightened out. use a vacuum cleaner to clean the primary air openings to the main burners.
use a vacuum cleaner or pressurized air to clean the combustion and circulating air passageways and a damp cloth to clean the cabinet/casing.
Thermocouple ignitor electrode · correct incorrect · correct incorrect

When ignitor is depressed there is no spark at ODS pilot.
When control knob is pressed in and turned counterclockwise to pilot and piezo is depressed, pilot does not light.
ODS pilot lights but flame goes out when control knob is released.
Burner does not light after ODS pilot is lit. 1. Burner orifice clogged. 2. Gas supply pressure is very low. 1. Clean burner orifice. 2. Contact gas supplier.
Delayed ignition. 1. Main burner carry over ports clogged. 2. Gas supply pressure is very low. 1. Clean main burner ports. 2. Contact gas supplier.
Burner backfiring during operation. 1. Burner orifice is clogged. 2. Burner ports damaged. 1. Clean burner orifice. 2. Replace burner.
Yellow flames during burner operation. 1. Not enough air. 1. Check air passageways and burner for dirt and debris. (Refer to Maintenance section)
Burner plaque(s) does not glow.
Slight smoke and odor during Initial operation. 1. Residues from manufacturing processes. 1. Will stop after a few hours of operation.
Heater produces a whistling noise when burner is lit.
Heater produces a clicking noise just after burner is lit or turned off. 1. Metal expanding and contracting. 1. This is common with heaters. If noise is excessive, contact a qualified, service technician.

Gas odor even when control knob is in OFF position.
Gas odor during combustion.
Heater shuts off on ODS.

LIMITED WARRANTY: This limited warranty is extended to the original retail purchaser of this Forced Air/Convection/Radiant Heater and warrants against any defect in materials and workmanship for a period of one (1) year from the date of retail sale. World Marketing of America, Inc., at it’s option, will either provide replacement parts or replace or repair the unit, when properly returned to the retailer where purchased or one of our service centers as directed by World Marketing, within one (1) year of retail purchase. (Shipping costs, labour costs, etc. are the responsibility of the purchaser.)
DUTIES OF THE OWNER: This heating appliance must be operated in accordance with the written instructions furnished with this heater. This warranty shall not excuse the owner from properly maintaining this heater in accordance with the written instructions furnished with this heater. A bill of sale, canceled check or payment record must be kept to verify purchase date and establish warranty period. Original carton should be kept in case of warranty return of unit.
WHAT IS NOT COVERED: 1. Damage resulting from use of improper fuel. 2. Damage caused by misuse or use contrary to the owners manual and safety guidelines. 3. Damage caused by a lack of normal maintenance. 4. Fuses 5. Use of non-standard parts or accessories. 6. Damage caused in transit. Freight charges on warranty parts or heaters to and from the factory shall be the responsibility of the owner.
This warranty does not imply or assume any responsibility for consequential damages that may result from the use, misuse, or the lack of routine maintenance of this heating appliance. A cleaning fee and the cost of parts may be charged for appliance failures resulting from lack of maintenance. This warranty does not cover claims which do not involve defective workmanship or materials. FAILURE TO PERFORM GENERAL MAINTENANCE (INCLUDING CLEANING) WILL VOID THIS WARRANTY.
THIS LIMITED WARRANTY IS GIVEN TO THE PURCHASER IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY OF FITNESS FOR A PARTICULAR PURPOSE. THE REMEDY PROVIDED IN THIS WARRANTY IS EXCLUSIVE AND IS GRANTED IN LIEU OF ALL OTHER REMEDIES. IN NO EVENT WILL WORLD MARKETING OF AMERICA BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES.
Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you.
CLAIMS HANDLED AS FOLLOWS: 1. Contact your retailer and explain the problem. 2. If the retailer is unable to resolve the problem, contact our Consumer Warranty Dept. detailing the heater model, the problem, and proof of date of purchase. 3. A representative will contact you. DO NOT RETURN THE HEATER TO WORLD MARKETING OF AMERICA, INC. unless instructed by our Representative. This warranty gives you specific legal rights and you may also have other rights which vary from state to state.
TO REGISTER THE WARRANTY ON YOUR HEATER, PLEASE FILL OUT THIS CARD COMPLETELY AND MAIL WITHIN 14 DAYS FROM DATE OF PURCHASE OR REGISTER ON-LINE AT www.worldmkting.com
NAME: PHONE: ( ) EMAIL: ADDRESS: CITY: STATE: ZIP: MODEL: SERIAL #: DATE PURCHASED: DEALER PURCHASED FROM: TYPE OF STORE: CITY & STATE WHERE PURCHASED: PRICE PAID:
Please Take a Minute To Give Us Your Answers To The Following Questions. All Responses Are Used Solely For Market Research And Are Held In Strict Confidence. Who primarily decided this purchase? Male Female 18-24 25-39 40-59 60 and over Purpose of Purchase? Do you own any other portable heaters? Yes No If yes, type brand How do you intend to use your new heater? Construction Site Farm Warehouse/Commercial Garage/Outbuilding Other How did you become aware of this heater? In-Store Display Newspaper Ad Magazine Ad Friend/Relative £TV Commercial £Store Salesperson Other What made you select this heater? Style Size/Portability Price Package Brand Other Do you: own rent Would you recommend this heater to a friend? Yes No Please give us your comments:
Information will be held confidential. Part No. 09LPWTY

