Model: CGP10
— Do not store or use gasoline or other flammable vapors and liquids in the
vicinity of this or any other appliance.
agency, or the gas supplier.
Save this manual for future reference.
®



Figure 1 - Vent-Free Propane Gas Heater
LOCAL CODES Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANSI Z223.1, also known as NFPA 54*.
*Available from: American National Standards Institute, Inc.
1430 Broadway New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park Quincy, MA 02269
UNPACKING 1. Remove heater from carton. 2. Remove all protective packaging applied to heater for shipment. 3. Check heater for any shipping damage. If heater is damaged, promptly inform dealer where you bought heater.
Safety Device This heater has a pilot with an Oxygen Depletion Sensor Shutoff System (ODS). The ODS/pilot is a required feature for vent-free room heaters. The ODS/pilot shuts off the heater if there is not enough fresh air.
Piezo Ignition System This heater has a piezo ignitor. This system requires no matches, batteries, or other sources to light heater.

FOR COMBUSTION
This heater must have fresh air for proper operation. If not, poor fuel combustion could result. Read the following instructions to insure proper fresh air for this and other fuel-burning appliances in your home.
Today’s homes are built more energy efficient than ever. New materials, increased insulation, and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in. During heating months, home owners want their homes as airtight as possible.
While it is good to make your home energy efficient, your home needs to breathe. Fresh air must enter your home. All fuel-burning appliances need fresh air for proper combustion and ventilation.
Exhaust fans, fireplaces, clothes dryers, and fuel burning appliances draw air from the house to operate. You must provide adequate fresh air for these appliances. This will insure proper venting of vented fuel-burning appliances.
PRODUCING ADEQUATE VENTILATION All spaces in homes fall into one of the three following ventilation classifications: 1. Unusually Tight Contruction; 2. Unconfined Space; 3. Confined Space. The information on pages 5 through 8 will help you classify your space and provide adequate ventilation.
Unusually Tight Construction The air that leaks around doors and windows may provide enough fresh air for combustion and ventilation. However, in buildings of unusually tight construction, you must provide additional fresh air.
Unusually tight construction is defined as construction where: a. walls and ceilings exposed to the outside atmosphere have a continu-
ous water vapor retarder with a rating of one perm or less with open- ings gasketed or sealed and b. weather stripping has been added on openable windows and doors and c. caulking or sealants are applied to areas such as joints around window
and door frames, between sole plates and floors, between wall-ceiling joints, between wall panels, at penetrations for plumbing, electrical, and gas lines, and at other openings.
If your home meets all of the three criteria above, you must provide addi- tional fresh air. See Ventilation Air From Outdoors, page 8.
If your home does not meet all of the three criteria above, continue reading. Unconfined Space An unconfined space has a minimum air volume of 50 cubic feet for each 1000 BTU/Hr input rating of all appliances in the space (cubic feet equals length x width x height of space). Include adjoining rooms only if there are doorless passageways or ventilation grills between the rooms.
Confined Space A confined space has an air volume of less than 50 cubic feet for each 1000 BTU/Hr input rating of all appliances in the space (cubic feet equals length x width x height of space). Include adjoining rooms only if there are doorless passageways or ventilation grills between the rooms. Continued

FOR COMBUSTION
Determining if You Have a Confined or Unconfined Space Use this worksheet to determine if you have a confined or unconfined space.
Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms.
Length x Width x Height = cu. ft. (volume of space) Example: Space size 18 ft. (length) x 16 ft. (width) x 8 ft. (ceiling height) = 2304 cu. ft. (volume of space)
If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these rooms to the total volume of the space.
(volume of space) ÷ 50 cu. ft. = (Maximum BTU/Hr the space can support)
Example: 2304 cu. ft. (volume of space) ÷ 50 cu. ft. = 46.1 or 46,100 (maximum BTU/Hr the space can support)
Vent-free heater BTU/Hr Gas water heater* BTU/Hr Gas furnace BTU/Hr Vented gas heater BTU/Hr Gas fireplace logs BTU/Hr Other gas appliances* + BTU/Hr Total = BTU/Hr
Example: Gas water heater 40,000 BTU/Hr Vent-free heater + 10,000 BTU/Hr Total = 50,000 BTU/Hr * Do not include direct-vent gas appliances. Direct-vent draws combustion air from the outdoors and vents to the outdoors.
BTU/Hr (maximum the space can support) BTU/Hr (actual amount of BTU/Hr used)
The space in the above example is a confined space because the actual BTU/Hr used is more than the maximum BTU/Hr the space can support. You must provide additional fresh air. Your options are as follows:
A. Rework worksheet, adding the space of an adjoining room. If the extra space provides
an unconfined space, remove door to adjoining room or add ventilation grills between rooms. See Ventilation Air From Inside Building, page 7. B. Vent room directly to the outdoors. See Ventilation Air From Outdoors, page 8. C. Install a lower BTU/Hr heater, if lower BTU/Hr size makes room unconfined.
If the actual BTU/Hr used is less than the maximum BTU/Hr the space can support, the space is an unconfined space. You will need no additional fresh air ventilation.

