Table of Contents 80 sections UNVENTED (VENT-FREE) PROPANE/LP GAS LOG HEATER · (Variable Manually-Controlled Models Also Designed-Certified as · Vented Decorative Appliances) OWNER’S OPERATION AND INSTALLATION MANUAL · CGG2618P, CGG3324P(T), and · … ShowHide
UNVENTED (VENT-FREE) PROPANE/LP GAS LOG HEATERp.1(Variable Manually-Controlled Models Also Designed-Certified asp.1Vented Decorative Appliances) OWNER’S OPERATION AND INSTALLATION MANUALp.1CGG2618P, CGG3324P(T), andp.1CGG3630Pp.1Thermostat and Variably-Controlled Modelsp.1— Do not store or use gasoline or otherp.1SAFETY INFORMATIONp.2WARNINGSp.2PRODUCT IDENTIFICATIONp.3PRODUCT FEATURESp.3OPERATIONp.3SAFETY PILOTp.3PIEZO IGNITION SYSTEMp.3LOCAL CODESp.3UNPACKINGp.3AIR FOR COMBUSTION AND VENTILATIONp.4PROVIDING ADEQUATE VENTILATIONp.4Confined and Unconfined Spacep.4Unusually Tight Constructionp.4AIR FOR COMBUSTION AND VENTILATION Continuedp.5DETERMINING FRESH-AIR FLOW FOR HEATER LOCATIONp.5Determining if You Have a Confined or Unconfined Spacep.5VENTILATION AIRp.6Ventilation Air From Inside Buildingp.6Ventilation Air From Outdoorsp.6INSTALLATIONp.7INSTALLATION AND CLEARANCES (Vent-Free Operation Only)p.7CHECK GAS TYPEp.7INSTALLATION Continuedp.8Minimum Noncombustible Material Clearancesp.8Mantel Shelf INSTALLATION Continuedp.9MANTEL CLEARANCESp.9(A)p.9Determining Minimum Mantel Clearancep.9Determining Minimum Mantel Clearance When Using a Hoodp.9INSTALLING DAMPER CLAMP ACCESSORY FOR VENTED OPERATIONp.10INSTALLING HEATER BASE ASSEMBLYp.10CONNECTING TO GAS SUPPLYp.12Installation Items Neededp.12CHECKING GAS CONNECTIONSp.13ON POSITp.13O POp.13Pressure Testing Gas Supply Piping Systemp.13INSTALLING LOGSp.14OPERATING HEATER Thermostat-Controlled Modelsp.15LIGHTING INSTRUCTIONSp.15FOR YOUR SAFETYp.15READ BEFOREp.15LIGHTINGp.15HIp.15PILOTp.15OFFp.15LOp.15Variable Manually-Controlled Models OPERATING HEATER Continuedp.16FOR YOUR SAFETY READ BEFORE LIGHTINGp.16TO TURN OFF GASp.16TO APPLIANCEp.16Shutting Off Heaterp.16Shutting Off Burners Only (pilot stays lit)p.16(Thermostat-Controlledp.16Models Only)p.16MANUAL LIGHTINGp.16OPERATING HEATER Continuedp.17VARIABLE CONTROLp.17INSPECTING BURNERSp.17PILOT FLAME PATTERNp.17INSPECTING BURNERS Continuedp.18CLEANING AND MAINTENANCEp.18FRONT BURNER FLAME PATTERNp.18CLEANING BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLEp.18OBSERVED PROBLEMp.19POSSIBLE CAUSEp.19REMEDYp.19TROUBLESHOOTING Continuedp.20OPTIONAL POSITIONING OF THERMOSTAT SENSING BULBp.22FOR MASONRY AND FACTORY-BUILT METAL FIREPLACEp.22 Q ¢ p.22SPECIFICATIONSp.23SERVICE HINTSp.23
Page 1 of the Desa Tech CGG3630P user manual — — Do not store or use gasoline or other
Page 1 · click to enlarge
Page 1

UNVENTED (VENT-FREE) PROPANE/LP GAS LOG HEATER

(Variable Manually-Controlled Models Also Designed-Certified as

Vented Decorative Appliances) OWNER’S OPERATION AND INSTALLATION MANUAL

CGG2618P, CGG3324P(T), and

CGG3630P

Thermostat and Variably-Controlled Models

— Do not store or use gasoline or other

  • flammable vapors and liquids in the vicinity of this or any other appliance. — WHAT TO DO IF YOU SMELL GAS
  • Do not try to light any appliance.
  • Do not touch any electrical switch; do not use any phone in your building.
  • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
  • If you cannot reach your gas supplier, call the fire department. — Installation and service must be per-

WARNING: This appliance is for instal- lation only in a solid-fuel burning ma- sonry or UL127 factory-built fireplace, or in an approved ventless firebox. It is design-certified for these installations in accordance with ANS Z21.11.2. Ex- ception: Do not install this appliance in a factory-built fireplace that includes instructions stating it has not been tested or should not be used with unvented gas logs.

formed by a qualified installer, ser- vice agency, or the gas supplier.

This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohibited by state or local codes.

* AftermarketCompletion of sale, not for purpose of resale, from the manufacturer

Save this manual for future reference.

Page 2 of the Desa Tech CGG3630P user manual — WARNINGS
Page 2 · click to enlarge
Page 2

SAFETY INFORMATION

  • do not touch any electrical switch; do not use any phone in your building
  • immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions
  • if you cannot reach your gas supplier, call the fire department 4. This heater shall not be installed in a bedroom or bathroom unless installed as a vented appliance (see Installing Damper Clamp , page 10). 5. Never install the heater
  • in a recreational vehicle
  • where curtains, furniture, clothing, or other flammable objects are less than 42 inches from the front, top, or sides of the heater
  • in high traffic areas
  • in windy or drafty areas 6. Before installing in a solid fuel burning fireplace, the chimney flue and firebox must be cleaned of soot, creosote, ashes and loose paint by a qualified chimney cleaner. Creosote will ignite if highly heated. Inspect chimney flue for damage. If damaged, operate heater with flue damper closed. 7. If fireplace has glass doors, never operate this heater with glass doors closed. If you operate heater with doors closed, heat buildup inside fireplace will cause glass to burst. Also if fireplace opening has vents at the bottom, you must open the vents before operating heater. 8. You must operate this heater with a fireplace screen in place. Make sure fireplace screen is closed before running heater. 9. This log heater is designed to be smokeless. If logs ever appear to smoke, turn off heater and call a qualified service person. Note: During initial operation, slight smoking could occur due to log curing and heater burning manufacturing residues. 10. To prevent the creation of soot, follow the instructions in Cleaning and Maintenance, page 18. 11. Do not allow fans to blow directly into the fireplace. Avoid any drafts that alter burner flame patterns. Ceiling fans can create drafts that alter burner flame patterns. Altered burner patterns can cause sooting.
  • 12. Before using furniture polish, wax, carpet cleaner, or similar products, turn heater off. If heated, the vapors from these products may create a white powder residue within burner box or on adjacent walls or furniture. 13. Do not use a blower insert, heat exchanger insert or other accessory not approved for use with this heater. 14. This heater needs fresh, outside air ventilation to run properly. This heater has an oxygen depletion sensor (ODS) pilot light safety system. The ODS shuts down the heater if not enough fresh air is available. See Air for Combustion and Ventilation, pages 4 through 6. If heater keeps shutting off, see Troubleshooting, pages 19 through 21. 15. Do not run heater
  • where flammable liquids or vapors are used or stored
  • under dusty conditions 16. Do not use this heater to cook food or burn paper or other objects. 17. Never place any objects on the heater. 18. Heater base assembly becomes very hot when running heater. Keep children and adults away from hot surface to avoid burns or clothing ignition. Heater will remain hot for a time after shutdown. Allow surface to cool before touching. 19. Carefully supervise young children when they are in the room with heater. 20. Do not use heater if any part has been exposed to or under water. Immediately call a qualified service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water. 21. Do not operate heater if any log is broken. Do not operate heater if a log is chipped (dime-sized or larger). 22. Turn heater off and let cool before servicing. Only a qualified service person should service and repair heater. 23. Operating heater above elevations of 4,500 feet could cause pilot outage. 24. To prevent performance problems, do not use propane/LP tank of less than 100 lbs. capacity.

