EN
Desa Tech logo
Official user manual

Desa Tech CGN20TA

24 pages·348 KB·Gas Heater·PDF·ENDEFRITNLJA
Desa Tech CGN20TA
Table of Contents 80 sections OWNER’S OPERATION AND INSTALLATION MANUAL · Heater Size: 20,000 Btu/Hr Thermostat · SAFETY INFORMATION · WARNING ICON G 001 WARNINGS · … ShowHide
OWNER’S OPERATION AND INSTALLATION MANUALp.1Heater Size: 20,000 Btu/Hr Thermostatp.1SAFETY INFORMATIONp.2WARNING ICON G 001 WARNINGSp.2PRODUCT IDENTIFICATIONp.3LOCAL CODESp.3PRODUCT FEATURESp.3UNPACKINGp.3Safety Devicep.3Piezo Ignition Systemp.3Thermostatic Heat Controlp.3FRESH AIR FOR COMBUSTION AND VENTILATIONp.4PROVIDING ADEQUATE VENTILATIONp.4Confined and Unconfined Spacep.4Unusually Tight Constructionp.4FRESH AIR FOR COMBUSTION AND VENTILATION Continuedp.5DETERMINING FRESH-AIR FLOW FOR HEATER LOCATIONp.5Determining if You Have a Confined or Unconfined Spacep.5Ventilation Air From Outdoorsp.6INSTALLATIONp.7CHECK GAS TYPEp.7INSTALLATION ITEMSp.7CEILINGp.7LOCATING HEATERp.7FLOORp.7INSTALLATION Continuedp.8INSTALLING HEATER TO WALLp.8Methods For Attaching Mounting Bracket To Wallp.8THERMOSTAT SENSING BULBp.8Mounting Bracketp.8Attaching Mounting Bracket To Wallp.9CONNECTING TO GAS SUPPLYp.10Typical Inlet Pipe Diametersp.10CHECKING GAS CONNECTIONSp.11ON POSITIONp.11PRESSURE TESTING GAS SUPPLY PIPING SYSTEMp.11OFF POSITIONp.11OPERATING HEATERp.12LIGHTING INSTRUCTIONSp.12FOR YOUR SAFETYp.12READ BEFOREp.12LIGHTINGp.12TO TURN OFF GASp.12TO APPLIANCEp.12Shutting Off Heater 1. Turn control knob clockwisep.12LOp.12PILOTp.12OFFp.12HIp.12IGNITORp.12Shutting Off Burner Only (pilot stays lit) 1. Turn control knob clockwisep.12OPERATING HEATER Continuedp.13INSPECTING BURNERp.13BURNER FLAME PATTERNp.13THERMOSTAT CONTROLp.13PILOT FLAME PATTERNp.13OPERATIONp.131/2 Gp.13CORRECT FLAME PATTERNp.13AT HIGH POSITIONp.13MANUAL LIGHTINGp.13PROCEDUREp.13INCORRECT FLAME PATTERNp.13TROUBLESHOOTINGp.14OBSERVED PROBLEMp.14POSSIBLE CAUSEp.14REMEDYp.14TROUBLESHOOTING Continuedp.15CLEANING AND MAINTENANCEp.17SPECIFICATIONSp.17REPLACEMENT PARTSp.17TECHNICAL SERVICEp.17CABINETp.17SERVICE HINTSp.17SERVICE PUBLICATIONSp.17PARTS CENTRALSp.18ACCESSORIESp.19FAN KITS - GA3100A AND GA3200TAp.19FLOOR MOUNTING STAND - GA4500 - Champagnep.19MANUAL SHUTOFF VALVE - GA5010p.19
Page 1 of the Desa Tech CGN20TA user manual — Heater Size: 20,000 Btu/Hr Thermostat
Page 1 · click to enlarge
Page 1

OWNER’S OPERATION AND INSTALLATION MANUAL

Heater Size: 20,000 Btu/Hr Thermostat

— Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. — WHAT TO DO IF YOU SMELL GAS

  • Do not try to light any appliance.
  • Do not touch any electrical switch; do not use any phone in your building.
  • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
  • If you cannot reach your gas supplier, call the fire department.

— Installation and service must be performed by a qualified installer, service agency, or the gas supplier.

This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohibited by state or local codes.

* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

Save this manual for future reference.

1 104190

Page 2 of the Desa Tech CGN20TA user manual — WARNING ICON G 001 WARNINGS
Page 2 · click to enlarge
Page 2

SAFETY INFORMATION

  • 6. Keep air openings in front and bottom of heater clear and free of debris. This will ensure enough air for proper combustion. 7. If heater shuts off, do not relight until you provide fresh, outside air. If heater keeps shutting off, have it serviced. 8. Do not run heater
  • where flammable liquids or vapors are used or stored
  • under dusty conditions 9. Never place any objects on the heater. 10. Surface of heater becomes very hot when running heater. Keep children and adults away from hot surface to avoid burns or clothing ignition. Heater will remain hot for a time after shut-down. Allow surface to cool before touching. 11. Carefully supervise young children when they are in the same room with heater. 12. Make sure grill guard is in place before running heater. 13. Do not use heater if any part has been under water. Immediately call a qualified service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water. 14. Turn off and unplug heater and let cool before servicing. Only a qualified service person should service and repair heater. 15. Operating heater above elevations of 4,500 feet could cause pilot outage.

