Copyright © 2014 Dell Inc. All rights reserved. This product is protected by U.S. and international copyright and intellectual property laws. Dell™ and the Dell logo are trademarks of Dell Inc. in the United States and/or other jurisdictions. All other marks and names mentioned herein may be trademarks of their respective companies.
Rev. A00
2013 - 03















Dell OpenManage Server Administrator generates event messages stored primarily in the operating system or Server Administrator event logs and sometimes in Simple Network Management Protocol (SNMP) traps. This document describes the event messages that are created by Server Administrator version 7.1.2 and displayed in the Server Administrator alert log.
Server Administrator creates events in response to sensor status changes and other monitored parameters. The Server Administrator event monitor uses these status change events to add descriptive messages to the operating system event log or the Server Administrator alert log.
Each event message that Server Administrator adds to the alert log consists of a unique identifier called the event ID for a specific event source category and a descriptive message. The event message includes the severity, cause of the event, and other relevant information, such as the event location and the previous state of the monitored item.
The tables in this guide list all Server Administrator event IDs in numeric order. Each entry includes the description, severity level, and cause of the event ID. The message text in angle brackets (for example, (for example, <State>) describes the event-specific information provided by the Server Administrator.
New Alert messages for Instrumentation Service — 1015 and 1016.
New Alert messages for Non-Volatile Memory Express (NVMe) — 2440, 2441, 2442, 2443 and 2445.
The following table describes the changes made to the Storage Management alerts from the previous release of Storage Management to the current release.
Table 1. Alert Message Change History
Storage Management 4.4
Product Versions to which changes apply
Storage Management 4.4.0 Server Administrator 7.4.0
New Alerts 1015, 1016
Deleted Alerts 1250, 1253, 1255, 1350, 1355, 1450, 1451, 1452, 1453, 1454, 1455, 1500, 1501, 1502, 1503, 1504, 1505, 1600, 1605
Storage Management 4.3
Product Versions to which changes apply
Storage Management 4.3.0 Server Administrator 7.3.0
New Alerts 2699, 2700, 2701, 2702, 2703, 2704, 2705, 2874, 2875, 2876, 2900, 2901, 2902, 2903, 2904, 2905, 2906, 2907, 2908,
Modified Alerts None

2909, 2910, 2911, 2912, 2913, 2914, 2915, 2916, 2917, 2918, 2919, 2920, 2921, 2922, 2923, 2924, 2930, 2931, 2932, 2933
Storage Management 4.2
Product Versions to which changes apply
Storage Management 4.2.0 Server Administrator 7.2.0
New Alerts 2433, 2434, 2435, 2436, 2437, 2438
Storage Management 4.1
Product Versions to which changes apply
Storage Management 4.1.0 Server Administrator 7.1.0
Storage Management 4.0
Product Versions to which changes apply
Storage Management 4.0.0 Server Administrator 7.0.0
New Alerts 2425, 2426, 2429, 2430, 2431
Storage Management 3.5
Product Versions to which changes apply
Storage Management 3.5.0 Server Administrator 6.5.0
Modified Alerts 2388, 2347, 2081
Storage Management 3.4
Product Versions to which changes apply
Storage Management 3.4.0 Server Administrator 6.4.0
New Alerts 2405, 2406, 2407, 2408, 2409, 2410, 2411, 2412, 2413, 2414, 2415, 2416, 2417, 2418

Storage Management 3.3
Product Versions to which changes apply
Storage Management 3.3.0 Server Administrator 6.3.0
New Alerts 2394, 2395, 2396, 2397, 2398, 2399, 2400, 2401, 2402, 2403, 2404
Modified Alerts Alert severity changed for 1151 and 1351
Storage Management 3.2
Product Versions to which changes apply
Storage Management 3.2.0 Server Administrator 6.2.0
New Alerts 2387, 2388, 2389, 2390, 2392, 2393
This guide describes only event messages logged by Server Administrator and Storage Management that are displayed in the Server Administrator alert log. For information on other messages generated by your system, see one of the following sources:
Add your section content here.This section describes the various types of event messages generated by the Server Administrator. When an event occurs on your system, Server Administrator sends information about one of the following event types to the systems management console: Table 2. Understanding Event Messages
Icon Alert Severity Component Status
OK /Normal / Informational
An event that describes the successful operation of a unit. The alert is provided for informational purposes and does not indicate an error condition. For example, the alert may indicate the normal start or stop of an operation, such as power supply or a sensor reading returning to normal.
An event that is not necessarily significant, but may indicate a possible future problem. For example, a Warning/Non-critical alert may indicate that a component (such as a

Icon Alert Severity Component Status
temperature probe in an enclosure) has crossed a warning threshold.
Critical / Failure / Error
A significant event that indicates actual or imminent loss of data or loss of function. For example, crossing a failure threshold or a hardware failure such as an array disk.
Server Administrator generates events based on status changes in the following sensors:
The following example shows the format of the event messages logged by Server Administrator.

An event log is used to record information about important events.
Server Administrator generates alerts that are added to the operating system event log and to the Server Administrator alert log. To view these alerts in Server Administrator:
You can also view the event log using your operating system’s event viewer. Each operating system’s event viewer accesses the applicable operating system event log.
The location of the event log file depends on the operating system you are using.
NOTE: The Server Administrator event log file is named dcsys32.xml and is located in the \omsa\log directory. The default install_path is C:\Program Files\Dell\SysMgt. • On systems running the Red Hat Enterprise Linux, SUSE Linux Enterprise Server, Citrix XenServer, VMware ESX, and VMware ESXi operating systems, the event messages are logged in the operating system log file and the Server Administrator event log.
NOTE: The default name of the operating system log file is /var/log/messages, and you can view the operating system log file using a text editor such as vi or emacs. The Server Administrator event log file is named dcsys.xml,where xx is either 32 or 64 bit depending on the operating system. In the Red Hat Enterprise Linux, SUSE Linux Enterprise Server, Citrix XenServer and VMware ESX operating systems, the Server Administrator event log file is located in the /opt/ dell/srvadmin/var/log/openmanage directory. In the VMware ESXi operating system, the Server Administrator event log file is located in the /etc/cim/dell/srvadmin/log/openmanage directory.
Logging messages to a Unicode text file is optional. By default, the feature is disabled in the Server Administrator. To enable this feature, modify the Event Manager section of the dcemdy .ini configuration file where xx is 32 or 64 bit depending on the operating system, as follows:
The following sub-sections explain how to launch the Windows Server 2008, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, VMware ESX, and VMware ESXi event viewers.

The System Log window displays a list of recently logged events.
The following example shows the Red Hat Enterprise Linux and SUSE Linux Enterprise Server message log, /var/log/messages. The text in boldface type indicates the message text.
Feb 6 14:20:51 server01 Server Administrator: Instrumentation Service EventID: 1000
Feb 6 14:20:51 server01 Server Administrator: Instrumentation Service EventID: 1001
Server Administrator startup complete
Feb 6 14:21:21 server01 Server Administrator: Instrumentation Service EventID: 1254Chassis intrusion detected Sensor location: Main chassis intrusion Chassis location: Main System Chassis Previous state was: OK (Normal) Chassis intrusion state: Open
Feb 6 14:21:51 server01 Server Administrator: Instrumentation Service EventID: 1252Chassis intrusion returned to normal Sensor location: Main chassis intrusion Chassis location: Main System Chassis Previous state was: Critical (Failed) Chassis intrusion state: Closed
The event log for each operating system contains some or all of the following information:
Server Administrator starting

Table below lists in alphabetical order each line item that may appear in the event description.
Explanation Specifies the action that was performed, for example: Action performed was: Power cycle
Explanation Specifies the action that was requested, for example: Action requested was: Reboot, shutdown OS first
Explanation Specifies additional details available for the hot plug event, for example: Memory device: DIMM1_A Serial number: FFFF30B1
Explanation Specifies information pertaining to the event, for example: Power supply input AC is off, Power supply POK (power OK) signal is not normal, Power supply is turned off
Explanation Specifies whether the chassis intrusion state is Open or Closed. For example: Chassis intrusion state: Open
Explanation Specifies name of the chassis that generated the message, for example: Chassis location: Main System Chassis

Explanation Specifies the type of configuration error that occurred, for example: Configuration error type: Revision mismatch
Explanation Specifies the current sensor value in amps, for example: Current sensor value (in Amps): 7.853
Explanation Specifies the date and time the action was performed, for example: Date and time of action: Sat Jun 12 16:20:33 2004
Explanation Specifies the location of the device in the specified chassis, for example: Device location: Memory Card A
Explanation Specifies the state of the current sensor, for example: Discrete current state: Good
Explanation Specifies the state of the temperature sensor, for example: Discrete temperature state: Good
Explanation Specifies the state of the voltage sensor, for example: Discrete voltage state: Good
Explanation Specifies the fan speed in revolutions per minute (RPM) or On/Off, for example: Fan sensor value (in RPM): 2600
Explanation Specifies the type of hardware log, for example: Log type: ESM

Explanation Specifies the name of the memory bank in the system that generated the message, for example: Memory device bank location: Bank_1
Explanation Specifies the location of the memory module in the chassis, for example: Memory device location: DIMM_A
Number of devices required for full redundancy:
Explanation Specifies the number of power supply or cooling devices required to achieve full redundancy, for example: Number of devices required for full redundancy: 4
Peak value (in Watts):
Explanation Specifies the peak value in Watts, for example: Peak value (in Watts): 1.693
Explanation Specifies a list of possible causes for the memory module event, for example: Possible memory module event cause:
Single bit warning error rate exceeded
Single bit error logging disabled
Explanation Specifies the type of power supply, for example: Power Supply type: VRM
Explanation Specifies the status of the previous redundancy message, for example: Previous redundancy state was: Lost
Previous state was:
Explanation Specifies the previous state of the sensor, for example: Previous state was: OK (Normal)
Explanation Specifies the status of the processor sensor, for example: Processor sensor status: Configuration error

Explanation Specifies the location of the redundant power supply or cooling unit in the chassis, for example: Redundancy unit: Fan Enclosure
Explanation Specifies the type of SD card device, for example: SD card device type: Hypervisor
Explanation Specifies the state of the SD card, for example: SD card state: Present, Active
Explanation Specifies the location of the sensor in the specified chassis, for example: Sensor location: CPU1
Explanation Specifies the temperature in degrees Celsius, for example: Temperature sensor value (in degrees Celsius): 30
Voltage sensor value (in Volts):
Explanation Specifies the voltage sensor value in volts, for example: Voltage sensor value (in Volts): 1.693

The following tables lists in numerical order each event ID and its corresponding description, along with its severity and cause.
The messages below indicate that certain alert systems are up and working.
Description Log was cleared
Cause User cleared the log from Server Administrator.
This operation does not clear the operating system event log. Therefore, this event is not logged in the operating system event log. This is logged in the System Administrator alert log.
Description Log backup created
Cause The log was full, copied to backup, and cleared.
Description Server Administrator starting
Cause Server Administrator is beginning to initialize.
Description Server Administrator startup complete
Cause Server Administrator completed initialization.

Description A system BIOS update has been scheduled for the next reboot
Cause The user has chosen to update the flash basic input/output system (BIOS).
Description A previously scheduled system BIOS update has been canceled
Cause The user decides to cancel the flash BIOS update, or an error occurs during the flash.
Description Thermal shutdown protection has been initiated
Cause This message is generated when a system is configured for thermal shutdown due to an error event. If a temperature sensor reading exceeds the error threshold for which the system is configured, the operating system shuts down and the system powers off. This event may also be initiated on certain systems when a fan enclosure is removed from the system for an extended period of time.
Description SMBIOS data is absent
Cause The system does not contain the required systems management BIOS version 2.2 or higher, or the BIOS is corrupted.
Description Automatic System Recovery (ASR) action was performed Action performed was:
Date and time of action:
Cause This message is generated when an automatic system recovery action is performed due to a hung operating system. The action performed and the time of action is provided.

Description User initiated host system control action Action requested was:
Cause User requested a host system control action to reboot, power off, or power cycle the system. Alternatively, the user had indicated protective measures to be initiated in the event of a thermal shutdown.
Description Systems Management Data Manager Started
Cause Systems Management Data Manager services were started.
Description Systems Management Data Manager Stopped
Cause Systems Management Data Manager services were stopped.
Description RCI table is corrupt
Cause This message is generated when the BIOS Remote Configuration Interface (RCI) table is corrupted or cannot be read by the systems management software.
Cause This message is generated to indicate the Intelligent Platform Management Interface (IPMI) status of the system.
Additional information, when available, includes Baseboard Management Controller (BMC) not present, BMC not responding, System Event Log (SEL) not present, and SEL Data Record (SDR) not present.

Description System Peak Power detected new peak value Peak value (in Watts):
Cause The system peak power sensor detected a new peak value in power consumption. The new peak value in Watts is provided.
Cause This event is generated when the systems management agent detects a critical system software generated event in the system event log which could have been resolved.
Description Server Based Management Mode is enabled
Cause This event is generated when the server-based management mode is enabled.
Description Server Based Management Mode is disabled
Cause This event is generated when the server-based management mode is disabled.
The temperature sensors listed help protect critical components by alerting the systems management console when temperatures become too high inside a chassis. The temperature sensor messages use more variables: sensor location, chassis location, previous state, and temperature sensor value or state.
Description Temperature sensor has failed Sensor location:
If sensor type is not discrete:

Temperature sensor value (in degrees Celsius):
If sensor type is discrete:
Cause A temperature sensor on the backplane board, system board, or the carrier in the specified system failed. The sensor location, chassis location, previous state, and temperature sensor value are provided.
Description Temperature sensor value unknown Sensor location:
If sensor type is not discrete:
Temperature sensor value (in degrees Celsius):
If sensor type is discrete:
Cause A temperature sensor on the backplane board, system board, or drive carrier in the specified system could not obtain a reading. The sensor location, chassis location, previous state, and a nominal temperature sensor value information is provided.
Description Temperature sensor returned to a normal value Sensor location:
If sensor type is not discrete:
Temperature sensor value (in degrees Celsius):
If sensor type is discrete:
Cause A temperature sensor on the backplane board, system board, or drive carrier in the specified system returned to a valid range after crossing a failure threshold. The sensor location, chassis location, previous state, and temperature sensor value are provided.
Description Temperature sensor detected a warning value Sensor location:
Severity Error · Severity Warning · Severity Information

If sensor type is not discrete:
Temperature sensor value (in degrees Celsius):
If sensor type is discrete:
Cause A temperature sensor on the backplane board, system board, CPU, or drive carrier in the specified system exceeded its warning threshold. The sensor location, chassis location, previous state, and temperature sensor value are provided.
Description Temperature sensor detected a failure value Sensor location:
If sensor type is not discrete:
Temperature sensor value (in degrees Celsius):
If sensor type is discrete:
Cause A temperature sensor on the backplane board, system board, or drive carrier in the specified system exceeded its failure threshold. The sensor location, chassis location, previous state, and temperature sensor value are provided.
Description Temperature sensor detected a non-recoverable value Sensor location:
If sensor type is not discrete:
Temperature sensor value (in degrees Celsius):
If sensor type is discrete:
Cause A temperature sensor on the backplane board, system board, or drive carrier in the specified system detected an error from which it cannot recover. The sensor location, chassis location, previous state, and temperature sensor value information is provided.
Severity Warning · Severity Error · Severity Error

The cooling device sensors listed monitor how well a fan is functioning. Cooling device messages provide status and warning information for fans in a particular chassis.
Description Fan sensor has failed Sensor location:
Cause A fan sensor in the specified system is not functioning. The sensor location, chassis location, previous state, and fan sensor value information is provided.
Description Fan sensor value unknown Sensor location:
Cause A fan sensor in the specified system could not obtain a reading. The sensor location, chassis location, previous state, and a nominal fan sensor value information is provided.
Description Fan sensor returned to a normal value Sensor location:
Cause A fan sensor reading on the specified system returned to a valid range after crossing a warning threshold. The sensor location, chassis location, previous state, and fan sensor value information is provided.
Description Fan sensor detected a warning value Sensor location:
Severity Error · Severity Error · Severity Information

Cause A fan sensor reading in the specified system exceeded a warning threshold. The sensor location, chassis location, previous state, and fan sensor value information is provided.
Description Fan sensor detected a failure value Sensor location:
Cause A fan sensor in the specified system detected the failure of one or more fans. The sensor location, chassis location, previous state, and fan sensor value information is provided.
Description Fan sensor detected a non-recoverable value Sensor location:
Cause A fan sensor detected an error from which it cannot recover. The sensor location, chassis location, previous state, and fan sensor value information is provided.
The voltage sensors listed monitor the number of volts across critical components. Voltage sensor messages provide status and warning information for voltage sensors in a particular chassis.
Description Voltage sensor has failed Sensor location:
If sensor type is not discrete:
Severity Warning · Severity Error · Severity Error

If sensor type is discrete:
Cause A voltage sensor in the specified system failed. The sensor location, chassis location, previous state, and voltage sensor value information is provided.
Description Voltage sensor value unknown Sensor location:
If sensor type is not discrete:
If sensor type is discrete:
Cause A voltage sensor in the specified system could not obtain a reading. The sensor location, chassis location, previous state, and a nominal voltage sensor value are provided.
Description Voltage sensor returned to a normal value Sensor location:
If sensor type is not discrete:
If sensor type is discrete:
Cause A voltage sensor in the specified system returned to a valid range after crossing a failure threshold. The sensor location, chassis location, previous state, and voltage sensor value information is provided.
Description Voltage sensor detected a warning value Sensor location:
Severity Error · Severity Warning · Severity Information

If sensor type is not discrete:
If sensor type is discrete:
Cause A voltage sensor in the specified system exceeded its warning threshold. The sensor location, chassis location, previous state, and voltage sensor value information is provided.
Description Voltage sensor detected a failure value Sensor location:
If sensor type is not discrete:
If sensor type is discrete:
Cause A voltage sensor in the specified system exceeded its failure threshold. The sensor location, chassis location, previous state, and voltage sensor value information is provided.
Description Voltage sensor detected a non-recoverable value Sensor location:
If sensor type is not discrete:
If sensor type is discrete:
Cause A voltage sensor in the specified system detected an error from which it cannot recover. The sensor location, chassis location, previous state, and voltage sensor value information is provided.
Severity Warning · Severity Error · Severity Error

The current sensors listed measure the amount of current (in amperes) that is traversing critical components. Current sensor messages provide status and warning information for current sensors in a particular chassis.
Description Current sensor has failed Sensor location:
If sensor type is not discrete:
If sensor type is discrete:
Cause A current sensor in the specified system failed. The sensor location, chassis location, previous state, and current sensor value are provided.
Description Current sensor value unknown Sensor location:
If sensor type is not discrete:
If sensor type is discrete:
Cause A current sensor in the specified system could not obtain a reading. The sensor location, chassis location, previous state, and a nominal current sensor value information is provided.
Description Current sensor returned to a normal value Sensor location:
Severity Error · Severity Warning

