Desa Tech CBP30T
Table of Contents 80 sections For more information, visit www.desatech.com For more information, visit www.desatech.com · CBN20, CBP20 CBN20T, CBP20T CBN30T, CBP30T · — Do not store or use gasoline or other flammable · TABLE OF CONTENTS · … ShowHide
For more information, visit www.desatech.com For more information, visit www.desatech.comp.1CBN20, CBP20 CBN20T, CBP20T CBN30T, CBP30Tp.1— Do not store or use gasoline or other flammablep.1TABLE OF CONTENTSp.2SAFETY INFORMATION ............................................................ 2p.2SERVICE HINTS....................................................................... 16p.2LOCAL CODES........................................................................... 3p.2TECHNICAL SERVICE ............................................................. 16p.2PRODUCT IDENTIFICATION ..................................................... 3p.2SERVICE PUBLICATIONS ....................................................... 16p.2TROUBLESHOOTING .............................................................. 17p.2PRODUCT FEATURES .............................................................. 3p.2ILLUSTRATED PARTS BREAKDOWN AND PARTS LIST ....... 20p.2AIR FOR COMBUSTION AND VENTILATION ........................... 4p.2REPLACEMENT PARTS .......................................................... 24p.2INSTALLATION ........................................................................... 7p.2ACCESSORIES ........................................................................ 24p.2OPERATING HEATER .............................................................. 13p.2OWNER’S REGISTRATION FORM .......................................... 25p.2INSPECTING HEATER ............................................................. 14p.2PARTS CENTRALS .................................................................. 27p.2CLEANING AND MAINTENANCE ............................................ 15p.2WARRANTY INFORMATION................................. BACK COVERp.2SPECIFICATIONS .................................................................... 16p.2SAFETY INFORMATIONp.2SAFETY INFORMATION PRODUCT IDENTIFICATIONp.3UNPACKINGp.3PRODUCT FEATURESp.3SAFETY DEVICEp.3LOCAL CODESp.3PIEZO IGNITION SYSTEMp.3THERMOSTATIC HEAT CONTROLp.3AIR FOR COMBUSTION AND VENTILATIONp.4Confined and Unconfined Spacep.4PROVIDING ADEQUATE VENTILATIONp.4Unusually Tight Constructionp.4AIR FOR COMBUSTION AND VENTILATION Continuedp.5DETERMINING FRESH-AIR FLOW FOR HEATER LOCATIONp.5Determining if You Have a Confined or Unconfined Spacep.5VENTILATION AIRp.6Ventilation Air From Inside Buildingp.6Ventilation Air From Outdoorsp.6INSTALLATIONp.7CHECK GAS TYPEp.7INSTALLATION ITEMSp.7CEILINGp.7FLOORp.7LOCATING HEATERp.7INSTALLATION Continuedp.8THERMOSTAT SENSING BULBp.8Methods For Attaching Mounting Bracket To Wallp.8INSTALLING HEATER TO WALLp.8Mounting Bracketp.8Attaching Mounting Bracket To Wallp.9MOUNTING HEATER TO FLOORp.10CONNECTING TO GAS SUPPLYp.11CHECKING GAS CONNECTIONSp.12Pressure Testing Gas Supply Piping Systemp.1213 13 OPERATING HEATER For Your Safety Read Before Lightingp.13OPERATING HEATERp.13LIGHTING INSTRUCTIONSp.13LOp.13PILOTp.13OFFp.13HIp.13IGNITORp.13OPERATING HEATER Continuedp.14INSPECTING HEATERp.14PILOT FLAME PATTERNp.14TO TURN OFF GASp.14TO APPLIANCEp.14Shutting Off Burner Only (pilot stays lit)p.14THERMOSTAT CONTROLp.14OPERATIONp.14MANUAL LIGHTINGp.14PROCEDUREp.14INSPECTING HEATER Continuedp.15BURNER FLAME PATTERNp.15CLEANING BURNER PILOT AIR INLETp.151/2 Gp.15
Page 1 of the Desa Tech CBP30T user manual — — Do not store or use gasoline or other flammable
Page 1 · click to enlarge
Page 1
Desa Tech CBP30T — For more information, visit www.desatech.com For more information, visit www.desatech.com diagram (page 1)
Fig. 1 · For more information, visit www.desatech.com For mor…

For more information, visit www.desatech.com For more information, visit www.desatech.com

Desa Tech CBP30T — For more information, visit www.desatech.com For more information, visit www.desatech.com diagram (page 1)
Fig. 2 · For more information, visit www.desatech.com For mor…

CBN20, CBP20 CBN20T, CBP20T CBN30T, CBP30T

— Do not store or use gasoline or other flammable

vapors and liquids in the vicinity of this or any other appliance. — WHAT TO DO IF YOU SMELL GAS

  • Do not try to light any appliance.
  • Do not touch any electrical switch; do not use any phone in your building.
  • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
  • If you cannot reach your gas supplier, call the fire department. — Installation and service must be performed by a

qualified installer, service agency, or the gas supplier.

This appliance may be installed in an aftermarket*, permanently located, manufactured (mobile) home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

*AftermarketCompletion of sale, not for purpose of resale, from the manufacturer

Save this manual for future reference. Save this manual for future reference.

Page 2 of the Desa Tech CBP30T user manual — Table of Contents
Page 2 · Contents
Contents

Contents

For more information, visit www.desatech.com For more information, visit www.desatech.comp.1CBN20, CBP20 CBN20T, CBP20T CBN30T, CBP30Tp.1— Do not store or use gasoline or other flammablep.1TABLE OF CONTENTSp.2SAFETY INFORMATION ............................................................ 2p.2SERVICE HINTS....................................................................... 16p.2LOCAL CODES........................................................................... 3p.2TECHNICAL SERVICE ............................................................. 16p.2PRODUCT IDENTIFICATION ..................................................... 3p.2SERVICE PUBLICATIONS ....................................................... 16p.2TROUBLESHOOTING .............................................................. 17p.2PRODUCT FEATURES .............................................................. 3p.2ILLUSTRATED PARTS BREAKDOWN AND PARTS LIST ....... 20p.2AIR FOR COMBUSTION AND VENTILATION ........................... 4p.2REPLACEMENT PARTS .......................................................... 24p.2INSTALLATION ........................................................................... 7p.2ACCESSORIES ........................................................................ 24p.2OPERATING HEATER .............................................................. 13p.2OWNER’S REGISTRATION FORM .......................................... 25p.2INSPECTING HEATER ............................................................. 14p.2PARTS CENTRALS .................................................................. 27p.2CLEANING AND MAINTENANCE ............................................ 15p.2WARRANTY INFORMATION................................. BACK COVERp.2SPECIFICATIONS .................................................................... 16p.2SAFETY INFORMATIONp.2SAFETY INFORMATION PRODUCT IDENTIFICATIONp.3UNPACKINGp.3PRODUCT FEATURESp.3SAFETY DEVICEp.3LOCAL CODESp.3PIEZO IGNITION SYSTEMp.3THERMOSTATIC HEAT CONTROLp.3AIR FOR COMBUSTION AND VENTILATIONp.4Confined and Unconfined Spacep.4PROVIDING ADEQUATE VENTILATIONp.4Unusually Tight Constructionp.4AIR FOR COMBUSTION AND VENTILATION Continuedp.5DETERMINING FRESH-AIR FLOW FOR HEATER LOCATIONp.5Determining if You Have a Confined or Unconfined Spacep.5VENTILATION AIRp.6Ventilation Air From Inside Buildingp.6Ventilation Air From Outdoorsp.6INSTALLATIONp.7CHECK GAS TYPEp.7INSTALLATION ITEMSp.7CEILINGp.7FLOORp.7LOCATING HEATERp.7INSTALLATION Continuedp.8THERMOSTAT SENSING BULBp.8Methods For Attaching Mounting Bracket To Wallp.8INSTALLING HEATER TO WALLp.8Mounting Bracketp.8Attaching Mounting Bracket To Wallp.9MOUNTING HEATER TO FLOORp.10CONNECTING TO GAS SUPPLYp.11CHECKING GAS CONNECTIONSp.12Pressure Testing Gas Supply Piping Systemp.1213 13 OPERATING HEATER For Your Safety Read Before Lightingp.13OPERATING HEATERp.13LIGHTING INSTRUCTIONSp.13LOp.13PILOTp.13OFFp.13HIp.13IGNITORp.13OPERATING HEATER Continuedp.14INSPECTING HEATERp.14PILOT FLAME PATTERNp.14TO TURN OFF GASp.14TO APPLIANCEp.14Shutting Off Burner Only (pilot stays lit)p.14THERMOSTAT CONTROLp.14OPERATIONp.14MANUAL LIGHTINGp.14PROCEDUREp.14INSPECTING HEATER Continuedp.15BURNER FLAME PATTERNp.15CLEANING BURNER PILOT AIR INLETp.151/2 Gp.15
Page 3 of the Desa Tech CBP30T user manual — THERMOSTATIC HEAT CONTROL
Page 3 · click to enlarge
Page 3
Desa Tech CBP30T — SAFETY INFORMATION PRODUCT IDENTIFICATION diagram (page 3)
Fig. 3

