OWNER’S OPERATION AND INSTALLATION MANUAL
Model: CGP11
flammable vapors and liquids in the vicinity of this or any other appliance.
E
S
G
N
E
R
A
M
A
N
G S A
A
S
O
N
— Installation and service must be per-
S
O
A
T
formed by a qualified installer, service agency, or the gas supplier.
E
R
T
F
I E
Save this manual for future reference.
® · ®


!

Figure 1 - Vent-Free Propane Gas Heater
LOCAL CODES Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of the National Gas Code ANSI Z223.1, also known as NFPA 54*.
*Available from: American National Standards Institute, Inc.
1430 Broadway New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park Quincy, MA 02269
UNPACKING 1. Remove heater from carton. 2. Remove all protective packaging applied to heater for shipment. 3. Check heater for any shipping damage. If heater is damaged, promptly inform dealer where you bought heater.
Safety Device This heater has a pilot with an Oxygen Depletion Sensor Shutoff System (ODS). The ODS/pilot is a required feature for vent-free room heaters. The ODS/pilot shuts off the heater if there is not enough fresh air.
Piezo Ignition System This heater has a piezo ignitor. This system requires no matches, batteries, or other sources to light heater.

TO WALL
A qualified service person must install heater. Follow all local codes.
CHECK GAS TYPE Use only propane gas. If your gas supply is not propane, do not install heater. Call dealer where you bought heater for proper type heater.
INSTALLATION ITEMS Before installing heater, make sure you have the items below:
* An A.G.A. design-certified manual shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. The optional A.G.A. design-certified manual shutoff valve can be purchased from your dealer. See ACCESSORY, page 22.
LOCATING HEATER This heater is designed to be mounted on a wall.
Maintain the minimum clearances shown in Figure 2 (page 6). If you can, provide greater clearances from floor, ceiling, and joining wall.
!
Never install the heater
Operating heater where impurities in the air (such as tobacco smoke) exist, may discolor walls.
Continued

For convenience and efficiency, install heater
8" Minimum From Sides Of Heater
Right Side Left Side
Minimum To Top Surface Of Carpeting, Tile Or Other Combustible Material
Figure 2 - Mounting Clearances As Viewed From Front of Heater
INSTALLING HEATER TO WALL Marking Screw Locations 1. Determine where you will locate heater.
10 7/8" Minimum To
20 1/4" Minimum To
Figure 3 - Mounting Screw Locations

Installing Two Mounting Screws Note: Wall anchors and mounting screws are in hardware package. The hardware package is provided with heater.
Attaching to wall stud method For attaching mounting screw to wall stud 1. Drill hole at marked location using 9/64" drill bit. 2. Insert mounting screw into wall stud. 3. Tighten screw until 1/16" space (thickness of penny) is between screwhead and wall.
Attaching to wall anchor method Follow instructions below to attach mounting screws to hollow walls (wall areas between studs) or solid walls (concrete or masonry). 1. Drill holes at marked locations using 5/16" drill bit. For solid walls (concrete or masonry), drill at least 1 1/4" deep. 2. Fold wall anchor (see Figure 4).
Figure 4 - Folding Anchor
Thin Walls (1/4" to 1/2" thick)
Figure 5 - Popping Open Anchor Wings For Thin Walls
Thin or Thick Wall (thick wall shown)
ANCHOR Figure 6 - Tightening Anchors
1/16" Space · Solid Wall

Placing Heater On Mounting Screws 1. Locate two keyhole slots on back panel of heater (see Figure 7). 2. Place large openings of slots over screwheads. Slide heater down until screws are in small portion of slots.
Figure 7 - Location Of Keyhole Slots On Back Panel Of Heater
Removing Front Panel Of Heater 1. Remove two screws near bottom corners of front panel. 2. Lift straight up on grill guard until it stops. Grill guard will slide up about 1/4". 3. Pull bottom of front panel forward, then down.
Figure 8 - Removing Front Panel Of Heater
Installing Bottom Mounting Screw 1. Locate bottom mounting hole. This hole is near bottom on back panel of heater (see Figure 9). 2. Mark screw location on wall. 3. Remove heater from wall. 4. If installing bottom mounting screw into hollow or solid wall, install wall anchor. Follow steps 1 through 5 under Attaching To Wall Anchor Method, page 7. If installing bottom mounting screw into wall stud, drill hole at marked location using 9/64" drill bit. 5. Replace heater on wall. 6. Insert bottom anchor screw through back panel into bottom anchor or drilled hole (see Figure 9). 7. Tighten screw until heater is firmly secured to wall. Do not over tighten. Note: Do not replace front panel at this time. Replace front panel after making gas connections and checking for leaks (see pages 9-11).
Figure 9 - Installing Bottom Mounting Screw
Keyhole Slots

