Technical Guide

1-socket 1U rack server providing the features you need without a lot of the unnecessary extras.

This document is for informational purposes only. Dell reserves the right to make changes without further notice to any products herein. The content provided is as is and without express or implied warranties of any kind.
Dell, PowerEdge, PowerVault, OpenManage, and ReadyRails are trademarks of Dell, Inc. Citrix® and XenServer™ are trademarks of Citrix Systems, Inc. and/or one or more of its subsidiaries, and may be registered in the United States Patent and Trademark Office and in other countries. ENERGY STAR is a registered trademark of the Environmental Protection Agency (EPA). Intel, Xeon, and Pentium are registered trademarks and Core is a trademark of Intel Corporation in the U.S. and other countries. HP and COMPAQ are trademarks of Hewlett-Packard Company. Broadcom is a registered trademark and NetXtreme is a trademark of Broadcom Corporation and/or its affiliates in the United States, certain other countries and/or the EU. CommVault Galaxy® or Simpana® are registered trademarks of CommVault Systems, Inc. InfiniBand is a registered trademark and service mark of the InfiniBand Trade Association. Matrox is a registered trademark of Matrox Electronic Systems Ltd. Microsoft and SQL Server are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries. Mellanox is a registered trademark of Mellanox Technologies, Inc. and ConnectX, InfiniBlast, InfiniBridge, InfiniHost, InfiniRISC, InfiniScale, and InfiniPCI are trademarks of Mellanox Technologies, Inc. Red Hat is a registered trademark of Red Hat, Inc. in the United States and other countries. Linux is a registered trademark of Linus Torvalds. Symantec and Backup Exec are trademarks owned by Symantec Corporation or its affiliates in the U.S. and other countries. Novell, SUSE, PlateSpin, and PowerConvert are registered trademarks of Novell, Inc. QLogic and PathScale are registered trademarks of Qlogic Corporation. VMware is a registered trademark and vSphere is a trademark of VMware, Inc. in the United States and/or other jurisdictions. Vizioncore, vRanger, vConverter, and vFoglight are trademarks of Vizioncore Inc. in the United States of America and other countries. Winbond is a registered trademark of Winbond Electronics Corporation. Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Dell disclaims proprietary interest in the marks and names of others.
©Copyright 2010 Dell Inc. All rights reserved. Reproduction or translation of any part of this work beyond that permitted by U.S. copyright laws without the written permission of Dell Inc. is unlawful and strictly forbidden.
Initial Release April 2010


5.7 Acoustics 29 6 Processors 31 6.1 Overview 31 6.2 Supported Processors 31 6.3 Processor Configurations 31 7 Memory 32 7.1 Overview 32 7.2 DIMMs Supported 32 7.3 Slots/Risers 33 7.4 Speed 33 7.5 Sparing 33 7.6 Mirroring 33 7.7 RAID 33 8 Chipset 34 8.1 Overview 34 8.2 Direct Media Interface 34 8.3 PCI Express Interface 34 8.4 SATA Interface 34 8.5 AHCI 34 8.6 PCI Interface 34 8.7 Low Pin Count (LPC) Interface 35 8.8 Serial Peripheral Interface (SPI) 35 8.9 Compatibility Module 35 8.10 Advanced Programmable Interrupt Controller (APIC) 35 8.11 USB Interface 35 8.12 Real-Time Clock (RTC) 36 8.13 GPIO 36 8.14 Enhanced Power Management 36 8.15 System Management Features 36 8.15.1 TCO Timer 36 8.15.2 Processor Present Indicator 36 8.15.3 Error Code Correction (ECC) Reporting 36 8.15.4 Function Disable 37 8.16 System Management Bus (SMBus 2.0) 37 8.17 Intel Anti-Theft Technology 37 8.18 Intel Virtualization Technology for Directed I/O 37 8.19 JTAG Boundary-Scan 38 9 BIOS 39 9.1 Overview 39 9.2 ACPI 40 9.3 Power Management Modes 40 9.3.1 Dell Active Power Controller 40 9.3.2 Power Saving BIOS Setting (OS Control) 41 9.3.3 Maximum Performance 41 10 I/O Slots 43 10.1 Overview 43 10.2 PCI Devices 44 10.3 Boot Order 47 10.4 NICs 47

11 Storage 48 11.1 Overview 48 11.2 Drives 48 11.3 RAID Configurations 49 11.4 Optical Disk Drive (ODD) 49 11.5 Tape Drives 50 12 Video and Audio 51 12.1 Video 51 12.2 Audio 51 13 Rack Information 52 13.1 Overview 52 13.2 Rails 52 13.3 Cable Management Arm (CMA) 52 14 Operating Systems 53 15 Virtualization 55 16 Systems Management 56 16.1 Overview 56 16.2 Server Management 56 16.3 Embedded Server Management 57 16.4 Lifecycle Controller and Unified Server Configurator 57 16.5 iDRAC6 Express 58 16.6 iDRAC6 Enterprise 58 17 Peripherals 61 17.1 USB 61 17.2 USB Device 61 17.3 External Storage 62 18 Packaging Options 62
Table 1. Comparison of PowerEdge Server Features 8 Table 2. Comparison Overview PERC S100 and S300 12 Table 3. eSATA Modes 13 Table 4. Product Feature Summary 14 Table 5. Overall Dimensions and Weight 16 Table 6. Specific Measurements 16 Table 7. TPM Pin Signals 23 Table 8. Power Supply 24 Pins and Signals 26 Table 9. Power Supply 4 Pins and Signals 26 Table 10. PSU Specifications 28 Table 11. Acoustical Specifications 29 Table 12. Processor Information 31 Table 13. Supported Processor Configurations 32 Table 14. Wake Up Events and States 40 Table 15. Summary of R210 Power Management Features 41 Table 16. Power Profiles that R210 BIOS will Expose in BIOS Setup 42

Table 17. I/O Slot Information 45 Table 18. PCI Card Dimensions 46 Table 19. Bandwidth, Quantities, and Priorities 46 Table 20. Available Drives 48 Table 21. RAID Configurations 49 Table 22. Supported Tape Drives 50 Table 23. PowerEdge R210 Rail Information 52 Table 24. Supported Microsoft Operating Systems 53 Table 25. Supported Linux Operating Systems 54 Table 26. Supported Virtualization OS 55 Table 27. Unified Server Configurator Features and Description 58 Table 28. Features List for BMC, iDRAC6, and vFlash 59 Table 29. USB Controller Priorities 61 Table 30. External Storage 62 Table 31. AMF Single Pack Dimensions and Weights 63 Table 32. EMF Single Pack Dimensions and Weights 63 Table 33. PowerEdge R210 Volatility 66 Table 34. Volatility: Data Writing and Purpose 68 Table 35. Methodology for Data Input to Memory 69 Table 36. Methodology for Memory Protection and Clearing 71
Figure 1. Server Dimensions 17 Figure 2. Front Panel View 17 Figure 3. Back Panel View 18 Figure 4. Power Button LED 18 Figure 5. Side View 19 Figure 6. Internal Chassis View 20 Figure 7. R210 Static Rails 21 Figure 8. R210 Mounted In Four-Post Square-Hole Rack 21 Figure 9. System Fans 22 Figure 10. Intrusion Switch 23 Figure 11. Internal USB Ports 24 Figure 12. Battery on Motherboard 25 Figure 13. PCIe x16 Riser Card 43 Figure 14. SAS 6/iR Adapter Card Installed 44 Figure 15. Rack Adjustability Range 52 Figure 16. Packaging 64

