GAS HEATERS OWNER’S OPERATION AND INSTALLATION MANUAL
flammable vapors and liquids in the vicinity of this or any other appliance.
formed by a qualified installer, service agency, or the gas supplier.
Save this manual for future reference.
® · ®



Carbon monoxide poisoning may lead to death!
Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, or nausea. If you have these signs, the heater may not be operating or venting properly. Get fresh air at once! Have heater or heater venting system serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes.
Propane Gas: Propane gas is odorless. An odor-making agent is added to propane gas. The odor helps you detect a propane gas leak. However, the odor added to propane gas can fade. Propane gas may be present even though no odor exists.
Make certain you read and understand all Warnings. Keep this manual for reference. It is your guide to safe and proper operation of this heater.



Figure 1 - Vented Propane Gas Heater, Radiant Front
Figure 2 - Vented Propane Gas Heater, Rear View

Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of the following:
*Available from: American National Standards Institute, Inc., 1430 Broadway, New York, NY 10018; National Fire Protection Association, Inc., Batterymarch Park, Quincy, MA 02269.
Piezo Ignition System This heater has a piezo ignitor. This system requires no matches, batteries, or other sources to light heater.
Thermostatic Heat Control This heater has a thermostat sensing bulb and a control valve. This results in the greatest heating comfort. This can also result in lower gas bills.
CHECK GAS TYPE Use only propane gas. If your gas supply is not propane, do not install heater. Call dealer where you bought heater for proper type heater.
INSTALLATION ITEMS Before installing heater, make sure you have all items below.
* An A.G.A. design-certified manual shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional A.G.A. design-certified manual shutoff valve from your dealer. See Accessories, page 37.

WARNING ICON G 001 WARNING
Maintain the minimum clearances shown in Figure 3, below. If you can, provide greater clearances.
If you install the heater in a home garage
For convenience and efficiency, install heater
6" Minimum from Back
48" Minimum from Front of Heater
Figure 3 - Heater Clearances

A qualified service person must install the venting system for this heater. If venting system is not properly installed and maintained, the vent safety shut-off system will pre- vent the heater from running. Follow all local codes.
This heater has a vent safety shut-off system. This system shuts off the heater gas supply if you do not vent heater properly or the venting system is blocked. Do not operate heater if not properly vented. Do not tamper with the vent safety shut-off system. Carbon monoxide poisoning and death may result.
When venting this heater, follow the safety information listed below.

WARNING ICON G 001 WARNING
Do not vent heater in any of the following ways (see Figure 4).
Heater must be vented to the out- doors. Never vent heater to another room or inside a building.
The vertical section of vent pipe must extend at least two feet above the highest point of any roof within ten feet.
Never extend vent pipe horizontally through outside wall and terminate. You must connect a vertical run of vent pipe to the horizontal run. The vertical run must be at least 25% longer than the horizontal run.
Never extend vent pipe horizontally through a chimney or flue. You must connect a vertical run of vent pipe to the horizontal run. The vertical run must be at least 25% longer or five feet minimum than the horizontal run.
Less than 5' between elbows
Vertical run of pipe must be at least five feet from elbow to elbow.
Figure 4 - Improper Venting Systems Continued

Proper Size Vent To safely vent heater, the vent connector pipe must be the same diameter as the draft hood outlet on the rear of the heater. Pipe that is too small can cause flue gas to spill from the heater. Fasten vent connector to the draft hood outlet with a sheet metal screw.
Prefabricated or Masonry All-Fuel Chimney - This is a masonry chimney or a residential-type prefabricated chimney. Only use prefabricated chimneys listed by Underwriters Laboratories (UL), Inc.
Type-B Vent - These vents are made of noncombustible, corrosion resistant material. They are certified by a nationally recognized testing agency. Type-B vents are double-walled pipe. Clearances to combustible construction must be in accordance with the listing of the particular type-B vent. Type-B vents are cur- rently listed as B-1, B-1 1/2, and B-2.
The illustrations below show both vent types. The illustration shows typical construction of each type of venting system. Minimum clearances and lengths are added to the illustrations.
Terminate at least 5' above draft hood. If vent extends over 5' above roof, support with guy wires or braces.
Seal Around Collar and Flashing
Vent Cap Must Be At Least 2 Feet Above Highest Point Within 10 Feet.
Maintain Listed Clearance of Vent
Position Firestop Support Laterals
Maintain Listed Clearance of Vent
53" Min.
5' Min.
6" Min.
Type-B Vent Prefabricated or Masonry All-Fuel Chimney
Figure 5 - Typical Construction of Venting Systems