WARNINGS

Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning re- semble the flu, with headaches, dizziness, or nausea. If you have these signs, the heater may not be working properly. Get fresh air at once! Have heater serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes.

Propane/LP Gas: Propane/LP gas is odor- less. An odor-making agent is added to the gas. The odor helps you detect a gas leak. How- ever, the odor added to the gas can fade. Gas may be present even though no odor exists.

Make certain you read and understand all Warnings. Keep this manual for reference. It is your guide to safe and proper operation of this heater.

  • 1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases. 2. Do not place propane/LP supply tank(s) inside any structure. Locate propane/ LP supply tank(s) outdoors. 3. If you smell gas
  • shut off gas supply
  • do not try to light any appliance

2 103425

Page 3 of the Desa Tech CGG3630P user manual — LOCAL CODES
Page 3 · click to enlarge
Page 3

PRODUCT IDENTIFICATION

PRODUCT FEATURES

OPERATION

Bottom Mid Log (#2)

This heater is clean burning. It requires no outside venting. There is no heat loss out a vent or up a chimney. Heat is generated by both realistic flames and glowing coals. This heater is designed for vent-free opera- tion. It has been tested and approved to ANS Z21.11.2 standard for unvented heaters. State and local codes in some areas prohibit the use of vent-free heaters. This heater may also be operated as a vented decorative (ANS Z21.60) product by opening the flue damper (non-thermostat operation only).

SAFETY PILOT

This heater has a pilot with an Oxygen Depletion Sensor Shutoff System (ODS). The ODS/pilot is a required feature for vent- free room heaters. The ODS/pilot shuts off the heater if there is not enough fresh air.

PIEZO IGNITION SYSTEM

This heater has a piezo ignitor. This system requires no matches, batteries, or other sources to light heater.

Figure 1 - Vent-Free Gas Log Heater

LOCAL CODES

UNPACKING

Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANS Z223, also known as NFPA 54*.

*Available from:

American National Standards Institute, Inc.

1430 Broadway New York, NY 10018

1. Remove logs and heater base assembly from carton. Note: Do not pick up heater base assembly by burners. This could damage heater. Always handle base assembly by grate. 2. Remove all protective packaging applied to logs and heater for shipment. 3. Check all items for any shipping damage. If damaged, promptly inform dealer where you bought heater.

National Fire Protection Association, Inc.

Batterymarch Park Quincy, MA 02269

Show 9 more labels / short text on this page
Top Log (#4) · Rear Log (#1) · Front Burner · Rear Burner · Piezo Ignitor · Front Log (#3) · Base Assembly · Control Knob · 3 103425
Page 4 of the Desa Tech CGG3630P user manual — Unusually Tight Construction
Page 4 · click to enlarge
Page 4

AIR FOR COMBUSTION AND VENTILATION

PROVIDING ADEQUATE VENTILATION

Confined and Unconfined Space

The National Fuel Gas Code (ANS Z223.1, 1992 Section 5.3) defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space and an unconfining space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space. Rooms communicating directly with the space in which the appliances are in- stalled*, through openings not furnished with doors, are considered a part of the unconfined space.

The following are excerpts from National Fuel Gas Code. NFPA 54/ANS Z223.1, Sec- tion 5.3, Air for Combustion and Ventilation.

All spaces in homes fall into one of the three following ventilation classifications: 1. Unusually Tight Construction 2. Unconfined Space 3. Confined Space

The information on pages 4 through 6 will help you classify your space and provide adequate ventilation.

Today’s homes are built more energy efficient than ever. New materials, increased insula- tion, and new construction methods help re- duce heat loss in homes. Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in. During heating months, home owners want their homes as airtight as possible.

Unusually Tight Construction

This heater shall not be installed in a con- fined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air.

The air that leaks around doors and win- dows may provide enough fresh air for com- bustion and ventilation. However, in build- ings of unusually tight construction, you must provide additional fresh air.

* Adjoining rooms are communicating only if there are doorless passageways or ventila- tion grills between them.

Unusually tight construction is de- fined as construction where: a. walls and ceilings exposed to the outside atmosphere have a continuous water vapor retarder with a rating of one perm (6 x 10-11 kg per pa-sec-m2) or less with openings gasketed or sealed and b. weather stripping has been added on openable windows and doors and c. caulking or sealants are applied to areas such as joints around window and door frames, be- tween sole plates and floors, be- tween wall-ceiling joints, between wall panels, at penetrations for plumbing, electrical, and gas lines, and at other openings.

While it is good to make your home energy efficient, your home needs to breathe. Fresh air must enter your home. All fuel-burning appliances need fresh air for proper com- bustion and ventilation.

Exhaust fans, fireplaces, clothes dryers, and fuel burning appliances draw air from the house to operate. You must provide ad- equate fresh air for these appliances. This will insure proper venting of vented fuel- burning appliances.

If your home meets all of the three criteria above, you must provide ad- ditional fresh air. See Ventilation Air From Outdoors, page 6.

If your home does not meet all of the three criteria above, proceed to De- termining Fresh-Air Flow for Heater Location, page 5.

4 103425

Page 5 of the Desa Tech CGG3630P user manual — DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION
Page 5 · click to enlarge
Page 5

AIR FOR COMBUSTION AND VENTILATION Continued

DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION

Determining if You Have a Confined or Unconfined Space

Use this worksheet to determine if you have a confined or unconfined space.

Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms. 1. Determine the volume of the space (length x width x height). Length x Width x Height = cu. ft. (volume of space) Example: Space size 20ft. (length) x 16 ft. (width) x 8 ft. (ceiling height) = 2560 cu. ft. (volume of space) If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these rooms to the total volume of the space. 2. Divide the space volume by 50 cubic feet to determine the maximum Btu/Hr the space can support.

(volume of space) ÷ 50 cu. ft. = (Maximum Btu/Hr the space can support) Example: 2560 cu. ft. (volume of space) ÷ 50 cu. ft. = 51.2 or 51,200 (maximum Btu/Hr the space can support) 3. Add the Btu/Hr of all fuel burning appliances in the space. Vent-free heater Btu/Hr Gas water heater* Btu/Hr Gas furnace Btu/Hr Vented gas heater Btu/Hr Gas fireplace logs Btu/Hr Other gas appliances* + Btu/Hr Total = Btu/Hr * Do not include direct-vent gas appliances. Direct-vent draws combustion air from the outdoors and vents to the outdoors. 4. Compare the maximum Btu/Hr the space can support with the actual amount of Btu/Hr used.

ExampleGas water heater 40,000 Btu/Hr Vent-free heater + 33,000 Btu/Hr Total = 73,000 Btu/Hr

Btu/Hr (maximum the space can support) Btu/Hr (actual amount of Btu/Hr used) Example: 51,200 Btu/Hr (maximum the space can support) 73,000 Btu/Hr (actual amount of Btu/Hr used)

The space in the above example is a confined space because the actual Btu/Hr used is more than the maximum Btu/Hr the space can support. You must provide additional fresh air. Your options are as follows: A. Rework worksheet, adding the space of an adjoining room. If the extra space provides an unconfined space, remove door to adjoin- ing room or add ventilation grills between rooms. See Ventilation Air From Inside Building, page 6. B. Vent room directly to the outdoors. See Ventilation Air From Outdoors, page 6. C. Install a lower Btu/Hr heater, if lower Btu/Hr size makes room unconfined.

If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support, the space is an unconfined space. You will need no additional fresh air ventilation.

Continued · 5 103425

Page 6 of the Desa Tech CGG3630P user manual — Ventilation Air From Outdoors
Page 6 · click to enlarge
Page 6

AIR FOR COMBUSTION AND VENTILATION Continued

Ventilation Grills Into Adjoining Room,

VENTILATION AIR

Or Remove Door into Adjoining

Ventilation Air From Inside Building

This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must pro- vide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 2). You can also remove door into adjoining room (see op- tion 3, Figure 2). Follow the National Fuel Gas Code NFPA 54/ANS Z223.1, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.