Dell aims to add value to your business by including the features you need without a lot of the unnecessary extras. Our goal is to deliver value through tailored solutions based on industry standards, as well as purposeful, innovative design of our servers.
The Dell™ PowerEdge™ R210 was developed with a purposeful design, energy-optimized technology, simplified systems management, and the flexibility that make it a great first rack server for the small business or as a specialized application server or edge server for larger corporations. Dell’s entry 1-socket 1U rack server, the PowerEdge R210, offers value, the performance of Intel® Xeon® 3400 series processors, DDR3 memory, eSATA external storage expandability, and enterprise-class manageability in an ultra-compact chassis.
Purposeful Design: The PowerEdge R210 follows the 11th generation PowerEdge portfolio specifications and features the same system design commonality and reliability true to the entire portfolio. All 11th generation PowerEdge servers are built to make the user experience easier. We put all external ports, power supplies, and LED lights in the same location for familiar experience as well as easy installation and deployment.
Robust, metal hard drive carriers and organized cabling are designed to help improve component access and airflow across the server. The PowerEdge R210’s design also provides a LED display positioned on the front of the server for ease of monitoring and troubleshooting condition of the server. It was designed to meet the needs of many IT environments with a short 15.5 inch chassis to allow for flexible deployment almost anywhere, including space- constrained environments.
Energy Efficiency: The PowerEdge R210 incorporates Energy Smart design using a low 250 watt power supply, low-flow fans and logical component layout of the internal components which aids with airflow direction, helping to keep the server cool and reduce noise as much as possible. The result is a server with the smallest power footprint within the 11th generation PowerEdge server portfolio.
Simplified System Management: With the optional advanced embedded systems management capabilities of Lifecycle Controller, Dell brings comprehensive enterprise class manageability into the 1-socket space. Lifecycle Controller is delivered as part of the optional iDRAC Express or iDRAC Enterprise in the PowerEdge R210. The Lifecycle Controller helps to simplify administrator tasks by performing a comprehensive set of provisioning functions such as system deployment, system updates, hardware configuration and diagnostics from a single intuitive interface called Unified Server Configurator (USC) in a pre-OS environment. This helps eliminate the need to use and maintain multiple pieces of disparate CD/DVD media.
Also part of the Dell OpenManage™ portfolio is the Dell Management Console which is included with every Dell server and provides IT administrators with a consolidated console view of their IT infrastructure.
Built with cost-effective RAID options to further protect your valuable data, new eSATA external storage connectivity options, and the latest Intel® Xeon® processor technology, the PowerEdge R210 is an ideal entry 1 socket 1U rack for small businesses and larger offices needing flexibility and manageability in a very small chassis.

Feature R210 R200 (Predecessors)
R310 (Next level up)
Processor Quad-core Intel® Xeon® processor 3400 series Dual-core Intel® Celeron® G1101 Dual-core Intel® Pentium® G6950 Dual-core Intel® Core i3 530 Dual-core Intel® Core i3 540 processors
Single Quad-Core Intel® Xeon® 3300 series Single Dual-Core Intel® Xeon® E3100 series Single Quad-Core Intel® Xeon® 3200 series Single Dual-Core Intel® Xeon® 3000 series Single Intel® CoreTM 2 Duo® E4000 series Single Intel® CoreTM 2 Duo® E7000 series Single Intel® Pentium® Dual-Core E2000 series Single Intel® Celeron® E1000 and 400 series
Quad-core Intel® Xeon® processor 3400 series Dual-core Intel® Celeron® G1101 Dual-core Intel® Pentium® G6950 Dual-core Intel® Core i3 530 Dual-core Intel® Core i3 540 processors
Front Side Bus DMI 1333MHz DMI @2.5 Gb/s
# Processors 1 1 1
# Cores Dual or Quad Dual or Quad Dual or Quad
L2/L3 Cache 4MB or 8MB 512K~6M Intel® Xeon®: 8M DT proc: 4, 3 or 2M
Chipset Intel® 3420 chipset Intel® 3210 chipset+ICH9R
Intel® 3420 chipset
DIMMs 4 DDR3 Unbuffered w/ECC 1333/1066 MHz
4 DDR2 Unbuffered w/ECC 800/ 667MHz
6 DDR3 Unbuffered w/ECC or Registered w/ECC 1333/1066MHz
Min/Max RAM 1GB/16GB 512MB/8GB 1GB/32GB
HD Bays 2 x 3.5” or 2 x 2.5” 2 x 3.5” 4 x 3.5” Optional Hot-Swap Support 2.5" HDDs via Hot-Swap tray
HD Types Default SATA. Optional SAS and SSD via add-in controller
Default SATA. Optional SAS via add- in controller
Default SATA. Optional SAS and SSD via add-in controller
Ext Drive Bay(s) 1 for slim ODD 1 for slim ODD 1 for slim ODD

Feature R210 R200 (Predecessors)
R310 (Next level up)
Chipset based SATA Chipset based SATA Chipset based SATA
NON-RAID: SAS 5/E LSI 2032 (For TBU only) RAID: SAS 6/iR Adapter PERC S100 PERC S300 PERC H200 PERC 6/E PERC H800
NON-RAID: SAS HBA LSI 2032 (For TBU only), PERC H800 RAID: SAS 6/iR Modular PERC H200 (6Gb/s) PERC H700 (6Gb/s) with 512MB PERC H700 (6Gb/s) NV DRAM with 512MB or 1G PERC S100 (software based) PERC S300 Modular (software based)
Availability ECC Memory, ADD-in RAID, TPM/CTPM
ECC memory, Add-in RAID, toolless chassis
Hot-swap HDD; Redundant PSU; Quad-pack LED diagnostic/LCD with Hot-swap HDD chassis ;ECC Memory
Server Mgt. BMC, IPMI 2.0 compliant; Full Dell™ OpenManage™ suite Optional; iDRAC6 Express, iDRAC6 Enterprise, vFlash
DRAC4 Full Dell™ OpenManage™ suite
BMC, IPMI 2.0 compliant; Full Dell™ OpenManage™ suite Optional; iDRAC6 Express, iDRAC6 Enterprise, vFlash
I/O Slots 1 x PCIe x16 (True x16, Gen2); full height, half length Support x16 bandwidth card under 25W
Riser 1: One PCIex 8, one PCIe x4 (w/ x8 connector) Riser 2: One PCI-X 64/133 and one PCIe x8
Riser 1: PCIe x16 (x8 routing), Full Height/ Half Length, Gen 2 Riser 2: PCIe x8 (x8 routing), Full Height / Half Length, Gen 2 2 PCIe G2 slots: Slot 1: PCIe x16 (x8
Embedded HD Controller · Optional Storage Controller


NIC/LOM 2x GbE LOM w/o TOE Optional: various NIC available
Power Supplies Non-redundant, 250W (80+ Bronze) Auto Ranging (100V~240V)
Non-redundant, 350W (80+ Bronze) Optional redundant, 400W (80+ Silver) Auto Ranging (100V~240V)
Dimensions (HxWxD) 42.6 x 431 x 393.7 (mm) (w/o ear and bezel) 1.67” x 17.1” x 15.5”
42.67 x 447.0 x 546.1 (mm) (w/o ear and bezel) 1.68” x 17.6” x 21.5”
42.4 x 434.0 x 610 (mm) ( w/o bezel) 1.67” x 17.10” x 24.00”

