1 Product Comparisonp.72 New Technologiesp.112.1 Overviewp.112.2 Detailed Informationp.112.2.1 System Managementp.112.2.2 Software RAIDp.112.2.3 eSATAp.133 System Overviewp.144 Mechanicalp.164.1 Chassis Descriptionp.164.2 Dimensions and Weightp.164.3 Front Panel View and Featuresp.174.4 Back Panel View and Featuresp.184.5 Power Supply Indicatorsp.184.5.1 Power Button LEDp.184.5.2 System Status/ID LEDp.184.6 NIC Indicatorsp.184.7 Side Viewp.194.8 Internal Chassis Viewp.204.9 Railsp.214.10 Fansp.224.11 Control Panel LEDp.224.12 Securityp.224.12.1 Top Cover Lock Mechanismp.224.12.2 Bezelp.224.12.3 Trusted Platform Module (TPM)p.224.12.4 Power Switch Securityp.234.12.5 Intrusion Alertp.234.12.6 Secure Modep.244.13 USB Portsp.244.14 Batteryp.244.15 Field Replaceable Units (FRU)p.254.16 User Accessible Jumpers, Sockets, and Connectorsp.255 Power, Thermal, Acousticp.265.1 Power Suppliesp.265.2 Power Supply Connectors on the Planarp.265.3 Environmental Specificationsp.275.3.1 Temperaturep.275.3.2 Relative Humidityp.275.3.3 Maximum Vibrationp.275.3.4 Maximum Shockp.275.3.5 Altitudep.275.3.6 Airborne Contaminant Levelp.275.4 Power Supply Unit (PSU) Specificationsp.285.5 ENERGY STAR® Compliancep.285.6 Thermalp.285.7 Acousticsp.296 Processorsp.316.1 Overviewp.316.2 Supported Processorsp.316.3 Processor Configurationsp.317 Memoryp.327.1 Overviewp.327.2 DIMMs Supportedp.327.3 Slots/Risersp.337.4 Speedp.337.5 Sparingp.337.6 Mirroringp.337.7 RAIDp.338 Chipsetp.348.1 Overviewp.348.2 Direct Media Interfacep.348.3 PCI Express Interfacep.348.4 SATA Interfacep.348.5 AHCIp.348.6 PCI Interfacep.348.7 Low Pin Count (LPC) Interfacep.358.8 Serial Peripheral Interface (SPI)p.358.9 Compatibility Modulep.358.10 Advanced Programmable Interrupt Controller (APIC)p.358.11 USB Interfacep.358.12 Real-Time Clock (RTC)p.368.13 GPIOp.368.14 Enhanced Power Managementp.368.15 System Management Featuresp.368.15.1 TCO Timerp.368.15.2 Processor Present Indicatorp.368.15.3 Error Code Correction (ECC) Reportingp.368.15.4 Function Disablep.378.16 System Management Bus (SMBus 2.0)p.378.17 Intel Anti-Theft Technologyp.378.18 Intel Virtualization Technology for Directed I/Op.378.19 JTAG Boundary-Scanp.389 BIOSp.399.1 Overviewp.399.2 ACPIp.409.3 Power Management Modesp.409.3.1 Dell Active Power Controllerp.409.3.2 Power Saving BIOS Setting (OS Control)p.419.3.3 Maximum Performancep.4110 I/O Slotsp.4310.1 Overviewp.4310.2 PCI Devicesp.4410.3 Boot Orderp.4710.4 NICsp.4711 Storagep.4811.1 Overviewp.4811.2 Drivesp.4811.3 RAID Configurationsp.4911.4 Optical Disk Drive (ODD)p.4911.5 Tape Drivesp.5012 Video and Audiop.5112.1 Videop.5112.2 Audiop.5113 Rack Informationp.5213.1 Overviewp.5213.2 Railsp.5213.3 Cable Management Arm (CMA)p.5214 Operating Systemsp.5315 Virtualizationp.5516 Systems Managementp.5616.1 Overviewp.5616.2 Server Managementp.5616.3 Embedded Server Managementp.5716.4 Lifecycle Controller and Unified Server Configuratorp.5716.5 iDRAC6 Expressp.5816.6 iDRAC6 Enterprisep.5817 Peripheralsp.6117.1 USBp.6117.2 USB Devicep.6117.3 External Storagep.6218 Packaging Optionsp.63
Page 1 of the Dell R210 user manual — Dell PowerEdge R210
Page 1 · click to enlarge
Page 1
Dell R210 diagram (page 1)
Fig. 1

Dell PowerEdge R210

Technical Guide

Dell R210 — Dell PowerEdge R210 diagram (page 1)
Fig. 2 · Dell PowerEdge R210

1-socket 1U rack server providing the features you need without a lot of the unnecessary extras.

Page 2 of the Dell R210 user manual
Page 2 · click to enlarge
Page 2

This document is for informational purposes only. Dell reserves the right to make changes without further notice to any products herein. The content provided is as is and without express or implied warranties of any kind.

Dell, PowerEdge, PowerVault, OpenManage, and ReadyRails are trademarks of Dell, Inc. Citrix® and XenServer™ are trademarks of Citrix Systems, Inc. and/or one or more of its subsidiaries, and may be registered in the United States Patent and Trademark Office and in other countries. ENERGY STAR is a registered trademark of the Environmental Protection Agency (EPA). Intel, Xeon, and Pentium are registered trademarks and Core is a trademark of Intel Corporation in the U.S. and other countries. HP and COMPAQ are trademarks of Hewlett-Packard Company. Broadcom is a registered trademark and NetXtreme is a trademark of Broadcom Corporation and/or its affiliates in the United States, certain other countries and/or the EU. CommVault Galaxy® or Simpana® are registered trademarks of CommVault Systems, Inc. InfiniBand is a registered trademark and service mark of the InfiniBand Trade Association. Matrox is a registered trademark of Matrox Electronic Systems Ltd. Microsoft and SQL Server are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries. Mellanox is a registered trademark of Mellanox Technologies, Inc. and ConnectX, InfiniBlast, InfiniBridge, InfiniHost, InfiniRISC, InfiniScale, and InfiniPCI are trademarks of Mellanox Technologies, Inc. Red Hat is a registered trademark of Red Hat, Inc. in the United States and other countries. Linux is a registered trademark of Linus Torvalds. Symantec and Backup Exec are trademarks owned by Symantec Corporation or its affiliates in the U.S. and other countries. Novell, SUSE, PlateSpin, and PowerConvert are registered trademarks of Novell, Inc. QLogic and PathScale are registered trademarks of Qlogic Corporation. VMware is a registered trademark and vSphere is a trademark of VMware, Inc. in the United States and/or other jurisdictions. Vizioncore, vRanger, vConverter, and vFoglight are trademarks of Vizioncore Inc. in the United States of America and other countries. Winbond is a registered trademark of Winbond Electronics Corporation. Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Dell disclaims proprietary interest in the marks and names of others.

©Copyright 2010 Dell Inc. All rights reserved. Reproduction or translation of any part of this work beyond that permitted by U.S. copyright laws without the written permission of Dell Inc. is unlawful and strictly forbidden.

Initial Release April 2010

Page 3 of the Dell R210 user manual — Table of contents
Page 3 · click to enlarge
Page 3

Table of contents

1 Product Comparisonp.72 New Technologiesp.112.1 Overviewp.112.2 Detailed Informationp.112.2.1 System Managementp.112.2.2 Software RAIDp.112.2.3 eSATAp.133 System Overviewp.144 Mechanicalp.164.1 Chassis Descriptionp.164.2 Dimensions and Weightp.164.3 Front Panel View and Featuresp.174.4 Back Panel View and Featuresp.184.5 Power Supply Indicatorsp.184.5.1 Power Button LEDp.184.5.2 System Status/ID LEDp.184.6 NIC Indicatorsp.184.7 Side Viewp.194.8 Internal Chassis Viewp.204.9 Railsp.214.10 Fansp.224.11 Control Panel LEDp.224.12 Securityp.224.12.1 Top Cover Lock Mechanismp.224.12.2 Bezelp.224.12.3 Trusted Platform Module (TPM)p.224.12.4 Power Switch Securityp.234.12.5 Intrusion Alertp.234.12.6 Secure Modep.244.13 USB Portsp.244.14 Batteryp.244.15 Field Replaceable Units (FRU)p.254.16 User Accessible Jumpers, Sockets, and Connectorsp.255 Power, Thermal, Acousticp.265.1 Power Suppliesp.265.2 Power Supply Connectors on the Planarp.265.3 Environmental Specificationsp.275.3.1 Temperaturep.275.3.2 Relative Humidityp.275.3.3 Maximum Vibrationp.275.3.4 Maximum Shockp.275.3.5 Altitudep.275.3.6 Airborne Contaminant Levelp.275.4 Power Supply Unit (PSU) Specificationsp.285.5 ENERGY STAR® Compliancep.285.6 Thermalp.285.7 Acousticsp.296 Processorsp.316.1 Overviewp.316.2 Supported Processorsp.316.3 Processor Configurationsp.317 Memoryp.327.1 Overviewp.327.2 DIMMs Supportedp.327.3 Slots/Risersp.337.4 Speedp.337.5 Sparingp.337.6 Mirroringp.337.7 RAIDp.338 Chipsetp.348.1 Overviewp.348.2 Direct Media Interfacep.348.3 PCI Express Interfacep.348.4 SATA Interfacep.348.5 AHCIp.348.6 PCI Interfacep.348.7 Low Pin Count (LPC) Interfacep.358.8 Serial Peripheral Interface (SPI)p.358.9 Compatibility Modulep.358.10 Advanced Programmable Interrupt Controller (APIC)p.358.11 USB Interfacep.358.12 Real-Time Clock (RTC)p.368.13 GPIOp.368.14 Enhanced Power Managementp.368.15 System Management Featuresp.368.15.1 TCO Timerp.368.15.2 Processor Present Indicatorp.368.15.3 Error Code Correction (ECC) Reportingp.368.15.4 Function Disablep.378.16 System Management Bus (SMBus 2.0)p.378.17 Intel Anti-Theft Technologyp.378.18 Intel Virtualization Technology for Directed I/Op.378.19 JTAG Boundary-Scanp.389 BIOSp.399.1 Overviewp.399.2 ACPIp.409.3 Power Management Modesp.409.3.1 Dell Active Power Controllerp.409.3.2 Power Saving BIOS Setting (OS Control)p.419.3.3 Maximum Performancep.4110 I/O Slotsp.4310.1 Overviewp.4310.2 PCI Devicesp.4410.3 Boot Orderp.4710.4 NICsp.4711 Storagep.4811.1 Overviewp.4811.2 Drivesp.4811.3 RAID Configurationsp.4911.4 Optical Disk Drive (ODD)p.4911.5 Tape Drivesp.5012 Video and Audiop.5112.1 Videop.5112.2 Audiop.5113 Rack Informationp.5213.1 Overviewp.5213.2 Railsp.5213.3 Cable Management Arm (CMA)p.5214 Operating Systemsp.5315 Virtualizationp.5516 Systems Managementp.5616.1 Overviewp.5616.2 Server Managementp.5616.3 Embedded Server Managementp.5716.4 Lifecycle Controller and Unified Server Configuratorp.5716.5 iDRAC6 Expressp.5816.6 iDRAC6 Enterprisep.5817 Peripheralsp.6117.1 USBp.6117.2 USB Devicep.6117.3 External Storagep.6218 Packaging Optionsp.63
Page 4 of the Dell R210 user manual
Page 4 · click to enlarge
Page 4

5.7 Acoustics 29 6 Processors 31 6.1 Overview 31 6.2 Supported Processors 31 6.3 Processor Configurations 31 7 Memory 32 7.1 Overview 32 7.2 DIMMs Supported 32 7.3 Slots/Risers 33 7.4 Speed 33 7.5 Sparing 33 7.6 Mirroring 33 7.7 RAID 33 8 Chipset 34 8.1 Overview 34 8.2 Direct Media Interface 34 8.3 PCI Express Interface 34 8.4 SATA Interface 34 8.5 AHCI 34 8.6 PCI Interface 34 8.7 Low Pin Count (LPC) Interface 35 8.8 Serial Peripheral Interface (SPI) 35 8.9 Compatibility Module 35 8.10 Advanced Programmable Interrupt Controller (APIC) 35 8.11 USB Interface 35 8.12 Real-Time Clock (RTC) 36 8.13 GPIO 36 8.14 Enhanced Power Management 36 8.15 System Management Features 36 8.15.1 TCO Timer 36 8.15.2 Processor Present Indicator 36 8.15.3 Error Code Correction (ECC) Reporting 36 8.15.4 Function Disable 37 8.16 System Management Bus (SMBus 2.0) 37 8.17 Intel Anti-Theft Technology 37 8.18 Intel Virtualization Technology for Directed I/O 37 8.19 JTAG Boundary-Scan 38 9 BIOS 39 9.1 Overview 39 9.2 ACPI 40 9.3 Power Management Modes 40 9.3.1 Dell Active Power Controller 40 9.3.2 Power Saving BIOS Setting (OS Control) 41 9.3.3 Maximum Performance 41 10 I/O Slots 43 10.1 Overview 43 10.2 PCI Devices 44 10.3 Boot Order 47 10.4 NICs 47