Figure 2 - Ventilation Air from Inside Building

Ventilation Air From Outdoors

Provide extra fresh air by using ventilation grills or ducts. You must provide two per- manent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces.

Inlet Air Ventilated Crawl Space

Figure 3 - Ventilation Air from Outdoors

Show 14 more labels / short text on this page
12" · Ventilation · Grills Into Adjoining · Room, Option 1 · Option 2 · Room, Option · 12" · Ventilated Attic · Outlet Air · Outlet Air · To Attic · To Crawl Space · Inlet Air · 6 103425
Page 7 of the Desa Tech CGG3630P user manual — CHECK GAS TYPE
Page 7 · click to enlarge
Page 7

INSTALLATION

INSTALLATION AND CLEARANCES (Vent-Free Operation Only)

  • WARNING: Never install the heater
  • in a bedroom or bathroom unless installed as a vented appliance, see page 10
  • in a recreational vehicle
  • where curtains, furniture, clothing, or other flammable objects are less than 42 inches from the front, top, or sides of the heater
  • in high traffic areas
  • in windy or drafty areas

NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your pri- mary heating system. Do not in- stall this heater as your primary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circu- late the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source.

MINIMUM FIREPLACE CLEARANCE TO COMBUSTIBLE MATERIALS Log SizeSide WallCeiling 18", 24", 30"16"42"
LOG SIZING REQUIREMENTS Log SizeMinimum Firebox HeightDepthFront Width 18" 24" 30"17" 17" 17"14" 14" 14"20" 26" 32"

Carefully follow the instructions below. This will ensure safe installation into a masonry, UL127-listed manufactured fireplace, or listed vent-free firebox.

Minimum Wall and Ceiling Clearances (see Figure 4) A. Clearances from the side of the fireplace opening to any combustible wall should not be less than 16 inches. B. Clearances from the top of the fireplace opening to the ceiling should not be less than 42 inches.

CHECK GAS TYPE

Use only propane/LP gas. If your gas supply is not propane/LP, do not install heater. Call dealer where you bought heater for proper type heater.

16" Left and Right Sides

Figure 4 - Minimum Clearance to Wall and Ceiling

42" · Continued · 7 103425

Page 8 of the Desa Tech CGG3630P user manual — Minimum Noncombustible Material Clearances
Page 8 · click to enlarge
Page 8

INSTALLATION Continued

if noncombustible material is more than 12", you may need the hood accessory to deflect heat away from your mantel shelf. See Figure 5 and Figures 6 and 7, page 9, for minimum clearances.

You must have noncombustible material(s) above the fireplace opening. Noncombus- tible materials (such as slate, marble, tile, etc.) must be at least 1/2 inch thick. With sheet metal, you must have noncombustible material behind it. Noncombustible mate- rial must extend at least 8 inches up (for all models). If noncombustible material is less than 12", you must install the fireplace hood accessory (24" and 30" models only). Even

Noncombustible Material Distance (A)Requirements for Safe Installation 12" or more Between 8" and 12" Less than 8"Noncombustible material OK. 24" or 30" Models: Install fireplace hood accessory (GA6050 or GA6052, see Accessories, page 28). 18" Model: Noncombustible material OK. No hood accessory needed. Noncombustible material must be extended to at least 8". See Between 8" and 12", above. If you cannot extend material, you must operate heater with flue damper open. Heat Resistant Material (A) Figure 5 - Heat Resistant Material (Slate, Marble, Tile, etc.) Above Fireplace

Minimum Noncombustible Material Clearances

If Not Using Mantel

You must have noncombustible material(s) above the fireplace opening. Noncombus- tible materials (such as slate, marble, tile, etc.) must be at least 1/2 inch thick. With sheet metal, you must have noncombustible material behind it. Noncombustible mate- rial must extend at least 8" up (for all mod- els). If noncombustible material is less than 12", you must install the fireplace hood accessory (24" and 30" models only). See Figure 5 for minimum clearances.

If Using Mantel · 8 103425

Page 9 of the Desa Tech CGG3630P user manual — Determining Minimum Mantel Clearance When Using a Hood
Page 9 · click to enlarge
Page 9

Mantel Shelf INSTALLATION Continued

Underside of Mantel Shelf

MANTEL CLEARANCES

2 1/2"

In addition to meeting noncombustible mate- rial clearances, you must also meet required clearances between fireplace opening and mantel shelf. If you do not meet the clear- ances listed below, you will need a hood.

All minimum distances are in inches

(A)

Log Set 24"/30" Models

Determining Minimum Mantel Clearance

If you meet minimum clearance between mantel shelf and top of fireplace opening, a hood is not required (see Figure 6).

Top of Fireplace Opening

Minimum Non- Combustible Material Height

Distances to Underside of Mantel

Determining Minimum Mantel Clearance When Using a Hood

If minimum clearances in Figure 6 are not met, you must have a hood. When using a hood there are still certain minimum mantel clearances required. Follow minimum clear- ances shown in Figure 7 when using hood.

Figure 6 - Minimum Mantel Clearances Without Using Hood

Underside of Mantel Shelf

  • NOTICE: If your installation does not meet the minimum clearances shown, you must do one of the following:
  • operate the logs only with the flue damper open
  • raise the mantel to an acceptable height
  • remove the mantel

2 1/2"

All minimum distances are in inches

Minimum Non- Combustible Material 8" Min.

18", 24", & 30" Models 20"

Top of Fireplace Opening

Distances to Underside of Mantel

FLOOR CLEARANCES A. If installing appliance on the floor level, you must maintain the minimum dis- tance of 14" to combustibles (see Fig- ure 8). B. If combustible materials are less than 14" from the fireplace, you must install appliance at least 5" above the combustible flooring (see Figure 9).

Figure 7 - Minimum Mantel Clearances When Using Hood

14" Min.

5" Min.

Figure 9 - Minimum Fireplace Clearances Above Combustible Flooring Figure 8 - Minimum Fireplace Clearances If Installed at Floor Level

Show 29 more labels / short text on this page
10" · 8" · 6" · Minimum Non- Combustible Material · 12" · 20" · 25" · 28" · 30" · 8" · 14" · 17" · 19" · 20" · 18" Model · Mantel Shelf · 12" · 10" · 8" · 6" · Log Sets · 12" 15" 18" · Hood (GA6050, GA6052) · Combustible Material · Hearth · Combustible Material · Noncombustible Material · Continued · 9 103425
Page 10 of the Desa Tech CGG3630P user manual — INSTALLING HEATER BASE ASSEMBLY
Page 10 · click to enlarge
Page 10

INSTALLATION Continued

See chart below for minimum permanent flue opening you must provide. Attach damper clamp so the minimum permanent flue opening will be maintained at all times.

INSTALLING DAMPER CLAMP ACCESSORY FOR VENTED OPERATION

Chimney Height (ft.)Minimum Permanent Flue Opening (sq. ins.) 6' to 15' 15' to 30'39 sq. inches 29 sq. inches
Area of Various Standard Round Flues Diameter (ins.)Area (sq. ins.) 5" 6" 7" 8"20 sq. inches 29 sq. inches 39 sq. inches 51 sq. inches

If your heater is a manually controlled model, you may use this heater as a vented product. There are three reasons for operating your heater in the vented mode. 1. The fireplace does not meet the clearance to combustibles requirements for vent-free operation. 2. State or local codes do not permit vent- free operation. 3. You prefer vented operation.

INSTALLING HEATER BASE ASSEMBLY

If reasons number 1 or 2 above apply to you, you must permanently open chimney flue damper. You must install the damper clamp accessory (to order, see Accessories, page 28). This will insure vented operation (see Figure 10). The damper clamp will keep damper open. Installation instructions are included with clamp accessory.