A number of new technologies are used in the PowerEdge R210, including:
2.2.1 System Management
The PowerEdge R210 supports iDRAC6 Express and Enterprise for advanced manageability. For more information on iDRAC 6 options, please see Section 16, Systems Management.
Dell PowerEdge RAID controller portfolio now offers Enterprise Software RAID in the PERC S100 and PERC S300 options. PERC S100 and S300 are supported in PowerEdge 11th generation value-based servers. Software RAID code uses the CPU of the computer system to execute the RAID tasks including leveraging the CPUs (calculating power as well as sharing memory), internal bus resources, operating system, and all associated applications. Software-based RAID uses drives which are attached to the computer system via a built-in I/O interface or a processor-less host bus adapter (HBA). The RAID function becomes active as soon as the operating system has loaded the RAID driver software. Previous generations of PERC controllers have been based on Hardware RAID technology, the PERC S100 and PERC S300 are based on Software RAID technology. The software based RAID options provide a cost effective entry-level RAID. Both the PERCS100 and S300 versions offer similar RAID level support, including RAID 0, 1, 5, 10. In the case of the PERC S100, it offers a minimal RAID option where the I/O Controller Hub (ICH) chipset of the motherboard enables a SATA RAID option. There is no new hardware involved. The PERC S100 controller solution supports up to 4 cabled SATA Hard Disk Drives (HDD) or Solid State Disk (SSD) drives and is ideal for SMB usage scenarios. For the PERC S300, the hardware component of the controller is based on the Dell SAS HBA (leveraging SAS 6/iR) and allows for both SAS and SATA connectivity. PERC S300 controller solution supports up to 8 cabled or hot plug SAS/SATA Hard Disk Drives (HDDs).

Interface 3Gb SATA (SATA II)
3Gb SAS/SATA (SAS 1.1)
I/O Controller Intel® ICH10R Dell 3Gb/s SAS Adapter (2 internal connectors with x4 SAS ports)
Cache Memory N/A N/A
Battery-backed cache No No
Max Number of Physical Drives
HDD Support SATA (Cabled)
SAS & SATA (Cabled or hot plug)
SSD Support SATA (Cabled)
SED Support Not Supported Not Supported
RAID Levels 0, 1, 5, 10 0, 1, 5, 10
Non-RAID Volumes Yes Yes
Max Number of Virtual Disks per Controller
Operating System Support (Windows Server Only)
Microsoft® Windows Server® 2003 R2 SP2, 32/64-bit, Standard & Enterprise Editions* Microsoft® Windows Server® 2003 R2 SP2 32-bit Web Edition Microsoft® Windows Server® 2008 SP2, 32/64-bit, Standard & Enterprise Editions Microsoft® Windows Server® 2008 R2, 64-bit, Web, Standard, and Enterprise Editions
Microsoft® Windows Server® 2003 R2 SP2, 32/64-bit, Standard & Enterprise Editions* Microsoft® Windows Server® 2003 R2 SP2 32-bit Web Edition Microsoft® Windows Server® 2008 SP2, 32/64-bit, Standard & Enterprise Editions Microsoft® Windows Server® 2008 R2, 64-bit, Web, Standard, and Enterprise Editions
Not Supported Not Supported
Storage Management OpenManage™ 6.2 or later OpenManage 6.2™ or later

up-to-date information, see the Operating System Support Matrix for Dell PowerEdge Systems on Dell.com.
External Serial Advanced Technology Attachment (eSATA) serves as an external interface for SATA technologies. For customers who want fast (up to 1.5Gbit/s), easy- to-use external storage that has advanced features such as S.M.A.R.T. (Self- Monitoring, Analysis, and Reporting Technology) protection, eSATA may be a good choice.
eSATA devices are not bootable when BIOS is set to RAID mode and are not supported as a part of Virtual Disks when in RAID mode for S100.
To operate eSATA devices in the Red Hat® Enterprise Linux® 4.8 environment, the BIOS mode must be manually switched from default (AHCI mode) to ATA mode.
Mode Bootable Hot-Pluggable Restrictions
ATA mode Yes No
AHCI mode Yes Yes RHEL 4.8 is not supported.
RAID mode (S100 enabled)
No No Linux and Virtualization OS are not supported

Processors Quad-core Intel® Xeon® 3400 series processors Dual-core Intel® Celeron® G1101 Dual-core Intel® Pentium® G6950 Dual-core Intel® Core™ i3 530 Dual-core Intel® Core™ i3 540 processors
Front Side Bus or HyperTransport
DMI (Direct Media Interface)
Chipset Intel® 3420 chipset
Memory Up to 16GB (4 U-DIMMs): 1GB/2GB/4GB DDR3 1066MHz or 1333MHz
I/O Slots 1 PCIe x16 G2 slot
RAID Controllers Internal Controllers: SAS 6/iR PERC S100 (software-based) PERC S300 (software-based) PERC H200 External Controllers: PERC 6/E with 256MB or 512MB of battery-backed cache SAS 5/E PERC H800 LSI2032 PCIe SCSI HBA
Hard Drives 3.5 inch SATA (7.2K rpm): 160GB, 250GB, 500GB, 1TB, 2TB 3.5 inch Near-line SAS (7.2 rpm): 1TB, 2TB 3.5 inch SAS (10K rpm): 600GB 3.5 inch SAS (15K rpm): 146GB, 300GB, 450GB, 600GB 2.5 inch SAS (10K rpm): 146GB, 300GB
1 Broadcom® NetXtreme™ 5709 with Dual Port Gigabit Ethernet NIC, Copper, w/TOE PCIe x4 Broadcom® NetXtreme™ 5709 Dual Port Gigabit Ethernet NIC, Copper, TOE/ISCI PCIe x4

Intel® PRO/ 1000PT Single Port Adapter, Gigabit Ethernet NIC, PCIe x1 Intel® Gigabit ET Dual Port Adapter, Gigabit Ethernet NIC, PCIe x4 Intel® Gigabit ET Quad Port Adapter, Gigabit Ethernet NIC, PCIe x4
Power Supply Single-cabled power supply (250W)
Availability Quad-pack LED diagnostics, ECC Memory, add-in RAID, TPM/C- TPM
Video Matrox® G200eW w/ 8MB memory
Remote Management iDRAC6 optional
Systems Management BMC, IPMI 2.0 compliant Dell™ OpenManage™ featuring Dell Management Console Unified Server Configurator Lifecycle Controller enabled via optional: iDRAC6 Express, iDRAC6 Enterprise and vFlash
Rack Support Support for Static ReadyRails™ 4-post and 2-post racks
Operating Systems Microsoft® Factory Installed OS Options: Microsoft® Windows® Small Business Server 2008, 64-bit Standard and Premium Edition Microsoft® Windows Server® 2003 R2 with SP2 32-bit Standard and Enterprise Edition Microsoft® Windows Server® 2003 R2 with SP2 64-bit, Standard and Enterprise Editions Microsoft® Windows Server® 2008 32-bit, Web, Standard and Enterprise Edition Microsoft® Windows Server® 2008 64-bit, Web, Standard and Enterprise Editions Microsoft® Windows Server® 2008 SP2 32-bit, Web, Standard and Enterprise Edition Microsoft® Windows Server® 2008 SP2 64-bit, Web, Standard and Enterprise Edition Microsoft® Windows Server® 2008 R2 64-bit Web, Standard and Enterprise Edition Microsoft® Windows Server® 2008 Foundation Microsoft® Windows Server® 2008 Foundation R2 Microsoft® Non- Factory Installed OS Option: Microsoft® Windows® Essential Business Server 2008 64-bit Standard and Premium Edition Factory Installed Linux OS Options: Novell® SUSE® Linux® Enterprise Server 11 Red Hat® Enterprise Linux® 5.3 Virtualization OS Option: Microsoft® Windows Server® 2008, with Hyper-V™
Feature Product Description

The PowerEdge R210 is a 1-socket 1U server. The configuration details are as follows:

1.68” x 17” x 15.5” (42.6 x 431 x 393.7 mm)
Measurements in Table 6 correspond to the diagram shown in Figure 1 below.

