EN
Desa Tech logo
Official user manual

Desa Tech CGP11

24 pages·215 KB·Gas Heater·PDF·ENDEFRITNLJA
Desa Tech CGP11
Table of Contents 73 sections VENT-FREE PROPANE GAS HEATER · OWNER’S OPERATION AND INSTALLATION MANUAL · Model: CGP11 · — Do not store or use gasoline or other · … ShowHide
VENT-FREE PROPANE GAS HEATERp.1OWNER’S OPERATION AND INSTALLATION MANUALp.1Model: CGP11p.1— Do not store or use gasoline or otherp.1— WHAT TO DO IF YOU SMELL GASp.1G S Ap.1— Installation and service must be per-p.1I Ep.1CONTENTS SECTION PAGEp.2WARNING ICON G 001 DANGERp.2SAFETY INFORMATIONp.3WARNING ICON G 001 WARNINGS Continuedp.3Continuedp.3PRODUCT IDENTIFICATIONp.4PRODUCT FEATURESp.4INSTALLINGp.5NOTICEp.5TO WALLp.5WARNING ICON G 001 WARNINGp.5WARNING ICON G 001 CAUTIONp.5CEILINGp.6FLOORp.6JOINING WALLp.6CONNECTINGp.9TO GAS SUPPLYp.9CHECKINGp.10GAS CONNECTIONSp.10PRESSURE TESTING GAS SUPPLY PIPING SYSTEMp.10PRESSURE TESTING HEATER GAS CONNECTIONSp.11ON POSITIONp.11OFF POSITIONp.11OPERATINGp.12FOR YOUR SAFETY READ BEFORE LIGHTINGp.12HEATERp.12WHAT TO DO IF YOU SMELL GASp.12LIGHTING INSTRUCTIONSp.12OFFp.12PILOTp.12IGNp.12LOWp.12HIGHp.12TO SELECT HEATING LEVELp.14TO TURN OFF GAS TO APPLIANCEp.15MANUAL LIGHTING PROCEDUREp.15INSPECTINGp.15BURNERp.15GRH/OV 007 GOOD PILOT/LPp.15GRH/OV 008 BAD PILOT/LPp.15CLEANINGp.17AND MAINTENANCEp.17ODS/PILOT AND BURNER ORIFICEp.17CABINETp.17TROUBLESHOOTINGp.17OBSERVED PROBLEMp.17POSSIBLE CAUSEp.17REMEDYp.17SERVICEp.20SPECIFICATIONSp.21HINTSp.21REPLACEMENTp.21PARTSp.21PARTS CENTRALSp.22SERVICE PUBLICATIONSp.22PARTS AVAILABLE - NOT SHOWNp.23ILLUSTRATEDp.23PARTS BREAKDOWNp.23HEATER EXPLODED VIEWp.23A Bp.23ODS/PILOTp.23KEEP THIS WARRANTY WARRANTY INFORMATIONp.24LIMITED WARRANTY COMFORT GLOW VENT-FREE RESIDENTIAL GAS HEATERSp.24DESAp.24099401-01 REV. E 9/92p.24
Page 1 of the Desa Tech CGP11 user manual — D
Page 1 · click to enlarge
Page 1

VENT-FREE PROPANE GAS HEATER

OWNER’S OPERATION AND INSTALLATION MANUAL

Model: CGP11

— Do not store or use gasoline or other

flammable vapors and liquids in the vicinity of this or any other appliance.

— WHAT TO DO IF YOU SMELL GAS

  • Do not try to light any appliance.
  • Do not touch any electrical switch; do not use any phone in your building.
  • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
  • If you cannot reach your gas supplier, call the fire department.

D

E

S

G

N

E

R

A

M

A

N

G S A

A

S

O

N

— Installation and service must be per-

S

O

A

T

formed by a qualified installer, service agency, or the gas supplier.

D

E

R

T

F

I E

Save this manual for future reference.

® · ®

Page 2 of the Desa Tech CGP11 user manual — Table of Contents
Page 2 · Contents
Contents