Page 5 of the Dell R210 user manual — Tables
Page 5 · click to enlarge
Page 5

11 Storage 48 11.1 Overview 48 11.2 Drives 48 11.3 RAID Configurations 49 11.4 Optical Disk Drive (ODD) 49 11.5 Tape Drives 50 12 Video and Audio 51 12.1 Video 51 12.2 Audio 51 13 Rack Information 52 13.1 Overview 52 13.2 Rails 52 13.3 Cable Management Arm (CMA) 52 14 Operating Systems 53 15 Virtualization 55 16 Systems Management 56 16.1 Overview 56 16.2 Server Management 56 16.3 Embedded Server Management 57 16.4 Lifecycle Controller and Unified Server Configurator 57 16.5 iDRAC6 Express 58 16.6 iDRAC6 Enterprise 58 17 Peripherals 61 17.1 USB 61 17.2 USB Device 61 17.3 External Storage 62 18 Packaging Options 62

Tables

Table 1. Comparison of PowerEdge Server Features 8 Table 2. Comparison Overview PERC S100 and S300 12 Table 3. eSATA Modes 13 Table 4. Product Feature Summary 14 Table 5. Overall Dimensions and Weight 16 Table 6. Specific Measurements 16 Table 7. TPM Pin Signals 23 Table 8. Power Supply 24 Pins and Signals 26 Table 9. Power Supply 4 Pins and Signals 26 Table 10. PSU Specifications 28 Table 11. Acoustical Specifications 29 Table 12. Processor Information 31 Table 13. Supported Processor Configurations 32 Table 14. Wake Up Events and States 40 Table 15. Summary of R210 Power Management Features 41 Table 16. Power Profiles that R210 BIOS will Expose in BIOS Setup 42

Page 6 of the Dell R210 user manual — Figures
Page 6 · click to enlarge
Page 6

Table 17. I/O Slot Information 45 Table 18. PCI Card Dimensions 46 Table 19. Bandwidth, Quantities, and Priorities 46 Table 20. Available Drives 48 Table 21. RAID Configurations 49 Table 22. Supported Tape Drives 50 Table 23. PowerEdge R210 Rail Information 52 Table 24. Supported Microsoft Operating Systems 53 Table 25. Supported Linux Operating Systems 54 Table 26. Supported Virtualization OS 55 Table 27. Unified Server Configurator Features and Description 58 Table 28. Features List for BMC, iDRAC6, and vFlash 59 Table 29. USB Controller Priorities 61 Table 30. External Storage 62 Table 31. AMF Single Pack Dimensions and Weights 63 Table 32. EMF Single Pack Dimensions and Weights 63 Table 33. PowerEdge R210 Volatility 66 Table 34. Volatility: Data Writing and Purpose 68 Table 35. Methodology for Data Input to Memory 69 Table 36. Methodology for Memory Protection and Clearing 71

Figures

Figure 1. Server Dimensions 17 Figure 2. Front Panel View 17 Figure 3. Back Panel View 18 Figure 4. Power Button LED 18 Figure 5. Side View 19 Figure 6. Internal Chassis View 20 Figure 7. R210 Static Rails 21 Figure 8. R210 Mounted In Four-Post Square-Hole Rack 21 Figure 9. System Fans 22 Figure 10. Intrusion Switch 23 Figure 11. Internal USB Ports 24 Figure 12. Battery on Motherboard 25 Figure 13. PCIe x16 Riser Card 43 Figure 14. SAS 6/iR Adapter Card Installed 44 Figure 15. Rack Adjustability Range 52 Figure 16. Packaging 64

Page 7 of the Dell R210 user manual — 1 Product Comparison
Page 7 · click to enlarge
Page 7

1 Product Comparison

Dell aims to add value to your business by including the features you need without a lot of the unnecessary extras. Our goal is to deliver value through tailored solutions based on industry standards, as well as purposeful, innovative design of our servers.

The Dell™ PowerEdge™ R210 was developed with a purposeful design, energy-optimized technology, simplified systems management, and the flexibility that make it a great first rack server for the small business or as a specialized application server or edge server for larger corporations. Dell’s entry 1-socket 1U rack server, the PowerEdge R210, offers value, the performance of Intel® Xeon® 3400 series processors, DDR3 memory, eSATA external storage expandability, and enterprise-class manageability in an ultra-compact chassis.

Purposeful Design: The PowerEdge R210 follows the 11th generation PowerEdge portfolio specifications and features the same system design commonality and reliability true to the entire portfolio. All 11th generation PowerEdge servers are built to make the user experience easier. We put all external ports, power supplies, and LED lights in the same location for familiar experience as well as easy installation and deployment.

Robust, metal hard drive carriers and organized cabling are designed to help improve component access and airflow across the server. The PowerEdge R210’s design also provides a LED display positioned on the front of the server for ease of monitoring and troubleshooting condition of the server. It was designed to meet the needs of many IT environments with a short 15.5 inch chassis to allow for flexible deployment almost anywhere, including space- constrained environments.

Energy Efficiency: The PowerEdge R210 incorporates Energy Smart design using a low 250 watt power supply, low-flow fans and logical component layout of the internal components which aids with airflow direction, helping to keep the server cool and reduce noise as much as possible. The result is a server with the smallest power footprint within the 11th generation PowerEdge server portfolio.

Simplified System Management: With the optional advanced embedded systems management capabilities of Lifecycle Controller, Dell brings comprehensive enterprise class manageability into the 1-socket space. Lifecycle Controller is delivered as part of the optional iDRAC Express or iDRAC Enterprise in the PowerEdge R210. The Lifecycle Controller helps to simplify administrator tasks by performing a comprehensive set of provisioning functions such as system deployment, system updates, hardware configuration and diagnostics from a single intuitive interface called Unified Server Configurator (USC) in a pre-OS environment. This helps eliminate the need to use and maintain multiple pieces of disparate CD/DVD media.

Also part of the Dell OpenManage™ portfolio is the Dell Management Console which is included with every Dell server and provides IT administrators with a consolidated console view of their IT infrastructure.

Built with cost-effective RAID options to further protect your valuable data, new eSATA external storage connectivity options, and the latest Intel® Xeon® processor technology, the PowerEdge R210 is an ideal entry 1 socket 1U rack for small businesses and larger offices needing flexibility and manageability in a very small chassis.

Page 8 of the Dell R210 user manual — Table 1. Comparison of PowerEdge Server Features
Page 8 · click to enlarge
Page 8

Table 1. Comparison of PowerEdge Server Features

Feature R210 R200 (Predecessors)

R310 (Next level up)

Processor Quad-core Intel® Xeon® processor 3400 series Dual-core Intel® Celeron® G1101 Dual-core Intel® Pentium® G6950 Dual-core Intel® Core i3 530 Dual-core Intel® Core i3 540 processors

Single Quad-Core Intel® Xeon® 3300 series Single Dual-Core Intel® Xeon® E3100 series Single Quad-Core Intel® Xeon® 3200 series Single Dual-Core Intel® Xeon® 3000 series Single Intel® CoreTM 2 Duo® E4000 series Single Intel® CoreTM 2 Duo® E7000 series Single Intel® Pentium® Dual-Core E2000 series Single Intel® Celeron® E1000 and 400 series

Quad-core Intel® Xeon® processor 3400 series Dual-core Intel® Celeron® G1101 Dual-core Intel® Pentium® G6950 Dual-core Intel® Core i3 530 Dual-core Intel® Core i3 540 processors

Front Side Bus DMI 1333MHz DMI @2.5 Gb/s

# Processors 1 1 1

# Cores Dual or Quad Dual or Quad Dual or Quad

L2/L3 Cache 4MB or 8MB 512K~6M Intel® Xeon®: 8M DT proc: 4, 3 or 2M

Chipset Intel® 3420 chipset Intel® 3210 chipset+ICH9R

Intel® 3420 chipset

DIMMs 4 DDR3 Unbuffered w/ECC 1333/1066 MHz

4 DDR2 Unbuffered w/ECC 800/ 667MHz

6 DDR3 Unbuffered w/ECC or Registered w/ECC 1333/1066MHz

Min/Max RAM 1GB/16GB 512MB/8GB 1GB/32GB

HD Bays 2 x 3.5” or 2 x 2.5” 2 x 3.5” 4 x 3.5” Optional Hot-Swap Support 2.5" HDDs via Hot-Swap tray

HD Types Default SATA. Optional SAS and SSD via add-in controller

Default SATA. Optional SAS via add- in controller

Default SATA. Optional SAS and SSD via add-in controller

Ext Drive Bay(s) 1 for slim ODD 1 for slim ODD 1 for slim ODD

Page 9 of the Dell R210 user manual — 1 Product Comparison
Page 9 · click to enlarge
Page 9

Feature R210 R200 (Predecessors)

R310 (Next level up)

Chipset based SATA Chipset based SATA Chipset based SATA

NON-RAID: SAS 5/E LSI 2032 (For TBU only) RAID: SAS 6/iR Adapter PERC S100 PERC S300 PERC H200 PERC 6/E PERC H800

NON-RAIDSAS 5/E LSI 2032 (For TBU only) RAID: SAS 6/iR Adapter PERC 6/E

NON-RAID: SAS HBA LSI 2032 (For TBU only), PERC H800 RAID: SAS 6/iR Modular PERC H200 (6Gb/s) PERC H700 (6Gb/s) with 512MB PERC H700 (6Gb/s) NV DRAM with 512MB or 1G PERC S100 (software based) PERC S300 Modular (software based)

Availability ECC Memory, ADD-in RAID, TPM/CTPM

ECC memory, Add-in RAID, toolless chassis

Hot-swap HDD; Redundant PSU; Quad-pack LED diagnostic/LCD with Hot-swap HDD chassis ;ECC Memory

Server Mgt. BMC, IPMI 2.0 compliant; Full Dell™ OpenManage™ suite Optional; iDRAC6 Express, iDRAC6 Enterprise, vFlash

DRAC4 Full Dell™ OpenManage™ suite

BMC, IPMI 2.0 compliant; Full Dell™ OpenManage™ suite Optional; iDRAC6 Express, iDRAC6 Enterprise, vFlash

I/O Slots 1 x PCIe x16 (True x16, Gen2); full height, half length Support x16 bandwidth card under 25W

Riser 1: One PCIex 8, one PCIe x4 (w/ x8 connector) Riser 2: One PCI-X 64/133 and one PCIe x8

Riser 1: PCIe x16 (x8 routing), Full Height/ Half Length, Gen 2 Riser 2: PCIe x8 (x8 routing), Full Height / Half Length, Gen 2 2 PCIe G2 slots: Slot 1: PCIe x16 (x8

Embedded HD Controller · Optional Storage Controller

Page 10 of the Dell R210 user manual — 1 Product Comparison
Page 10 · click to enlarge
Page 10
Dell R210 — 1 Product Comparison diagram (page 10)
Fig. 3 · 1 Product Comparison

NIC/LOM 2x GbE LOM w/o TOE Optional: various NIC available

Power Supplies Non-redundant, 250W (80+ Bronze) Auto Ranging (100V~240V)

Non-redundant, 350W (80+ Bronze) Optional redundant, 400W (80+ Silver) Auto Ranging (100V~240V)

Dimensions (HxWxD) 42.6 x 431 x 393.7 (mm) (w/o ear and bezel) 1.67” x 17.1” x 15.5”

42.67 x 447.0 x 546.1 (mm) (w/o ear and bezel) 1.68” x 17.6” x 21.5”

42.4 x 434.0 x 610 (mm) ( w/o bezel) 1.67” x 17.10” x 24.00”

Page 11 of the Dell R210 user manual — 2.2.2 Software RAID
Page 11 · click to enlarge
Page 11

2 New Technologies

2.1 Overview

A number of new technologies are used in the PowerEdge R210, including:

  • iDRAC6 (new Dell server remote management controller)
  • Software RAID PERC S100 and PERC S300
  • E-SATA connector

2.2 Detailed Information

2.2.1 System Management

The PowerEdge R210 supports iDRAC6 Express and Enterprise for advanced manageability. For more information on iDRAC 6 options, please see Section 16, Systems Management.