SAFETY INFORMATION PRODUCT IDENTIFICATION

  • 3. If you smell gas
  • shut off gas supply
  • do not try to light any appliance
  • do not touch any electrical switch; do not use any phone in your building
  • immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions
  • if you cannot reach your gas supplier, call the fire department 4. This heater shall not be installed in a bedroom or bathroom. 5. This heater needs fresh, outside air ventilation to run properly. This heater has an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS shuts down the heater if not enough fresh air is available. See Air for Combustion and Ventilation, pages 4 through 6. 6. Keep all air openings in front and bottom of heater clear and free of debris. This will insure enough air for proper combustion. 7. If heater shuts off, do not relight until you provide fresh, outside air. If heater keeps shutting off, have it serviced. 8. Do not run heater
  • where flammable liquids or vapors are used or stored
  • under dusty conditions 9. Do not use heater if any part has been under water. Immediately call a qualified service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water. 10. Turn off and let cool before servicing. Only a qualified service person should service and repair heater. 11. Operating heater above elevations of 4,500 feet could cause pilot outage. 12. To prevent performance problems, do not use propane/LP fuel tank of less than 100 lbs. capacity. 13. Provide adequate clearances around air openings.

Control Knob & Ignitor Button (not seen from this view)

Desa Tech CBP30T — SAFETY INFORMATION PRODUCT IDENTIFICATION diagram (page 3)
Fig. 4

Figure 1 - Vent-Free Gas Heater

UNPACKING

1. Remove heater from carton. 2. Remove all protective packaging applied to heater for shipment. 3. Check heater for any shipping damage. If heater is damaged, promptly return to dealer where you bought heater.

PRODUCT FEATURES

SAFETY DEVICE

LOCAL CODES

This heater has a pilot with an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS/pilot is a required feature for vent- free room heaters. The ODS/pilot shuts off the heater if there is not enough fresh air.

Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of National Fuel Gas Code, ANSI Z223.1/NFPA 54*.

*Available from:

PIEZO IGNITION SYSTEM

American National Standards Institute, Inc.

This heater has a piezo ignitor. This system requires no matches, batteries, or other sources to light heater.

1430 Broadway New York, NY 10018

THERMOSTATIC HEAT CONTROL

National Fire Protection Association, Inc.

Batterymarch Park Quincy, MA 02269

Thermostat models have a thermostat sensing bulb and a control valve. This results in the greatest heater comfort. This can also result in lower gas bills.

107882-01E For more information, visit www.desatech.com For more information, visit www.desatech.com

Grill Guard · Glass Panel

Page 4 of the Desa Tech CBP30T user manual — Unusually Tight Construction
Page 4 · click to enlarge
Page 4
Desa Tech CBP30T — AIR FOR COMBUSTION AND VENTILATION diagram (page 4)
Fig. 5

AIR FOR COMBUSTION AND VENTILATION

Unusually tight construction is defined as construction where: a. walls and ceilings exposed to the outside atmosphere have a continuous water vapor retarder with a rating of one perm (6x10-11 kg per pa-sec-m2) or less with openings gasketed or sealed and b. weather stripping has been added on openable win- dows and doors and c. caulking or sealants are applied to areas such as joints around window and door frames, between sole plates and floors, between wall-ceiling joints, between wall panels, at penetrations for plumbing, electrical, and gas lines, and at other openings.

Desa Tech CBP30T — AIR FOR COMBUSTION AND VENTILATION diagram (page 4)
Fig. 6

Today’s homes are built more energy efficient than ever. New materials, increased insulation, and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in. During heating months, home owners want their homes as airtight as possible.

While it is good to make your home energy efficient, your home needs to breathe. Fresh air must enter your home. All fuel-burning appliances need fresh air for proper combustion and ventilation.

If your home meets all of the three criteria above, you must provide additional fresh air. See Ventilation Air From Outdoors, page 6.

If your home does not meet all of the three criteria above, proceed to Determining Fresh-Air Flow For Heater Loca- tion, page 5.

Exhaust fans, fireplaces, clothes dryers, and fuel burning appliances draw air from the house to operate. You must provide adequate fresh air for these appliances. This will insure proper venting of vented fuel-burning appliances.

Confined and Unconfined Space

PROVIDING ADEQUATE VENTILATION

The National Fuel Gas Code, ANSI Z223.1/NFPA 54 defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space. Rooms communicating directly with the space in which the appliances are installed*, through openings not furnished with doors, are considered a part of the unconfined space.

The following are excerpts from National Fuel Gas Code, ANSI Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation.

All spaces in homes fall into one of the three following ventilation classifications: 1. Unusually Tight Construction 2. Unconfined Space 3. Confined Space

* Adjoining rooms are communicating only if there are doorless passageways or ventilation grills between them.

The information on pages 4 through 6 will help you classify your space and provide adequate ventilation.

Unusually Tight Construction

The air that leaks around doors and windows may provide enough fresh air for combustion and ventilation. However, in buildings of unusually tight construction, you must provide additional fresh air.

107882-01E For more information, visit www.desatech.com For more information, visit www.desatech.com

Page 5 of the Desa Tech CBP30T user manual — Determining if You Have a Confined or Unconfined Space
Page 5 · click to enlarge
Page 5
Desa Tech CBP30T — AIR FOR COMBUSTION AND VENTILATION Continued diagram (page 5)
Fig. 7 · AIR FOR COMBUSTION AND VENTILATION Continued

AIR FOR COMBUSTION AND VENTILATION Determining Fresh-Air Flow For Heater Location

AIR FOR COMBUSTION AND VENTILATION Continued

DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION

4. Compare the maximum Btu/Hr the space can support with the actual amount of Btu/Hr used.

Btu/Hr (maximum the space can support)

Determining if You Have a Confined or Unconfined Space

Btu/Hr (actual amount of Btu/Hr used)

Example51,200 Btu/Hr (maximum the space can support)

Use this work sheet to determine if you have a confined or unconfined space.

60,000 Btu/Hr (actual amount of Btu/Hr used)

Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms.

The space in the above example is a confined space because the actual Btu/Hr used is more than the maximum Btu/Hr the space can support. You must provide additional fresh air. Your options are as follows:

1. Determine the volume of the space (length x width x height).

Length x Width x Height = cu. ft. (volume of space)

A. Rework worksheet, adding the space of an adjoining room. If the extra space provides an unconfined space, remove door to adjoining room or add ventilation grills between rooms. See Ventilation Air From Inside Building, page 6.

Example: Space size 20 ft. (length) x 16 ft. (width) x 8 ft. (ceiling height) = 2560 cu. ft. (volume of space)

If additional ventilation to adjoining room is supplied with grills or open- ings, add the volume of these rooms to the total volume of the space.

B. Vent room directly to the outdoors. See Ventilation Air From Out- doors, page 6.

2. Multiply the space volume by 20 to determine the maximum Btu/Hr the space can support.

C. Install a lower Btu/Hr heater, if lower Btu/Hr size makes room unconfined.

(volume of space) x 20 = (Maximum Btu/Hr the space

If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support, the space is an unconfined space. You will need no additional fresh air ventilation.

Example: 2560 cu. ft. (volume of space) x 20 = 51,200 (maximum Btu/Hr the space can support)

Desa Tech CBP30T — Determining if You Have a Confined or Unconfined Space diagram (page 5)
Fig. 8 · Determining if You Have a Confined or Unconfined Spa…
3. Add the Btu/Hr of all fuel burning appliances in the space.