TO GAS SUPPLY
A qualified service person must connect heater to gas supply. Follow all local codes.
!
Never connect heater directly to the propane supply. This heater requires an external regulator (not supplied). Install the external regulator between the heater and propane supply.
The installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure between 11 and 14 inches of water. If you do not reduce incoming gas pressure, heater regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure 10. Pointing the vent down protects it from freezing rain or sleet.
Figure 10 - External Regulator With Vent Pointing Down
Installation must include a manual shutoff valve, ground joint union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 11, page 10). Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves.
Use pipe joint sealant that is resistant to liquid petroleum (LP) gas.
Install sediment trap in supply line as shown in Figure 11. Locate sediment trap where it is within reach for cleaning. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into heater controls. If sediment trap is not installed or is installed wrong, heater may not run properly.

3/8" NPT Pipe Nipple
Manual Shutoff Valve *
Reducer Bushing to 1/8" NPT
Test Gauge Connection *
From External Regulator (11" W.C. to 14" W.C. Pressure)
1/8" NPT Plug Tap
Figure 11 - Gas Connection
* An A.G.A. design certified manual shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional A.G.A. design certified manual shutoff valve from your dealer. See ACCESSORY, page 22.
!
GAS CONNECTIONS
Test all gas piping and connections for leaks after installation or servicing. Correct all leaks at once
Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once.
Make sure external regulator has been installed between propane supply and heater. See guidelines under CONNECTING TO GAS SUPPLY, page 9.
Test Pressures In Excess Of 1/2 PSIG 1. Disconnect heater and its individual manual shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig will damage heater regulator. 2. Cap off open end of gas pipe where manual shutoff valve was connected. Continued

Test Pressures Equal To or Less Than 1/2 PSIG 1. Close manual shutoff valve (see Figure 12). 2. Pressurize supply piping system by either using compressed air or opening propane supply tank valve. 3. Check all joints from propane supply tank to manual shutoff valve (see Figure 13). Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak. 4. Correct all leaks at once.
1. Open manual shutoff valve (see Figure 12). 2. Open propane supply tank valve. 3. Make sure control knob of heater is in the OFF position. 4. Check all joints from manual shutoff valve to control valve (see Figure 13). Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak. 5. Correct all leaks at once. 6. Light heater (see OPERATING HEATER, pages 12 through 15). Check the rest of the internal joints for leaks. 7. Turn off heater (see TO TURN OFF GAS TO APPLIANCE, page 15). 8. Replace front panel.
OFF POSITION
Figure 12 - Manual Shutoff Valve
Figure 13 - Checking Gas Joints

HEATER
!
WARNING ICON G 001 WARNING
If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
A. This appliance has a pilot which must be lighted by hand. When lighting the
pilot, follow these instructions exactly.
B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to
smell next to the floor because some gas is heavier than air and will settle on the floor.
C. Use only your hand to push in or turn the gas control knob. Never use tools. If
the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician or gas supplier. Force or attempted repair may result in a fire or explosion.
D. Do not use this appliance if any part has been under water. Immediately call a
qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
PILOT
IGN
LOW
HIGH
Figure 14 - Control Knob In The OFF Position
Control Knob

If pilot does not light
Figure 15 - Pilot
MANUAL LIGHTING PROCEDURE, page 15.
Ignitor Electrode · Pilot Burner Thermocouple

