— Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. — WHAT TO DO IF YOU SMELL GAS
— Installation and service must be performed by a qualified installer, service agency, or the gas supplier.
This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohibited by state or local codes.
* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.
Save this manual for future reference.
1 104190

Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning re- semble the flu, with headaches, dizziness, or nausea. If you have these signs, the heater may not be working properly. Get fresh air at once! Have heater serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes.
Natural Gas: Natural gas is odorless. An odor-making agent is added to natural gas. The odor helps you detect a natural gas leak. However, the odor added to natural gas can fade. Natural gas may be present even though no odor exists.
Make certain you read and understand all Warnings. Keep this manual for reference. It is your guide to safe and proper operation of this heater.
2 104190

Ignitor Button Control Knob
Figure 1 - Vent-Free Natural Gas Heater
PRODUCT FEATURES
UNPACKING
Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of the National Fuel Gas Code ANSI Z223, also known as NFPA 54*.
This heater has a pilot with an Oxygen Depletion Sensor Shutoff System (ODS). The ODS/pilot is a required feature for vent- free room heaters. The ODS/pilot shuts off the heater if there is not enough fresh air.
*Available from: American National Standards Institute, Inc.
1430 Broadway New York, NY 10018
National Fire Protection Association, Inc.
This heater has a piezo ignitor. This system requires no matches, batteries, or other sources to light heater.
Batterymarch Park Quincy, MA 02269
Thermostat models have a thermostat sens- ing bulb and a control valve. This results in the greatest heater comfort. This can also result in lower gas bills.

Confined and Unconfined Space
The National Fuel Gas Code (ANSIZ2123.1, 1992 Section 5.3) defines a confined space as a space whose volume is less than 50 cubic feet** per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space. Rooms communicating directly with the space in which the appliances are in- stalled*, through openings not furnished with doors, are considered a part of the unconfined space.
The following is exerpts from National Fuel Gas Code. NFPA 54/ANSI Z223.1, Section 5.3, Air for Combustion and Ventilation.
All spaces in homes fall into one of the three following ventilation classifications: 1. Unusually Tight Contruction 2. Unconfined Space 3. Confined Space.
The information on pages 4 through 6 will help you classify your space and provide adequate ventilation.
Today’s homes are built more energy effi- cient than ever. New materials, increased insulation, and new construction methods help reduce heat loss in homes. Home own- ers weather strip and caulk around windows and doors to keep the cold air out and the warm air in. During heating months, home owners want their homes as airtight as pos- sible.
* Adjoining rooms are communicating only if there are doorless passageways or ventila- tion grills between them.
The air that leaks around doors and win- dows may provide enough fresh air for combustion and ventilation. However, in buildings of unusually tight construction, you must provide additional fresh air.
** Cubic feet equals length x width x height of room.
Unusually tight construction is de- fined as construction where: a. walls and ceilings exposed to the outside atmosphere have a con- tinuous water vapor retarder with a rating of one perm (6x10-11 kg per pa-sec-m2) or less with open- ings gasketed or sealed and b. weather stripping has been added on openable windows and doors and c. caulking or sealants are applied to areas such as joints around window and door frames, be- tween sole plates and floors, be- tween wall-ceiling joints, be- tween wall panels, at penetra- tions for plumbing, electrical, and gas lines, and at other openings.
While it is good to make your home energy efficient, your home needs to breathe. Fresh air must enter your home. All fuel-burning appliances need fresh air for proper com- bustion and ventilation.
Exhaust fans, fireplaces, clothes dryers, and fuel burning appliances draw air from the house to operate. You must provide ad- equate fresh air for these appliances. This will insure proper venting of vented fuel- burning appliances.
If your home meets all of the three criteria above, you must provide ad- ditional fresh air. See Ventilation Air From Outdoors, page 6.
If your home does not meet all of the three criteria above, proceed to page 5.
4 104190