2.2.2 Software RAID

Dell PowerEdge RAID controller portfolio now offers Enterprise Software RAID in the PERC S100 and PERC S300 options. PERC S100 and S300 are supported in PowerEdge 11th generation value-based servers. Software RAID code uses the CPU of the computer system to execute the RAID tasks including leveraging the CPUs (calculating power as well as sharing memory), internal bus resources, operating system, and all associated applications. Software-based RAID uses drives which are attached to the computer system via a built-in I/O interface or a processor-less host bus adapter (HBA). The RAID function becomes active as soon as the operating system has loaded the RAID driver software. Previous generations of PERC controllers have been based on Hardware RAID technology, the PERC S100 and PERC S300 are based on Software RAID technology. The software based RAID options provide a cost effective entry-level RAID. Both the PERCS100 and S300 versions offer similar RAID level support, including RAID 0, 1, 5, 10. In the case of the PERC S100, it offers a minimal RAID option where the I/O Controller Hub (ICH) chipset of the motherboard enables a SATA RAID option. There is no new hardware involved. The PERC S100 controller solution supports up to 4 cabled SATA Hard Disk Drives (HDD) or Solid State Disk (SSD) drives and is ideal for SMB usage scenarios. For the PERC S300, the hardware component of the controller is based on the Dell SAS HBA (leveraging SAS 6/iR) and allows for both SAS and SATA connectivity. PERC S300 controller solution supports up to 8 cabled or hot plug SAS/SATA Hard Disk Drives (HDDs).

Page 12 of the Dell R210 user manual — Table 2. Comparison Overview PERC S100 and S300
Page 12 · click to enlarge
Page 12

Table 2. Comparison Overview PERC S100 and S300

Interface 3Gb SATA (SATA II)

3Gb SAS/SATA (SAS 1.1)

I/O Controller Intel® ICH10R Dell 3Gb/s SAS Adapter (2 internal connectors with x4 SAS ports)

Cache Memory N/A N/A

Battery-backed cache No No

Max Number of Physical Drives

HDD Support SATA (Cabled)

SAS & SATA (Cabled or hot plug)

SSD Support SATA (Cabled)

SED Support Not Supported Not Supported

RAID Levels 0, 1, 5, 10 0, 1, 5, 10

Non-RAID Volumes Yes Yes

Max Number of Virtual Disks per Controller

Operating System Support (Windows Server Only)

Microsoft® Windows Server® 2003 R2 SP2, 32/64-bit, Standard & Enterprise Editions* Microsoft® Windows Server® 2003 R2 SP2 32-bit Web Edition Microsoft® Windows Server® 2008 SP2, 32/64-bit, Standard & Enterprise Editions Microsoft® Windows Server® 2008 R2, 64-bit, Web, Standard, and Enterprise Editions

Microsoft® Windows Server® 2003 R2 SP2, 32/64-bit, Standard & Enterprise Editions* Microsoft® Windows Server® 2003 R2 SP2 32-bit Web Edition Microsoft® Windows Server® 2008 SP2, 32/64-bit, Standard & Enterprise Editions Microsoft® Windows Server® 2008 R2, 64-bit, Web, Standard, and Enterprise Editions

Not Supported Not Supported

Storage Management OpenManage™ 6.2 or later OpenManage 6.2™ or later

Show 7 more labels / short text on this page
Feature/Spec S100 S300 · System Communication · Integrated PCIe Lanes · Not Supported · Global Hotspare Support · Yes Yes · Virtualization Support
Page 13 of the Dell R210 user manual — Table 3. eSATA Modes
Page 13 · click to enlarge
Page 13

up-to-date information, see the Operating System Support Matrix for Dell PowerEdge Systems on Dell.com.

2.2.3 eSATA

External Serial Advanced Technology Attachment (eSATA) serves as an external interface for SATA technologies. For customers who want fast (up to 1.5Gbit/s), easy- to-use external storage that has advanced features such as S.M.A.R.T. (Self- Monitoring, Analysis, and Reporting Technology) protection, eSATA may be a good choice.

eSATA devices are not bootable when BIOS is set to RAID mode and are not supported as a part of Virtual Disks when in RAID mode for S100.

To operate eSATA devices in the Red Hat® Enterprise Linux® 4.8 environment, the BIOS mode must be manually switched from default (AHCI mode) to ATA mode.

Table 3. eSATA Modes

Mode Bootable Hot-Pluggable Restrictions

ATA mode Yes No

AHCI mode Yes Yes RHEL 4.8 is not supported.

RAID mode (S100 enabled)

No No Linux and Virtualization OS are not supported

Page 14 of the Dell R210 user manual — 4TB
Page 14 · click to enlarge
Page 14

3 System Overview

Table 4. Product Feature Summary

Processors Quad-core Intel® Xeon® 3400 series processors Dual-core Intel® Celeron® G1101 Dual-core Intel® Pentium® G6950 Dual-core Intel® Core™ i3 530 Dual-core Intel® Core™ i3 540 processors

Front Side Bus or HyperTransport

DMI (Direct Media Interface)

Chipset Intel® 3420 chipset

Memory Up to 16GB (4 U-DIMMs): 1GB/2GB/4GB DDR3 1066MHz or 1333MHz

I/O Slots 1 PCIe x16 G2 slot

RAID Controllers Internal Controllers: SAS 6/iR PERC S100 (software-based) PERC S300 (software-based) PERC H200 External Controllers: PERC 6/E with 256MB or 512MB of battery-backed cache SAS 5/E PERC H800 LSI2032 PCIe SCSI HBA

Drive Bays Cabled options availableUp to two 2.5”/ 3.5” SAS, SATA or SSD drives

4TB

Hard Drives 3.5 inch SATA (7.2K rpm): 160GB, 250GB, 500GB, 1TB, 2TB 3.5 inch Near-line SAS (7.2 rpm): 1TB, 2TB 3.5 inch SAS (10K rpm): 600GB 3.5 inch SAS (15K rpm): 146GB, 300GB, 450GB, 600GB 2.5 inch SAS (10K rpm): 146GB, 300GB

1 Broadcom® NetXtreme™ 5709 with Dual Port Gigabit Ethernet NIC, Copper, w/TOE PCIe x4 Broadcom® NetXtreme™ 5709 Dual Port Gigabit Ethernet NIC, Copper, TOE/ISCI PCIe x4

Show 6 more labels / short text on this page
Feature Product Description · Form Factor Rack · Processor Sockets 1 · Cache 8MB · Maximum Internal Storage · Network Interface Cards
Page 15 of the Dell R210 user manual — 3 System Overview
Page 15 · click to enlarge
Page 15

Intel® PRO/ 1000PT Single Port Adapter, Gigabit Ethernet NIC, PCIe x1 Intel® Gigabit ET Dual Port Adapter, Gigabit Ethernet NIC, PCIe x4 Intel® Gigabit ET Quad Port Adapter, Gigabit Ethernet NIC, PCIe x4

Power Supply Single-cabled power supply (250W)

Availability Quad-pack LED diagnostics, ECC Memory, add-in RAID, TPM/C- TPM

Video Matrox® G200eW w/ 8MB memory

Remote Management iDRAC6 optional

Systems Management BMC, IPMI 2.0 compliant Dell™ OpenManage™ featuring Dell Management Console Unified Server Configurator Lifecycle Controller enabled via optional: iDRAC6 Express, iDRAC6 Enterprise and vFlash

Rack Support Support for Static ReadyRails™ 4-post and 2-post racks

Operating Systems Microsoft® Factory Installed OS Options: Microsoft® Windows® Small Business Server 2008, 64-bit Standard and Premium Edition Microsoft® Windows Server® 2003 R2 with SP2 32-bit Standard and Enterprise Edition Microsoft® Windows Server® 2003 R2 with SP2 64-bit, Standard and Enterprise Editions Microsoft® Windows Server® 2008 32-bit, Web, Standard and Enterprise Edition Microsoft® Windows Server® 2008 64-bit, Web, Standard and Enterprise Editions Microsoft® Windows Server® 2008 SP2 32-bit, Web, Standard and Enterprise Edition Microsoft® Windows Server® 2008 SP2 64-bit, Web, Standard and Enterprise Edition Microsoft® Windows Server® 2008 R2 64-bit Web, Standard and Enterprise Edition Microsoft® Windows Server® 2008 Foundation Microsoft® Windows Server® 2008 Foundation R2 Microsoft® Non- Factory Installed OS Option: Microsoft® Windows® Essential Business Server 2008 64-bit Standard and Premium Edition Factory Installed Linux OS Options: Novell® SUSE® Linux® Enterprise Server 11 Red Hat® Enterprise Linux® 5.3 Virtualization OS Option: Microsoft® Windows Server® 2008, with Hyper-V™

Feature Product Description

Page 16 of the Dell R210 user manual — Table 6. Specific Measurements
Page 16 · click to enlarge
Page 16

4 Mechanical

4.1 Chassis Description

The PowerEdge R210 is a 1-socket 1U server. The configuration details are as follows:

  • HDD Type : 2x 3.5” Cabled HDD or 2 x 2.5” cabled HDD
  • PSU Type: Single Non-Redundant PSU
  • Diagnostic: LED

4.2 Dimensions and Weight

Table 5. Overall Dimensions and Weight

Dell R210 — Table 5. Overall Dimensions and Weight diagram (page 16)
Fig. 4 · Table 5. Overall Dimensions and Weight

1.68” x 17” x 15.5” (42.6 x 431 x 393.7 mm)

Measurements in Table 6 correspond to the diagram shown in Figure 1 below.

Table 6. Specific Measurements

Dell R210 — Table 6. Specific Measurements diagram (page 16)
Fig. 5 · Table 6. Specific Measurements

434.0 482.58 42.4 N/A N/A 31.35 NA 393.7 397.49 5.95

Page 17 of the Dell R210 user manual — Figure 2. Front Panel View
Page 17 · click to enlarge
Page 17
Dell R210 — 4.3 Front Panel View and Features diagram (page 17)
Fig. 6 · 4.3 Front Panel View and Features

Figure 1. Server Dimensions

* Zb goes to the nominal rear wall external surface where the motherboard I/O connectors reside.

4.3 Front Panel View and Features

Dell R210 — 4.3 Front Panel View and Features diagram (page 17)
Fig. 7 · 4.3 Front Panel View and Features

Figure 2. Front Panel View

Page 18 of the Dell R210 user manual — 4.6 NIC Indicators
Page 18 · click to enlarge
Page 18

4.4 Back Panel View and Features

Dell R210 — 4.4 Back Panel View and Features diagram (page 18)
Fig. 8 · 4.4 Back Panel View and Features

Figure 3. Back Panel View

4.5 Power Supply Indicators

4.5.1 Power Button LED

The Power button controls the system's power, turning the unit on and off.

All PowerEdge servers have the Power LED light-pipe integrated in the Power button. The color of the power LED is green. The lighting pattern must be in the form of a standard Power icon.

Dell R210 — Figure 3. Back Panel View diagram (page 18)
Fig. 9 · Figure 3. Back Panel View

Figure 4. Power Button LED

4.5.2 System Status/ID LED

The System Status/ID LED, present on non-modular rack-dense and rackable tower PowerEdge servers, has the following states:

  • No light —System is in the off state (S5, or mechanical (no AC power)
  • Blinking Amber —System fault/error condition.
  • Steady Blue —Normal operating state (S0)
  • Blinking Blue —System ID engaged

This LED remains powered during non-operational (standby, shutdown) modes to enable system identification.

4.6 NIC Indicators

See the Hardware Owner’s Manual for information.

Page 19 of the Dell R210 user manual — Figure 5. Side View
Page 19 · click to enlarge
Page 19

4.7 Side View

Dell R210 — 4.7 Side View diagram (page 19)
Fig. 10 · 4.7 Side View

Figure 5. Side View

Page 20 of the Dell R210 user manual — Figure 6. Internal Chassis View
Page 20 · click to enlarge
Page 20

4.8 Internal Chassis View

Dell R210 — 4.8 Internal Chassis View diagram (page 20)
Fig. 11 · 4.8 Internal Chassis View

Figure 6. Internal Chassis View

Page 21 of the Dell R210 user manual — Figure 8. R210 Mounted In Four-Post Square-Hole Rack
Page 21 · click to enlarge
Page 21

4.9 Rails

ReadyRails™ static rails for tool-less mounting in 4-post racks with square or unthreaded round holes or tooled mounting in 4-post threaded and 2-post racks

The R210 rails must first be attached to the sides of the system and then inserted into the cabinet members installed in the rack. For additional information regarding rail options for the R210, see Section 13.

