Copyright © 2014 Dell Inc. All rights reserved. This product is protected by U.S. and international copyright and intellectual property laws. Dell™ and the Dell logo are trademarks of Dell Inc. in the United States and/or other jurisdictions. All other marks and names mentioned herein may be trademarks of their respective companies.
Rev. A00
2014 - 09





Front-panel features and indicators

Figure 1. Front-panel features and indicators—2.5 inch hard-drive/SSD system

Figure 2. Front-panel features and indicators—1.8 inch SSD system

The sled has USB ports on the front which allow you to connect a USB diskette drive, USB flash drive, USB DVD/CD drive, keyboard, or mouse. The USB drives can be used to configure the sled.
To designate the USB diskette drive as the boot drive:
The USB device is displayed in the boot order setup screen only if it is attached to the system before you run the System Setup. You can also select the boot device by pressing during system start-up and selecting a boot device for the current boot sequence.
The hard-drive/SSD (Solid State Drives) indicators display different patterns as drive events occur in the system.



Figure 3. Hard-drive/SSD indicators
Drive-Status Indicator Pattern Condition
Blinks green two times per second Identifying drive or preparing for removal
Off Drive ready for insertion or removal
Blinks green, amber, and then turns off Drive predicted failure
Blinks amber four times per second Drive failed
Blinks green slowly Drive rebuilding
Steady green Drive online
Blinks green three seconds, amber three seconds, and off six seconds
Rebuild aborted


Figure 4. iDRAC Direct LED indicator
The table below displays iDRAC Direct activity when configuring iDRAC Direct by using the management port (USB XML Import).
The table below displays iDRAC Direct activity when configuring iDRAC Direct using your laptop and cable (Laptop Connect).
iDRAC Direct LED indicator pattern
Steady green for two seconds
Indicates that the system is connected.
Flashing green (on for two seconds and off for two seconds)
Indicates that the system connected is recognized.
Turns off Indicates that the system is unplugged.
Condition

The documentation matrix provides information about documents that you can refer to, for setting up and managing your system.
To... Refer to...
Set up your system and know the system technical specifications
Getting Started With Your System
Install the operating system Operating system documentation at dell.com/ operatingsystemmanuals
Get an overview of the Dell Systems Management offerings
Dell OpenManage Systems Management Overview Guide at dell.com/openmanagemanuals
Configure and log in to iDRAC, set up managed and management system, know the iDRAC features, and troubleshoot using iDRAC
Integrated Dell Remote Access Controller User's Guide at dell.com/esmmanuals
Know about the RACADM subcommands and supported RACADM interfaces
RACADM Command Line Reference Guide for iDRAC and CMC at dell.com/esmmanuals
Start, enable, and disable Lifecycle Controller, know the features, use, and troubleshoot Lifecycle Controller
Dell Lifecycle Controller User’s Guide at dell.com/ esmmanuals
Use Lifecycle Controller Remote Services Dell Lifecycle Controller Remote Services Quick Start Guide at dell.com/esmmanuals
Set up, use, and troubleshoot OpenManage Server Administrator
Dell OpenManage Server Administrator User’s Guide at dell.com/openmanagemanuals
Install, use and troubleshoot OpenManage Essentials
Dell OpenManage Essentials User’s Guide at dell.com/openmanagemanuals
Know the system features, remove and install system components, and troubleshoot components
Owner’s Manual at dell.com/poweredgemanuals
Know the enclosure features, remove and install enclosure components, and troubleshoot enclosure components
Enclosure Owner’s Manual at dell.com/ poweredgemanuals
Know the features of the storage controller cards, deploy the cards, and manage the storage subsystem
Storage controller documentation at dell.com/ storagecontrollermanuals
See the event and error messages generated by the system firmware and agents that monitor system components
Dell Event and Error Messages Reference Guide at dell.com/esmmanuals

Use the Quick Resource Locator (QRL) to get immediate access to system information and how-to videos. This can be done by visiting dell.com/QRL or by using your smartphone and a model specific Quick Resource (QR) code located on your Dell PowerEdge system. To try out the QR code, scan the following image.


After you receive your PowerEdge system, you must set up your system in the enclosure, install the operating system if it is not pre-installed, and set up and configure the system iDRAC IP address.
Alternatively, you can also turn on the sled by using:
You can set up the iDRAC IP address using one of the following interfaces:
You can configure iDRAC using one of the following interfaces:
Related Links · Installing the sled

For more information on setting up and configuring iDRAC, see the iDRAC User’s Guide at dell.com/ esmmanuals.
You can log in to iDRAC as an iDRAC user, a Microsoft Active Directory user, or a Lightweight Directory Access Protocol (LDAP) user. You can also log in using Single Sign-On or Smart Card. The default user name is root and password is calvin. For more information on logging in to iDRAC and iDRAC licenses, see the iDRAC User’s Guide at dell.com/esmmanuals
You can also access iDRAC using RACADM. For more information, see the RACADM Reference Guide for iDRAC and CMC available at dell.com/esmmanuals
You can install the supported operating system on the sled by using the following methods:
For information on the list of operating systems supported on your system, see the operating systems support matrix at dell.com/ossupport
To perform out-of-band systems management using iDRAC, you must configure iDRAC for remote accessibility, set up the management station and managed system, and configure the supported Web browsers. For more information, see the iDRAC User’s Guide at dell.com/esmmanuals
You can also remotely monitor and manage the sleds from a single workstation, using the Dell OpenManage Server Administrator (OMSA) software and OpenManage Essentials (OME) systems management console. For more information, see dell.com/openmanagemanuals
It is recommended that you download and install the latest BIOS, drivers, and systems management firmware on your system.
Ensure that you clear the web browser cache.
Steps 1. Go to dell.com/support/drivers

The drivers that are applicable to your selection are displayed.

The pre-operating system management applications for your PowerEdge system help you manage different settings and features of your system without booting to the operating system.
Your PowerEdge system has the following pre-operating system management applications:
The navigation keys can help you access the pre-operating system management applications.
Moves to the previous screen.
Moves to the next screen.
Up arrow Moves to the previous field.
Moves to the next field.
Enables you to type a value in the selected field (if applicable) or follow the link in the field.
Spacebar Expands or collapses a drop-down list, if applicable.
Moves to the next focus area.
Moves to the previous page until you view the main screen. Pressing in the main screen exits System BIOS/iDRAC Settings/Device Settings/Service Tag Settings and proceeds with system boot.
Displays the System Setup help.
Using System Setup, you can configure the BIOS settings, iDRAC settings, and device settings of your system.
You can access System Setup in two ways:
Key Description · · Down arrow

If your operating system begins to load before you press , allow the system to finish booting, and then restart your system and try again.
System BIOS Enables you to configure BIOS settings.
iDRAC Settings Enables you to configure iDRAC settings.
The iDRAC Settings utility is an interface to set up and configure the iDRAC parameters by using UEFI. You can enable or disable various iDRAC parameters by using the iDRAC Settings utility. For more information about this utility, see the Integrated Dell Remote Access Controller User’s Guide at dell.com/esmmanuals
Device Settings Enables you to configure device settings.
You can use the System BIOS screen to view BIOS settings as well as edit specific functions such as boot order, system password, setup password, setting RAID mode, and enabling or disabling USB ports. In the System Setup Main Menu, click System BIOS.
System Information Displays information about the system such as the system model name, BIOS version and Service Tag.
Memory Settings Displays information and options related to the installed memory.
Processor Settings Displays information and options related to the processor such as speed, cache size, and so on.
SATA Settings Displays options to enable or disable the integrated SATA controller and ports.
Boot Settings Displays options to specify the boot mode (BIOS or UEFI). Enables you to modify UEFI and BIOS boot settings.
Network Settings Displays options to change the network settings.
Integrated Devices Displays options to enable or disable integrated device controllers and ports, and to specify related features and options.
Option Description · Menu Item Description