WARNING ICON G 001 WARNINGS

  • 1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases. 2. If you smell gas
  • shut off gas supply
  • do not try to light any appliance
  • do not touch any electrical switch; do not use any phone in your building
  • immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions
  • if you cannot reach your gas supplier, call the fire department 3. This heater shall not be installed in a bedroom or bathroom. 4. Never install the heater
  • in a recreational vehicle
  • where curtains, furniture, clothing, or other flammable objects are less than 36 inches from the front, top, or sides of the heater
  • as a fireplace insert
  • in high traffic areas
  • in windy or drafty areas 5. This heater needs fresh, outside air ventilation to run properly. This heater has an oxygen depletion sensor (ODS) pilot light safety system. The ODS shuts down the heater if not enough fresh air is available. See Fresh Air for Combustion and Ventilation, pages 4 through 6.

Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning re- semble the flu, with headaches, dizziness, or nausea. If you have these signs, the heater may not be working properly. Get fresh air at once! Have heater serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes.

Natural Gas: Natural gas is odorless. An odor-making agent is added to natural gas. The odor helps you detect a natural gas leak. However, the odor added to natural gas can fade. Natural gas may be present even though no odor exists.

Make certain you read and understand all Warnings. Keep this manual for reference. It is your guide to safe and proper operation of this heater.

2 104190

Page 3 of the Desa Tech CGN20TA user manual — Thermostatic Heat Control
Page 3 · click to enlarge
Page 3

PRODUCT IDENTIFICATION

Ignitor Button Control Knob

Figure 1 - Vent-Free Natural Gas Heater

LOCAL CODES

PRODUCT FEATURES

UNPACKING

1. Remove heater from carton. 2. Remove all protective packaging applied to heater for shipment. 3. Check heater for any shipping damage. If heater is damaged, promptly inform dealer where you bought heater.

Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of the National Fuel Gas Code ANSI Z223, also known as NFPA 54*.

Safety Device

This heater has a pilot with an Oxygen Depletion Sensor Shutoff System (ODS). The ODS/pilot is a required feature for vent- free room heaters. The ODS/pilot shuts off the heater if there is not enough fresh air.

*Available from: American National Standards Institute, Inc.

1430 Broadway New York, NY 10018

Piezo Ignition System

National Fire Protection Association, Inc.

This heater has a piezo ignitor. This system requires no matches, batteries, or other sources to light heater.

Batterymarch Park Quincy, MA 02269

Thermostatic Heat Control

Thermostat models have a thermostat sens- ing bulb and a control valve. This results in the greatest heater comfort. This can also result in lower gas bills.

Show 5 more labels / short text on this page
Grill Guard · Glass Panel · Heater Cabinet · Front Panel · 3 104190
Page 4 of the Desa Tech CGN20TA user manual — Unusually Tight Construction
Page 4 · click to enlarge
Page 4

FRESH AIR FOR COMBUSTION AND VENTILATION

PROVIDING ADEQUATE VENTILATION

Confined and Unconfined Space

The National Fuel Gas Code (ANSIZ2123.1, 1992 Section 5.3) defines a confined space as a space whose volume is less than 50 cubic feet** per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space. Rooms communicating directly with the space in which the appliances are in- stalled*, through openings not furnished with doors, are considered a part of the unconfined space.

The following is exerpts from National Fuel Gas Code. NFPA 54/ANSI Z223.1, Section 5.3, Air for Combustion and Ventilation.

All spaces in homes fall into one of the three following ventilation classifications: 1. Unusually Tight Contruction 2. Unconfined Space 3. Confined Space.

The information on pages 4 through 6 will help you classify your space and provide adequate ventilation.

Today’s homes are built more energy effi- cient than ever. New materials, increased insulation, and new construction methods help reduce heat loss in homes. Home own- ers weather strip and caulk around windows and doors to keep the cold air out and the warm air in. During heating months, home owners want their homes as airtight as pos- sible.

Unusually Tight Construction

* Adjoining rooms are communicating only if there are doorless passageways or ventila- tion grills between them.

The air that leaks around doors and win- dows may provide enough fresh air for combustion and ventilation. However, in buildings of unusually tight construction, you must provide additional fresh air.

** Cubic feet equals length x width x height of room.

Unusually tight construction is de- fined as construction where: a. walls and ceilings exposed to the outside atmosphere have a con- tinuous water vapor retarder with a rating of one perm (6x10-11 kg per pa-sec-m2) or less with open- ings gasketed or sealed and b. weather stripping has been added on openable windows and doors and c. caulking or sealants are applied to areas such as joints around window and door frames, be- tween sole plates and floors, be- tween wall-ceiling joints, be- tween wall panels, at penetra- tions for plumbing, electrical, and gas lines, and at other openings.

While it is good to make your home energy efficient, your home needs to breathe. Fresh air must enter your home. All fuel-burning appliances need fresh air for proper com- bustion and ventilation.

Exhaust fans, fireplaces, clothes dryers, and fuel burning appliances draw air from the house to operate. You must provide ad- equate fresh air for these appliances. This will insure proper venting of vented fuel- burning appliances.

If your home meets all of the three criteria above, you must provide ad- ditional fresh air. See Ventilation Air From Outdoors, page 6.

If your home does not meet all of the three criteria above, proceed to page 5.

4 104190

Page 5 of the Desa Tech CGN20TA user manual — DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION
Page 5 · click to enlarge
Page 5

FRESH AIR FOR COMBUSTION AND VENTILATION Continued

2. Divide the space volume by 50 cubic feet to determine the maximum Btu/Hr the space can support.
4. Compare the maximum Btu/Hr the space can support with the actual amount of Btu/Hr used.