Dell R210 — 4.9 Rails diagram (page 21)
Fig. 12 · 4.9 Rails

Figure 7. R210 Static Rails

Dell R210 — Figure 7. R210 Static Rails diagram (page 21)
Fig. 13 · Figure 7. R210 Static Rails

Figure 8. R210 Mounted In Four-Post Square-Hole Rack

Page 22 of the Dell R210 user manual — 4.12.3 Trusted Platform Module (TPM)
Page 22 · click to enlarge
Page 22

4.10 Fans

There are three system fans located in the middle of the system.

Dell R210 — 4.10 Fans diagram (page 22)
Fig. 14 · 4.10 Fans

Figure 9. System Fans

4.11 Control Panel LED

See the Hardware Owner’s Manual for information.

4.12 Security

4.12.1 Top Cover Lock Mechanism

The PowerEdge R210 uses a coin lock on the top cover. This lock must be unlocked and the cover removed to access the internal components.

4.12.2 Bezel

The bezel lock is located on the front of the bezel and provides security for the system by preventing access to optical disk drives and the Power button.

4.12.3 Trusted Platform Module (TPM)

The PowerEdge R210 uses a TPM 1.2 compliant encryption chip solution on the system board with BIOS support worldwide, except for China where Trusted Computing Module (TCM) is the standard. TPM is disabled by default.

Page 23 of the Dell R210 user manual — Figure 10. Intrusion Switch
Page 23 · click to enlarge
Page 23

Table 7. TPM Pin Signals

Dell R210 — Table 7. TPM Pin Signals diagram (page 23)
Fig. 15 · Table 7. TPM Pin Signals

4.12.4 Power Switch Security

The LED control panel is designed so the power switch cannot be accidentally turned on or off. In addition, in BIOS there is an optional setting in the CMOS setup to disable the power switch.

4.12.5 Intrusion Alert

The intrusion switch snaps into the chassis located under the side cover. The intrusion switch detects and alerts the user that the side cover is open.

Dell R210 — 4.12.5 Intrusion Alert diagram (page 23)
Fig. 16 · 4.12.5 Intrusion Alert

Figure 10. Intrusion Switch

Page 24 of the Dell R210 user manual — Figure 11. Internal USB Ports
Page 24 · click to enlarge
Page 24

4.12.6 Secure Mode

BIOS has the ability to enter a secure boot mode via setup. This mode includes the option to lock out the power and NMI switches on the control panel or set up a system password. See the BIOS specification in the Hardware Owner’s Manual for information.

4.13 USB Ports

The PowerEdge R210 has two internal USB ports.

Dell R210 — 4.13 USB Ports diagram (page 24)
Fig. 17 · 4.13 USB Ports

Figure 11. Internal USB Ports

4.14 Battery

A replaceable lithium battery (CR2032) is mounted on the motherboard to provide backup power for the real-time clock and CMOS RAM in the Platform Controller Hub (PCH).

Page 25 of the Dell R210 user manual — 4.16 User Accessible Jumpers, Sockets, and Connectors
Page 25 · click to enlarge
Page 25
Dell R210 — 4.15 Field Replaceable Units (FRU) diagram (page 25)
Fig. 18 · 4.15 Field Replaceable Units (FRU)

Figure 12. Battery on Motherboard

4.15 Field Replaceable Units (FRU)

The planar contains a 16K x 8 serial EEPROM to store FRU information including Dell part number, part revision level, and serial number. This information is used by the SEL (system event log) and the BMC (baseboard management controller).

Parts available for field replacement include:

  • CMOS battery
  • Expansion card
  • Front bezel
  • HDD
  • I/O panel
  • Memory
  • ODD
  • Power supply
  • Processor
  • Processor shroud
  • System board
  • System fan

4.16 User Accessible Jumpers, Sockets, and Connectors

See the Hardware Owner’s Manual.

Page 26 of the Dell R210 user manual — Table 9. Power Supply 4 Pins and Signals
Page 26 · click to enlarge
Page 26

5 Power, Thermal, Acoustic

5.1 Power Supplies

The base system includes a single 250W power supply. This unit provides power to the planar and the two internal hard drive bays. Power will be “soft-switched” allowing power cycling using a switch on the front of the system enclosure or through software control (server management functions). The power system is compatible with industry standards, such as ACPI and Server 2000.

Standard VRD (Voltage Regulator Down) modules that conform to VRD11.1 specification are used. This reduces the board layout complexity while offering design modularity. As processor speeds increase, a newer VRD can be used to accommodate the power increase with no need to re-spin the board. The VRD is integrated onto the planar and is not field upgradeable.

5.2 Power Supply Connectors on the Planar

There are 2 separate power supply connectors on the planar. One connector is an ATX connector (2x12) and the other one is a 2x2 connector to provide an additional two pins for +12V. The connector Pin definition (2 x 12 power connector) is not ATX standard.

The 2x12 connector provides 3.3V, 5V, 12V, and 12V standby to the system. (3.3V standby to system is generated from 12V standby).

Table 8. Power Supply 24 Pins and Signals

Dell R210 — Table 8. Power Supply 24 Pins and Signals diagram (page 26)
Fig. 19 · Table 8. Power Supply 24 Pins and Signals

Table 9. Power Supply 4 Pins and Signals

Dell R210 — Table 9. Power Supply 4 Pins and Signals diagram (page 26)
Fig. 20 · Table 9. Power Supply 4 Pins and Signals
Page 27 of the Dell R210 user manual — 5.3.6 Airborne Contaminant Level
Page 27 · click to enlarge
Page 27

5.3 Environmental Specifications

5.3.1 Temperature

Operating: 10° to 35°C (50° to 95°F) with a maximum temperature gradation of 10°C per hour (NOTE: For altitudes above 2950 feet, the maximum operating temperature is de-rated 1ºF/550 ft.)

Storage: –40° to 65°C (–40° to 149°F) with a maximum temperature gradation of 20°C per hour

5.3.2 Relative Humidity

Operating20% to 80% (non-condensing) with a maximum humidity gradation of 10% per hour
Storage5% to 95% (non-condensing)

5.3.3 Maximum Vibration

Operating0.26 Grms at 5–350 Hz for 15 min
Storage1.54 Grms at 10–250 Hz for 15 min

5.3.4 Maximum Shock

Operating: One shock pulse in the positive z axis (one pulse on each side of the system) of 31 G for 2.6 ms in the operational orientation

Storage: Six consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 71 G for up to 2 ms

Six consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 32 G faired square wave pulse with velocity change at 270 inches/second (686 centimeters/second)

5.3.5 Altitude

Operating: 16 to 3048 m (–50 to 10,000 ft) (Note: For altitudes above 2950 feet, the maximum operating temperature is de-rated 1ºF/550 ft.)

Storage16 to 10,600 m (–50 to 35,000 ft)

5.3.6 Airborne Contaminant Level

ClassG2 or lower as defined by ISA-S71.04-1985
Page 28 of the Dell R210 user manual — 5.6 Thermal
Page 28 · click to enlarge
Page 28

5.4 Power Supply Unit (PSU) Specifications

Table 10. PSU Specifications

Dell R210 — Table 10. PSU Specifications diagram (page 28)
Fig. 21 · Table 10. PSU Specifications

Dimensions L-2101 mm x W-106 mm x H-40.0 mm

AC Cord Rating 15 Amps @ 120 VAC, 10 Amps @ 240 VAC

Under typical line conditions and over the entire system ambient operating range, the inrush current may reach 25 Amps for 10 ms or less.

Efficiency 20% to 100% Load 82–85% @115 VAC 82–85% @ 230 VAC

1 Does not include the power supply handle or ejection tab

5.5 ENERGY STAR ® Compliance

See the ENERGY STAR Compliance results on Dell.com.

5.6 Thermal

The thermal design of the PowerEdge R210 reflects the following:

  • Closed loop thermal control algorithm. Closed loop thermal control method uses feedback temperatures to dynamically determine proper fan speeds.
  • Comprehensive thermal management. The PowerEdge R210 controls system cooling fan speed based on several different responses from critical components’ sensors, such as CPU temperature, DIMM temperature, inlet ambient temperature, and system configurations. The thermal management adjusts proper cooling ability for the system according to what the system really needs.
Page 29 of the Dell R210 user manual — Definitions
Page 29 · click to enlarge
Page 29
  • Optimized Ventilation. R210 chassis has a custom ventilation design for optimized air flow path. Each component and peripheral is ensured sufficient air to cool.
  • Power-to-Cool. Dell continues to improve the design and cooling efficiency for server products. The power-to-cool ratio of the PowerEdge R210 is improved over that of its predecessor, PowerEdge R200.

5.7 Acoustics

The acoustical design of the PowerEdge R210 reflects the following:

  • Adherence to Dell’s high sound quality standards. Sound quality is different from sound power level and sound pressure level in that it describes how humans respond to annoyances in sound, like whistles, hums, etc. One of the sound quality metrics in the Dell specification is prominence ratio of a tone, as listed in the table below.
  • Noise ramp and descent at bootup. Fan speeds, hence noise levels, ramp during the boot process in order to add a layer of protection for component cooling in case the system were not to boot properly.
  • Noise levels vs. configurations. The noise level of PowerEdge R210 is not dependent upon the hardware configuration of the system. The table below shows the noise levels of the PowerEdge R210 with maximum configuration.

Table 11. Acoustical Specifications

Dell R210 — Table 11. Acoustical Specifications diagram (page 29)
Fig. 22 · Table 11. Acoustical Specifications

Definitions

Standby: AC Power is connected to Power Supply Units but system is not turned on.

Idle: Reference ISO7779 (1999) definition 3.1.7; system is running in its OS but no other specific activity.

Stressed Processor: An operating mode per ISO7779 (1999) definition 3.1.6. The software MemBW4 is activated to stress the processors.

LwA–UL: The upper limit sound power level (LwA) calculated per section 4.4.2 of ISO 9296 (1988) and measured in accordance to ISO 7779 (1999).

LpA: A-Weighted sound pressure level. The system is placed in a rack with its bottom at 75 cm from the floor. The acoustic transducer is at front bystander position, ref ISO7779 (1999) Section 8.6.2.

Prominent tone: Criteria of D.5 and D.8 of ECMA-74 9th ed. (2005) are followed to determine if discrete tones are prominent. The system is placed in a rack with its

Page 30 of the Dell R210 user manual — 5.7 Acoustics
Page 30 · click to enlarge
Page 30

bottom at 75 cm from the floor. The acoustic transducer is at front bystander position, ref ISO7779 (1999) Section 8.6.2.

Page 31 of the Dell R210 user manual — 6.3 Processor Configurations
Page 31 · click to enlarge
Page 31

6 Processors

6.1 Overview

The PowerEdge R210 is a 1S, entry-level server based on the Intel FCLGA1156 to support Intel Xeon 3400 series and Core i3 processors.

6.2 Supported Processors

Table 12. Processor Information

Dell R210 — Table 12. Processor Information diagram (page 31)
Fig. 23 · Table 12. Processor Information

6.3 Processor Configurations

The PowerEdge R210 is a single socket 1U rack server that operates in single processor mode only. The memory controller is embedded in the processor.