Serial Communication Displays options to enable or disable the serial ports and specify related features and options.
System Profile Settings Displays options to change the processor power management settings, memory frequency, and so on.
System Security Displays options to configure the system security settings like, system password, setup password, TPM security, and so on. It also enables or disables support for the power and NMI buttons on the system.
Miscellaneous Settings Displays options to change the system date, time, and so on.
You can use the System Information screen to view system properties such as Service Tag, system model, and the BIOS version. You can view the System Information screen by clicking System Setup Main Menu → System BIOS → System Information.
System Model Name Displays the system model name.
System BIOS Version Displays the BIOS version installed on the system.
System Management Engine Version
Displays the current revision of the Management Engine firmware.
System Service Tag Displays the system Service Tag.
System Manufacturer Displays the name of the system manufacturer.
System Manufacturer Contact Information
Displays the contact information of the system manufacturer.
System CPLD Version Displays the current revision of the system CPLD firmware.
UEFI Compliance Version Displays the system firmware UEFI compliance level.
System Memory screen allows you to view all the memory settings as well as enable or disable specific memory functions such as system memory testing and node interleaving. In the System Setup Main Menu, click System BIOS → System Memory.
System Memory Size Displays the amount of memory installed in the system.
System Memory Type Displays the type of memory installed in the system.
System Memory Speed Displays the system memory speed.
System Memory Voltage Displays the system memory voltage.
Video Memory Displays the amount of video memory.
System Memory Testing Specifies whether system memory tests are run during system boot. Options are Enabled and Disabled. By default, the System Memory Testing option is set to Disabled.
Menu Item Description · Menu Item Description · Menu Item Description

Memory Operating Mode Specifies the memory operating mode. The options available are Optimizer Mode, Advanced ECC Mode, Mirror Mode, Spare Mode, Spare with Advanced ECC Mode, and Dell Fault Resilient Mode. By default, the Memory Operating Mode option is set to Optimizer Mode.
Node Interleaving If this field is Enabled, memory interleaving is supported if a symmetric memory configuration is installed. If Disabled, the system supports Non- Uniform Memory architecture (NUMA) (asymmetric) memory configurations. By default, Node Interleaving option is set to Disabled.
Snoop Mode Snoop Mode options available are Disabled, Home Snoop, Early Snoop, Cluster on Die. By default, the Snoop Mode option is set to Disabled. The field is only available when Node Interleaving is Disabled.
You can use the Processor Settings screen to view the processor settings and perform specific functions such as enabling virtualization technology, hardware prefetcher, and logical processor idling. You can view the Processor Settings screen by clicking System Setup Main Menu → System BIOS → Processor Settings.
Logical Processor Enables or disables the logical processors and displays the number of logical processors. If the Logical Processor option is set to Enabled, the BIOS displays all the logical processors. If this option is set to Disabled, the BIOS only displays one logical processor per core. By default, the Logical Processor option is set to Enabled.
Alternate RTID (Requestor Transaction ID) Setting
Enables you to allocate more RTIDs to the remote socket, thereby increasing cache performance between the sockets or easing work in normal mode for NUMA. By default, the Alternate RTID (Requestor Transaction ID) Setting is set to Disabled.
Virtualization Technology Enables or disables the additional hardware capabilities provided for virtualization. By default, the Virtualization Technology option is set to Enabled.
Address Translation Service (ATS)
Defines the Address Translation Cache (ATC) for devices to cache the DMA transactions. This field provides an interface to a chipset's Address Translation and Protection Table to translate DMA addresses to host addresses. By default, the option is set to Enabled.
Adjacent Cache Line Prefetch
Optimizes the system for applications that require high utilization of sequential memory access. By default, the Adjacent Cache Line Prefetch option is set to Enabled. You can disable this option for applications that require high utilization of random memory access.
Menu Item Description · Menu Item Description

Hardware Prefetcher Enables or disables the hardware prefetcher. By default, the Hardware Prefetcher option is set to Enabled.
DCU Streamer Prefetcher Allows you to enable or disable the Data Cache Unit (DCU) streamer prefetcher. By default, the DCU Streamer Prefetcher option is set to Enabled.
DCU IP Prefetcher Enables or disables the Data Cache Unit (DCU) IP prefetcher. By default, the DCU IP Prefetcher option is set to Enabled.
Execute Disable Enables or disables the execute disable memory protection technology. By default, the Execute Disable option is set to Enabled.
Logical Processor Idling Enables or disables the operating system capability to put logical processors in the idling state in order to reduce power consumption. By default, the option is set to Disabled.
Configurable TDP Allows reconfiguration of Thermal Design Power (TDP) to lower levels. TDP refers to the maximum amount of power the cooling system is required to dissipate.
X2Apic Mode Enables or disables the X2Apic mode.
Controls the turbo engagement. Enable this option only when System Profile is set to Performance.
Number of Cores per Processor
Controls the number of enabled cores in each processor. By default, the Number of Cores per Processor option is set to All.
Processor 64-bit Support Specifies if the processor(s) support 64-bit extensions.
Processor Core Speed Displays the maximum core frequency of the processor.
Family-Model-Stepping Displays the family, model and stepping of the processor as defined by Intel.
Brand Displays the brand name reported by the processor.
Level 2 Cache Displays the total L2 cache.
Level 3 Cache Displays the total L3 cache.
Number of Cores Displays the number of cores per processor.
You can use the SATA Settings screen to view the SATA settings of SATA devices and enable RAID on your system. You can view the SATA Settings screen by clicking System Setup Main Menu → System BIOS → SATA Settings.
Menu Item Description · Dell Controlled Turbo · Processor 1

Embedded SATA Enables the embedded SATA to be set to Off, ATA, AHCI, or RAID modes. By default, the Embedded SATA option is set to AHCI.
Security Freeze Lock Sends Security Freeze Lock command to the Embedded SATA drives during POST. This option is applicable only to ATA and AHCI mode.
Write Cache Enables or disables the command for Embedded SATA drives during POST.
Port A Sets the drive type of the selected device. For Embedded SATA settings in ATA mode, set this field to Auto to enable BIOS support. Set it to OFF to turn off BIOS support. For AHCI mode or RAID mode, BIOS always enables support.
Model Displays the drive model of the selected device.
Drive Type Displays the type of drive attached to the SATA port.
Capacity Displays the total capacity of the hard drive. The field is undefined for removable media devices such as optical drives.
Port B Sets the drive type of the selected device. For Embedded SATA settings in ATA mode, set this field to Auto to enable BIOS support. Set it to OFF to turn off BIOS support. For AHCI mode or RAID mode, BIOS always enables support.
Model Displays the drive model of the selected device.
Drive Type Displays the type of drive attached to the SATA port.
Capacity Displays the total capacity of the hard drive. The field is undefined for removable media devices such as optical drives.
Port C Sets the drive type of the selected device. For Embedded SATA settings in ATA mode, set this field to Auto to enable BIOS support. Set it to OFF to turn off BIOS support. For AHCI mode or RAID mode, BIOS always enables support.
Model Displays the drive model of the selected device.
Drive Type Displays the type of drive attached to the SATA port.
Capacity Displays the total capacity of the hard drive. The field is undefined for removable media devices such as optical drives.
Port D Sets the drive type of the selected device. For Embedded SATA settings in ATA mode, set this field to Auto to enable BIOS support. Set it to OFF to turn off BIOS support. For AHCI mode or RAID mode, BIOS always enables support.
Model Displays the drive model of the selected device.
Drive Type Displays the type of drive attached to the SATA port.
Capacity Displays the total capacity of the hard drive. The field is undefined for removable media devices such as optical drives.
Menu Item Description

Port E Sets the drive type of the selected device. For Embedded SATA settings in ATA mode, set this field to Auto to enable BIOS support. Set it to OFF to turn off BIOS support. For AHCI mode or RAID mode, BIOS always enables support.
Model Displays the drive model of the selected device.
Drive Type Displays the type of drive attached to the SATA port.
Capacity Displays the total capacity of the hard drive. The field is undefined for removable media devices such as optical drives.
Port F Sets the drive type of the selected device. For Embedded SATA settings in ATA mode, set this field to Auto to enable BIOS support. Set it to OFF to turn off BIOS support. For AHCI mode or RAID mode, BIOS always enables support.
Model Displays the drive model of the selected device.
Drive Type Displays the type of drive attached to the SATA port.
Capacity Displays the total capacity of the hard drive. The field is undefined for removable media devices such as optical drives.
Port G Sets the drive type of the selected device. For Embedded SATA settings in ATA mode, set this field to Auto to enable BIOS support. Set it to OFF to turn off BIOS support. For AHCI mode or RAID mode, BIOS always enables support.
Model Displays the drive model of the selected device.
Drive Type Displays the type of drive attached to the SATA port.
Capacity Displays the total capacity of the hard drive. The field is undefined for removable media devices such as optical drives.
Port H Sets the drive type of the selected device. For Embedded SATA settings in ATA mode, set this field to Auto to enable BIOS support. Set it to OFF to turn off BIOS support. For AHCI mode or RAID mode, BIOS always enables support.
Model Displays the drive model of the selected device.
Drive Type Displays the type of drive attached to the SATA port.
Capacity Displays the total capacity of the hard drive. The field is undefined for removable media devices such as optical drives.
Port I Sets the drive type of the selected device. For Embedded SATA settings in ATA mode, set this field to Auto to enable BIOS support. Set it to OFF to turn off BIOS support. For AHCI mode or RAID mode, BIOS always enables support.
Model Displays the drive model of the selected device.
Drive Type Displays the type of drive attached to the SATA port.
Menu Item Description