(volume of space) ÷ 50 cu. ft. = (Maximum Btu/Hr the space can support) Example: 2560 cu. ft. (volume of space) ÷ 50 cu. ft. = 51.2 or 51,200 (maximum Btu/Hr the space can sup- port) 3. Add the Btu/Hr of all fuel burning ap- pliances in the space. Vent-free heater Btu/Hr Gas water heater* Btu/Hr Gas furnace Btu/Hr Vented gas heater Btu/Hr Gas fireplace logs Btu/Hr Other gas appliances* + ___ Btu/Hr Total = ___ Btu/Hr Example: Gas water heater 40,000 Btu/Hr Vent-free heater + 20,000 Btu/Hr Total = 60,000 Btu/Hr * Do not include direct-vent gas appli- ances. Direct-vent draws combustion air from the outdoors and vents to the outdoors.
Btu/Hr (maximum the space can support)
Btu/Hr (actual amount of Btu/Hr used) Example: 51,200 Btu/Hr (maximum the space can support)60,000 Btu/Hr (actual amount of Btu/Hr used)
Determining if You Have a Confined or Unconfined Space
The space in the above example is a con- fined space because the actual Btu/Hr used is more than the maximum Btu/Hr the space can support. You must provide additional fresh air. Your options are as follows: A. Rework worksheet, adding the space of an adjoining room. If the extra space provides an unconfined space, remove door to adjoining room or add ventila- tion grills between rooms. See Ventila- tion Air From Inside Building, page 6. B. Vent room directly to the outdoors. See Ventilation Air From Outdoors, page 6. C. Install a lower Btu/Hr heater, if lower Btu/Hr size makes room unconfined.
Use this worksheet to determine if you have a confined or unconfined space.
Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms. 1. Determine the volume of the space (length x width x height). Length x Width x Height =
cu. ft. (volume of space) Example: Space size 20 ft. (length) x 16 ft. (width) x 8 ft. (ceiling height) = 2560 cu. ft. (volume of space) If additional ventilation to adjoining room is supplied with grills or open- ings, add the volume of these rooms to the total volume of the space.
If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support, the space is an unconfined space. You will need no additional fresh air ventilation.
Continued · 5 104190


This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must pro- vide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 2). You can also remove door into adjoining room (see op- tion 3, Figure 2). Follow the National Fuel Gas Code NFPA 54/ANSI Z223.1, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.
Figure 2 - Ventilation Air from Inside Building


Provide extra fresh air by using ventilation grills or ducts. You must provide two per- manent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces.
Figure 3 - Ventilation Air from Outdoors
Outlet Air · 6 104190

Use only natural gas. If your gas supply is not natural gas, do not install heater. Call dealer where you bought heater for proper type heater.
An optional fan kit is available from your dealer. See Accessories, page 19. If plan- ning to use fan, locate heater near an electri- cal outlet.
* An A.G.A. design-certified manual shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Pur- chase the optional A.G.A. design-certified manual shutoff valve from your dealer. See Accessories, page 19.
Minimum From Sides Of Heater
This heater is designed to be mounted on a wall.
Minimum To Top Surface Of Carpeting, Tile Or Other Combustible Material
You can locate heater on floor, away from a wall. An optional floor mounting stand is needed. Purchase the floor mounting stand from your dealer. See Accessories, page 19.
Figure 4 - Mounting Clearances As Viewed From Front of Heater

Methods For Attaching Mounting Bracket To Wall
Only use last hole on each end of mounting bracket to attach bracket to wall. These two holes are 16 inches apart from their centers. Attach mounting bracket to wall in one of two ways. 1. Attaching to wall stud 2. Attaching to wall anchor
Mounting Bracket
The mounting bracket is located on back panel of heater. It has been taped there for shipping. Remove mounting bracket from back panel.
The thermostat sensing bulb has been placed inside the heater for protection during ship- ping.
Locating Thermostat Sensing Bulb 1. Remove front panel of heater (see Fig- ure 7, page 8). 2. Locate thermostat sensing bulb just under burner assembly.