FOR COMBUSTION
Ventilation Air From Inside Building This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 2). You can also remove door into adjoining room (see option 3, Figure 2).
Ventilation Grills Into Adjoining Room,
Or Remove Door into Adjoining
Figure 2 - Ventilation Air from Inside Building

FOR COMBUSTION
Ventilation Air From Outdoors
Provide extra fresh air by using ventilation grills or ducts. You must provide two perma- nent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces. Follow the National Fuel Gas Code NFPA 54/ANSI Z223.1, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.
Inlet Air Ventilated Crawl Space
Figure 3 - Ventilation Air from Outdoors

CHECK GAS TYPE Use only propane gas. If your gas supply is not propane, do not install heater. Call dealer where you bought heater for proper type heater. INSTALLATION ITEMS Before installing heater, make sure you have the items listed below.

For convenience and efficiency, install heater
6" Minimum From Sides Of Heater
Right Side Left Side
Minimum To Top Surface Of Carpeting, Tile Or Other Combustible Material
Figure 4 - Mounting Clearances As Viewed From Front of Heater
INSTALLING HEATER TO WALL Marking Screw Locations 1. Determine where you will locate heater.
8 7/8" Minimum To
20 1/4" Minimum To
Figure 5 - Mounting Screw Locations

Installing Two Mounting Screws Note: Wall anchors and mounting screws are in hardware package. The hardware package is provided with heater.
Attaching to wall stud method For attaching mounting screw to wall stud 1. Drill hole at marked location using 9/64" drill bit. 2. Insert mounting screw into wall stud. 3. Tighten screw until 1/16" space (thickness of penny) is between screwhead and wall.
Attaching to wall anchor method Follow instructions below to attach mounting screws to hollow walls (wall areas between studs) or solid walls (concrete or masonry). 1. Drill holes at marked locations using 5/16" drill bit. For solid walls (concrete or masonry), drill at least 1 1/4" deep. 2. Fold wall anchor (see Figure 6).
Figure 6 - Folding Anchor
Thin Walls (1/4" to 1/2" thick)
Figure 7 - Popping Open Anchor Wings For Thin Walls
Thin or Thick Wall (thick wall shown)
Figure 8 - Tightening Anchors
1/16" Space · Solid Wall

Placing Heater On Mounting Screws 1. Locate two keyhole slots on back panel of heater (see Figure 9). 2. Place large openings of slots over screwheads. Slide heater down until screws are in small portion of slots.
Figure 9 - Location Of Keyhole Slots On Back Panel Of Heater
Removing Front Panel Of Heater 1. Remove two screws near bottom corners of front panel. 2. Lift straight up on grill guard until it stops. Grill guard will slide up about 1/4". 3. Pull bottom of front panel forward, then down.
Figure 10 - Removing Front Panel Of Heater Installing Bottom Mounting Screw 1. Locate bottom mounting hole. This hole is near bottom on back panel of heater (see Figure 11). 2. Mark screw location on wall. 3. Remove heater from wall. 4. If installing bottom mounting screw into hollow or solid wall, install wall anchor. Follow steps 1 through 5 under Attaching To Wall Anchor Method, page 11. If installing bottom mounting screw into wall stud, drill hole at marked location using 9/64" drill bit. 5. Replace heater on wall. 6. Insert bottom anchor screw through back panel into bottom anchor or drilled hole (see Figure 11). 7. Tighten screw until heater is firmly secured to wall. Do not over tighten. Note: Do not replace front panel at this time. Replace front panel after making gas connections and checking for leaks (see pages 13-15).
Figure 11 - Installing Bottom Mounting Screw
Keyhole Slots

The installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure between 11 and 14 inches of water. If you do not reduce incoming gas pressure, heater regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure 12. Pointing the vent down protects it from freezing rain or sleet.
Figure 12 - External Regulator With Vent Pointing Down
Installation must include a manual shutoff valve, ground joint union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 13, page 14).
Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves.
Install sediment trap in supply line as shown in Figure 13, page 14. Locate sediment trap where it is within reach for cleaning. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into heater controls. If sediment trap is not installed or is installed wrong, heater may not run properly.
Propane Supply Tank · External Regulator · Vent Pointing Down

3/8" NPT Pipe Nipple
Manual Shutoff Valve * From External Regulator (11" W.C. to 14" W.C. Pressure)
Reducer Bushing to 1/8" NPT
Test Gauge Connection *
1/8" NPT Plug Tap
Figure 13 - Gas Connection
* An A.G.A. design certified manual shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional A.G.A. design certified manual shutoff valve from your dealer. See Accessory, page 25.
Test Pressures In Excess Of 1/2 PSIG 1. Disconnect heater and its individual manual shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig will damage heater regulator. 2. Cap off open end of gas pipe where manual shutoff valve was connected.