If sensor type is not discrete:
If sensor type is discrete:
Cause A current sensor in the specified system returned to a valid range after crossing a failure threshold. The sensor location, chassis location, previous state, and current sensor value information is provided.
Description Current sensor detected a warning value Sensor location:
If sensor type is not discrete:
If sensor type is discrete:
Cause A current sensor in the specified system exceeded its warning threshold. The sensor location, chassis location, previous state, and current sensor value are provided.
Description Current sensor detected a failure value Sensor location:
If sensor type is not discrete:
If sensor type is discrete:
Severity Information · Severity Warning · Severity Error

Cause A current sensor in the specified system exceeded its failure threshold. The sensor location, chassis location, previous state, and current sensor value are provided.
Description Current sensor detected a non-recoverable value Sensor location:
If sensor type is not discrete:
If sensor type is discrete:
Cause A current sensor in the specified system detected an error from which it cannot recover. The sensor location, chassis location, previous state, and current sensor value are provided.
The chassis intrusion messages listed are a security measure. Chassis intrusion means that someone is opening the cover to a system’s chassis. Alerts are sent to prevent unauthorized removal of parts from a chassis.
Description Chassis intrusion sensor value unknown Sensor location:
Cause A chassis intrusion sensor in the specified system could not obtain a reading. The sensor location, chassis location, previous state, and chassis intrusion state are provided.
Description Chassis intrusion returned to normal Sensor location:
Severity Error · Severity Warning

Cause A chassis intrusion sensor in the specified system detected that a cover was opened while the system was operating but has since been replaced. The sensor location, chassis location, previous state, and chassis intrusion state information is provided.
Description Chassis intrusion detected Sensor location:
Cause A chassis intrusion sensor in the specified system detected that the system cover was opened while the system was operating. The sensor location, chassis location, previous state, and chassis intrusion state information is provided.
Redundancy means that a system chassis has more than one of certain critical components. Fans and power supplies, for example, are so important for preventing damage or disruption of a computer system that a chassis may have “extra” fans or power supplies installed. Redundancy allows a second or nth fan to keep the chassis components at a safe temperature when the primary fan has failed. Redundancy is normal when the intended number of critical components are operating. Redundancy is degraded when a component fails but others are still operating. Redundancy is lost when the number of components functioning falls below the redundancy threshold. Lists the redundancy unit messages.
The number of devices required for full redundancy is provided as part of the message, when applicable, for the redundancy unit and the platform. For details on redundancy computation, see the respective platform documentation.
Description Redundancy sensor has failed Redundancy unit:
Cause A redundancy sensor in the specified system failed. The redundancy unit location, chassis location, previous redundancy state, and the number of devices required for full redundancy are provided.
Severity Information · Severity Critical · Severity Error

Description Redundancy sensor value unknown Redundancy unit:
Cause A redundancy sensor in the specified system could not obtain a reading. The redundancy unit location, chassis location, previous redundancy state, and the number of devices required for full redundancy are provided.
Description Redundancy not applicable Redundancy unit:
Cause A redundancy sensor in the specified system detected that a unit was not redundant. The redundancy location, chassis location, previous redundancy state, and the number of devices required for full redundancy information is provided.
Description Redundancy is offline Redundancy unit:
Cause A redundancy sensor in the specified system detected that a redundant unit is offline. The redundancy unit location, chassis location, previous redundancy state, and the number of devices required for full redundancy information is provided.
Description Redundancy regained Redundancy unit:
Cause A redundancy sensor in the specified system detected that a “lost” redundancy device has been reconnected or replaced; full redundancy is in effect. The

redundancy unit location, chassis location, previous redundancy state, and the number of devices required for full redundancy information is provided.
Description Redundancy degraded Redundancy unit:
Cause A redundancy sensor in the specified system detected that one of the components of the redundancy unit has failed but the unit is still redundant. The redundancy unit location, chassis location, previous redundancy state, and the number of devices required for full redundancy information is provided.
Description Redundancy lost Redundancy unit:
Cause A redundancy sensor in the specified system detected that one of the components in the redundant unit has been disconnected, has failed, or is not present. The redundancy unit location, chassis location, previous redundancy state, and the number of devices required for full redundancy are provided.
The power supply sensors monitor how well a power supply is functioning. The power supply messages listed provides status and warning information for power supplies present in a particular chassis.
Description Power supply sensor value unknown Sensor Location:
If in configuration error state:
Configuration error type:
Severity Warning · Severity Error · Severity Warning

Cause A power supply sensor in the specified system could not obtain a reading. The sensor location, chassis location, previous state, power supply type, additional power supply status, and configuration error type information are provided.
Description Power supply returned to normal Sensor Location:
If in configuration error state:
Configuration error type:
Cause A power supply has been reconnected or replaced. The sensor location, chassis location, previous state, power supply type, additional power supply status, and configuration error type information are provided.
Description Power supply detected a warning Sensor Location:
If in configuration error state:
Configuration error type:
Cause A power supply sensor reading in the specified system exceeded a user-definable warning threshold. The sensor location, chassis location, previous state, power supply type, additional power supply status, and configuration error type information are provided.
Description Power supply detected a failure Sensor Location:
Severity Information · Severity Warning

If in configuration error state:
Configuration error type:
Cause A power supply has been disconnected or has failed. The sensor location, chassis location, previous state, power supply type, additional power supply status, and configuration error type information are provided.
The memory device messages listed provides status and warning information for memory modules present in a particular system. Memory devices determine health status by monitoring the ECC memory correction rate and the type of memory events that have occurred.
Description Memory device status is
Cause Memory device monitoring has been disabled. The memory module may not be correctly seated, wrongly configured, or has failed.
Description Memory device status is
Cause Memory device status is unknown. The memory module may not be correctly seated, wrongly configured, or has failed.
Description Memory device status is

Cause Memory device status is normal. The memory device identified in the message has returned to a normal state.
Description Memory device status is
Cause A memory device correction rate exceeded an acceptable value. The memory device status and possible memory module event cause information is provided.
Description Memory device status is
Cause A memory device correction rate exceeded an acceptable value, a memory spare bank was activated, or a multi-bit ECC error occurred. The system continues to function normally (except for a multi-bit error). Replace the memory module identified in the message during the system’s next scheduled maintenance. Clear the memory error on multi-bit ECC error. The memory device status and possible memory module event cause information is provided.
Description Memory device status is
Cause Memory device status is nonrecoverable. The memory module failed because of an irrecoverable error.
The hardware logs provide hardware status messages to systems management software. On certain systems, the hardware log is implemented as a circular queue. When the log becomes full, the oldest status messages are overwritten when new status messages are logged. On some systems, the log is not circular. On these systems, when the log becomes full, subsequent hardware status messages are lost. Hardware log sensor messages listed provides status and warning information about the noncircular logs that may fill up, resulting in lost status messages.
Severity Warning · Severity Error · Severity Informational

Description Log monitoring has been disabled
Cause A hardware log sensor in the specified system is disabled. The log type information is provided.
Description Log status is unknown
Cause A hardware log sensor in the specified system could not obtain a reading. The log type information is provided.
Description Log size is no longer near or at capacity
Cause The hardware log on the specified system is no longer near or at its capacity, usually as the result of clearing the log. The log type information is provided.
Description Log size is near capacity
Cause The size of a hardware log on the specified system is near or at the capacity of the hardware log. The log type information is provided.
Description Log status is full
Cause The size of a hardware log on the specified system is full. The log type information is provided.

Description Log sensor has failed
Cause A hardware log sensor in the specified system failed. The hardware log status cannot be monitored. The log type information is provided.
The processor sensors monitor how well a processor is functioning. Processor messages listed provides status and warning information for processors in a particular chassis.
Description Processor sensor value unknown Sensor Location:
Cause A processor sensor in the specified system could not obtain a reading. The sensor location, chassis location, previous state and processor sensor status information is provided.
Description Processor sensor returned to a normal value Sensor Location:
Cause A processor sensor in the specified system transitioned back to a normal state. The sensor location, chassis location, previous state and processor sensor status are provided.
Description Processor sensor detected a warning value Sensor Location:
Severity Error · Severity Warning · Severity Information

Cause A processor sensor in the specified system is in a throttled state. The sensor location, chassis location, previous state and processor sensor status information is provided.
Description Processor sensor detected a failure value Sensor Location:
Cause A processor sensor in the specified system is disabled, has a configuration error, or experienced a thermal trip. The sensor location, chassis location, previous state and processor sensor status are provided.
The pluggable device messages listed provides status and error information when some devices, such as memory cards, are added or removed.
Description Device plug event type unknown Device location:
Cause A pluggable device event message of unknown type was received. The device location, chassis location, and additional event details, if available, are provided.
Description Device added to system Device location:

Cause A device was added in the specified system. The device location, chassis location, and additional event details, if available, are provided.
Description Device removed from system Device location:
Cause A device was removed from the specified system. The device location, chassis location, and additional event details, if available, are provided.
Description Device configuration error detected Device location:
Cause A configuration error was detected for a pluggable device in the specified system. The device may have been added to the system incorrectly.
The battery sensors monitor how well a battery is functioning. The battery messages listed provides status and warning information for batteries in a particular chassis.
Description Battery sensor has failed Sensor location:
Cause A battery sensor in the specified system is not functioning. The sensor location, chassis location, previous state, and battery sensor status information is provided.
Description Battery sensor value unknown Sensor location:
Severity Information · Severity Error · Severity Critical/ Failure/Error

Cause A battery sensor in the specified system could not retrieve a reading. The sensor location, chassis location, previous state, and battery sensor status information is provided.
Description Battery sensor returned to a normal value Sensor location:
Cause A battery sensor in the specified system detected that a battery transitioned back to a normal state. The sensor location, chassis location, previous state, and battery sensor status information is provided.
Description Battery sensor detected a warning value Sensor location:
Cause A battery sensor in the specified system detected that a battery is in a predictive failure state. The sensor location, chassis location, previous state, and battery sensor status information is provided.
Description Battery sensor detected a failure value Sensor location:

Cause A battery sensor in the specified system detected that a battery has failed. The sensor location, chassis location, previous state, and battery sensor status information is provided.
Description Battery sensor detected a non-recoverable value Sensor location:
Cause A battery sensor in the specified system could not retrieve a value. The sensor location, chassis location, previous state, and battery sensor status information is provided.
The SD card device sensors monitor instrumented SD card devices in the system. The messages provide the status and error information for SD card devices present in a chassis.
Description SD card device sensor has failed Sensor location:
Cause An SD card device sensor in the specified system failed. The sensor location, chassis location, previous state, and SD card device type information is provided. The SD card state is provided if an SD card is present in the SD card device.
Description SD card device sensor value unknown Sensor location:
Severity Error · Severity Error

Cause An SD card device sensor in the specified system could not obtain a reading. The sensor location, chassis location, previous state, and SD card device type information is provided. The SD card state is provided if an SD card is present in the SD card device.
Description SD card device returned to normal Sensor location:
Cause An SD card device sensor in the specified system detected that an SD card transitioned back to a normal state. The sensor location, chassis location, previous state, and SD card device type information is provided. The SD card state is provided if an SD card is present in the SD card device.
Description SD card device detected a warning Sensor location:
Cause An SD card device sensor in the specified system detected a warning condition. The sensor location, chassis location, previous state, and SD card device type information is provided. The SD card state is provided if an SD card is present in the SD card device.
Description SD card device detected a failure Sensor location:
Severity Information · Severity Information · Severity Warning

Cause An SD card device sensor in the specified system detected an error. The sensor location, chassis location, previous state, and SD card device type information is provided. The SD card state is provided if an SD card is present in the SD card device.
Description SD card device sensor detected a non-recoverable value Sensor location:
Cause An SD card device sensor in the specified system detected an error from which it cannot recover. The sensor location, chassis location, previous state, and SD card device type information is provided. The SD card state is provided if an SD card is present in the SD card device.
The Alerts sent by M1000e Chassis Management Controller (CMC) are organized by severity. That is, the event ID of the CMC trap indicates the severity (informational, warning, critical, or non-recoverable) of the alert. Each CMC alert includes the originating system name, location, and event message text. The alert message text matches the corresponding Chassis Event Log message text that is logged by the sending CMC for that event.
Description CMC generated a test trap.
Cause A user-initiated test trap was issued, through the CMC GUI or RACADM CLI.
Description CMC reported a return-to-normal or informational event.
Cause CMC informational event, as described in the drsCAMessage variable binding supplied with the alert.

Description CMC reported a warning.
Cause CMC warning event, as described in the drsCAMessage variable supplied with the alert.
Description CMC reported a critical event.
Cause CMC critical event, as described in the drsCAMessage variable binding supplied with the alert.
Description CMC reported a non-recoverable event.
Cause CMC non-recoverable event, as described in the drsCAMessage variable binding supplied with the alert.
Severity Warning · Severity Critical · Severity Non-Recoverable

The Server Administrator Storage Management’s alert or event management features let you monitor the health of storage resources such as controllers, enclosures, physical disks, and virtual disks.
The Storage Management Service performs alert monitoring and logging. By default, the Storage Management service starts when the managed system starts up. If you stop the Storage Management Service, then alert monitoring and logging stops. Alert monitoring does the following:
See the Server Administrator Storage Management Online Help for updated information.
When you view an alert in the Server Administrator alert log, the alert identifies the specific components such as the controller name or the virtual disk name to which the alert applies. In an actual operating environment, a storage system can have many combinations of controllers and disks as well as user- defined names for virtual disks and other components. Each environment is unique in its storage configuration and user-defined names. To receive an accurate alert message, that the Storage Management service must be able to insert the environment-specific names of storage components into an alert message.
This environment-specific information is inserted after the alert message text as shown for alert 2127.
For other alerts, the alert message text is constructed from information passed directly from the controller (or another storage component) to the alert log. In these cases, the variable information is represented with a percent symbol in the Storage Management documentation. An example of such an alert is shown for alert 2334.

Table 3. Alert Message Format
Alert ID Message Text Displayed in the Storage Management Service Documentation
Message Text Displayed in the Alert Log with Variable Information Supplied
2127 Background Initialization started Background Initialization started: Virtual Disk 3 (Virtual Disk 3) Controller 1 (PERC 5/E Adapter)
2334 Controller event log % Controller event log: Current capacity of the battery is above threshold : Controller 1 (PERC 5/E Adapter)
The variables required to complete the message vary depending on the type of storage object and whether the storage object is in a SCSI or SAS configuration. The following table identifies the possible variables used to identify each storage object.
Table 4. Message Format with Variables for Each Storage Object
Storage Object Message Variables
Controller Message Format: Controller A (Name) Message Format: Controller A For example, 2326 A foreign configuration has been detected: Controller 1 (PERC 5/E Adapter)
Battery Message Format: Battery X Controller A For example, 2174 The controller battery has been removed: Battery 0 Controller 1
SCSI Physical Disk Message Format: Physical Disk X:Y Controller A, Connector B For example, 2049 Physical disk removed: Physical Disk 0:14 Controller 1, Connector 0
SAS Physical Disk Message Format: Physical Disk X:Y:Z Controller A, Connector B For example, 2049 Physical disk removed: Physical Disk 0:0:14 Controller 1, Connector 0
Virtual Disk Message Format: Virtual Disk X (Name) Controller A (Name) Message Format: Virtual Disk X Controller A For example, 2057 Virtual disk degraded: Virtual Disk 11 (Virtual Disk 11) Controller 1 (PERC 5/E Adapter)
Enclosure Message Format: Enclosure X:Y Controller A, Connector B For example, 2112 Enclosure shutdown: Enclosure 0:2 Controller 1, Connector 0

Storage Object Message Variables
where "C" is the SCSI ID number of the enclosure management module (EMM) managing the power supply. For example, 2122 Redundancy degraded: Power Supply 1, Controller 1, Connector 0, Target ID 6
SAS Power Supply Message Format: Power Supply X Controller A, Connector B, Enclosure C For example, 2312 A power supply in the enclosure has an AC failure: Power Supply 1, Controller 1, Connector 0, Enclosure 2
C where C is the SCSI ID number of the EMM managing the temperature probe. For example, 2101 Temperature dropped below the minimum warning threshold: Temperature Probe 1, Controller 1, Connector 0, Target ID 6
SAS Temperature Probe Message Format: Temperature Probe X Controller A, Connector B, Enclosure C For example, 2101 Temperature dropped below the minimum warning threshold: Temperature Probe 1, Controller 1, Connector 0, Enclosure 2
SCSI Fan Message Format: Fan X Controller A, Connector B, Target ID C where C is the SCSI ID number of the EMM managing the fan. For example, 2121 Device returned to normal: Fan 1, Controller 1, Connector 0, Target ID 6
SAS Fan Message Format: Fan X Controller A, Connector B, Enclosure C For example, 2121 Device returned to normal: Fan 1, Controller 1, Connector 0, Enclosure 2
SCSI EMM Message Format: EMM X Controller A, Connector B, Target ID C where C is the SCSI ID number of the EMM. For example, 2121 Device returned to normal: EMM 1, Controller 1, Connector 0, Target ID 6
SAS EMM Message Format: EMM X Controller A, Connector B, Enclosure C For example, 2121 Device returned to normal: EMM 1, Controller 1, Connector 0, Enclosure 2
The following sections describe alerts generated by the RAID or SCSI controllers supported by Storage Management. The alerts are displayed in the Server Administrator Alert tab or through Windows Event Viewer. These alerts can also be forwarded as SNMP traps to other applications.
SNMP traps are generated for the alerts listed in the following sections. These traps are included in the Server Administrator Storage Management, management information base (MIB). The SNMP traps for these alerts use all of the SNMP trap variables. For more information on SNMP support and the MIB, see the SNMP Reference Guide.
To locate an alert, scroll through the following table to find the alert number displayed on the Server Administrator Alert tab or search this file for the alert message text or number. See Understanding Event Messages for more information on severity levels.
For more information regarding alert descriptions and the appropriate corrective actions, see the online help.

Description Device failed.
Severity Critical / Failure / Error
Cause: A storage component such as a physical disk or an enclosure has failed. The failed component may have been identified by the controller while performing a task such as a rescan or a check consistency.
Action: Replace the failed component. You can identify which disk has failed by locating the disk that has a red “X” for its status. Perform a rescan after replacing the failed component.
754, 804, 854, 904, 954, 1004, 1054, 1104, 1154, 1204
Description Physical disk removed.
Severity Warning / Non-critical
Cause: A physical disk has been removed from the disk group. This alert can also be caused by loose or defective cables or by problems with the enclosure.
Action: If a physical disk was removed from the disk group, either replace the disk or restore the original disk. On some controllers, a removed disk has a red X for its status. On other controllers, a removed disk may have an Offline status or is not displayed on the user interface. Perform a rescan after replacing or restoring the disk. If a disk has not been removed from the disk group, then check for problems with the cables. See the online help for more information on checking the cables. Ensure that the enclosure is powered on. If the problem persists, check the enclosure documentation for further diagnostic information.
Description Physical disk offline.
Severity Warning / Non-critical

Cause: A physical disk in the disk group is offline. The user may have manually put the physical disk offline.
Action: Perform a rescan. You can also select the offline disk and perform a Make Online operation.
Description Physical disk degraded.
Severity Warning / Non-critical
Cause: A physical disk has reported an error condition and may be degraded. The physical disk may have reported the error condition in response to a SMART Trip (Predictive Failure).
Action: Replace the degraded physical disk. You can identify which disk is degraded by locating the disk that has a Yellow Triangle for its status. Perform a rescan after replacing the disk.
Description Physical disk inserted.
Cause: This alert is for informational purposes.