Attaching to wall stud This method provides the strongest hold. Insert mounting screws through mounting bracket and into wall studs.
Attaching to wall anchor This method allows you to attach mounting bracket to hollow walls (wall areas between studs) or to solid walls (concrete or ma- sonry).
Attaching Thermostat Sensing Bulb 1. Remove thermostat sensing bulb from holders inside heater. Route through slot opening in bottom of heater. 2. Place clamp on thermostat sensing bulb as shown in Figure 5. Clamp is pro- vided in hardware package. 3. Snap clamp into upper mounting hole as shown in Figure 5. Mounting hole is located on lower left edge on back of heater. Make sure the thermostat sens- ing bulb is pointing up.
Decide which method better suits your needs. Either method will provide a secure hold for the mounting bracket.
Removing Front Panel Of Heater 1. Remove two screws near bottom cor- ners of front panel. 2. Lift straight up on grill guard until it stops. Grill guard will slide up about 1/4". 3. Pull bottom of front panel forward, then downward. 4. Remove cardboard packing from grill and glass.
Marking Screw Locations 1. Tape mounting bracket to wall where heater will be located. Make sure mounting bracket is level.


Figure 5 - Attaching Thermostat Sensing Bulb
Figure 8 - Mounting Bracket Clearances
Thermostat Sensing Bulb · Clamp · 8 104190

Installing Bottom Mounting Screws 1. Locate two bottom mounting holes. These holes are near bottom on back panel of heater (see Figure 12). 2. Mark screw locations on wall. 3. Remove heater from mounting bracket. 4. If installing bottom mounting screws into hollow or solid wall, install wall anchors. Follow steps 1 through 4 un- der Attaching To Wall Anchor Method, column 1. If installing bottom mounting screw into wall stud, drill holes at marked lo- cations using 9/64" drill bit. 5. Replace heater onto mounting bracket. 6. Place spacers between bottom mount- ing holes and wall anchor or drilled hole. 7. Hold spacer in place with one hand. With other hand, insert mounting screw through bottom mounting hole and spacer. Place tip of screw in opening of wall anchor or drilled hole. 8. Tighten both screws until heater is firmly secured to wall. Do not over tighten. Note: Do not replace front panel at this time. Replace front panel after making gas connections and checking for leaks (see pages 10 and 11).
Attaching to wall stud method
For attaching mounting bracket to wall studs 1. Drill holes at marked locations using 9/64" drill bit. 2. Place mounting bracket onto wall. Line up last hole on each end of bracket with holes drilled in wall. 3. Insert mounting screws through bracket and into wall studs. 4. Tighten screws until mounting bracket is firmly fastened to wall studs.
Figure 10 - Popping Open Anchor Wings For Thin Walls
Attaching to wall anchor method
For attaching mounting bracket to hollow walls (wall areas between studs) or solid walls (concrete or masonry) 1. Drill holes at marked locations using 5/16" drill bit. For solid walls (concrete or masonry), drill at least 1" deep. 2. Fold wall anchor as shown in Figure 9.
Placing Heater On Mounting Bracket 1. Locate two horizontal slots on back panel of heater. 2. Place heater onto mounting bracket. Slide horizontal slots onto stand-out tabs on mounting bracket.
Figure 9 - Folding Anchor
Mounting Bracket (attached to wall)
Figure 11 - Mounting Heater Onto Mounting Bracket
Figure 12 - Installing Bottom Mounting Screws
Horizontal Slots · Stand-Out Tab · 9 104190

Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves.
Install sediment trap in supply line as shown in Figure 13. Locate sediment trap where it is within reach for cleaning. Locate sedi- ment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into heater controls. If sediment trap is not installed or is installed wrong, heater may not run properly.
20,000 Btu/Hr 3/8" or greater
Installation must include a manual shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 13).