Page 32 of the Dell R210 user manual — Table 13. Supported Processor Configurations
Page 32 · click to enlarge
Page 32

7 Memory

7.1 Overview

Features of the PowerEdge R210 memory include:

  • 2 channels per processor
  • Support for Unbuffered ECC DDDR3 DIMMs.
  • Support for DDR3 speeds of 1066/1333
  • 4 DIMM sockets (16GB Maximum capacity)
  • Support for Single Rank and Dual Rank DIMMs

7.2 DIMMs Supported

The following DIMMs are supported by the PowerEdge R210:

  • 1GB, DDR3 UDIMM, 1066 w/ECC
  • 1GB, DDR3 UDIMM, 1333 w/ECC
  • 2GB, DDR3 UDIMM, 1066 w/ECC
  • 2GB, DDR3 UDIMM, 1333 w/ECC
  • 4GB, DDR3 UDIMM, 1066 w/ECC
  • 4GB, DDR3 UDIMM, 1333 w/ECC

Table 13. Supported Processor Configurations

Dell R210 — Table 13. Supported Processor Configurations diagram (page 32)
Fig. 24 · Table 13. Supported Processor Configurations

1GB 1066 1066 UDIMM 1 X8

1GB 1333 1333 UDIMM 1 X8

2GB 1066 1066 UDIMM 1 2 1,2 1 X8

2GB 1333 1333 UDIMM 1 2 1,2 1 X8

4GB 1066 1066 UDIMM 1 4 1,2,3,4 1 X8

4GB 1066 1066 UDIMM 2 2 1,2 2 X8

4GB 1333 1333 UDIMM 1 4 1,2,3,4 1 X8

4GB 1333 1333 UDIMM 2 2 1,2 2 X8

8GB 1066 1066 UDIMM 2 4 1,2,3,4 2 X8

8GB 1066 1066 UDIMM 4 2 1,2 2 X8

8GB 1333 1333 UDIMM 2 4 1,2,3,4 2 X8

8GB 1333 1333 UDIMM 4 2 1,2 2 X8

16GB 1066 1066 UDIMM 4 4 1,2,3,4 2 X8

Page 33 of the Dell R210 user manual — 7.7 RAID
Page 33 · click to enlarge
Page 33
Dell R210 — 7.3 Slots/Risers diagram (page 33)
Fig. 25 · 7.3 Slots/Risers

16GB 1333 1333 UDIMM 4 4 1,2,3,4 2 X8

2GB 1066 1066 UDIMM 2 1 1 2 X8

2GB 1333 1333 UDIMM 2 1 1 2 X8

4GB 1066 1066 UDIMM 4 1 1 2 X8

4GB 1333 1333 UDIMM 4 1 1 2 X8

7.3 Slots/Risers

The PowerEdge R210 planar provides four 72-bit (240-pin) sockets for DIMM memory modules. These modules are DDR3-800/1066/1333 Unbuffered DDR SDRAM DIMMs. The modules are configured as 72 bits wide to provide for ECC. The memory controller in the CPU performs the ECC. The system supports a minimum of 1GB upgradeable to 16 of RAM, using the following DIMM sizes:

  • 1GB, DIMM Module
  • 2GB, DIMM Module
  • 4GB, DIMM Module

7.4 Speed

The PowerEdge R210 supports 1066/1333MHz DDR3 memory.

7.5 Sparing

Not supported.

7.6 Mirroring

Not supported.

7.7 RAID

Memory RAID is not supported.

Page 34 of the Dell R210 user manual — 8.6 PCI Interface
Page 34 · click to enlarge
Page 34

8 Chipset

8.1 Overview

The PowerEdge R210 planar incorporates the Intel Ibex Peak as PCH chipset. The Ibex Peak is a highly integrated I/O controller. The high-level features supported by the chipset and implemented on the PowerEdge R210 are detailed in the sections that follow.

8.2 Direct Media Interface

Direct Media Interface (DMI) is the chip-to-chip connection between the processor and Ibex Peak chipset. This high-speed interface integrates advanced priority-based servicing allowing for concurrent traffic and true isochronous transfer capabilities. Base functionality is completely software-transparent, permitting current and legacy software to operate normally.

8.3 PCI Express Interface

The Ibex Peak provides up to 8 PCI Express Root Ports, supporting the PCI Express Base Specification, Revision 2.0. Each Root Port supports 2.5 GB/s bandwidth in each direction (5 GB/s concurrent). PCI Express Root Ports 1-4 can be statically configured as four x1 Ports or ganged together to form one x 4 ports. Ports 5 and 6 can only be used as two x 1 port.

8.4 SATA Interface

The Ibex Peak has two integrated SATA host controllers that support independent DMA operation on up to six ports and supports data transfer rates of up to 3.0 GB/s (300MB/s). The SATA controller contains two modes of operation – a legacy mode using I/O space, and an AHCI mode using memory space. Software that uses legacy mode will not have AHCI capabilities.

The Ibex Peak supports the Serial ATA Specification, Revision 1.0a. The Ibex Peak also supports several optional sections of the Serial ATA II: Extensions to Serial ATA 1.0 Specification, Revision 1.0 (AHCI support is required for some elements).

8.5 AHCI

The Ibex Peak provides hardware support for Advanced Host Controller Interface (AHCI), a new programming interface for SATA host controllers. Platforms supporting AHCI may take advantage of performance features such as no master/slave designation for SATA devices—each device is treated as a master—and hardware-assisted native command queuing. AHCI also provides usability enhancements such as Hot-Plug. AHCI requires appropriate software support (e.g., an AHCI driver) and for some features, hardware support in the SATA device or additional platform hardware.

8.6 PCI Interface

The Ibex Peak PCI interface provides a 33 MHz, Revision 2.3 implementation. The Ibex Peak integrates a PCI arbiter that supports up to four external PCI bus masters in addition to the internal Ibex Peak requests. This allows for combinations of up to four PCI down devices and PCI slots.

Page 35 of the Dell R210 user manual — 8.11 USB Interface
Page 35 · click to enlarge
Page 35

8.7 Low Pin Count (LPC) Interface

The Ibex Peak implements an LPC Interface as described in the LPC 1.1 Specification. The Low Pin Count (LPC) bridge function of the Ibex Peak resides in PCI Device 31:Function 0. In addition to the LPC bridge interface function, D31:F0 contains other functional units including DMA, interrupt controllers, timers, power management, system management, GPIO, and RTC.

8.8 Serial Peripheral Interface (SPI)

The Ibex Peak implements an SPI Interface as an alternative interface for the BIOS flash device. An SPI flash device can be used as a replacement for the FWH, and is required to support Gigabit Ethernet, Intel® Active Management Technology and integrated Intel Quiet System Technology. The Ibex Peak supports up to two SPI flash devices with speed up to 20 MHz, 33 MHz utilizing two chip select pins.

8.9 Compatibility Module

The DMA controller incorporates the logic of two 82C37 DMA controllers, with seven independently programmable channels. Channels 0–3 are hardwired to 8-bit, count-by-byte transfers, and channels 5–7 are hardwired to 16-bit, count-by-word transfers. Any two of the seven DMA channels can be programmed to support fast Type-F transfers.

Channel 4 is reserved as a generic bus master request.

The Ibex Peak supports LPC DMA, which is similar to ISA DMA, through the Ibex Peak’s DMA controller. LPC DMA is handled through the use of the LDRQ# lines from peripherals and special encoding on LAD[3:0] from the host. Single, Demand, Verify, and Increment modes are supported on the LPC interface.

The timer/counter block contains three counters that are equivalent in function to those found in one 82C54 programmable interval timer. These three counters are combined to provide the system timer function, and speaker tone. The 14.31818 MHz oscillator input provides the clock source for these three counters.

The Ibex Peak provides an ISA-Compatible Programmable Interrupt Controller (PIC) that incorporates the functionality of two, 82C59 interrupt controllers. The two interrupt controllers are cascaded so that 14 external and two internal interrupts are possible. In addition, the Ibex Peak supports a serial interrupt scheme.

All of the registers in these modules can be read and restored. This is required to save and restore system state after power has been removed and restored to the platform.

8.10 Advanced Programmable Interrupt Controller (APIC)

In addition to the standard ISA compatible Programmable Interrupt controller (PIC) described in the previous section, the Ibex Peak incorporates the Advanced Programmable Interrupt Controller (APIC).

8.11 USB Interface

The Ibex Peak contains up to two Enhanced Host Controller Interface (EHCI) host controllers that support USB high-speed signaling. High-speed USB 2.0 allows data transfers up to 480 Mb/s which is 40 times faster than full-speed USB. The Ibex Peak also contains up to seven Universal Host Controller Interface (UHCI) controllers that support USB full-speed and low-speed signaling.

The Ibex Peak supports up to fourteen USB 2.0 ports. All fourteen ports are high-speed, full- speed, and low-speed capable. Ibex Peak’s port-routing logic determines whether a USB port is controlled by one of the UHCI or EHCI controllers.

Page 36 of the Dell R210 user manual — 8.15.3 Error Code Correction (ECC) Reporting
Page 36 · click to enlarge
Page 36

8.12 Real-Time Clock (RTC)

The Ibex Peak contains a real-time clock with 256 bytes of battery-backed RAM.

The real-time clock performs two key functions: keeping track of the time of day and storing system data, even when the system is powered down. The RTC operates on a 32.768 KHz crystal and a 3 V battery.

The RTC also supports two lockable memory ranges. By setting bits in the configuration space, two 8-byte ranges can be locked to read and write accesses. This prevents unauthorized reading of passwords or other system security information.

The RTC also supports a date alarm that allows for scheduling a wake up event up to 30 days in advance, rather than just 24 hours in advance.

8.13 GPIO

Various general purpose inputs and outputs are provided for custom system design. The number of inputs and outputs varies depending on Ibex Peak configuration.

8.14 Enhanced Power Management

The Ibex Peak’s power management functions include enhanced clock control and various low- power (suspend) states (e.g., Suspend-to-RAM and Suspend-to-Disk). A hardware-based thermal management circuit permits software-independent entrance to low-power states. The Ibex Peak contains full support for the Advanced Configuration and Power Interface (ACPI) Specification, Revision 3.0a.

8.15 System Management Features

In addition to Intel AMT, the Ibex Peak integrates several functions designed to manage the system and lower the total cost of ownership (TCO) of the system. These system management functions are designed to report errors, diagnose the system, and recover from system lockups without the aid of an external microcontroller.

8.15.1 TCO Timer

The Ibex Peak’s integrated programmable TCO (Total Cost of Ownership) timer is used to detect system locks. The first expiration of the timer generates an SMI# that the system can use to recover from a software lock. The second expiration of the timer causes a system reset to recover from a hardware lock.

8.15.2 Processor Present Indicator

The Ibex Peak looks for the processor to fetch the first instruction after reset. If the processor does not fetch the first instruction, the Ibex Peak will reboot the system.

8.15.3 Error Code Correction (ECC) Reporting

When detecting an ECC error, the host controller has the ability to send one of several messages to the Ibex Peak. The host controller can instruct the Ibex Peak to generate an SMI#, NMI, SERR#, or TCO interrupt.

Page 37 of the Dell R210 user manual — 8.18 Intel Virtualization Technology for Directed I/O
Page 37 · click to enlarge
Page 37

8.15.4 Function Disable

The Ibex Peak provides the ability to disable the following integrated functions: LAN, USB, LPC, Intel HD Audio, SATA, PCI Express or SMBus. Once disabled, these functions no longer decode I/O, memory, or PCI configuration space. Also, no interrupts or power management events are generated from the disabled functions.

Intruder Detect. The Ibex Peak provides an input signal (INTRUDER#) that can be attached to a switch that is activated by the system case being opened. The Ibex Peak can be programmed to generate an SMI# or TCO interrupt due to an active INTRUDER# signal.

8.16 System Management Bus (SMBus 2.0)

The Ibex Peak contains an SMBus Host interface that allows the processor to communicate with SMBus slaves. This interface is compatible with most I2C devices. Special I2C commands are implemented.

The Ibex Peak’s SMBus host controller provides a mechanism for the processor to initiate communications with SMBus peripherals (slaves). Also, the Ibex Peak supports slave functionality, including the Host Notify protocol. Hence, the host controller supports eight command protocols of the SMBus interface (see System Management Bus

(SMBus) Specification, Version 2.0): Quick Command, Send Byte, Receive Byte, Write Byte/Word, Read Byte/Word, Process Call, Block Read/Write, and Host Notify.

Ibex Peak’s SMBus also implements hardware-based Packet Error Checking for data robustness and the Address Resolution Protocol (ARP) to dynamically provide address to all SMBus devices.

8.17 Intel Anti-Theft Technology

The Ibex Peak introduces a new hardware-based security technology which encrypts data stored on any SATA compliant HDD in AHCI Mode. This feature gives the end-user the ability to restrict access to HDD data by unknown parties. Intel Anti-Theft Technology can be used alone or can be combined with software encryption applications to add protection against data theft.

Intel Anti-Theft Technology functionality requires a correctly configured system, including an appropriate processor, Intel Management Engine firmware, and system BIOS support.

8.18 Intel Virtualization Technology for Directed I/O

The Ibex Peak provides hardware support for implementation of Intel Virtualization Technology with Directed I/O (Intel VT-d). Intel VT-d Technology consists of technology components that support the virtualization of platforms based on Intel Architecture Processors. Intel VT-d Technology enables multiple operating systems and applications to run in independent partitions. A partition behaves like a virtual machine (VM) and provides isolation and protection across partitions. Each partition is allocated its own subset of host physical memory.

Page 38 of the Dell R210 user manual — 8.19 JTAG Boundary-Scan
Page 38 · click to enlarge
Page 38

8.19 JTAG Boundary-Scan

Ibex Peak adds the industry standard JTAG interface and enables Boundary-Scan in place of the XOR chains used in previous generations of the Ibex Peak. Boundary-Scan can be used to ensure device connectivity during the board manufacturing process. The JTAG interface allows system manufacturers to improve efficiency by using industry available tools to test the Ibex Peak on an assembled board. Since JTAG is a serial interface, it eliminates the need to create probe points for every pin in an XOR chain. This eases pin breakout and trace routing and simplifies the interface between the system and a bed-of-nails tester.