Contents

VENT-FREE PROPANE GAS HEATERp.1OWNER’S OPERATION AND INSTALLATION MANUALp.1Model: CGP11p.1— Do not store or use gasoline or otherp.1— WHAT TO DO IF YOU SMELL GASp.1G S Ap.1— Installation and service must be per-p.1I Ep.1CONTENTS SECTION PAGEp.2WARNING ICON G 001 DANGERp.2SAFETY INFORMATIONp.3WARNING ICON G 001 WARNINGS Continuedp.3Continuedp.3PRODUCT IDENTIFICATIONp.4PRODUCT FEATURESp.4INSTALLINGp.5NOTICEp.5TO WALLp.5WARNING ICON G 001 WARNINGp.5WARNING ICON G 001 CAUTIONp.5CEILINGp.6FLOORp.6JOINING WALLp.6CONNECTINGp.9TO GAS SUPPLYp.9CHECKINGp.10GAS CONNECTIONSp.10PRESSURE TESTING GAS SUPPLY PIPING SYSTEMp.10PRESSURE TESTING HEATER GAS CONNECTIONSp.11ON POSITIONp.11OFF POSITIONp.11OPERATINGp.12FOR YOUR SAFETY READ BEFORE LIGHTINGp.12HEATERp.12WHAT TO DO IF YOU SMELL GASp.12LIGHTING INSTRUCTIONSp.12OFFp.12PILOTp.12IGNp.12LOWp.12HIGHp.12TO SELECT HEATING LEVELp.14TO TURN OFF GAS TO APPLIANCEp.15MANUAL LIGHTING PROCEDUREp.15INSPECTINGp.15BURNERp.15GRH/OV 007 GOOD PILOT/LPp.15GRH/OV 008 BAD PILOT/LPp.15CLEANINGp.17AND MAINTENANCEp.17ODS/PILOT AND BURNER ORIFICEp.17CABINETp.17TROUBLESHOOTINGp.17OBSERVED PROBLEMp.17POSSIBLE CAUSEp.17REMEDYp.17SERVICEp.20SPECIFICATIONSp.21HINTSp.21REPLACEMENTp.21PARTSp.21PARTS CENTRALSp.22SERVICE PUBLICATIONSp.22PARTS AVAILABLE - NOT SHOWNp.23ILLUSTRATEDp.23PARTS BREAKDOWNp.23HEATER EXPLODED VIEWp.23A Bp.23ODS/PILOTp.23KEEP THIS WARRANTY WARRANTY INFORMATIONp.24LIMITED WARRANTY COMFORT GLOW VENT-FREE RESIDENTIAL GAS HEATERSp.24DESAp.24099401-01 REV. E 9/92p.24
Page 3 of the Desa Tech CGP11 user manual — Continued
Page 3 · click to enlarge
Page 3

SAFETY INFORMATION

WARNING ICON G 001 WARNINGS Continued

!

  • 1. Use only propane gas. Do not convert heater to use different fuel type. 2. Do not place propane supply tank(s) inside any structure. Locate propane supply tank(s) outdoors. 3. If you smell gas
  • shut off gas supply
  • do not try to light any appliance
  • do not touch any electrical switch; do not use any phone in your building
  • immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions
  • if you cannot reach your gas supplier, call the fire department 4. Never install the heater
  • in sleeping quarters, a mobile home, or a recreational vehicle
  • where curtains, furniture, clothing, or other flammable objects are less than 36 inches from the front, top, or sides of the heater
  • as a fireplace insert
  • in high traffic areas
  • in windy or drafty areas 5. Always run heater with control knob at LOW or HIGH locked positions. Never set control knob between locked positions. Poor combustion and higher levels of carbon monoxide may result. 6. Open window to admit fresh, outside air when using heater. Open window one or two inches. When used without fresh, outside air, heater may give off carbon monoxide gas. 7. Never run heater in small, closed room. Open door into next room to help ventilate. 8. Keep all air openings in the front and bottom of heater clear and free of debris. This will insure enough air for proper combustion. 9. If heater shuts off, do not relight until you provide fresh, outside air. If heater keeps shutting off, have it serviced. 10. Do not run heater
  • where flammable liquids or vapors are used or stored
  • under dusty conditions 11. Never place any objects on the heater. 12. Surface of heater becomes very hot when running heater. Keep children and adults away from hot surface to avoid burns or clothing ignition. Heater will remain hot for a time after shut-down. Allow surface to cool before touching. 13. Make sure grill guard is in place before running heater. 14. Do not alter heater or its controls. Any change may create a safety hazard. 15. Do not use heater if any part of heater has been under water. 16. Turn off heater and let cool before servicing. Only a qualified service person should service and repair heater. 17. Do not operate heater above elevations of 4,500 feet.

Continued

Page 4 of the Desa Tech CGP11 user manual — PRODUCT FEATURES
Page 4 · click to enlarge
Page 4

PRODUCT IDENTIFICATION

Figure 1 - Vent-Free Propane Gas Heater

LOCAL CODES Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of the National Gas Code ANSI Z223.1, also known as NFPA 54*.

*Available from: American National Standards Institute, Inc.

1430 Broadway New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park Quincy, MA 02269

UNPACKING 1. Remove heater from carton. 2. Remove all protective packaging applied to heater for shipment. 3. Check heater for any shipping damage. If heater is damaged, promptly inform dealer where you bought heater.

PRODUCT FEATURES

Safety Device This heater has a pilot with an Oxygen Depletion Sensor Shutoff System (ODS). The ODS/pilot is a required feature for vent-free room heaters. The ODS/pilot shuts off the heater if there is not enough fresh air.

Piezo Ignition System This heater has a piezo ignitor. This system requires no matches, batteries, or other sources to light heater.