434.0 482.58 42.4 N/A N/A 31.35 NA 393.7 397.49 5.95


* Zb goes to the nominal rear wall external surface where the motherboard I/O connectors reside.



4.5 Power Supply Indicators
4.5.1 Power Button LED
The Power button controls the system's power, turning the unit on and off.
All PowerEdge servers have the Power LED light-pipe integrated in the Power button. The color of the power LED is green. The lighting pattern must be in the form of a standard Power icon.

4.5.2 System Status/ID LED
The System Status/ID LED, present on non-modular rack-dense and rackable tower PowerEdge servers, has the following states:
This LED remains powered during non-operational (standby, shutdown) modes to enable system identification.
See the Hardware Owner’s Manual for information.





ReadyRails™ static rails for tool-less mounting in 4-post racks with square or unthreaded round holes or tooled mounting in 4-post threaded and 2-post racks
The R210 rails must first be attached to the sides of the system and then inserted into the cabinet members installed in the rack. For additional information regarding rail options for the R210, see Section 13.



There are three system fans located in the middle of the system.

4.11 Control Panel LED
See the Hardware Owner’s Manual for information.
4.12.1 Top Cover Lock Mechanism
The PowerEdge R210 uses a coin lock on the top cover. This lock must be unlocked and the cover removed to access the internal components.
The bezel lock is located on the front of the bezel and provides security for the system by preventing access to optical disk drives and the Power button.
The PowerEdge R210 uses a TPM 1.2 compliant encryption chip solution on the system board with BIOS support worldwide, except for China where Trusted Computing Module (TCM) is the standard. TPM is disabled by default.


The LED control panel is designed so the power switch cannot be accidentally turned on or off. In addition, in BIOS there is an optional setting in the CMOS setup to disable the power switch.
The intrusion switch snaps into the chassis located under the side cover. The intrusion switch detects and alerts the user that the side cover is open.


BIOS has the ability to enter a secure boot mode via setup. This mode includes the option to lock out the power and NMI switches on the control panel or set up a system password. See the BIOS specification in the Hardware Owner’s Manual for information.
The PowerEdge R210 has two internal USB ports.

4.14 Battery
A replaceable lithium battery (CR2032) is mounted on the motherboard to provide backup power for the real-time clock and CMOS RAM in the Platform Controller Hub (PCH).


4.15 Field Replaceable Units (FRU)
The planar contains a 16K x 8 serial EEPROM to store FRU information including Dell part number, part revision level, and serial number. This information is used by the SEL (system event log) and the BMC (baseboard management controller).
Parts available for field replacement include:
See the Hardware Owner’s Manual.

The base system includes a single 250W power supply. This unit provides power to the planar and the two internal hard drive bays. Power will be “soft-switched” allowing power cycling using a switch on the front of the system enclosure or through software control (server management functions). The power system is compatible with industry standards, such as ACPI and Server 2000.
Standard VRD (Voltage Regulator Down) modules that conform to VRD11.1 specification are used. This reduces the board layout complexity while offering design modularity. As processor speeds increase, a newer VRD can be used to accommodate the power increase with no need to re-spin the board. The VRD is integrated onto the planar and is not field upgradeable.
There are 2 separate power supply connectors on the planar. One connector is an ATX connector (2x12) and the other one is a 2x2 connector to provide an additional two pins for +12V. The connector Pin definition (2 x 12 power connector) is not ATX standard.
The 2x12 connector provides 3.3V, 5V, 12V, and 12V standby to the system. (3.3V standby to system is generated from 12V standby).



5.3.1 Temperature
Operating: 10° to 35°C (50° to 95°F) with a maximum temperature gradation of 10°C per hour (NOTE: For altitudes above 2950 feet, the maximum operating temperature is de-rated 1ºF/550 ft.)
Storage: –40° to 65°C (–40° to 149°F) with a maximum temperature gradation of 20°C per hour
Operating: One shock pulse in the positive z axis (one pulse on each side of the system) of 31 G for 2.6 ms in the operational orientation
Storage: Six consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 71 G for up to 2 ms
Six consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 32 G faired square wave pulse with velocity change at 270 inches/second (686 centimeters/second)
Operating: 16 to 3048 m (–50 to 10,000 ft) (Note: For altitudes above 2950 feet, the maximum operating temperature is de-rated 1ºF/550 ft.)


Dimensions L-2101 mm x W-106 mm x H-40.0 mm
AC Cord Rating 15 Amps @ 120 VAC, 10 Amps @ 240 VAC
Under typical line conditions and over the entire system ambient operating range, the inrush current may reach 25 Amps for 10 ms or less.
Efficiency 20% to 100% Load 82–85% @115 VAC 82–85% @ 230 VAC
1 Does not include the power supply handle or ejection tab
See the ENERGY STAR Compliance results on Dell.com.
The thermal design of the PowerEdge R210 reflects the following:

The acoustical design of the PowerEdge R210 reflects the following:

Standby: AC Power is connected to Power Supply Units but system is not turned on.
Idle: Reference ISO7779 (1999) definition 3.1.7; system is running in its OS but no other specific activity.
Stressed Processor: An operating mode per ISO7779 (1999) definition 3.1.6. The software MemBW4 is activated to stress the processors.
LwA–UL: The upper limit sound power level (LwA) calculated per section 4.4.2 of ISO 9296 (1988) and measured in accordance to ISO 7779 (1999).
LpA: A-Weighted sound pressure level. The system is placed in a rack with its bottom at 75 cm from the floor. The acoustic transducer is at front bystander position, ref ISO7779 (1999) Section 8.6.2.
Prominent tone: Criteria of D.5 and D.8 of ECMA-74 9th ed. (2005) are followed to determine if discrete tones are prominent. The system is placed in a rack with its

bottom at 75 cm from the floor. The acoustic transducer is at front bystander position, ref ISO7779 (1999) Section 8.6.2.

The PowerEdge R210 is a 1S, entry-level server based on the Intel FCLGA1156 to support Intel Xeon 3400 series and Core i3 processors.

The PowerEdge R210 is a single socket 1U rack server that operates in single processor mode only. The memory controller is embedded in the processor.