Capacity Displays the total capacity of the hard drive. The field is undefined for removable media devices such as optical drives.
Port J Sets the drive type of the selected device. For Embedded SATA settings in ATA mode, set this field to Auto to enable BIOS support. Set it to OFF to turn off BIOS support. For AHCI mode or RAID mode, BIOS always enables support.
Model Displays the drive model of the selected device.
Drive Type Displays the type of drive attached to the SATA port.
Capacity Displays the total capacity of the hard drive. The field is undefined for removable media devices such as optical drives.
You can use the Boot Settings screen to set the Boot mode to either BIOS or UEFI. It also allows you to specify the boot order. You can view the Boot Settings screen by clicking System Setup Main Menu → System BIOS → Boot Settings.
Boot Mode Enables you to set the boot mode of the system.
If the operating system supports UEFI, you can set this option to UEFI. Setting this field to BIOS allows compatibility with non-UEFI operating systems. By default, the Boot Mode option is set to BIOS.
Boot Sequence Retry Enables or disables the Boot Sequence Retry feature. If this field is enabled and the system fails to boot, the system reattempts the boot sequence after 30 seconds. By default, the Boot Sequence Retry option is set to Enabled.
Hard-Disk Failover Specifies which devices in the Hard-Disk Drive Sequence are attempted in the boot sequence. When the option is Disabled, only the first hard disk device in the list is attempted to boot. When set to Enabled, all hard disk devices are attempted in order, as listed in the Hard-Disk Drive Sequence. This option is not enabled for UEFI Boot Mode.
Boot Option Settings Configures the boot sequence and the boot devices.
You can use the Network Settings screen to modify PXE device settings. Network Settings are only available in UEFI boot mode. BIOS does not control network settings in the BIOS boot mode. For BIOS boot mode, the network settings are handled by the network controllers option ROM. You can view the Network Settings screen by clicking System Setup Main Menu → System BIOS → Network Settings.
Menu Item Description · Menu Item Description

PXE Device n (n = 1 to 4) Enables or disables the device. When enabled, a UEFI boot option is created for the device.
PXE Device n Settings (n = 1 to 4)
Allows you to control the configuration of the PXE device.
Integrated Devices screen allows you to view and configure the settings of all integrated devices including the video controller, integrated RAID controller, and the USB ports. In the System Setup Main Menu, click System BIOS → Integrated Devices.
USB 3.0 Setting Allows you to enable or disable the USB 3.0 support Enable this option only if your operating system support USB 3.0. Disabling this allows devices to operate at USB 2.0 speed. USB 3.0 is disabled by default
User Accessible USB Ports Allows you to enable or disable the USB ports. Selecting Only Back Ports On disables the front USB ports, selecting All Ports Off disables all USB ports. The USB keyboard and mouse operates during boot process in certain operating systems. After the boot process is complete, the USB keyboard and mouse does not work if the ports are disabled.
Internal USB Port Allows you to enable or disable the internal USB port.
Integrated RAID Controller Allows you to enable or disable the integrated RAID controller.
Integrated Network Card 1 Allows you to enable or disable the integrated network card.
I/OAT DMA Engine Allows you to enable or disable the I/OAT option Enable only if the hardware and software supports the feature.
Embedded Video Controller Allows you to enable or disable the Embedded Video Controller. By default, the embedded video controller is Enabled. Current state of Embedded Video Controller is Enabled. Current State of Embedded Video Controller is a read only field, indicating the current state for the Embedded Video Controller. If the Embedded Video Controller is the only display capability in the system (that is, no add-in graphics card is installed), then the Embedded Video Controller is automatically used as the primary display even if the Embedded Video Controller setting is Disabled.
SR-IOV Global Enable Allows you to enable or disable the BIOS configuration of Single Root I/O Virtualization (SR-IOV) devices. By default, the SR-IOV Global Enable option is set to Disabled.
OS Watchdog Timer If your system stops responding, this watchdog timer aids in the recovery of your operating system. When this field is set to Enabled, the operating system is allowed to initialize the timer. When is set to Disabled (the default), the timer will have no effect on the system.
Menu Item Description · Menu Item Description

Memory Mapped I/O above 4GB Allows you to enable support for PCIe devices that require large amounts of memory. By default, the option is set to Enabled.
You can use the Serial Communication screen to view the properties of the serial communication port. You can view the Serial Communication screen by clicking System Setup Main Menu → System BIOS → Serial Communication.
Serial Communication Selects serial communication devices (Serial Device 1 and Serial Device 2) in the BIOS. BIOS console redirection can also be enabled and the port address can be specified. By default, Serial Communication option is set to Auto.
Serial Port Address Enables you to set the port address for serial devices. By default, the Serial Port Address option is set to Serial Device 1=COM2, Serial Device 2=COM1
External Serial Connector You can associate the External Serial Connector to Serial Device 1, Serial Device 2, or the Remote Access Device using this field.
Failsafe Baud Rate Displays the failsafe baud rate for console redirection. The BIOS attempts to determine the baud rate automatically. This failsafe baud rate is used only if the attempt fails, and the value must not be changed. By default, the Failsafe Baud Rate option is set to 115200.
Remote Terminal Type Sets the remote console terminal type. By default, the Remote Terminal Type option is set to VT 100/VT 220.
Redirection After Boot Enables or disables the BIOS console redirection when the operating system is loaded. By default, the Redirection After Boot option is set to Enabled.
Menu Item Description · Menu Item Description

You can use the System Profile Settings screen to enable specific system performance settings such as power management. You can view the System Profile Settings screen by clicking System Setup Main Menu → System BIOS → System Profile Settings.
System Profile Sets the system profile. If you set the System Profile option to a mode other than Custom, the BIOS automatically sets the rest of the options. You can only change the rest of the options if the mode is set to Custom. By default, the System Profile option is set to Performance Per Watt Optimized (DAPC). DAPC is Dell Active Power Controller.
CPU Power Management Sets the CPU power management. By default, the CPU Power Management option is set to System DBPM (DAPC). DBPM is Demand- Based Power Management.
Memory Frequency Sets the speed of the system memory. You can select Maximum Performance, Maximum Reliability, or a specific speed.
Turbo Boost Enables or disables the processor to operate in turbo boost mode. By default, the Turbo Boost option is set to Enabled.
Energy Efficient Turbo Enables or disables the Energy Efficient Turbo. Energy Efficient Turbo (EET) is a mode of operation where a processor’s core frequency is adjusted within the turbo range based on workload.
C1E Enables or disables the processor to switch to a minimum performance state when it is idle. By default, the C1E option is set to Enabled.
C States Enables or disables the processor to operate in all available power states. By default, the C States option is set to Enabled.
Collaborative CPU Performance Control
Enables or disables the CPU power management. When set to Enabled, the CPU power management is controlled by the OS DBPM and the System DBPM (DAPC). By default, the option is set to Disabled.
Memory Patrol Scrub Sets the memory patrol scrub frequency. By default, the Memory Patrol Scrub option is set to Standard.
Memory Refresh Rate Sets the memory refresh rate to either 1x or 2x. By default, the Memory Refresh Rate option is set to 1x.
Uncore Frequency Selects the Processor Uncore Frequency. Dynamic mode allows the processor to optimize power resources across the cores and uncore during runtime. The optimization of the uncore frequency to either save power or optimize performance is influenced by the setting of the Energy Efficiency Policy.
Energy Efficient Policy Enables you to selects the Energy Efficient Policy. The CPU uses the setting to manipulate the internal behavior of the processor and determines whether to target higher performance or better power savings.
Menu Item Description

Number of Turbo Boot Enabled Cores for Processor 1
Controls the number of turbo boost enabled cores for processor 1. By default, the maximum number of cores is enabled.
Monitor/Mwait Enables the Monitor/Mwait instructions in the processor. By default, the Monitor/Mwait option is set to Enabled for all system profiles, except Custom.
System Security screen allows you to perform specific functions such as setting the system password, setup password, and disabling the power button. In the System Setup Main Menu, click System BIOS → System Security Settings.
Intel AES-NI Improves the speed of applications by performing encryption and decryption using the Advanced Encryption Standard Instruction Set and is set to Enabled by default.
System Password Allows you to set the system password. This option is set to Enabled by default and is read-only if the password jumper is not installed in the system.
Setup Password Allows you to set the setup password. This option is read-only if the password jumper is not installed in the system.
Password Status Allows you to lock the system password. By default, the Password Status option is set to Unlocked.
Allows you to control the reporting mode of the Trusted Platform Module (TPM). By default, the TPM Security option is set to Off. You can only modify the TPM Status, TPM Activation , and Intel TXT fields if the TPM Status field is set to either On with Pre-boot Measurements or On without Pre-boot Measurements.
TPM Information Allows you to change the operational state of the TPM. By default, the TPM Activation option is set to No Change.
TPM Status Displays the TPM status.
Allows you to clear all the contents of the TPM. By default, the TPM Clear option is set to No.