Show 5 more labels / short text on this page
Control Knob · Grill Guard · Burners · Heater Cabinet · Front Panel
Page 5 of the Desa Tech CGP11 user manual — !
Page 5 · click to enlarge
Page 5

INSTALLING

NOTICE

TO WALL

A qualified service person must install heater. Follow all local codes.

CHECK GAS TYPE Use only propane gas. If your gas supply is not propane, do not install heater. Call dealer where you bought heater for proper type heater.

INSTALLATION ITEMS Before installing heater, make sure you have the items below:

  • external regulator (supplied by installer-see page 9)
  • piping (check local codes)
  • sealant (resistant to propane gas)
  • manual shutoff valve *
  • ground joint union
  • test gauge connection * (see Figure 11, page 10)
  • sediment trap
  • tee joint
  • pipe wrench

* An A.G.A. design-certified manual shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. The optional A.G.A. design-certified manual shutoff valve can be purchased from your dealer. See ACCESSORY, page 22.

LOCATING HEATER This heater is designed to be mounted on a wall.

!

WARNING ICON G 001 WARNING

Maintain the minimum clearances shown in Figure 2 (page 6). If you can, provide greater clearances from floor, ceiling, and joining wall.

WARNING ICON G 001 WARNING

!

Never install the heater

  • in sleeping quarters, a mobile home, or a recreational vehicle
  • where curtains, furniture, clothing, or other flammable objects are less than 36 inches from the front, top, or sides of the heater
  • as a fireplace insert
  • in high traffic areas
  • in windy or drafty areas

!

WARNING ICON G 001 CAUTION

Operating heater where impurities in the air (such as tobacco smoke) exist, may discolor walls.

!

  • heater pilot and burner must be at least 18 inches above floor
  • locate heater where moving vehicle will not hit it

Continued

Page 6 of the Desa Tech CGP11 user manual — FLOOR
Page 6 · click to enlarge
Page 6

For convenience and efficiency, install heater

  • where there is easy access for operation, inspection, and service
  • in coldest part of room

CEILING

8" Minimum From Sides Of Heater

Right Side Left Side

Minimum To Top Surface Of Carpeting, Tile Or Other Combustible Material

FLOOR

Figure 2 - Mounting Clearances As Viewed From Front of Heater

INSTALLING HEATER TO WALL Marking Screw Locations 1. Determine where you will locate heater.

!

2. Mark two mounting screw locations on wall (see Figure 3).

10 7/8" Minimum To

JOINING WALL

20 1/4" Minimum To

FLOOR

Figure 3 - Mounting Screw Locations

Show 10 more labels / short text on this page
36" · Minimum · 3" · 7 3/4" · Maintain 8" · Clearance From Wall · Mounting · Screw Locations · Maintain 3" · Clearance From Floor
Page 7 of the Desa Tech CGP11 user manual — CEILING
Page 7 · click to enlarge
Page 7

Installing Two Mounting Screws Note: Wall anchors and mounting screws are in hardware package. The hardware package is provided with heater.

Attaching to wall stud method For attaching mounting screw to wall stud 1. Drill hole at marked location using 9/64" drill bit. 2. Insert mounting screw into wall stud. 3. Tighten screw until 1/16" space (thickness of penny) is between screwhead and wall.

Attaching to wall anchor method Follow instructions below to attach mounting screws to hollow walls (wall areas between studs) or solid walls (concrete or masonry). 1. Drill holes at marked locations using 5/16" drill bit. For solid walls (concrete or masonry), drill at least 1 1/4" deep. 2. Fold wall anchor (see Figure 4).

Figure 4 - Folding Anchor

3. Insert wall anchor (wings first) into hole. Tap anchor flush to wall. 4. For thin walls (1/2" or less), insert red key into wall anchor. Push red key to “pop” open anchor wings (see Figure 5). IMPORTANT: Do not hammer key! For thick walls (over 1/2" thick) or solid walls, do not pop open wings.

Thin Walls (1/4" to 1/2" thick)

Figure 5 - Popping Open Anchor Wings For Thin Walls

5. Tighten two screws until 1/16" space (thickness of penny) is between screwheads and wall (see Figure 6).

Thin or Thick Wall (thick wall shown)

ANCHOR Figure 6 - Tightening Anchors

1/16" Space · Solid Wall

Page 8 of the Desa Tech CGP11 user manual — CEILING
Page 8 · click to enlarge
Page 8

Placing Heater On Mounting Screws 1. Locate two keyhole slots on back panel of heater (see Figure 7). 2. Place large openings of slots over screwheads. Slide heater down until screws are in small portion of slots.

Figure 7 - Location Of Keyhole Slots On Back Panel Of Heater

Removing Front Panel Of Heater 1. Remove two screws near bottom corners of front panel. 2. Lift straight up on grill guard until it stops. Grill guard will slide up about 1/4". 3. Pull bottom of front panel forward, then down.