Manufactured Fireplace Masonry Fireplace

Figure 10 - Attaching Damper Clamp

Show 5 more labels / short text on this page
Damper Clamp Damper · Damper Clamp · Damper · Damper · 10 103425
Page 11 of the Desa Tech CGG3630P user manual — INSTALLATION
Page 11 · click to enlarge
Page 11

INSTALLATION

  • Installation Items Needed
  • hardware package (provided with heater)
  • approved flexible gas hose (not provided) (if allowed by local codes)
  • sealant (resistant to propane/LP gas, not provided)
  • electric drill with 3/16" masonry drill bit 1. Apply pipe joint sealant lightly to male threads of gas connector and install into regulator. Connect approved flexible gas hose to gas regulator of heater (see Figure 11). IMPORTANT: Hold gas regulator with wrench when connecting fittings. 2. Position heater base assembly in fireplace. 3. Mark screw locations through holes in front of base. If installing in a brickbottom fireplace, mark screw locations in mortar joint of bricks. 4. Remove heater base from fireplace. 5. Drill holes at marked locations using 3/16" drill bit. Drill at a 45° angle. 6. Attach base to fireplace floor using masonry screws in hardware package (see Figure 12). 7. Connect to gas supply. See Connecting To Gas Supply, page 12.

Flexible Gas Hose (if allowed by local codes)

Figure 11 - Attaching Flexible Gas Hose to Heater Gas Regulator

Figure 12 - Attaching Heater to Fireplace Floor

Show 4 more labels / short text on this page
Heater Gas Regulator · Masonry Screw · Continued · 11 103425
Page 12 of the Desa Tech CGG3630P user manual — Installation Items Needed
Page 12 · click to enlarge
Page 12

INSTALLATION

Installation must include a manual shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 14).

CONNECTING TO GAS SUPPLY

Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves.

Install sediment trap in supply line as shown in Figure 14. Locate sediment trap where it is within reach for cleaning. Locate sedi- ment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into heater controls. If sediment trap is not installed or is installed wrong, heater may not run properly.

Figure 13 - External Regulator With Vent Pointing Down

Installation Items Needed

  • Before installing heater, make sure you have the items listed below.
  • external regulator (supplied by installer)
  • piping (check local codes)
  • sealant (resistant to propane/ LP gas)
  • manual shutoff valve *
  • test gauge connection *
  • sediment trap
  • tee joint
  • pipe wrench

* An CSA design-certified manual shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Pur- chase the optional CSA design-certified manual shutoff valve from your dealer. See Accessories, page 28.

CSA Design-Certified Manual Shutoff Valve With 1/8" NPT Tap*

From External Regulator (11" W.C.** to 14" W.C. Pressure)

Approved Flexible Gas Hose (if allowed by local codes)

The installer must supply an external regu- lator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incom- ing gas pressure, heater regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure 13. Pointing the vent down protects it from freezing rain or sleet.

Figure 14 - Gas Connection * Purchase the optional CSA design-certified manual shutoff valve from your dealer. See Accessories, page 28. ** Minimum inlet pressure for purpose of input adjustment.

Show 10 more labels / short text on this page
Propane/LP Supply Tank · External Regulator · Vent Pointing Down · Tee Joint · Pipe Nipple · 3" Minimum · Cap · Gas Regulator · Sediment Trap · 12 103425
Page 13 of the Desa Tech CGG3630P user manual — Pressure Testing Gas Supply Piping System
Page 13 · click to enlarge
Page 13

INSTALLATION Continued

Test Pressures Equal To or Less Than 1/2 PSIG 1. Close manual shutoff valve (see Fig- ure 15). 2. Pressurize supply piping system by ei- ther using compressed air or opening propane/LP supply tank valve. 3. Check all joints from propane/LP sup- ply tank to manual shutoff valve (see Figure 16). Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak. 4. Correct all leaks at once.

Pressure Testing Heater Gas Connections 1. Open manual shutoff valve (see Fig- ure 15). 2. Open propane/LP supply tank valve. 3. Make sure control knob of heater is in the OFF position. 4. Check all joints from manual shutoff valve to thermostat gas valve (thermo- stat-controlled models) or control valve (variably-controlled models) (see Fig- ure 16). Apply mixture of liquid soap and water to gas joints. Bubbles form- ing show a leak. 5. Correct all leaks at once. 6. Light heater (see Operating Heater, pages 15 and 16 [Thermostat- Controlled Models] or pages 16 and 17 [Variable Manually- Controlled Models]). Check all other internal joints for leaks. 7. Turn off heater (see To Turn Off Gas to Appliance, page 16 [Thermostat-Con- trolled Models] or page 17 [Variable Manually-Controlled Models]).

CHECKING GAS CONNECTIONS

ON POSIT

O PO

Figure 15 - Manual Shutoff Valve

Pressure Testing Gas Supply Piping System

Test Pressures In Excess Of 1/2 PSIG 1. Disconnect heater and its individual manual shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig will damage heater regulator. 2. Cap off open end of gas pipe where manual shutoff valve was connected. 3. Pressurize supply piping system by ei- ther using compressed air or opening propane/LP supply tank valve. 4. Check all joints of gas supply piping system. Apply mixture of liquid soap and water to gas joints. Bubbles form- ing show a leak. 5. Correct all leaks at once. 6. Reconnect heater and manual shutoff valve to gas supply. Check re- connected fittings for leaks.

Thermostat Gas Valve or Control Valve Location

Figure 16 - Checking Gas Joints

Show 7 more labels / short text on this page
Manual Shutoff Valve · Open · Closed · Manual Shutoff Valve · Propane/LP Supply Tank · Continued · 13 103425
Page 14 of the Desa Tech CGG3630P user manual — INSTALLING LOGS
Page 14 · click to enlarge
Page 14

INSTALLATION Continued

INSTALLING LOGS

Each log is marked with a number. These numbers will help you identify the log when installing. It is very important to install these logs exactly as instructed. Do not modify logs. Only use logs supplied with heater. 1. Slide rear log (#1) into place behind rear burner. Make sure flat areas at bot- tom of log are behind front burner (see Figure 17). 2 . Slide bottom mid log (#2) into place in behind front burner. Make sure tabs at bottom of log are behind rear burner (see Figure 18). 3. Place front log (#3) into place in front of bottom mid log (#2) (see Figure 19). Make sure notches on bottom rest on grate prongs. 4. Finally place top log (#4) over bottom mid log (#2) by matching the notches under log (#4) with the raised blocks of log (#2) (see Figure 20).

Figure 19 - Installing Front Log

Figure 17 - Installing Rear Log

Bottom Mid Log (#2)

Figure 20 - Installing Top Log

Figure 18 - Installing Bottom Mid Log

Show 5 more labels / short text on this page
Front Log (#3) · Rear Log (#1) · Top Log (#4) · Tab · 14 103425
Page 15 of the Desa Tech CGG3630P user manual — HI
Page 15 · click to enlarge
Page 15

OPERATING HEATER Thermostat-Controlled Models

LIGHTING INSTRUCTIONS

4. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information, column 1. If you don’t smell gas, go to the next step. 5. Turn control knob counterclockwise
  • WARNING:
  • If fireplace has glass doors, never operate this heater with glass doors closed. If you operate heater with doors closed, heat buildup inside fireplace will cause glass to burst. Also if fireplace opening has vents at the bottom, you must open the vents before operating heater.
  • You must operate this heater with a fireplace screen in place. Make sure fireplace screen is closed before running heater.

FOR YOUR SAFETY

READ BEFORE

to the PILOT position. Press in control knob for five (5) seconds (see Figure 21). • If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs. Note: You may be running this heater for the first time after hook- ing up to gas supply. If so, the con- trol knob may need to be pressed in for 30 seconds or less. This will allow air to bleed from the gas system. 6. With control knob pressed in, press and release ignitor button. This will light pilot. The pilot is attached to the front burner. If needed, keep pressing igni- tor button until pilot lights. Note: If pilot does not stay lit, con- tact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Light- ing Procedure, page 16. 7. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Note: If pilot goes out, repeat steps 3 through 7. This heater has a safety interlock system. Wait one (1) minute for system to reset before lighting pilot again. 8. Turn control knob counterclockwise

LIGHTING

  • A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. WHAT TO DO IF YOU SMELL GAS
  • Do not try to light any appliance.
  • Do not touch any electric switch; do not use any phone in your building.
  • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
  • If you cannot reach your gas supplier, call the fire department. C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician or gas supplier. Force or attempted repair may result in a fire or explosion. D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

Note: Home owners generally prefer to operate their heater with the chimney damper closed. This will put all the heat into the room. However, there may be times you will desire the full flames of the Hi heat setting but will find the heat output excessive. You can open the chim- ney damper (if you have one) fully or partially to release some of the heat.

to desired heating level. The burners should light. Set control knob to any heat level between HI and LO.