(volume of space) ÷ 50 cu. ft. = (Maximum Btu/Hr the space can support) Example: 2560 cu. ft. (volume of space) ÷ 50 cu. ft. = 51.2 or 51,200 (maximum Btu/Hr the space can sup- port) 3. Add the Btu/Hr of all fuel burning ap- pliances in the space. Vent-free heater Btu/Hr Gas water heater* Btu/Hr Gas furnace Btu/Hr Vented gas heater Btu/Hr Gas fireplace logs Btu/Hr Other gas appliances* + ___ Btu/Hr Total = ___ Btu/Hr Example: Gas water heater 40,000 Btu/Hr Vent-free heater + 20,000 Btu/Hr Total = 60,000 Btu/Hr * Do not include direct-vent gas appli- ances. Direct-vent draws combustion air from the outdoors and vents to the outdoors.

Btu/Hr (maximum the space can support)

Btu/Hr (actual amount of Btu/Hr used) Example: 51,200 Btu/Hr (maximum the space can support)60,000 Btu/Hr (actual amount of Btu/Hr used)

DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION

Determining if You Have a Confined or Unconfined Space

The space in the above example is a con- fined space because the actual Btu/Hr used is more than the maximum Btu/Hr the space can support. You must provide additional fresh air. Your options are as follows: A. Rework worksheet, adding the space of an adjoining room. If the extra space provides an unconfined space, remove door to adjoining room or add ventila- tion grills between rooms. See Ventila- tion Air From Inside Building, page 6. B. Vent room directly to the outdoors. See Ventilation Air From Outdoors, page 6. C. Install a lower Btu/Hr heater, if lower Btu/Hr size makes room unconfined.

Use this worksheet to determine if you have a confined or unconfined space.

Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms. 1. Determine the volume of the space (length x width x height). Length x Width x Height =

cu. ft. (volume of space) Example: Space size 20 ft. (length) x 16 ft. (width) x 8 ft. (ceiling height) = 2560 cu. ft. (volume of space) If additional ventilation to adjoining room is supplied with grills or open- ings, add the volume of these rooms to the total volume of the space.

If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support, the space is an unconfined space. You will need no additional fresh air ventilation.

Continued · 5 104190

Page 6 of the Desa Tech CGN20TA user manual — Ventilation Air From Outdoors
Page 6 · click to enlarge
Page 6
Desa Tech CGN20TA — Ventilation Air From Outdoors diagram (page 6)
Fig. 1 · Ventilation Air From Outdoors

This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must pro- vide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 2). You can also remove door into adjoining room (see op- tion 3, Figure 2). Follow the National Fuel Gas Code NFPA 54/ANSI Z223.1, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.

Figure 2 - Ventilation Air from Inside Building

Desa Tech CGN20TA — Ventilation Air From Outdoors diagram (page 6)
Fig. 2 · Ventilation Air From Outdoors
Desa Tech CGN20TA — Ventilation Air From Outdoors diagram (page 6)
Fig. 3 · Ventilation Air From Outdoors

Ventilation Air From Outdoors

Provide extra fresh air by using ventilation grills or ducts. You must provide two per- manent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces.

Figure 3 - Ventilation Air from Outdoors

Outlet Air · 6 104190

Page 7 of the Desa Tech CGN20TA user manual — FLOOR
Page 7 · click to enlarge
Page 7

INSTALLATION

  • WARNING: Never install the heater
  • in a bedroom or a bathroom
  • in a recreational vehicle
  • where curtains, furniture, clothing, or other flammable objects are less than 36 inches from the front, top, or sides of the heater
  • as a fireplace insert
  • in high traffic areas
  • in windy or drafty areas

CHECK GAS TYPE

  • CAUTION: If you install the heater in a home garage
  • heater pilot and burner must be at least 18 inches above floor
  • locate heater where moving vehicle will not hit it

Use only natural gas. If your gas supply is not natural gas, do not install heater. Call dealer where you bought heater for proper type heater.

INSTALLATION ITEMS

  • Before installing heater, make sure you have the items listed below.
  • piping (check local codes)
  • sealant (resistant to propane/LP gas)
  • manual shutoff valve *
  • ground joint union
  • test gauge connection * (see Figure 13, page 10)
  • sediment trap
  • tee joint
  • pipe wrench
  • For convenience and efficiency, install heater
  • where there is easy access for operation, inspection, and service
  • in coldest part of room

An optional fan kit is available from your dealer. See Accessories, page 19. If plan- ning to use fan, locate heater near an electri- cal outlet.

* An A.G.A. design-certified manual shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Pur- chase the optional A.G.A. design-certified manual shutoff valve from your dealer. See Accessories, page 19.

CEILING

Minimum From Sides Of Heater

LOCATING HEATER

This heater is designed to be mounted on a wall.

Minimum To Top Surface Of Carpeting, Tile Or Other Combustible Material

You can locate heater on floor, away from a wall. An optional floor mounting stand is needed. Purchase the floor mounting stand from your dealer. See Accessories, page 19.

FLOOR

Figure 4 - Mounting Clearances As Viewed From Front of Heater

Show 8 more labels / short text on this page
36" · Minimum · 6" · Left Side · Right Side · 3" · Continued · 7 104190
Page 8 of the Desa Tech CGN20TA user manual — THERMOSTAT SENSING BULB
Page 8 · click to enlarge
Page 8

INSTALLATION Continued

INSTALLING HEATER TO WALL

Methods For Attaching Mounting Bracket To Wall

Only use last hole on each end of mounting bracket to attach bracket to wall. These two holes are 16 inches apart from their centers. Attach mounting bracket to wall in one of two ways. 1. Attaching to wall stud 2. Attaching to wall anchor

THERMOSTAT SENSING BULB

Mounting Bracket

The mounting bracket is located on back panel of heater. It has been taped there for shipping. Remove mounting bracket from back panel.

The thermostat sensing bulb has been placed inside the heater for protection during ship- ping.

Locating Thermostat Sensing Bulb 1. Remove front panel of heater (see Fig- ure 7, page 8). 2. Locate thermostat sensing bulb just under burner assembly.