Figure 8 - Removing Front Panel Of Heater

Installing Bottom Mounting Screw 1. Locate bottom mounting hole. This hole is near bottom on back panel of heater (see Figure 9). 2. Mark screw location on wall. 3. Remove heater from wall. 4. If installing bottom mounting screw into hollow or solid wall, install wall anchor. Follow steps 1 through 5 under Attaching To Wall Anchor Method, page 7. If installing bottom mounting screw into wall stud, drill hole at marked location using 9/64" drill bit. 5. Replace heater on wall. 6. Insert bottom anchor screw through back panel into bottom anchor or drilled hole (see Figure 9). 7. Tighten screw until heater is firmly secured to wall. Do not over tighten. Note: Do not replace front panel at this time. Replace front panel after making gas connections and checking for leaks (see pages 9-11).

Figure 9 - Installing Bottom Mounting Screw

Keyhole Slots

Page 9 of the Desa Tech CGP11 user manual — WARNING ICON G 001 CAUTION
Page 9 · click to enlarge
Page 9

CONNECTING

NOTICE

TO GAS SUPPLY

A qualified service person must connect heater to gas supply. Follow all local codes.

WARNING ICON G 001 CAUTION

!

Never connect heater directly to the propane supply. This heater requires an external regulator (not supplied). Install the external regulator between the heater and propane supply.

The installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure between 11 and 14 inches of water. If you do not reduce incoming gas pressure, heater regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure 10. Pointing the vent down protects it from freezing rain or sleet.

Figure 10 - External Regulator With Vent Pointing Down

!

Installation must include a manual shutoff valve, ground joint union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 11, page 10). Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves.

!

WARNING ICON G 001 CAUTION

Use pipe joint sealant that is resistant to liquid petroleum (LP) gas.

Install sediment trap in supply line as shown in Figure 11. Locate sediment trap where it is within reach for cleaning. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into heater controls. If sediment trap is not installed or is installed wrong, heater may not run properly.

Show 4 more labels / short text on this page
Propane Supply Tank · External Regulator · Vent Pointing Down · Continued
Page 10 of the Desa Tech CGP11 user manual — PRESSURE TESTING GAS SUPPLY PIPING SYSTEM
Page 10 · click to enlarge
Page 10

3/8" NPT Pipe Nipple

Manual Shutoff Valve *

Reducer Bushing to 1/8" NPT

Test Gauge Connection *

From External Regulator (11" W.C. to 14" W.C. Pressure)

1/8" NPT Plug Tap

Figure 11 - Gas Connection

* An A.G.A. design certified manual shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional A.G.A. design certified manual shutoff valve from your dealer. See ACCESSORY, page 22.

CHECKING

WARNING ICON G 001 WARNING

!

GAS CONNECTIONS

Test all gas piping and connections for leaks after installation or servicing. Correct all leaks at once

!

WARNING ICON G 001 WARNING

Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once.

!

WARNING ICON G 001 CAUTION

Make sure external regulator has been installed between propane supply and heater. See guidelines under CONNECTING TO GAS SUPPLY, page 9.

PRESSURE TESTING GAS SUPPLY PIPING SYSTEM

Test Pressures In Excess Of 1/2 PSIG 1. Disconnect heater and its individual manual shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig will damage heater regulator. 2. Cap off open end of gas pipe where manual shutoff valve was connected. Continued

Show 9 more labels / short text on this page
Pressure Regulator · Heater Cabinet · Ground Joint Union · Tee Joint · Tee Joint · 3" Minimum · Pipe Nipple · Sediment Trap · Cap
Page 11 of the Desa Tech CGP11 user manual — ON POSITION
Page 11 · click to enlarge
Page 11
3. Pressurize supply piping system by either using compressed air or opening propane supply tank valve. 4. Check all joints of gas supply piping system. Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak. 5. Correct all leaks at once.

Test Pressures Equal To or Less Than 1/2 PSIG 1. Close manual shutoff valve (see Figure 12). 2. Pressurize supply piping system by either using compressed air or opening propane supply tank valve. 3. Check all joints from propane supply tank to manual shutoff valve (see Figure 13). Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak. 4. Correct all leaks at once.

PRESSURE TESTING HEATER GAS CONNECTIONS

1. Open manual shutoff valve (see Figure 12). 2. Open propane supply tank valve. 3. Make sure control knob of heater is in the OFF position. 4. Check all joints from manual shutoff valve to control valve (see Figure 13). Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak. 5. Correct all leaks at once. 6. Light heater (see OPERATING HEATER, pages 12 through 15). Check the rest of the internal joints for leaks. 7. Turn off heater (see TO TURN OFF GAS TO APPLIANCE, page 15). 8. Replace front panel.