1. STOP! Read the safety information in column 1. 2. Make sure manual shutoff valve is fully open. 3. Turn control knob clockwise to the OFF position.

HI

PILOT

OFF

LO

Control Knob Ignitor Button

Figure 21 - Control Knob and Ignitor Button Location

Figure 22 - Pilot

Show 4 more labels / short text on this page
Thermocouple Ignitor Electrode · Pilot Burner · Continued · 15 103425
Page 16 of the Desa Tech CGG3630P user manual — HI
Page 16 · click to enlarge
Page 16

Variable Manually-Controlled Models OPERATING HEATER Continued

LIGHTING INSTRUCTIONS

FOR YOUR SAFETY READ BEFORE LIGHTING

  • WARNING:
  • If fireplace has glass doors, never operate this heater with glass doors closed. If you operate heater with doors closed, heat buildup inside fireplace will cause glass to burst. Also if fireplace opening has vents at the bottom, you must open the vents before operating heater.
  • You must operate this heater with a fireplace screen in place. Make sure fireplace screen is closed before running heater. THERMOSTAT CONTROL OPERATION

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

Turn control knob clockwise to the OFF position.

Shutting Off Burners Only (pilot stays lit)

  • A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. WHAT TO DO IF YOU SMELL GAS
  • Do not try to light any appliance.
  • Do not touch any electric switch; do not use any phone in your building.
  • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
  • If you cannot reach your gas supplier, call the fire department. C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician or gas supplier. Force or attempted repair may result in a fire or explosion. D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

Turn control knob clockwise to the PILOT position.

(Thermostat-Controlled

Models Only)

The thermostat control knob can be set to any comfort level between Hi and Lo. The thermostat will gradually modulate the heat output and flame height from higher to lower settings, or pilot, in order to maintain the comfort level you select. The ideal comfort setting will vary by household depending upon the amount of space to be heated, the output of the central heating system, etc.

Note: Home owners generally prefer to operate their heater with the chimney damper closed. This will put all the heat into the room. However, there may be times you will desire the full flames of the High heat setting but will find the heat output excessive. You can open the chim- ney damper (if you have one) fully or partially to release some of the heat.

MANUAL LIGHTING

PROCEDURE 1. Follow steps 1 through 5 under Light- ing Instructions, page 15. 2. Depress control knob and light pilot with match. 3. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow step 8, page 15.

1. STOP! Read the safety information column 2. 2. Make sure manual shutoff valve is fully open. 3. Press in and turn control knob clockwise Clockwise to the OFF position.

HI

PILOT

OFF

LO

Control Knob Ignitor Button

Figure 23 - Control Knob and Ignitor Button Location

16 103425

Page 17 of the Desa Tech CGG3630P user manual — MANUAL LIGHTING
Page 17 · click to enlarge
Page 17

OPERATING HEATER Continued

VARIABLE CONTROL

INSPECTING BURNERS

OPERATION

The variable control valve can be set to any heat setting and flame height desired between high and low by simply turning the control knob until that setting is at- tained. Even the lowest setting provides realistic flames and glowing embers from two burners. Selecting higher settings pro- duces greater heat output. This results in increased heating comfort.

Check pilot flame pattern and burner flame patterns often.

4. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety in- formation, page 16. If you don’t smell gas, go to the next step. 5. Press in control knob and turn counter- clockwise C-clockwise to the PILOT posi- tion. Keep control knob pressed in for five (5) seconds (see Figure 23, page 16). • If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs. Note: You may be running this heater for the first time after hook- ing up to gas supply. If so, the con- trol knob may need to be pressed in for 30 seconds. This will allow air to bleed from the gas system. 6. With control knob pressed in, press and release ignitor button. This will light pilot. The pilot is attached to the front burner. If needed, keep pressing igni- tor button until pilot lights. Note: If pilot does not light, contact a qualified service person or gas sup- plier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure. 7. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Note: If pilot goes out, repeat steps 3 through 7. 8. Push in and turn control knob coun- terclockwise C-clockwise to the HIGH position. Both burners should light. Set control knob to desired setting.

PILOT FLAME PATTERN

Figure 25 shows a correct pilot flame pattern. Figure 26 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touch- ing the thermocouple. This will cause the thermocouple to cool. When the thermo- couple cools, the heater will shut down.

  • If pilot flame pattern is incorrect, as shown in Figure 26
  • turn heater off (see To Turn Off Gas to Appliance, page 16 [Thermostat-Controlled Models] or page 17 or [Variable Manually-Controlled Models])
  • see Troubleshooting , pages 19 through 21

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater 1. Press in and turn control knob clock- wise Clockwise to the HIGH position. 2. Turn the control knob clockwise

Clockwise to the PILOT position. 3. Press in control knob and turn clock- wise Clockwise to the OFF Position.

Figure 25 - Correct Pilot Flame Pattern

Shutting Off Burners Only (pilot stays lit) 1. Turn the control knob clockwise

Clockwise to the HIGH position. 2. Press in and turn control knob clock- wise Clockwise to the pilot position.

MANUAL LIGHTING

PROCEDURE 1. Follow steps 1 through 5 under Light- ing Instructions, page 16. 2. Depress control knob and light pilot with match. 3. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow step 8, column 1.

Figure 26 - Incorrect Pilot Flame Pattern

Figure 24 - Pilot

Show 7 more labels / short text on this page
Thermocouple · Pilot Burner · Pilot Burner Thermocouple · Thermocouple Ignitor Electrode · Pilot Burner · Continued · 17 103425
Page 18 of the Desa Tech CGG3630P user manual — CLEANING BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLE
Page 18 · click to enlarge
Page 18

INSPECTING BURNERS Continued

CLEANING AND MAINTENANCE

4. Check the injector holder located at the end of the burner tube again. Remove any large particles of dust, dirt, lint, or pet hairs with a soft cloth or vacuum cleaner nozzle. 5. Blow air into the primary air holes on the injector holder. 6. In case any large clumps of dust have now been pushed into the burner repeat steps 3 and 4.
Desa Tech CGG3630P — INSPECTING BURNERS Continued diagram (page 18)
Fig. 1 · INSPECTING BURNERS Continued

FRONT BURNER FLAME PATTERN

Figure 27 shows correct front burner flame pattern. Figure 28 shows incorrect front burner flame pattern. The incorrect burner flame pattern shows yellow tipping at top of blue flame.

Clean the pilot assembly also. A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly. There is a small pilot air inlet hole about two inches from where the pilot flame comes out of the pilot assembly (see Figure 30). With the unit off, lightly blow air through the air inlet hole. You may blow through a drinking straw if compressed air is not available.

Desa Tech CGG3630P — FRONT BURNER FLAME PATTERN diagram (page 18)
Fig. 2

CLEANING BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLE

Desa Tech CGG3630P — CLEANING BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLE diagram (page 18)
Fig. 3

The primary air inlet holes allow the proper amount of air to mix with the gas. This provides a clean burning flame. Keep these holes clear of dust, dirt, and lint. Clean these air inlet holes prior to each heating season. Blocked air holes will create soot. We rec- ommend that you clean the unit every 2,500 hours of operation or every three months.

  • If front burner flame pattern is incorrect, as shown in Figure 28
  • turn heater off (see To Turn Off Gas to Appliance, page 16 [Thermostat-Controlled Models] or page 17 [Variable Manually-Controlled Models])
  • see Troubleshooting , pages 19 through 21

We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt. To clean these parts we recom- mend using compressed air no greater than 30 PSI. Your local computer store, hard- ware store, or home center may carry com- pressed air in a can. You can use a vacuum cleaner in the blow position. If using com- pressed air in a can, please follow the direc- tions on the can. If you don't follow direc- tions on the can, you could damage the pilot assembly. 1. Shut off the unit, including the pilot. Allow the unit to cool for at least thirty minutes. 2. Inspect burner, pilot, and primary air inlet holes on injector holder for dust and dirt (see Figure 29). 3. Blow air through the ports/slots and holes in the burner.