Desa Tech CGN20TA — THERMOSTAT SENSING BULB diagram (page 8)
Fig. 4

Attaching to wall stud This method provides the strongest hold. Insert mounting screws through mounting bracket and into wall studs.

Attaching to wall anchor This method allows you to attach mounting bracket to hollow walls (wall areas between studs) or to solid walls (concrete or ma- sonry).

Attaching Thermostat Sensing Bulb 1. Remove thermostat sensing bulb from holders inside heater. Route through slot opening in bottom of heater. 2. Place clamp on thermostat sensing bulb as shown in Figure 5. Clamp is pro- vided in hardware package. 3. Snap clamp into upper mounting hole as shown in Figure 5. Mounting hole is located on lower left edge on back of heater. Make sure the thermostat sens- ing bulb is pointing up.

Decide which method better suits your needs. Either method will provide a secure hold for the mounting bracket.

Removing Front Panel Of Heater 1. Remove two screws near bottom cor- ners of front panel. 2. Lift straight up on grill guard until it stops. Grill guard will slide up about 1/4". 3. Pull bottom of front panel forward, then downward. 4. Remove cardboard packing from grill and glass.

Marking Screw Locations 1. Tape mounting bracket to wall where heater will be located. Make sure mounting bracket is level.

Desa Tech CGN20TA — THERMOSTAT SENSING BULB diagram (page 8)
Fig. 5
Desa Tech CGN20TA — THERMOSTAT SENSING BULB diagram (page 8)
Fig. 6
2. Mark screw locations on wall (see Figure 8). Note: Only mark last hole on each end of mounting bracket. Insert mounting screws through these holes only. 3. Remove tape and mounting bracket from wall.

Figure 5 - Attaching Thermostat Sensing Bulb

Figure 8 - Mounting Bracket Clearances

Thermostat Sensing Bulb · Clamp · 8 104190

Page 9 of the Desa Tech CGN20TA user manual — Attaching Mounting Bracket To Wall
Page 9 · click to enlarge
Page 9

INSTALLATION Continued

3. Insert wall anchor (wings first) into hole. Tap anchor flush to wall. 4. For thin walls (1/2" or less), insert red key into wall anchor. Push red key to “pop” open anchor wings. IMPORTANT: Do not hammer key! For thick walls (over 1/2" thick) or solid walls, do not pop open wings.

Installing Bottom Mounting Screws 1. Locate two bottom mounting holes. These holes are near bottom on back panel of heater (see Figure 12). 2. Mark screw locations on wall. 3. Remove heater from mounting bracket. 4. If installing bottom mounting screws into hollow or solid wall, install wall anchors. Follow steps 1 through 4 un- der Attaching To Wall Anchor Method, column 1. If installing bottom mounting screw into wall stud, drill holes at marked lo- cations using 9/64" drill bit. 5. Replace heater onto mounting bracket. 6. Place spacers between bottom mount- ing holes and wall anchor or drilled hole. 7. Hold spacer in place with one hand. With other hand, insert mounting screw through bottom mounting hole and spacer. Place tip of screw in opening of wall anchor or drilled hole. 8. Tighten both screws until heater is firmly secured to wall. Do not over tighten. Note: Do not replace front panel at this time. Replace front panel after making gas connections and checking for leaks (see pages 10 and 11).

Attaching Mounting Bracket To Wall

Attaching to wall stud method

For attaching mounting bracket to wall studs 1. Drill holes at marked locations using 9/64" drill bit. 2. Place mounting bracket onto wall. Line up last hole on each end of bracket with holes drilled in wall. 3. Insert mounting screws through bracket and into wall studs. 4. Tighten screws until mounting bracket is firmly fastened to wall studs.

Figure 10 - Popping Open Anchor Wings For Thin Walls

5. Place mounting bracket onto wall. Line up last hole on each end of bracket with wall anchors. 6. Insert mounting screws through bracket and into wall anchors. 7. Tighten screws until mounting bracket is firmly fastened to wall.

Attaching to wall anchor method

For attaching mounting bracket to hollow walls (wall areas between studs) or solid walls (concrete or masonry) 1. Drill holes at marked locations using 5/16" drill bit. For solid walls (concrete or masonry), drill at least 1" deep. 2. Fold wall anchor as shown in Figure 9.

Placing Heater On Mounting Bracket 1. Locate two horizontal slots on back panel of heater. 2. Place heater onto mounting bracket. Slide horizontal slots onto stand-out tabs on mounting bracket.

Figure 9 - Folding Anchor

Mounting Bracket (attached to wall)

Figure 11 - Mounting Heater Onto Mounting Bracket

Figure 12 - Installing Bottom Mounting Screws

Horizontal Slots · Stand-Out Tab · 9 104190

Page 10 of the Desa Tech CGN20TA user manual — Typical Inlet Pipe Diameters
Page 10 · click to enlarge
Page 10

CONNECTING TO GAS SUPPLY

Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves.

Install sediment trap in supply line as shown in Figure 13. Locate sediment trap where it is within reach for cleaning. Locate sedi- ment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into heater controls. If sediment trap is not installed or is installed wrong, heater may not run properly.

Typical Inlet Pipe Diameters

20,000 Btu/Hr 3/8" or greater

Installation must include a manual shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 13).

Desa Tech CGN20TA — Typical Inlet Pipe Diameters diagram (page 10)
Fig. 7 · Typical Inlet Pipe Diameters

3/8" NPT Pipe Nipple

Reducer Bushing to 1/8" NPT

Typical Inlet Pipe from Gas Meter (4" W.C. to 10.5" W.C. Pressure)

1/8" NPT Plug Tap

Figure 13 - Gas Connection

* An A.G.A. design-certified manual shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional A.G.A. design-certified manual shutoff valve from your dealer. See Accessories, page 19.