Page 39 of the Dell R210 user manual — 9.1 Overview
Page 39 · click to enlarge
Page 39

9 BIOS

9.1 Overview

The following features are supported by BIOS:

  • System BIOS
  • System Setup
  • Onboard PCI video BIOS support
  • SATA enabled for CDROM and HDD
  • PCI FW3.0 compliant
  • PCI-to-PCI bridge 1.0 compliant
  • Plug and Play BIOS 1.0a compliant
  • MP 1.4
  • SMBIOS 2.5
  • USB 1.1 with legacy USB support
  • USB 2.0 support in BIOS during pre-boot
  • Dell Server Assistant 7.0 support
  • System Service support
  • iDRAC supported
  • Error logging via ESM
  • ACPI 2.0 support (S0, OS-S4, S5 states)
  • I2O v1.5 ready
  • Selectable Boot support based on BIOS Boot Specification v1.01
  • CD-ROM Boot 1.0
  • Remote BIOS Update support
  • Remote Configuration Interface (RCI) support
  • Console redirection via COM1
  • PXE support based on Preboot Execution Environment Specification v2.1
  • 2-byte ID support
  • ePPID support in flash
  • Memory remapping support
  • DDR3 UDIMM memory support
  • UEFI shell Support
  • IDRAC6/IDRAC6 Lite support
  • VT-d
  • IOAT
Page 40 of the Dell R210 user manual — PME# S5, OS-S4
Page 40 · click to enlarge
Page 40
  • AC recovery staggering Power-Up
  • DIMM mismatch checking
  • Support for multiple power profiles:
  • Static Maximum Performance Mode
  • OS Control ( DBS)
  • Active Power Controller
  • Custom

9.2 ACPI

ACPI complianceS0, S4, S5 supported

NO S1, S2, S3 (STR) support.

S4 will be supported by OS support only.

Table 14. Wake Up Events and States

Wake Up Events States Can Wake From

RTC S5, OS-S4

Power Button S5, OS-S4

PME# S5, OS-S4

WOL S5, OS-S4

9.3 Power Management Modes

9.3.1 Dell Active Power Controller

The Dell Active Power Controller (DAPC) is a Dell proprietary implementation that provides improved performance/watt over the OS implementation of Intel’s DBS. DAPC is implemented in system BIOS and uses hardware level counters, etc. to determine hardware utilization. The BIOS uses this information to determine when to change the processor’s operating frequency. The DAPC is OS independent and means that the OS no longer has control. This provides a consistent power management solution regardless of the installed OS. Some OS(s), particularly hypervisors, do not support power management, thus DAPC provides a solution when there otherwise would not be one.

Show 4 more labels / short text on this page
RI# Not supported · KB Not supported · MOUSE Not supported · USB Not supported
Page 41 of the Dell R210 user manual — Table 15. Summary of R210 Power Management Features
Page 41 · click to enlarge
Page 41

9.3.2 Power Saving BIOS Setting (OS Control)

Intel processors support Demand Based Switching (DBS) which enables the processor to dynamically change its operating frequency in response to workload changes. The industry standard implementation of this power management feature is in the Operating System (OS). The OS monitors process/thread level utilization of the processor and uses processor controls to change the processor’s operating frequency. For heavy workloads, the OS will run the processor at higher frequencies for additional performance. Lighter workloads do not need high performance, thus the OS will run the processor at lower frequencies.

9.3.3 Maximum Performance

The Maximum Performance Mode disables power management. In this mode, the processor frequency is statically set to the highest supported frequency.

The power management features are implemented via two categories: fixed or generic. Fixed features use bits defined in the ACPI specification for specific capabilities. The fixed feature bits give the OS complete control over the power management of a device since the location of the bits is given to the OS in the FACP table. Thus, a driver can directly access bits to control a device’s power management. Generic features have defined enable and status bits, but the functionality is not fully visible to the OS. Dell provides ASL code to handle the details of generic features, allowing the OS to intelligently communicate with system-specific hardware.

Table 15. Summary of R210 Power Management Features

Feature Type Enable/Status /Ctrl bit location

Fixed PCH The OS uses the SCI_EN bit to switch from legacy mode to ACPI mode.

Sleep states Fixed PCH Supported states: S0(Working), S4-OS (‘Hibernation’ in W2K), and S5 (Soft-off).

S1 (also called ‘standby’ or ‘suspend’) and S3 are not supported.

Power Button Fixed PCH In ACPI mode, OS has control of the power button. In non-ACPI mode, SMI handler owns power button events.

Fixed PCH The OS is able to configure the system to wake on the RTC alarm.

Power Mgmt. Timer

Fixed PCH 24-bit power management timer is used.

Power Mgmt. Event (PME)

Generic PCH Each host bus’s PME# signal is routed to a separate general-purpose event pin in the chipset. When a device signals PME#, the system wakes (if necessary), the OS detects the event, and a Dell defined ASL routine handles the event. Wake-on-LAN is one example of a PME.

Description · ACPI mode switch · Real-Time Clock

Page 42 of the Dell R210 user manual — Table 16. Power Profiles that R210 BIOS will Expose in BIOS Setup
Page 42 · click to enlarge
Page 42

USB wake Generic N/A This feature is not supported on this system since the S1 state is not supported.

DBS N/A Processor MSRs

This feature does P state transition under Windows

N/A Processor and PCH registers

This feature allows multiple C state supports for Processor. This feature will work under Windows and ACPI OS that understand C states.

N/A Processor/IMC and PCH chipset registers.

11G Servers will be the most energy smart servers that Dell will ship. In addition to P,C and T states, BIOS will expose the Power Profiles to the OS. Each Power profile will have a specific settings and it will fine tune processor, MCH, IOH and South Bridge. For detailed explanation on how this feature works, please look at BIOS Power Management specification located in Design Docs under R310 engineering.

Table 16. Power Profiles that R210 BIOS will Expose in BIOS Setup

Dell R210 — Table 16. Power Profiles that R210 BIOS will Expose in BIOS Setup diagram (page 42)
Fig. 26 · Table 16. Power Profiles that R210 BIOS will Expose…

Maximum Performance DBPM Disabled ( BIOS will set P-State to MAX)

OS Control Enable OS DBPM Control (BIOS will expose

Active Power Controller Enable DellSystem DBPM (BIOS will not make all P states available to OS)

Maximum Performance | Minimum Power | OS DBPM | System DBPM

Maximum Performance |1333Mhz |1067Mhz |800Mhz| Minimum Power Fan Algorithm

C State Support · Power Profile support

Page 43 of the Dell R210 user manual — Figure 13. PCIe x16 Riser Card
Page 43 · click to enlarge
Page 43

10 I/O Slots

10.1 Overview

The PowerEdge R210 system provides:

  • Riser support x16 PCIe card (Gen2 link x16)
  • Support x16 bandwidth card under 25W
Dell R210 — 10.1 Overview diagram (page 43)
Fig. 27 · 10.1 Overview

Figure 13. PCIe x16 Riser Card

Page 44 of the Dell R210 user manual — Figure 14. SAS 6/iR Adapter Card Installed
Page 44 · click to enlarge
Page 44
Dell R210 — 10.2 PCI Devices diagram (page 44)
Fig. 28 · 10.2 PCI Devices

Figure 14. SAS 6/iR Adapter Card Installed

10.2 PCI Devices

Xeon 3400 Series CPU PCI devices include:

  • Intel QuickPath Architecture Generic Non-core Registers
  • Intel QuickPath Architecture System Address Decoder
  • Intel QuickPath Interconnect Link 0
  • Intel QuickPath Interconnect Physical 0
  • Integrated Memory Controller General Registers
  • Integrated Memory Controller Target Address Decoder
  • Integrated Memory Controller Test Registers
  • Integrated Memory Controller Channel 0 Control
  • Integrated Memory Controller Channel 0 Address
  • Integrated Memory Controller Channel 0 Rank
  • Integrated Memory Controller Channel 0 Thermal Control
  • Integrated Memory Controller Channel 1 Control
  • Integrated Memory Controller Channel 1 Address
  • Integrated Memory Controller Channel 1 Rank
  • Integrated Memory Controller Channel 1 Thermal Control
  • DMI Root Port
  • PCI Express Root Port 1
  • PCI Express Root Port 3
Page 45 of the Dell R210 user manual — Table 17. I/O Slot Information
Page 45 · click to enlarge
Page 45
  • Core Addressing Mapping, Intel VT-d, System Management
  • Core Semaphore and Scratchpad Registers
  • Core System Control/Status Registers
  • Core Miscellaneous Control/Status Registers
  • Intel QuickPath Interconnect Link
  • Intel QuickPath Interconnect Routing and Protocol

Core i3/Pentium/Celeron CPU PCI devices include:

  • Host Bridge/DRAM Controller
  • Host-to-PCI Express Bridge
  • Internal Graphics Device
  • Secondary Host–to-PCI Express Bridge

PCH and Slots devices include:

  • Virtualization Engine Controller Interface (VECI)
  • USB HS EHCI Controller #2
  • PCI Express Port 1
  • PCI Express Port 2
  • PCI Express Port 3
  • PCI Express Port 4
  • PCI Express Port 5
  • PCI Express Port 6
  • PCI Express Port 7
  • PCI Express Port 8
  • USB HS EHCI Controller #1
  • DMI-to-PCI Bridge
  • LPC Controller1
  • SATA Controller #1 o Non-AHCI and Non-RAID Mode (Ports 0,1, 2 and 3) o Desktop Non-AHCI and Non-RAID Mode (Ports 0 and 1) o AHCI Mode (Ports 0-5) o AHCI Mode (Ports 0,1,4 and5) o RAID 0/1/5/10 mode
  • SMBus Controller
  • SATA Controller #2 o Non-AHCI and Non-RAID Mode (Ports 4 and 5)
  • Thermal Subsystem
  • Slot 1 PCI-E x16 [IIO]
  • BCM5716 (1)
  • BCM5716 (2)
  • Matrox ® G200eW w/ 8MB memory

The onboard devices are SATA, USB (x4), SMBus, IOxAPIC, and the LOM.

Table 17. I/O Slot Information

PCI Slot # Mechanical Electrical Height Length

1 PCIe x 16 PCIe x 16 Gen 2 Full Half

Page 46 of the Dell R210 user manual — Table 19. Bandwidth, Quantities, and Priorities
Page 46 · click to enlarge
Page 46

Table 18. PCI Card Dimensions

Dell R210 — Table 18. PCI Card Dimensions diagram (page 46)
Fig. 29 · Table 18. PCI Card Dimensions

Table 19. Bandwidth, Quantities, and Priorities

Dell R210 — Table 19. Bandwidth, Quantities, and Priorities diagram (page 46)
Fig. 30 · Table 19. Bandwidth, Quantities, and Priorities

Dell™ PERC S300 (SW RAID) PCIe x8 1 1

Dell™ PERC H200 (HW RAID) PCIe x8 1 1

Dell™ PERC 6E Adapter 256MB PCIe x8 1 1

Dell™ PERC 6E Adapter 512MB PCIe x8 1 1

Broadcom® NetXtreme™ II 5709 Dual Port Ethernet PCIe Card with TOE

Broadcom® NetXtreme™ II 5709 Dual Port Ethernet PCIe Card with TOE and iSCSI Offload

Broadcom® NetXtreme™ II BCM5709 Quad Port Ethernet PCIe™ Card with TOE and iSCSI Offload

Page 47 of the Dell R210 user manual — 10.4 NICs
Page 47 · click to enlarge
Page 47

10.3 Boot Order

The PowerEdge R210 supports only 1 PCIe x8 slot.

10.4 NICs

There is Broadcom 5716 chip on the PowerEdge R210 motherboard. The chip is connected to the PCH via a PCI Express x4 gen2 link. Broadcom 5716 does not support TOE (TCP Offload Engine).

The chip provides two Gigabit Ethernet ports. There are two RJ-45 connectors with integrated magnetic and LED on the rear of the system. The firmware for the LOM chip resides in a flash part.

The PowerEdge R210 supports Wake on LAN (WOL) from either port.

For listing of NICs supported on the R210, please see Section 10.1 Table 24

Page 48 of the Dell R210 user manual — Table 20. Available Drives
Page 48 · click to enlarge
Page 48

11 Storage

11.1 Overview

The PowerEdge R210 supports up to 2 HDDS:

  • 2 x 2.5”/ 3.5” cabled SATA or SSD from motherboard SATA connector
  • 2 x 2.5”/ 3.5” cabled SAS, SSD, or SATA via add-on storage controller

Customer must be selected at point of purchase. This is not an upgrade option for APOS.