Figure 29 - Injector Holder On Outlet Burner Tube

Figure 27 - Correct Front Burner Flame Pattern Yellow Tipping At Top of Blue Flame

  • LOGS
  • If you remove logs for cleaning, refer to Installing Logs, page 14, to properly replace logs.
  • Replace log(s) if broken or chipped (dime-sized or larger).

Figure 28 - Incorrect Front Burner Flame Pattern

Injector Holder · 18 103425

Page 19 of the Desa Tech CGG3630P user manual — OBSERVED PROBLEM
Page 19 · click to enlarge
Page 19

TROUBLESHOOTING WARNING: Turn off and un- plug heater and let cool before servicing. Only a qualified ser- vice person should service and repair heater.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

When ignitor button is pressed, there is no spark at ODS/pilot

1. Ignitor electrode not connected to ignitor cable 2. Ignitor cable pinched or wet
1. Reconnect ignitor cable
2. Free ignitor cable if pinched by any metal or tubing. Keep ignitor cable dry 3. Tighten nut holding piezo ignitor to base panel of log set. Nut is located behind base panel. 4. Replace ignitor cable 5. Replace piezo ignitor 6. Replace piezo ignitor 7. Replace piezo ignitor
3. Piezo ignitor nut is loose
4. Broken ignitor cable 5. Bad piezo ignitor 6. Ignitor electrode broken 7. Ignitor electrode positioned wrong

When ignitor button is pressed, there is spark at ODS/pilot but no ignition

1. Gas supply turned off or manual shutoff valve closed 2. Control knob not in PILOT position 3. Control knob not pressed in while in PILOT position 4. Air in gas lines when installed
1. Turn on gas supply or open manual shutoff valve 2. Turn control knob to PILOT position 3. Press in control knob while in PILOT position 4. Continue holding down control knob. Repeat igniting operation until air is removed 5. Contact local propane/LP gas company 6. Clean ODS/pilot (see Cleaning and Maintenance , page 18) or replace ODS/ pilot assembly 7. Replace gas regulator
5. Depleted gas supply 6. ODS/pilot is clogged
7. Gas regulator setting is not correct

ODS/pilot lights but flame goes out when control knob is released

1. Control knob not fully pressed in 2. Control knob not pressed in long enough
1. Press in control knob fully 2. After ODS/pilot lights, keep control knob pressed in 30 seconds 3. Wait one minute for safety interlock system to reset. Repeat ignition operation 4. Fully open manual shut-off valve 5. A) Contact local propane/LP gas company
3. Safety interlock system has been triggered (thermostat models only) 4. Manual shutoff valve not fully open 5. Pilot flame not touching thermocouple, which allows thermocouple to cool, causing pilot flame to go out. This problem could be caused by one or both of the following: A) Low gas pressure B) Dirty or partially clogged ODS/pilot 6. Thermocouple connection loose at control valve 7. Thermocouple damaged 8. Control valve damaged

B) Clean ODS/pilot (see Cleaning and Maintenance, page 18) or replace ODS/ pilot assembly

6. Hand tighten until snug, then tighten 1/4 turn more 7. Replace thermocouple 8. Replace control valve

www.desatech.com Continued

19 103425

Page 20 of the Desa Tech CGG3630P user manual — OBSERVED PROBLEM
Page 20 · click to enlarge
Page 20

TROUBLESHOOTING Continued

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

One or both burners do not light after ODS/ pilot is lit

1. Burner orifice(s) clogged
1. Clean burner(s) (see Cleaning and Maintenance , page 18) or replace burner orifice(s) 2. Contact local propane/LP gas company 3. Contact qualified service person 4. Replace burner orifice(s)
2. Inlet gas pressure is too low 3. Mislocated crossover tube 4. Burner orifice(s) diameter is too small

Delayed ignition of one or both burners

1. Manifold pressure is too low 2. Burner orifice(s) clogged
1. Contact local propane/LP gas company 2. Clean burner(s) (see Cleaning and Maintenance , page 18) or replace burner orifice(s) 3. Contact qualified service person
3. Mislocated crossover tube

Burner backfiring during combustion

1. Burner orifice is clogged or damaged
1. Clean burner (see Cleaning and Maintenance , page 18) or replace burner orifice 2. Replace damaged burner 3. Replace gas regulator
2. Damaged burner 3. Gas regulator defective

Yellow flame in front burner during burner combustion

1. Not enough air
1. Check burner(s) for dirt and debris. If found, clean burner(s) (see Cleaning and Maintenance , page 18) 2. Replace gas regulator
2. Gas regulator defective

Slight smoke or odor during initial operation

1. Residues from manufacturing processes and logs curing
1. Problem will stop after a few hours of operation

Moisture/condensation noticed on windows

1. Not enough combustion/ventilation air
1. Refer to Air for Combustion and Ventilation requirements (page 4)

Heater produces a whistling noise when burners are lit

1. Turning control knob to HI position when burners are cold 2. Air in gas line
1. Turn control knob to LO position and let warm up for a minute 2. Operate burners until air is removed from line. Have gas line checked by local propane/LP gas company 3. Observe minimum installation clearances (see pages 7 through 9) 4. Clean burners (see Cleaning and Maintenance , page 18) or replace burner orifice(s)
3. Air passageways on heater blocked
4. Dirty or partially clogged burner orifice(s)

White powder residue forming within burner box or on adjacent walls or furniture

1. When heated, vapors from furniture polish, wax, carpet cleaners, etc. turn into white powder residue
1. Turn heater off when using furniture polish, wax, carpet cleaners, or similar products

www.desatech.com

20 103425

Page 21 of the Desa Tech CGG3630P user manual — OBSERVED PROBLEM
Page 21 · click to enlarge
Page 21

TROUBLESHOOTING Continued

  • WARNING: If you smell gas
  • Shut off gas supply.
  • Do not try to light any appliance.
  • Do not touch any electrical switch; do not use any phone in your building.
  • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
  • If you cannot reach your gas supplier, call the fire department.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Heater produces a clicking/ticking noise just after burners are lit or shut off

1. Metal expanding while heating or contracting while cooling
1. This is common with most heaters. If noise is excessive, contact qualified service person

Heater produces unwanted odors

1. Heater burning vapors from paint, hair spray, glues, cleaners, chemicals, new carpet, etc. (See IMPORTANT statement above) 2. Low fuel supply 3. Gas leak. See Warning statement at top of page
1. Open window to ventilate room. Stop using odor causing products while heater is running
2. Refill supply tank 3. Locate and correct all leaks (see Checking Gas Connections , page 13)

Heater shuts off in use (ODS operates)

1. Not enough fresh air is available 2. Low line pressure 3. ODS/pilot is partially clogged
1. Open window and/or door for ventilation 2. Contact local propane/LP gas company 3. Clean ODS/pilot (see Cleaning and Maintenance , page 18)

Gas odor even when control knob is in OFF position

1. Gas leak. See Warning statement at top of page 2. Control valve defective
1. Locate and correct all leaks (see Checking Gas Connections , page 13) 2. Replace control valve

Gas odor during combustion

1. Foreign matter between control valve and burner 2. Gas leak. See Warning statement at top of page
1. Take apart gas tubing and remove foreign matter 2. Locate and correct all leaks (see Checking Gas Connections , page 13)
1. Reposition thermostat sensing bulb (see Instructions for Optional Positioning of Thermostat Sensing Bulb, page 23)

Log set cycles to pilot, but room tempera- ture drops to a lower than ideal level before log set comes back on

1. Thermostat sensing bulb needs to be repositioned

www.desatech.com

21 103425

Page 22 of the Desa Tech CGG3630P user manual — Q
Page 22 · click to enlarge
Page 22

OPTIONAL POSITIONING OF THERMOSTAT SENSING BULB

4. The mounting clip must be a minimum of 3" from bottom of fireplace to pre- vent crimping of capillary. Once you have decided on a location, clean the area thoroughly. Remove the paper backing from the adhesive on back of mounting clip. Press the clip into the new location so that the thermostat sensing bulb will be positioned vertically with the capillary at the bot- tom (see Figure 37). Slide the thermo- stat sensing bulb into the clip. IMPORTANT: Do not crimp capillary.