3/8" NPT Pipe Nipple
Reducer Bushing to 1/8" NPT
Typical Inlet Pipe from Gas Meter (4" W.C. to 10.5" W.C. Pressure)
1/8" NPT Plug Tap
Figure 13 - Gas Connection
* An A.G.A. design-certified manual shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional A.G.A. design-certified manual shutoff valve from your dealer. See Accessories, page 19.

Test Pressures Equal To or Less Than 1/2 PSIG 1. Close manual shutoff valve (see Fig- ure 14). 2. Pressurize supply piping system by ei- ther using compressed air or opening main gas valve located on or near gas meter. 3. Check all joints from gas meter to manual shutoff valve (see Figure 15). Apply mixture of liquid soap and wa- ter to gas joints. Bubbles forming show a leak. 4. Correct all leaks at once.
PRESSURE TESTING HEATER GAS CONNECTIONS 1. Open manual shutoff valve (see Fig- ure 14). 2. Open main gas valve located on or near gas meter. 3. Make sure control knob of heater is in the OFF position. 4. Check all joints from manual shutoff valve to thermostat gas valve (see Fig- ure 15). Apply mixture of liquid soap and water to gas joints. Bubbles form- ing show a leak. 5. Correct all leaks at once. 6. Light heater (see Operating Heater, pages 12 and 13). Check the rest of the internal joints for leaks. 7. Turn off heater (see To Turn Off Gas to Appliance, page 12). 8. Replace front panel.
PRESSURE TESTING GAS SUPPLY PIPING SYSTEM
Test Pressures In Excess Of 1/2 PSIG 1. Disconnect heater and its individual manual shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig will damage heater regulator. 2. Cap off open end of gas pipe where manual shutoff valve was connected. 3. Pressurize supply piping system by ei- ther using compressed air or opening main gas valve located on or near gas meter. 4. Check all joints of gas supply piping system. Apply mixture of liquid soap and water to gas joints. Bubbles form- ing show a leak. 5. Correct all leaks at once.
Figure 14 - Manual Shutoff Valve
Figure 15 - Checking Gas Joints

Note: If pilot does not stay lit, refer to Troubleshooting, pages 14 through 16. Also contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure, page 13. 7. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Note: If pilot goes out, repeat steps 3 through 7. This heater has a safety interlock system. Wait one (1) minute before lighting pilot again. 8. Turn control knob counterclockwise
READ BEFORE
LIGHTING
Clockwise to the OFF position. 4. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety in- formation in column 1. If you don’t smell gas, go to the next step. 5. Turn control knob counterclockwise
C-clockwise to desired heating level. The main burner should light. Set control knob to any heat level between HI and LO.
C-clockwise to the PILOT position. Press in control knob for five (5) sec- onds (see Figure 16). Note: You may be running this heater for the first time after hook- ing up to gas supply. If so, the con- trol knob may need to be pressed in for 30 seconds. This will allow air to bleed from the gas system. • If control knob does not pop up when released, contact a qualified service person or gas supplier for repairs. 6. With control knob pressed in, push down and release ignitor button. This will light pilot. The pilot is attached to the front of burner. The pilot can be seen through the glass panel. If needed, keep pressing ignitor button until pilot lights.
Figure 17 - Pilot
Ignitor Button Control Knob
TO APPLIANCE
Shutting Off Heater 1. Turn control knob clockwise
LO
PILOT
OFF
HI
Clockwise to the OFF position. 2. Turn off all electric power to the ap- pliance if service is to be performed.
Figure 16 - Control Knob In The OFF Position
Clockwise to the PILOT position.