Show 6 more labels / short text on this page
Pressure Regulator · Tee Joint · Test Gauge Connection* · Sediment Trap · Cap · 10 104190
Page 11 of the Desa Tech CGN20TA user manual — OFF POSITION
Page 11 · click to enlarge
Page 11

CHECKING GAS CONNECTIONS

Test Pressures Equal To or Less Than 1/2 PSIG 1. Close manual shutoff valve (see Fig- ure 14). 2. Pressurize supply piping system by ei- ther using compressed air or opening main gas valve located on or near gas meter. 3. Check all joints from gas meter to manual shutoff valve (see Figure 15). Apply mixture of liquid soap and wa- ter to gas joints. Bubbles forming show a leak. 4. Correct all leaks at once.

PRESSURE TESTING HEATER GAS CONNECTIONS 1. Open manual shutoff valve (see Fig- ure 14). 2. Open main gas valve located on or near gas meter. 3. Make sure control knob of heater is in the OFF position. 4. Check all joints from manual shutoff valve to thermostat gas valve (see Fig- ure 15). Apply mixture of liquid soap and water to gas joints. Bubbles form- ing show a leak. 5. Correct all leaks at once. 6. Light heater (see Operating Heater, pages 12 and 13). Check the rest of the internal joints for leaks. 7. Turn off heater (see To Turn Off Gas to Appliance, page 12). 8. Replace front panel.

ON POSITION

PRESSURE TESTING GAS SUPPLY PIPING SYSTEM

Test Pressures In Excess Of 1/2 PSIG 1. Disconnect heater and its individual manual shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig will damage heater regulator. 2. Cap off open end of gas pipe where manual shutoff valve was connected. 3. Pressurize supply piping system by ei- ther using compressed air or opening main gas valve located on or near gas meter. 4. Check all joints of gas supply piping system. Apply mixture of liquid soap and water to gas joints. Bubbles form- ing show a leak. 5. Correct all leaks at once.

OFF POSITION

Figure 14 - Manual Shutoff Valve

Figure 15 - Checking Gas Joints

Show 7 more labels / short text on this page
Manual Shutoff Valve · Open · Closed · Thermostat Gas Valve · Gas Meter · Manual Shutoff Valve · 11 104190
Page 12 of the Desa Tech CGN20TA user manual — Shutting Off Burner Only (pilot stays lit) 1. Turn control knob clockwise
Page 12 · click to enlarge
Page 12

OPERATING HEATER

LIGHTING INSTRUCTIONS

Note: If pilot does not stay lit, refer to Troubleshooting, pages 14 through 16. Also contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure, page 13. 7. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Note: If pilot goes out, repeat steps 3 through 7. This heater has a safety interlock system. Wait one (1) minute before lighting pilot again. 8. Turn control knob counterclockwise

1. STOP! Read the safety information above. 2. Make sure manual shutoff valve is fully open. 3. Turn control knob clockwise

FOR YOUR SAFETY

READ BEFORE

LIGHTING

Clockwise to the OFF position. 4. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety in- formation in column 1. If you don’t smell gas, go to the next step. 5. Turn control knob counterclockwise

  • A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. WHAT TO DO IF YOU SMELL GAS
  • Do not try to light any appliance.
  • Do not touch any electric switch; do not use any phone in your building.
  • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
  • If you cannot reach your gas supplier, call the fire department. C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician or gas supplier. Force or attempted repair may result in a fire or explosion. D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

C-clockwise to desired heating level. The main burner should light. Set control knob to any heat level between HI and LO.

C-clockwise to the PILOT position. Press in control knob for five (5) sec- onds (see Figure 16). Note: You may be running this heater for the first time after hook- ing up to gas supply. If so, the con- trol knob may need to be pressed in for 30 seconds. This will allow air to bleed from the gas system. • If control knob does not pop up when released, contact a qualified service person or gas supplier for repairs. 6. With control knob pressed in, push down and release ignitor button. This will light pilot. The pilot is attached to the front of burner. The pilot can be seen through the glass panel. If needed, keep pressing ignitor button until pilot lights.

Figure 17 - Pilot

Ignitor Button Control Knob

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater 1. Turn control knob clockwise

LO

PILOT

OFF

HI

Clockwise to the OFF position. 2. Turn off all electric power to the ap- pliance if service is to be performed.

IGNITOR

Figure 16 - Control Knob In The OFF Position

Shutting Off Burner Only (pilot stays lit) 1. Turn control knob clockwise

Clockwise to the PILOT position.

Show 4 more labels / short text on this page
Ignitor Electrode · Thermocouple · Pilot Burner · 12 104190
Page 13 of the Desa Tech CGN20TA user manual — AT HIGH POSITION
Page 13 · click to enlarge
Page 13

OPERATING HEATER Continued

INSPECTING BURNER

BURNER FLAME PATTERN

Figure 20 shows a correct burner flame pattern. Figure 21 shows an incorrect burner flame pattern. The incorrect burner flame pattern shows yellow tipping of the flame. It also shows the flame higher than 1/2 the glass panel height.

Check pilot flame pattern and burner flame pattern often.

THERMOSTAT CONTROL

PILOT FLAME PATTERN

OPERATION

Figure 18 shows a correct pilot flame pat- tern. Figure 19 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool. When the thermocouple cools, the heater will shut down.

The thermostatic control used on these models differs from standard thermo- stats. Standard thermostats simply turn on and off the burner. The thermostat used on this heater senses the room tem- perature. The thermostat adjusts the amount of gas flow to the burner. This increases or decreases the burner flame height. At times the room may exceed the set temperature. If so, the burner will shut off. The burner will cycle back on when room temperature drops below the set temperature. The control knob can be set to any heat level between HI and LO.