FOR MASONRY AND FACTORY-BUILT METAL FIREPLACE

Figure 34 - Locating Thermostat Sensing Bulb on Masonry Fireplace

Q

If your log set cycles to pilot, but the room temperature drops to a lower than ideal comfort level before the log set comes back on, you may want to reposition the thermostat sensing bulb.

Q

The thermostat sensing bulb is located on the gas valve assembly. This location al- lows the thermostat to keep the room tem- perature at an ideal comfort level for most fireplace applications. For positioning the thermostat sensing bulb elsewhere, an adhe- sive-backed mounting clip is available.

Q

Q

Figure 35 - Locating Thermostat Sensing Bulb on Factory-built Metal Fireplace

Q

Q

Tools needed• 5/16" hex driver or socket

1. Locate the gas valve assembly and ther- mostat sensing bulb (see Figure 31). 2. With 5/16" hex driver or socket, loosen the thermostat screw. Carefully slide the thermostat sensing bulb out of the retaining clamp (see Figure 33). Note: Do not remove the screw. Make sure you tighten the screw after remov- ing the thermostat sensing bulb. IMPORTANT: Do not force or bend the thermostat sensing bulb or capillary. A crimped capillary will not allow ther- mostat to operate properly. It cannot be repaired, the valve must be replaced. 3. The thermostat sensing bulb may be located to the lower right front side of fireplace. Determine location of sens- ing bulb, but do not mount sensing bulb until step 5. If you have a masonry fire- place, see Figure 34 for location. If you have a factory-built metal fire- place, see Figure 35 for location. If your fireplace has glass doors, posi- tion sensing bulb directly behind door gap on right bottom side (see Figure 36).

Q

Q

Figure 31 - Location of Gas Valve Assembly and Thermostat Sensing Bulb

Q

Q

Adhesive- backed Mounting Clip Glass Doors

Q

Q ¢

Q

Figure 32 - Adhesive-backed Mounting Clip

Figure 36 - Installing Thermostat Sensing Bulb behind Glass Doors

Thermostat Sensing Bulb Screw

Do Not Crimp Capillary

Figure 33 - Removing Thermostat Sensing Bulb

Figure 37 - Positioning the Thermostat Sensing Bulb in the Vertical Position with the Capillary at the Bottom

Show 34 more labels / short text on this page
Thermostat Sensing Bulb · Adhesive-backed Mounting Clip · · Thermostat Sensing Bulb · · ¢ · · ¢ · Adhesive- backed Mounting Clip · · ¢ · · ¢ · · ¢ · Gas Valve Assembly · Thermostat Sensing Bulb · Thermostat Sensing Bulb · · ¢ · · ¢ · · ¢ · · ¢ · · ¢ · Capillary · Thermostat Sensing Bulb · Adhesive- backed Mounting Clip · Capillary · Retaining Clamp · 22 103425
Page 23 of the Desa Tech CGG3630P user manual — PARTS NOT UNDER WARRANTY
Page 23 · click to enlarge
Page 23

SPECIFICATIONS

Model CGG3324PT CGG2618P CGG3324P CGG3630P

Btu (Variable) 20,000/33,000 16,000/26,000 20,000/33,000 21,500/36,000

Type Gas Propane/LP Only Propane/LP Only Propane/LP Only Propane/LP Only

Ignition Piezo

Manifold Pressure 7.9" W.C. 7.9" W.C. 7.9" W.C. 7.9" W.C.

Inlet Gas Pressure (in. of water)

Maximum 14" Minimum* 11"

Shipping Weight 38 lbs. 36 lbs. 38 lbs. 40 lbs.

* For purpose of input adjustment

SERVICE HINTS

REPLACEMENT PARTS

  • When Gas Pressure Is Too Low
  • pilot will not stay lit
  • burners will have delayed ignition
  • heater will not produce specified heat
  • propane/LP gas supply may be low

PARTS UNDER WARRANTY

  • When Gas Quality Is Bad
  • pilot will not stay lit
  • burners will produce flames and soot
  • heater will backfire when lit

Contact authorized dealers of this product. If they can’t supply original replacement part(s), call DESA International’s Techni- cal Service Department at 1-800-323-5190.

  • When calling DESA International, have ready
  • your name
  • your address
  • model and serial numbers of your heater
  • how heater was malfunctioning
  • type of gas used (propane/LP or natural gas)
  • purchase date

You may feel your gas pressure is too low or gas quality is bad. If so, contact your local propane/LP gas supplier.

TECHNICAL SERVICE

You may have further questions about in- stallation, operation, or troubleshooting.

Usually, we will ask you to return the defec- tive part to the factory.

If so, contact DESA International’s Techni- cal Service Department at 1-800-DESA LOG (1-800-337-2564).

PARTS NOT UNDER WARRANTY

You can also visit DESA International’s Technical Service web site at www.desatech.com

Contact authorized dealers of this product. If they can’t supply original replacement part(s), either contact your nearest Parts Central (see page 28) or call DESA International’s Parts Department at 1-800-972-7879 for referral information.

  • When calling DESA International, have ready
  • model number of your heater
  • the replacement part number

23 103425

Page 24 of the Desa Tech CGG3630P user manual — VARIABLE MANUALLYCONTROLLED MODELS
Page 24 · click to enlarge
Page 24

ILLUSTRATED PARTS BREAKDOWN

Desa Tech CGG3630P — ILLUSTRATED PARTS BREAKDOWN diagram (page 24)
Fig. 4

VARIABLE MANUALLYCONTROLLED MODELS

CGG2618P CGG3324P CGG3630P

24 103425

Page 25 of the Desa Tech CGG3630P user manual — PARTS AVAILABLE — NOT SHOWN
Page 25 · click to enlarge
Page 25

PARTS LIST

This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 23 of this manual.

VARIABLE MANUALLYCONTROLLED MODELS

CGG2618P CGG3324P CGG3630P

KEY PART NUMBER FOR NO. CGG2618P CGG3324P CGG3630P DESCRIPTION QTY.

1 103681-04 103682-04 103683-04 Rear Log (#1) 1 2 103681-02 103682-02 103683-02 Bottom Mid Log (#2) 1 3 103681-01 103682-01 103683-01 Front Log (#3) 1 4 103681-03 103682-03 103683-03 Top Log (#4) 1 5 098249-01 098249-01 098249-01 Nut 4 6 101006-01 101006-01 101006-01 Pilot Bracket 1 7 101330-01 101330-05 101330-06 Front Burner Assembly 1 7-1 101008-01 101008-01 101008-01 Crossover Burner Gasket 1 7-2 101007-01 101007-01 101007-01 Crossover Burner 1 8 100999-01 100999-02 100999-03 Rear Burner Assembly 1 9 101331-10 101331-08 101331-09 Base Assembly (Includes Decals) 1 10 098271-07 098271-06 098271-06 Ignitor Cable 1 11 102445-01 102445-01 102445-01 Piezo Ignitor 1 12 098867-10 098867-10 098867-10 Gas Regulator 1 13 M11084-38 M11084-38 M11084-38 Screw 2 14 101011-01 101011-02 101011-03 Inlet Tube 1 15 098354-01 098354-01 098354-01 Control Knob 1 16 098462-03 098462-03 098462-03 Control Rod 1 17 098325-01 098325-01 098325-01 Roll Pin 1 18 098508-01 098508-01 098508-01 Valve Retainer Nut 1 19 102568-02 102568-02 102568-02 Gas Valve 1 20 101005-01 101005-01 101005-01 Valve Bracket 1 21 M11084-26 M11084-26 M11084-26 Screw 4 22 101004-10 101004-01 101004-02 Rear Burner Injector 1 23 101004-10 101004-02 101004-06 Front Burner Injector 24 102258-01 102258-01 102258-01 Burner Tube 1 25 099387-08 099387-08 099387-08 Pilot Tube 1 26 098276-01 098276-01 098276-01 1/8” Plug 1 27 099059-02 099059-02 099059-02 O.D.S. Pilot 1 27-1 098594-01 098594-01 098594-01 Ignitor Electrode 1 27-2 098593-01 098593-01 098593-01 Thermocouple 1