ON POSITION

OFF POSITION

Figure 12 - Manual Shutoff Valve

Figure 13 - Checking Gas Joints

Show 6 more labels / short text on this page
Open · Manual Shutoff Valve · Closed · Control Valve Location · Propane Supply Tank · Manual Shutoff Valve
Page 12 of the Desa Tech CGP11 user manual — OFF
Page 12 · click to enlarge
Page 12

OPERATING

FOR YOUR SAFETY READ BEFORE LIGHTING

HEATER

!

WARNING ICON G 001 WARNING

If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

A. This appliance has a pilot which must be lighted by hand. When lighting the

pilot, follow these instructions exactly.

B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to

smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

  • Do not try to light any appliance.
  • Do not touch any electric switch; do not use any phone in your building.
  • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
  • If you cannot reach your gas supplier, call the fire department.

C. Use only your hand to push in or turn the gas control knob. Never use tools. If

the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician or gas supplier. Force or attempted repair may result in a fire or explosion.

D. Do not use this appliance if any part has been under water. Immediately call a

qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING INSTRUCTIONS

1. STOP! Read the safety information above.
2. Make sure manual shutoff valve is fully open.
3. Turn control knob clockwise Clockwise to the OFF position.

OFF

PILOT

IGN

LOW

HIGH

Figure 14 - Control Knob In The OFF Position

Control Knob

Page 13 of the Desa Tech CGP11 user manual — OPERATING
Page 13 · click to enlarge
Page 13
4. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you then smell gas, STOP! Follow “B” in the safety information at the top of page 12. If you don’t smell gas, go to the next step.
5. Press in control knob. Note: You may be running this heater for the first time after hooking up to gas supply. If so, the control knob may need to be pressed in for 30 seconds. This will allow air to bleed from the gas system.
  • If control knob does not pop up when released, contact a qualified service person or gas supplier for repairs.
6. Keep control knob pressed in and turn it counterclockwise C-clockwise to the PILOT/IGN position. This will light pilot.

If pilot does not light

  • turn control knob clockwise Clockwise to the OFF position
  • repeat steps 5 and 6 If pilot does not stay lit after several tries
  • refer to TROUBLESHOOTING, pages 17 through 20
  • contact a qualified service person or gas supplier Until repairs are made, light pilot with match. To light pilot with match, see

Figure 15 - Pilot

MANUAL LIGHTING PROCEDURE, page 15.

7. Keep control knob pressed in for 10 seconds after lighting pilot. After 10 seconds, release control knob.

Ignitor Electrode · Pilot Burner Thermocouple

Page 14 of the Desa Tech CGP11 user manual — OFF
Page 14 · click to enlarge
Page 14

TO SELECT HEATING LEVEL

!

WARNING ICON G 001 WARNING

When running heater, set control knob at LOW or HIGH locked positions. Never set control knob between locked positions. Poor combustion and higher levels of carbon monoxide may result.

!

WARNING ICON G 001 CAUTION

Do not try to adjust heating levels by using the manual shutoff valve.

1. Slightly press in control knob and turn counterclockwise C-clockwise to the LOW or HIGH positions. IMPORTANT: Release downward pressure while turning control knob. Control knob will lock at the desired position.

OFF

PILOT

IGN

LOW

OFF

PILOT

IGN

HIGH

OFF

Figure 16 - Burner Patterns

Control · Knob Burners

Page 15 of the Desa Tech CGP11 user manual — GRH/OV 008 BAD PILOT/LP
Page 15 · click to enlarge
Page 15

TO TURN OFF GAS TO APPLIANCE

Shutting Off Heater 1. Turn control knob clockwise Clockwise to the OFF position.

Shutting Off Burner Only (pilot stays lit) 1. Turn control knob clockwise Clockwise to the PILOT position.

MANUAL LIGHTING PROCEDURE

1. Remove front panel (see Figure 8, page 8). 2. Follow steps 1 through 6 under LIGHTING INSTRUCTIONS, pages 12 and 13. 3. With control knob pressed in, strike match. Hold match to pilot until pilot lights. 4. Keep control knob pressed in for 10 seconds after pilot is lit. After 10 seconds, release control knob. 5. Replace front panel.

INSPECTING

Check pilot flame pattern and burner flame pattern often.

BURNER

PILOT FLAME PATTERN Figure 17 shows a correct pilot flame pattern. Figure 18 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool. When the thermocouple cools, the heater will shut down.

GRH/OV 007 GOOD PILOT/LP

Figure 17 - Correct Pilot Flame Pattern

GRH/OV 008 BAD PILOT/LP

Figure 18 - Incorrect Pilot Flame Pattern

If pilot flame pattern is incorrect, as shown in Figure 18

  • turn heater off (see TO TURN OFF GAS TO APPLIANCE, above)
  • see TROUBLESHOOTING, pages 17 through 20
Show 5 more labels / short text on this page
Pilot Burner · Thermocouple · Pilot Burner · Thermocouple · Continued
Page 16 of the Desa Tech CGP11 user manual — TO TURN OFF GAS TO APPLIANCE
Page 16 · click to enlarge
Page 16

BURNER FLAME PATTERN Figure 19 shows a correct burner flame pattern. Figure 20 shows an incorrect burner flame pattern.