Intel TXT Allows you to enable or disable Intel Trusted Execution Technology (TXT). To enable Intel TXT, Virtualization Technology must be enabled and TPM Security must be Enabled with Pre-boot measurements. By default, the Intel TXT option is set to Off.
Power Button Allows you to enable or disable the power button on the front of the system. By default, the Power Button option is set to Enabled.
AC Power Recovery Allows you to set how the system reacts after AC power is restored to the system. By default, the AC Power Recovery option is set to Last.
UEFI Variable Access Provides varying degrees of securing UEFI variables. When set to Standard (the default) UEFI variables are accessible in the Operating System per the UEFI specification. When set to Controlled, selected UEFI variables are protected in the environment and new UEFI boot entries are forced to be at the end of the current boot order.
Secure Boot Allows you to enable Secure Boot, where the BIOS authenticates each pre-boot image using the certificates in the Secure Boot Policy. Secure Boot is disabled by default.
Secure Boot Policy When Secure Boot policy is Standard, the BIOS uses the system manufacturer’s key and certificates to authenticate pre-boot images. When Secure Boot policy is Custom, the BIOS uses the user-defined key and certificates. Secure Boot policy is Standard by default.
Secure Boot Policy Summary
Allows you to view the list of certificates and hashes that secure boot uses to authenticated images.
Secure Boot Custom Policy Settings screen
Secure Boot Custom Policy Settings is displayed only when Secure Boot Policy is set to Custom. In the System Setup Main Menu, click System BIOS → System Security → Secure Boot Custom Policy Settings.
Platform Key Allows you to import, export, delete, or restore the platform key (PK).
Key Exchange Key Database Allows you to import, export, delete, or restore entries in the Key Exchange Key (KEK) Database
Allows you to import, export, delete, or restore entries in the Authorized Signature Database (db).
Allows you to import, export, delete, or restore entries in the Forbidden Signature Database (dbx).
You can use the Miscellaneous Settings screen to perform specific functions such as updating the asset tag, and changing the system date and time. You can view the Miscellaneous Settings screen by clicking System Setup Main Menu → System BIOS → Miscellaneous Settings.

System Time Enables you to set the time on the system.
System Date Enables you to set the date on the system.
Asset Tag Displays the asset tag and enables you to modify it for security and tracking purposes.
Keyboard NumLock Enables you to set whether the system boots with the NumLock enabled or disabled. By default the Keyboard NumLock is set to On.
F1/F2 Prompt on Error Enables or disables the F1/F2 prompt on error. By default, F1/F2 Prompt on Error is set to Enabled. The F1/F2 prompt also includes keyboard errors.
Load Legacy Video Option ROM Enables you to determine whether the system BIOS loads the legacy video (INT 10H) option ROM from the video controller. Selecting Enabled in the operating system does not support UEFI video output standards. This field is only for UEFI boot mode. You cannot set this to Enabled if UEFI Secure Boot mode is enabled.
In-System Characterization This option enables or disables In-System Characterization. By default, In-System Characterization is set to Disabled. The two other options are Enabled and Enabled - No Reboot.
When enabled, In-System Characterization (ISC) executes during POST upon detecting relevant change(s) in system configuration to optimize system power and performance. ISC takes about 20 seconds to execute, and system reset is required for ISC results to be applied. The Enabled - No Reboot option executes ISC and continues without applying ISC results until the next time system reset occurs. The Enabled option executes ISC and forces an immediate system reset so that ISC results can be applied. It takes the system longer to be ready due to the forced system reset. When disabled, ISC does not execute.
Menu Item Description

Boot Manager enables you to add, delete, and arrange boot options. You can also access System Setup and boot options without restarting the system.
The Boot Manager screen allows you to select boot options and diagnostic utilities.
If your operating system begins to load before you press , allow the system to finish booting, and then restart your system and try again.
Continue Normal Boot The system attempts to boot to devices starting with the first item in the boot order. If the boot attempt fails, the system continues with the next item in the boot order until the boot is successful or no more boot options are found.
One Shot Boot Menu Takes you to the boot menu where you can select a one time boot device to boot from.
Launch System Setup Enables you to access the System Setup.
Launch Lifecycle Controller Exits the Boot Manager and invokes the Lifecycle Controller program.
System Utilities Launches system utilities menu such as system diagnostics and UEFI shell.
Dell Lifecycle Controller allows you to perform useful tasks such as configuring BIOS and hardware settings, deploying an operating system, updating drivers, changing RAID settings, and saving hardware profiles. For more information about Dell Lifecycle Controller, see the documentation at dell.com/ esmmanuals.
You may have to change the boot order if you want to boot from a USB key or an optical drive. The instructions given below may vary if you have selected BIOS for Boot Mode.
Menu Item Description

System Setup enables you to specify the boot mode for installing your operating system:
You must select the boot mode in the Boot Mode field of the Boot Settings screen of System Setup. Once you specify the boot mode, the system boots in the specified boot mode, proceed to install your operating system from that mode. Thereafter, you must boot the system in the same boot mode (BIOS or UEFI) to access the installed operating system.
You can assign a new System Password and/or Setup Password or change an existing System Password and/or Setup Password only when the password jumper setting is enabled and Password Status is Unlocked. If the Password Status is Locked, you cannot change the System Password and/or Setup Password.
If the password jumper setting is disabled, the existing System Password and Setup Password is deleted and you need not provide the system password to boot the system.
Steps 1. To enter System Setup, press immediately after a power-on or reboot.
The System BIOS screen is displayed.
The System Security screen is displayed.
Use the following guidelines to assign the system password:

A message prompts you to re-enter the system password.
A message prompts you to re-enter the setup password.
When Password Status is Locked, type the password and press when prompted at reboot.
If an incorrect system password is entered, the system displays a message and prompts you to re-enter your password. You have three attempts to enter the correct password. After the third unsuccessful attempt, the system displays an error message that the system has halted and must be powered down.
Even after you shut down and restart the system, the error message is displayed until the correct password is entered.
Prerequisites Ensure that the Password jumper is set to enabled and the Password Status is set to Unlocked before attempting to delete or change the existing System and/or Setup password. You cannot delete or change an existing System or Setup password if the Password Status is Locked.
The System BIOS screen is displayed.
The System Security screen is displayed.
Steps · Next steps · Steps

If Setup Password is Enabled, enter the correct setup password before modifying most of the System Setup options.
If you do not enter the correct password in three attempts, the system displays the message
Incorrect Password! Number of unsuccessful password attempts: System Halted! Must power down.
Even after you shut down and restart the system, the error message is displayed until the correct password is entered. The following options are exceptions:
The Dell Lifecycle Controller provides advanced embedded systems management throughout the server’s lifecycle. The Lifecycle Controller can be started during the boot sequence and can function independently of the operating system.
For more information about setting up the Lifecycle Controller, configuring hardware and firmware, and deploying the operating system, see the Lifecycle Controller documentation at dell.com/support/home
The iDRAC Settings utility is an interface to setup and configure the iDRAC parameters using UEFI. You can enable or disable various iDRAC parameters using the iDRAC Settings utility, for example:
For more information on using iDRAC, see the iDRAC User's Guide, at dell.com/esmmanuals

The iDRAC Settings page is displayed.

This section provides information on installing and removing the sled components. For information on installing and removing the enclosure components, see the enclosure Owner's Manual at dell.com/ poweredgemanuals.
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
You may need the following items to perform the procedures in this section:

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Steps 1. Press the release button on the sled handle to the unlock position.


Figure 5. Removing and installing the I/O connector cover


Figure 6. Removing and installing the sled
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Steps 1. If you are installing a new sled, remove the plastic cover from the I/O connector(s) and save for future use.

The sled handle rotates toward the enclosure as the sled slides into the enclosure.
Turn on the sled.

Figure 7. Inside the sled
Next steps

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Pressing the release latches, hold both the edges of the cooling shroud and lift it up and away from the system.