PARTS AVAILABLE — NOT SHOWN

100563-01 100563-01 100563-01 Warning Plate 1 101054-01 101054-01 101054-01 Lighting Instructions Plate 1 100565-01 100565-01 100565-01 Warning Plate Fastener 1 100639-01 100639-01 100639-01 Caution Decal 1 101137-03 101137-03 101137-03 Hardware Kit 1 101416-28 101416-28 101416-28 Information Video 1 GA6060 GA6060 GA6060 Lava Rock 1

25 103425

Page 26 of the Desa Tech CGG3630P user manual — SPECIFICATIONS
Page 26 · click to enlarge
Page 26
Desa Tech CGG3630P — SPECIFICATIONS diagram (page 26)
Fig. 5

26 103425

Page 27 of the Desa Tech CGG3630P user manual — PARTS AVAILABLE — NOT SHOWN
Page 27 · click to enlarge
Page 27

PARTS LIST

This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 23 of this manual.

THERMOSTATCONTROLLED MODEL

KEY PART NO. NUMBER DESCRIPTION QTY.

CGG3324PT

1 103682-04 Rear Log (#1) 1 2 103682-02 Bottom Mid Log (#2) 1 3 103682-01 Front Log (#3) 1 4 103682-03 Top Log (#4) 1 5 102764-01 Heat Shield 1 6 M11084-26 Screw 5 7 099059-02 O.D.S. Pilot 1 7-1 098594-01 Ignitor 1 7-2 098593-01 Thermocouple 1 8 098249-01 Nut 4 9 101006-01 Pilot Bracket 1 10 101330-05 Front Burner Assembly 1 10-1 101008-01 Gasket, Crossover Burner 1 10-2 101007-01 Crossover Burner 1 11 100999-02 Rear Burner Assembly 1 12 101331-08 Base Assembly (with decals) 1 13 098271-06 Ignitor Cable 1 14 102445-01 Piezo Ignitor 1 15 098867-10 Gas Regulator 1 16 M11084-38 Screw 2 17 102810-02 Inlet Tube 1 18 098354-01 Control Knob 1 19 102013-01 Control Rod 1 20 100000-01 Cotter Pin 1 21 101053-01 Adapter 1 22 099211-01 Screw 1 23 098544-01 Thermostat Clamp 1 24 101329-18 Thermostat Gas Valve Assy. 1 25 100994-01 Thermovalve Bracket 1 26 101004-01 Rear Burner Injector 1 27 101004-02 Front Burner Injector 1 28 102811-01 Thermostat Burner Tube 1 29 099387-09 Pilot Tube 1 30 102255-01 Strap

PARTS AVAILABLE — NOT SHOWN

100563-01 Warning Plate 1 101054-01 Lighting Instructions Plate 1 100565-01 Warning Plate Fastener 1 100639-01 Caution Decal 1 101137-03 Hardware Kit 1 101416-28 Information Video 1 GA6060 Lava Rock 1

27 103425

Page 28 of the Desa Tech CGG3630P user manual — LAVA ROCK - GA6060 (Not Shown)
Page 28 · click to enlarge
Page 28

PARTS CENTRALS

East Coast Energy Products 707 Broadway W. Long Branch, NJ 07764 908-870-8809 1-800-755-8809 Parts Department

ACCESSORIES

These Parts Centrals are privately owned busi- nesses. They have agreed to support our customer’s needs by providing original replace- ment parts and accessories. When calling a Parts Central, ask for the Parts Department.

Purchase these heater accessories from your local dealer. If they can not supply these accessories, call DESA International’s Parts Department at 1-800-972-7879 for infor- mation. You can also write to the address listed on the back page of this manual.

Baltimore Electric 1348 Dixwell Avenue Hamden, CT 06514 1-800-397-7553 203-248-7553 Parts Department

Tarantin Tank Co. P.O. Box 6129 Freehold, NJ 07728 908-780-9340 1-800-922-0724 Parts Department

Albany Ladder 1586-90 Central Avenue Albany, NY 07728 NY, MA, VT 1-800-354-7368 518-869-5335 Parts Department

Portable Heater Parts 342 N. County Rd. 400 East Valparaiso, IN 46383 All States 219-462-7441 1-800-362-6951 Parts Department

MANUAL SHUTOFF VALVE GA5010

For all models. Manual shutoff valve with 1/8" NPT tap. Fits 1/2" NPT pipe.

F B D P. O. Box 1096 1720 Kummer Road Franklin, KY 42134 502-586-1922 1-800-654-8534

Dayton Hardware P.O. Box 275 North Dayton Station Dayton, OH 45404 All States 513-258-3721 OH 1-800-762-3426 Parts Department

FIREPLACE HOOD Black - GA6050 Brass - GA6052

Four Flags Power Products 1115 Stateline Road Niles, MI 49120 616-684-2697 Parts Only

Halco Enterprises 208 Carter Drive, Unit 21 West Chester, PA 19382 610-430-7717 US 1-800-368-0803 Parts Department

For all models. Helps deflect heat away from mantel or wall above fireplace.

DAMPER CLAMP - GA6080 (Not Shown)

Master Parts Distributors 1184 Wilson Ave. NW Walker, MI 49504 616-791-0505 US 1-800-446-1446 Fax: 616-791-8270 Parts Department

For variably controlled models. Permanently opens chimney flue damper for vented op- eration. Can be used only with non-thermo- stat accessories.

LA Porte's Parts & Service 2444 North 5th Street Hartsville, SC 29550 803-332-0191 Parts Department

LAVA ROCK - GA6060 (Not Shown)

Washer Equipment Co. 1715 Main Street Kansas City, MO 64108 KS, MO, AR 816-842-3911 Parts Department

For all models. Order when additional rock is desired. (3 lb. bag)

Cans Unlimited, Inc. P.O. Box 645 Taylor, SC 29687 All States 803-879-3009 1-800-845-5301 Parts Department

28 103425

Page 29 of the Desa Tech CGG3630P user manual — NOTES
Page 29 · click to enlarge
Page 29

NOTES

Show 35 more labels / short text on this page
_______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · 29 103425
Page 30 of the Desa Tech CGG3630P user manual — NOT A UPC
Page 30 · click to enlarge
Page 30

WARRANTY INFORMATION

KEEP THIS WARRANTY

Serial No.

Always specify model and serial numbers when communicating with the factory.

We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied.

LIMITED WARRANTY COMFORT GLOW VENT-FREE PROPANE/LP GAS LOG HEATERS

DESA International warrants this product to be free from defects in materials and components for two (2) years from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions. To make a claim under this warranty the Bill of Sale or cancelled check must be presented.

This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required to restore this heater to proper operating condition and an allowance for labor when provided by a DESA Authorized Service Center. Warranty part(s) MUST be obtained through authorized dealers of this product and/or DESA International who will provide original factory replacement parts. Failure to use original factory replacement parts voids this warranty. The heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit.

This warranty does not apply to parts that are not in original condition because of normal wear and tear, or parts that fail or become damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation. Travel, diagnostic cost, labor, transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner.

TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURA- TION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO TWO (2) YEARS FROM THE DATE OF FIRST PURCHASE; AND DESA INTERNATIONAL’S LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND DESA INTERNATIONAL SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT, INCIDENTAL OR CONSEQUEN- TIAL DAMAGES.

Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or consequential damages, so the above limitation on implied warranties, or exclusion or limitation on damages may not apply to you.

This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.

For information about this warranty write:

INTERNATIONAL

2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004 www.desatech.com

103425-01 Rev. D 11/01

NOT A UPC

Model · Date Purchased · 103425 01

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Desa Tech CGG3630P

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.