Description Virtual disk created.
Cause: This alert is for informational purposes.
Description Virtual disk deleted.
Cause: A virtual disk has been deleted. Performing a Reset Configuration may detect that a virtual disk has been deleted.
Description Virtual disk configuration changed.
Cause: This alert is for informational purposes.
Severity Informational

Description Virtual disk failed.
Severity Critical / Failure / Error
Cause: One or more physical disks included in the virtual disk have failed. If the virtual disk is non-redundant (does not use mirrored or parity data), then the failure of a single physical disk can cause the virtual disk to fail. If the virtual disk is redundant, then more physical disks have failed than can be rebuilt using mirrored or parity information.
Action: Create a new virtual disk and restore from a backup.
Description Virtual disk degraded.
Severity Warning / Non-critical
Cause 1: This alert message occurs when a physical disk included in a redundant virtual disk fails. Because the virtual disk is redundant (uses mirrored or parity information) and only one physical disk has failed, the virtual disk can be rebuilt.
Action 1: Replace the failed drive. Rebuild of the virtual disk starts automatically.
If you put the drive in a different slot, you need to assign it as a hot spare for the rebuild to start automatically.
Cause 2: A physical disk in the disk group has been removed.
Action 2: If a physical disk was removed from the disk group, either replace the disk or restore the original disk. You can identify which disk has been removed by locating the disk that has a red “X” for its status. Perform a rescan after replacing the disk.

Description Virtual disk check consistency started.
Cause: This alert is for informational purposes.
Description Virtual disk format started.
Cause: This alert is for informational purposes.
Description Copy of data started from physical disk % 2 to physical disk % 1.
Cause: This alert is for informational purposes.

Description Virtual disk initialization started.
Cause: This alert is for informational purposes.
Description Physical disk initialization started.
Cause: This alert is for informational purposes.
Description Virtual disk reconfiguration started.
Cause: This alert is for informational purposes.

Description Virtual disk rebuild started.
Cause: This alert is for informational purposes.
Description Physical disk rebuild started.
Cause: This alert is for informational purposes.
Description Virtual disk check consistency cancelled.
Cause: The check consistency operation was cancelled because a physical disk in the array has failed or because a user cancelled the check consistency operation.
Action: If the physical disk failed, then replace the physical disk. You can identify which disk failed by locating the disk that has a red “X” for its status. Perform a rescan after replacing the disk. The consistency check can take a long time. The time it takes depends on the size of the physical disk or the virtual disk.

Description Virtual disk initialization cancelled.
Cause: The virtual disk initialization cancelled because a physical disk included in the virtual disk has failed or because a user cancelled the virtual disk initialization.
Action: If a physical disk failed, then replace the physical disk. You can identify which disk has failed by locating the disk that has a red “X” for its status. Perform a rescan after replacing the disk. Restart the format physical disk operation. Restart the virtual disk initialization.
Description Physical disk rebuild cancelled.
Cause: The user has cancelled the rebuild operation.
Action: Restart the rebuild operation.
Description Copy of data completed from physical disk % 2 to physical disk % 1.
Cause: This alert is provided for informational purposes.

Description Virtual disk Check Consistency failed.
Severity Critical / Failure / Error
Cause: AA physical disk included in the virtual disk failed or there is an error in the parity information. A failed physical disk can cause errors in parity information.
Action: Replace the failed physical disk. You can identify which disk has failed by locating the disk that has a red “X” for its status. Rebuild the physical disk. When finished, restart the check consistency operation.
Description Virtual disk format failed.
Severity Critical / Failure / Error
Cause: A physical disk included in the virtual disk failed.
Action: Replace the failed physical disk. You can identify which physical disk has failed by locating the disk that has a red X for its status. Rebuild the physical disk. When finished, restart the virtual disk format operation.
Description Virtual disk initialization failed.
Severity Critical / Failure / Error
Cause: A physical disk included in the virtual disk has failed or a user has cancelled the initialization.

Description Physical disk initialization failed.
Severity Critical / Failure / Error
Cause: The physical disk has failed or is not functioning.
Action: Replace the failed or non-functional disk. You can identify a disk that has failed by locating the disk that has a red “X” for its status. Restart the initialization.
Description Virtual disk reconfiguration failed.
Severity Critical / Failure / Error
Hardware RAID:
Cause: A physical disk included in the virtual disk has failed or is not functioning. A user may also have cancelled the reconfiguration.
Action: Replace the failed or non-functional disk. You can identify a disk that has failed by locating the disk that displays a red X in the status field.
If the physical disk is part of a redundant array, then rebuild the physical disk. When finished, restart the reconfiguration.
Software RAID:

Description Virtual disk rebuild failed.
Severity Critical / Failure / Error
Cause: A physical disk included in the virtual disk has failed or is not functioning. A user may also have cancelled the rebuild.
Action: Replace the failed or non-functional disk. You can identify a disk that has failed by locating the disk that has a red X for its status. Restart the virtual disk rebuild.
Description Physical disk rebuild failed.
Severity Critical / Failure / Error
Cause: A physical disk included in the virtual disk has failed or is not functioning. A user may also have cancelled the rebuild.
Action: Replace the failed or non-functional disk. You can identify a disk that has failed by locating the disk that has a red X for its status. Rebuild the virtual disk rebuild.
Description Virtual disk check consistency completed.
Cause: This alert is for informational purposes.

Clear Alert Number: Alert 2085 is a clear alert for alert 2058.
Description Virtual disk format completed.
Cause: This alert is for informational purposes.
Clear Alert Number: Alert 2086 is a clear alert for alert 2059.
Description Copy of data resumed from physical disk % 2 to physical disk % 1.
Cause: This alert is for informational purposes.
Description Virtual disk initialization completed.
Cause: This alert is for informational purposes.
Clear Alert Number: Alert 2088 is a clear alert for alerts 2061 and 2136.

Description Physical disk initialization completed.
Cause: This alert is for informational purposes.
Clear Alert Number: Alert 2089 is a clear alert for alert 2062.
Description Virtual disk reconfiguration completed
Cause: This alert is for informational purposes.
Clear Alert Number: Alert 2090 is a clear alert for alert 2063.
Description Virtual disk rebuild completed.
Cause: This alert is for informational purposes.
Clear Alert Number: Alert 2091 is a clear alert for alert 2064.

Description Physical disk rebuild completed.
Cause: This alert is for informational purposes.
Clear Alert Number: Alert 2092 is a clear alert for alert 2065.
Description Predictive Failure reported.
Severity Warning / Non-critical
Cause: The physical disk is predicted to fail. Many physical disks contain Self Monitoring Analysis and Reporting Technology (SMART). When enabled, SMART monitors the health of the disk based on indications such as the number of write operations that have been performed on the disk.
Action: Replace the physical disk. Even though the disk may not have failed yet, it is strongly recommended that you replace the disk.
If this disk is part of a redundant virtual disk, perform the Offline task on the disk; replace the disk; the rebuild starts automatically.
If this disk is a hot spare, then unassign the hot spare; perform the Prepare to Remove task on the disk; replace the disk; and assign the new disk as a hot spare.
Description SCSI sense data %1.

Cause: A SCSI device experienced an error, but may have recovered.
Description Global hot spare assigned.
Cause: A user has assigned a physical disk as a global hot spare. This alert is for informational purposes.
Description Global hot spare unassigned.
Cause: A physical disk that was assigned as a hot spare has been unassigned and is no longer functioning as a hot spare. The physical disk may have been unassigned by a user or automatically unassigned by Storage Management. Storage Management unassigns hot spares that have been used to rebuild data. Once data is rebuilt, the hot spare becomes a member of the virtual disk and is no longer assigned as a hot spare. You need to assign a new hot spare to maintain data protection in this situation. On the CERC SATA1.5/6 ch, and CERC SATA1.5/2s controllers, if you use another application such as the BIOS to include a hot spare in a virtual disk, then Storage Management unassigns the physical disk as a hot spare.
Action: Although this alert is provided for informational purposes, you may need to assign a new hot spare to the virtual disk.
751, 851, 901

Description Temperature exceeded the maximum warning threshold.
Severity Warning / Non-critical
Cause: The physical disk enclosure is too hot. A variety of factors can cause the excessive temperature. For example, a fan may have failed, the thermostat may be set too high, or the room temperature may be too hot.
Action: Check for factors that may cause overheating. For example, verify that the enclosure fan is working. You should also check the thermostat settings and examine whether the enclosure is located near a heat source. Make sure the enclosure has enough ventilation and that the room temperature is not too hot. See the physical disk enclosure documentation for more diagnostic information.
Description Temperature exceeded the maximum warning threshold.
Severity Warning / Non-critical
Cause: The physical disk enclosure is too cool.
Action: Check if the thermostat setting is too low and if the room temperature is too cool.
Description Temperature exceeded the maximum failure threshold.
Severity Critical / Failure / Error
Cause: The physical disk enclosure is too hot. A variety of factors can cause the excessive temperature. For example, a fan may have failed, the thermostat may be set too high, or the room temperature may be too hot.
Action: Check for factors that may cause overheating. For example, verify that the enclosure fan is working. You should also check the thermostat settings and

examine whether the enclosure is located near a heat source. Make sure the enclosure has enough ventilation and that the room temperature is not too hot. See the physical disk enclosure documentation for more diagnostic information.
Description Temperature dropped below the minimum failure threshold.
Severity Critical / Failure / Error
Cause: The physical disk enclosure is too cool.
Action: Check if the thermostat setting is too low and if the room temperature is too cool.
Description Controller battery is reconditioning.
Cause: This alert is for informational purposes.
Description Controller battery recondition is completed.

Cause: This alert is for informational purposes.
Clear Alert Number: Alert 2105 is a clear alert for alert 2104.
Description SMART FPT exceeded.
Severity Warning / Non-critical
Cause: A disk on the specified controller has received a SMART alert (predictive failure) indicating that the disk is likely to fail in the near future.
Action: Replace the disk that has received the SMART alert. If the physical disk is a member of a non-redundant virtual disk, then back up the data before replacing the disk.
Description SMART configuration change.
Severity Critical / Failure / Error
Cause: A disk has received a SMART alert (predictive failure) after a configuration change. The disk is likely to fail in the near future.
Action: Replace the disk that has received the SMART alert. If the physical disk is a member of a non-redundant virtual disk, then back up the data before replacing the disk.

Description SMART warning.
Severity Warning / Non-critical
Cause: A disk has received a SMART alert (predictive failure). The disk is likely to fail in the near future.
Action: Replace the disk that has received the SMART alert. If the physical disk is a member of a non-redundant virtual disk, then back up the data before replacing the disk.
Description SMART warning temperature.
Severity Warning / Non-critical
Cause: A disk has reached an unacceptable temperature and received a SMART alert (predictive failure). The disk is likely to fail in the near future.
Action 1: Determine why the physical disk has reached an unacceptable temperature. A variety of factors can cause the excessive temperature. For example, a fan may have failed, the thermostat may be set too high, or the room temperature may be too hot or cold. Verify that the fans in the server or enclosure are working. If the physical disk is in an enclosure, you should check the thermostat settings and examine whether the enclosure is located near a heat source.
Make sure the enclosure has enough ventilation and that the room temperature is not too hot. See the physical disk enclosure documentation for more diagnostic information.
Action 2 : If you cannot identify why the disk has reached an unacceptable temperature, then replace the disk. If the physical disk is a member of a non- redundant virtual disk, then back up the data before replacing the disk.

Description SMART warning degraded.
Severity Warning / Non-critical
Cause: A disk is degraded and has received a SMART alert (predictive failure). The disk is likely to fail in the near future.
Action: Replace the disk that has received the SMART alert. If the physical disk is a member of a nonredundant virtual disk, then back up the data before replacing the disk.
Description Failure prediction threshold exceeded due to test.
Severity Warning / Non-critical
Cause: A disk has received a SMART alert (predictive failure) due to test conditions.
Description Enclosure was shut down.
Severity Critical / Failure / Error

Cause: The physical disk enclosure is either hotter or cooler than the maximum or minimum allowable temperature range.
Action: Check for factors that may cause overheating or excessive cooling. For example, verify that the enclosure fan is working. You should also check the thermostat settings and examine whether the enclosure is located near a heat source. Make sure the enclosure has enough ventilation and that the room temperature is not too hot or too cold. See the enclosure documentation for more diagnostic information.
Description A consistency check on a virtual disk has been paused (suspended).
Cause: The check consistency operation on a virtual disk was paused by a user.
Action: To resume the check consistency operation, right-click the virtual disk in the tree view and select Resume Check Consistency.
Description A consistency check on a virtual disk has been resumed.
Cause: The check consistency operation on a virtual disk has resumed processing after being paused by a user. This alert is for informational purposes.
Clear Alert Number: Alert 2115 is a clear alert for alert 2114.

Description A virtual disk and its mirror have been split.
Cause: A user has caused a mirrored virtual disk to be split. When a virtual disk is mirrored, its data is copied to another virtual disk in order to maintain redundancy. After being split, both virtual disks retain a copy of the data although the mirror is no longer intact. The updates to the data are no longer copied to the mirror. This alert is for informational purposes.
Description A mirrored virtual disk has been unmirrored.
Cause: A user has caused a mirrored virtual disk to be unmirrored. When a virtual disk is mirrored, its data is copied to another virtual disk in order to maintain redundancy. After being unmirrored, the disk formerly used as the mirror returns to being a physical disk and becomes available for inclusion in another virtual disk. This alert is for informational purposes.
Description Change write policy.
Cause: A user has changed the write policy for a virtual disk. This alert is for informational purposes.

Description Enclosure firmware mismatch.
Severity Warning / Non-critical
Cause: The firmware on the EMM is not the same version. It is required that both modules have the same version of the firmware. This alert may be caused when a user attempts to insert an EMM module that has a different firmware version than an existing module.
Action: Download the same version of the firmware to both EMM modules.
Description Device returned to normal.
Cause: A device that was previously in an error state has returned to a normal state. For example, if an enclosure became too hot and subsequently cooled down, you may receive this alert. This alert is for informational purposes.
Clear Alert Number: Alert 2121 is a clear alert for alert 2048.
752,802, 852, 902, 952, 1002,1052, 1102, 1152, 1202
Description Redundancy degraded.
Severity Warning / Non-critical

Cause: One or more of the enclosure components has failed.
For example, a fan or power supply may have failed. Although the enclosure is currently operational, the failure of additional components could cause the enclosure to fail.
Action: Identify and replace the failed component. To identify the failed component, select the enclosure in the tree view and click the Health subtab. Any failed component is identified with a red X on the enclosure’s Health subtab. Alternatively, you can select the Storage object and click the Health subtab.
The controller status displayed on the Health subtab indicates whether a controller has a Failed or Degraded component.
See the enclosure documentation for information on replacing enclosure components and for other diagnostic information.
Description Redundancy lost.
Severity Warning / Non-critical
Cause: A virtual disk or an enclosure has lost data redundancy. In the case of a virtual disk, one or more physical disks included in the virtual disk have failed. Due to the failed physical disk or disks, the virtual disk is no longer maintaining redundant (mirrored or parity) data. The failure of an additional physical disk results in lost data. In the case of an enclosure, more than one enclosure component has failed. For example, the enclosure may have suffered the loss of all fans or all power supplies.
Action: Identify and replace the failed components. To identify the failed component, select the Storage object and click the Health subtab. The controller status displayed on the Health subtab indicates whether a controller has a Failed or Degraded component.
Click the controller that displays a Warning or Failed status. This action displays the controller Health subtab which displays the status of the individual controller components. Continue clicking the components with a Warning or Health status until you identify the failed component.
See the online help for more information. See the enclosure documentation for information on replacing enclosure components and for other diagnostic information.

Description Redundancy normal.
Cause: Data redundancy has been restored to a virtual disk or an enclosure that previously suffered a loss of redundancy. This alert is for informational purposes.
Clear Alert Number: Alert 2124 is a clear alert for alerts 2122 and 2123.
Description Controller cache preserved for missing or offline virtual disk.
Severity Warning / Non-critical
Cause: Virtual disk controller was disconnected, during I/O operation.
Action: Import foreign disks, if any. Check if the enclosure containing the virtual disk is disconnected from the controller.
Description SCSI sense sector reassign.
Severity Warning / Non-critical
Cause: A sector of the physical disk is corrupted and data cannot be maintained on this portion of the disk. This alert is for informational purposes.
Action: If the physical disk is part of a non-redundant virtual disk, then back up the data and replace the physical disk.

If the disk is part of a redundant virtual disk, then any data residing on the corrupt portion of the disk is reallocated elsewhere in the virtual disk.
Description Background initialization (BGI) started.
Cause: BGI of a virtual disk has started. This alert is for informational purposes.
Description BGI cancelled.
Cause: BGI of a virtual disk has been cancelled. A user or the firmware may have stopped BGI.
Description BGI failed.
Severity Critical / Failure / Error

Cause: BGI of a virtual disk has failed.
Description BGI completed.
Cause: BGI of a virtual disk has completed. This alert is for informational purposes.
Clear Alert Number: Alert 2130 is a clear alert for alert 2127.
Description Firmware version mismatch.
Severity Warning / Non-critical
Cause: The firmware on the controller is not a supported version.
Action: Install a supported version of the firmware. If you do not have a supported version of the firmware available, check with your support provider for information on how to obtain the most current firmware.
Description Driver version mismatch.
Severity Warning / Non-critical

Cause: The controller driver is not a supported version.
Action: Install a supported version of the driver. If you do not have a supported driver version available, you can check with your support provider for information on how to obtain the most current driver.
Description Array Manager is installed on the system.
Severity Warning / Non-critical
Cause: Storage Management has been installed on a system that has an Array Manager installation.
Action: Installing Storage Management and Array Manager on the same system is not a supported configuration. Uninstall either Storage Management or Array Manager.
Description Virtual disk initialization.
Cause: Virtual disk initialization is in progress. This alert is for informational purposes.

Description Communication time-out.
Severity Warning / Non-critical
Cause: The controller is unable to communicate with an enclosure. There are several reasons why communication may be lost. For example, there may be a bad or loose cable. An unusual amount of I/O may also interrupt communication with the enclosure. In addition, communication loss may be caused by software, hardware, or firmware problems, bad or failed power supplies, and enclosure shutdown.
When viewed in the alert log, the description for this event displays several variables. These variables are: controller and enclosure names, type of communication problem, return code, and SCSI status.
Action: Check for problems with the cables. See the online help for more information on checking the cables. You should also check to see if the enclosure has degraded or failed components. To do so, select the enclosure object in the tree view and click the Health subtab. The Health subtab displays the status of the enclosure components. Verify that the controller has supported driver and firmware versions installed and that the EMMs are each running the same version of supported firmware.
Description Enclosure alarm enabled.
Cause: A user has enabled the enclosure alarm. This alert is for informational purposes.