Vent-free heater Btu/Hr Gas water heater* Btu/Hr Gas furnace Btu/Hr Vented gas heater Btu/Hr Gas fireplace logs Btu/Hr Other gas appliances* + Btu/Hr Total = Btu/Hr

* Do not include direct-vent gas appliances. Direct-vent draws com- bustion air from the outdoors and vents to the outdoors.

ExampleGas water heater _____________ Btu/Hr Vent-free heater + _____________ Btu/Hr Total = _____________ Btu/Hr

107882-01E For more information, visit www.desatech.com For more information, visit www.desatech.com

can support) · 40,000 20,000 60,000

Page 6 of the Desa Tech CBP30T user manual — Ventilation Air From Outdoors
Page 6 · click to enlarge
Page 6

AIR FOR COMBUSTION AND VENTILATION

AIR FOR COMBUSTION AND VENTILATION Continued

VENTILATION AIR

Ventilation Air From Inside Building

Ventilation Grills Into Adjoining Room,

This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 2). You can also remove door into adjoining room (see option 3, Figure 2). Follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.

Or Remove Door into Adjoining

Ventilation Air From Outdoors

Provide extra fresh air by using ventilation grills or ducts. You must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces. Follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.

Figure 2 - Ventilation Air from Inside Building

Desa Tech CBP30T — Ventilation Air From Outdoors diagram (page 6)
Fig. 9 · Ventilation Air From Outdoors

Figure 3 - Ventilation Air from Outdoors

107882-01E For more information, visit www.desatech.com For more information, visit www.desatech.com

Show 9 more labels / short text on this page
Ventilation Air · 12" · Ventilation · Option 2 · Grills into Adjoining · Room, Option 1 · Room, Option 3 · 12" · Outlet Air
Page 7 of the Desa Tech CBP30T user manual — LOCATING HEATER
Page 7 · click to enlarge
Page 7
Desa Tech CBP30T — INSTALLATION diagram (page 7)
Fig. 10

INSTALLATION

Desa Tech CBP30T — INSTALLATION diagram (page 7)
Fig. 11

NOTICE: This heater is intended for use as supple- mental heat. Use this heater along with your primary heating system. Do not install this heater as your primary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circulate the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source.

  • WARNING: Never install the heater
  • in a bedroom or bathroom
  • in a recreational vehicle
  • where curtains, furniture, clothing, or other flammable objects are less than 36 inches from the front, top, or sides of the heater
  • as a fireplace insert
  • in high traffic areas
  • in windy or drafty areas

CHECK GAS TYPE

Use only the correct type of gas (natural or propane/LP). If your gas supply is not the correct gas type, do not install heater. Call dealer where you bought heater for proper type heater.

INSTALLATION ITEMS

CEILING

  • Before installing heater, make sure you have the items listed below.
  • for propane/LP gas, external regulator (supplied by installer)
  • piping (check local codes)
  • sealant (resistant to propane/LP gas)
  • equipment shutoff valve *
  • ground joint union
  • sediment trap
  • tee joint
  • pipe wrench
  • for natural gas, test gauge connection*

Minimum From Sides Of Heater

Minimum To Top Surface Of Carpeting, Tile Or Other Combustible Material

FLOOR

* A CSA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. The optional CSA design-certified equipment shutoff valve can be purchased from your dealer. See Accessories, page 24.

Figure 4 - Mounting Clearances As Viewed From Front of Heater

LOCATING HEATER

  • CAUTION: If you install the heater in a home garage
  • heater pilot and burner must be at least 18 inches above floor
  • locate heater where moving vehicle will not hit it

You can locate heater on the floor, away from a wall. A wall mounting bracket and floor base stand are included with this heater. Determine which method is best for your application.

  • For convenience and efficiency, install heater
  • where there is easy access for operation, inspection, and service
  • in coldest part of room

An optional fan kit is available from your dealer. See Accessories, page 24. If planning to use fan, locate heater near an electrical outlet.

107882-01E For more information, visit www.desatech.com For more information, visit www.desatech.com

Show 6 more labels / short text on this page
36" · 6" · Minimum · Left Side · Right Side · 2"
Page 8 of the Desa Tech CBP30T user manual — INSTALLING HEATER TO WALL
Page 8 · click to enlarge
Page 8
Desa Tech CBP30T — INSTALLATION Continued diagram (page 8)
Fig. 12 · INSTALLATION Continued

INSTALLATION Continued

THERMOSTAT SENSING BULB

Removing Front Panel Of Heater 1. Remove the four painted screws, two on each side of front panel. 2. Pull bottom of front panel forward, then out. 3. Remove any remaining packaging materials.

The thermostat sensing bulb has been placed inside the heater for protection during shipping.

Locating Thermostat Sensing Bulb (for thermostat applications) 1. Remove front panel of heater (see Figure 7). 2. Locate thermostat sensing bulb just under burner assembly.

Desa Tech CBP30T — THERMOSTAT SENSING BULB diagram (page 8)
Fig. 13

Attaching Thermostat Sensing Bulb 1. Remove thermostat sensing bulb from holders inside heater. Route through slot opening in bottom of heater. 2. Place clamp on thermostat sensing bulb as shown in Figure 5. Clamp is provided in hardware package. 3. Snap clamp into upper mounting hole as shown in Figure 5. Mounting hole is located on lower left edge on back of heater. Make sure the thermostat sensing bulb is pointing up.

Desa Tech CBP30T — THERMOSTAT SENSING BULB diagram (page 8)
Fig. 14

Figure 7 - Removing Front Panel Of Heater

Methods For Attaching Mounting Bracket To Wall

Only use last hole on each end of mounting bracket to attach bracket to wall. These two holes are 14 inches apart from their centers. Attach mounting bracket to wall in one of two ways: 1. Attaching to wall stud 2. Attaching to wall anchor

Attaching to Wall Stud: This method provides the strongest hold. Insert mounting screws through mounting bracket and into wall studs.

Figure 5 - Attaching Thermostat Sensing Bulb

Attaching to Wall Anchor: This method allows you to attach mounting bracket to hollow walls (wall areas between studs) or to solid walls (concrete or masonry).

INSTALLING HEATER TO WALL

Mounting Bracket

Decide which method better suits your needs. Either method will provide a secure hold for the mounting bracket.

Locate mounting bracket in heater carton. Remove mounting bracket from heater carton.

Marking Screw Locations 1. Tape mounting bracket to wall where heater will be located. Make sure mounting bracket is level.

Figure 6 - Mounting Bracket

107882-01E For more information, visit www.desatech.com For more information, visit www.desatech.com

Thermostat Sensing Bulb · Clamp

Page 9 of the Desa Tech CBP30T user manual — Attaching Mounting Bracket To Wall
Page 9 · click to enlarge
Page 9
Desa Tech CBP30T — Attaching Mounting Bracket To Wall diagram (page 9)
Fig. 15 · Attaching Mounting Bracket To Wall

INSTALLATION Continued

2. Mark screw locations on wall (see Figure 8). Note: Only mark last hole on each end of mounting bracket. Insert mounting screws through these holes only. 3. Remove tape and mounting bracket from wall.

Attaching To Wall Anchor Method

For attaching mounting bracket to hollow walls (wall areas between studs) or solid walls (concrete or masonry) 1. Drill holes at marked locations using 5/16" drill bit. For solid walls (concrete or masonry), drill at least 1" deep. 2. Fold wall anchor as shown in Figure 9. 3. Insert wall anchor (wings first) into hole. Tap anchor flush to wall. 4. For thin walls (1/2" or less), insert red key into wall anchor. Push red key to “pop” open anchor wings. IMPORTANT: Do not hammer key! For thick walls (over 1/2" thick) or solid walls, do not pop open wings. 5. Place mounting bracket onto wall. Line up last hole on each end of bracket with wall anchors. 6. Insert mounting screws through bracket and into wall anchors. 7. Tighten screws until mounting bracket is firmly fastened to wall.