11.2 Drives

Table 20. Available Drives

HDD Bays 2 x 3.5" or 2 x 2.5” Cabled only

HDD/SATA 3.5"/7.2K160, 250, or 1000GB, 2000GB
HDD/Near Line SAS 3.5"/7.2K1000GB, 2000GB
HDD/SAS 3.5”/15K146, 300, or 450GB, 600GB 3.5”/10K: 600GB 2.5”/10K: 146 or 300GB
HDD/SSD 2.5”or 50GB, 100GB

Drive Specifications

Page 49 of the Dell R210 user manual — 11.4 Optical Disk Drive (ODD)
Page 49 · click to enlarge
Page 49

11.3 RAID Configurations

Table 21. RAID Configurations

Dell R210 — Table 21. RAID Configurations diagram (page 49)
Fig. 31 · Table 21. RAID Configurations

Non-Mixed Drives, all SATA, all SSD, or ALL SAS

No HDD 0 NCZCBL No controller/No hard drive 0 0

1 MSTCBL On-board SATA Controller (Ibex Peak) 1 2

SATA Raid 2 MSTR0CBL Embedded SATA SW RAID – RAID0 2 2

3 MSTR1CBL Embedded SATA SW RAID – RAID1 2 2

4 ASSCBL Add-in SAS/SATA RAID card, No RAID (S300)

5 ASSCBL Add-in SAS/SATA RAID card, No RAID (S300) with 2 HDDs

6 ASSR0CBL Add-in SAS/SATA RAID card, RAID 0 (S300) 2 2

7 ASSR1CBL Add-in SAS/SATA RAID card, RAID 1 (S300) 2 2

8 ASSCBL Add-in SAS/SATA RAID card, No RAID (SAS 6/iR /H200 ) 1 2

9 ASSR0CBL Add-in SAS/SATA RAID card, RAID 0 (SAS 6/iR /H200) 2 2

10 ASSR1CBL Add-in SAS/SATA RAID card, RAID 1 (SAS 6/iR/H200 ) 2 2

11.4 Optical Disk Drive (ODD)

The PowerEdge R210 will support up to 1 slim type internal optical drive and optional external USB DVD-ROM. The PowerEdge R210 can boot from either the internal optical drive or the optional external drive and supports the following:

  • Configurations with no ODD
  • Optional internal DVD-ROM (SATA)
  • Optional internal DVD+RW (SATA)
Page 50 of the Dell R210 user manual — Table 22. Supported Tape Drives
Page 50 · click to enlarge
Page 50

11.5 Tape Drives

Table 22. Supported Tape Drives

PV DAS

Show 14 more labels / short text on this page
PowerVault™ MD1000 · PowerVault™ MD3000 · PowerVault™ MD1120 · PowerVault™ RD1000 · PowerVault™ 114X · PowerVault™ DAT 72 · External TBU · PowerVault™ LTO-3-060 · PowerVault™ 110T LTO-3 · PowerVault™ LTO4-120 · PowerVault™ ML6000 · External TBU/Automation · PowerVault™ 124T · PowerVault™ TL2000/TL4000
Page 51 of the Dell R210 user manual — 12.2 Audio
Page 51 · click to enlarge
Page 51

12 Video and Audio

12.1 Video

Matrox® G200eW w/ 8MB memory integrated in Winbond® WPCM450 (BMC controller):

  • 640x480 (60/72/75/85 Hz; 8/16/32-bit color)
  • 800x600 (60/72/75/85 Hz; 8/16/32-bit color)
  • 1024x768 (60/70/75/85 Hz; 8/16/32-bit color)
  • 1280x1024 (60/75/85 Hz; 8/16-bit color)
  • 1280x1024 (60 Hz, 32-bit color)

12.2 Audio

The PowerEdge R210 does not support audio (sound card or speakers).

Page 52 of the Dell R210 user manual — 13.3 Cable Management Arm (CMA)
Page 52 · click to enlarge
Page 52

13 Rack Information

13.1 Overview

The ReadyRails™ static rail system for the R210 provides tool-free support for racks with square or unthreaded round mounting holes (including Dell’s 42xx and 24xx series racks) with an adjustment range of 60–87 cm. The rails also offer tooled mounting support for 4-post threaded and 2-post (Telco) racks for added versatility.

13.2 Rails

The static rails for the R210 support tool-less mounting in 19”-wide, EIA-310-E compliant square hole and unthreaded round hole racks via Dell’s ReadyRails™ mounting interface. The rails also support a “generic” mounting interface for tooled mounting in threaded hole and 2-post (Telco) racks. Screws are not included in the kit since threaded racks are offered with a variety of thread designations. Users must provide their own screws when mounting the rails in threaded or 2-post racks.

Table 23. PowerEdge R210 Rail Information

Dell R210 — Table 23. PowerEdge R210 Rail Information diagram (page 52)
Fig. 32 · Table 23. PowerEdge R210 Rail Information

The adjustment range of the rails is a function of the type of rack in which they are being mounted. The min-max values listed below represent the allowable distance between the front and rear mounting flanges in the rack.

Figure 15. Rack Adjustability Range

Dell R210 — Figure 15. Rack Adjustability Range diagram (page 52)
Fig. 33 · Figure 15. Rack Adjustability Range

A4 ReadyRails™/Generic Static 608 879 594 872 604 890 622 —

13.3 Cable Management Arm (CMA)

The static rails for the R210 support a wide variety of racks and mounting configurations but do not support the ability to extend the system out of the rack for service. Thus, they do not provide support for a cable management arm (CMA).

Page 53 of the Dell R210 user manual — Table 24. Supported Microsoft Operating Systems
Page 53 · click to enlarge
Page 53

14 Operating Systems

For the most up-to-date information, see the Operating System Support Matrix for Dell PowerEdge Systems on Dell.com.

Table 24. Supported Microsoft Operating Systems

Dell R210 — Table 24. Supported Microsoft Operating Systems diagram (page 53)
Fig. 34 · Table 24. Supported Microsoft Operating Systems

Windows Server® 2008 R2 (Windows 7 includes SP2 bits)

Page 54 of the Dell R210 user manual — Table 25. Supported Linux Operating Systems
Page 54 · click to enlarge
Page 54

Table 25. Supported Linux Operating Systems

Dell R210 — Table 25. Supported Linux Operating Systems diagram (page 54)
Fig. 35 · Table 25. Supported Linux Operating Systems

Novell® SUSE® Linux® Enterprise S10 SP3

Page 55 of the Dell R210 user manual — Table 26. Supported Virtualization OS
Page 55 · click to enlarge
Page 55

15 Virtualization

Table 26. Supported Virtualization OS

Virtualization OS Install Method

VMware® ESX 4 update 1 DIB

Embedded VMware ESXi 4 update 1

VMWare ESX 3.5.1 Supported; not offered through Dell (No FI nor DIB)

VMWare ESXi 3.5.1 Supported; not offered through Dell (No FI or DIB)

Website download fulfillment; instructions are DIB

PlateSpin® PowerConvert®

Vizioncore™ suitevRanger™ Pro vConverter™ vReplicator vFoglight™

Website download fulfillment; instructions are DIB

Download version

Page 56 of the Dell R210 user manual — 16.2 Server Management
Page 56 · click to enlarge
Page 56

16 Systems Management

16.1 Overview

Dell delivers open, flexible, and integrated solutions that help you reduce the complexity of managing disparate IT assets by building comprehensive IT management solutions. Combining Dell PowerEdge Servers with a wide selection of Dell-developed management solutions gives you choice and flexibility, so you can simplify and save in environments of any size. To help you meet your server performance demands, Dell offers Dell OpenManage systems management solutions for:

  • Deployment of one or many servers from a single management console
  • Monitoring of server and storage health and maintenance
  • System update, configuration change, and maintenance Dell offers IT management solutions for organizations of all sizes—priced, sized, and supported right.

16.2 Server Management

A Dell Systems Management and Documentation DVD and a Dell Management Console DVD are included with the product. Content includes:

  • Dell Systems Build and Update Utility : Dell Systems Build and Update Utility assists in OS install and pre-OS hardware configuration and updates.
  • OpenManage Server Administrator : The OpenManage Server Administrator (OMSA) tool provides a comprehensive, one-to-one systems management solution, designed for system administrators to manage systems locally and remotely on a network. OMSA allows system administrators to focus on managing their entire network by providing comprehensive one-to-one systems management.
  • Management Console : Our legacy IT Assistant console is also included, as well as tools to allow access to our remote management products. These tools are Remote Access Service for iDRAC and the BMC Management Utility.
  • Active Directory Snap-in Utility : The Active Directory Snap-in Utility provides an extension snap-in to the Microsoft Active Directory. This allows you to manage Dell specific Active Directory objects. The Dell-specific schema class definitions and their installation are also included on the DVD.
  • Dell Systems Service Diagnostics Tools : Dell Systems Service and Diagnostics tools deliver the latest Dell optimized drivers, utilities, and operating system-based diagnostics that you can use to update your system.
  • eDocs : The section includes PDF files for PowerEdge systems, storage peripheral, and OpenManage software.
  • Dell Management Console DVD : The Dell Management Console is a Webbased systems management software that enables you to discover and inventory devices on your network. It also provides advanced functions, such as health and performance monitoring of networked devices and patch management capabilities for Dell systems.
Page 57 of the Dell R210 user manual — 16.4 Lifecycle Controller and Unified Server Configurator
Page 57 · click to enlarge
Page 57
  • Server Update Utility : In addition to the Systems Management Tools and Documentation and Dell Management Console DVDs, customers have the option to obtain Server Update Utility DVD. This DVD has an inventory tool for managing updates to firmware, BIOS, and drivers for either Linux or Windows operating systems.

16.3 Embedded Server Management

The PowerEdge R210 implements circuitry for the next generation of embedded server management. It is Intelligent Platform Management Interface (IPMI) v2.0 compliant. The optional iDRAC (Integrated Dell Remote Access Controller) is responsible for acting as an interface between the host system and its management software and the periphery devices. These periphery devices consist of the PSUs, the storage backplane, integrated SAS HBA or PERC 6/I, and control panel with display.

The optional upgrade to iDRAC6 provides features for managing the server remotely or in data center lights-out environments.

Advanced iDRAC features require the installation of the optional iDRAC6 Enterprise card.

16.4 Lifecycle Controller and Unified Server Configurator

Embedded management is comprised of four key components:

  • Dell Lifecycle Controller
  • Dell Unified Server Configurator
  • iDRAC6 (Integrated Dell Remote Access Controller)
  • vFlash (virtual flash media) Lifecycle Controller powers the embedded management features. It is integrated and tamperproof storage for system-management tools and enablement utilities (firmware, drivers, etc.).

Dell Unified Server Configurator (USC) is a local 1:1 graphical user interface embedded on Lifecycle Controller that aids in local server provisioning in a pre-OS environment. For servers with iDRAC Express, the Lifecycle Controller offers OS install, platform updates, platform configuration, and diagnostics capabilities. For servers without iDRAC6 Express, this utility has limited functionality and offers OS install and diagnostics capabilities only.

To access the Unified Server Configurator, press the key within 10 seconds of the Dell logo’s appearance during the system boot process. Current functionality enabled by the Unified Server Configurator is detailed in the following table.

Page 58 of the Dell R210 user manual — 16.6 iDRAC6 Enterprise
Page 58 · click to enlarge
Page 58

Table 27. Unified Server Configurator Features and Description

Faster O/S Installation Drivers and the installation utility are embedded on system

Faster System Updates Integration with Dell support automatically directed to latest versions of the Unified Server Configurator, iDRAC, RAID, BIOS, NIC, and Power Supply

Update Rollback Ability to recover to previous known good state for all updatable components

More Comprehensive Diagnostics Diagnostic utilities are embedded on system

Simplified Hardware Configuration Detects RAID controller and allows user to configure virtual disk and choose virtual disk as boot device, eliminating the need to launch a separate utility. Also provides configuration for iDRAC, BIOS, and NIC/LOM.

16.5 iDRAC6 Express

The optional iDRAC6 Express is the first tier of iDRAC6 upgrades. In addition to upgrading the system with a Lifecycle Controller, the iDRAC6 Express offers the following key features:

  • Graphical web interface
  • Standard-based interfaces
  • Server Sensor monitoring and fault alerting
  • Secure operation of remote access functions including authentication, authorization, and encryption
  • Power control and management with the ability to limit server power consumption and remotely control server power states
  • Advanced troubleshooting capabilities For more information on iDRAC6 Express features see table below.

16.6 iDRAC6 Enterprise

The optional iDRAC6 Enterprise card provides access to advanced iDRAC6 features. The iDRAC6 Enterprise connects directly to the R210 planar and is mounted parallel to the planar with stand-offs.