Description Enclosure alarm disabled.
Cause: A user has disabled the enclosure alarm.
Description Dead disk segments restored.
Cause: Disk space that was formerly “dead” or inaccessible to a redundant virtual disk has been restored. This alert is for informational purposes.
Description Physical disk dead segments removed.
Cause: Portions of the physical disk were formerly inaccessible. The disk space from these dead segments has been recovered and is now usable. Any data residing on these dead segments has been lost. This alert is for informational purposes.
Action: Check for factors that may cause overheating. For example, verify that the enclosure fan is working. You should also check the thermostat settings and examine whether the enclosure is located near a heat source. Make sure the enclosure has enough ventilation and that the room temperature is not too hot. See the physical disk enclosure documentation for more diagnostic information.

Description Controller rebuild rate has changed.
Cause: A user has changed the controller rebuild rate. This alert is for informational purposes.
Description Controller alarm enabled.
Cause: A user has enabled the controller alarm. This alert is for informational purposes.
Description Controller alarm disabled.
Cause: A user has disabled the controller alarm. This alert is for informational purposes.

Description Controller battery low.
Severity Warning / Non-critical
Cause: The controller battery charge is low.
Action: Recondition the battery. See the online help for more information.
Description Bad block replacement error.
Severity Warning / Non-critical
Cause: A portion of a physical disk is damaged.
Action: See the Server Administrator Storage Management online help for more information.
Description Bad block sense error.
Severity Warning / Non-critical
Cause: A portion of a physical disk is damaged.
Action: See the Server Administrator Storage Management online help for more information.

Description Bad block medium error.
Severity Warning / Non-critical
Cause: A portion of a physical disk is damaged.
Action: See the Server Administrator Storage Management online help for more information.
Description Bad block extended sense error.
Severity Warning / Non-critical
Cause: A portion of a physical disk is damaged.
Action: See the Server Administrator Storage Management online help for more information.
Description Bad block extended medium error.
Severity Warning / Non-critical
Cause: A portion of a physical disk is damaged.
Action: See the Server Administrator Storage Management online help for more information.

Description Enclosure asset tag changed
Cause: A user has changed the enclosure asset tag. This alert is for informational purposes.
Description Enclosure asset name changed.
Cause: A user has changed the enclosure asset name. This alert is for informational purposes.
Description Enclosure service tag changed.
Cause: An enclosure service tag was changed. In most circumstances, this service tag should only be changed by your service provider.
Action: Ensure that the tag was changed under authorized circumstances.

Description Maximum temperature probe warning threshold value changed.
Cause: A user has changed the value for the maximum temperature probe warning threshold. This alert is for informational purposes.
Description Minimum temperature probe warning threshold value changed.
Cause: A user has changed the value for the minimum temperature probe warning threshold. This alert is for informational purposes.
Description Controller alarm has been tested.
Cause: The controller alarm test has run successfully. This alert is for informational purposes.

Description Controller configuration has been reset.
Cause: A user has reset the controller configuration. See the online help for more information. This alert is for informational purposes.
Description Physical disk online.
Cause: An offline physical disk has been made online. This alert is for informational purposes.
Clear Alert Number: Alert 2158 is a clear alert for alert 2050.
Description Virtual disk renamed.
Cause: A user has renamed a virtual disk.
When renaming a virtual disk on a PERC 4/SC, 4/DC, 4e/DC, 4/Di, CERC ATA100/4ch, PERC 5/E, PERC 5/i or SAS 5/iR controller, this alert displays the new virtual disk name.
On the PERC 4/SC, 4/DC, 4e/DC, 4/Di, 4/IM, 4e/Si, 4e/Di, and CERC ATA 100/4ch controllers, this alert displays the original virtual disk name. This alert is for informational purposes.

Description Dedicated hot spare assigned.
Cause: A user has assigned a physical disk as a dedicated hot spare to a virtual disk. This alert is provided for informational purposes.
Description Dedicated hot spare unassigned.
Cause: A physical disk that was assigned as a hot spare has been unassigned and is no longer functioning as a hot spare. The physical disk may have been unassigned by a user or automatically unassigned by Storage Management. Storage Management unassigns hot spares that have been used to rebuild data. Once data is rebuilt onto the hot spare, the hot spare becomes a member of the virtual disk and is no longer assigned as a hot spare. You need to assign a new hot spare to maintain data protection in this situation. On the CERC SATA1.5/6ch, and CERC SATA1.5/2s controllers, if you use another application such as the BIOS to include a hot spare in a virtual disk, then Storage Management unassigns the physical disk as a hot spare.
Action: Although this alert is provided for informational purposes, you may need to assign a new hot spare to the virtual disk.

Description Communication regained.
Cause: Communication with an enclosure has been restored. This alert is for informational purposes.
Clear Alert Number: Alert 2162 is a clear alert for alerts 2137 and 2292.
Description Rebuild completed with errors.
Cause: During a rebuild one or more blocks of data was not recoverable due to missing parity information. Some data loss may have occurred.
Action: Perform a check to verify the built array. Any files that are impacted should be restored from a backup. See the Storage Management online help for more information.
Description See the Readme file for a list of validated controller driver versions.
Cause: Storage Management is unable to determine whether the system has the minimum required versions of the RAID controller drivers. This alert is for informational purposes.
Action: See the Readme file for driver and firmware requirements. In particular, if Storage Management experiences performance problems, you should verify that you have the minimum supported versions of the drivers and firmware installed.

Description The RAID controller firmware and driver validation was not performed. The configuration file cannot be opened.
Severity Warning / Non-critical
Cause: Storage Management is unable to determine whether the system has the minimum required versions of the RAID controller firmware and drivers. This situation may occur for a variety of reasons. For example, the installation directory path to the configuration file may not be correct. The configuration file may also have been removed or renamed.
Description The RAID controller firmware and driver validation was not performed. The configuration file is out of date, missing the required information, or not properly formatted to complete the comparison.
Severity Warning / Non-critical
Cause: Storage Management is unable to determine whether the system has the minimum required versions of the RAID controller firmware and drivers. This situation has occurred because a configuration file is out of date, missing the required information, or not properly formatted to complete the comparison.
Action: Reinstall Storage Management.
Description The current kernel version and the non-RAID SCSI driver version are older than the minimum required levels. See readme.txt for a list of validated kernel and driver versions.

Severity Warning / Non-critical
Cause: The version of the kernel and the driver do not meet the minimum requirements. Storage Management may not be able to display the storage or perform storage management functions until you have updated the system to meet the minimum requirements.
Action: See the Readme file for a list of validated kernel and driver versions. Update the system to meet the minimum requirements and then reinstall Storage Management.
Description The non-RAID SCSI driver version is older than the minimum required level. See readme.txt for the validated driver version.
Severity Warning / Non-critical
Cause: The version of the driver does not meet the minimum requirements. Storage Management may not be able to display the storage or perform storage management functions until you have updated the system to meet the minimum requirements.
Action: See the Readme file for the validated driver version. Update the system to meet the minimum requirements and then reinstall Storage Management.
Description The controller battery needs to be replaced.
Severity Critical / Failure / Error
Cause: The controller battery cannot be recharged. The battery may be old or it may have been already recharged the maximum number of times. In addition, the battery charger may not be working.
Action: Replace the battery pack.

Description The controller battery charge level is normal.
Cause: This alert is for informational purposes.
Description The controller battery temperature is above normal.
Severity Warning / Non-critical
Cause: The battery may be recharging, the room temperature may be too hot, or the fan in the system may be degraded or failed.
Action: If this alert was generated due to a battery recharge, the situation is corrected when the recharge is complete. You should also check if the room temperature is normal and that the system components are functioning properly.
Description The controller battery temperature is normal.
Cause: This alert is for informational purposes.
Clear Alert Number: Alert 2172 is a clear alert for alert 2171.

Description Unsupported configuration detected. The SCSI rates of the enclosure management modules (EMMs) are not the same. EMM 0 % 1 EMM 1 % 2
Severity Warning / Non-critical
Cause: An unsupported configuration was detected.
Action: Replace one of the EMMs with the matching SCSI rate EMM.
Description The controller battery has been removed.
Severity Warning / Non-critical
Cause: The controller cannot communicate with the battery. The battery may be removed, or the contact point between the controller and the battery may be burnt or corroded.
Action: Replace the battery if it has been removed. If the contact point between the battery and the controller is burnt or corroded, you must replace either the battery or the controller, or both. See the hardware documentation for information on how to safely access, remove, and replace the battery.
Description The controller battery has been replaced.
Cause: This alert is for informational purposes.

Description The controller battery Learn cycle has started.
Cause: This alert is for informational purposes.
Description The controller battery Learn cycle has completed.
Cause: This alert is for informational purposes.
Clear Alert Number: Alert 2177 is a clear alert for alert 2176.
Description The controller battery Learn cycle has timed out.
Severity Warning / Non-critical
Cause: The controller battery must be fully charged before the Learn cycle can begin. The battery may be unable to maintain a full charge causing the Learn cycle to timeout. Additionally, the battery must be able to maintain cached data for a specified period of time in the event of a power loss. For example, some batteries maintain cached data for 24 hours. If the battery is unable to maintain cached data for the required period of time, then the Learn cycle timeout occurs.
Action: Replace the battery pack as the battery is unable to maintain a full charge.

Description The controller battery Learn cycle has been postponed.
Cause: This alert is for informational purposes.
Description The controller battery Learn cycle starts in % 1 days.
Cause: This alert is for informational purposes. The %1 indicates a substitution variable. The text for this substitution variable is displayed with the alert in the alert log and can vary depending on the situation.
Description The controller battery learn cycle starts in % 1 hours.
Cause: The % 1 indicates a substitution variable. The text for this substitution variable is displayed with the alert in the alert log and can vary depending on the situation. This alert is for informational purposes.

Description An invalid SAS configuration has been detected.
Severity Critical / Failure / Error
Cause: The controller and attached enclosures are not cabled correctly.
Action: See the hardware documentation for information on correct cabling configurations.
Description Replace Member Operation failed on physical disk % 1 from physical disk % 2.
Severity Critical / Failure / Error
Cause: The physical disk participating in the Replace Member Operation, operation has failed.
Description Physical disk Replace Member Operation cancelled.
Cause: User cancelled the Replace Member Operation.

Description Physical disk Replace Member Operation stopped for spare.
Severity Warning / Non-critical
Cause: This alert is provided for informational purposes.
Description The controller cache has been discarded.
Severity Warning / Non-critical
Cause: The controller has flushed the cache and any data in the cache has been lost. This may happen if the system has memory or battery problems that cause the controller to distrust the cache. Although user data may have been lost, this alert does not always indicate that relevant or user data has been lost.
Action: Verify that the battery and memory are functioning properly.
Description Single-bit ECC error limit exceeded on the controller DIMM.
Severity Warning / Non-critical
Cause: The system memory is malfunctioning.
Action: Contact technical support to replace the controller memory.

Description The controller write policy has been changed to Write Through.
Cause: The controller battery is unable to maintain cached data for the required period of time. For example, if the required period of time is 24 hours, the battery is unable to maintain cached data for 24 hours. It is normal to receive this alert during the battery Learn cycle as the Learn cycle discharges the battery before recharging it. When discharged, the battery cannot maintain cached data.
Action: Check the health of the battery. If the battery is weak, replace the battery pack.
Description The controller write policy has been changed to Write Back.
Cause: This alert is for informational purposes.
Description The controller has detected a hot-add of an enclosure.
Severity Warning

Cause: This alert is for informational purposes.
Description Multiple enclosures are attached to the controller. This is an unsupported configuration.
Severity Critical / Failure / Error
Cause: There are too many enclosures attached to the controller port. When the enclosure limit is exceeded, the controller loses contact with all enclosures attached to the port.
Action: Remove the last enclosure. You must remove the enclosure that has been added last and is causing the enclosure limit to exceed.
Description The virtual disk Check Consistency has made corrections and completed.
Cause: The virtual disk Check Consistency has identified errors and made corrections. For example, the Check Consistency may have encountered a bad disk block and remapped the disk block to restore data consistency. This alert is for informational purposes.
Action: None. As a precaution, monitor the alert log for other errors related to this virtual disk. If problems persist, contact Technical Support.
Severity Informational

Description The virtual disk reconfiguration has resumed.
Cause: This alert is for informational purposes.
Description The virtual disk Read policy has changed.
Cause: This alert is for informational purposes.
Description Dedicated hot spare assigned. Physical disk % 1
Cause: This alert is for informational purposes.

Description Dedicated hot spare unassigned. Physical disk % 1
Cause: This alert is for informational purposes.
Description Physical disk Replace Member Operation stopped for rebuild.
Cause: This alert is provided for informational purposes.
Description The physical disk is too small to be used for Replace member operation.
Cause: This alert is for informational purposes.
Severity Warning · Severity Warning

Description The virtual disk cache policy has changed.
Cause: User has provided invalid input for the chosen operation.
Description Replace Member Operation not possible as SAS/SATA is not supported in the same virtual disk.
Cause: This alert is for informational purposes.
Description A global hot spare failed.
Cause: The controller is not able to communicate with a disk that is assigned as a dedicated hot spare. The disk may have been removed. There may also be a bad or loose cable.
Action: Check if the disk is healthy and that it has not been removed. Check the cables. If necessary, replace the disk and reassign the hot spare.
Severity Informational · Severity Warning/ Non-critical · Severity Warning/ Non-critical

Description A global hot spare has been removed.
Cause: The controller is unable to communicate with a disk that is assigned as a global hot spare. The disk may have been removed. There may also be a bad or loose cable.
Action: Check if the disk is healthy and that it has not been removed. Check the cables. If necessary, replace the disk and reassign the hot spare.
Description A dedicated hot spare failed.
Cause: The controller is unable to communicate with a disk that is assigned as a dedicated hot spare. The disk may have failed or been removed. There may also be a bad or loose cable.
Action: Check if the disk is healthy and that it has not been removed. Check the cables. If necessary, replace the disk and reassign the hot spare.
Description A dedicated hot spare has been removed.
Cause: The controller is unable to communicate with a disk that is assigned as a dedicated hot spare. The disk may have been removed. There may also be a bad or loose cable.
Action: Check if the disk is healthy and that it has not been removed. Check the cables. If necessary, replace the disk and reassign the hot spare.
Severity Warning/ Non-critical

Description A dedicated hot spare has been automatically unassigned.
Cause: The hot spare is no longer required because the virtual disk it was assigned to has been deleted.
Description The only hot spare available is a SATA disk. SATA disks cannot replace SAS disks.
Severity Warning / Non-critical
Cause: The only physical disk available to be assigned as a hot spare is using SATA technology. The physical disks in the virtual disk are using SAS technology. Because of this difference in technology, the hot spare cannot rebuild data if one of the physical disks in the virtual disk fails.
Action: Add a SAS disk that is large enough to be used as the hot spare and assign it as a hot spare.
Description The only hot spare available is a SAS disk. SAS disks cannot replace SATA disks.
Severity Warning / Non-critical

Cause: The only physical disk available to be assigned as a hot spare is using SAS technology. The physical disks in the virtual disk are using SATA technology. Because of this difference in technology, the hot spare cannot rebuild data if one of the physical disks in the virtual disk fails.
Action: Add a SATA disk that is large enough to be used as the hot spare and assign the new disk as a hot spare.
Description Battery requires reconditioning. Initiate the battery learn cycle.
Severity Warning / Non-critical
Cause: Battery is in warn only mode and requires reconditioning.
Action: Initiate the battery learn cycle.
Description The physical disk is not supported.
Severity Warning / Non-critical
Cause: The physical disk may not have a supported version of the firmware or the disk may not be supported by your service provider.
Action: If the disk is supported, update the firmware to a supported version. If the disk is not supported by your service provider, replace the disk with one that is supported.

Description The controller battery temperature is above normal.
Cause: This alert is for informational purposes.
Description Recharge count maximum exceeded.
Severity Warning / Non-critical
Cause: The battery has been recharged more times than the battery recharge limit allows.
Action: Replace the battery pack.
Description Battery charge in progress.
Cause: This alert is for informational purposes.

Description Battery charge process interrupted.
Cause: This alert is for informational purposes.
Description The battery learn mode has changed to auto.
Cause: This alert is for informational purposes.
Description The battery learn mode has changed to warn.
Cause: This alert is for informational purposes.

Description None of the Controller Property are set.
Cause: This alert is for informational purposes.
Action: You should change at least one controller property and run the command again.
Description Abort Check Consistency on Error, Replace Member Operation, Auto Replace Member Operation on Predictive Failure and Loadbalance changed.
Cause: This alert is for informational purposes.
Action: Change at least one controller property and run the command again.
Description Replace Member Operation, Auto Replace Member Operation on Predictive Failure and Loadbalance changed.
Cause: This alert is for informational purposes.
Action: Change at least one controller property and run the command again.

Description Auto Replace Member Operation on Predictive Failure, Abort CC on Error and Loadbalance changed.
Cause: This alert is for informational purposes.
Action: Change at least one controller property and run the command again.
Description Loadbalance and Auto Replace Member Operation on Predictive Failure changed.
Cause: This alert is for informational purposes.
Action: Change at least one controller property and run the command again.
Description Abort Check Consistency on Error, Replace Member Operation and Loadbalance changed.
Cause: This alert is for informational purposes.
Action: Change at least one controller property and run the command again.

Description Replace Member Operation and Loadbalance changed.
Cause: This alert is for informational purposes.
Action: Change at least one controller property and run the command again.
Description Abort Check Consistency on Error and Load balance changed.
Cause: This alert is for informational purposes.
Action: Change at least one controller property and run the command again.
Description Load balance changed.
Cause: This alert is for informational purposes.
Action: Change at least one controller property and run the command again.

Description Abort Check Consistency on Error, Replace Member Operation and Auto Replace Member Operation on Predictive Failure changed.
Cause: This alert is for informational purposes.
Action: Change at least one controller property and run the command again.
Description Replace Member Operation and Auto Replace Member Operation on Predictive Failure changed.
Cause: This alert is for informational purposes.
Action: Change at least one controller property and run the command again.
Description Abort Check Consistency on Error and Auto Replace Member Operation on Predictive Failure changed.
Cause: This alert is for informational purposes.
Action: Change at least one controller property and run the command again.

Description Auto Replace Member Operation on Predictive Failure changed.
Cause: This alert is for informational purposes.
Action: Change at least one controller property and run the command again.
Description Replace Member Operation and Abort Check Consistency on Error changed.
Cause: This alert is for informational purposes.
Action: Change at least one controller property and run the command again.
Description The controller alarm is silenced.
Cause: This alert is for informational purposes.

Description The Background initialization (BGI) rate has changed.
Cause: This alert is for informational purposes.
Description The Patrol Read rate has changed.
Cause: This alert is for informational purposes.
Description The Check Consistency rate has changed.
Cause: This alert is for informational purposes.