Figure 18 - Correct Pilot Flame Pattern

1/2 Glass Height

1/2 G

CORRECT FLAME PATTERN

AT HIGH POSITION

MANUAL LIGHTING

Figure 20 - Correct Burner Flame Pattern

PROCEDURE

1. Remove front panel (see Figure 7, page 8). 2. Follow steps 1 through 5 under Lighting Instructions , page 12. 3. With control knob pressed in, strike match. Hold match to pilot until pilot lights. 4. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. 5. Replace front panel.

1/2 Glass Height

INCORRECT FLAME PATTERN

Figure 19 - Incorrect Pilot Flame Pattern

AT HIGH POSITION

  • If pilot flame pattern is incorrect, as shown in Figure 19.
  • turn heater off (see To Turn Off Gas to Appliance , page 12).
  • see Troubleshooting , pages 14 through 16.

Figure 21 - Incorrect Burner Flame Pattern

  • If burner flame pattern is incorrect, as shown in Figure 21
  • turn heater off (see To Turn Off Gas to Appliance , page 12)
  • see Troubleshooting , pages 14 through 16
Show 10 more labels / short text on this page
Pilot Burner · Thermocouple · Correct Flame Pattern · At High Position · Pilot Burner Thermocouple · Yellow Tipping · 1/2 · Incorrect Flame Pattern · At High Position · 13 104190
Page 14 of the Desa Tech CGN20TA user manual — OBSERVED PROBLEM
Page 14 · click to enlarge
Page 14

TROUBLESHOOTING

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

When ignitor button is pressed, there is no spark at ODS/pilot

1. Ignitor electrode positioned wrong 2. Ignitor electrode broken 3. Ignitor electrode not connected to ignitor cable 4. Ignitor cable pinched or wet
1. Replace ignitor 2. Replace ignitor 3. Reconnect ignitor cable
4. Free ignitor cable if pinched by any metal or tubing. Keep ignitor cable dry 5. Tighten nut holding piezo ignitor to heater cabinet. Nut is located inside heater cabinet at top 6. Replace ignitor cable 7. Replace piezo ignitor
5. Piezo ignitor nut is loose
6. Broken ignitor cable 7. Bad piezo ignitor

When ignitor button is pressed, there is spark at ODS/pilot but no ignition

1. Gas supply turned off or manual shutoff valve closed 2. Control knob not in PILOT position 3. Control knob not pressed in while in PILOT position 4. Air in gas lines when installed
1. Turn on gas supply or open manual shutoff valve 2. Turn control knob to PILOT position 3. Press in control knob while in PILOT position 4. Continue holding down control knob. Repeat igniting operation until air is removed 5. Clean ODS/pilot (see Cleaning and Maintenance , page17) or replace ODS/ pilot assembly 6. Replace gas regulator
5. ODS/pilot is clogged
6. Gas regulator setting is not correct

ODS/pilot lights but flame goes out when control knob is released

1. Control knob not fully pressed in 2. Control knob not pressed in long enough
1. Press in control knob fully 2. After ODS/pilot lights, keep control knob pressed in 30 seconds 3. Wait one (1) minute for safety interlock system to reset. Repeat ignition operation 4. Fully open manual shut-off valve 5. Hand tighten until snug, then tighten 1/4 turn more 6. A) Contact local natural gas company B) Clean ODS/pilot (see Cleaning and Maintenance , page 17) or replace ODS/ pilot assembly
3. Safety interlock system has been triggered (Thermostat models only) 4. Manual shutoff valve not fully open 5. Thermocouple connection loose at control valve 6. Pilot flame not touching thermocouple, which allows thermocouple to cool, causing pilot flame to go out. This problem could be caused by one or both of the following: A) Low gas pressure B) Dirty or partially clogged ODS/ pilot 7. Thermocouple damaged 8. Control valve damaged
7. Replace thermocouple 8. Replace control valve

14 104190

Page 15 of the Desa Tech CGN20TA user manual — OBSERVED PROBLEM
Page 15 · click to enlarge
Page 15

TROUBLESHOOTING Continued

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Burner does not light after ODS/pilot is lit

1. Burner orifice is clogged
1. Clean burner (see Cleaning and Maintenance , page 17) or replace burner orifice 2. Replace burner orifice 3. Contact local natural gas company
2. Burner orifice diameter is too small 3. Inlet gas pressure is too low

Delayed ignition of burner

1. Manifold pressure is too low 2. Burner orifice is clogged
1. Contact local natural gas company 2. Clean burner (see Cleaning and Maintenance , page 17) or replace burner orifice

Burner backfiring during combustion

1. Burner orifice is clogged or damaged
1. Clean burner (see Cleaning and Maintenance , page 17) or replace burner orifice 2. Replace burner 3. Replace gas regulator
2. Burner damaged 3. Gas regulator defective

Yellow flame during burner combustion

1. Not enough air
1. Check burner for dirt and debris. If found, clean burner (see Cleaning and Maintenance , page 17) 2. Replace gas regulator
2. Gas regulator defective

Slight smoke or odor during initial opera- tion

1. Residues from manufacturing processes
1. Problem will stop after a few hours of operation

Heater produces a whistling noise when burner is lit

1. Turning control knob to HI position when burner is cold 2. Air in gas line
1. Turn control knob to LO position and let warm up for a minute 2. Operate burner until air is removed from line. Have gas line checked by local natural gas company 3. Observe minimum installation clearances (see Figure 4, page 7) 4. Clean burner (see Cleaning and Maintenance , page 17) or replace burner orifice
3. Air passageways on heater blocked
4. Dirty or partially clogged burner orifice