WARNING ICON G 001 WARNING
A qualified service person must connect heater to gas supply. Follow all local codes.
Never connect heater directly to the propane supply. This heater requires an external regulator (not sup- plied). Install the external regulator between the heater and propane supply.
The installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incoming gas pressure, heater regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure 6. Pointing the vent down protects it from freezing rain or sleet.
TANK
VENT
Figure 6 - External Regulator with Vent Pointing Down
The gas supply line to your heater must be 1/2 inch in diameter or larger. If the supply line branches to serve two or more heaters, the line from the branch back to the external regulator must be doubled or tripled, etc., in size (depending upon the number of heaters). Example for 1/2 inch diameter supply line: If the supply line branches to serve two heaters, the line diameter from the branch back to the external regulator must be at least 1 inch. If three heaters are served, the line diameter from the branch back to the external regulator must be at least 1 1/2 inches.
External Regulator · Vent Pointing Down

Installation must include a manual shutoff valve, ground joint union, plugged 1/8" NPT tap and a sediment trap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 7).
Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves.
Install sediment trap in supply line as shown in Figure 7. Locate sediment trap where it is within reach for cleaning. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into heater controls. If sediment trap is not installed or is installed wrong, heater may not run properly.
Acceptable construction of inlet gas line
From External Regulator (11" W.C. Min** to 14" W.C. Max)
Manual Shutoff Valve * Ground Joint Union
Preferred construction of inlet gas line
Reducer Bushing to 1/8" NPT Test Gauge Connection*
From External Regulator (11" W.C. Min** to 14" W.C. Max)
1/8" NPT Plug Tap
Figure 7 - Gas Connection
* An A.G.A. design-certified manual shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional A.G.A. design-certified manual shutoff valve from your dealer. See Accessories, page 37.
** For purposes of input adjustment.

Test Pressures In Excess of 1/2 PSIG 1. Disconnect heater and its individual manual shutoff valve from gas supply pipe. Pressures in excess of 1/2 PSIG will damage heater regulator. 2. Cap off open end of gas pipe where manual shutoff valve was connected. 3. Pressurize supply piping system by either using compressed air or opening propane supply tank valve. 4. Check all joints of gas supply piping system. Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak. 5. Correct all leaks at once. 6. Re-connect heater and manual shutoff valve to gas supply. Check re-connected fittings for leaks.
Test Pressures Equal To or Less Than 1/2 PSIG 1. Close manual shutoff valve (see Figure 8). 2. Pressurize supply piping system by either using compressed air or opening propane supply tank valve. 3. Check all joints from propane supply tank to manual shutoff valve. Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak. 4. Correct all leaks at once.
Pressure Testing Heater Gas Connections 1. Open manual shutoff valve (see Figure 8). 2. Open propane supply tank valve. 3. Make sure control knob of heater is in the OFF position. 4. Check all joints from manual shutoff valve to control valve on heater. Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak. 5. Correct all leaks at once. 6. Light heater (see Operating Heater, pages 21 through 23). Check the rest of the internal joints for leaks. 7. Turn off heater (see To Turn Off Gas to Appliance, page 23).
Figure 8 - Manual Shutoff Valve
PO On Position · Off Position

Lower Front Access Area
Lower Front Access Panel Glass Retaining Channel
Figure 9 - Location of Radiants
Figure 10 - Position of Radiant

INSTALLING GLASS PANEL For Radiant Models Only 1. Locate the glass panel package inside the back of the heater.
Glass panels may have sharp edges. Handle with care.
Lower Front Access Area
Figure 11 - Inserting Glass Panels