Features of the PowerEdge R210 memory include:
The following DIMMs are supported by the PowerEdge R210:

1GB 1066 1066 UDIMM 1 X8
1GB 1333 1333 UDIMM 1 X8
2GB 1066 1066 UDIMM 1 2 1,2 1 X8
2GB 1333 1333 UDIMM 1 2 1,2 1 X8
4GB 1066 1066 UDIMM 1 4 1,2,3,4 1 X8
4GB 1066 1066 UDIMM 2 2 1,2 2 X8
4GB 1333 1333 UDIMM 1 4 1,2,3,4 1 X8
4GB 1333 1333 UDIMM 2 2 1,2 2 X8
8GB 1066 1066 UDIMM 2 4 1,2,3,4 2 X8
8GB 1066 1066 UDIMM 4 2 1,2 2 X8
8GB 1333 1333 UDIMM 2 4 1,2,3,4 2 X8
8GB 1333 1333 UDIMM 4 2 1,2 2 X8
16GB 1066 1066 UDIMM 4 4 1,2,3,4 2 X8


16GB 1333 1333 UDIMM 4 4 1,2,3,4 2 X8
2GB 1066 1066 UDIMM 2 1 1 2 X8
2GB 1333 1333 UDIMM 2 1 1 2 X8
4GB 1066 1066 UDIMM 4 1 1 2 X8
4GB 1333 1333 UDIMM 4 1 1 2 X8
The PowerEdge R210 planar provides four 72-bit (240-pin) sockets for DIMM memory modules. These modules are DDR3-800/1066/1333 Unbuffered DDR SDRAM DIMMs. The modules are configured as 72 bits wide to provide for ECC. The memory controller in the CPU performs the ECC. The system supports a minimum of 1GB upgradeable to 16 of RAM, using the following DIMM sizes:
The PowerEdge R210 supports 1066/1333MHz DDR3 memory.
Not supported.
Not supported.
Memory RAID is not supported.

The PowerEdge R210 planar incorporates the Intel Ibex Peak as PCH chipset. The Ibex Peak is a highly integrated I/O controller. The high-level features supported by the chipset and implemented on the PowerEdge R210 are detailed in the sections that follow.
Direct Media Interface (DMI) is the chip-to-chip connection between the processor and Ibex Peak chipset. This high-speed interface integrates advanced priority-based servicing allowing for concurrent traffic and true isochronous transfer capabilities. Base functionality is completely software-transparent, permitting current and legacy software to operate normally.
The Ibex Peak provides up to 8 PCI Express Root Ports, supporting the PCI Express Base Specification, Revision 2.0. Each Root Port supports 2.5 GB/s bandwidth in each direction (5 GB/s concurrent). PCI Express Root Ports 1-4 can be statically configured as four x1 Ports or ganged together to form one x 4 ports. Ports 5 and 6 can only be used as two x 1 port.
The Ibex Peak has two integrated SATA host controllers that support independent DMA operation on up to six ports and supports data transfer rates of up to 3.0 GB/s (300MB/s). The SATA controller contains two modes of operation – a legacy mode using I/O space, and an AHCI mode using memory space. Software that uses legacy mode will not have AHCI capabilities.
The Ibex Peak supports the Serial ATA Specification, Revision 1.0a. The Ibex Peak also supports several optional sections of the Serial ATA II: Extensions to Serial ATA 1.0 Specification, Revision 1.0 (AHCI support is required for some elements).
The Ibex Peak provides hardware support for Advanced Host Controller Interface (AHCI), a new programming interface for SATA host controllers. Platforms supporting AHCI may take advantage of performance features such as no master/slave designation for SATA devices—each device is treated as a master—and hardware-assisted native command queuing. AHCI also provides usability enhancements such as Hot-Plug. AHCI requires appropriate software support (e.g., an AHCI driver) and for some features, hardware support in the SATA device or additional platform hardware.
The Ibex Peak PCI interface provides a 33 MHz, Revision 2.3 implementation. The Ibex Peak integrates a PCI arbiter that supports up to four external PCI bus masters in addition to the internal Ibex Peak requests. This allows for combinations of up to four PCI down devices and PCI slots.

The Ibex Peak implements an LPC Interface as described in the LPC 1.1 Specification. The Low Pin Count (LPC) bridge function of the Ibex Peak resides in PCI Device 31:Function 0. In addition to the LPC bridge interface function, D31:F0 contains other functional units including DMA, interrupt controllers, timers, power management, system management, GPIO, and RTC.
The Ibex Peak implements an SPI Interface as an alternative interface for the BIOS flash device. An SPI flash device can be used as a replacement for the FWH, and is required to support Gigabit Ethernet, Intel® Active Management Technology and integrated Intel Quiet System Technology. The Ibex Peak supports up to two SPI flash devices with speed up to 20 MHz, 33 MHz utilizing two chip select pins.
The DMA controller incorporates the logic of two 82C37 DMA controllers, with seven independently programmable channels. Channels 0–3 are hardwired to 8-bit, count-by-byte transfers, and channels 5–7 are hardwired to 16-bit, count-by-word transfers. Any two of the seven DMA channels can be programmed to support fast Type-F transfers.
Channel 4 is reserved as a generic bus master request.
The Ibex Peak supports LPC DMA, which is similar to ISA DMA, through the Ibex Peak’s DMA controller. LPC DMA is handled through the use of the LDRQ# lines from peripherals and special encoding on LAD[3:0] from the host. Single, Demand, Verify, and Increment modes are supported on the LPC interface.
The timer/counter block contains three counters that are equivalent in function to those found in one 82C54 programmable interval timer. These three counters are combined to provide the system timer function, and speaker tone. The 14.31818 MHz oscillator input provides the clock source for these three counters.
The Ibex Peak provides an ISA-Compatible Programmable Interrupt Controller (PIC) that incorporates the functionality of two, 82C59 interrupt controllers. The two interrupt controllers are cascaded so that 14 external and two internal interrupts are possible. In addition, the Ibex Peak supports a serial interrupt scheme.
All of the registers in these modules can be read and restored. This is required to save and restore system state after power has been removed and restored to the platform.
In addition to the standard ISA compatible Programmable Interrupt controller (PIC) described in the previous section, the Ibex Peak incorporates the Advanced Programmable Interrupt Controller (APIC).
The Ibex Peak contains up to two Enhanced Host Controller Interface (EHCI) host controllers that support USB high-speed signaling. High-speed USB 2.0 allows data transfers up to 480 Mb/s which is 40 times faster than full-speed USB. The Ibex Peak also contains up to seven Universal Host Controller Interface (UHCI) controllers that support USB full-speed and low-speed signaling.
The Ibex Peak supports up to fourteen USB 2.0 ports. All fourteen ports are high-speed, full- speed, and low-speed capable. Ibex Peak’s port-routing logic determines whether a USB port is controlled by one of the UHCI or EHCI controllers.