!
WARNING ICON G 001 WARNING
When running heater, set control knob at LOW or HIGH locked positions. Never set control knob between locked positions. Poor combustion and higher levels of carbon monoxide may result.
Do not try to adjust heating levels by using the manual shutoff valve.
PILOT
IGN
LOW
OFF
PILOT
IGN
HIGH
OFF
Figure 16 - Burner Patterns
Control · Knob Burners

Shutting Off Heater 1. Turn control knob clockwise Clockwise to the OFF position.
Shutting Off Burner Only (pilot stays lit) 1. Turn control knob clockwise Clockwise to the PILOT position.
Check pilot flame pattern and burner flame pattern often.
PILOT FLAME PATTERN Figure 17 shows a correct pilot flame pattern. Figure 18 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool. When the thermocouple cools, the heater will shut down.
Figure 17 - Correct Pilot Flame Pattern
Figure 18 - Incorrect Pilot Flame Pattern
If pilot flame pattern is incorrect, as shown in Figure 18

BURNER FLAME PATTERN Figure 19 shows a correct burner flame pattern. Figure 20 shows an incorrect burner flame pattern.
Figure 19 - Correct Burner Flame Pattern
Figure 20 - Incorrect Burner Flame Pattern
If burner flame pattern is incorrect, as shown in Figure 20

!
AND MAINTENANCE
Turn off heater and let cool before cleaning.
!
You must keep control areas, burner, and circulating air passageways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a qualified service person. Heater may need more frequent cleaning due to excessive lint from carpeting, bedding material, etc.
!
Turn off heater and let cool before servicing. Only a qualified service person should service and repair heater.
Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/pilot unit.
POSSIBLE CAUSE
REMEDY
When control knob is pressed in and turned to the PILOT/IGN po- sition, there is no spark at ODS/pilot

POSSIBLE CAUSE
REMEDY
When control knob is pressed in and turned to the PILOT/IGN po- sition, there is spark at ODS/pilot but no igni- tion
ODS/pilot lights but flame goes out when control knob is released
B) Clean ODS/pilot (see C L E A N I N G A N D M A I N T E N A N C E , page 17) or replace ODS/pilot assembly
Continued

POSSIBLE CAUSE
REMEDY
Burner(s) does not light after ODS/pilot is lit
Delayed ignition of burner(s)
Burner backfiring during combustion
Burner plaque(s) does not glow
Slight smoke or odor during initial opera- tion
Heater produces a clicking/ticking noise just after burner is lit or shut off

!
If you smell gas
POSSIBLE CAUSE
REMEDY
Heater produces un- wanted odors
Heater shuts off in use (ODS operates)
Gas odor even when control knob is in OFF position
Gas odor during com- bustion
You may have further questions about installation, operation, or troubleshooting. If so, contact DESA International’s Technical Service Department at 1-800-323- 5190. TECHNICAL

B.T.U. (Variable) 5,500/11,000 Type Gas Propane Only Ignition Piezo Pressure Regulator Setting 8" W.C. Inlet Gas Pressure (inches of water)
Maximum 14" Minimum 11" Dimensions, Inches (H x W x D)
Heater 20 1/2 x 13 1/2 x 5 Carton 25 x 16 11/16 x 7 1/2 Weight (pounds)
Heater 14 Shipping 17
When gas pressure is too low
You may feel your gas pressure is too low or gas quality is bad. If so, contact your local propane gas supplier.
Parts Under Warranty Contact authorized dealer from whom you purchased this product. If they cannot supply original replacement part(s), call DESA International’s Technical Service Department at 1-800-972-7879 for referral information.
When contacting your dealer or DESA International, have ready:
Parts Not Under Warranty Contact authorized dealers of this product. If they cannot supply original replace- ment part(s), call DESA International’s Parts Department at (502) 781-9600.
When calling DESA International, have ready:

These Parts Centrals are privately owned businesses. They have agreed to support our customer’s needs by providing original replacement parts and accessories.
Portable Heater Parts 342 N. County Rd. 400 East Valparaiso, IN 46383 All States 219-462-7441 1-800-362-6951
Tarantin Tank Co. P.O. Box 6129 Freehold, NJ 07728 908-780-9340
Cans Unlimited, Inc. P.O. Box 645 Taylor, SC 29687 All States 803-879-3009 1-800-845-5301
Albany Ladder 1586-90 Central Avenue Albany, NY 12205 NY, MA, VT 518-869-5335 1-800-354-7368
Master Service Center 1184 Wilson NW Walker, MI 49504 616-791-4760 1-800-446-1446
Dealers LP P.O. Box 341145 Bartlett, TN 38184 AL, TN 901-386-8780 1-800-428-8902
Dayton Hardware P.O. Box 275 North Dayton Station Dayton, OH 45404 All States 513-258-3721 OH 1-800-762-3426
Washer Equipment Co. 1715 Main Street Kansas City, MO 64108 KS, MO, AR 816-842-3911
East Coast Energy Products 707 Broadway W. Long Branch, NJ 07764 908-870-8809 1-800-755-8809
Warmer Image Halco Enterprises 208 Carter Drive, Unit 21 West Chester, PA 19382 215-696-2670 1-800-368-0803
You can purchase a service manual from the address listed on the back page of this manual. Send a check for $5.00 payable to DESA International.
ACCESSORY Purchase this heater accessory from your local dealer. If they cannot supply this accessory, either contact your nearest Parts Central (see above) or call DESA International’s Parts Department at 1-800-972-7879. You can also write to the address listed on the back page of this manual.
MANUAL SHUTOFF VALVE - GA5010 Manual shutoff valve with 1/8" NPT tap.

PARTS LIST This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under REPLACEMENT PARTS on page 21 of this manual.
KEY PART NO. NUMBER DESCRIPTION QTY.
KEY PART NO. NUMBER DESCRIPTION QTY.
1 098304-01 Screw, #10 x 3/8" 2 2 099467-02 Front Panel Assembly 1 3 099318-01 Grill Guard 1 4 098342-01 Grill Guard Clip 2 5 099469-02 Reflector Assembly 1 6 M15823-37 Screw Hex #8 x 1/4" 10 7 099059-03 ODS/Pilot Assembly 1 7-1 098514-01 Thermocouple 1 7-2 098594-01 Ignitor Electrode 1 8 099398-02 Burner Assembly 1 9 099056-01 Injector 2 10 099390-02 Tubing - Valve to plaque A 1 11 099387-05 Pilot Tubing - Valve to pilot 1 12 099392-01 Tubing - Valve to plaque B 1
13 099391-01 Tubing - Regulator to valve 1 14 099385-01 Control Valve 1 15 099057-01 Pressure Tap Fitting 1 16 098276-01 1/8 Pipe Plug 1 17 099468-02 Cabinet Assembly 1 18 099415-02 Gas Regulator 1 19 098303-02 Screw, #6 x 5/16" 2 20 098508-01 Valve Retainer Nut 1 21 099393-01 Control Knob 1 22 M11084-26 Screw, #10 x 3/8" 2 23 099818-01 Internal Tooth Washer 1
099395-02 Control Position Label 1
PARTS BREAKDOWN
A B
ODS/PILOT
7-2 7-1

Serial No.
Always specify model and serial numbers when communicating with the factory.
We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied.
DESA International warrants this product to be free from defects in materials and components for one (1) year from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions. To make a claim under this warranty the Bill of Sale or cancelled check must be presented.
This warranty is extended only to the original retail purchaser. This warranty covers only the cost of part(s) required to restore this heater to proper operating condition. Warranty part(s) MUST be obtained through authorized dealers of this product and/ or DESA International who will provide original factory replacement parts. Failure to use original factory replacement parts voids this warranty. The heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit.
This warranty does not apply to parts that are not in original condition because of normal wear and tear, or parts that fail or become damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation. Travel, diagnostic cost, labor, transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner.
TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MER- CHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO ONE (1) YEAR FROM THE DATE OF FIRST PURCHASE; AND DESA INTERNATIONAL’S LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND DESA INTERNATIONAL SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSO- EVER INCLUDING INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES.
Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or consequential damages, so the above limitation on implied warranties, or exclusion or limitation on damages may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.
For information about this warranty write:
INTERNATIONAL P.O. Box 90004 2701 Industrial Drive Bowling Green, KY 42102-9004
Model · Date Purchased
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.