WARNING ICON G 001 CAUTION Make sure you insert top edge of glass panels into the upper glass retaining channel. Do not install glass panels with top edge of glass in front of the upper glass retaining channel. Glass panels will not automatically go into the channel. You must guide the glass panels into it. Incorrect installation will damage front of heater due to excess temperatures.
Upper Glass Retaining Channel
Lower Glass Retaining Channel
Lower Front Access Area
Figure 12 - Inserting Top Edge of Glass Panel into
Upper Glass Retaining Channel
Lower Glass Retaining Channel
Figure 13 - Inserting Glass into Lower Retaining Channel
Glass Panel · Glass Panel

Today’s homes are built more energy efficient than ever. New materials, increased insulation, and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in. During heating months, home owners want their homes as airtight as possible.
While it is good to make your home energy efficient, it is not good to make it too airtight. Your home needs to breath. If your home is too airtight, fresh air has little chance of entering in. This could be dangerous if you have fuel-burning appliances. These appliances need fresh, outside air for proper combustion and ventilation.
Exhaust fans, fireplaces, clothes dryers, and fuel-burning appliances draw air from the house to operate. This heater is a fuel-burning appliance. It uses air from inside the house for combustion. It also uses this air as a draft for venting. This draft air helps move combustion gases through the vent pipe to the outdoors. If your house is too airtight, there is not enough fresh air for these items to use. Fresh air may draw back into the house through venting flues and chimneys. This will keep fuel- burning appliances from venting properly. This may cause them to release poison- ous carbon monoxide gas into your home. It is very important to provide enough fresh air to run all fuel-burning appliances.
Carbon monoxide poisoning may lead to death!
Carbon monoxide is a colorless, odorless gas. Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, and/or nausea. If you have these signs, the heater may not be operating or venting properly. Get fresh air at once! Have heater or heater venting system serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, persons with heart and lung disease and anemia, those under the influence of alcohol, and those at high altitudes.

In the absence of local codes, use the following excerpts from the National Fuel Gas Code NFPA 54/ANSI Z223.1, Air for Combustion and Ventilation.
AND VENTILATION
Example 1: Locating Heater in Unconfined (Open) Area
NOTICE An unconfined area has a minimum air volume of 50 cubic feet for each 1000 BTU/Hr input rating of all appliances in the area (cubic feet equals length x width x height of area). Include adjoining rooms only if there are no doors between the rooms or if you add ventila- tion grills between the rooms (see Ventilating Confined Area, page 20).
In an open area, the air that leaks around doors and windows may provide enough fresh air for combustion and ventilation.
Draft Hood Spillage Test Follow the steps below to see if enough fresh air is available. 1. Close all windows and doors. 2. If you have a fireplace, start a fire. Build fire until flames are burning strongly. 3. Turn on all exhaust fans. These include exhaust fans for kitchen, bathroom, water heaters (gas or electric), etc. 4. Turn on all vented gas appliances. These include any room heaters, water heaters, clothes dryer, etc. 5. Wait ten minutes for drafts to regulate. 6. Check for draft-hood spillage at each vented gas appliance. Do this by holding a lit match two inches from the draft opening (see Figure 14). If match flame pulls toward the draft hood, there is no spillage. If match flame blows away from the draft hood, there is spillage. This is a hazardous condition. See Draft Hood Spillage, page 19.
Figure 14 - Checking for Draft Spillage
No Draft Hood Spillage: This shows there is enough fresh air in area for appliances. Turn off all exhaust fans and appliances if desired.