The Ibex Peak contains a real-time clock with 256 bytes of battery-backed RAM.
The real-time clock performs two key functions: keeping track of the time of day and storing system data, even when the system is powered down. The RTC operates on a 32.768 KHz crystal and a 3 V battery.
The RTC also supports two lockable memory ranges. By setting bits in the configuration space, two 8-byte ranges can be locked to read and write accesses. This prevents unauthorized reading of passwords or other system security information.
The RTC also supports a date alarm that allows for scheduling a wake up event up to 30 days in advance, rather than just 24 hours in advance.
Various general purpose inputs and outputs are provided for custom system design. The number of inputs and outputs varies depending on Ibex Peak configuration.
The Ibex Peak’s power management functions include enhanced clock control and various low- power (suspend) states (e.g., Suspend-to-RAM and Suspend-to-Disk). A hardware-based thermal management circuit permits software-independent entrance to low-power states. The Ibex Peak contains full support for the Advanced Configuration and Power Interface (ACPI) Specification, Revision 3.0a.
In addition to Intel AMT, the Ibex Peak integrates several functions designed to manage the system and lower the total cost of ownership (TCO) of the system. These system management functions are designed to report errors, diagnose the system, and recover from system lockups without the aid of an external microcontroller.
The Ibex Peak’s integrated programmable TCO (Total Cost of Ownership) timer is used to detect system locks. The first expiration of the timer generates an SMI# that the system can use to recover from a software lock. The second expiration of the timer causes a system reset to recover from a hardware lock.
The Ibex Peak looks for the processor to fetch the first instruction after reset. If the processor does not fetch the first instruction, the Ibex Peak will reboot the system.
When detecting an ECC error, the host controller has the ability to send one of several messages to the Ibex Peak. The host controller can instruct the Ibex Peak to generate an SMI#, NMI, SERR#, or TCO interrupt.

The Ibex Peak provides the ability to disable the following integrated functions: LAN, USB, LPC, Intel HD Audio, SATA, PCI Express or SMBus. Once disabled, these functions no longer decode I/O, memory, or PCI configuration space. Also, no interrupts or power management events are generated from the disabled functions.
Intruder Detect. The Ibex Peak provides an input signal (INTRUDER#) that can be attached to a switch that is activated by the system case being opened. The Ibex Peak can be programmed to generate an SMI# or TCO interrupt due to an active INTRUDER# signal.
The Ibex Peak contains an SMBus Host interface that allows the processor to communicate with SMBus slaves. This interface is compatible with most I2C devices. Special I2C commands are implemented.
The Ibex Peak’s SMBus host controller provides a mechanism for the processor to initiate communications with SMBus peripherals (slaves). Also, the Ibex Peak supports slave functionality, including the Host Notify protocol. Hence, the host controller supports eight command protocols of the SMBus interface (see System Management Bus
(SMBus) Specification, Version 2.0): Quick Command, Send Byte, Receive Byte, Write Byte/Word, Read Byte/Word, Process Call, Block Read/Write, and Host Notify.
Ibex Peak’s SMBus also implements hardware-based Packet Error Checking for data robustness and the Address Resolution Protocol (ARP) to dynamically provide address to all SMBus devices.
The Ibex Peak introduces a new hardware-based security technology which encrypts data stored on any SATA compliant HDD in AHCI Mode. This feature gives the end-user the ability to restrict access to HDD data by unknown parties. Intel Anti-Theft Technology can be used alone or can be combined with software encryption applications to add protection against data theft.
Intel Anti-Theft Technology functionality requires a correctly configured system, including an appropriate processor, Intel Management Engine firmware, and system BIOS support.
The Ibex Peak provides hardware support for implementation of Intel Virtualization Technology with Directed I/O (Intel VT-d). Intel VT-d Technology consists of technology components that support the virtualization of platforms based on Intel Architecture Processors. Intel VT-d Technology enables multiple operating systems and applications to run in independent partitions. A partition behaves like a virtual machine (VM) and provides isolation and protection across partitions. Each partition is allocated its own subset of host physical memory.

Ibex Peak adds the industry standard JTAG interface and enables Boundary-Scan in place of the XOR chains used in previous generations of the Ibex Peak. Boundary-Scan can be used to ensure device connectivity during the board manufacturing process. The JTAG interface allows system manufacturers to improve efficiency by using industry available tools to test the Ibex Peak on an assembled board. Since JTAG is a serial interface, it eliminates the need to create probe points for every pin in an XOR chain. This eases pin breakout and trace routing and simplifies the interface between the system and a bed-of-nails tester.

The following features are supported by BIOS:

NO S1, S2, S3 (STR) support.
S4 will be supported by OS support only.
Wake Up Events States Can Wake From
Power Button S5, OS-S4
WOL S5, OS-S4
9.3 Power Management Modes
9.3.1 Dell Active Power Controller
The Dell Active Power Controller (DAPC) is a Dell proprietary implementation that provides improved performance/watt over the OS implementation of Intel’s DBS. DAPC is implemented in system BIOS and uses hardware level counters, etc. to determine hardware utilization. The BIOS uses this information to determine when to change the processor’s operating frequency. The DAPC is OS independent and means that the OS no longer has control. This provides a consistent power management solution regardless of the installed OS. Some OS(s), particularly hypervisors, do not support power management, thus DAPC provides a solution when there otherwise would not be one.

Intel processors support Demand Based Switching (DBS) which enables the processor to dynamically change its operating frequency in response to workload changes. The industry standard implementation of this power management feature is in the Operating System (OS). The OS monitors process/thread level utilization of the processor and uses processor controls to change the processor’s operating frequency. For heavy workloads, the OS will run the processor at higher frequencies for additional performance. Lighter workloads do not need high performance, thus the OS will run the processor at lower frequencies.
The Maximum Performance Mode disables power management. In this mode, the processor frequency is statically set to the highest supported frequency.
The power management features are implemented via two categories: fixed or generic. Fixed features use bits defined in the ACPI specification for specific capabilities. The fixed feature bits give the OS complete control over the power management of a device since the location of the bits is given to the OS in the FACP table. Thus, a driver can directly access bits to control a device’s power management. Generic features have defined enable and status bits, but the functionality is not fully visible to the OS. Dell provides ASL code to handle the details of generic features, allowing the OS to intelligently communicate with system-specific hardware.
Feature Type Enable/Status /Ctrl bit location
Fixed PCH The OS uses the SCI_EN bit to switch from legacy mode to ACPI mode.
Sleep states Fixed PCH Supported states: S0(Working), S4-OS (‘Hibernation’ in W2K), and S5 (Soft-off).
S1 (also called ‘standby’ or ‘suspend’) and S3 are not supported.
Power Button Fixed PCH In ACPI mode, OS has control of the power button. In non-ACPI mode, SMI handler owns power button events.
Fixed PCH The OS is able to configure the system to wake on the RTC alarm.
Power Mgmt. Timer
Fixed PCH 24-bit power management timer is used.
Power Mgmt. Event (PME)
Generic PCH Each host bus’s PME# signal is routed to a separate general-purpose event pin in the chipset. When a device signals PME#, the system wakes (if necessary), the OS detects the event, and a Dell defined ASL routine handles the event. Wake-on-LAN is one example of a PME.
Description · ACPI mode switch · Real-Time Clock

USB wake Generic N/A This feature is not supported on this system since the S1 state is not supported.
DBS N/A Processor MSRs
This feature does P state transition under Windows
N/A Processor and PCH registers
This feature allows multiple C state supports for Processor. This feature will work under Windows and ACPI OS that understand C states.
N/A Processor/IMC and PCH chipset registers.
11G Servers will be the most energy smart servers that Dell will ship. In addition to P,C and T states, BIOS will expose the Power Profiles to the OS. Each Power profile will have a specific settings and it will fine tune processor, MCH, IOH and South Bridge. For detailed explanation on how this feature works, please look at BIOS Power Management specification located in Design Docs under R310 engineering.