Figure 19 - Correct Burner Flame Pattern

Figure 20 - Incorrect Burner Flame Pattern

If burner flame pattern is incorrect, as shown in Figure 20

  • turn heater off (see TO TURN OFF GAS TO APPLIANCE, page 15)
  • see TROUBLESHOOTING, pages 17 through 20
Page 17 of the Desa Tech CGP11 user manual — OBSERVED PROBLEM
Page 17 · click to enlarge
Page 17

CLEANING

!

WARNING ICON G 001 WARNING

AND MAINTENANCE

Turn off heater and let cool before cleaning.

WARNING ICON G 001 CAUTION

!

You must keep control areas, burner, and circulating air passageways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a qualified service person. Heater may need more frequent cleaning due to excessive lint from carpeting, bedding material, etc.

ODS/PILOT AND BURNER ORIFICE

  • Use a vacuum cleaner, pressurized air, or small, soft bristled brush to clean.

CABINET

  • Air Passageways
  • Use a vacuum cleaner or pressurized air to clean. Exterior
  • Use a soft cloth dampened with a mild soap and water mixture. Wipe the cabinet to remove dust.

TROUBLESHOOTING

WARNING ICON G 001 WARNING

!

Turn off heater and let cool before servicing. Only a qualified service person should service and repair heater.

!

WARNING ICON G 001 CAUTION

Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/pilot unit.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

When control knob is pressed in and turned to the PILOT/IGN po- sition, there is no spark at ODS/pilot

1. Ignitor electrode positioned wrong 2. Ignitor electrode broken 3. Ignitor electrode not connected to ignitor cable 4. Ignitor cable pinched or wet
1. Replace ignitor
2. Replace ignitor 3. Reconnect ignitor cable
4. Free ignitor cable if pinched by any metal or tubing. Keep ignitor cable dry 5. Replace ignitor cable 6. Replace control valve (piezo is part of control valve)
5. Broken ignitor cable 6. Bad piezo ignitor
Page 18 of the Desa Tech CGP11 user manual — OBSERVED PROBLEM
Page 18 · click to enlarge
Page 18

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

When control knob is pressed in and turned to the PILOT/IGN po- sition, there is spark at ODS/pilot but no igni- tion

1. Gas supply turned off or manual shutoff valve closed 2. Control knob not pressed in while being turned to PILOT/IGN position 3. Air in gas lines when installed
1. Turn on gas supply or open manual shutoff valve 2. Press in control knob while turning to PILOT/ IGN position
3. Continue holding down control knob. Repeat igniting operation until air is removed 4. Contact local propane gas company 5. Clean ODS/pilot (see C L E A N I N G A N D M A I N T E N A N C E , page 17) or replace ODS/pilot assembly 6. Replace gas regulator
4. Depleted gas supply
5. ODS/pilot is clogged
6. Gas regulator setting is not correct

ODS/pilot lights but flame goes out when control knob is released

1. Control knob not fully pressed in 2. Control knob not pressed in long enough
1. Press in control knob fully 2. After ODS/pilot lights, keep control knob pressed in 10 seconds 3. Fully open manual shutoff valve 4. Hand tighten until snug, then tighten 1/4 turn more 5. A) Contact local propane gas company
3. Manual shutoff valve not fully open 4. Thermocouple connection loose at control valve 5. Pilot flame not touching thermocouple, which allows thermocouple to cool, causing pilot flame to go out. This problem could be caused by one or both of the following: A) Low gas pressure B) Dirty or partially clogged ODS/pilot 6. Thermocouple damaged 7. Control valve damaged

B) Clean ODS/pilot (see C L E A N I N G A N D M A I N T E N A N C E , page 17) or replace ODS/pilot assembly

6. Replace thermocouple
7. Replace control valve

Continued

Page 19 of the Desa Tech CGP11 user manual — OBSERVED PROBLEM
Page 19 · click to enlarge
Page 19

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Burner(s) does not light after ODS/pilot is lit

1. Burner orifice(s) is clogged
1. Clean burner orifice(s) (see CLEANING AND MAINTENANCE, page 17) or replace burner orifice(s) 2. Replace burner orifice(s)
2. Burner orifice(s) diameter is too small 3. Inlet gas pressure is too low
3. Contact local propane gas company

Delayed ignition of burner(s)

1. Manifold pressure is too low 2. Burner orifice(s) is clogged
1. Contact local propane gas company 2. Clean burner orifice(s) (see CLEANING AND MAINTENANCE, page 17) or replace burner orifice(s)

Burner backfiring during combustion

1. Burner orifice(s) is clogged or damaged
1. Clean burner orifice(s) (see CLEANING AND MAINTENANCE, page 17) or replace burner orifice(s) 2. Replace burner 3. Replace gas regulator
2. Burner damaged 3. Gas regulator defective