Draft Hood Spillage: This is a hazardous situation. Draft hood spillage re- leases poisonous carbon monoxide gas into your home.
AND VENTILATION
If draft hood spillage occurs, check for blocked flue connectors, vent pipes, and chimneys. If you find blockage, remove. Test again for spillage. If spillage still occurs or there was no blockage, you need more fresh, outside air in the house. You must provide additional fresh-air ventilation. Follow the steps below at once. A. Open a window near the appliance(s) at least two inches. Test again for
spillage. If spillage does not stop, open window more and retest. If spillage stops, keep window open while running appliance(s). Supply fresh, outside air by a permanent method as soon as possible. If spillage still occurs, leave window open and go to next step. B. If you have a fireplace, open a window or door near it at least two inches.
Test again for spillage. If spillage does not stop, open window or door more and retest. If spillage stops, keep window or door open while using fire- place. Supply fresh, outside air by a permanent method as soon as possible. If spillage still occurs, leave window or door open and go to next step. C. If you have kitchen and bathroom exhaust fans, turn them off. Test again for
spillage. If spillage stops, do not use exhaust fans. Turn off circuit breakers for fans if possible. Permanently supply fresh, outside air as soon as possible.
Providing Permanent Fresh-Air Ventilation If draft hood spillage occurs, you must permanently supply fresh, outside air to the inside of your house. Provide extra fresh air by using ventilation grills or ducts. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces. If you install this heater in an area with other gas appliances, you must total the BTU/Hr input rating of all appliances. Follow the National Fuel Gas Code NFPA 54/ANSI Z223.1. It lists fresh-air requirements for fuel-burning appliances.
Chimney or Gas Vent Outlet Air
Inlet Air Ventilated Crawl Space
Figure 15 - Ventilation Air from Outdoors

If you install this heater in a confined area, you must provide additional fresh air.
This fresh air would come from an adjoining open area or outdoors.
When ventilating to an adjoining open area, you must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two areas. Follow the National Fuel Gas Code NFPA 54/ANSI Z223.1. It lists fresh-air requirements for fuel-burning appliances.
Ventilation Grills Connecting Two Rooms to Meet Unconfined Space
Grills into Closet for Hot Water
Fresh Air Duct into Crawl Space in Furnace Area or in Closet with Water Heater
Figure 16 - Ventilation Air from Inside Building
After providing ventilation between rooms, check for draft hood spillage (see Draft Hood Spillage Test, page 18). If draft hood spillage still occurs, provide more ventilation between rooms or provide permanent ventilation from outdoors. See Providing Permanent Fresh-Air Ventilation, page 19.

A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. WHAT TO DO IF YOU SMELL GAS
PILOT VEILLEUSE
ARRÊTER
HIGH HAUT LOW BAS
Figure 17 - Control Knob and Ignitor Button
Ignitor Button · Control Knob

Figure 18 - Viewing Pilot

(For Models with Blower)
Shutting Off Burner Only (pilot stays lit)
Shutting Off Heater

Check pilot flame pattern and burner flame pattern often.
Figure 19 shows a correct pilot flame pattern. Figure 20 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will prevent the thermocouple from getting hot, causing the heater to shut down.
FLAME
Figure 19 - Correct Pilot
Figure 20 - Incorrect
If pilot flame pattern is incorrect, as shown in Figure 20
BURNER FLAME PATTERN Note: To view burner flame, look through front glass of heater.
Figure 21, page 25, shows a correct burner flame pattern. Figure 22, page 25, shows two incorrect burner flame patterns. The two incorrect flame patterns show ragged yellow flames and flames lifting off of burner.
Thermocouple Thermocouple · Flame Pattern · Pilot Flame Pattern


If burner flame pattern is incorrect, as shown in Figure 22

COMBUSTION CHAMBER AND BURNER Clean the combustion chamber and burner if you have run the heater with a high yellow flame. Incomplete combustion from lack of air causes the yellow flame. This will deposit soot inside the combustion chamber and on the burner. To clean combustion chamber and burner, you must remove the burner from heater. See Service Procedures, page 33, to remove burner. After removing burner, blow inside of combustion chamber clean with compressed air. Clean burner with a steel-wire brush. Blow soot from burner with compressed air.
PILOT Use a vacuum cleaner, compressed air, or small, soft-bristled brush to clean.
BURNER ORIFICE Use a vacuum cleaner, compressed air, or small, soft-bristled brush to clean. You can also use a tooth pick to clean orifice. Do not enlarge or damage orifice hole.
PILOT AND BURNER FLAME Check the pilot and burner flame monthly. Make sure pilot and burner flame is burning correctly. See Inspecting Pilot and Burner Flame, page 24.
VENTING SYSTEM Check the venting system at least once a year. Make sure joints are secure and vent pipe is in good condition. Do not obstruct combustion and ventilation air entering the rear of heater.
BLOWER MOTOR (For Models with Blower) The motor on a new blower is properly lubricated at the factory. The first heating season, the motor will need no additional care. At the beginning of each season afterwards, place a few drops of SAE 20 motor oil in the lubrication holes of motor. Locate the lubrication holes at front and rear of motor on motor casing.