Description Replace Member Operation modified.
Cause: This alert is for informational purposes.
Action: Change at least one controller property and run the command again.
Description Abort Check Consistency on Error modified.
Cause: This alert is for informational purposes.
Action: Change at least one controller property and run the command again.
Description The controller debug log file has been exported.
Cause: The user has attempted to export the controller debug log. This alert is for informational purposes.

Description A foreign configuration has been cleared.
Cause: The user has attempted to clear a foreign configuration. This alert is for informational purposes.
Description A foreign configuration has been imported.
Cause: The user has attempted to import a foreign configuration. This alert is for informational purposes.
Description The Patrol Read mode has changed.
Cause: The controller has changed the patrol read mode. This alert is for informational purposes.

Description The Patrol Read operation has started.
Cause: The controller has started the Patrol Read operation. This alert is for informational purposes.
Description The Patrol Read operation has stopped.
Cause: The controller has stopped the Patrol Read operation. This alert is for informational purposes.
Clear Alert Number: Alert 2243 is a clear alert for alert 2242.
Description A virtual disk blink has been initiated.
Cause: This alert is for informational purposes.

Description A virtual disk blink has ceased.
Cause: This alert is for informational purposes.
Description Warning / Non-critical
Cause: The temperature of the battery is high. This maybe due to the battery being charged.
Action: As the charge weakens, the charger should automatically recharge the battery. If the battery has reached its recharge limit, replace the battery pack. Monitor the battery to make sure that it recharges successfully.
Description The controller battery is charging.
Cause: This alert is for informational purposes.

Description The controller battery is executing a Learn cycle.
Cause: This alert is for informational purposes.
Description The physical disk Clear operation has started.
Cause: This alert is for informational purposes.
Description Redundant Path is broken.
Cause: The redundant path is broken.
Action: Check the connection to the enclosure, which is degraded.
Severity Warning /Non-critical

Description The physical disk blink has initiated.
Cause: This alert is for informational purposes.
Description The physical disk blink has ceased.
Cause: This alert is for informational purposes.
Description Redundant path restored.
Cause: This alert is for informational purposes.

Description The Clear operation has cancelled.
Cause: This alert is for informational purposes.
Description The physical disk has been started.
Cause: This alert is for informational purposes.
Description Controller preserved cache is discarded.
Cause: The controller cache is discarded by the user. This alert is for informational purposes.
Severity Warning /Non-critical

Description Controller has preserved cache.
Cause: I/O interrupted for a virtual disk which is connected to the controller.
Action: Check for foreign configuration and import if any. Check for cable fault. Recover any virtual disk lost by the controller.
Description An enclosure blink operation has initiated.
Cause: This alert is for informational purposes.
Description An enclosure blink has ceased.
Cause: This alert is for informational purposes.
Severity Warning /Non-critical

Description A global rescan has initiated.
Cause: This alert is for informational purposes.
Description SMART thermal shutdown is enabled.
Cause: This alert is for informational purposes.
Description SMART thermal shutdown is disabled.
Cause: This alert is for informational purposes.

Description A device is missing.
Severity Warning / Non-critical
Cause: The controller cannot communicate with a device. The device may be removed. There may also be a bad or loose cable.
Action: Check if the device is in and not removed. If it is in, check the cables. Also check the connection to the controller battery and the battery health. A battery with a weak or depleted charge may cause this alert.
Description A device is in an unknown state.
Severity Warning / Non-critical
Cause: The controller cannot communicate with a device. The state of the device cannot be determined. There may be a bad or loose cable. The system may also be experiencing problems with the application programming interface (API). There could also be a problem with the driver or firmware.
Action: Check the cables. Check if the controller has a supported version of the driver and firmware. You can download the current version of the driver and firmware from the support site. Rebooting the system may also resolve this problem.
753, 803, 853, 903, 953, 1003, 1053, 1103, 1153, 1203
Cause: The %1 indicates a substitution variable. The text for this substitution variable is generated by the controller and is displayed with the alert in the alert log. This text can vary depending on the situation. This alert is for informational purposes.
753,803,853,903,953,1003,1053,1103,1153,1203

751, 801, 851, 901, 951, 1001, 1051, 1101, 1151, 1201
Description The controller reconstruct rate has changed.
Cause: This alert is for informational purposes.
Description %1, Storage Management has lost communication with the controller. An immediate reboot is strongly recommended to avoid further problems. If the reboot does not restore communication, then contact technical support for more information.
Severity Critical / Failure / Error
Cause: Storage Management has lost communication with a controller. This may occur if the controller driver or firmware is experiencing a problem. The %1 indicates a substitution variable. The text for this substitution variable is displayed with the alert in the alert log and can vary depending on the situation.
Action: Reboot the system. If the problem is not resolved, contact technical support. See your system documentation for information about contacting technical support by using telephone, fax, and Internet services.
Description The physical disk Clear operation has completed.

Cause: This alert is for informational purposes.
Description The physical disk Clear operation failed.
Severity Critical / Failure / Error
Cause: A Clear task was being performed on a physical disk but the task was interrupted and did not complete successfully. The controller may have lost communication with the disk. The disk may have been removed or the cables may be loose or defective.
Action: Verify that the disk is present and not in a Failed state. Make sure the cables are attached securely. See the online help for more information on checking the cables. Restart the Clear task.
Description The Patrol Read encountered a media error.
Cause: The Patrol Read task has encountered an error such as a bad disk block that cannot be remapped. This alert is for informational purposes.

Description Patrol Read found an uncorrectable media error.
Severity Critical / Failure / Error
Cause: The Patrol Read task has encountered an error that cannot be corrected. There may be a bad disk block that cannot be remapped.
Action: Back up your data. If you are able to back up the data successfully, then fully initialize the disk and then restore from back up.
Description A block on the physical disk has been punctured by the controller.
Severity Critical / Failure / Error
Cause: The controller encountered an unrecoverable medium error when attempting to read a block on the physical disk and marked that block as invalid. If the error was encountered on a source physical disk during a rebuild or reconfigure operation, it also punctures the corresponding block on the target physical disk. The invalid block is cleared during a write operation.
Action: Back up your data. If you are able to back up the data successfully, initialize the disk and restore from the back up.
Description The physical disk rebuild has resumed.
Cause: This alert is for informational purposes.

Description The dedicated hot spare is too small.
Severity Warning / Non-critical
Cause: The dedicated hot spare is not large enough to protect all virtual disks that reside on the disk group.
Action: Assign a larger disk as the dedicated hot spare.
Description The global hot spare is too small.
Severity Warning / Non-critical
Cause: The global hot spare is not large enough to protect all virtual disks that reside on the controller.
Action: Assign a larger disk as the global hot spare.
Description The controller battery charge level is below a normal threshold.
Cause: The battery is discharging. A battery discharge is a normal activity during the battery Learn cycle. The battery Learn cycle recharges the battery. You should receive alert 2179 when the recharge occurs.
Action 1: Check if the battery Learn cycle is in progress. The battery also displays the Learn state while the Learn cycle is in progress.
Action 2: If a Learn cycle is not in progress, replace the battery pack.
Severity Warning

Description The controller battery charge level is operating within normal limits.
Cause: This alert indicates that the battery is recharging during the battery Learn cycle. This alert is provided for informational purposes.
Description A disk media error has been corrected.
Cause: A disk media error was detected while the controller was completing a background task. A bad disk block was identified. The disk block has been remapped.
Action: Consider replacing the disk. If you receive this alert frequently, be sure to replace the disk. You should also routinely back up your data.
Description Virtual disk has inconsistent data.
Cause: The virtual disk has inconsistent data. This may be caused when a power loss or system shutdown occurs while data is being written to the virtual disk. This alert is for informational purposes.

Description Hot spare SMART polling failed.
Severity Critical / Failure / Error
Cause: The controller firmware attempted a SMART polling on the hot spare but was unable to complete it. The controller has lost communication with the hot spare.
Action: Check the health of the disk assigned as a hot spare. You may need to replace the disk and reassign the hot spare. Make sure the cables are attached securely. See the Server Administrator Storage Management User’s Guide, for more information on checking the cables.
Description A redundant path is broken.
Severity Warning / Non-critical
Cause: The controller has two connectors that are connected to the same enclosure. The communication path on one connector has lost connection with the enclosure. The communication path on the other connector is reporting this loss.
Action: Make sure the cables are attached securely and both enclosure management modules (EMMs) are healthy. See the Cables Attached Correctly section for more information on checking the cables.

Description A redundant path has been restored.
Cause: This alert is provided for informational purposes.
Clear Alert Number: Alert 2284 is a clear alert for alert 2283.
Description A disk media error was corrected during recovery.
Cause: This alert is for informational purposes.
Description A Learn cycle start is pending while the battery charges.
Cause: This alert is for informational purposes.

Description Protection policy has been changed.
Cause: A new protection policy has been created / existing protection policy has been modified.
Description The patrol read has resumed.
Cause: This alert is for informational purposes.
Description Multi-bit ECC error on controller DIMM.
Severity Critical / Failure / Error
Cause: An error involving multiple bits has been encountered during a read or write operation. The error correction algorithm recalculates parity data during read and write operations. If an error involves only a single bit, it may be possible for the error correction algorithm to correct the error and maintain parity data. An error involving multiple bits, however, usually indicates data loss. In some cases, if the multi-bit error occurs during a read operation, the data on the disk may be OK. If the multi-bit error occurs during a write operation, data loss has occurred.
Action: Replace the dual in-line memory module (DIMM). The DIMM is a part of the controller battery pack. See your hardware documentation for information on replacing the DIMM. You may need to restore data from backup.

Description Single-bit ECC error on controller DIMM.
Severity Warning / Non-critical
Cause: An error involving a single bit has been encountered during a read or write operation. The error correction algorithm has corrected this error.
Description An enclosure management module (EMM) has been discovered.
Cause: This alert is for informational purposes.
Description Communication with the enclosure has been lost.
Severity Critical / Failure / Error
Cause: The controller has lost communication with an EMM. The cables may be loose or defective.
Action: Make sure the cables are attached securely. Reboot the system.

Description The EMM has failed.
Severity Critical / Failure / Error
Cause: The failure may be caused by a loss of power to the EMM. The EMM self test may also have identified a failure. There could also be a firmware problem or a multi-bit error.
Action: Replace the EMM. See the hardware documentation for information on replacing the EMM.
Description A device has been inserted.
Cause: This alert is for informational purposes.
Description A device has been removed.
Severity Critical / Failure / Error
Cause: A device has been removed and the system is no longer functioning in optimal condition.
Action: Replace the device.

Description An EMM has been inserted.
Cause: This alert is for informational purposes.
Description An EMM has been removed.
Severity Critical / Failure / Error
Cause: An EMM has been removed.
Action: Reinsert the EMM. See the hardware documentation for information on replacing the EMM.
Description The enclosure has a bad sensor %1.
Severity Warning / Non-critical
Cause: The enclosure has a bad sensor. The enclosure sensors monitor the fan speeds, temperature probes, and so on. The % indicates a substitution variable. The text for this substitution variable is displayed with the alerts in the alert log and can vary depending on the situation.
Action: See the hardware documentation for more information.
854, 954

Description Bad PHY %1
Severity Critical / Failure / Error
Cause: There is a problem with a physical connection or PHY. The %1 indicates a substitution variable. The text for this substitution variable is displayed with the alert in the alert log and can vary depending on the situation.
Action: Contact your technical support.
Description The enclosure is unstable.
Severity Critical / Failure / Error
Cause: The controller is not receiving a consistent response from the enclosure. There could be a firmware problem or an invalid cabling configuration. If the cables are too long, they degrade the signal.
Action: Power down all enclosures attached to the system and reboot the system. If the problem persists, upgrade the firmware to the latest supported version. You can download the most current version of the driver and firmware from the support site. Make sure the cable configuration is valid. See the hardware documentation for valid cabling configurations.
Description The enclosure has a hardware error.

Severity Critical / Failure / Error
Cause: The enclosure or an enclosure component is in a Failed or Degraded state.
Action: Check the health of the enclosure and its components. Replace any hardware that is in a Failed state. See the hardware documentation for more information.
Description The enclosure is not responding.
Severity Critical / Failure / Error
Cause: The enclosure or an enclosure component is in a Failed or Degraded state.
Action: Check the health of the enclosure and its components. Replace any hardware that is in a Failed state. See the hardware documentation for more information.
Description The enclosure cannot support both SAS and SATA physical disks. Physical disks may be disabled.
Cause: This alert is for informational purposes.

Description An attempt to hot plug an EMM has been detected. This type of hot plug is not supported.
Cause: This alert is for informational purposes.
Description The physical disk is too small to be used for a rebuild.
Severity Warning / Non-critical
Cause: The physical disk is too small to rebuild the data.
Action: Remove the physical disk and insert a new physical disk that is the same size or larger than the disk that is being rebuilt. The new physical disk must also use the same technology (for example, SAS or SATA) as the disk being rebuilt. If the rebuild does not start automatically after you have inserted a suitable physical disk, then run the Rebuild task. See the Server Administrator Storage Management User’s Guide for more information.
Description Bad block table is 80% full.
Severity Warning / Non-critical
Cause: The bad block table is used for remapping bad disk blocks. This table fills, as bad disk blocks are remapped. When the table is full, bad disk blocks can no longer be remapped, and disk errors can no longer be corrected. At this point, data loss can occur. The bad block table is now 80% full.
Action: Back up your data. Replace the disk generating this alert and restore from back up.

Description Bad block table is full. Unable to log block %1.
Severity Critical / Failure / Error
Cause: The bad block table is used for remapping bad disk blocks. This table fills, as bad disk blocks are remapped. When the table is full, bad disk blocks can no longer be remapped and disk errors can no longer be corrected. At this point, data loss can occur. The %1 indicates a substitution variable. The text for this substitution variable is displayed with the alert in the alert log and can vary depending on the situation.
Action: Replace the disk generating this alert. If necessary, restore your data from backup.
Description A physical disk is incompatible.
Severity Warning / Non-critical
Cause: You have attempted to replace a disk with another disk that is using an incompatible technology. For example, you may have replaced one side of a mirror with a SAS disk when the other side of the mirror is using SATA technology.
Action: See the hardware documentation for information on replacing disks.
Description A virtual disk is permanently degraded.

Severity Critical / Failure / Error
Cause: A redundant virtual disk has lost redundancy. This may occur when the virtual disk suffers the failure of multiple physical disks. In this case, both the source physical disk and the target disk with redundant data have failed. A rebuild is not possible because there is no redundancy.
Action: Replace the failed disks and restore from backup.
Description The firmware on the EMMs is not the same version. EMM0 %1 EMM1 %2.
Severity Warning / Non-critical
Cause: The firmware on the EMM modules is not the same version. It is required that both modules have the same version of the firmware. This alert may be caused if you attempt to insert an EMM module that has a different firmware version than an existing module. The %1 and %2 indicate a substitution variable. The text for these substitution variables is displayed with the alert in the alert log and can vary depending on the situation.
Action: Upgrade to the same version of the firmware on both EMM modules.
Description A power supply in the enclosure has an AC failure.
Severity Warning / Non-critical
Cause: The power supply has an AC failure.
Action: Replace the power supply.

Description A power supply in the enclosure has a DC failure.
Severity Warning / Non-critical
Cause: The power supply has a DC failure.
Action: Replace the power supply.
Description The initialization sequence of SAS components failed during system startup. SAS management and monitoring is not possible.
Severity Critical / Failure / Error
Cause: Storage Management is unable to monitor or manage SAS devices.
Action: Reboot the system. If problem persists, make sure you have supported versions of the drivers and firmware. Also, you may need to reinstall Storage Management or Server Administrator because of some missing installation components.
Description Diagnostic message %1
Cause: The %1 indicates a substitution variable. The text for this substitution variable is generated by the utility that ran the diagnostics and is displayed with the alert in the alert log. This text can vary depending on the situation. This alert is for informational purposes.

Description Diagnostic message %1
Severity Critical / Failure / Error
Cause: A diagnostics test failed. The %1 indicates a substitution variable. The text for this substitution variable is generated by the utility that ran the diagnostics and is displayed with the alert in the alert log. This text can vary depending on the situation.
Description Problems with the battery or the battery charger have been detected. The battery health is poor.
Severity Warning / Non-critical
Cause: The battery or the battery charger is not functioning properly.
Action: Replace the battery pack.
Description Single-bit ECC error. The DIMM is degrading.
Severity Warning / Non-critical
Cause: The DIMM is beginning to malfunction.
Action: Replace the DIMM to avoid data loss or data corruption. The DIMM is a part of the controller battery pack. See your hardware documentation for information on replacing the DIMM or contact technical support.

Description Single-bit ECC error. The DIMM is critically degraded.
Severity Critical / Failure / Error
Cause: The DIMM is malfunctioning. Data loss or data corruption may be imminent.
Action: Replace the DIMM immediately to avoid data loss or data corruption. The DIMM is a part of the controller battery pack. See your hardware documentation for information on replacing the DIMM or contact technical support.
Description Single-bit ECC error. The DIMM is critically nonfunctional. There is no further reporting.
Severity Critical / Failure / Error
Cause: The DIMM is malfunctioning. Data loss or data corruption is imminent. No further alerts are generated.
Action: Replace the DIMM immediately. The DIMM is a part of the controller battery pack. See your hardware documentation for information on replacing the DIMM.
Description The DC power supply is switched off.

Cause: The power supply unit is switched off. Either a user switched off the power supply unit or it is defective.
Action: Check if the power switch is turned off. If it is turned off, turn it on. If the problem persists, check if the power cord is attached and functional. If the problem is still not corrected or if the power switch is already turned on, replace the power supply unit.
Description The power supply is switched on.
Cause: This alert is for informational purposes.
Clear Alert Status: Alert 2323 is a clear alert for alerts 2313 and 2322.
Description The AC power supply cable has been removed.
Severity Critical / Failure / Error
Cause: The power cable may be pulled out or removed. The power cable may also have overheated and become warped and nonfunctional.
Action: Replace the power cable.
Severity Informational

Description The power supply cable has been inserted.
Cause: This alert is for informational purposes.
Clear Alert Status: Alert 2325 is a clear alert for alerts 2324 and 2312.
Description A foreign configuration has been detected.
Cause: This alert is for informational purposes. The controller has physical disks that were moved from another controller. These physical disks contain virtual disks that were created on the other controller. See the Import Foreign Configuration and Clear Foreign Configuration section in the Server Administrator Storage Management User’s Guide for more information.
Description The NVRAM has corrupted data. The controller is reinitializing the NVRAM.
Severity Warning / Non-critical
Cause: The nonvolatile random access memory (NVRAM) is corrupt. This may occur after a power surge, a battery failure, or for other reasons. The controller is reinitializing the NVRAM. The controller properties reset to the default settings after the reinitialization is complete.

Description The NVRAM has corrupt data.
Severity Warning / Non-critical
Cause: The NVRAM has corrupt data. The controller is unable to correct the situation.
Action: Replace the controller.
Severity Warning / Non-critical
Cause: The text for this alert is generated by the controller and can vary depending on the situation. The %1 indicates a substitution variable. The text for this substitution variable is generated by the controller and is displayed with the alert in the alert log. This text can vary depending on the situation.
Action: Run the PHY integrity test diagnostic. Make sure the cables are attached securely. If the problem persists, replace the cable with a valid cable according to SAS specifications. If the problem still persists, you may need to replace some devices such as the controller or EMM. See the hardware documentation for more information.

