DeVilbiss® Compressor/Nebulizer Instruction Guide Pulmo-Aide® Models 5650D, 5650I, 5650H, 5650P & 5650C PulmoMate® Models 4650D, 46502, 4650I, 4650AP, 4650L, 4650LD & 4650C Pulmo-Aide® LT Models 3650D, 3650I, 3650P & 3650T
DeVilbiss® Compresor/Nebulizador Guía de Instrucciones Pulmo-Aide® Modelos 5650D, 5650I, 5650H, 5650P y 5650C PulmoMate® Modelos 4650D, 46502, 4650I, 4650AP, 4650L, 4650LD y 4650C Pulmo-Aide® LT Modelos 3650D, 3650I, 3650P y 3650T
por, o bajo prescripción de, un médico. Hecho en EE.UU. Modelos 3650D, 4650D, 46502, 5650D, 5650H, 4650AP, 4650L, 4650LD y 3650T Calificado U.L. Modelos 4650C y 5650C Calificado CSA
Pulmo-Aide® Modèles 5650D, 5650I, 5650H, 5650P et 5650C PulmoMate® Modèles 4650D, 46502, 4650I, 4650AP, 4650L, 4650LD et 4650C Pulmo-Aide® LT Modèles 3650D, 3650I, 3650P et 3650T
nance d’un médecin. Fabriqué aux États-Unis. Modèles 3650D, 4650D, 46502, 5650D, 5650H, 4650AP, 4650L,
4650LD et 3650T Homologué U.L. Modèles 4650C et 5650C Homologué CSA



I m p o r t a n t S a f e g u a r d s
I m p o r t a n t S a f e g u a r d s 5
When using electrical products, especially when children are present, basic safety pre- cautions should always be followed. Read all instructions before using. Important information is highlighted by these terms:
the motor overheat. 5650–The unit will restart when the motor cools to an acceptable level. 4650/3650–Contact your qualified Sunrise provider for a replacement.
death. WARNING–Important safety information for hazards that might cause serious injury. CAUTION– Information for preventing damage to the product. NOTE– Information to which you should pay special attention.
If repair or replacement of the cord or plug is necessary, contact your qualified Sunrise provider.
This appliance has a polarized plug (one blade is wider than the other). As a safety feature, this plug will fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electri- cian. Do not attempt to defeat this safety feature.
READ ALL INSTRUCTIONS BEFORE USING.
This product should be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric current. This product is equipped with a cord having a grounding wire with a grounding plug. The plug must be plugged into an outlet that is properly installed and grounded.
To reduce the risk of burns, electrocution, fire or injury to persons:
1. A product should never be left unattended when plugged in. 2. Close supervision is necessary when this product is used by, on, or near children or invalids. 3. Use this product only for its intended use as described in this guide. Do not use attachments not recommended by the manufacturer. 4. Never operate this product if: a. It has a damaged power cord or plug. b. It is not working properly. c. It has been dropped or damaged. d. It has been dropped into water. Return the product to an authorized Sunrise service center for examination and repair. 5. Keep the power cord away from heated surfaces. 6. Never block the air openings of the product or place it on a soft surface, such as a bed or couch, where the air openings may be blocked. Keep the air open- ings free of lint, hair, and the like. 7. Never use while drowsy or asleep. 8. Never drop or insert any object into any opening or hose. 9. Do not use outdoors. This product is for household use only.
If repair or replacement of the cord or plug is necessary, contact your qualified Sunrise provider.
1. This unit is for use on a nominal 115V circuit and has a grounding plug. A tem- porary adapter, which looks like the adapter illustrated in Figures B and C, may be used to connect this plug to a 2-pole receptacle (as shown in Figure B) if a prop- erly grounded outlet is not available. The temporary adapter should be used only until a qualified electrician can install a properly grounded outlet (Figure A). The green colored rigid ear, lug, and the like extending from the adapter must be connected to a permanent ground such as a properly grounded outlet box cover. Whenever the adapter is used, it must be held in place by the metal screw.