Test Pressures Equal To or Less Than 1/2 PSIG 1. Close manual shutoff valve (see Figure 14). 2. Pressurize supply piping system by either using compressed air or opening propane supply tank valve. 3. Check all joints from propane supply tank to manual shutoff valve (see Figure 15). Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak. 4. Correct all leaks at once.
1. Open manual shutoff valve (see Figure 14). 2. Open propane supply tank valve. 3. Make sure control knob of heater is in the OFF position. 4. Check all joints from manual shutoff valve to control valve (see Figure 15). Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak. 5. Correct all leaks at once. 6. Light heater (see Operating Heater, pages 16 through 18). Check all other internal joints for leaks. 7. Turn off heater (see To Turn Off Gas To Appliance, page 18). 8. Replace front panel.
OFF POSITION
Figure 14 - Manual Shutoff Valve
Figure 15 - Checking Gas Joints

HEATER
A. This appliance has a pilot which must be lighted by hand. When lighting
the pilot, follow these instructions exactly.
B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure
to smell next to the floor because some gas is heavier than air and will settle on the floor.
C. Use only your hand to push in or turn the gas control knob. Never use
tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician or gas supplier. Force or attempted repair may result in a fire or explosion.
D. Do not use this appliance if any part has been under water. Immediately
call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
Ignitor Button Control Knob
OFF
HIGH
IGNITOR
LOW
Figure 16 - Control Knob In The OFF Position

Figure 17 - Pilot
Ignitor Electrode · Thermocouple Pilot Burner

HEATER
Shutting Off Burner Only (pilot stays lit) 1. Turn control knob clockwise Clockwise to the PILOT position.
Check pilot flame pattern and burner flame pattern often.
Figure 18 shows a correct pilot flame pattern. Figure 19 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool. When the thermocouple cools, the heater will shut down.
Figure 18 - Correct Pilot Flame Pattern
Figure 19 - Incorrect Pilot Flame Pattern
If pilot flame pattern is incorrect, as shown in Figure 19

BURNER
Figure 20 shows a correct burner flame pattern. Figure 21 shows an incorrect burner flame pattern. The incorrect burner flame pattern shows yellow tipping of the flame. It also shows the flame higher than 1/2 the glass panel height.
CORRECT FLAME PATTERN
AT HIGH POSITION
Figure 20 - Correct Burner Flame Pattern
INCORRECT FLAME PATTERN
AT HIGH POSITION
Figure 21 - Incorrect Burner Flame Pattern
If burner flame pattern is incorrect, as shown in Figure 21
Yellow Tipping

operation.
OBSERVED PROBLEM
REMEDY
When ignitor button is pressed, there is no spark at ODS/pilot

POSSIBLE CAUSE
REMEDY
When ignitor button is pressed, there is spark at ODS/pilot but no ignition
ODS/pilot lights but flame goes out when control knob is re- leased
B) Clean ODS/pilot (see Cleaning and Maintenance, page 20) or replace ODS/pilot assembly

POSSIBLE CAUSE
REMEDY
Burner does not light after ODS/pilot is lit
Delayed ignition of burner
Burner backfiring dur- ing combustion
Yellow flame during burner combustion
Slight smoke or odor during initial opera- tion
Heater produces a whistling noise when burner is lit

If you smell gas
POSSIBLE CAUSE
REMEDY
Heater produces a clicking/ticking noise just after burner is lit or shut off
Heater produces un- wanted odors
Heater shuts off in use (ODS operates)
Gas odor even when control knob is in OFF position
Gas odor during com- bustion

You may have further questions about installation, operation, or troubleshooting. If so, contact DESA International’s Technical Service Department at 1-800-323- 5190. TECHNICAL
SPECIFICATIONS BTU (Variable) 5,000/10,000 Type Gas Propane Only Ignition Piezo Pressure Regulator Setting 8" W.C. Inlet Gas Pressure (inches of water)
Maximum 14" Minimum 11" Dimensions, Inches (H x W x D)
Heater 20 1/2 x 13 1/2 x 5 Carton 25 x 16 11/16 x 7 1/2 Weight (pounds)
Heater 13.5 Shipping 16.5
When gas pressure is too low
You may feel your gas pressure is too low or gas quality is bad. If so, contact your local propane gas supplier.
Parts Under Warranty Contact authorized dealer from whom you purchased this product. If they cannot supply original replacement part(s), call DESA International’s Technical Service Department at 1-800-323-5190 for referral information.
When contacting your dealer or DESA International, have ready:
Parts Not Under Warranty Contact authorized dealers of this product. If they cannot supply original replace- ment part(s), either contact your nearest Parts Central (see page 25) or call DESA International’s Parts Department at 1-800-972-7879 for information.
When calling DESA International, have ready:

These Parts Centrals are privately owned businesses. They have agreed to support our customer’s needs by providing original replacement parts and accessories.
Portable Heater Parts 342 N. County Rd. 400 East Valparaiso, IN 46383 All States 219-462-7441 1-800-362-6951
East Coast Energy Products 707 Broadway W. Long Branch, NJ 07764 908-870-8809 1-800-755-8809
LaPortes Parts & Service 2444 N 5th Street Hartsville, SC 29550 803-332-0191
Cans Unlimited, Inc. P.O. Box 645 Taylor, SC 29687 All States 803-879-3009 1-800-845-5301
FBD 601 Hope Street Bowling Green, KY 42101 502-796-8406 1-800-654-8534
Tarantin Tank Co. P.O. Box 6129 Freehold, NJ 07728 908-780-9340 1-800-922-0724
Dealers LP P.O. Box 341145 Bartlett, TN 38184 AL, TN 901-386-8780 1-800-428-8902
Master Service Center 1184 Wilson NW Walker, MI 49504 616-791-4760 1-800-446-1446
Dayton Hardware P.O. Box 275 North Dayton Station Dayton, OH 45404 All States 513-258-3721 OH 1-800-762-3426
Washer Equipment Co. 1715 Main Street Kansas City, MO 64108 KS, MO, AR 816-842-3911
Halco Enterprises 208 Carter Drive, Unit 21 West Chester, PA 19382 215-696-2670 1-800-368-0803
You can purchase a service manual from the address listed on the back page of this manual. Send a check for $5.00 payable to DESA International.
ACCESSORY Purchase this heater accessory from your local dealer. If they cannot supply this accessory, either contact your nearest Parts Central (see above) or call DESA International’s Parts Department at 1-800-972-7879 for information. You can also write to the address listed on the back page of this manual.
MANUAL SHUTOFF VALVE - GA5010 Manual shutoff valve with 1/8" NPT tap.


GRHpv014C CGP10

This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 24 of this manual.
KEY PART NO. NUMBER DESCRIPTION QTY.
1 098304-01 Screw, #10 x 3/8" 2 2 099467-02 Front Panel Assembly 1 3 099318-04 Grill Guard 1 4 098342-01 Grill Guard Clip 2 5 098533-03AA Bottom Glass Retainer 1 6 098260-03 Glass Panel 1 7 098532-03AA Top Glass Retainer 1 8 M11084-38 Screw, #8 x 3/8" 8 9 098352-03BR Deflector Unit 1 10 098271-03 Ignitor Cable 1 11 098249-01 Nut, M5 2 12 099440-04 ODS/Pilot Assembly 1 12-1 098514-01 Thermocouple 1 12-2 098594-01 Ignitor Electrode 1 13 099386-02 Burner 1 14 099387-05 Pilot Tubing 1 15 098251-07 Injector 1 16 099463-01 Injector Holder 1 17 099415-02 Pressure Regulator 1 18 099462-01 Burner Tubing 1 19 099391-02 Regulator Tubing 1 20 098276-01 1/8" NPT Plug 1 21 099057-01 Pressure Tap Fitting 1 22 099413-02 Control Valve 1 23 099468-01 Cabinet 1 24 097159-02 Piezo Ignitor 1 25 099393-01 Control Knob 1 26 098508-01 Valve Retainer Nut 1 27 098303-02 Screw, #6 x 5/16" 2 28 099553-01 Pilot Shield 1 29 099818-01 Internal Tooth Washer 1
099395-03 Control Position Label 1

Serial No.
Always specify model and serial numbers when communicating with the factory.
We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied.
DESA International warrants this product to be free from defects in materials and components for one (1) year from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions. To make a claim under this warranty the Bill of Sale or cancelled check must be presented.
This warranty is extended only to the original retail purchaser. This warranty covers only the cost of part(s) required to restore this heater to proper operating condition. Warranty part(s) MUST be obtained through authorized dealers of this product and/ or DESA International who will provide original factory replacement parts. Failure to use original factory replacement parts voids this warranty. The heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit.
This warranty does not apply to parts that are not in original condition because of normal wear and tear, or parts that fail or become damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation. Travel, diagnostic cost, labor, transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner.
TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MER- CHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO ONE (1) YEAR FROM THE DATE OF FIRST PURCHASE; AND DESA INTERNATIONAL’S LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND DESA INTERNATIONAL SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSO- EVER INCLUDING INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES.
Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or consequential damages, so the above limitation on implied warranties, or exclusion or limitation on damages may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.
For information about this warranty write:
2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004
Model · Date Purchased
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.