Figure 8. Removing and installing a cooling shroud
Steps · Next steps

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Pressing the release latches, lower the cooling shroud into the system until the tabs on the sides of the release latches engage with the slots on the sled chassis.
Next steps Follow the procedure listed in After working inside your system.
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Hold the processor/DIMM blank by its edges and lift it away from the system.
Steps · Steps


Figure 9. Removing and installing a processor/DIMM blank
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Next steps

Steps 1. Align the standoffs on the processor/DIMM blank with the heat sink retention screws on the system board.
Your system supports DDR4 registered DIMMs (RDIMMs) and load reduced DIMMs (LRDIMMs). It supports DDR4 voltage specifications.
Memory bus operating frequency can be 2133 MT/s, 1866 MT/s, 1600 MT/s, or 1333 MT/s depending on:
The system contains 24 memory sockets split into two sets of 12 sockets, one set per processor. Each 12- socket set is organized into four channels. In each channel, the release levers of the first socket are marked white, the second socket black, and the third socket green.
The following table shows the memory populations and operating frequencies for the supported configurations.
Table 1. Memory population — operating frequency for supported configuration
DIMM Type DIMMs Populated Per Channel
Maximum DIMM Rank Per Channel
MT/s) For 1.2 V
2133, 1866, 1600, 1333
2 2133, 1866, 1600, 1333
2133, 1866, 1600, 1333
3 1866, 1600, 1333
LRDIMM 1 2133, 1866, 1600, 1333 Quad rank

DIMM Type DIMMs Populated Per Channel
Maximum DIMM Rank Per Channel
MT/s) For 1.2 V
2 2133, 1866, 1600, 1333 Quad rank
3 1866, 1600, 1333 Quad rank

Figure 10. Memory socket locations
Memory channels are organized as follows:
Operating Frequency (in

Your system supports Flexible Memory Configuration, enabling the system to be configured and run in any valid chipset architectural configuration. The following are the recommended guidelines for best performance:
Table 2. Heat sink — processor configurations
Processor Type (in Watts)
Reliability, Availability, and Serviceability (RAS) Features
Single processor 105 W, 120 W or 135 W
135 W (four cores, six cores, or eight cores), 145 W, or 105 acoustic configuration
8 (Three DIMMs in channel 0 and channel 2 and one DIMM in channel 1 and channel 3)
4 (One DIMM per channel)
Dual processor 105 W, 120 W or 135 W
135 W (four cores, six cores, or eight cores), 145 W, or 105 acoustic configuration
16 (Three DIMMs in channel 0 and channel 2 and one DIMM in channel 1 and channel 3)
8 (One DIMM per channel)

Four memory channels are allocated to each processor. The allowable configurations depend on the memory mode selected.
The following sections provide additional slot population guidelines for each mode.
Advanced ECC mode extends SDDC from x4 DRAM based DIMMs to both x4 and x8 DRAMs. This protects against single DRAM chip failures during normal operation.
Memory installation guidelines:
Memory optimized (independent channel) mode
This mode supports SDDC only for memory modules that use x4 device width and does not impose any specific slot population requirements.
In this mode, one rank per channel is reserved as a spare. If persistent correctable errors are detected on a rank, the data from this rank is copied to the spare rank and the failed rank is disabled.
With Memory Sparing enabled, the system memory available to the operating system is reduced by one rank per channel. For example, in a dual-processor configuration with sixteen 4 GB dual-rank DIMMs, the available system memory is: 3/4 (ranks/channel) × 16 (DIMMs) × 8 GB = 96 GB, and not 16 (DIMMs) × 8 GB = 128 GB.
Memory Mirroring offers the strongest DIMM reliability mode compared to all other modes, providing improved uncorrectable multi-bit failure protection. In a mirrored configuration, the total available system memory is one half of the total installed physical memory. Half of the installed memory is used to mirror the active DIMMs. In the event of an uncorrectable error, the system will switch over to the mirrored copy. This ensures SDDC and multi-bit protection.
Advanced ECC (Lockstep) · Memory Sparing · Memory Mirroring

Memory installation guidelines:
The following tables show sample memory configurations that follow the appropriate memory guidelines stated in this section.
Table 3. Memory configurations – single processor
System Capacity (in GB)
DIMM Size (in GB)
16 4 4 1R x8, 2133 MT/s A1, A2, A3, A4
24 4 6 1R x8, 2133 MT/s A1, A2, A3, A4, A5, A6
48 4 12 1R x8, 1600 MT/s A1, A2, A3, A4, A5, A6, A7, A8, A9, A10, A11, A12
48 8 6 2R x8, 2133 MT/s A1, A2, A3, A4, A5, A6
96 8 12 2R x8, 1600 MT/s A1, A2, A3, A4, A5, A6, A7, A8, A9, A10, A11, A12
96 16 6 2R x4, 2133 MT/s A1, A2, A3, A4, A5, A6
128 16 8 2R x4, 2133 MT/s A1, A2, A3, A4, A5, A6, A7, A8
144 16 and 8 10 2R x4, 1600 MT/s A1, A2, A3, A4, A5, A6, A7, A8, A9, A11
256 32 8 4R x4, 2133 MT/s A1, A2, A3, A4, A5, A6, A7, A8
384 32 12 4R x4, 1600 MT/s A1, A2, A3, A4, A5, A6, A7, A8, A9, A10, A11, A12
Number of DIMMs · Organization and Speed · DIMM Slot Population

Table 4. Memory configurations – two processors
System Capacity (in GB)
DIMM Size (in GB)
32 4 8 1R x8, 2133 MT/s A1, A2, A3, A4, B1, B2, B3, B4
64 4 16 1R x8, 2133 MT/s A1, A2, A3, A4, A5, A6, A7, A8, B1, B2, B3, B4, B5, B6, B7, B8
64 8 8 2R x8, 2133 MT/s A1, A2, A3, A4, B1, B2, B3, B4
96 4 24 1R x8, 1600 MT/s A1, A2, A3, A4, A5, A6, A7, A8, A9, A10, A11, A12, B1, B2, B3, B4, B5, B6, B7, B8, B9, B10, B11, B12
96 8 12 2R x8, 2133 MT/s A1, A2, A3, A4, A5, A6, B1, B2, B3, B4, B5, B6
128 8 16 2R x8, 2133 MT/s A1, A2, A3, A4, A5, A6, A7, A8, B1, B2, B3, B4, B5, B6, B7, B8
128 16 8 2R x4, 2133 MT/s A1, A2, A3, A4, B1, B2, B3, B4
160 8 20 2R x8, 1600 MT/s A1, A2, A3, A4, A5, A6, A7, A8, A9, A11, B1, B2, B3, B4, B5, B6, B7, B8, B9, B11
160 16 and 8 12 2R x4, 2133 MT/s A1, A2, A3, A4, A5, A6, B1, B2, B3, B4, B5, B6
192 8 24 2R x8, 1600 MT/s A1, A2, A3, A4, A5, A6, A7, A8, A9, A10, A11, A12, B1, B2, B3, B4, B5, B6, B7, B8, B9, B10, B11, B12
192 16 12 2R x4, 2133 MT/s A1, A2, A3, A4, A5, A6, B1, B2, B3, B4, B5, B6
Number of DIMMs · Organization and Speed · DIMM Slot Population

System Capacity (in GB)
DIMM Size (in GB)
256 16 16 2R x4, 2133 MT/s A1, A2, A3, A4, A5, A6, A7, A8, B1, B2, B3, B4, B5, B6, B7, B8
384 16 24 2R x4, 1600 MT/s A1, A2, A3, A4, A5, A6, A7, A8, A9, A10, A11, A12, B1, B2, B3, B4, B5, B6, B7, B8, B9, B10, B11, B12
512 32 16 4R x4, 2133 MT/s A1, A2, A3, A4, A5, A6, A7, A8, B1, B2, B3, B4, B5, B6, B7, B8
768 32 24 4R x4, 1600 MT/s A1, A2, A3, A4, A5, A6, A7, A8, A9, A10, A11, A12, B1, B2, B3, B4, B5, B6, B7, B8, B9, B10, B11, B12
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Steps 1. Locate the appropriate memory-module socket(s).
Number of DIMMs · Organization and Speed · DIMM Slot Population


Figure 11. Removing the memory module
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Next steps

Steps 1. Locate the appropriate memory-module socket.
The system should have already changed the value to reflect the newly installed memory.
The sled supports x16 Gen 3 PCIe mezzanine card, which provides an interface between the sled and the PCIe switches on the FX2s enclosure.
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Next steps

Steps 1. Open the PCIe mezzanine card retention latch by pressing the release tab on the retention latch.