Continued · 15 104190

Page 16 of the Desa Tech CGN20TA user manual — OBSERVED PROBLEM
Page 16 · click to enlarge
Page 16

TROUBLESHOOTING Continued

  • WARNING: If you smell gas
  • Shut off gas supply.
  • Do not try to light any appliance.
  • Do not touch any electrical switch; do not use any phone in your building.
  • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
  • If you cannot reach your gas supplier, call the fire department.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Heater produces a clicking/ticking noise just after burner is lit or shut off

1. Metal expanding while heating or contracting while cooling
1. This is common with most heaters. If noise is excessive, contact qualified service person

Heater produces unwanted odors

1. Heater burning vapors from paint, hair spray, glues, etc. See IMPORTANT statement above). 2. Gas leak. See Warning statement at top of page
1. Ventilate room. Stop using odor causing products while heater is running
2. Locate and correct all leaks (see Checking Gas Csonnections , page 11)

Heater shuts off in use (ODS operates)

1. Not enough fresh air is available 2. Low line pressure 3. ODS/pilot is partially clogged
1. Open window and/or door for ventilation 2. Contact local propane/LP gas company 3. Clean ODS/pilot (see Cleaning and Maintenance , page 17)

Gas odor even when control knob is in OFF position

1. Gas leak. See Warning statement at top of page 2. Control valve defective
1. Locate and correct all leaks (see Checking Gas Connections , page 11) 2. Replace control valve

Gas odor during combustion

1. Foreign matter between control valve and burner 2. Gas leak. See Warning statement at top of page
1. Take apart gas tubing and remove foreign matter 2. Locate and correct all leaks (see Checking Gas Connections , page 11)

Moisture/condensation noticed on windows

1. Not enough combustion/ventilation air.
1. Refer to Air for Combustion and Ventilation requirements (page 4)

16 104190

Page 17 of the Desa Tech CGN20TA user manual — SERVICE PUBLICATIONS
Page 17 · click to enlarge
Page 17

CLEANING AND MAINTENANCE

SPECIFICATIONS

CGN20TA Btu (Variable) 10,000/20,000 Type Gas Natural Only Ignition Piezo Pressure Regulator Setting 3" W.C. Inlet Gas Pressure (in. of water)

Maximum 10.5" Minimum 4" Dimensions, Inches (H x W x D)

Heater 23.5 x 18.5 x 8.0 Carton 25.8 x 21.3 x 10.1 Weight (pounds)

Heater 22 Shipping 27

REPLACEMENT PARTS

TECHNICAL SERVICE

You may have further questions about in- stallation, operation, or troubleshooting. If so, contact DESA International’s Technical Service Department at 1-800-323-5190.

ODS/PILOT AND BURNER • Use a vacuum cleaner, pressurized air, or small, soft bristled brush to clean.

  • Contact authorized dealers of this product. If they can’t supply original replacement part(s), either contact your nearest Parts Central (see below) or call DESA International’s Technical Service Department at 1-800-323-5190 for referral information. When calling DESA International, have ready
  • your name
  • your address
  • model number of your heater
  • how heater was malfunctioning
  • type of gas used (propane/LP or natural gas)
  • purchase date Usually, we will ask you to return the defective part to the factory. Parts Not Under Warranty

CABINET

SERVICE HINTS

Air Passageways • Use a vacuum cleaner or pressurized air to clean.

  • When gas pressure is too low
  • pilot will not stay lit
  • burner will have delayed ignition
  • heater will not produce specified heat

Exterior • Use a soft cloth dampened with a mild soap and water mixture. Wipe the cabi- net to remove dust.

  • When gas quality is bad
  • pilot will not stay lit
  • burner will produce flames and soot
  • heater will backfire when lit

SERVICE PUBLICATIONS

You may feel your gas pressure is too low or gas quality is bad. If so, contact your local natural gas supplier.

You can purchase a service manual from the address listed on the back page of this manual. Send a check for $5.00 payable to DESA International.

  • Contact authorized dealers of this product. If they can’t supply original replacement part(s), either contact your nearest Parts Central (see below) or call DESA International’s Parts Department at 1-800972-7879 for referral information. When calling DESA International, have ready
  • model number of your heater
  • the replacement part number

17 104190

Page 18 of the Desa Tech CGN20TA user manual — PARTS CENTRALS
Page 18 · click to enlarge
Page 18

PARTS CENTRALS

These Parts Centrals are privately owned businesses. They have agreed to support our customer’s needs by providing original replacement parts and accessories.

Baltimore Electric 1348 Dixwell Avenue Hamden, CT 06514 1-800-397-7553 203-248-7553 Parts Department

Washer Equipment Co. 1715 Main Street Kansas City, MO 64108 KS, MO, AR 816-842-3911

Dayton Hardware P.O. Box 275 North Dayton Station Dayton, OH 45404 All States 513-258-3721 OH 1-800-762-3426

East Coast Energy Products 833 Broadway W. Long Branch, NJ 07764 908-870-8809 1-800-755-8809

Portable Heater Parts 342 N. County Rd. 400 East Valparaiso, IN 46383 All States 219-462-7441 1-800-362-6951

Halco Enterprises 208 Carter Drive, Unit 21 West Chester, PA 19382 215-696-2670 1-800-368-0803

Tarantin Tank Co. P.O. Box 6129 Freehold, NJ 07728 908-780-9340 1-800-922-0724

FBD P.O. Box 1096 1720 Kummer Road Franklin, KY 42134 502-586-1922 1-800-654-8534

LA Porte's Parts & Service 2444 N. 5th Street Hartsville, SC 29550 803-332-0191 Parts Department