Burner plaque(s) does not glow

1. Plaque damaged 2. Inlet gas pressure is too low 3. Control knob set between locked positions
1. Replace burner 2. Contact local propane gas company 3. Turn control knob until it locks at desired setting

Slight smoke or odor during initial opera- tion

1. Residues from manufacturing processes
1. Problem will stop after a few hours of operation

Heater produces a clicking/ticking noise just after burner is lit or shut off

1. Metal expanding while heating or contracting while cooling
1. This is common with most heaters. If noise is excessive, contact qualified service person
Page 20 of the Desa Tech CGP11 user manual — SERVICE
Page 20 · click to enlarge
Page 20

WARNING ICON G 001 WARNING

!

If you smell gas

  • Shut off gas supply.
  • Do not try to light any appliance.
  • Do not touch any electrical switch; do not use any phone in your building.
  • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
  • If you cannot reach your gas supplier, call the fire department.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Heater produces un- wanted odors

1. Heater burning vapors from paint, hair spray, glues, etc.
1. Ventilate room. Stop using odor-causing products while heater is running 2. Refill supply tank 3. Locate and correct all leaks (see CHECKING GAS CONNECTIONS, page 10)
2. Low fuel supply 3. Gas leak. See Warning statement at top of page

Heater shuts off in use (ODS operates)

1. Not enough fresh air is available 2. Low line pressure
1. Open window and/or door for ventilation 2. Contact local propane gas company 3. Clean ODS/pilot (see CLEANING AND MAINTENANCE, page 17)
3. ODS/pilot is partially clogged
1. Gas leak. See Warning statement at top of page

Gas odor even when control knob is in OFF position

1. Locate and correct all leaks (see CHECKING GAS CONNECTIONS, page 10) 2. Replace control valve
2. Control valve defective

Gas odor during com- bustion

1. Foreign matter between control valve and burner 2. Gas leak. See Warning statement at top of page
1. Take apart gas tubing and remove foreign matter 2. Locate and correct all leaks (see CHECKING GAS CONNECTIONS, page 10)

You may have further questions about installation, operation, or troubleshooting. If so, contact DESA International’s Technical Service Department at 1-800-323- 5190. TECHNICAL

SERVICE

Page 21 of the Desa Tech CGP11 user manual — PARTS
Page 21 · click to enlarge
Page 21

SPECIFICATIONS

B.T.U. (Variable) 5,500/11,000 Type Gas Propane Only Ignition Piezo Pressure Regulator Setting 8" W.C. Inlet Gas Pressure (inches of water)

Maximum 14" Minimum 11" Dimensions, Inches (H x W x D)

Heater 20 1/2 x 13 1/2 x 5 Carton 25 x 16 11/16 x 7 1/2 Weight (pounds)

Heater 14 Shipping 17

SERVICE

When gas pressure is too low

  • pilot will not stay lit
  • burner(s) will have delayed ignition
  • heater will not produce specified heat
  • propane gas supply may be low When gas quality is bad

HINTS

  • pilot will not stay lit
  • burner(s) will produce flames and soot
  • heater will backfire when lit

You may feel your gas pressure is too low or gas quality is bad. If so, contact your local propane gas supplier.

REPLACEMENT

PARTS

Parts Under Warranty Contact authorized dealer from whom you purchased this product. If they cannot supply original replacement part(s), call DESA International’s Technical Service Department at 1-800-972-7879 for referral information.

When contacting your dealer or DESA International, have ready:

  • your name
  • your address
  • model number of your heater
  • how heater was malfunctioning
  • type of gas used (propane or natural gas)
  • purchase date Usually, we will ask you to return the defective part to the factory.

Parts Not Under Warranty Contact authorized dealers of this product. If they cannot supply original replace- ment part(s), call DESA International’s Parts Department at (502) 781-9600.

When calling DESA International, have ready:

  • model number of your heater
  • the replacement part number
Page 22 of the Desa Tech CGP11 user manual — SERVICE PUBLICATIONS
Page 22 · click to enlarge
Page 22

PARTS CENTRALS

These Parts Centrals are privately owned businesses. They have agreed to support our customer’s needs by providing original replacement parts and accessories.