Desa Tech CBP30T — INSTALLATION Continued diagram (page 9)
Fig. 16 · INSTALLATION Continued
Desa Tech CBP30T — INSTALLATION Continued diagram (page 9)
Fig. 17 · INSTALLATION Continued

Placing Heater On Mounting Bracket 1. Locate two horizontal slots on back panel of heater. 2. Place heater onto mounting bracket. Slide horizontal slots onto stand-out tabs on mounting bracket.

Figure 9 - Folding Anchor Figure 10 - Popping Open Anchor Wings For Thin Walls

Figure 8 - Mounting Bracket Clearances

Attaching Mounting Bracket To Wall

Desa Tech CBP30T — Attaching Mounting Bracket To Wall diagram (page 9)
Fig. 18 · Attaching Mounting Bracket To Wall

Attaching To Wall Stud Method

Mounting Bracket (attached to wall)

For attaching mounting bracket to wall studs 1. Drill holes at marked locations using 9/64" drill bit. 2. Place mounting bracket onto wall. Line up last hole on each end of bracket with holes drilled in wall. 3. Insert mounting screws through bracket and into wall studs. 4. Tighten screws until mounting bracket is firmly fastened to wall studs.

107882-01E For more information, visit www.desatech.com For more information, visit www.desatech.com

Show 4 more labels / short text on this page
30,000 Btu/hr Models · 20,000 Btu/hr Models · Horizontal Slots · Stand-Out Tab
Page 10 of the Desa Tech CBP30T user manual — MOUNTING HEATER TO FLOOR
Page 10 · click to enlarge
Page 10
Desa Tech CBP30T — MOUNTING HEATER TO FLOOR diagram (page 10)
Fig. 19

Installing Heater To Wall (Cont.) Mounting Heater To Floor

INSTALLATION Continued

Installing Bottom Mounting Screws 1. Locate two bottom mounting holes. These holes are near bot- tom on back panel of heater (see Figure 12). 2. Mark screw locations on wall. 3. Remove heater from mounting bracket. 4. If installing bottom mounting screws into hollow or solid wall, install wall anchors. Follow steps 1 through 4 under Attaching To Wall Anchor Method, page 9. If installing bottom mounting screw into wall stud, drill holes at marked locations using 9/64" drill bit. 5. Replace heater onto mounting bracket. 6. Place spacers between bottom mounting holes and wall anchor or drilled hole. 7. Hold spacer in place with one hand. With other hand, insert mounting screw through bottom mounting hole and spacer. Place tip of screw in opening of wall anchor or drilled hole. 8. Tighten both screws until heater is firmly secured to wall. Do not over tighten. Note: Do not replace front panel at this time. Replace front panel after making gas connections and checking for leaks (see pages 11 and 12).

MOUNTING HEATER TO FLOOR

Mounting Base Feet to Heater 1. Lay heater cabinet on its back on a table with the heater bot- tom overhanging the table edge. 2. Align holes in base foot with mounting holes on bottom of cabinet (see Figure 13). 3. Secure base foot to heater using sheet metal screws. 4. Repeat for other side.

Mounting Base Feet to Floor (Where required by local code) 1. Remove front cover (see Removing Front Panel of Heater, page 8). 2. Position heater with base feet in desired location. Mark holes for drilling. Remove heater with base. 3. For carpeted floors, make a small cut with a sharp knife at marked locations prior to drilling. If mounting base to a wood floor, drill 1/8 inch diameter hole, 3/4 inch deep. (Do not use anchors in wood floors). If mounting base to a concrete floor, drill with 1/4 inch diam- eter concrete drill bit, 13/8 inches into floor. Insert anchors com- pletely into holes. 4. Reposition heater with base feet over holes. Secure base to floor with wood screws. See Figure 13.

Figure 12 - Installing Bottom Mounting Screws

Figure 13 - Installing Base Feet

107882-01E For more information, visit www.desatech.com For more information, visit www.desatech.com

Show 8 more labels / short text on this page
Wood Screw · Front View · Heater · Wall · Spacer · Base Foot · Side View · Sheet Metal Screw
Page 11 of the Desa Tech CBP30T user manual — CONNECTING TO GAS SUPPLY
Page 11 · click to enlarge
Page 11
Desa Tech CBP30T — CONNECTING TO GAS SUPPLY diagram (page 11)
Fig. 20

INSTALLATION Continued

CONNECTING TO GAS SUPPLY

Typical Inlet Pipe Diameters

20,000 Btu/Hr Models - 3/8" or greater

Desa Tech CBP30T — CONNECTING TO GAS SUPPLY diagram (page 11)
Fig. 21

30,000 Btu/Hr Models - 1/2" or greater

Installation must include equipment shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 15).

Apply pipe joint sealant lightly to male NPT threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves.

Install sediment trap in supply line as shown in Figure 15. Locate sediment trap where it is within reach for cleaning. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into heater controls. If sediment trap is not installed or is installed wrong, heater may not run properly.

Desa Tech CBP30T — CONNECTING TO GAS SUPPLY diagram (page 11)
Fig. 22

For propane/LP gas, the installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incoming gas pressure, heater regulator damage could occur. Install the external regulator with the vent pointing down as shown in Figure 14. Pointing the vent down protects it from freezing rain or sleet.

Desa Tech CBP30T — CONNECTING TO GAS SUPPLY diagram (page 11)
Fig. 23
Desa Tech CBP30T — CONNECTING TO GAS SUPPLY diagram (page 11)
Fig. 24

Natural Gas From Gas Meter (5" W.C. to 10.5" W.C. Pressure)

Figure 14 - External Regulator With Vent Pointing Down

Propane/LP From External Regulator (11" W.C. to 14" W.C. Pressure)

Figure 15 - Gas Connection

* A CSA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional CSA design-certified equipment shutoff valve from your dealer. See Accessories, page 24.

107882-01E For more information, visit www.desatech.com For more information, visit www.desatech.com

Test Gauge Connection* · Sediment Trap

Page 12 of the Desa Tech CBP30T user manual — Pressure Testing Gas Supply Piping System
Page 12 · click to enlarge
Page 12
Desa Tech CBP30T — CHECKING GAS CONNECTIONS diagram (page 12)
Fig. 25

INSTALLATION Continued

CHECKING GAS CONNECTIONS

Pressure Testing Heater Gas Connections 1. Open equipment shutoff valve (see Figure 16). 2. For natural gas open main gas valve located on or near gas meter. For propane/LP gas open propane/LP supply tank valve. 3. Make sure control knob of heater is in the OFF position. 4. Check all joints from equipment shutoff valve to thermostat gas valve (see Figure 17 or 18). Apply a noncorrosive leak detection fluid to all joints. Bubbles forming show a leak. 5. Correct all leaks at once. 6. Light heater (see Operating Heater, page 13). Check all other internal joints for leaks. 7. Turn off heater (see To Turn Off Gas to Appliance, page 14). 8. Replace front panel.

Desa Tech CBP30T — CHECKING GAS CONNECTIONS diagram (page 12)
Fig. 26
Desa Tech CBP30T — CHECKING GAS CONNECTIONS diagram (page 12)
Fig. 27

Pressure Testing Gas Supply Piping System

Test Pressures In Excess Of 1/2 PSIG (3.5 kPa) 1. Disconnect appliance with its appliance main gas valve (con- trol valve) and equipment shutoff valve from gas supply pip- ing system. Pressures in excess of 1/2 psig will damage heater regulator. 2. Cap off open end of gas pipe where equipment shutoff valve was connected. 3. Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas or opening main gas valve located on or near gas meter for natural gas, or using com- pressed air. 4. Check all joints of gas supply piping system. Apply a noncorrosive leak detection fluid to all joints. Bubbles forming show a leak. 5. Correct all leaks at once. 6. Reconnect heater and equipment shutoff valve to gas supply. Check reconnected fittings for leaks.

Figure 17 - Checking Gas Joints for Natural Gas

Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa) 1. Close equipment shutoff valve (see Figure 16). 2. Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas or opening main gas valve located on or near gas meter for natural gas, or using com- pressed air. 3. Check all joints from gas meter for natural gas (see Figure 17) or propane/LP supply tank for propane/LP gas, to equipment shutoff valve (see Figure 18). Apply a noncorrosive leak de- tection fluid to all joints. Bubbles forming show a leak. 4. Correct all leaks at once.