Cause: The %1 indicates a substitution variable. The text for this substitution variable is generated by the controller and is displayed with the alert in the alert log. This text can vary depending on the situation. This alert is for informational purposes.
Description A bad disk block has been reassigned.
Cause: The disk has a bad block. Data has been readdressed to another disk block and no data loss has occurred.
Action: Monitor the disk for other alerts or indications of poor health. For example, you may receive alert 2306. Replace the disk if you suspect there is a problem.
Description A controller hot plug has been detected.
Cause: This alert is for informational purposes.

Cause: The %1 indicates a substitution variable. The text for this substitution variable is generated by the controller and is displayed with the alert in the alert log. This text is from events in the controller event log that were generated while Storage Management was not running. This text can vary depending on the situation. This alert is for informational purposes.
Description Controller event log: %1.
Severity Warning / Non-critical
Cause: The %1 indicates a substitution variable. The text for this substitution variable is generated by the controller and is displayed with the alert in the alert log. This text is from events in the controller event log that were generated while Storage Management was not running. This text can vary depending on the situation.
Action: If there is a problem, review the controller event log and the Server Administrator alert log for significant events or alerts that may assist in diagnosing the problem. Check the health of the storage components. See the hardware documentation for more information.
Description Controller event log: %1.
Severity Critical / Failure / Error
Cause: The %1 indicates a substitution variable. The text for this substitution variable is generated by the controller and is displayed with the alert in the alert log. This text is from events in the controller event log that were generated while

Storage Management was not running. This text can vary depending on the situation.
Action: See the hardware documentation for more information.
Description The controller is unable to recover cached data from the battery backup unit (BBU).
Severity Critical / Failure / Error
Cause: The controller was unable to recover data from the cache. This may occur when the system is without power for an extended period when the battery is discharged.
Action: Check if the battery is charged and in good health. When the battery charge is unacceptably low, it cannot maintain cached data. Check if the battery has reached its recharge limit. The battery may need to be recharged or replaced.
Description The controller has recovered cached data from the BBU.
Cause: This alert is for informational purposes.
Description The factory default settings have been restored.

Cause: This alert is for informational purposes.
Description The BGI completed with uncorrectable errors.
Severity Critical / Failure / Error
Cause: The BGI task encountered errors that cannot be corrected. The virtual disk contains physical disks that have unusable disk space or disk errors that cannot be corrected.
Action: Replace the physical disk that contains the disk errors. Review other alert messages to identify the physical disk that has errors. If the virtual disk is redundant, you can replace the physical disk and continue using the virtual disk. If the virtual disk is non-redundant, you may need to recreate the virtual disk after replacing the physical disk. After replacing the physical disk, run Check Consistency to check the data.
Description The Check Consistency made corrections and completed.
Cause: This alert is for informational purposes.

Description The Check Consistency found inconsistent parity data. Data redundancy may be lost.
Severity Warning / Non-critical
Cause: The data on a source disk and the redundant data on a target disk is inconsistent.
Action: Restart the Check Consistency task. If you receive this alert again, check the health of the physical disks included in the virtual disk. Review the alert messages for significant alerts related to the physical disks. If you suspect that a physical disk has a problem, replace it and restore from backup.
Description The Check Consistency logging of inconsistent parity data is disabled.
Severity Warning / Non-critical
Cause: The Check Consistency can no longer report errors in the parity data.
Action: See the hardware documentation for more information.
Description The virtual disk initialization terminated.
Severity Warning / Non-critical
Cause: A user has cancelled the virtual disk initialization.
Action: Restart the initialization.

Description The virtual disk initialization failed.
Severity Critical / Failure / Error
Cause: The controller cannot communicate with attached devices. A disk may be removed or contain errors. Cables may also be loose or defective.
Action: Verify the health of attached devices. Review the Alert Log for significant events. Make sure the cables are attached securely. See the Cables Attached Correctly section for more information on checking the cables.
Description Error occurred: %1.
Severity Warning / Non-critical
Cause: A physical device may have an error. The %1 indicates a substitution variable. The text for this substitution variable is generated by the firmware and is displayed with the alert in the alert log. This text can vary depending on the situation.
Action: Verify the health of attached devices. Review the alert log for significant events. Run the PHY integrity diagnostic tests. You may need to replace faulty hardware. Make sure that the cables are attached securely. See the hardware documentation for more information.
Related Alert Number: 2048, 2050, 2056, 2057, 2076, 2079, 2081, 2083, 2095, 2129, 2201, 2203, 2270, 2282, 2369
Description The rebuild failed due to errors on the source physical disk.
Severity Critical / Failure / Error

Cause: You are attempting to rebuild data that resides on a defective disk.
Action: Replace the source disk and restore from backup.
Software RAID:
Description The rebuild failed due to errors on the target physical disk.
Severity Critical / Failure / Error
Cause:You are attempting to rebuild data on a disk that is defective.
Action: Replace the target disk. If a rebuild does not automatically start after replacing the disk, initiate the Rebuild task. You may need to assign the new disk as a hot spare to initiate the rebuild.
Description A bad disk block could not be reassigned during a write operation.
Severity Critical / Failure / Error
Cause: A write operation could not complete because the disk contains bad disk blocks that could not be reassigned. Data loss may have occurred and data redundancy may also be lost.
Action: Replace the disk.

Description There was an unrecoverable disk media error during the rebuild or recovery operation.
Severity Critical / Failure / Error
Cause: The rebuild or recovery operation encountered an unrecoverable disk media error.
Action: Replace the disk.
Description A physical disk is marked as missing.
Cause: This alert is for informational purposes.
Description A physical disk that was marked as missing has been replaced.
Cause: This alert is for informational purposes.
Clear Alert Status: Alert 2352 is a clear alert for alert 2351.

Description The enclosure temperature has returned to normal.
Cause: This alert is for informational purposes.
Clear Alert Status: Alert 2353 is a clear alert for alerts 2100 and 2101.
Description Enclosure firmware download in progress.
Cause: This alert is provided for informational purposes.
Description Enclosure firmware download failed.
Severity Warning / Non-critical
Cause: The system was unable to download firmware to the enclosure. The controller may have lost communication with the enclosure. There may have been problems with the data transfer or the download media may be corrupt.
Action: Attempt to download the enclosure firmware again. If problems continue, verify that the controller can communicate with the enclosure. Make sure that the enclosure is powered on. Check the cables. See the Cables Attached Correctly section for more information on checking the cables. Verify the health of the enclosure and its components. To verify the health of the enclosure, select the enclosure object in the tree view. The Health subtab displays a red X or yellow exclamation point for enclosure components that are failed or degraded.

Description SAS SMP Communications error %1.
Severity Critical / Failure / Error
Cause: The text for this alert is generated by the firmware and can vary depending on the situation. The reference to SMP in this text refers to SAS Management Protocol.
Action: There may be a SAS topology error. See the hardware documentation for information on correct SAS topology configurations. There may be problems with the cables such as a loose connection or an invalid cabling configuration. See the Cables Attached Correctly section for more information on checking the cables. See the hardware documentation for information on correct cabling configurations. Verify that the firmware is a supported version.
Description SAS expander error: %1.
Severity Critical / Failure / Error
Cause: The %1 indicates a substitution variable. The text for this substitution variable is generated by the firmware and is displayed with the alert in the alert log. This text can vary depending on the situation.
Action: There may be a problem with the enclosure. Check the health of the enclosure and its components by selecting the enclosure object in the tree view. The Health subtab displays a red X or yellow exclamation point for enclosure components that are Failed or Degraded. See the enclosure documentation for more information.

Description The battery charge cycle is complete.
Cause: This alert is for informational purposes.
Description Disk found is not supplied by an authorized hardware provider.
Severity Warning / Non-critical
Cause: The physical disk does not comply with the standards set and is not supported.
Action: Replace the physical disk with a physical disk that is supported.
Description A user has discarded data from the controller cache.
Cause: This alert is for informational purposes.

Description Physical disk(s) that are part of a virtual disk have been removed while the system was shut down. This removal was discovered during system start-up.
Cause: This alert is for informational purposes.
Description Physical disk(s) have been removed from a virtual disk. The virtual disk is in Failed state during the next system reboot.
Cause: This alert is for informational purposes.
Description All virtual disks are missing from the controller. This situation was discovered during system start-up.
Cause: This alert is for informational purposes.
Severity Warning · Severity Warning

Description Dedicated spare imported as global due to missing arrays.
Cause: This alert is for informational purposes.
Description Rebuild is not possible because mixing of different media type (SSD/HDD) and bus protocols (SATA/SAS) is not supported on the same virtual disk.
Severity Warning / Non-critical
Cause: The physical disk is using an incompatible technology.
Action: All physical disks in the virtual disk must use the same technology. You cannot use both SAS and SATA physical disks in the same virtual disk. Remove the physical disk and insert a new physical disk that uses the correct technology. If the rebuild does not start automatically after you have inserted a suitable physical disk, then run the Rebuild task.
Description The SCSI Enclosure Processor (SEP) has been rebooted as part of the firmware download operation and is unavailable until the operation completes.
Cause: This alert is for informational purposes.

Description Virtual Disk Redundancy has been degraded.
Cause: A physical disk in a RAID 6 virtual disk has either failed or been removed.
Action: Replace the missing or failed physical disk.
Description Redundant Path View cleared.
Cause: This alert is for informational purposes.
Description Attempted import of Unsupported Virtual Disk type RAID%1.
Cause: This alert is for informational purposes.

Description Attempted import of Virtual Disk exceeding the limit supported on the controller.
Cause: This alert is provided for informational purposes.
Description Attempted import of unsupported Virtual Disk type RAID %1.
Cause: This alert is provided for informational purposes. User is attempting to import a foreign virtual disk with unsupported RAID level on the controller.
Description Attempted import of Virtual Disk with missing span.
Cause: This alert is provided for informational purposes and is displayed when you attempt to import a foreign virtual disk with a missing span.

Description Attempted import of Virtual Disk with missing physical disk.
Cause: User is attempting to import a foreign virtual disk with a missing physical disk. This alert is provided for informational purposes.
Description Attempted import of Virtual Disk with stale physical disk.
Cause: User is attempting to import a foreign virtual disk with a stale physical disk. This alert is provided for informational purposes.
Description Attempted import of an orphan drive.
Cause: User is attempting to import an orphan drive. This alert is provided for informational purposes.

Description Attempted import of an incompatible physical drive.
Cause: User is attempting to import an incompatible physical drive. This alert is provided for informational purposes.
Description An overflow of the foreign configuration has occurred. You can import the foreign configuration in multiple attempts.
Cause: This alert is provided for informational purposes.
Description Foreign configuration has been partially imported. Some configuration failed to import.
Cause: This alert is provided for informational purposes.
Severity Warning

Description Controller preserved cache is recovered.
Cause: This alert is provided for informational purposes.
Description An unsupported configuration was detected. The controller does not support physical disks of type SSD: , ,
Severity Warning / Non-critical
Cause: A physical disk of media type SSD is attached to a controller that does not support SSD disks.
Action: Replace the unsupported physical disk with a physical disk of media type HDD.
Description The Information level set for the hot spare protection policy is violated for the Virtual Disk.
Cause: The number of physical disks you specified for the hot spare protection policy is violated.
Action: Reassign the number of hot spares as specified in the protection policy for that RAID level.

Description The Warning level set for the hot spare protection policy is violated for the Virtual Disk.
Severity Warning / Non-critical
Cause: The number of physical disks you specified for the hot spare protection policy is violated.
Action: Reassign the number of hot spares as specified in the protection policy for that RAID level.
Description The Critical level set for the hot spare protection policy is violated for the Virtual Disk.
Severity Critical / Failure / Error
Cause: The number of physical disks you specified for the hot spare protection policy is violated.
Action: Reassign the number of hot spares as specified in the protection policy for that RAID level.
Description Drive could not be assigned as Dedicated Hot Spare.
Cause: The assignment of a Dedicated Hot Spare fails as the disk is invalid.
Severity Informational

Description A virtual disk bad block medium error is detected.
Severity Critical / Failure / Error
Cause: Virtual disk bad blocks are due to presence of unrecoverable bad blocks on one or more member physical disks.
Action:
– Backup operation fails. In this case, restore the file from a previous backup. After restoring the file, run Patrol Read and check for bad blocks. If more bad blocks exist, proceed to step 2.
– Backup operation completes without error. This indicates that there are no bad blocks on your virtual disk.
– Backup operation displays bad blocks. This indicates that the bad blocks are located in a nondata area. Proceed to step 2.
Description The Controller Encryption Key is destroyed.
Cause: The Controller Encryption Key is destroyed.

Description The virtual disk bad block medium error is cleared.
Cause: Virtual disk bad blocks are cleared.
Description The Instant Encrypt Erase operation is performed on the physical disk.
Description The drive Encryption Key is invalid.
Severity Warning / Non-critical
Cause: The controller failed to verify the specified Passphrase.
Action: Enter a correct Passphrase.

Description The virtual disk is encrypted.
Cause: The Encrypted virtual disk operation on normal virtual disk (created using Self encrypting disks only) is successful.
Description Persistent Hot Spare is enabled.
Cause: The Persistent Hot Spare option is enabled.
Description Persistent Hot Spare is disabled.
Cause: The Persistent Hot Spare option is disabled.

Description The Check Consistency detected uncorrectable multiple medium errors.
Severity Critical / Failure / Error
Cause: The Check Consistency task detects uncorrectable multiple errors.
Action: Replace the failed physical disk. You can identify the failed disk by locating the disk that has a red “X” for its status. Rebuild the physical disk. When finished, restart the check consistency operation.
Description The Check Consistency completed with uncorrectable errors.
Severity Critical / Failure / Error
Cause: The Check Consistency task detected uncorrectable multiple errors.
Action: Replace the failed physical disk. You can identify the failed disk by locating the disk that has a red “X” for its status. Rebuild the physical disk. When finished, restart the check consistency operation.
Description The Manage Physical Disk Power property(s) changed.
Cause: The Manage Physical Disk Power properties are changed.

Description The Physical Disk Power status changed from 1% to 2%.
Cause: The physical disk power status is changed from one state to another. A physical disk can have the following power statuses: spun down, transition, and spun up.
Description Physical disk configuration data updated as it was stale.
Cause: The physical disk configuration data is updated because it was outdated.
Description Configuration command could not be committed to disk. Configuration has to be re applied.
Severity Failure / Error
Cause: The virtual disk configuration command did not succeed.
Action: Check for the recent configuration that has not taken effect. Re-apply the configuration.
Severity Informational

Description Changing the Physical Disk Power status from 1% to 2% failed.
Severity Failure / Error
Cause: When changing the Physical Disk Power status fails.
Action: Replace the physical disk.
Description Virtual Disk is available.
Cause: The operating system detects the newly created virtual disk.
Description Virtual Disk is not available.
Cause: The operating system does not detect the newly created virtual disk.
Action: Wait for some time.

Description Command timeout on physical disk.
Cause: The spundown physical disks take more time than the timeout period and the configuration commands are timed out.
Description Controller Encryption mode is enabled in LKM.
Cause: The Local Key Management (LKM) encryption mode is enabled.
Description Controller LKM Encryption key is changed.
Cause: Using Manage Encryption Key operations, encryption key is changed.
Severity Warning · Severity Informational · Severity Informational

Description Controller CacheCade is resized.
Cause: This alert is provided for informational purposes.
Description Controller CacheCade is created.
Cause: This alert is provided for informational purposes.
Description Controller CacheCade is deleted.
Cause: This alert is provided for informational purposes.
Severity Informational · Severity Informational · Severity Informational

Description Controller battery is discharging.
Cause: The battery learn cycle has started.
Description Disk medium error detected.
Severity Warning / Non-critical
Cause: A part of the physical disk is damaged.
Description There is an unrecoverable medium error detected on virtual disk.
Severity Critical / Failure / Error
Cause: Unrecoverable medium error found on one or more member physical disks of a virtual disk.
Action: Perform a backup of the virtual disk with the Verify option selected. If the Backup operation is successful, it indicates that the un-recoverable medium did not affect user data.
If the Backup operation fails, restore the file from a previous backup. After restoring the file, run check consistency operation:
Severity Informational

Description Disk medium error on virtual disk has been corrected
Cause: This alert is for informational purposes.
Description State change on Physical disk from READY to Non-RAID.
Cause: User triggered action.
Action: Configure the drive to be non-raid using CLI/GUI.
Severity Informational · Severity Informational

Description State change on Physical disk from Non- RAID to READY.
Cause: User triggered action.
Action: Configure the drive to be ready using CLI/GUI.
Description Drive Prepared for Removal.
Cause: User triggered action.
Description Physical Device Log Exported.
Cause: User triggered action.
Action: Execute export log for physical device.
Severity Informational · Severity Informational · Severity Warning

Description Physical Device Full Initialization completed.
Cause: User triggered task.
Description The PCIeSSD device was found to be in security locked state. Full initialization has to be done on the security locked drive to recover the drive in usable state.
Cause: Last full initialization was stopped for some reason and hence the device is in security locked state.
Action: Run full initialization to recover the device.
Description Physical Device is at %1% of warranted device wear-out limit.
Cause: User triggered task.
Severity Informational · Severity Warning · Severity Informational

Description Physical Device has reached or exceeded its warranted device wear-out limit.
Cause: User triggered task.
Description Physical Device is approaching read-only mode.
Cause: User triggered task.
Description Physical Device is in read-only mode.
Cause: User triggered task.
Severity Warning · Severity Informational · Severity Critical

Description The physical device blink has initiated.
Cause: User triggered task.
Description The physical device blink has ceased.
Cause: User triggered task.
Description The physical device volatile memory backup device failed.
Severity Informational · Severity Informational · Severity Error

Description The PCIe solid state device identified in the message has turned off because the critical temperature threshold of the device was exceeded.
Action: Contact your service provider.
Description The reliability of the PCIe solid state device identified in the message degraded. Data loss is possible.
Action: Back up the data on the device, and contact your service provider for further instructions.
Description The volatile memory backup device on the PCIe solid state device identified in the message is no longer functional. Data loss is possible.
Action: Back up the data on the device, and contact your service provider for further instructions.
Severity Error · Severity Error · Severity Error

Description The Patrol Read operation was manually stopped before completion.
Action: If desired, restart the Patrol Read operation at a later time.
Description Cryptographic Erase operation is successfully completed on the physical disk drive identified in the message.
Action: No response action is required.
No action required.
Severity Informational · Severity Informational · Severity Error

Description The following journal mirror is available. %1
No action required.
Description The following journal mirror is being replaced.(wwn ) %1 : FluidCache.
No action required.
Description The following journal mirror has failed. (wwn) %1 : FluidCache.
No action required.
Severity Information · Severity Information · Severity Warning

Description There are not enough journal mirrors available to operate. : FluidCache.
To resolve the issue, you must ensure that there are at least two journal mirrors that are accessible. You must activate either one or more failed cache devices or use the fldc_restore utility to rebuild the node.
Description The cluster ID in the journal does not match the cluster ID in the configuration file. : FluidCache.
Service is required. Contact Dell Technical Support.
Description The journal could not be read/written. : FluidCache.
Service is required. Contact Dell Technical Support.
Severity Error · Severity Error · Severity Error

Description The following Cache Device has no associated server in the configuration: %1 : FluidCache.
There is a cache device specified in the configuration with no associated cache server configured.
Description The following Disk is beginning flushing.(wwn) %1 (path) %2 : FluidCache.
No action required.
Description The following Disk has finished flushing. (wwn) %1 (path) %2 : FluidCache.
No action required.
Severity Warning · Severity Information · Severity Information

Description The following cache device has failed. (wwn) %1 (path) %2 : FluidCache.
Replace the failed device.
Description The following storage device is either inaccessible or failed. (wwn) %1 (path) %2 : FluidCache.
If the device is inaccessible, restore connectivity. If the device has failed, replace it.
Description The following storage device has had transient failures. (wwn) %1 (path) %2 : FluidCache.
No action required.