POSSIBLE CAUSE
REMEDY
When ignitor button is pressed, there is no spark at pilot.
When ignitor button is pressed, there is spark at pilot but no ignition.

POSSIBLE CAUSE
REMEDY
Pilot lights but flame goes out when control knob is released.
justed pilot flame B) Low gas pressure C) Dirty or partially
clogged pilot 7. Thermocouple dam- aged. 8. Control valve damaged.
Burner does not light after pilot is lit.

POSSIBLE CAUSE
REMEDY
Delayed ignition of burner.
Burner backfiring during combustion.
Yellow flame during burner combustion
Flame lifting during combustion.
Slight smoke or odor during initial opera- tion.

POSSIBLE CAUSE
REMEDY
Burner fails to respond to thermo- stat.
Heater produces a whistling noise when burner is lit.
Heater produces a clicking/ticking noise just after burner is lit or shut off.

POSSIBLE CAUSE
REMEDY
Heater produces unwanted odors.
Heater shuts off in use.
Gas odor even when control knob is in OFF position.
Gas odor during combustion.

Turn off and unplug heater and let cool before servicing. Unless you need gas supply for testing, shut off manual shutoff valve before servicing. Only a qualified service person should service and repair heater and venting system. Removing Control Valve and Burner Tube
1. Shut off gas supply to heater. 2. Remove lower front access panel on heater. 3. Disconnect burner tube from orifice holder (see Figure 23). 4. Remove pilot gas line from control valve (see Figure 23). 5. Disconnect wire connec- tors from thermocouple interrupter (see Figure 23). 6. Remove thermocouple and thermocouple inter- rupter from control valve. 7. Remove cotter pin from control valve. This releases the control rod from valve (see Figure 23). 8. Remove the two mounting screws from control valve mounting bracket (see Figure 23). 9. Remove assembly from the rear of heater. 10. To reinstall, reverse above steps. Turn on gas to heater and check for gas leaks. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once. 11. Replace lower front access panel.
Figure 23 - Removing Control Valve and Burner Tube

1. Shut off gas supply to heater. 2. Remove lower front access panel on heater. 3. Disconnect burner tube from orifice holder (see Figure 24). 4. Remove orifice holder from burner (see Figure 24). 5. Remove pilot burner bracket nuts and remove pilot assembly (see Figure 24). 6. Move burner to the right for clearance. Rotate burner 90° and remove burner through lower front access opening. 7. To reinstall, reverse above steps. Turn on gas to heater and check for gas leaks. Apply a mixture of liquid soap and water to all joints. Bubbles form- ing show a leak. Correct all leaks at once. 8. Replace lower front access panel.
Pilot Burner Bracket Nut
Figure 24 - Removing Burner Tube, Orifice Holder, and Pilot Burner Assembly
(35,000 BTU/Hr Burner Shown)


1. Shut off gas supply to heater. 2. Remove lower front access panel on heater. 3. Disconnect burner tube from orifice holder (see Figure 25). 4. Remove orifice holder from burner (see Figure 25). 5. Use socket or open-end wrench to remove the old orifice from the orifice holder. 6. Clean and replace orifice, or replace with new orifice. 7. Turn on gas to heater and check for gas leaks. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once. 8. Replace lower front access panel.
Figure 25 - Orifice Location (35,000 BTU/Hr Burner Shown)