Desa Tech CBP30T — Pressure Testing Gas Supply Piping System diagram (page 12)
Fig. 28 · Pressure Testing Gas Supply Piping System

Figure 18 - Checking Gas Joints for Propane/LP Gas

107882-01E For more information, visit www.desatech.com For more information, visit www.desatech.com

Show 4 more labels / short text on this page
Thermostat Gas Valve · Equipment Shutoff Valve · Thermostat Gas Valve · Equipment Shutoff Valve
Page 13 of the Desa Tech CBP30T user manual — LIGHTING INSTRUCTIONS
Page 13 · click to enlarge
Page 13
Desa Tech CBP30T — 13 13 OPERATING HEATER For Your Safety Read Before Lighting diagram (page 13)
Fig. 29 · 13 13 OPERATING HEATER For Your Safety Read Before L…

13 13 OPERATING HEATER For Your Safety Read Before Lighting

OPERATING HEATER

  • Note: You may be running this heater for the first time after hooking up to gas supply. If so, the control knob may need to be pressed in for 30 seconds or more. This will allow air to bleed from the gas system.
  • If control knob does not pop up when released, contact a qualified service person or gas supplier for repairs. 6. With control knob pressed in, push down and release ignitor button. This will light pilot. The pilot is attached to the front of burner. The pilot can be seen through the glass panel. If needed, keep pressing ignitor button until pilot lights. Note: If pilot does not stay lit, refer to Troubleshooting , pages 17 through 19. Also contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure, page 14. 7. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.
  • If control knob does not pop up when released, contact a qualified service person or gas supplier for repairs. Note: If pilot goes out, repeat steps 3 through 7. This heater has a safety interlock system. Wait one (1) minute before lighting pilot again. 8. Turn control knob counterclockwise to desired heating level. The main burner should light. Set control knob to any heat level between HI and LO.
Desa Tech CBP30T — 13 13 OPERATING HEATER For Your Safety Read Before Lighting diagram (page 13)
Fig. 30 · 13 13 OPERATING HEATER For Your Safety Read Before L…
  • A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. WHAT TO DO IF YOU SMELL GAS
  • Do not try to light any appliance.
  • Do not touch any electric switch; do not use any phone in your building.
  • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
  • If you cannot reach your gas supplier, call the fire department. C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician or gas supplier. Force or attempted repair may result in a fire or explosion. D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

Ignitor Button Control Knob

LIGHTING INSTRUCTIONS

LO

PILOT

OFF

HI

IGNITOR

1. STOP! Read the safety information above. 2. Make sure equipment shutoff valve is fully open. 3. Turn control knob clockwise to the OFF position. 4. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Fol- low “B” in the safety information above. If you don’t smell gas, go to the next step. 5. Turn control knob counterclockwise to the PILOT position. Press in control knob for five (5) seconds (see Fig- ure 19).

Figure 19 - Control Knob In The OFF Position

Desa Tech CBP30T — LIGHTING INSTRUCTIONS diagram (page 13)
Fig. 31

Figure 20 - Pilot (actual pilot may vary)

107882-01E For more information, visit www.desatech.com For more information, visit www.desatech.com

Thermocouple

Page 14 of the Desa Tech CBP30T user manual — MANUAL LIGHTING
Page 14 · click to enlarge
Page 14
Desa Tech CBP30T — OPERATING HEATER Continued diagram (page 14)
Fig. 32 · OPERATING HEATER Continued

To Turn Off Gas To Appliance Thermostat Control Manual Lighting Procedure INSPECTING HEATER

OPERATING HEATER Continued

INSPECTING HEATER

Check pilot flame pattern and burner flame pattern often.

PILOT FLAME PATTERN

TO TURN OFF GAS

TO APPLIANCE

Figure 21 shows a correct pilot flame pattern. Figure 22 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool. When the thermocouple cools, the heater will shut down.

Shutting Off Heater 1. Turn control knob clockwise to the OFF position. 2. Turn off all electric power to the appliance if service is to be performed.

  • If pilot flame pattern is incorrect, as shown in Figure 22
  • turn heater off (see To Turn Off Gas to Appliance )
  • see Troubleshooting , pages 17 through 19

Shutting Off Burner Only (pilot stays lit)

Turn control knob clockwise to the PILOT position.

THERMOSTAT CONTROL

Desa Tech CBP30T — THERMOSTAT CONTROL diagram (page 14)
Fig. 33

OPERATION

The thermostatic control used on these models differs from standard thermostats. Standard thermostats simply turn on and off the burner. The thermostat used on this heater senses the room temperature. The thermostat adjusts the amount of gas flow to the burner. This increases or decreases the burner flame height. At times the room may exceed the set temperature. If so, the burner will shut off. The burner will cycle back on when room temperature drops below the set temperature. The control knob can be set to any heat level between HI and LO. Selecting the HI setting will cause the burner to remain fully on without modulating down in most cases.

MANUAL LIGHTING

PROCEDURE

1. Remove front panel (see Figure 7, page 8). 2. Follow steps 1 through 5 under Lighting Instructions, page 13. 3. With control knob pressed in, strike match. Hold match to pilot until pilot lights. 4. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow step 8, under Lighting Instructions, page 13. 5. Replace front panel.

107882-01E For more information, visit www.desatech.com For more information, visit www.desatech.com

Page 15 of the Desa Tech CBP30T user manual — CABINET
Page 15 · click to enlarge
Page 15
Desa Tech CBP30T — INSPECTING HEATER Continued diagram (page 15)
Fig. 34 · INSPECTING HEATER Continued

INSPECTING HEATER Continued

ODS/PILOT AND BURNER • Use a vacuum cleaner, pressurized air, or small, soft bristled brush to clean.

BURNER FLAME PATTERN

CLEANING BURNER PILOT AIR INLET

Desa Tech CBP30T — BURNER FLAME PATTERN diagram (page 15)
Fig. 35

The primary air inlet holes allow the proper amount of air to mix with the gas. This provides a clean burning flame. Keep these holes clear of dust, dirt, and lint. Clean these air inlet holes prior to each heating season. Blocked air holes will create soot. We recommend that you clean the unit every three months during operation and have heater inspected yearly by a qualified service person.

We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt. To clean these parts we recommend using compressed air no greater than 30 PSI. Your local computer store, hardware store, or home center may carry com- pressed air in a can. You can use a vacuum cleaner in the blow position. If using compressed air in a can, please follow the direc- tions on the can. If you don't follow directions on the can, you could damage the pilot assembly. 1. Shut off the unit, including the pilot. Allow the unit to cool for at least thirty minutes. 2. Inspect burner, pilot for dust and dirt. 3. Blow air through the ports/slots and holes in the burner. 4. Never insert objects into the pilot tube.

Figure 23 shows a correct burner flame pattern. Figure 24 shows an incorrect burner flame pattern. The incorrect burner flame pattern shows yellow tipping of the flame. It also shows the flame higher than 1/2 the glass panel height.

  • If burner flame pattern is incorrect, as shown in Figure 24
  • turn heater off (see To Turn Off Gas To Appliance , page 14)
  • see Troubleshooting , pages 17 through 19

1/2 Glass Height

1/2 G

Clean the pilot assembly also. A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly. There is a small pilot air inlet about two inches from where the pilot flame comes out of the pilot assembly (see Figure 25). With the unit off, lightly blow air through the air inlet. You may blow through a drinking straw if compressed air is not available.

Figure 23 - Correct Burner Flame Pattern

1/2 Glass Height

Desa Tech CBP30T — 1/2 G diagram (page 15)
Fig. 36

1/2 G

Figure 24 - Incorrect Burner Flame Pattern

CLEANING AND MAINTENANCE

Desa Tech CBP30T — CLEANING AND MAINTENANCE diagram (page 15)
Fig. 37

Figure 25 - Pilot Inlet Air (Propane/LP Pilot Shown)

CABINET

  • Air Passageways
  • Use a vacuum cleaner or pressurized air to clean. Exterior
  • Use a soft cloth dampened with a mild soap and water mixture. Wipe the cabinet to remove dust.