Maximum Performance DBPM Disabled ( BIOS will set P-State to MAX)
OS Control Enable OS DBPM Control (BIOS will expose
Active Power Controller Enable DellSystem DBPM (BIOS will not make all P states available to OS)
Maximum Performance | Minimum Power | OS DBPM | System DBPM
Maximum Performance |1333Mhz |1067Mhz |800Mhz| Minimum Power Fan Algorithm
C State Support · Power Profile support

The PowerEdge R210 system provides:



10.2 PCI Devices
Xeon 3400 Series CPU PCI devices include:

Core i3/Pentium/Celeron CPU PCI devices include:
PCH and Slots devices include:
The onboard devices are SATA, USB (x4), SMBus, IOxAPIC, and the LOM.
PCI Slot # Mechanical Electrical Height Length
1 PCIe x 16 PCIe x 16 Gen 2 Full Half



Dell™ PERC S300 (SW RAID) PCIe x8 1 1
Dell™ PERC H200 (HW RAID) PCIe x8 1 1
Dell™ PERC 6E Adapter 256MB PCIe x8 1 1
Dell™ PERC 6E Adapter 512MB PCIe x8 1 1
Broadcom® NetXtreme™ II 5709 Dual Port Ethernet PCIe Card with TOE
Broadcom® NetXtreme™ II 5709 Dual Port Ethernet PCIe Card with TOE and iSCSI Offload
Broadcom® NetXtreme™ II BCM5709 Quad Port Ethernet PCIe™ Card with TOE and iSCSI Offload

The PowerEdge R210 supports only 1 PCIe x8 slot.
There is Broadcom 5716 chip on the PowerEdge R210 motherboard. The chip is connected to the PCH via a PCI Express x4 gen2 link. Broadcom 5716 does not support TOE (TCP Offload Engine).
The chip provides two Gigabit Ethernet ports. There are two RJ-45 connectors with integrated magnetic and LED on the rear of the system. The firmware for the LOM chip resides in a flash part.
The PowerEdge R210 supports Wake on LAN (WOL) from either port.
For listing of NICs supported on the R210, please see Section 10.1 Table 24

The PowerEdge R210 supports up to 2 HDDS:
Customer must be selected at point of purchase. This is not an upgrade option for APOS.
HDD Bays 2 x 3.5" or 2 x 2.5” Cabled only
Drive Specifications


Non-Mixed Drives, all SATA, all SSD, or ALL SAS
No HDD 0 NCZCBL No controller/No hard drive 0 0
1 MSTCBL On-board SATA Controller (Ibex Peak) 1 2
SATA Raid 2 MSTR0CBL Embedded SATA SW RAID – RAID0 2 2
3 MSTR1CBL Embedded SATA SW RAID – RAID1 2 2
4 ASSCBL Add-in SAS/SATA RAID card, No RAID (S300)
5 ASSCBL Add-in SAS/SATA RAID card, No RAID (S300) with 2 HDDs
6 ASSR0CBL Add-in SAS/SATA RAID card, RAID 0 (S300) 2 2
7 ASSR1CBL Add-in SAS/SATA RAID card, RAID 1 (S300) 2 2
8 ASSCBL Add-in SAS/SATA RAID card, No RAID (SAS 6/iR /H200 ) 1 2
9 ASSR0CBL Add-in SAS/SATA RAID card, RAID 0 (SAS 6/iR /H200) 2 2
10 ASSR1CBL Add-in SAS/SATA RAID card, RAID 1 (SAS 6/iR/H200 ) 2 2
The PowerEdge R210 will support up to 1 slim type internal optical drive and optional external USB DVD-ROM. The PowerEdge R210 can boot from either the internal optical drive or the optional external drive and supports the following:

PV DAS

Matrox® G200eW w/ 8MB memory integrated in Winbond® WPCM450 (BMC controller):
The PowerEdge R210 does not support audio (sound card or speakers).

The ReadyRails™ static rail system for the R210 provides tool-free support for racks with square or unthreaded round mounting holes (including Dell’s 42xx and 24xx series racks) with an adjustment range of 60–87 cm. The rails also offer tooled mounting support for 4-post threaded and 2-post (Telco) racks for added versatility.
The static rails for the R210 support tool-less mounting in 19”-wide, EIA-310-E compliant square hole and unthreaded round hole racks via Dell’s ReadyRails™ mounting interface. The rails also support a “generic” mounting interface for tooled mounting in threaded hole and 2-post (Telco) racks. Screws are not included in the kit since threaded racks are offered with a variety of thread designations. Users must provide their own screws when mounting the rails in threaded or 2-post racks.

The adjustment range of the rails is a function of the type of rack in which they are being mounted. The min-max values listed below represent the allowable distance between the front and rear mounting flanges in the rack.

A4 ReadyRails™/Generic Static 608 879 594 872 604 890 622 —
The static rails for the R210 support a wide variety of racks and mounting configurations but do not support the ability to extend the system out of the rack for service. Thus, they do not provide support for a cable management arm (CMA).

For the most up-to-date information, see the Operating System Support Matrix for Dell PowerEdge Systems on Dell.com.

Windows Server® 2008 R2 (Windows 7 includes SP2 bits)


Novell® SUSE® Linux® Enterprise S10 SP3

Virtualization OS Install Method
VMware® ESX 4 update 1 DIB
Embedded VMware ESXi 4 update 1
VMWare ESX 3.5.1 Supported; not offered through Dell (No FI nor DIB)
VMWare ESXi 3.5.1 Supported; not offered through Dell (No FI or DIB)
Website download fulfillment; instructions are DIB
PlateSpin® PowerConvert®
Website download fulfillment; instructions are DIB
Download version

Dell delivers open, flexible, and integrated solutions that help you reduce the complexity of managing disparate IT assets by building comprehensive IT management solutions. Combining Dell PowerEdge Servers with a wide selection of Dell-developed management solutions gives you choice and flexibility, so you can simplify and save in environments of any size. To help you meet your server performance demands, Dell offers Dell OpenManage systems management solutions for:
A Dell Systems Management and Documentation DVD and a Dell Management Console DVD are included with the product. Content includes:

The PowerEdge R210 implements circuitry for the next generation of embedded server management. It is Intelligent Platform Management Interface (IPMI) v2.0 compliant. The optional iDRAC (Integrated Dell Remote Access Controller) is responsible for acting as an interface between the host system and its management software and the periphery devices. These periphery devices consist of the PSUs, the storage backplane, integrated SAS HBA or PERC 6/I, and control panel with display.
The optional upgrade to iDRAC6 provides features for managing the server remotely or in data center lights-out environments.
Advanced iDRAC features require the installation of the optional iDRAC6 Enterprise card.
Embedded management is comprised of four key components:
Dell Unified Server Configurator (USC) is a local 1:1 graphical user interface embedded on Lifecycle Controller that aids in local server provisioning in a pre-OS environment. For servers with iDRAC Express, the Lifecycle Controller offers OS install, platform updates, platform configuration, and diagnostics capabilities. For servers without iDRAC6 Express, this utility has limited functionality and offers OS install and diagnostics capabilities only.
To access the Unified Server Configurator, press the key within 10 seconds of the Dell logo’s appearance during the system boot process. Current functionality enabled by the Unified Server Configurator is detailed in the following table.