Albany Ladder 1586-90 Central Avenue Albany, NY 12205 NY, MA, VT 518-869-5335 1-800-354-7368

Cans Unlimited, Inc. P.O. Box 645 Taylor, SC 29687 All States 803-879-3009 1-800-845-5301

Four Flags Power Products 1115 Stateline Road Niles, MI 49120 616-684-2697 1-800-268-4983

Master Service Center 1184 Wilson NW Walker, MI 49504 616-791-4760 1-800-446-1446

18 104190

Page 19 of the Desa Tech CGN20TA user manual — MANUAL SHUTOFF VALVE - GA5010
Page 19 · click to enlarge
Page 19

ACCESSORIES

FAN KITS - GA3100A AND GA3200TA

Purchase these heater accessories from your local dealer. If they can not supply these accessories, either contact your nearest Parts Central (see page 18) or call DESA International’s Parts Department at 1-800- 972-7879 for referral information. You can also write to the address listed on the back page of this manual.

For all models. Provides better heat distri- bution. Makes heater more efficient. Com- plete installation and operating instructions included.

Manually controlled - GA3100A. Includes ON/OFF switch.

Thermostatically controlled - GA3200TA. Includes three settings: ON/OFF/AUTO.

FLOOR MOUNTING STAND - GA4500 - Champagne

For locating heater on the floor, away from a wall. Complete installation instructions included.

MANUAL SHUTOFF VALVE - GA5010

For all models. Manual shutoff valve with 1/8" NPT tap.

19 104190

Page 20 of the Desa Tech CGN20TA user manual — ILLUSTRATED PARTS BREAKDOWN
Page 20 · click to enlarge
Page 20

ILLUSTRATED PARTS BREAKDOWN

Desa Tech CGN20TA — ILLUSTRATED PARTS BREAKDOWN diagram (page 20)
Fig. 8

20 104190

Page 21 of the Desa Tech CGN20TA user manual — PARTS AVAILABLE — NOT SHOWN
Page 21 · click to enlarge
Page 21

PARTS LIST

This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 17 of this manual.

KEY PART NO. NUMBER DESCRIPTION QTY. 1 098304-01 Screw, #10 x 3/8" 2 2 098742-03 Front Panel for CGN20TA (Champagne) 1 3 103476-01 Grill Guard 1 4 101108-01 Removable Speed Clip 2 5 098533-04AA Bottom Glass Retainer 1 6 098260-09 Glass Panel 1 7 098532-04AA Top Glass Retainer 1 8 M11084-26 Screw, #10 x 3/8" 4 9 098352-04BR Deflector Unit 1 10 098271-02 Ignitor Cable 1 11 098249-01 Nut, M5 2 12 099440-05 ODS/Pilot Assembly 1 12-1 098514-01 Thermocouple 1 12-2 098515-01 Ignitor Electrode 1 13 099120-02 Burner 1 14 098517-01 3/16" Pilot Tubing 1 15 098250-01 Injector Holder 1 16 098251-09 Injector 1 17 099415-07 Pressure Regulator 1 18 099553-01 Pilot Shield 1 19 103255-01 3/8" Outlet (Burner) Tubing 1 20 103256-01 3/8" Inlet Tubing 1 21 098522-10 Thermostat Gas Valve 1 22 098530-05 Cabinet for CGN20TA (Woodgrain) 1 23 097159-04 Piezo Ignitor 1 24 M11084-26 Screw, #10 x 3/8" 2 25 M11084-38 Screw, #8 x 3/8" 2 26 099066-01 Mounting Bracket 1

PARTS AVAILABLE — NOT SHOWN

098305-01 Control Position Label 1 100642-01 Hardware Assembly 1

21 104190

Page 22 of the Desa Tech CGN20TA user manual — NOTES
Page 22 · click to enlarge
Page 22

NOTES

Show 35 more labels / short text on this page
_______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · 22 104190
Page 23 of the Desa Tech CGN20TA user manual — NOTES
Page 23 · click to enlarge
Page 23

NOTES

Show 35 more labels / short text on this page
_______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · 23 104190
Page 24 of the Desa Tech CGN20TA user manual — 104190-01 REV. A 09/97
Page 24 · click to enlarge
Page 24

WARRANTY INFORMATION

KEEP THIS WARRANTY

Serial No.

Always specify model and serial numbers when communicating with the factory.

We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied.

LIMITED WARRANTY COMFORT GLOW VENT-FREE NATURAL GAS HEATERS

DESA International warrants this product to be free from defects in materials and components for two (2) years from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions. To make a claim under this warranty the Bill of Sale or cancelled check must be presented.

This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required to restore this heater to proper operating condition and an allowance for labor when provided by a DESA Authorized Service Center. Warranty part(s) MUST be obtained through authorized dealers of this product and/or DESA International who will provide original factory replacement parts. Failure to use original factory replacement parts voids this warranty. The heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit.

This warranty does not apply to parts that are not in original condition because of normal wear and tear, or parts that fail or become damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation. Travel, diagnostic cost, labor, transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner.

TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO TWO (2) YEARS FROM THE DATE OF FIRST PURCHASE; AND DESA INTERNATIONAL’S LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND DESA INTERNATIONAL SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT, INCI- DENTAL OR CONSEQUENTIAL DAMAGES.

Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or consequential damages, so the above limitation on implied warranties, or exclusion or limitation on damages may not apply to you.

This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.

For information about this warranty write:

104190 01 NOT A UPC

2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004

104190-01 REV. A 09/97

Model · Date Purchased

Ask about the Desa Tech CGN20TA

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Desa Tech CGN20TA

Be the first to ask — other owners or our team will answer.

Original document

Desa Tech CGN20TA manual PDF

24 pages·348 KB·Gas Heater·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…