107882-01E For more information, visit www.desatech.com For more information, visit www.desatech.com

Blue Flame · Yellow Tipping

Page 16 of the Desa Tech CBP30T user manual — SERVICE HINTS
Page 16 · click to enlarge
Page 16
Desa Tech CBP30T — INSPECTING HEATER Continued diagram (page 16)
Fig. 38 · INSPECTING HEATER Continued

SPECIFICATIONS

CBN20/CBN20T CBN30T

Btu (Variable) 10,000/20,000 15,000/30,000 Type Gas Natural Only Natural Only Ignition Piezo Piezo Pressure Regulator Setting 3" W.C. 3" W.C. Inlet Gas Pressure (in. of water)

Maximum 10.5" 10.5" Minimum 4" 4" Dimensions, Inches (H x W x D)

Heater (Includes knobs & grill) 26.25 x 18.25 x 7 26.25 x 25.75 x 7 Carton 28.25 x 21.25 x 9 28.25 x 29 x 9 Weight (pounds)

Heater 20 28 Shipping 25 33

CBP20/CBP20T CBP30T

Btu (Variable) 10,000/20,000 15,000/30,000 Type Gas Propane/LP Only Propane/LP Only Ignition Piezo Piezo Pressure Regulator Setting 8" W.C. 8" W.C. Inlet Gas Pressure (in. of water)

Maximum 14" 14" Minimum 11" 11" Dimensions, Inches (H x W x D)

Heater (Includes knobs & grill) 26.25 x 18.25 x 7 26.25 x 25.75 x 7 Carton 28.25 x 21.25 x 9 28.25 x 29 x 9 Weight (pounds)

Heater 20 28 Shipping 25 33

SERVICE HINTS

TECHNICAL SERVICE

You may have further questions about installation, operation, or troubleshooting. If so, contact DESA International’s Technical Service Department at 1-866-672-6040. When calling please have your model and serial numbers of your heater ready.

  • When Gas Pressure Is Too Low
  • pilot will not stay lit
  • burner will have delayed ignition
  • heater will not produce specified heat
  • propane/LP gas supply may be low

You can also visit DESA International’s technical service web site at www.desatech.com

You may feel your gas pressure is too low. If so, contact your local natural or propane/LP gas supplier. SERVICE PUBLICATIONS

You can purchase a service manual from the address listed on the back page of this manual. Send a check for $5.00 payable to DESA International.

107882-01E For more information, visit www.desatech.com For more information, visit www.desatech.com

Page 17 of the Desa Tech CBP30T user manual — OBSERVED PROBLEM
Page 17 · click to enlarge
Page 17
Desa Tech CBP30T — INSPECTING HEATER Continued diagram (page 17)
Fig. 39 · INSPECTING HEATER Continued

TROUBLESHOOTING WARNING: Turn off and un- plug heater and let cool before servicing. Only a qualified ser- vice person should service and repair heater.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

When ignitor button is pressed, there is no spark at ODS/pilot

1. Ignitor electrode positioned wrong 2. Ignitor electrode broken 3. Ignitor electrode not connected to ignitor cable 4. Ignitor cable pinched or wet
1. Replace pilot assembly 2. Replace pilot assembly 3. Reconnect ignitor cable
4. Free ignitor cable if pinched by any metal or tubing. Keep ignitor cable dry 5. Replace ignitor cable 6. Replace piezo ignitor
5. Broken ignitor cable 6. Bad piezo ignitor

When ignitor button is pressed, there is spark at ODS/pilot but no ignition

1. Gas supply turned off or equipment shutoff valve closed 2. Control knob not in PILOT position 3. Control knob not pressed in while in PILOT position 4. Air in gas lines when installed
1. Turn on gas supply or open equipment shutoff valve 2. Turn control knob to PILOT position 3. Press in control knob while in PILOT position 4. Continue holding down control knob. Repeat igniting operation until air is removed 5. Contact local propane/LP gas company 6. Clean ODS/pilot (see Cleaning and Maintenance , page 15) or replace ODS/ pilot assembly 7. Replace gas regulator
5. Depleted gas supply (propane/LP gas only) 6. ODS/pilot is clogged
7. Gas regulator setting is not correct

ODS/pilot lights but flame goes out when control knob is released

1. Control knob not fully pressed in 2. Control knob not pressed in long enough
1. Press in control knob fully 2. After ODS/pilot lights, keep control knob pressed in 30 seconds 3. Wait one minute for safety interlock system to reset. Repeat ignition operation 4. Fully open equipment shutoff valve 5. Hand tighten until snug, then tighten 1/4 turn more 6. A) Contact local natural or propane/LP gas company
3. Safety interlock system has been triggered
4. Equipment shutoff valve not fully open 5. Thermocouple connection loose at control valve 6. Pilot flame not touching thermocouple, which allows thermocouple to cool, causing pilot flame to go out. This problem could be caused by one or both of the following: A) Low gas pressure B) Dirty or partially clogged ODS/pilot 7. Thermocouple damaged 8. Control valve damaged

B) Clean ODS/pilot (see Cleaning and Maintenance, page 15) or replace ODS/ pilot assembly

7. Replace pilot assembly 8. Replace control valve

107882-01E For more information, visit www.desatech.com For more information, visit www.desatech.com

Page 18 of the Desa Tech CBP30T user manual — OBSERVED PROBLEM
Page 18 · click to enlarge
Page 18
Desa Tech CBP30T — INSPECTING HEATER Continued diagram (page 18)
Fig. 40 · INSPECTING HEATER Continued

TROUBLESHOOTING Continued

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Burner does not light after ODS/pilot is lit

1. Burner orifice is clogged
1. Clean burner (see Cleaning and Maintenance , page 15) or replace burner orifice 2. Contact local natural or propane/LP gas company
2. Inlet gas pressure is too low

Delayed ignition of burner

1. Manifold pressure is too low
1. Contact local natural or propane/LP gas company 2. Clean burner (see Cleaning and Maintenance , page 15) or replace burner orifice
2. Burner orifice is clogged

Burner backfiring during combustion

1. Burner orifice is clogged or damaged
1. Clean burner (see Cleaning and Maintenance , page 15) or replace burner orifice 2. Replace burner 3. Replace gas regulator
2. Burner damaged 3. Gas regulator defective

Yellow flame during burner combustion

1. Not enough air
1. Check burner for dirt and debris. If found, clean burner (see Cleaning and Maintenance , page 15) 2. Replace gas regulator 3. Clean burner (see Cleaning and Maintenance , page 15)
2. Gas regulator defective 3. Clogged or dirty burner

Slight smoke or odor during initial operation

1. Residues from manufacturing processes
1. Problem will stop after a few hours of operation

Heater produces a whistling noise when burner is lit

1. Turning control knob to HI position when burner is cold 2. Air in gas line
1. Turn control knob to LO position and let warm up for a minute 2. Operate burner until air is removed from line. Have gas line checked by local natural or propane/LP gas company 3. Observe minimum installation clearances (see Figure 4, page 7) 4. Clean burner (see Cleaning and Maintenance , page 15) or replace burner orifice
3. Air passageways on heater blocked
4. Dirty or partially clogged burner orifice

White powder residue forming within burner box or on adjacent walls or furniture

1. When heated, vapors from furniture polish, wax, carpet cleaner, etc., may turn into white powder residue
1. Turn heater off when using furniture polish, wax, carpet cleaners, or similar products

107882-01E For more information, visit www.desatech.com For more information, visit www.desatech.com

Page 19 of the Desa Tech CBP30T user manual — OBSERVED PROBLEM
Page 19 · click to enlarge
Page 19
Desa Tech CBP30T — INSPECTING HEATER Continued diagram (page 19)
Fig. 41 · INSPECTING HEATER Continued

TROUBLESHOOTING Continued

Desa Tech CBP30T — TROUBLESHOOTING Continued diagram (page 19)
Fig. 42 · TROUBLESHOOTING Continued
  • WARNING: If you smell gas
  • Shut off gas supply.
  • Do not try to light any appliance.
  • Do not touch any electrical switch; do not use any phone in your building.
  • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
  • If you cannot reach your gas supplier, call the fire department.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Heater produces a clicking/ticking noise just after burner is lit or shut off

1. Metal expanding while heating or contracting while cooling
1. This is common with most heaters. If noise is excessive, contact qualified service person