Figure 12. Removing and installing a PCIe mezzanine card
Next steps

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Steps 1. Open the PCIe mezzanine card retention latch by pressing the release tab on the retention latch and lift the end of the latch.
The retention bracket on the side of the chassis latches onto the PCIe mezzanine card.
Next steps Follow the procedure listed in After working inside your system. Related Links
Removing the sled Installing the sled
The Internal Dual SD Module (IDSDM) card provides two SD card slots and a USB interface dedicated for the embedded hypervisor. This card offers the following features:
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

Steps 1. Locate the SD card slot on the internal dual SD module (IDSDM) card.


Figure 13. Replacing an SD card
The sled provides an internal USB connector for a USB flash memory key. The USB memory key can be used as a boot device, security key, or mass storage device. To use the internal USB connector, the Internal USB Port option must be enabled in the Integrated Devices screen of the System Setup.
To boot from the USB memory key, you must configure the USB memory key with a boot image, and then specify the USB memory key in the boot sequence in the System Setup. For information on creating
Next steps

a bootable file on the USB memory key, see the user documentation that accompanied the USB memory key.
Replacing the internal USB key
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Steps 1. Locate the USB connector/USB key.

Figure 14. Replacing the USB memory key
Next steps

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Steps 1. Remove the two screws securing the IDSDM card to the system board.

Figure 15. Removing and installing the IDSDM card

Replacing the internal USB key Replacing an SD card
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Steps 1. Align the following:
Replacing an SD card Replacing the internal USB key

rSPI (restore Serial Peripheral Interface) is a SPI flash device to store information about the system Service Tag, system configuration, or iDRAC license.
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Steps 1. Remove the two screws securing the rSPI card to the system board.

Figure 16. Removing and installing the rSPI card

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Steps 1. Align the two screw holes on the rSPI card with the standoffs on the system board.
Next steps Follow the procedure listed in After working inside your system.
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Steps 1. If installed, remove the SD vFlash card from the card slot.
Next steps


Figure 17. Replacing the SD vFlash card
Follow the procedure listed in After working inside your system.
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Next steps

Steps 1. Remove the two screws that secure the Network Daughter Card (NDC) to the system board.

Figure 18. Removing and installing the NDC
Next steps

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Steps 1. Align the following:
a. The slots on the card edge with the projection tabs on the plastic bracket covering the PCIe mezzanine card slots. b. Screw holes on the card with the standoffs on the system board.
Your system supports one or two Intel Xeon E5-2600 v3 product family processors.
Use the following procedure when:
Next steps

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Steps 1. Loosen the first screw that secures the heat sink to the system board.


Figure 19. Installing and removing a heat sink


Figure 20. Processor shield opening and closing lever sequence


Figure 21. Installing and removing a processor
Removing the cooling shroud
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Next steps · Related Links

Steps 1. Unlatch and rotate the socket-release levers 90 degrees upward and ensure that the socket-release lever is fully open.
a. Identify the pin-1 corner of the processor by locating the tiny gold triangle on one corner of the processor. Place this corner in the same corner of the ZIF socket identified by a corresponding triangle on the system board. b. Align the pin-1 corner of the processor with the pin-1 corner of the system board. c. Set the processor lightly in the socket.
Because the system uses a ZIF processor socket, do not use force. When the processor is positioned correctly, it drops down into the socket with minimal pressure. d. Close the processor shield. e. Rotate the socket-release lever 1 and lever 2 simultaneously until it is locked in position.
a. If applicable, remove the existing thermal grease from the heat sink using a clean lint-free cloth. b. Apply thermal grease on the top of the processor. Use the thermal-grease syringe included with
your processor kit to apply the grease in a thin spiral on the top of the processor as shown in the figure.


Figure 22. Applying thermal grease on the top of the processor
As the system boots, it detects the presence of the new processor and automatically changes the system configuration information in the System Setup.
Next steps

Installing the cooling shroud
Your system upports up to two 2.5 inch SAS/SATA/PCIe SSDs or SAS /SATA hard drives and eight 1.8 inch SATA SSDs. The hard drives/SSDs are supplied in special hot-swappable drive carriers that fit in the drive bays and these drives connect to the system board through the hard-drive backplane board.

Figure 23. Hard-drive/SSD bay numbering — 2.5 inch hard-drive/SSD system

Figure 24. SSD bay numbering — 1.8 inch SSD system
For single hard drive configuration, a hard-drive blank must be installed in the other drive bay to maintain proper airflow.
Related Links

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
When all indicators are off, the drive is ready for removal. See your operating system documentation for more information on taking the hard drive/SSD offline.

Figure 25. Removing and installing a hard drive/SSD
Steps · Next steps

Steps 1. Press the release button to open the hard-drive/SSD carrier handle.
The status LED indicator displays a steady green light if the drive is installed correctly. The drive carrier LED green indicator flashes as the drive rebuilds.
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Press the release latch and slide the hard-drive/SSD blank out of the hard-drive/SSD slot.
Related Links · Hard-drive/SSD indicator patterns · Steps


Figure 26. Removing and installing a 2.5 inch hard-drive/SSD blank

Figure 27. Removing and installing a 1.8 inch SSD blank
Next steps

Insert the hard-drive/SSD blank into the hard-drive/SSD slot until the release latch clicks into place.
If you need to service a hard drive/SSD, turn off the sled and before removing the hard drive/SSD wait for 30 seconds after the sled’s indicator turns off. Otherwise, the hard drive/SSD may not be recognized after it is reinstalled and the sled is powered on again.
The drive or device from which the system boots is determined by the boot order specified in the System Setup.
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Steps 1. Remove the four screws from the slide rails on the hard-drive/SSD carrier.
Steps


Figure 28. Removing and installing a 2.5 inch hard drive/SSD in a 2.5 inch hard-drive/SSD carrier
Install a new 2.5 inch hard drive/SSD in a 2.5 inch hard-drive/SSD carrier. See Installing a 2.5 inch hard drive/SSD in a 2.5 inch hard-drive/SSD carrier.
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Next steps

Steps 1. Slide the hard drive/SSD in to the hard-drive/SSD carrier.
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Pull the rails on the side of the carrier and lift the SSD out of the carrier.

Figure 29. Removing and installing a 1.8 inch SSD in a 1.8 inch SSD carrier
Install a 1.8 inch SSD in a 1.8 inch SSD carrier. See Installing a 1.8 inch SSD in a 1.8 inch SSD carrier.
Steps · Next steps

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Insert the SSD into the SSD carrier with the connector end of the SSD toward the back. When aligned correctly, the back of the SSD is flush with the back of the SSD carrier.
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Steps 1. Remove the two screws securing the hard-drive/SSD cage to the chassis.
Steps


Figure 30. Removing and installing a hard-drive/SSD cage
Removing a hard drive/SSD
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Next steps · Related Links

Steps 1. Align the slots on the sides of the hard-drive/SSD cage with the standoffs on the chassis.
Installing a hard drive/SSD
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Steps 1. Loosen the two retention screws securing the hard-drive/SSD backplane to the hard-drive/SSD cage.
Next steps · Related Links


Figure 31. Removing and installing the hard-drive/SSD backplane
Removing a hard drive/SSD
Next steps · Related Links

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Steps 1. Align the retention screws on the hard-drive/SSD backplane cable connector with the screw holes on the system board connector.
Installing the hard-drive/SSD cage Installing a hard drive/SSD
Next steps · Related Links

The PERC H730P slim card is supported only on systems with eight 1.8 inch SSDs and two processors.
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Steps 1. Loosen the two retention screws on the PERC H730P slim-card cable connector.


Figure 32. Removing and installing a PERC H730P slim card
Removing the cooling shroud
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Related Links

Steps 1. If installed, remove the PERC H730P slim card blank.
The PERC H730P slim card connects to the backplane connector.
Follow the procedure listed in After working inside your system.
Your system includes a dedicated expansion-card slot on the system board for a storage controller card that provides the integrated storage subsystem for your system’s hard drives. The storage controller card supports SSD/SAS/SATA hard drives.
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
a. hard drives/SSDs
b. hard-drive/SSD backplane
c. hard-drive/SSD cage
Next steps

Steps 1. Loosen the two retention screws on the hard-drive/SSD backplane cable connector and lift it away from the PCIe extender/storage controller card.