Description The following cache device has been registered. (ww n) %1 (path) %2 : FluidCache.
No action required.
Description The following cache device has been removed. (wwn ) %1 (path) %2 : FluidCache.
No action required.
Description The following cache device is being removed. (wwn ) %1 (path) %2 : FluidCache.
No action required.
Description Caching is being removed for the following storage device. (wwn) %1 (path) %2 : FluidCache.
Severity Information · Severity Information · Severity Information

No action required.
Description Caching has been enabled on the following storage device. (wwn) %1 (path) %2 : FluidCache.
No action required.
Description The following cache device has been disconnected. (wwn) %1 (path) %2 : FluidCache.
No action required.
Description The following journal mirror is available. %1The following storage device is in an unknown state.(wwn) %1 (path) %2 : FluidCache.

Service is required. Contact Dell Technical Support.
Description Caching has been disabled for the following storage device. (wwn) %1 (path) %2 : FluidCache.
No action required.
Description The following cached LUN has had a failure. (wwn) %1 (path) %2 : FluidCache.
Service is required. Contact Dell Technical Support.
Description Resilvering for the following cache device is complete .(wwn) %1 (path) %2 : FluidCache.
No action required.

Description The following failed cache device has completed recovery. (wwn) %1 (path) %2 : FluidCache.
No action required.
Description A valid permanent license is installed.: FluidCache.
No action required.
Description No valid license is installed.: FluidCache.
A valid license must be installed.
Severity Information · Severity Information · Severity Error

Description Running on an evaluation license. Days remaining %1 (days): FluidCache.
A permanent license should be purchased.
Description Running on an expired evaluation license. No configuration changes will be allowed. Expired days: % 1: FluidCache.
A permanent license must be installed.
Description Running on an expired evaluation license. Caching functionality is disabled. Expired days: % 1: FluidCache
A permanent license must be installed.
Severity Information · Severity Error · Severity Error

Description Running on an expired/invalid license. Configuration changes are disabled.: FluidCache.
A valid permanent license must be installed.
Description A license has been installed.: FluidCache.
No action required.
Description A license has been removed.: FluidCache.
A license should be installed.
Severity Error · Severity Information · Severity Information

Description Not enough memory to run necessary services.: FluidCache.
You must run on a system with adequate memory.
Description One or more cache devices are missing. Cache is hung.: FluidCache.
To resolve the issue, insert the missing cache device. If the cache device was unplugged, reactivate it.
Description All cache devices have been found and registered.: FluidCache.
No action required.
Severity Error · Severity Error · Severity Information

Description Even though caching was enabled in write-back mode, it is currently operating in write-through mode.: FluidCache.
To resolve the issue, add a PCIe SSD to the cache pool.
Description Even though caching was enabled in write-back or write-through mode, it is currently operating in pass-through mode.: FluidCache.
To resolve the issue, add one or more PCIe SSDs to the cache pool.
Description Caching is no longer degraded to write-through mode and is now operating in write-back mode.: FluidCache.
No action required.

Description Caching is no longer degraded to pass-through mode and is now operating in its configured mode.: FluidCache.
No action required.
Severity Warning · 1203, 1503



The tables in this chapter list the system event log (SEL) messages, their severity, and cause.
The temperature sensor event messages help protect critical components by alerting the systems management console when the temperature rises inside the chassis. These event messages use additional variables, such as sensor location, chassis location, previous state, and temperature sensor value or state.
Table 5. Temperature Sensor Events
Event Message Severity Cause
temperature sensor detected a failure where is the entity that this sensor is monitoring. For example, "PROC Temp" or "Planar Temp." Reading is specified in degree Celsius. For example 100 C.
Critical Temperature of the backplane board, system board, or the carrier in the specified system exceeded the critical threshold.
temperature sensor detected a warning .
temperature sensor returned to warning state .
temperature sensor returned to normal state .
Information Temperature of the backplane board, system board, or the carrier in the specified system returned to normal operating range.
The temperature is less than the lower warning threshold.

Event Message Severity Cause
The temperature is less than the lower critical threshold.
Critical Temperature of the backplane, system board, system inlet, or the carrier in the specified system entered into critical state.
The temperature is greater than the upper warning threshold.
The temperature is greater than the upper critical threshold.
Critical Temperature of the backplane, system board, system inlet, or the carrier in the specified system entered into critical state.
The temperature is outside of range.
Critical Temperature of the backplane, system board, system inlet, or the carrier in the specified system is outside of normal operating range.
The temperature is within range.
Information Temperature of the backplane, system board, system inlet, or the carrier in the specified system returned to a normal operating range.
The voltage sensor event messages monitor the number of volts across critical components. These messages provide status and warning information for voltage sensors for a particular chassis.
Table 6. Voltage Sensor Events
Event Message Severity Cause
voltage sensor detected a failure where is the entity that this sensor is monitoring. Reading is specified in volts. For example, 3.860 V.
Critical The voltage of the monitored device has exceeded the critical threshold.
voltage sensor state asserted.
Critical The voltage specified by is in critical state.
voltage sensor state de- asserted.
Information The voltage of a previously reported is returned to normal state.

Event Message Severity Cause
voltage sensor detected a warning .
voltage sensor returned to normal .
Information The voltage of a previously reported is returned to normal state.
The voltage is less than the lower warning threshold.
The voltage is less than the lower critical threshold.
Critical Voltage of the monitored Entity exceeded the critical threshold.
The voltage is greater than the upper warning threshold.
The voltage is greater than the upper critical threshold.
Critical Voltage of the monitored Entity exceeded the critical threshold.
The voltage is outside of range.
Critical Voltage of the monitored Entity is outside of normal operating range.
The voltage is within range.
Information Voltage of the monitored Entity returned to a normal operating range.
The cooling device sensors monitor how well a fan is functioning. These messages provide status warning and failure messages for fans for a particular chassis.
Table 7. Fan Sensor Events
Event Message Severity Cause
Fan sensor detected a failure where
Critical The speed of the specified fan is not sufficient to provide enough cooling to the system.

Event Message Severity Cause
is the entity that this sensor is monitoring. For example "BMC Back Fan" or "BMC Front Fan." Reading is specified in RPM. For example, 100 RPM.
Fan sensor returned to normal state .
Information The fan specified by has returned to its normal operating speed.
Fan sensor detected a warning .
Fan Redundancy sensor redundancy degraded.
Information The fan specified by may have failed and hence, the redundancy has been degraded.
Fan Redundancy sensor redundancy lost.
Critical The fan specified by may have failed and hence, the redundancy that was degraded previously has been lost.
Fan Redundancy sensor redundancy regained
Information The fan specified by may have started functioning again and hence, the redundancy has been regained.
Fan RPM is less than the lower warning threshold.
Fan RPM is less than the lower critical threshold.
Critical The speed of the specified fan is not sufficient to provide enough cooling to the system.
Fan RPM is greater than the upper warning threshold.
Fan RPM is greater than the upper critical threshold.
Critical The speed of the specified fan exceeded the critical threshold.
Fan RPM is outside of range.
Critical The speed of the specified fan might not provide enough cooling to the system.

Event Message Severity Cause
Fan RPM is within range.
Information The speed of the specified fan is operating in a normal range.
Fan is removed. Critical A required fan was removed.
Fan was inserted.
Information A fan was added.
Fan is present. Information The total number of fans present.
Fan is absent. Critical A required fan is missing.
The fans are redundant. Information One or more fans may have started functioning or installed and the redundancy has been regained.
Fan redundancy is lost. Critical One or more required fans may have failed or removed and hence, the redundancy was lost.
Fan redundancy is degraded.
The processor status messages monitor the functionality of the processors in a system. These messages provide processor health and warning information of a system.
Table 8. Processor Status Events
Event Message Severity Cause
status processor sensor IERR, where is the processor that generated the event. For example, PROC for a single processor system and PROC # for multiprocessor system.
Critical IERR internal error generated by the . This event is generated due to processor internal error.
status processor sensor Thermal Trip.
Critical The processor generates this event before it shuts down because of excessive heat caused by lack of cooling or heat synchronization.
status processor sensor recovered from IERR.
Information This event is generated when a processor recovers from the internal error.

Event Message Severity Cause
status processor sensor disabled.
status processor sensor terminator not present.
Information This event is generated if the terminator is missing on an empty processor slot.
presence was deasserted.
Critical This event is generated when the system could not detect the processor.
presence was asserted.
Information This event is generated when the earlier processor detection error was corrected.
thermal tripped was deasserted.
Information This event is generated when the processor has recovered from an earlier thermal condition.
configuration error was asserted.
Critical This event is generated when the processor configuration is incorrect.
configuration error was deasserted.
Information This event is generated when the earlier processor configuration error was corrected.
throttled was asserted.
throttled was deasserted.
Information This event is generated when the earlier processor throttled event was corrected.
CPU has an internal error (IERR).
Critical The specified CPU generated an internal error.
CPU has a thermal trip (over- temperature) event.
Critical The CPU generates this event before it shuts down because of excessive heat caused by lack of cooling or heat synchronization.
CPU configuration is unsupported.
CPU is present. Information The specified CPU is present.
CPU terminator is present.
Information This event is generated if the terminator is present on a processor slot.

Event Message Severity Cause
CPU terminator is absent.
CPU is throttled.
CPU is absent. Critical This event is generated when the system could not detect the processor.
CPU is operating correctly.
Information This event is generated when the processor recovered from an error.
CPU is configured correctly.
Information The specified CPU is configured correctly.
The power supply sensors monitor the functionality of the power supplies. These messages provide status and warning information for power supplies for a particular system.
Table 9. Power Supply Events
Event Message Severity Cause
power supply sensor removed.
Critical This event is generated when the power supply sensor is removed.
power supply sensor AC recovered.
Information This event is generated when the power supply has been replaced.
power supply sensor returned to normal state.
Information This event is generated when the power supply that failed or removed was replaced and the state has returned to normal.
PS Redundancy sensor redundancy degraded.
Information Power supply redundancy is degraded if one of the power supply sources is removed or failed.
PS Redundancy sensor redundancy lost.
Critical Power supply redundancy is lost if only one power supply is functional.
PS Redundancy sensor redundancy regained.
Information This event is generated if the power supply has been reconnected or replaced.

Event Message Severity Cause
predictive failure was asserted.
Critical This event is generated when the power supply is about to fail.
input lost was asserted.
Critical This event is generated when the power supply is unplugged.
predictive failure was deasserted.
Information This event is generated when the power supply has recovered from an earlier predictive failure event.
input lost was deasserted.
Information This event is generated when the power supply is plugged in.
PS 1 Status: Power supply sensor for PS 1, presence was asserted.
Information This event is generated when the power supply is plugged in.
PS 1 Status: Power supply sensor for PS 1, presence was deasserted.
Critical This event is generated when the power supply is removed.
PS 1 Status: Power supply sensor for PS 1, failure was asserted.
Critical This event is generated when the power supply has failed.
PS 1 Status: Power supply sensor for PS 1, failure was deasserted.
Information This event is generated when the power supply has recovered from an earlier failure event.
PS 1 Status: Power supply sensor for PS 1, predictive failure was asserted.
PS 1 Status: Power supply sensor for PS 1, predictive failure was deasserted.
Information This event is generated when the power supply has recovered from an earlier predictive failure event.
PS 1 Status: Power supply sensor for PS 1, input lost was asserted.
Critical This event is generated when AC power is removed from the power supply.
PS 1 Status: Power supply sensor for PS 1, input lost was deasserted.
Information This event is generated when the power supply is plugged in.

Event Message Severity Cause
PS 1 Status: Power supply sensor for PS 1, configuration error was asserted.
PS 1 Status: Power supply sensor for PS 1, configuration error was deasserted.
Information This event is generated when the power supply has recovered from an earlier invalid configuration.
Power supply is present.
Information This event is generated when the power supply is plugged in.
Power supply is absent.
Critical This event is generated when the power supply is removed.
Power supply failed.
Critical This event is generated when the power supply has failed.
A predictive failure detected on power supply .
The power input for power supply is lost.
Critical This event is generated when input power is removed from the power supply.
The input power for power supply has been restored.
Information This event is generated if the power supply has been reconnected or replaced.
Power supply is incorrectly configured.
Critical/Warning This event is generated when an invalid power supply configuration is detected.
Power supply is correctly configured.
Information This event is generated when the power supply has recovered from an earlier invalid configuration.
Power supply is operating normally.
Information This event is generated when the power supply has recovered from an earlier failure event.
Cannot communicate with power supply .
Critical The power supply may operate, however power supply monitoring is degraded.
The temperature for power supply is in a warning range.

Event Message Severity Cause
The temperature for power supply is outside of range.
Critical Temperature of specified power supply entered into critical state.
An under voltage fault detected on power supply .
Critical The specified power supply detected inefficient voltage.
An over voltage fault detected on power supply .
Critical The specified power supply detected an over voltage condition.
An over current fault detected on power supply .
Crotoca; The specified power supply detected an over current condition.
Fan failure detected on power supply .
Critical The specified power supply fan has failed.
Communication has been restored to power supply .
Information This event is generated when the power supply has recovered from an earlier communication problem.
A power supply wattage mismatch is detected; power supply is rated for watts.
Critical This event is generated when there is more than one power supplies in the system and the power supply wattage do not match.
Power supply wattage mismatch corrected.
Information This event is generated when the power supply has recovered from an earlier power supply wattage mismatch.
Power supply redundancy is lost.
Critical Power supply redundancy is lost if only one power supply is functional.
Power supply redundancy is degraded.
The power supplies are redundant.
Information This event is generated if the power supply has been reconnected or replaced.

The memory ECC event messages monitor the memory modules in a system. These messages monitor the ECC memory correction rate and the type of memory events that occurred.
Table 10. Memory ECC Events
Event Message Severity Cause
ECC error correction detected on Bank # DIMM [A/B].
Information This event is generated when there is a memory error correction on a particular Dual Inline Memory Module (DIMM).
ECC uncorrectable error detected on Bank # [DIMM].
Critical This event is generated when the chipset is unable to correct the memory errors. Usually, a bank number is provided and DIMM may or may not be identifiable, depending on the error.
Correctable memory error logging disabled.
Critical This event is generated when the chipset in the ECC error correction rate exceeds a predefined limit.
Persistent correctable memory errors detected on a memory device at location(s) .
Multi-bit memory errors detected on a memory device at location(s) .
Critical This event is generated when the chipset is unable to correct the memory errors. Usually, more than on DIMM is listed because a single DIMM may or may not be identifiable, depending on the error.
Correctable memory error logging disabled for a memory device at location .
Critical This event is generated when the chipset in the ECC error correction rate exceeds a predefined limit.

Enter a short description for your reference topic. This should be one or two sentences that describes the topic content.
Table 11. BMC Watchdog Events
Event Message Severity Cause
BMC OS Watchdog timer expired.
Information This event is generated when the BMC watchdog timer expires and no action is set.
BMC OS Watchdog performed system reboot.
Critical This event is generated when the BMC watchdog detects that the system has crashed (timer expired because no response was received from Host) and the action is set to reboot.
BMC OS Watchdog performed system power off.
Critical This event is generated when the BMC watchdog detects that the system has crashed (timer expired because no response was received from Host) and the action is set to power off.
BMC OS Watchdog performed system power cycle.
Critical This event is generated when the BMC watchdog detects that the system has crashed (timer expired because no response was received from Host) and the action is set to power cycle.
The OS watchdog timer reset the system.
Critical This event is generated when the BMC watchdog detects that the system has crashed (timer expired because no response was received from Host) and the action is set to reboot.
The OS watchdog timer powered cycle the system.
Critical This event is generated when the BMC watchdog detects that the system has crashed (timer expired because no response was received from Host) and the action is set to power cycle.
The OS watchdog timer powered off the system.
Critical This event is generated when the BMC watchdog detects that the system has crashed (timer expired because no response

Event Message Severity Cause
was received from Host) and the action is set to power off.
The OS watchdog timer expired.
Critical This event is generated when the BMC watchdog timer expires and no action is set.
The memory modules can be configured in different ways in particular systems. These messages monitor the status, warning, and configuration information about the memory modules in the system.
Table 12. Memory Events
Event Message Severity Cause
Memory RAID redundancy degraded.
Memory RAID redundancy lost.
Critical This event is generated when redundancy is lost in a RAID- configured memory configuration.
Memory RAID redundancy regained.
Information This event is generated when the redundancy lost or degraded earlier is regained in a RAID- configured memory configuration.
Memory Mirrored redundancy degraded.
Memory Mirrored redundancy lost.
Critical This event is generated when redundancy is lost in a mirrored memory configuration.
Memory Mirrored redundancy regained.
Information This event is generated when the redundancy lost or degraded earlier is regained in a mirrored memory configuration.
Memory Spared redundancy degraded.
Memory Spared redundancy lost.
Critical This event is generated when redundancy is lost in a spared memory configuration.

Event Message Severity Cause
Memory Spared redundancy regained.
Information This event is generated when the redundancy lost or degraded earlier is regained in a spared memory configuration.
Memory RAID is redundant. Information This event is generated when the memory redundancy mode has change to RAID redundant.
Memory RAID redundancy is lost. Check memory device at location(s) .
Critical This event is generated when redundancy is lost in a RAID- configured memory configuration.
Memory RAID redundancy is degraded. Check memory device at location(s) .
Memory is not redundant. Information This event is generated when the memory redundancy mode has change to nonredundant.
Memory mirror is redundant.
Information This event is generated when the memory redundancy mode has change to mirror redundant.
Memory mirror redundancy is lost. Check memory device at location(s) .
Critical This event is generated when redundancy is lost in a mirror- configured memory configuration.
Memory mirror redundancy is degraded. Check memory device at location .
Memory spare is redundant.
Information This event is generated when the memory redundancy mode has change to spare redundant.
Memory spare redundancy is lost. Check memory device at location .
Critical This event is generated when redundancy is lost in a sparer- configured memory configuration.
Memory spare redundancy is degraded. Check memory device at location .