Key features for the iDRAC6 Enterprise include:

  • Scripting capability with Dell’s Racadm command-line
  • Remote video, keyboard, and mouse control with Virtual Console
  • Remote media access with Virtual Media
  • Dedicated network interface Additionally, the iDRAC6 Enterprise can be upgraded by adding the vFlash Media card. This is a 1 GB Dell branded SD card that enables a persistent 256 or 512 MB virtual

Feature Description

Page 59 of the Dell R210 user manual — Table 28. Features List for BMC, iDRAC6, and vFlash
Page 59 · click to enlarge
Page 59

flash partition. A more detailed feature list for iDRAC6 Enterprise and vFlash is included in the following table.

Table 28. Features List for BMC, iDRAC6, and vFlash

Dell R210 — Table 28. Features List for BMC, iDRAC6, and vFlash diagram (page 59)
Fig. 36 · Table 28. Features List for BMC, iDRAC6, and vFlash
Page 60 of the Dell R210 user manual — 16.5 iDRAC6 Express
Page 60 · click to enlarge
Page 60
Dell R210 — 16.5 iDRAC6 Express diagram (page 60)
Fig. 37 · 16.5 iDRAC6 Express
Page 61 of the Dell R210 user manual — 17.2 USB Device
Page 61 · click to enlarge
Page 61

17 Peripherals

17.1 USB

All PowerEdge systems have a minimum of 2 front-accessible USB 2.0 compliant ports with enough spacing around to accommodate full usage of both connectors simultaneously along with any/all other front panel features (Video connector, buttons, LED’s, etc.) without mechanical interference. These ports are connected to the same controller and not shared with internal or back USB ports

For security reasons, all external USB ports must have an enable/disable function.

Disabling USB controllers must observe the hierarchy in Table 29 (listed from lowest to highest priority in a 4 controller design).

Internal USB ports connected to internal persistent storage devices have an enable/disable function independent of the other ports present in the system.

Table 29. USB Controller Priorities

USB Controller Function If Disabled

4 (Lowest) Internal USB peripherals No other Controller is disabled

3 Front USB Controller 4 is disabled as well

2 Back USB Controllers 3 & 4 are disabled as well

1 (Highest) Remote Access (RAC) Controllers 2,3, & 4 are disabled as well

The above hierarchy dictates that connections that are lower in the hierarchy must be disabled anytime a higher level connection is disabled (e.g., when Back USB is disabled the Front USB ports are also disabled).

17.2 USB Device

Optional external USB DVD-ROM.

Page 62 of the Dell R210 user manual — Table 30. External Storage
Page 62 · click to enlarge
Page 62

17.3 External Storage

Table 30. External Storage

Dell R210 — Table 30. External Storage diagram (page 62)
Fig. 38 · Table 30. External Storage
Page 63 of the Dell R210 user manual — Table 32. EMF Single Pack Dimensions and Weights
Page 63 · click to enlarge
Page 63

18 Packaging Options

Options for single pack and multipack are available. Multipack will support 4 units in one pack.

Table 31. AMF Single Pack Dimensions and Weights

INSIDE DIMENSIONS OUTSIDE DIMENSIONS WEIGHT

Length81.3 cm (32”)
Length82.9 cm (32.63”)

System packed out weight:

Width59.4 cm (23.38”)
Width61 cm (24”)

PowerEdge R210: 9.71 kg (21.42 lbs) Cushion: 0.42 kg (.93 lbs) Corrugated Box: 2.75 kg (6.05 lbs)

Depth23.5 cm (9.25”)
Depth26.7 cm (10.5”)
Total Weight12.88 kg (28.4 lbs)

Table 32. EMF Single Pack Dimensions and Weights

INSIDE DIMENSIONS OUTSIDE DIMENSIONS WEIGHT

Length61.9 cm (24.38”)
Length63.5 cm (25.00”)

System packed out weight:

Width59.4 cm (23.38”)
Width61 cm (24”)

PowerEdge R210: 8.56 kg (18.87 lbs) Cushion: 0.36 kg (.80 lbs) Corrugated Box: 2.06 kg (4.55 lbs)

Depth24.1 cm (9.50”)
Depth27.3 cm (10.75”)
Total Weight10.98 kg (24.2 lbs)
Page 64 of the Dell R210 user manual — Figure 16. Packaging
Page 64 · click to enlarge
Page 64
Dell R210 — 18 Packaging Options diagram (page 64)
Fig. 39 · 18 Packaging Options

Figure 16. Packaging

Page 65 of the Dell R210 user manual — Appendix A. Regulatory Certifications
Page 65 · click to enlarge
Page 65

Appendix A. Regulatory Certifications

  • FCC (U.S. only) Class A
  • ICES (Canada) Class A
  • CE Mark (EN 55022 Class A, EN55024, EN61000-3-2, EN61000-3-3)
  • VCCI (Japan) Class A
  • BSMI (Taiwan) Class A
  • C-Tick (Australia/New Zealand) Class A
  • NRCS/SABS (South Africa) Class A
  • CCC (China) Class A
  • KCC (Korea) Class A
  • UL 60950-1
  • CAN/CSA C22.2 No. 60950-1
  • EN 60950-1
  • IEC 60950-1
  • IRAM (Argentina)
  • NOM (Mexico)
  • Bellis (Belarus)
  • Koncar (Croatia)
  • TUV GS (Germany)
  • SII (Israel)
  • CKT (Kazakhstan)
  • KEBS (Kenya)
  • INSM (Moldova)
  • Soncap (Nigeria)
  • Nemko (Norway)
  • GOST (Russia)
  • KVALITET (Serbia, Bosnia, Herzegovina, Montenegro)
  • UKRTEST (Ukraine)
  • UZBEKISTAN GOST (Uzbekistan)
  • KUCAS (Kuwait)
  • KSA-ICCP (Saudi Arabia)
  • MPT (Vietnam)
Page 66 of the Dell R210 user manual — Table 33. PowerEdge R210 Volatility
Page 66 · click to enlarge
Page 66

Appendix B. R210 Volatility Tables

Table 33. PowerEdge R210 Volatility

Dell R210 — Table 33. PowerEdge R210 Volatility diagram (page 66)
Fig. 40 · Table 33. PowerEdge R210 Volatility

System BIOS SPI Flash Y SYS_S PI 1 4MB Flash EEPROM (SPI interface)

Page 67 of the Dell R210 user manual — 18 Packaging Options
Page 67 · click to enlarge
Page 67
Dell R210 — 18 Packaging Options diagram (page 67)
Fig. 41 · 18 Packaging Options

2 User selectable License key hard set ROM or user choice

vFlash Y J_SD (conne ctor) 1 1GB Secure Digital NAND Flash

Page 68 of the Dell R210 user manual — Table 34. Volatility: Data Writing and Purpose
Page 68 · click to enlarge
Page 68

Table 34. Volatility: Data Writing and Purpose

Dell R210 — Table 34. Volatility: Data Writing and Purpose diagram (page 68)
Fig. 42 · Table 34. Volatility: Data Writing and Purpose

Can user programs or operating system write data to it during normal operation?

No for iDRAC Operating System; Yes for Managed System Services Repository

iDRAC Operating System plus Managed System Services Repository (i.e., Unified Server Configurator, OS drivers, diagnostics, rollback versions of various programmables)

No BIOS binding of plug in module to a particular planar.

iDRAC boot loader and configuration (i.e. MAC address), Lifecycle log. nd system event log.

iDRAC6 Boot Block Flash yes Storage of encryption keys

No BIOS binding of plug-in module to a particular planar

Page 69 of the Dell R210 user manual — Table 35. Methodology for Data Input to Memory
Page 69 · click to enlarge
Page 69
Dell R210 — 18 Packaging Options diagram (page 69)
Fig. 43 · 18 Packaging Options

Can user programs or operating system write data to it during normal operation?

Internal USB Yes as allowed by OS Normal usage is read only software license key, but not limited

vFlash Yes when enabled, installed, and the media does not have the write protect switch applied

Storage of logs, user images such as files, drivers, and Operating Systems

Table 35. Methodology for Data Input to Memory

How is data input to this memory?

System BIOS SPI Flash Loading flash memory requires a vendor-provided firmware file and loader program which is executed by booting the system from a floppy or OS-based executable containing the firmware file and the loader. System loaded with arbitrary data in firmware memory will not operate

Loading flash memory requires a vendor-provided firmware file and loader program which is executed by booting up the system from a floppy or OS based executable containing the firmware file and the loader. LOMs loaded with arbitrary data in firmware memory will not operate.

iDRAC6 Controller RAM iDRAC embedded system

System CPLD Loading flash memory requires a vendor-provided firmware file and loader program which is executed by booting up the system from a floppy or OS-based executable (currently only DRMK utility support) containing the firmware file and the loader. System loaded with arbitrary data in CPLD memory will not operate.

iDRAC6 Express Internal Flash Not used

iDRAC OS: Loading flash memory requires a vendor-provided firmware file and loader program which is executed by booting the system from a floppy or OS-based executable containing the firmware file and the loader. System loaded without a good iDRAC firmware image yields a non-functional iDRAC.

Planar · LOM Configuration Data · System RAM

Page 70 of the Dell R210 user manual — 18 Packaging Options
Page 70 · click to enlarge
Page 70

How is data input to this memory? Managed Services Repository: Various partitions are loaded using vendor-provided firmware file and loader program just like iDRAC OS.

TPM ID EEPROM (Plug- in module only) Factory loaded only

TPM Binding EEPROM (on China planar only) BIOS only

iDRAC6 SDRAM Embedded iDRAC OS for 108MB and 8MB for VGA frame buffer

iDRAC6 FRU Factory and iDRAC embedded OS

iDRAC6 Boot Block Flash

Loading flash memory requires a vendor-provided firmware file and loader program which is executed by booting up the system from a floppy or OS-based executable or out of band firmware updates across the management network. Bad contents yield the iDRAC inoperable and unrecoverable in the customer environment. The lifecycle log is automatically updated by the iDRAC as various system component firmware, hardware, and software versions change.

Using TPM-enabled operating systems; except in China where TCM is used.

CMOS BIOS control only via input such as BIOS F2 menu user configuration settings (such as boot order)

Internal USB Either read only license key or OS control copies

vFlash Preloaded media before installation, or remote out-of-band upload of user data (i.e., ISO images, files) or local server read/write capability to use like a hard disk.

Show 4 more labels / short text on this page
Trusted Platform Module · Chipset · Control Panel · iDRAC6 Enterprise
Page 71 of the Dell R210 user manual — Table 36. Methodology for Memory Protection and Clearing
Page 71 · click to enlarge
Page 71

Table 36. Methodology for Memory Protection and Clearing

Dell R210 — Table 36. Methodology for Memory Protection and Clearing diagram (page 71)
Fig. 44 · Table 36. Methodology for Memory Protection and Clea…

How is this memory write protected? How is the memory cleared?

Not possible with any utilities or applications and system is not functional if corrupted/removed.

No explicitly protected but special applications are needed to communicate through the LOMs to reprogram this ROM

Not possible with any utilities or applications and system is not functional if corrupted/removed.

Writes are proxied through a temporary iDRAC scratchpad RAM and not directly made from an OS or OS application

System RAM OS control Reboot or power down system

Page 72 of the Dell R210 user manual — CMOS
Page 72 · click to enlarge
Page 72

TPM Binding EEPROM (on China planar only)

Locked by BIOS from physical access by anyone after boot

Not applicable, BIOS control only

iDRAC6 SDRAM n/a AC cycle for BMC OS and reset/power off server for VGA frame buffer

iDRAC6 FRU writes controlled by iDRAC embedded OS

EPPID is not clearable

iDRAC6 Boot Block Flash

iDRAC embedded OS control of the write protection

Not possible with any utilities or applications and iDRAC does not function as expected if corrupted/removed. Lifecycle log is clearable only in a factory environment; System Event Log is user clearable

SW write protected F2 Setup option

CMOS

Planar NVRAM_CLR jumper or by removal of AC cord, cover, and coin cell battery, then waiting 30 seconds prior to replacement of battery, cover and AC cord.; F2 system setup option is used to restore defaults

N/A, BIOS only control

Internal USB OS control OS control format

vFlash Media write protection switch or OS control

iDRAC-based format, local OS format, deleted, or card removed and formatted on a client

Show 4 more labels / short text on this page
Trusted Platform Module · Chipset · Control Panel · iDRAC6 Enterprise
Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Dell R210

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Dell R210

Be the first to ask — other owners or our team will answer.

Original document

Dell R210 manual PDF

72 pages·1.1 MB·Life Jacket·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…