Figure 33. Removing and installing the PCIe extender/storage controller card
a. hard-drive/SSD cage
b. hard-drive/SSD backplane
c. hard drives/SSDs
Next steps

Removing a hard drive/SSD Removing the hard-drive/SSD backplane Removing the hard-drive/SSD cage
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Steps 1. Align the slots on the PCIe extender/storage controller card edge with the tabs on the support bracket.
a. hard drives/SSDs
b. hard-drive/SSD backplane
c. hard-drive/SSD cage
Installing a hard drive/SSD Installing the hard-drive/SSD backplane Installing the hard-drive/SSD cage
Related Links · Next steps · Related Links

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
a. hard drives/SSDs
b. cooling shroud
c. hard-drive/SSD backplane
d. hard-drive/SSD cage
e. PCIe mezzanine card
f. NDC
g. IDSDM/rSPI card
h. system board
Steps 1. Locate the system battery on the system.
a. Support the battery connector by pressing down firmly on the positive side of the connector. b. Hold the battery with the "+" facing up and slide it under the securing tabs at the positive side of
the connector.


Figure 34. Replacing the NVRAM backup battery
a. system board
b. IDSDM/rSPI card
c. NDC
d. PCIe mezzanine cards
e. hard-drive/SSD cage
f. hard-drive/SSD backplane
g. cooling shroud
h. hard drives/SSDs
Removing a hard drive/SSD Removing the cooling shroud Removing the hard-drive/SSD backplane Removing the hard-drive/SSD cage
Next steps · Related Links

Removing a PCIe mezzanine card Removing the Network Daughter Card Removing the IDSDM card Removing the rSPI card Removing the system board Installing the system board Installing the IDSDM card Installing the rSPI card Installing the Network Daughter Card Installing a PCIe mezzanine card Installing the hard-drive/SSD cage Installing the hard-drive/SSD backplane Installing the cooling shroud Installing a hard drive/SSD Removing the sled Installing the sled
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
CAUTION: If you are using Trusted Program Module (TPM) with an encryption key, you may be prompted to create a recovery key during program or System Setup. Be sure to create and safely store this recovery key. If you replace this system board, you must supply the recovery key when you restart your system or program before you can access the encrypted data on your hard drives.
a. processor(s) and heat sink(s)
b. memory modules
c. cooling shroud
d. hard drive/SSDs
e. hard-drive/SSD backplane

f. hard-drive/SSD cage
g. PCIe extender/storage controller card
h. PCIe mezzanine card
i. IDSDM/rSPI card
j. NDC
k. SD vFlash card
l. internal USB key
Steps 1. Remove the screws on the system board that secure the system board to the chassis


Figure 35. Removing and installing the system board
Removing a processor Removing memory modules Removing the cooling shroud Removing a hard drive/SSD Removing the hard-drive/SSD backplane Removing the hard-drive/SSD cage
Next steps · Related Links

Removing a PCIe mezzanine card Removing the Network Daughter Card Removing the IDSDM card Removing the rSPI card Replacing the SD vFlash card Replacing the internal USB key
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Steps 1. Hold the system board by its edges and align the USB connectors with the slots on the front wall of the chassis.
a. internal USB key
b. SD vFlash card
c. IDSDM/rSPI card
d. NDC/LOM riser card
e. PCIe mezzanine card
f. PCIe extender/storage controller card
g. hard-drive/SSD cage
h. hard-drive/SSD backplane
Next steps

i. hard drive(s)/SSD(s)
j. cooling shroud
k. memory modules
l. processor(s) and heat sink(s)
a. Use the Easy Restore feature to restore the Service Tag. For more information, see Restoring the Service Tag using Easy Restore.
b. If the Service Tag is not backed up in the backup flash device, enter the system Service Tag manually. For more information, see Entering the system Service Tag using System Setup.
c. Update the BIOS and iDRAC versions.
d. Re-enable the Trusted Platform Module (TPM). For more information, see Re-enabling the TPM for BitLocker users or Re-enabling the TPM for TXT users.
Replacing the internal USB key Replacing the SD vFlash card Installing the IDSDM card Installing the rSPI card Installing the Network Daughter Card Installing a PCIe mezzanine card Installing the PCIe extender/storage controller card Installing the hard-drive/SSD cage Installing the hard-drive/SSD backplane Installing a hard drive/SSD Installing the cooling shroud Installing memory modules Installing a processor
Restoring the Service Tag using Easy Restore
Use the Easy Restore feature if you do not know the Service Tag of your system. The Easy Restore feature allows you to restore your system’s Service Tag, license, UEFI configuration, and the system configuration data after replacing the system board. All data is backed up in a rSPI card automatically. If BIOS detects a new system board and the Service Tag in the rSPI card, BIOS prompts the user to restore the backup information.
If BIOS detects a new system board, and if the Service Tag is present in the rSPI card, BIOS displays the Service Tag, the status of the license, and the UEFI Diagnostics version.
Related Links

After the restore process is complete, BIOS prompts to restore the system configuration data.
After the restore process is complete, the system reboots.
Entering the system Service Tag using System Setup
If you know the system Service Tag, use the System Setup menu to enter the Service Tag.
For more information, see Integrated Dell Remote Access Controller User's Guide, at dell.com/ esmmanuals.
The Trusted Platform Module (TPM) is used to generate/store keys, protect/authenticate passwords, and create/store digital certificates. TPM can also be used to enable the BitLocker hard drive encryption feature in Windows Server.
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Steps 1. Align the edge connectors on the TPM with the slot on the TPM connector.


Figure 36. Installing the TPM
Initialize the TPM.
For more information on initializing the TPM, see http://technet.microsoft.com/en-us/library/ cc753140.aspx.
The TPM Status changes to Enabled, Activated.

Safety first—for you and your system
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Steps 1. Restart the sled:
a. Press the power button once to turn off the sled. b. Press the power button again to turn on the sled.
If no error messages appear, go to step 8.
If the amount of memory installed matches the system memory setting, go to step 8.

If the test fails, see Getting Help.
Removing the sled Installing the sled
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Steps 1. Run the appropriate controllers test and the hard drive tests in system diagnostics.
If the tests fail, go to step 3.
If the hard drive functions properly in the original bay, the drive carrier could have intermittent problems. Replace the drive carrier.
If the problem persists, see Getting Help.
Removing a hard drive/SSD Installing a hard drive/SSD Hard-drive/SSD indicator patterns
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Related Links · Related Links

Steps 1. Ensure that the sled is turned on.
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Steps 1. Run the appropriate tests in system diagnostics.
If the tests fail, go to step 3.
If the SSD functions properly in the original slot, the SSD carrier could have intermittent problems. Replace the SSD carrier.
If the problem persists, see Getting Help.
Hard-drive/SSD indicator patterns Removing a hard drive/SSD Installing a hard drive/SSD
Related Links

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
a. Remove the SD card from SD card slot 1. b. Remove the SD card present in SD card slot 2 and insert it into SD card slot 1. c. Install a new SD card in slot 2.
If the problem persists, see Getting Help.
Removing the sled Installing the sled Removing a hard drive/SSD
If the problem persists, see Getting Help.
Steps · Related Links

Removing the sled Installing the sled
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Steps 1. Turn off the sled using the operating system commands or the CMC.
If the tests fail, see Getting Help.
Removing the sled Installing the sled
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
The battery maintains the sled configuration, date, and time information in the NVRAM when the sled is turned off. You may need to replace the battery if an incorrect time or date is displayed during the boot routine.
You can operate the sled without a battery; however, the sled configuration information maintained by the battery in NVRAM is erased each time you remove power from the sled. Therefore, you must re-enter the system configuration information and reset the options each time the sled boots until you replace the battery.
Steps 1. Re-enter the time and date through the System Setup.
Related Links · Related Links

If the date and time are not correct in the System Setup, replace the battery. If the problem is not resolved by replacing the battery, see Getting Help.
Removing the sled Installing the sled Replacing the NVRAM backup battery
For a list of event and error messages generated by the system firmware and agents that monitor system components, see the Dell Event and Error Messages Reference Guide at dell.com/esmmanuals
A warning message alerts you to a possible problem and prompts you to respond before the system continues a task. For example, before you format a hard drive, a message warns you that you may lose all data on the hard drive. Warning messages usually interrupt the task and require you to respond by typing y (yes) or n (no).
The system diagnostic utilities may issue messages if you run diagnostic tests on your system. See Using System Diagnostics. for more information about system diagnostics.
The systems management software generates alert messages for your system. Alert messages include information, status, warning, and failure messages for drive, temperature, fan, and power conditions. For more information, see the systems management software documentation.
Related Links

If you experience a problem with your system, run the system diagnostics before contacting Dell for technical assistance. The purpose of running system diagnostics is to test your system hardware without requiring additional equipment or risking data loss. If you are unable to fix the problem yourself, service and support personnel can use the diagnostics results to help you solve the problem.
The embedded system diagnostics provides a set of options for particular device groups or devices allowing you to:
If a major component or device in the system does not operate properly, running the embedded system diagnostics may indicate component failure.
The embedded system diagnostics program is run from the Dell Lifecycle Controller.
Steps 1. As the system boots, press .
The ePSA Pre-boot System Assessment window is displayed, listing all devices detected in the system. The diagnostics starts executing the tests on all the detected devices.