Heater produces unwanted odors

1. Heater burning vapors from paint, hair spray, glues, etc. (see IMPORTANT statement above) 2. Low fuel supply (propane/LP gas only) 3. Gas leak. See Warning statement at top of page
1. Ventilate room. Stop using odor causing products while heater is running
2. Refill supply tank 3. Locate and correct all leaks (see Checking Gas Connections , page 12)
Desa Tech CBP30T — OBSERVED PROBLEM diagram (page 19)
Fig. 43
1. Not enough fresh air is available 2. Low line pressure
1. Open window and/or door for ventilation 2. Contact local natural or propane/LP gas company 3. Clean ODS/pilot (see Cleaning and Maintenance , page 15)

Gas odor even when control knob is in OFF position

1. Gas leak. See Warning statement at top of page 2. Control valve defective
1. Locate and correct all leaks (see Checking Gas Connections, page 12) 2. Replace control valve

Gas odor during combustion

1. Foreign matter between control valve and burner 2. Gas leak. See Warning statement at top of page
1. Take apart gas tubing and remove foreign matter 2. Locate and correct all leaks (see Checking Gas Connections , page 12)

Moisture/condensation noticed on windows

1. Not enough combustion/ventilation air
1. Refer to Air for Combustion and Ventilation requirements (page 4)

107882-01E For more information, visit www.desatech.com For more information, visit www.desatech.com

Page 20 of the Desa Tech CBP30T user manual — INSPECTING HEATER Continued
Page 20 · click to enlarge
Page 20
Desa Tech CBP30T — INSPECTING HEATER Continued diagram (page 20)
Fig. 44 · INSPECTING HEATER Continued

107882-01E For more information, visit www.desatech.com For more information, visit www.desatech.com

Page 21 of the Desa Tech CBP30T user manual — PARTS AVAILABLE — NOT SHOWN
Page 21 · click to enlarge
Page 21
Desa Tech CBP30T — INSPECTING HEATER Continued diagram (page 21)
Fig. 45 · INSPECTING HEATER Continued

PARTS LIST

This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 24 of this manual.

KEY PART NUMBER FOR NO. CBN20 CBP20 DESCRIPTION QTY.

1 097159-04 097159-04 Piezo Ignitor 1 2 107954-01 107954-01 Front Panel 1 3 107879-02 107879-02 Grill Guard 1 4 1110038-03 110038-04 Control Valve 1 5 107677-01 107677-01 Glass Retainer 2 6 098260-12 098260-12 Glass 1 7 ** ** Cabinet 1 8 107894-08 107894-08 Deflector Assembly 1 9 098271-09 098271-09 Ignitor Cable 1 10 098249-01 098249-01 Nut, M5 2 11 110803-01 110803-02 ODS/Pilot Assembly 1 110186-01 110186-01 Thermocouple Kit 1 12 103446-01 103446-01 Burner 1 13 099387-05 099387-05 3/16" Pilot Tubing 1 14 103845-06 103845-05 Injector 1 15 099066-02 099066-02 Mounting Bracket 1 16 099415-17 099415-18 Gas Regulator 1 17 Hex Nut 1 18 103570-04 103570-04 3/8" Outlet Tubing 1 19 103572-03 103572-03 3/8" Inlet Tubing 1 20 098508-01 098508-01 Valve Retainer Nut 1 21 098354-02 098354-02 Control Knob 1 22 109303-04 109303-04 Baffle 1

PARTS AVAILABLE — NOT SHOWN

100642-03 100642-03 Hardware Assembly 1 105345-01 105345-01 Cable Tie 1 107888-01 107888-01 Control Position Label 1 109483-01 109483-01 Lighting Instruction Plate 1 GA4550 GA4550 Base Kit 1

** Not a field replaceable part.

107882-01E For more information, visit www.desatech.com For more information, visit www.desatech.com

Page 22 of the Desa Tech CBP30T user manual — INSPECTING HEATER Continued
Page 22 · click to enlarge
Page 22
Desa Tech CBP30T — INSPECTING HEATER Continued diagram (page 22)
Fig. 46 · INSPECTING HEATER Continued
Desa Tech CBP30T — INSPECTING HEATER Continued diagram (page 22)
Fig. 47 · INSPECTING HEATER Continued

107882-01E For more information, visit www.desatech.com For more information, visit www.desatech.com

Page 23 of the Desa Tech CBP30T user manual — PARTS AVAILABLE — NOT SHOWN
Page 23 · click to enlarge
Page 23
Desa Tech CBP30T — INSPECTING HEATER Continued diagram (page 23)
Fig. 48 · INSPECTING HEATER Continued

PARTS LIST

This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 24 of this manual.

KEY PART NUMBER FOR NO. CBN20T CBP20T CBN30T CBP30T DESCRIPTION QTY.

1 097159-04 Piezo Ignitor 1 2 107954-01 107954-01 107955-01 107955-01 Front Panel 1 3 107879-02 107879-02 107879-01 107879-01 Grill Guard 1 4 098522-10 098522-11 098522-12 098522-13 Thermostat Gas Valve 1 5 107677-01 Glass Retainer 2 6 098260-12 098260-12 098260-13 098260-13 Glass 1 7 ** Cabinet 1 8 107894-08 107894-08 107894-09 107894-09 Deflector Assembly 1 9 098271-09 Ignitor Cable 1 10 098249-01 Nut, M5 2 11 110803-01 110803-02 110803-01 110803-02 ODS/Pilot Assembly 1 110186-01 Thermocouple Kit 1 12 103446-01 103446-01 103447-01 103447-01 Burner 1 13 099387-03 3/16" Pilot Tubing 1 14 103845-06 103845-05 103845-08 103845-07 Injector 1 15 099066-02 Mounting Bracket 1 16 099415-17 099415-18 099415-17 099415-18 Gas Regulator 1 17 NJF 8C NJF 8C NJF 8C NJF 8C Hex Nut 1 18 103255-02 3/8" Outlet Tubing 1 19 103256-02 3/8" Inlet Tubing 1 20 109303-04 109303-04 109303-03 109303-03 Baffle 1

PARTS AVAILABLE — NOT SHOWN

100642-03 Hardware Assembly 1 105345-01 Cable Tie 1 107888-01 Control Position Label 1 109483-01 Lighting Instruction Plate 1 GA4550 Base Kit 1

** Not a field replaceable part.

107882-01E For more information, visit www.desatech.com For more information, visit www.desatech.com

Page 24 of the Desa Tech CBP30T user manual — PARTS NOT UNDER WARRANTY
Page 24 · click to enlarge
Page 24
Desa Tech CBP30T — INSPECTING HEATER Continued diagram (page 24)
Fig. 49 · INSPECTING HEATER Continued

REPLACEMENT PARTS

ACCESSORIES

Purchase these heater accessories from your local dealer. If they can not supply these accessories, either contact your nearest Parts Central (see page 27) or call DESA International at 1-866-672-6040 for referral information. You can also write to the address listed on the back page of this manual.

PARTS UNDER WARRANTY

Contact authorized dealers of this product. If they can’t supply original replacement part(s), call DESA International’s Technical Service Department at 1-866-672-6040.

  • When calling DESA International, have ready
  • your name
  • your address
  • model and serial numbers of your heater
  • how heater was malfunctioning
  • type of gas used (propane/LP or natural gas)
  • purchase date

EQUIPMENT SHUTOFF VALVE - GA5010

For all models. Equipment shutoff valve with 1/8" NPT tap.

Usually, we will ask you to return the part to the factory.

PARTS NOT UNDER WARRANTY

Desa Tech CBP30T — PARTS NOT UNDER WARRANTY diagram (page 24)
Fig. 50

Contact authorized dealers of this product. If they can’t supply original replacement part(s), either contact your nearest Parts Cen- tral (see page 27) or call DESA International at 1-866-672-6040 for referral information.

  • When calling DESA International, have ready
  • model number of your heater
  • the replacement part number

FAN KITS - GA3250T For all models. Provides better heat distribution. Makes heater more efficient. Complete installation and operating instructions included. Thermostatically-controlled, blower turns itself on and off as required.

107882-01E For more information, visit www.desatech.com For more information, visit www.desatech.com

Page 25 of the Desa Tech CBP30T user manual — OWNER'S REGISTRATION FORM
Page 25 · click to enlarge
Page 25

OWNER'S REGISTRATION FORM

In order to provide better customer service for this and future purchases, we recommend that you register your product with us. You can register online at www.desatech.com. If access to our website is not available to you, please complete this Owner’s Registration Form and mail to the address on the back of this owner’s manual. Please provide the following product information:

Brand(Comfort Glow, Vanguard, etc.)
Model(EFP33PR, VTGH33NR, etc.)