World Marketing of America, Inc. PO Box 192, 12256 William Penn Hwy.
Tel) 1-800-776-9425 www.worldmkting.com
SAVE THIS CARD!
World Marketing of America, Inc. PO Box 192, 12256 William Penn Hwy.
Place Postage · Stamp · Here

gch480
RA18 SERIES
Item/Model Number Part No. Item/Model Number Part No.

18.Knob


7.Gas Valve





Pages referenced in this manual — manufacturer, support and downloads.
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| When ignitor is depressed there is no spark at ODS pilot. | 1. Ignitor electrode positioned wrong. 2. Ignitor electrode broken. 3. Ignitor cable pinched or broken. 4. Ignitor cable not connected to ignitor electrode. 5. Ignitor defective. | 1. Reposition ignitor electrode. 2. Replace electrode. 3. Free ignitor cable, if damaged, replace. 4. Connect cable to electrode. 5. Replace ignitor. | p.13 |
| When control knob is pressed in and turned counterclockwise to pilot and piezo is depressed, pilot does not light. | 1. Gas supply turned off. 2. Control knob not in pilot position. 3. Control knob not pressed in while in pilot position. 4. ODS pilot is clogged. 5. Air in gas lines. | 1. Turn gas supply on. 2. Turn control knob to pilot position. 3. Press in control while in pilot position. 4. Call a qualified service technician. 5. Purge gas lines and repeat ignition operation. | p.13 |
| ODS pilot lights but flame goes out when control knob is released. | 1.Control knob not pressed long enough. 2. Safety interlock is triggered. 3. Pilot flame not touching the thermocouple. Problem could be result of one or both of the following: • Partially clogged ODS pilot orifice. • Low gas pressure. 4. Thermocouple damaged. 5. Thermocouple connection loose at gas control valve. 6. Gas control valve damaged. | 1. After ODS pilot lights, keep control knob pressed in approximately 30 seconds. 2. Wait one minute, repeat ignition operation. 3. Contact your gas company, gas supplier or qualified service technician. 4. Replace thermocouple. 5. Hand tight until snug then tighten 1/4 turn with a wrench. 6. Replace gas control. | p.13 |
| Burner does not light after ODS pilot is lit. | 1. Burner orifice clogged. 2. Gas supply pressure is very low. | 1. Clean burner orifice. 2. Contact gas supplier. | p.13 |
| Delayed ignition. | 1. Main burner carry over ports clogged. 2. Gas supply pressure is very low. | 1. Clean main burner ports. 2. Contact gas supplier. | p.13 |
| Burner backfiring during operation. | 1. Burner orifice is clogged. 2. Burner ports damaged. | 1. Clean burner orifice. 2. Replace burner. | p.13 |
| Yellow flames during burner operation. | 1. Not enough air. | 1. Check air passageways and burner for dirt and debris. (Refer to Maintenance section) | p.13 |
| Burner plaque(s) does not glow. | 1. Plaque(s) is damaged. 2. Inlet gas pressure too low. 3. Control knob set between locked positions. | 1. Replace burner. 2. Contact local gas supplier. 3. Turn control knob until it locks at desired setting. | p.13 |
| Slight smoke and odor during Initial operation. | 1. Residues from manufacturing processes. | 1. Will stop after a few hours of operation. | p.13 |
| Heater produces a whistling noise when burner is lit. | 1. Air passageways blocked. 2. Air in gas line. | 1. Check minimum installation clearances and air passageways for debris. 2. Operate burner until the air is completely purged. | p.13 |
| Heater produces a clicking noise just after burner is lit or turned off. | 1. Metal expanding and contracting. | 1. This is common with heaters. If noise is excessive, contact a qualified, service technician. | p.13 |
| Gas odor even when control knob is in OFF position. | 1. Gas leaks. Refer to front of page Warnings. 2. Gas control defective. | 1. Locate and correct leaks immediately. 2. Replace gas control | p.14 |
| Gas odor during combustion. | 1. Foreign matter in gas or on burner ports. 2. Heater burning vapors form paint, impurities in air. 3. Gas leaks, refer to front page Warnings | 1. Check gas passage way and burner. 2. Ventilate room, stop storing and using odor causing products near heater. 3. Locate and correct leaks immediately. | p.14 |
| Heater shuts off on ODS. | 1. Not enough fresh air is available. 2. Low gas pressure. 3. ODS pilot partially clogged. | 1. Open window. 2. Contact gas supplier. 3. Clean the pilot. | p.14 |