See the documentation that came with the resource media for instructions.
To download the Dell diagnostics utility, go to dell.com/support
If diagnostics does not start automatically after the diagnostic media is booted, enter psa at the command prompt.
Configuration Displays the configuration and status information of all detected devices.
Results Displays the results of all tests that are executed.
System Health Provides the current overview of the system performance.
Event Log Displays a time-stamped log of the results of all tests run on the system. This is displayed if at least one event description is recorded.
For information about embedded system diagnostics, see the Dell Enhanced Pre-boot System Assessment User Guide at dell.com/support/home
Menu Description

System board jumper settings
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
For information on resetting the password jumper to disable a password, see Disabling a forgotten password.
Table 5. System Board Jumper settings
The password feature is enabled (pins 1–2).
The password feature is disabled (pins 2–3).
The configuration settings are retained at system boot (pins 2–3).
The configuration settings are cleared at the next system boot. (pins 1–2).
Jumper Setting Description · (default) · (default)


Figure 37. System board connectors
Table 6. System board connectors
1 BATTERY Connector for the 3.0 V coin cell battery
2 STORAGE Storage controller card connector
3 B3, B7, B11, B4, B8, B12 Memory module sockets (processor 2)
4 CPU2 Processor socket 2
5 J_PCIE_SEARAY PERC H730P Slim PERC card connector
6 CPU1 Processor socket 1
7 A1, A5, A9, A2, A6, A10 Memory module sockets (processor 1)
8 IDSDM/rSPI IDSDM/rSPI card connector
9 MEZZ1_FAB_C PCIe mezzanine card connector for the expansion bus
10 MEZZ2_FAB_B PCIe mezzanine card connector for the expansion bus
11 VFLASH SD vFlash card connector
12 bNDC Network daughter card connector
Item Connector Description

13 A3, A7, A11, A4, A8, A12 Memory module sockets (processor 1)
14 PWRD_EN, NVRAM_CLR System configuration jumpers
15 B1, B5, B9, B2, B6, B10 Memory module sockets (processor 2)
16 USB2 USB connector
17 USB1 USB connector
18 TPM TPM connector
19 J_BP Hard-drive backplane connector
The software security features of sled include a system password and a setup password. The password jumper enables these password features or disables them, and clears any password(s) currently in use.
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
When the sled is on, the power-on indicator is solid green. Allow the sled to finish booting.
The existing passwords are not disabled (erased) until the system boots with the password jumper on pins 1 and 2. However, before you assign a new system and/or setup password, you must reinstall the password jumper back to pins 2 and 3.
Removing the sled Installing the sled
Item Connector Description · Steps · Related Links

Height 4.03 cm (1.58 inch)
Width 21.1 cm (8.3 inch)
Depth 53.58 cm (21.09 inch)
Weight (maximum) 6.4 kg (14.11 lb)
Processor type One or two Intel Xeon processor E5-2600 v3 product family
Architecture 2133 MT/s, 1866 MT/s, 1600 MT/s, or 13333 MT/s DDR4 DIMMs
Memory module sockets Twenty-four 288-pin
RDIMMs 4 GB (single-rank), 8 GB (dual-rank), and 16 GB (dual-rank)
LRDIMMs 32 GB (quad-rank)
Minimum RAM 4 GB (single processor configuration)
Maximum RAM 768 GB (with 32 GB LRDIMMs)
Controller types PERC H730P, PERC H730, PERC H330, and PERC H730P slim card
Hard drives Up to two 2.5-inch, hot-swap SAS/SATA hard drives or SAS/SATA/PCIe SSDs
SSDs Up to eight 1.8-inch, hot-swap SATA SSDs
Optical drive External optional USB DVD

Flash drive Internal optional USB
Internal optional SD card
Optional vFlash card (with integrated iDRAC8 Enterprise)
USB One 4-pin, USB 2.0-compliant and one 4-pin, USB 3.0-compliant
SD Two internal SD cards dedicated for the hypervisor
One SD card dedicated for future vFlash support
PCIe mezzanine card slots One PCIe x16 Gen 3 slot that supports PCIe mezzanine card
Video type Matrox G200 VGA controller integrated with iDRAC
Video memory 2 GB shared with iDRAC application memory
NVRAM backup battery CR 2032 3.0 V lithium coin cell
Storage –40°C to 65°C (–40°F to 149°F)
Continuous operation (for altitude less than 950 m or 3117 ft)
10°C to 35°C (50°F to 95°F) with no direct sunlight on the equipment.
Fresh air For information on fresh air, see Expanded Operating Temperature section.
Maximum temperature gradient (operating and storage)

Storage 5% to 95% RH with 33°C (91°F) maximum dew point. Atmosphere must be non-condensing at all times.
Operating 10% to 80% Relative Humidity with 29°C (84.2°F) maximum dew point.
Operating 0.26 Grms at 5 Hz to 350 Hz (all operation orientations).
Storage 1.88 Grms at 10 Hz to 500 Hz for 15 min (all six sides tested).
Operating Six consecutively executed shock pulses in the positive and negative x, y, and z axes of 40 G for up to 2.3 ms.
Storage Six consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 71 G for up to 2 ms.
Operating 3048 m (10,000 ft).
Storage 12,000 m (39,370 ft).
Up to 35 °C (95 °F) Maximum temperature is reduced by 1°C/300 m (1°F/547 ft) above 950 m (3,117 ft).
35 °C to 40 °C (95 °F to 104 °F) Maximum temperature is reduced by 1°C/175 m (1°F/319 ft) above 950 m (3,117 ft).
40 °C to 45 °C (104 °F to 113 °F) Maximum temperature is reduced by 1°C/125 m (1°F/228 ft) above 950 m (3,117 ft).
NOTE: This section defines the limits to help avoid IT equipment damage and/or failure from particulates and gaseous contamination. If it is determined that levels of particulates or gaseous pollution are beyond the limits specified below and are the reason for the damage and/or failures to your equipment, it may be necessary for you to re-mediate the environmental conditions that are causing the damage and/or failures. Re-mediation of environmental conditions will be the responsibility of the customer.
Air filtration Data center air filtration as defined by ISO Class 8 per ISO 14644-1 with a 95% upper confidence limit.

Air must be free of conductive dust, zinc whiskers, or other conductive particles.
Copper coupon corrosion rate
Silver coupon corrosion rate
Continuous operation 5°C to 40°C at 5% to 85% RH with 29°C dew point.
For temperatures between 35°C and 40°C, de- rate maximum allowable temperature by 1°C per 175 m above 950 m (1°F per 319 ft).
< 1% of annual operating hours –5°C to 45°C at 5% to 90% RH with 29°C dew point.

For temperatures between 40°C and 45°C, de- rate maximum allowable temperature by 1°C per 125 m above 950 m (1°F per 228 ft).
– PCIe SSDs – Non Dell-qualified peripheral cards and/or peripheral cards greater than 25 W • When populating the sled slots in the FX2s enclosure with only PowerEdge FC630 sleds:
– Install 104 mm width heat sink for processors of less than 105 W. – If you install a sled with two processors in the FX2s enclosure, all sled slots in the enclosure must have PowerEdge FC630 sleds with the same configuration. However, vacant sled slots in the enclosure can be installed with sled blanks.
Expanded operating temperature

Contacting Dell
Dell provides several online and telephone-based support and service options. If you do not have an active Internet connection, you can find contact information on your purchase invoice, packing slip, bill, or Dell product catalog. Availability varies by country and product, and some services may not be available in your area. To contact Dell for sales, technical support, or customer-service issues:
a. Enter your system Service Tag in the Enter your Service Tag field. b. Click Submit.
The support page that lists the various support categories is displayed.
a. Select your product category. b. Select your product segment. c. Select your product.
The support page that lists the various support categories is displayed.
If you have feedback for this document, write to documentation_feedback@dell.com. Alternatively, you can click on the Feedback link in any of the Dell documentation pages, fill out the form, and click Submit to send your feedback.
Your system is identified by a unique Mini Express Service Tag and Service Tag number. The Mini Express Service Tag is found on the front of the system and Service Tag is found on the side of the system. This information is used by Dell to route support calls to the appropriate personnel.
Use the Quick Resource Locator (QRL) to get immediate access to system information and how-to videos. This can be done by visiting dell.com/QRL or by using your smartphone and a model specific Quick Resource (QR) code located on your Dell PowerEdge system. To try out the QR code, scan the following image.