Faster O/S Installation Drivers and the installation utility are embedded on system
Faster System Updates Integration with Dell support automatically directed to latest versions of the Unified Server Configurator, iDRAC, RAID, BIOS, NIC, and Power Supply
Update Rollback Ability to recover to previous known good state for all updatable components
More Comprehensive Diagnostics Diagnostic utilities are embedded on system
Simplified Hardware Configuration Detects RAID controller and allows user to configure virtual disk and choose virtual disk as boot device, eliminating the need to launch a separate utility. Also provides configuration for iDRAC, BIOS, and NIC/LOM.
The optional iDRAC6 Express is the first tier of iDRAC6 upgrades. In addition to upgrading the system with a Lifecycle Controller, the iDRAC6 Express offers the following key features:
The optional iDRAC6 Enterprise card provides access to advanced iDRAC6 features. The iDRAC6 Enterprise connects directly to the R210 planar and is mounted parallel to the planar with stand-offs.
Key features for the iDRAC6 Enterprise include:
Feature Description

flash partition. A more detailed feature list for iDRAC6 Enterprise and vFlash is included in the following table.




All PowerEdge systems have a minimum of 2 front-accessible USB 2.0 compliant ports with enough spacing around to accommodate full usage of both connectors simultaneously along with any/all other front panel features (Video connector, buttons, LED’s, etc.) without mechanical interference. These ports are connected to the same controller and not shared with internal or back USB ports
For security reasons, all external USB ports must have an enable/disable function.
Disabling USB controllers must observe the hierarchy in Table 29 (listed from lowest to highest priority in a 4 controller design).
Internal USB ports connected to internal persistent storage devices have an enable/disable function independent of the other ports present in the system.
USB Controller Function If Disabled
4 (Lowest) Internal USB peripherals No other Controller is disabled
3 Front USB Controller 4 is disabled as well
2 Back USB Controllers 3 & 4 are disabled as well
1 (Highest) Remote Access (RAC) Controllers 2,3, & 4 are disabled as well
The above hierarchy dictates that connections that are lower in the hierarchy must be disabled anytime a higher level connection is disabled (e.g., when Back USB is disabled the Front USB ports are also disabled).
Optional external USB DVD-ROM.



Options for single pack and multipack are available. Multipack will support 4 units in one pack.
INSIDE DIMENSIONS OUTSIDE DIMENSIONS WEIGHT
System packed out weight:
PowerEdge R210: 9.71 kg (21.42 lbs) Cushion: 0.42 kg (.93 lbs) Corrugated Box: 2.75 kg (6.05 lbs)
INSIDE DIMENSIONS OUTSIDE DIMENSIONS WEIGHT
System packed out weight:
PowerEdge R210: 8.56 kg (18.87 lbs) Cushion: 0.36 kg (.80 lbs) Corrugated Box: 2.06 kg (4.55 lbs)





System BIOS SPI Flash Y SYS_S PI 1 4MB Flash EEPROM (SPI interface)


2 User selectable License key hard set ROM or user choice
vFlash Y J_SD (conne ctor) 1 1GB Secure Digital NAND Flash


Can user programs or operating system write data to it during normal operation?
No for iDRAC Operating System; Yes for Managed System Services Repository
iDRAC Operating System plus Managed System Services Repository (i.e., Unified Server Configurator, OS drivers, diagnostics, rollback versions of various programmables)
No BIOS binding of plug in module to a particular planar.
iDRAC boot loader and configuration (i.e. MAC address), Lifecycle log. nd system event log.
iDRAC6 Boot Block Flash yes Storage of encryption keys
No BIOS binding of plug-in module to a particular planar


Can user programs or operating system write data to it during normal operation?
Internal USB Yes as allowed by OS Normal usage is read only software license key, but not limited
vFlash Yes when enabled, installed, and the media does not have the write protect switch applied
Storage of logs, user images such as files, drivers, and Operating Systems
How is data input to this memory?
System BIOS SPI Flash Loading flash memory requires a vendor-provided firmware file and loader program which is executed by booting the system from a floppy or OS-based executable containing the firmware file and the loader. System loaded with arbitrary data in firmware memory will not operate
Loading flash memory requires a vendor-provided firmware file and loader program which is executed by booting up the system from a floppy or OS based executable containing the firmware file and the loader. LOMs loaded with arbitrary data in firmware memory will not operate.
iDRAC6 Controller RAM iDRAC embedded system
System CPLD Loading flash memory requires a vendor-provided firmware file and loader program which is executed by booting up the system from a floppy or OS-based executable (currently only DRMK utility support) containing the firmware file and the loader. System loaded with arbitrary data in CPLD memory will not operate.
iDRAC6 Express Internal Flash Not used
iDRAC OS: Loading flash memory requires a vendor-provided firmware file and loader program which is executed by booting the system from a floppy or OS-based executable containing the firmware file and the loader. System loaded without a good iDRAC firmware image yields a non-functional iDRAC.
Planar · LOM Configuration Data · System RAM

How is data input to this memory? Managed Services Repository: Various partitions are loaded using vendor-provided firmware file and loader program just like iDRAC OS.
TPM ID EEPROM (Plug- in module only) Factory loaded only
TPM Binding EEPROM (on China planar only) BIOS only
iDRAC6 SDRAM Embedded iDRAC OS for 108MB and 8MB for VGA frame buffer
iDRAC6 FRU Factory and iDRAC embedded OS
iDRAC6 Boot Block Flash
Loading flash memory requires a vendor-provided firmware file and loader program which is executed by booting up the system from a floppy or OS-based executable or out of band firmware updates across the management network. Bad contents yield the iDRAC inoperable and unrecoverable in the customer environment. The lifecycle log is automatically updated by the iDRAC as various system component firmware, hardware, and software versions change.
Using TPM-enabled operating systems; except in China where TCM is used.
CMOS BIOS control only via input such as BIOS F2 menu user configuration settings (such as boot order)
Internal USB Either read only license key or OS control copies
vFlash Preloaded media before installation, or remote out-of-band upload of user data (i.e., ISO images, files) or local server read/write capability to use like a hard disk.


How is this memory write protected? How is the memory cleared?
Not possible with any utilities or applications and system is not functional if corrupted/removed.
No explicitly protected but special applications are needed to communicate through the LOMs to reprogram this ROM
Not possible with any utilities or applications and system is not functional if corrupted/removed.
Writes are proxied through a temporary iDRAC scratchpad RAM and not directly made from an OS or OS application
System RAM OS control Reboot or power down system

TPM Binding EEPROM (on China planar only)
Locked by BIOS from physical access by anyone after boot
Not applicable, BIOS control only
iDRAC6 SDRAM n/a AC cycle for BMC OS and reset/power off server for VGA frame buffer
iDRAC6 FRU writes controlled by iDRAC embedded OS
EPPID is not clearable
iDRAC6 Boot Block Flash
iDRAC embedded OS control of the write protection
Not possible with any utilities or applications and iDRAC does not function as expected if corrupted/removed. Lifecycle log is clearable only in a factory environment; System Event Log is user clearable
SW write protected F2 Setup option
Planar NVRAM_CLR jumper or by removal of AC cord, cover, and coin cell battery, then waiting 30 seconds prior to replacement of battery, cover and AC cord.; F2 system setup option is used to restore defaults
N/A, BIOS only control
Internal USB OS control OS control format
vFlash Media write protection switch or OS control
iDRAC-based format, local OS format, deleted, or card removed and formatted on a client