I m p o r t a n t S a f e g u a r d s

Your doctor has prescribed a liquid medication to treat your respiratory condition. To best utilize this liquid medication, he has prescribed a DeVilbiss brand compressor/nebulizer. Your DeVilbiss compressor/nebulizer works to convert the med- ication to a high-quality mist of fine particles that penetrates deep into the lungs.
Be sure that you read and understand the information in this instruction guide. By fol- lowing these simple instructions and the advice of your physician, your compressor will become an effective addition to your therapeutic routine.
Statement of Intended Use
The DeVilbiss compressor/nebulizer is an AC powered air compressor that provides a source of compressed air for home health care use. The product is used in conjunction with a jet (pneumatic) nebulizer to convert liquid medication into an aerosol form with particles smaller than 5 microns diameter for inhalation into the patient's respira- tory tract for the treatment of respiratory disorders.
The target population for this device consists of both adult and pediatric patients suf- fering from, but not limited to asthma, cystic fibrosis, and chronic obstructive pul- monary disease. Further, additional applications for aerosolized medication are con- stantly under investigation and this device may be deemed suitable for such applica- tions as prescribed.
The intended environment for use of the product is in the patient's home on the order of a physician.

I m p o r t a n t P a r t s o f Y o u r N e b u l i z e r
H o w t o O p e r a t e Y o u r C o m p r e s s o r 9

densation (water build up) can occur in the internal hose of the compressor. It is recom- mended that the compressor be turned on and allowed to run for two (2) minutes before the tubing is attached to the air-outlet connector.
Nebulizer parts are not sold separately. Additional neb- ulizers (part #4650D-620) are available through your Sunrise provider.
6. Assemble clean nebulizer parts by placing baffle down in medication cup. Holding cup station- ary, screw on nebulizer cap. Add prescribed medication through the opening on cap using a medicine dropper or pre-measured dose contain- er (Fig. 4). 7. Assemble mouthpiece and t-piece (if applicable) and insert into the top of the nebulizer cap (Fig. 5). If using an aerosol mask, insert the bottom part of the mask directly into the top of the nebulizer cap. 8. Attach tubing to nebulizer air-inlet connector (Fig. 6).
Nebulizer parts are not sold separately. Additional neb- ulizers (Part #s 800D/800C/800G) are available through your Sunrise provider.
cleaned following cleaning instructions, or as rec- ommended by your physician or Sunrise provider.

C l e a n i n g 11
Disinfect Daily:
1. Using a clean container or bowl, soak items in three parts hot water to one part white vinegar for 30 minutes (Fig. 9) OR use a medical bacterial-germici- dal disinfectant available through your provider. For reusable nebulizer only, clean daily in dishwasher using top shelf. Be sure to follow manufacturer's instructions carefully. 2. With clean hands, remove items from disinfectant solution, rinse under hot tap water, and air dry on a clean paper towel. Store in a zip-lock bag.
after every five to seven treatment breaths. Remove mouthpiece from mouth and hold breath for at least five seconds (ten is better), then exhale slowly.
disposable nebulizer parts in an automatic dishwasher; doing so could cause damage.
To prevent possible risk of infection from contaminated cleaning solutions, always prepare fresh solution for each cleaning cycle and discard solution after each use.
All parts of the nebulizer, except tubing, should be cleaned according to the following instructions. Your physician and/or Sunrise provider may specify a certain cleaning procedure. If so, follow their recommendations.
depending on usage. Proper cleaning will also help extend the life of the nebu- lizer. Because it is disposable, we recommend that an extra nebulizer be kept on hand at all times. Sunrise also manufactures the DeVilbiss Reusable Nebulizer that is dishwasher safe and may be cleaned and reused for up to one year.
To prevent possible risk of infection from cont- aminated medication, cleaning of the nebulizer is recommended after each aerosol treatment. Disinfecting is recommended once a day.
Clean After Every Use:

S p e c i f i c a t i o n s 13
SPECIFICATIONS
Size 3650 Series 7.7" W x 4.1" H x 13" D
(19.5 cm x 10 cm x 33 cm) 4650 Series 7" W x 3.8" H x 13" D (18 cm x 10 cm x 33 cm) 5650 Series 10.1" W x 10.5" H x 6.5" D (26 cm x 27 cm x 17 cm) Weight 3650 Series 5.4 lbs. (2.45 kg)
4650 Series 5.3 lbs. (2.40 kg) 5650 Series 7.1 lbs. (3.2 kg) Electrical Requirements 3650D & 3650T 2.3 amps, 115 VAC 60 Hz
3650I 1.4 amps, 230 VAC 50 Hz 3650P 1.4 amps, 230 VAC 60 Hz 4650D, 46502, 4650AP, 4650L, 4650LD & 4650C 2.5 amps, 115 VAC 60Hz 4650I 1.4 amps, 230 VAC 50 Hz 5650D, 5650H & 5650C 1.3 amps, 115VAC 60Hz 5650I 0.8 amps, 230VAC 50Hz 5650P 0.8 amps, 230VAC 50/60Hz Sound Level 3650 Series 58 dBA
DeVilbiss air-inlet filter will result in compressor damage.
MAINTENANCE All maintenance must be performed by a qualified Sunrise provider or authorized ser- vice center.
4650 Series 53 dBA 5650 Series 51 dBA Power Consumption 3650D & 3650T 140 watts maximum
3650I & 3650P 160 watts maximum 4650D, 46502, 4650AP, 4650L, 4650LD & 4650C 140 watts max. 4650I 160 watts maximum 5650D, 5650H & 5650C 90 watts maximum 5650I & 5650P 100 watts maximum Max. Compressor Pressure 3650 & 4650 series 35 psig or greater*
5650 series 30 psig or greater* Compressor Free Air Flow (3650 & 4650) 8 lpm or greater*
(5650) 9 lpm or greater* Nebulizer Operating Pressure all models 11-16 psig Nebulizer Liter Flow all models 5-7 lpm Nebulizer Capacity all models 6 ml (cc) Nebulizer Nebulization Rate all models 0.15 ml/min or greater MMAD all models Less than 5 microns
*Conditions may vary based on altitude above sea level, barometric pressure changes.

FIVE-YEAR LIMITED WARRANTY ON COMPRESSOR PARTS
All DeVilbiss Compressor models are warranted to be free from defective workmanship and material for a period of five years from the date of purchase. Any defective part(s) will be repaired or replaced at Sunrise’s option if the unit has not been tampered with or used improperly during that period. Make certain that any malfunction is not due to inadequate cleaning or failure to follow the instructions. If repair is necessary, contact your authorized Sunrise provider or Sunrise Service Department at 800-333-4000 (814- 443-4881) (Canada 800-263-3390 or 905-660-2459) for instructions. NOTE— This war- ranty does not cover providing a loaner compressor, compensating for costs incurred in compressor rental while said unit is under repair, or costs for labor incurred in repair- ing or replacing defective part(s).
THERE IS NO OTHER EXPRESS WARRANTY. IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED TO THE DURATION OF THE EXPRESS LIMITED WARRANTY AND TO THE EXTENT PERMITTED BY LAW ANY AND ALL IMPLIED WARRANTIES ARE EXCLUDED. THIS IS THE EXCLUSIVE REMEDY AND LIABILITY FOR CONSEQUENTIAL AND INCIDENTAL DAMAGES UNDER ANY AND ALL WARRANTIES ARE EXCLUDED TO THE EXTENT EXCLUSION IS PERMITTED BY LAW. SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS, OR THE LIMITATION OR EXCLUSION OF CONSEQUENTIAL OR INCIDENTAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU.
This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
Thank you for choosing a DeVilbiss compressor/nebulizer. We want you to be a satis- fied customer. If you have any questions or comments, please send them to our address on the back of this manual.
Phone Purchase Date Serial #
Owners and our team usually reply within a day — and your question helps the next person too.