Portable Heater Parts 342 N. County Rd. 400 East Valparaiso, IN 46383 All States 219-462-7441 1-800-362-6951

Tarantin Tank Co. P.O. Box 6129 Freehold, NJ 07728 908-780-9340

Cans Unlimited, Inc. P.O. Box 645 Taylor, SC 29687 All States 803-879-3009 1-800-845-5301

Albany Ladder 1586-90 Central Avenue Albany, NY 12205 NY, MA, VT 518-869-5335 1-800-354-7368

Master Service Center 1184 Wilson NW Walker, MI 49504 616-791-4760 1-800-446-1446

Dealers LP P.O. Box 341145 Bartlett, TN 38184 AL, TN 901-386-8780 1-800-428-8902

Dayton Hardware P.O. Box 275 North Dayton Station Dayton, OH 45404 All States 513-258-3721 OH 1-800-762-3426

Washer Equipment Co. 1715 Main Street Kansas City, MO 64108 KS, MO, AR 816-842-3911

East Coast Energy Products 707 Broadway W. Long Branch, NJ 07764 908-870-8809 1-800-755-8809

Warmer Image Halco Enterprises 208 Carter Drive, Unit 21 West Chester, PA 19382 215-696-2670 1-800-368-0803

SERVICE PUBLICATIONS

You can purchase a service manual from the address listed on the back page of this manual. Send a check for $5.00 payable to DESA International.

ACCESSORY Purchase this heater accessory from your local dealer. If they cannot supply this accessory, either contact your nearest Parts Central (see above) or call DESA International’s Parts Department at 1-800-972-7879. You can also write to the address listed on the back page of this manual.

MANUAL SHUTOFF VALVE - GA5010 Manual shutoff valve with 1/8" NPT tap.

Page 23 of the Desa Tech CGP11 user manual — HEATER EXPLODED VIEW
Page 23 · click to enlarge
Page 23

PARTS LIST This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under REPLACEMENT PARTS on page 21 of this manual.

KEY PART NO. NUMBER DESCRIPTION QTY.

KEY PART NO. NUMBER DESCRIPTION QTY.

1 098304-01 Screw, #10 x 3/8" 2 2 099467-02 Front Panel Assembly 1 3 099318-01 Grill Guard 1 4 098342-01 Grill Guard Clip 2 5 099469-02 Reflector Assembly 1 6 M15823-37 Screw Hex #8 x 1/4" 10 7 099059-03 ODS/Pilot Assembly 1 7-1 098514-01 Thermocouple 1 7-2 098594-01 Ignitor Electrode 1 8 099398-02 Burner Assembly 1 9 099056-01 Injector 2 10 099390-02 Tubing - Valve to plaque A 1 11 099387-05 Pilot Tubing - Valve to pilot 1 12 099392-01 Tubing - Valve to plaque B 1

13 099391-01 Tubing - Regulator to valve 1 14 099385-01 Control Valve 1 15 099057-01 Pressure Tap Fitting 1 16 098276-01 1/8 Pipe Plug 1 17 099468-02 Cabinet Assembly 1 18 099415-02 Gas Regulator 1 19 098303-02 Screw, #6 x 5/16" 2 20 098508-01 Valve Retainer Nut 1 21 099393-01 Control Knob 1 22 M11084-26 Screw, #10 x 3/8" 2 23 099818-01 Internal Tooth Washer 1

PARTS AVAILABLE - NOT SHOWN

099395-02 Control Position Label 1

ILLUSTRATED

PARTS BREAKDOWN

HEATER EXPLODED VIEW

A B

ODS/PILOT

7-2 7-1

Page 24 of the Desa Tech CGP11 user manual — 099401-01 REV. E 9/92
Page 24 · click to enlarge
Page 24

KEEP THIS WARRANTY WARRANTY INFORMATION

Serial No.

Always specify model and serial numbers when communicating with the factory.

We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied.

LIMITED WARRANTY COMFORT GLOW VENT-FREE RESIDENTIAL GAS HEATERS

DESA International warrants this product to be free from defects in materials and components for one (1) year from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions. To make a claim under this warranty the Bill of Sale or cancelled check must be presented.

This warranty is extended only to the original retail purchaser. This warranty covers only the cost of part(s) required to restore this heater to proper operating condition. Warranty part(s) MUST be obtained through authorized dealers of this product and/ or DESA International who will provide original factory replacement parts. Failure to use original factory replacement parts voids this warranty. The heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit.

This warranty does not apply to parts that are not in original condition because of normal wear and tear, or parts that fail or become damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation. Travel, diagnostic cost, labor, transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner.

TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MER- CHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO ONE (1) YEAR FROM THE DATE OF FIRST PURCHASE; AND DESA INTERNATIONAL’S LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND DESA INTERNATIONAL SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSO- EVER INCLUDING INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES.

Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or consequential damages, so the above limitation on implied warranties, or exclusion or limitation on damages may not apply to you.

This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.

DESA

For information about this warranty write:

INTERNATIONAL P.O. Box 90004 2701 Industrial Drive Bowling Green, KY 42102-9004

099401-01 REV. E 9/92

Model · Date Purchased

Fix-it

Troubleshooting

Common problems, likely causes, and what to do.

ProblemPossible causeRemedy
2 p.2
2 p.2
18 p.18
18 p.18
20 p.20
20 p.20

Ask about the Desa Tech CGP11

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Desa Tech CGP11

Be the first to ask — other owners or our team will answer.

Original document

Desa Tech CGP11 manual PDF

24 pages·215 KB·Gas Heater·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…