You may have further questions about installation, operation, or troubleshooting. If so, contact DESA International’s Technical Service Department at 1-800-323- 5190.
35,000 BTU/Hr 50,000 BTU/Hr 65,000 BTU/Hr Model Model Model BTU 35,000 50,000 65,000 Type Gas Propane Only Propane Only Propane Only Ignition Piezo Piezo Piezo Pressure Regulator Setting 10.5" W.C. 10.5" W.C. 10.5" W.C. Inlet Gas Pressure
Maximum 14" W.C. 14" W.C. 14" W.C. Minimum 11" W.C. 11" W.C. 11" W.C. Dimensions, Inches
Heater (H x W x D) 25 x 27 1/4 x 16 27 x 32 1/2 x 16 31 x 37 3/4 x 16 Shipping Weight (pounds) 97 133**/120 158**/145 Flue Vent Size 4" dia. 4" dia. 5" dia. Orifice Size 52 drill, ø .0635 46 drill, ø .081 2.4 mm, ø .0945
** When equipped with blower
When gas pressure is too low
When gas quality is bad
You may feel your gas pressure is too low or gas quality is bad. If so, contact your local propane gas supplier.

Parts Under Warranty Contact your nearest dealer or call DESA International’s Technical Service De- partment at 1-800-323-5190.
When calling DESA International, have ready
Parts Not Under Warranty Contact your nearest dealer. If they can’t supply original replacement part(s), either contact your nearest Parts Central (below) or call DESA International’s Parts Department at 1-800-972-7879 for information.
When calling DESA International, have ready
These Parts Centrals are privately owned businesses. They have agreed to support our customer’s needs by providing original replacement parts and accessories. For certain parts, some Parts Centrals may refer you to a dealer in your area. When calling a Parts Central, ask for the Parts Department.
Howard Industries 1514 South Maple Ave. Los Angeles, CA 90015 213-747-5121
Washer Equipment Co. 1715 Main Street Kansas City, MO 64108 KS, MO, AR 816-842-3911
Warmer Image 208 Carter Drive, Unit 21 West Chester, PA 19382 215-696-2670 1-800-368-0803
Victor Manufacturing 42 Rumsey Road E. Hartford, CT 06108 NY, NJ, DE, PA, MD 203-289-4223 Controlled Engineering 299 Roosevelt Road Glen Ellyn, IL 60137 708-469-7300 Portable Heater Parts 342 N. Country Rd. 400E Valparaiso, IN 46383 All States 219-462-7441 1-800-362-6951 FBD 601 Hope Street Bowling Green, KY 42101 502-796-8406 1-800-654-8534 American Air Dist. 537 W. 62nd Street Shreveport, LA 71108 318-861-0634 Master Service Center 1184 Wilson Grand Rapids, MI 49504 616-791-4760 1-800-446-1446
Controls, Inc. 6820 Glenwood Ave. Raleigh, NC 27612 NC, SC, VA, MD 919-787-2242 1-800-334-5886 Taratin Tank Co. P.O. Box 6129 Freehold, NJ 07728 908-780-9340 East Coast Energy 833 Broadway W. Long Branch, NJ 07764 908-870-8809 1-800-755-8809 ATP Services 990 Avenue of Americas New York, NY 10018 212-967-6255 Dayton Hardware P. O. Box 275 North Dayton Station Dayton, OH 45404 All States 513-258-3721 OH only 1-800-762-3426 Central Air Supply 424 North Rockwell Oklahoma City, OK 73127 405-495-0014
LaPorte’s Parts & Service 2444 North 5th Street Hartsville, SC 29550 803-879-3009 Parts Department Cans Unlimited, Inc. P. O. Box 645 Taylor, SC 29687 All States 803-879-3009 1-800-845-5301 Dealers LP Equip. Co. P.O. Box 341145 Bartlett, TN 38184 AL, TN 901-386-8780 Capitol Hydronic Supply 104 West Jefferson Street Falls Church, VA 22046 703-532-1622 Tuco Industrial Products P.O. Box 5076 Lynwood, WA 98046 206-743-9533 1-800-735-1268 Auer Steel Supply 2935 W. Silver Spring Dr. Milwaukee, WI 53209 414-463-1234

Purchase these heater accessories from your local dealer. If they can not supply these accessories, contact your nearest Parts Central (see page 36). You can also write to the address listed on the back page of this manual for information.
BLOWER KIT - PART NUMBER GA6010 For all models. Provides better heat distribution. Makes heater more efficient. Complete installation and operating instructions provided with blower.
MANUAL SHUTOFF VALVE - GA5010 For all models. Manual shutoff valve with 1/8" NPT tap.