Date Purchased: Note: Keep receipt for warranty verification.

Serial Number: 7 or 9 digit number located on product or identification tag.

First NameLast Name:

Address:

CityState: Zip: Country:
Home Phone( ) -

E-Mail:

Please answer the following questions to register your product with DESA International:

1. Where will the product be used?

❍ Living/Family Room ❍ Office/Warehouse ❍ Utility Shed/Outbuilding ❍ Garage ❍ Bedroom ❍ Bathroom ❍ Other

2. If you bought this product yourself, did you plan to purchase this type of product before going into the store? ❍ Yes ❍ No
3. Who selected the product? ❍ Male ❍ Female ❍ Both
4. What is the population of your area? ❍ Under 10,000 ❍ 10,000 to 25,000 ❍ 25,000 to 50,000 ❍ 50,000 to 100,000

❍ 100,000 to 250,000 ❍ Over 250,000

5. What is your primary source of heat? ❍ Propane (LP Gas) ❍ Fuel Oil ❍ Wood ❍ Natural Gas ❍ Electric ❍ Other
6. How was the product installed? ❍ Professional Installer ❍ Self ❍ Other
7. Cost of product excluding sales tax? $
8. Cost to install product? $
9. Type of store where product was purchased? ❍ Hardware ❍ Propane Dealer ❍ Natural Gas/Utility Co. ❍ Home Center/Builder’s Supply

❍ Fireplace or Hearth Shop ❍ Farm Store ❍ Other

10. What motivated you to buy this product? ❍ Sudden Cold Weather ❍ Replace Older Model ❍ D.I.Y. Home Project

❍ Emergency Back-Up Heat ❍ Heater was on Sale ❍ Energy Savings/High Efficiency ❍ Construction Project ❍ Other

11. How did you learn about this product brand? ❍ Advertising ❍ Relative or Friend ❍ Store Display ❍ Other
12. Level of Education of Purchaser: ❍ Some High School ❍ Completed High School ❍ Completed College ❍ Completed Graduate School
13. Age of Purchaser: ❍ Under 20 ❍ 20 - 29 ❍ 30 - 39 ❍ 40 - 49 ❍ 50 - 59 ❍ 60 or Over
14. Buyer’s total annual household income: ❍ Under $15,000 ❍ $15,000 to $19,999 ❍ $20,000 to $34,999 ❍ $35,000 to $49,999

❍ $50,000 to $74,999 ❍ $75,000 to $99,999 ❍ $100,000 and Over

15. Store where product was purchased:
Name______________________________________
City_______________________ State: __________
16. In choosing this product, how important were the following:

Not Important Somewhat Important Very Important

Thermostat, Remote, or Manual Operation

107882-01E For more information, visit www.desatech.com For more information, visit www.desatech.com

Show 71 more labels / short text on this page
Availability · ❍ · ❍ · ❍ · Price · ❍ · ❍ · ❍ · Brand Name · ❍ · ❍ · ❍ · Overall Quality · ❍ · ❍ · ❍ · Heat Output · ❍ · ❍ · ❍ · Made in USA · ❍ · ❍ · ❍ · Warranty · ❍ · ❍ · ❍ · Local Service · ❍ · ❍ · ❍ · Value for Price · ❍ · ❍ · ❍ · Prior Brand Experience · ❍ · ❍ · ❍ · Controls Location · ❍ · ❍ · ❍ · ❍ · ❍ · ❍ · Ease of Operation · ❍ · ❍ · ❍ · Special Features · ❍ · ❍ · ❍ · Salesperson’s Recommendation · ❍ · ❍ · ❍ · Friend/Relative’s Recommendation · ❍ · ❍ · ❍ · Portability · ❍ · ❍ · ❍ · Quiet Operation · ❍ · ❍ · ❍
Page 26 of the Desa Tech CBP30T user manual — TM
Page 26 · click to enlarge
Page 26
Desa Tech CBP30T — INSPECTING HEATER Continued diagram (page 26)
Fig. 51 · INSPECTING HEATER Continued

TM

2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004

Desa Tech CBP30T — TM diagram (page 26)
Fig. 52

107882-01E For more information, visit www.desatech.com For more information, visit www.desatech.com

Postage Required

Page 27 of the Desa Tech CBP30T user manual — PARTS CENTRALS
Page 27 · click to enlarge
Page 27
Desa Tech CBP30T — INSPECTING HEATER Continued diagram (page 27)
Fig. 53 · INSPECTING HEATER Continued

PARTS CENTRALS

These Parts Centrals are privately owned businesses. They have agreed to support our customer’s needs by providing original replacement parts and accessories.

Baltimore Electric 5 Manila Ave Hamden, CT 06514-0322 1-800-397-7553 203-248-7553

Master Parts Dist. 1251 Mound Ave. NW Grand Rapids, MI 49504-2672 616-791-0505 1-800-446-1446 www.nbmc.com

Halco Enterprises 208 Carter Drive, Unit 21 West Chester, PA 19382-4500 610-430-7717 1-800-368-0803 www.halcoenterprises.com

Portable Heater Parts 342 N. County Rd. 400 East Valparaiso, IN 46383-9704 219-462-7441 1-888-619-7060 www.portableheaterparts.com sales@portableheaterparts.com techservice@portableheaterparts.com

Washer Equipment Co. 1715 Main Street Kansas City, MO 64108-2195 KS, MO, AR 816-842-3911 www.washerparts.com

Laporte’s Parts & Service 2444 N. 5th Street Hartsville, SC 29550-7704 843-332-0191 Parts Department

Cans Unlimited P.O. Box 645 Taylor, SC 29687-0013 803-879-3009 1-800-845-5301 cuisales@aol.com

East Coast Energy 707 Broadway W. Long Branch, NJ 07764-1542 732-870-8809 1-800-755-8809 www.njplaza.com/ecep

FBD 1349 Adams Street Bowling Green, KY 42103-3414 270-846-1199 1-800-654-8534 Fax: 1-800-846-0090 franktalk@aol.com

Dayton Hardware P.O. Box 275 North Dayton Station Dayton, OH 45404-0275 937-258-3721 OHIO only 1-800-762-3426

107882-01E For more information, visit www.desatech.com For more information, visit www.desatech.com

Page 28 of the Desa Tech CBP30T user manual — NOT A UPC
Page 28 · click to enlarge
Page 28
Desa Tech CBP30T — INSPECTING HEATER Continued diagram (page 28)
Fig. 54 · INSPECTING HEATER Continued

KEEP THIS WARRANTY

Desa Tech CBP30T — KEEP THIS WARRANTY diagram (page 28)
Fig. 55

Always specify model and serial numbers when communicating with the factory.

We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied.

LIMITED WARRANTY VENT-FREE RESIDENTIAL GAS HEATERS

DESA International warrants this product to be free from defects in materials and components for two (2) years from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions. To make a claim under this warranty the Bill of Sale or cancelled check must be presented.

This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required to restore this heater to proper operating condition and an allowance for labor when provided by a DESA Authorized Service Center. Warranty part(s) MUST be obtained through authorized dealers of this product and/or DESA International who will provide original factory replacement parts. Failure to use original factory replacement parts voids this warranty. The heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit.

This warranty does not apply to parts that are not in original condition because of normal wear and tear, or parts that fail or become damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation. Travel, diagnostic cost, labor, transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner.

TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO TWO (2) YEARS ON ALL COMPONENTS FROM THE DATE OF FIRST PURCHASE; AND DESA INTERNATIONAL’S LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND DESA INTERNATIONAL SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES.

Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or consequential damages, so the above limitation on implied warranties, or exclusion or limitation on damages may not apply to you.

This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.

For information about this warranty write:

TM

2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004 www.desatech.com

107882-01 Rev. E 09/02

NOT A UPC

107882-01E For more information, visit www.desatech.com For more information, visit www.desatech.com

107882 01

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Desa Tech CBP30T

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Desa Tech CBP30T

Be the first to ask — other owners or our team will answer.

Original document

Desa Tech CBP30T manual PDF

28 pages·1.7 MB·Gas Heater·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…