INSPECTING BURNER
Figure 20 shows a correct burner flame pattern. Figure 21 shows an incorrect burner flame pattern. The incorrect burner flame pattern shows yellow tipping of the flame. It also shows the flame higher than 1/2 the glass panel height.
Check pilot flame pattern and burner flame pattern often.
PILOT FLAME PATTERN
OPERATION
Figure 18 shows a correct pilot flame pat- tern. Figure 19 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool. When the thermocouple cools, the heater will shut down.
The thermostatic control used on these models differs from standard thermo- stats. Standard thermostats simply turn on and off the burner. The thermostat used on this heater senses the room tem- perature. The thermostat adjusts the amount of gas flow to the burner. This increases or decreases the burner flame height. At times the room may exceed the set temperature. If so, the burner will shut off. The burner will cycle back on when room temperature drops below the set temperature. The control knob can be set to any heat level between HI and LO.
Figure 18 - Correct Pilot Flame Pattern
1/2 Glass Height
CORRECT FLAME PATTERN
AT HIGH POSITION
MANUAL LIGHTING
Figure 20 - Correct Burner Flame Pattern
1/2 Glass Height
Figure 19 - Incorrect Pilot Flame Pattern
Figure 21 - Incorrect Burner Flame Pattern

POSSIBLE CAUSE
REMEDY
When ignitor button is pressed, there is no spark at ODS/pilot
When ignitor button is pressed, there is spark at ODS/pilot but no ignition
ODS/pilot lights but flame goes out when control knob is released
14 104190

POSSIBLE CAUSE
REMEDY
Burner does not light after ODS/pilot is lit
Delayed ignition of burner
Burner backfiring during combustion
Yellow flame during burner combustion
Slight smoke or odor during initial opera- tion
Heater produces a whistling noise when burner is lit
Continued · 15 104190

POSSIBLE CAUSE
REMEDY
Heater produces a clicking/ticking noise just after burner is lit or shut off
Heater produces unwanted odors
Heater shuts off in use (ODS operates)
Gas odor even when control knob is in OFF position
Gas odor during combustion
Moisture/condensation noticed on windows
16 104190

SPECIFICATIONS
CGN20TA Btu (Variable) 10,000/20,000 Type Gas Natural Only Ignition Piezo Pressure Regulator Setting 3" W.C. Inlet Gas Pressure (in. of water)
Maximum 10.5" Minimum 4" Dimensions, Inches (H x W x D)
Heater 23.5 x 18.5 x 8.0 Carton 25.8 x 21.3 x 10.1 Weight (pounds)
Heater 22 Shipping 27
TECHNICAL SERVICE
You may have further questions about in- stallation, operation, or troubleshooting. If so, contact DESA International’s Technical Service Department at 1-800-323-5190.
ODS/PILOT AND BURNER • Use a vacuum cleaner, pressurized air, or small, soft bristled brush to clean.
SERVICE HINTS
Air Passageways • Use a vacuum cleaner or pressurized air to clean.
Exterior • Use a soft cloth dampened with a mild soap and water mixture. Wipe the cabi- net to remove dust.
You may feel your gas pressure is too low or gas quality is bad. If so, contact your local natural gas supplier.
You can purchase a service manual from the address listed on the back page of this manual. Send a check for $5.00 payable to DESA International.
17 104190

These Parts Centrals are privately owned businesses. They have agreed to support our customer’s needs by providing original replacement parts and accessories.
Baltimore Electric 1348 Dixwell Avenue Hamden, CT 06514 1-800-397-7553 203-248-7553 Parts Department
Washer Equipment Co. 1715 Main Street Kansas City, MO 64108 KS, MO, AR 816-842-3911
Dayton Hardware P.O. Box 275 North Dayton Station Dayton, OH 45404 All States 513-258-3721 OH 1-800-762-3426
East Coast Energy Products 833 Broadway W. Long Branch, NJ 07764 908-870-8809 1-800-755-8809
Portable Heater Parts 342 N. County Rd. 400 East Valparaiso, IN 46383 All States 219-462-7441 1-800-362-6951
Halco Enterprises 208 Carter Drive, Unit 21 West Chester, PA 19382 215-696-2670 1-800-368-0803
Tarantin Tank Co. P.O. Box 6129 Freehold, NJ 07728 908-780-9340 1-800-922-0724
FBD P.O. Box 1096 1720 Kummer Road Franklin, KY 42134 502-586-1922 1-800-654-8534
LA Porte's Parts & Service 2444 N. 5th Street Hartsville, SC 29550 803-332-0191 Parts Department
Albany Ladder 1586-90 Central Avenue Albany, NY 12205 NY, MA, VT 518-869-5335 1-800-354-7368
Cans Unlimited, Inc. P.O. Box 645 Taylor, SC 29687 All States 803-879-3009 1-800-845-5301
Four Flags Power Products 1115 Stateline Road Niles, MI 49120 616-684-2697 1-800-268-4983
Master Service Center 1184 Wilson NW Walker, MI 49504 616-791-4760 1-800-446-1446
18 104190