This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Ordering Replacement Parts on page 36 of this manual.
PART NUMBER FOR KEY NO. CGR65BPA CGR65PA CGR50BPA CGR50PA CGR35PA DESCRIPTION QTY.
1 099998-01 —— 099998-01 —— —— Fan Switch 1
2 100045-01 —— 100045-01 —— —— Wire Harness 1
3 231942 —— 231942 —— —— Fan Limit Switch 1
4 M11084-38 —— M11084-38 —— —— Screw, #8-18 x 3/8" 2
6 M11084-26 —— M11084-26 —— —— Screw, #10-16 x 3/8" 6
7 531001 —— 531001 —— —— Blower Pan 1
8 098304-01 —— 098304-01 —— —— Screw, #10-24 x 3/8" 1
9 099123-01 —— 099123-01 —— —— Thermobulb Clip 1

This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Ordering Replacement Parts on page 36 of this manual.
Cabinet Assembly for Radiant Models
PART NUMBER FOR KEY NO. CGR65BPA CGR65PA CGR50BPA CGR50PA CGR35PA DESCRIPTION QTY.
1 100202-03 100202-03 100202-02 100202-02 100202-01 Lower Front Panel 1 2 098304-01 Screw, #10-16 x 3/8" 2 3 100053-03BS 100053-03BS 100053-02BS 100053-02BS 100053-01BS Hearth Assembly 1 (includes items 5 & 7) 4 100204-03 100204-03 100204-02 100204-02 100204-01 Top Panel 1 5 098304-02 Screw, #6-20 x 3/8" 2 6 M11084-26 —— Screw, #10-16 x 3/8" 17 —— M11084-26 Screw, #10-16 x 3/8" 19 7 100205-03BS 100205-03BS 100205-02BS 100205-02BS 100205-01BS Glass Guard 1 8 100203-03 100203-03 100203-02 100203-02 100203-01 Cabinet Assembly 1 9 099123-01 Thermobulb Clip 2 10 100101-03BS 100101-03BS 100101-02BS 100101-02BS 100101-01BS Cabinet Back 1 11 —— 099997-01 —— 099997-01 099997-01 Switch Plug 1
099988-02 Lighting Instructions Decal 1 099987-02 Control Position Decal 1 100154-02 Warning Decal 1



This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Ordering Replacement Parts on page 36 of this manual.
PART NUMBER FOR KEY NO. CGR65BPA CGR65PA CGR50BPA CGR50PA CGR35PA DESCRIPTION QTY.
1 100729-03 100729-03 100729-02 100729-02 100729-01 Combustion Chamber 1
2 098324-02 Control Knob 1
3 097159-01 Piezo Ignitor 1
4 098271-05 Ignitor Cable 1
5 099974-03 099974-03 099974-02 099974-02 099974-01 Control Rod 1
6 063017 063017 100481-01 100481-01 063015 Limit Switch Bracket 1
7 M11084-26 M11084-26 —— —— M11084-26 Screw, #10-16 x 3/8" 6
—— —— M11084-26 M11084-26 —— Screw, #10-16 x 3/8" 5
8 099986-02 099986-02 099986-01 099986-01 099986-01 Wire Assembly 1
9 100000-01 Cotter Pin 1
10 231939 231940 Limit Switch 1
11 M11084-38 —— Screw, #8-18 x 3/8" 3
—— M11084-38 Screw, #8-18 x 3/8" 2
12 099211-01 Screw, #10-16 x 2 1/4" 2
13 100207-02 Control Valve 1
14 098265-01 Elbow 1
15 098936-02 Thermocouple Interrupter 1
16 100028-02 Pilot Tubing 1
17 100307-01 Thermocouple 1
18 171176 Burner Tube 1
19 530988 Control Bracket 1
20 100309-01 Orifice Holder 1
21 180252 180252 530124 530124 100469-01 Orifice 1
22 100706-01 100706-01 100385-01 100385-01 100384-01 Burner Assembly 1
23 100310-01 Pilot Mounting Bracket 1
24 100308-02 Pilot (Includes 30 & 31) 1
25 M12461-25 Screw, 10-32 x 1/4" 2
26 098249-01 Nut, M5 x 0.8 2
27 101342-03 101342-03 101342-02 101342-02 101342-01 Glass Panel Package
28 100772-01 100772-01 —— —— —— Radiant 5
—— —— 100772-01 100772-01 —— Radiant 4
—— 100772-01 Radiant 3
29 530192 Glass Spring 2
30 100468-01 Pilot Electrode 1
31 100465-01 Electrode Nut 1
(Includes Retainer) 1