The hardware logs provide hardware status messages to the system management software. On particular systems, the subsequent hardware messages are not displayed when the log is full. These messages provide status and warning messages when the logs are full.
Table 13. Hardware Log Sensor Events
Event Message Severity Cause
Log full detected. Critical This event is generated when the SEL device detects that only one entry can be added to the SEL before it is full.
Log cleared. Information This event is generated when the SEL is cleared.
The drive event messages monitor the health of the drives in a system. These events are generated when there is a fault in the drives indicated.
Table 14. Drive Events
Event Message Severity Cause
Drive asserted fault state.
Critical This event is generated when the specified drive in the array is faulty.
Drive de- asserted fault state.
Information This event is generated when the specified drive recovers from a faulty condition.
Drive drive presence was asserted.
Information This event is generated when the drive is installed.
Drive predictive failure was asserted.
Drive predictive failure was deasserted.
Information This event is generated when the drive from earlier predictive failure is corrected.
Drive hot spare was asserted.
Drive hot spare was deasserted.
Information This event is generated when the drive is taken out of hot spare.
Drive consistency check in progress was asserted.

Event Message Severity Cause
Drive consistency check in progress was deasserted.
Information This event is generated when the consistency check of the drive is completed.
Drive in critical array was asserted.
Critical This event is generated when the drive is placed in critical array.
Drive in critical array was deasserted.
Information This event is generated when the drive is removed from critical array.
Drive in failed array was asserted.
Critical This event is generated when the drive is placed in the fail array.
Drive in failed array was deasserted.
Information This event is generated when the drive is removed from the fail array.
Drive rebuild in progress was asserted.
Information This event is generated when the drive is rebuilding.
Drive rebuild aborted was asserted.
Drive is installed.
Information This event is generated when the drive is installed.
Drive is removed.
Critical This event is generated when the drive is removed.
Fault detected on drive .
Critical This event is generated when the specified drive in the array is faulty.
The chassis intrusion messages are a security measure. Chassis intrusion alerts are generated when the system's chassis is opened. Alerts are sent to prevent unauthorized removal of parts from the chassis.
Table 15. Intrusion Events
Event Message Severity Cause
sensor detected an intrusion.
Critical This event is generated when the intrusion sensor detects an intrusion.
sensor returned to normal state.
Information This event is generated when the earlier intrusion has been corrected.

Event Message Severity Cause
sensor intrusion was asserted while system was ON.
Critical This event is generated when the intrusion sensor detects an intrusion while the system is on.
sensor intrusion was asserted while system was OFF.
Critical This event is generated when the intrusion sensor detects an intrusion while the system is off.
The chassis is open. Critical This event is generated when the intrusion sensor detects an intrusion.
The chassis is closed. Information This event is generated when the earlier intrusion has been corrected.
The chassis is open while the power is on.
Critical This event is generated when the intrusion sensor detects an intrusion while the system is on.
The chassis is closed while the power is on.
Information This event is generated when the earlier intrusion has been corrected while the power is on.
The chassis is open while the power is off.
Critical This event is generated when the intrusion sensor detects an intrusion while the system is off.
The chassis is closed while the power is off.
Information This event is generated when the earlier intrusion has been corrected while the power is off.
The BIOS-generated messages monitor the health and functionality of the chipsets, I/O channels, and other BIOS-related functions.
Table 16. BIOS Generated System Events
Event Message Severity Cause
System Event I/O channel chk.
Critical This event is generated when a critical interrupt is generated in the I/O Channel.
System Event PCI Parity Err.
Critical This event is generated when a parity error is detected on the PCI bus.
System Event Chipset Err. Critical This event is generated when a chip error is detected.

Event Message Severity Cause
System Event PCI System Err.
Information This event indicates historical data, and is generated when the system has crashed and recovered.
System Event PCI Fatal Err.
Critical This error is generated when a fatal error is detected on the PCI bus.
System Event PCIE Fatal Err.
Critical This error is generated when a fatal error is detected on the PCIE bus.
POST Err. Critical This event is generated when an error occurs during system boot. See the system documentation for more information on the error code.
POST fatal error # or .
Critical This event is generated when a fatal error occurs during system boot. For more information, see POST Code Errors.
Memory Spared redundancy lost.
Critical This event is generated when memory spare is no longer redundant.
Memory Mirrored redundancy lost.
Critical This event is generated when memory mirroring is no longer redundant.
Memory RAID redundancy lost.
Critical This event is generated when memory RAID is no longer redundant.
Err Reg Pointer OEM Diagnostic data event was asserted.
Information This event is generated when an OEM event occurs. OEM events can be used by the service team to better understand the cause of the failure.
System Board PFault Fail Safe state asserted.
Critical This event is generated when the system board voltages are not at normal levels.
System Board PFault Fail Safe state deasserted
Information This event is generated when earlier PFault Fail Safe system voltages return to a normal level.
Memory Add (BANK# DIMM#) presence was asserted.
Information This event is generated when memory is added to the system.

Event Message Severity Cause
Memory Removed (BANK# DIMM#) presence was asserted.
Information This event is generated when memory is removed from the system.
Memory Cfg Err configuration error (BANK# DIMM#) was asserted.
Critical This event is generated when memory configuration is incorrect for the system.
Mem Redun Gain redundancy regained.
Information This event is generated when memory redundancy is regained.
Mem ECC Warning transition to non- critical from OK.
Mem ECC Warning transition to critical from less severe.
Critical This event is generated when correctable ECC errors reach a critical rate.
Mem CRC Err transition to non-recoverable.
Critical This event is generated when CRC errors enter a non- recoverable state.
Mem Fatal SB CRC uncorrectable ECC was asserted.
Critical This event is generated while storing CRC errors to memory.
Mem Fatal NB CRC uncorrectable ECC was asserted.
Critical This event is generated while removing CRC errors from memory.
Mem Overtemp critical over temperature was asserted.
Critical This event is generated when system memory reaches critical temperature.
USB Over-current transition to non- recoverable
Critical This event is generated when the USB exceeds a predefined current level.
Hdwr version err hardware incompatibility (BMC/ iDRAC Firmware and CPU mismatch) was asserted.
Critical This event is generated when there is a mismatch between the BMC and iDRAC firmware and the processor in use or vice versa.
Hdwr version err hardware incompatibility (BMC/ iDRAC Firmware and CPU mismatch) was deasserted.
Information This event is generated when an earlier mismatch between the BMC and iDRAC firmware and the processor is corrected.

Event Message Severity Cause
SBE Log Disabled correctable memory error logging disabled was asserted.
Critical This event is generated when the ECC single bit error rate is exceeded.
CPU Protocol Err transition to non- recoverable.
Critical This event is generated when the processor protocol enters a non- recoverable state.
CPU Bus PERR transition to non-recoverable.
Critical This event is generated when the processor bus PERR enters a non-recoverable state.
CPU Init Err transition to non-recoverable.
Critical This event is generated when the processor initialization enters a non-recoverable state.
CPU Machine Chk transition to non- recoverable.
Critical This event is generated when the processor machine check enters a non-recoverable state.
Logging Disabled all event logging disabled was asserted.
Critical This event is generated when all event logging is disabled.
LinkT/FlexAddr: Link Tuning sensor, device option ROM failed to support link tuning or flex address (Mezz XX) was asserted
Critical This event is generated when the PCI device option ROM for a NIC does not support link tuning or the Flex addressing feature.
LinkT/FlexAddr: Link Tuning sensor, failed to program virtual MAC address () was asserted.
Critical This event is generated when BIOS fails to program virtual MAC address on the given NIC device.
Critical This event is generated in association with a CPU IERR and indicates the PCI/PCIe device that caused the CPU IERR.
Unknown system event sensor unknown system hardware failure was asserted.
Critical This event is generated when an unknown hardware failure is detected.

Event Message Severity Cause
An I/O channel check error was detected.
Critical This event is generated when a critical interrupt is generated in the I/O Channel.
A PCI parity error was detected on a component at bus device function .
Critical This event is generated when a parity error is detected on the PCI bus.
A PCI parity error was detected on a component at slot .
Critical This event is generated when a parity error is detected on the PCI bus.
A PCI system error was detected on a component at bus device function .
Critical This is generated when the system has crashed and recovered.
A PCI system error was detected on a component at slot .
Critical This is generated when the system has crashed and recovered.
A bus correctable error was detected on a component at bus device function .
Critical This is generated when the system has detected bus correctable errors.
A bus correctable error was detected on a component at slot .
Critical This is generated when the system has detected bus correctable errors.
A bus uncorrectable error was detected on a component at bus device function number>.
Critical This is generated when the system has detected bus uncorrectable errors.
A bus uncorrectable error was detected on a component at slot .
Critical This is generated when the system has detected bus uncorrectable errors.
A fatal error was detected on a component at bus device function .
Critical This error is generated when a fatal error is detected on the PCI bus.

Event Message Severity Cause
A fatal error was detected on a component at slot .
Critical This error is generated when a fatal error is detected on the PCI bus.
A fatal IO error detected on a component at bus device function .
Critical This error is generated when a fatal IO error is detected.
A fatal IO error detected on a component at slot .
Critical This error is generated when a fatal IO error is detected.
A non-fatal PCIe error detected on a component at bus device function .
A non-fatal PCIe error detected on a component at slot .
A non-fatal IO error detected on a component at bus device function .
Memory device was added at location .
Information This event is generated when memory is added to the system.
Memory device is removed from location .
Information This event is generated when memory is removed from the system.
Unsupported memory configuration; check memory device at location .
Critical This event is generated when memory configuration is incorrect for the system.
Correctable memory error rate exceeded for .
Correctable memory error rate exceeded for .
Critical This event is generated when correctable ECC errors reach a critical rate.
Memory device at location is overheating.
Critical This event is generated when system memory reaches critical temperature.

Event Message Severity Cause
An OEM diagnostic event occurred.
Information This event is generated when an OEM event occurs. OEM events can be used by the service team to better understand the cause of the failure.
CPU protocol error detected.
Critical This event is generated when the processor protocol enters a non- recoverable state.
CPU bus parity error detected.
Critical This event is generated when the processor bus PERR enters a non-recoverable state.
CPU initialization error detected.
Critical This event is generated when the processor initialization enters a non-recoverable state.
CPU machine check error detected.
Critical This event is generated when the processor machine check enters a non-recoverable state.
All event logging is disabled.
Critical This event is generated when all event logging is disabled.
Logging is disabled. Critical This event is generated when the ECC single bit error rate is exceeded.
The system board fail- safe voltage is outside of range.
Critical This event is generated when the system board voltages are not at normal levels.
The system board fail- safe voltage is within range.
Information This event is generated when earlier Fail-Safe system voltages return to a normal level.
A hardware incompatibility detected between BMC/iDRAC firmware and CPU.
Critical This event is generated when there is a mismatch between the BMC and iDRAC firmware and the processor in use or vice versa.
A hardware incompatibility was corrected between BMC/ iDRAC firmware and CPU.
Information This event is generated when an earlier mismatch between the BMC and iDRAC firmware and the processor is corrected.
Device option ROM on embedded NIC failed to support Link Tuning or FlexAddress.
Critical This event is generated when the PCI device option ROM for a NIC does not support link tuning or the Flex addressing feature.

Event Message Severity Cause
Device option ROM on mezzanine card failed to support Link Tuning or FlexAddress.
Critical This event is generated when the PCI device option ROM for a NIC does not support link tuning or the Flex addressing feature.
Failed to program virtual MAC address on a component at bus device function .
Critical This event is generated when BIOS fails to program virtual MAC address on the given NIC device.
Failed to get Link Tuning or FlexAddress data from iDRAC.
Critical This event is generated when BIOS could not obtain virtual MAC address or Link Tuning data from iDRAC.
An unknown system hardware failure detected.
Critical This event is generated when an unknown hardware failure is detected.
POST fatal error
Critical This event is generated when a fatal error occurs during system boot. For more information, see POST Code Errors.
The following table lists the POST Code errors that are generated when a fatal error occurs during system boot.
Table 17. POST Code Table
Fatal Error Code Description Cause
80 No memory detected. This error code implies that no memory is installed.
81 Memory detected but is not configurable.
This error code indicates memory configuration error that could be a result of bad memory, mismatched memory or bad socket.
82 Memory configured but not usable.
This error code indicates memory sub-system failure.
83 System BIOS shadow failure. This error code indicates system BIOS shadow failure.
84 CMOS failure. This error code indicates that CMOS RAM is not working.

Fatal Error Code Description Cause
85 DMA controller failure. This error code indicates DMA controller failure.
86 Interrupt controller failure. This error code indicates interrupt controller failure.
87 Timer refresh failure. This error code indicates timer refresh failure.
88 Programmable interval timer error.
This error code indicates a programmable interval timer error.
89 Parity error. This error code indicates a parity error.
8A SIO failure. This error code indicates SIO failure.
8B Keyboard controller failure. This error code indicates keyboard controller failure.
8C SMI initialization failure. This error code indicates SMI initialization failure.
C0 Shutdown test failure. This error code indicates a shutdown test failure.
C1 POST Memory test failure. This error code indicates bad memory detection.
C2 RAC configuration failure. Check screen for the actual error message.
C3 CPU configuration failure. Check screen for the actual error message.
C4 Incorrect memory configuration. Memory population order not correct.
FE General failure after video. Check screen for the actual error message.

Table 18. Operating System Generated System Events
Information The operating system was shutdown/restarted normally.
OEM Event data record (after OS graceful shutdown/restart event)
Information Comment string accompanying an operating system shutdown/ restart.
Critical The operating system encountered a critical error and was stopped abnormally.
OEM Event data record (after OS bugcheck event)
Information Operating system bugcheck code and parameters.
A critical stop occurred during OS load.
Critical The operating system encountered a critical error and was stopped abnormally while loading.
A runtime critical stop occurred.
Critical The operating system encountered a critical error and was stopped abnormally.
An OS graceful stop occurred.
Information The operating system was stopped.
An OS graceful shut-down occurred.
Information The operating system was shut down normally.
The cable interconnect messages in the table are used for detecting errors in the hardware cabling.
Table 19. Cable Interconnect Events
Cable sensor Configuration error was asserted.
Critical This event is generated when the cable is not connected or is incorrectly connected.
Cable sensor Connection was asserted.
Information This event is generated when the earlier cable connection error was corrected.
The cable or interconnect is not
Critical This event is generated when the named cable or interconnect is
Description Severity Cause · Description Severity Cause

connected or is improperly connected.
not connected or is incorrectly connected.
The cable or interconnect is connected.
Information This event is generated when named cable or interconnect earlier cable or interconnect connection error was corrected.
Table 20. Battery Events
Failed was asserted
Critical This event is generated when the sensor detects a failed or missing battery.
Failed was deasserted
Information This event is generated when the earlier failed battery was corrected.
is low was asserted
is low was deasserted
Information This event is generated when the earlier low battery condition was corrected.
The battery is low.
The battery is operating normally.
Information This event is generated when an earlier battery condition was corrected.
The battery has failed.
Critical This event is generated when the sensor detects a failed or missing battery.
Description Severity Cause · Description Severity Cause

The power and performance events are used to detect degradation in system performance with change in power supply.
Table 21. Power And Performance Events
Normal This event is generated when system performance was restored.
Normal This event is generated when the system performance is restored.
Normal This event is generated when the system performance is restored.
Description Severity Cause

Critical This event is generated when a change in power supply degrades system performance.
Normal This event is generated when system performance was restored.
The system performance degraded.
The system performance degraded because of thermal protection.
The system performance degraded because cooling capacity has changed.
The system performance degraded because power capacity has changed.
The system performance degraded because of user- defined power capacity has changed.
The system halted because system power exceeds capacity.
Critical This event is generated when there is inefficient power for the system.
The system performance degraded because power exceeds capacity.
The system performance degraded because power draw exceeds the power threshold.
Critical This event is generated when system power is inefficient causing system performance to degrade.
The system performance restored
Information This event is generated when system performance was restored.
Description Severity Cause

The entity presence messages are used for detecting different hardware devices.
Table 22. Entity Presence Events
Information This event is generated when the device was detected.
presence was asserted
absent was asserted
Critical This event is generated when the device was not detected.
The is present.
Information This event is generated when the device was detected.
The is absent.
Critical This event is generated when the device was not detected.
The following table provides events related to hardware and software components like mezzanine cards, sensors, firmware etc. and compatibility issues.
Table 23. Miscellaneous Events
Critical This event is generated when the required module is removed.
Critical This event is generated when an incorrect Mezzanine card is installed for I/O fabric.
Critical This event is generated when an incorrect Mezzanine card is installed for I/O fabric.
Critical This event is generated when an incompatible hardware is detected.
Critical This event is generated when a hardware is incompatible with the firmware.
Description Severity Cause · Description Severity Cause

(BMC firmware) was asserted
Critical This event is generated when the CPU and firmware are not compatible.
LinkT/FlexAddr: Link Tuning sensor, failed to program virtual MAC address (Bus # Device # Function #) was asserted
Critical This event is generated when Flex address can be programmed for this device.
LinkT/FlexAddr: Link Tuning sensor, device option ROM failed to support link tuning or flex address (Mezz ) was asserted
Critical This event is generated when ROM does not support Flex address or link tuning.
LinkT/FlexAddr: Link Tuning sensor, failed to get link tuning or flex address data from BMC/ iDRAC was asserted
Critical This event is generated when link tuning or Flex address information is not obtained from BMC/iDRAC.
The is removed. Critical This event is generated when the device was removed.
The is inserted. Information This event is generated when the device was inserted or installed.
A fabric mismatch detected between IOM and mezzanine card .
Critical This event is generated when an incorrect Mezzanine card is installed for I/O fabric.
Hardware incompatibility detected with mezzanine card .
Critical This event is generated when an incorrect Mezzanine card is installed in the system.
Description Severity Cause

The QuickPath Interconnect (QPI) width degraded.
The QuickPath Interconnect (QPI) width regained.
Information This event is generated when the bus is operating at maximum speed or width.
BIOS detected an error configuring the Intel Trusted Execution Technology (TXT).
Critical This event is generated when TXT initialization failed.
Processor detected an error while performing an Intel Trusted Execution Technology (TXT) operation.
Critical This event is generated when TXT CPU microcode boot failed.
BIOS Authenticated Code Module detected an Intel Trusted Execution Technology (TXT) error during POST.
Critical This event is generated when TXT Post failed.
SINIT Authenticated Code Module detected an Intel Trusted Execution Technology (TXT) error at boot.
Critical This event is generated when the Authenticated Code Module detected a TXT initialization failure.
Intel Trusted Execution Technology (TXT) is operating correctly.
Information This event is generated when the TXT returned from a previous failure.
Failure detected on Removable Flash Media .
Critical This event is generated when the SD card module is installed but improperly configured or failed to initialize.
Removable Flash Media is write protected.
Internal Dual SD Module is redundant.
Information This event is generated when both SD cards are functioning properly.
Internal Dual SD Module redundancy is lost.
Critical This event is generated when either one of the SD cards or both the SD cards are not functioning properly.
Description Severity Cause