Purchase these heater accessories from your local dealer. If they can not supply these accessories, either contact your nearest Parts Central (see page 18) or call DESA International’s Parts Department at 1-800- 972-7879 for referral information. You can also write to the address listed on the back page of this manual.
For all models. Provides better heat distri- bution. Makes heater more efficient. Com- plete installation and operating instructions included.
Manually controlled - GA3100A. Includes ON/OFF switch.
Thermostatically controlled - GA3200TA. Includes three settings: ON/OFF/AUTO.
For locating heater on the floor, away from a wall. Complete installation instructions included.
For all models. Manual shutoff valve with 1/8" NPT tap.
19 104190


20 104190

This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 17 of this manual.
KEY PART NO. NUMBER DESCRIPTION QTY. 1 098304-01 Screw, #10 x 3/8" 2 2 098742-03 Front Panel for CGN20TA (Champagne) 1 3 103476-01 Grill Guard 1 4 101108-01 Removable Speed Clip 2 5 098533-04AA Bottom Glass Retainer 1 6 098260-09 Glass Panel 1 7 098532-04AA Top Glass Retainer 1 8 M11084-26 Screw, #10 x 3/8" 4 9 098352-04BR Deflector Unit 1 10 098271-02 Ignitor Cable 1 11 098249-01 Nut, M5 2 12 099440-05 ODS/Pilot Assembly 1 12-1 098514-01 Thermocouple 1 12-2 098515-01 Ignitor Electrode 1 13 099120-02 Burner 1 14 098517-01 3/16" Pilot Tubing 1 15 098250-01 Injector Holder 1 16 098251-09 Injector 1 17 099415-07 Pressure Regulator 1 18 099553-01 Pilot Shield 1 19 103255-01 3/8" Outlet (Burner) Tubing 1 20 103256-01 3/8" Inlet Tubing 1 21 098522-10 Thermostat Gas Valve 1 22 098530-05 Cabinet for CGN20TA (Woodgrain) 1 23 097159-04 Piezo Ignitor 1 24 M11084-26 Screw, #10 x 3/8" 2 25 M11084-38 Screw, #8 x 3/8" 2 26 099066-01 Mounting Bracket 1
098305-01 Control Position Label 1 100642-01 Hardware Assembly 1
21 104190



Serial No.
Always specify model and serial numbers when communicating with the factory.
We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied.
DESA International warrants this product to be free from defects in materials and components for two (2) years from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions. To make a claim under this warranty the Bill of Sale or cancelled check must be presented.
This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required to restore this heater to proper operating condition and an allowance for labor when provided by a DESA Authorized Service Center. Warranty part(s) MUST be obtained through authorized dealers of this product and/or DESA International who will provide original factory replacement parts. Failure to use original factory replacement parts voids this warranty. The heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit.
This warranty does not apply to parts that are not in original condition because of normal wear and tear, or parts that fail or become damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation. Travel, diagnostic cost, labor, transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner.
TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO TWO (2) YEARS FROM THE DATE OF FIRST PURCHASE; AND DESA INTERNATIONAL’S LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND DESA INTERNATIONAL SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT, INCI- DENTAL OR CONSEQUENTIAL DAMAGES.
Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or consequential damages, so the above limitation on implied warranties, or exclusion or limitation on damages may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.
For information about this warranty write:
2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004
Model · Date Purchased
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.