Always specify model and serial numbers when communicating with the factory. We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied.
LIMITED ONE YEAR WARRANTY This DESA product is warranted to the original purchaser to be free from defect in material and workmanship under normal use and maintenance for a period of one year from the date of installation whether or not actual use begins on that date. It is the responsibility of the consumer/owner to establish the warranty period. You are required to furnish proof of installation date, which may be a Bill of Sales or other payment record which verifies the original installation. A new or remanufactured part to replace any defective part will be provided, at DESA’s sole option, without charge for the part itself, FOB the shipping point. The exchanged part will be warranted for only the unexpired portion of the original warranty. Defective parts must be returned to DESA, transportation charges prepaid, (DESA is not responsible for any freight charges), where DESA will establish to its sole satisfaction that the part was or became defective under normal use and maintenance. No reimbursement will be made for transportation, diagnostics, shipping, handling, or other incidental expenses. This warranty applies only to the product in its original installation location and is voided if the product is reinstalled elsewhere.
LIMITED FOUR YEAR WARRANTY ON COMBUSTION CHAMBER During the second through fifth years after the date of original installation, DESA further warrants the combustion chamber against defects in material and workmanship under normal use and maintenance. A replacement combustion chamber will be provided under the same conditions as stated in the one year warranty.
LIMITATION OF WARRANTIES All implied warranties (including implied warranties of merchantability) are hereby limited in duration to the period for which each limited warranty is given. Some states do not allow limitations on how long an implied warranty lasts so the above limitations may not apply to you. The expressed warranties made in this warranty are exclusive and may not be altered, enlarged, or changed by any distributor, dealer, or other person whomsoever.
DESA WILL NOT BE RESPONSIBLE FOR: 1. Normal maintenance as outlined in the owner’s operation and installation manual including cleaning of component parts; such as, orifices and burners. 2. Failure to start and/or operate due to voltage or gas condition, blown fuses, open circuit breakers, loose or disconnected wires, low gas pressure, or other damages due to inadequacy or interruption of electrical service or gas supply. 3. Damage or repairs required as a consequence of faulty or incorrect installation not in conformance with DESA instructions. 4. Damage as a result of floods, winds, lightning, accidents, corrosive atmosphere, or other conditions beyond the control of DESA. 5. Parts or accessories not supplied by DESA. 6. Costs incurred in gaining access to the heater. 7. Damage or repairs needed as a consequence of any misapplication, abuse, unreasonable use, unauthorized alteration, improper servicing, improper operation, or failure to provide reasonable and necessary maintenance. 8. Freight charges incurred from parts replacement. 9. DESA product installed outside the Continental U.S.A. and Alaska. 10. DESA products whose serial number has been altered, defaced, or removed. 11. Fuel or electricity costs or increases in such costs from any reason whatsoever. 12. Any special, indirect or consequential property, economic, or commercial damage of any nature whatsoever. Some states do not allow the exclusion of incidental or consequential damages, so the above limitation may not apply to you. No representative, dealer, or other person is authorized to assume for DESA International any additional, different, or other liability in connection with the sale of this DESA product. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. For more information about this warranty, write:
2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004