Page 1 · click to enlarge
Page 1

This limited warranty program is the only one that applies to this product, and it sets forth all the responsibilities of Vector Manufacturing, regarding this product. There is no other warranty, other than those described herein. This Vector Manufacturing product is warranted, to the original purchaser only, to be free of defects in materials and workmanship for five years from the date of purchase without additional charge. The warranty does not extend to subsequent purchasers or users. Manufacturer will not be responsible for any amount of damage in excess of the retail purchase price of the product under any circumstances. Incidental and consequential damages are specifically excluded from coverage under this warranty. This product is not intended for commercial use. This warranty does not apply to accessories or damage to units from misuse or incorrect installation. Misuse includes wiring or connecting to improper polarity power sources. RETURN/REPAIR POLICY: Defective products, other than accessories, may be returned postage prepaid to manufacturer. Any defective product, other than accessories, that is returned to manufacturer within 30 days of the date of purchase will be replaced free of charge. If such a product is returned more than 30 days but less than five years from the purchase date, manufacturer will repair the unit or, at its option, replace it free of charge. If the unit is repaired, new or reconditioned replacement parts may be used, at manufacturer’s option. A unit may be replaced with a new or reconditioned unit of the same or comparable design. The repaired or replaced unit will then be warranted under the terms of the remainder of the warranty period. The customer is responsible for the shipping charges on all returned items after 30 days. During the warranty period, manufacturer will be responsible for the return shipping charges. LIMITATIONS: This warranty does not cover accessories, bulbs, fuses and batteries, defects resulting from normal wear and tear (including chips, scratches, abrasions, discoloration or fading due to usage or exposure to sunlight), accidents, damage during shipping to our service facility, alterations, unauthorized use or repair, neglect, misuse, abuse, failure to follow instructions for care and maintenance, fire, flood and Acts of God. If your problem is not covered by this warranty, call Technical Support at (800) 618-5178 for general repair information and charges, if applicable. You may also contact us through our website at www.vectormfg.com STATE LAW RIGHTS: This warranty gives you specific legal rights. Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages, so the exclusions or limitations stated herein may not apply. This warranty gives the purchaser specific legal rights; other rights, which vary from state to state, may apply. TO REQUEST WARRANTY SERVICE FOR THIS PRODUCT: Contact Technical Support by telephone, fax or mail (see below). We suggest that you keep the original packaging in case you need to ship the unit. When returning a product, include your name, address, phone number, dated sales receipt (or copy) and a description of the reason for return and product serial number. After repairing or replacing the unit, we will make every effort to return it to you within four weeks. WARRANTY ACTIVATION: Please complete Warranty Activation Card and mail to Vector Manufacturing. Enter “VEC1089ABD” as Model and “15/10/2 Amp Smart Battery Charger” as Product Type. All Vector products must be registered within 30 days of purchase to activate this warranty. Mail the completed registration form, along with a copy of the original sales receipt to:

WARRANTY IS NON-TRANSFERABLE AND NON-REFUNDABLE.

  • ATTN.: CUSTOMER SERVICE 4140 SW 30th Ave., Ft. Lauderdale, FL 33312
  • TOLL FREE: (800) 618-5178
  • FAX: (954) 584-5556

FIVE YEAR LIMITED WARRANTY PROGRAM

© 2005 VECTOR MANUFACTURING MADE IN CHINA

BD050205

TO REDUCE THE RISK OF INJURY, USER MUST READ AND UNDERSTAND THIS INSTRUCTIONAL MANUAL. THIS MANUAL CONTAINS IMPORTANT INFORMATION REGARDING THE OPERATION AND WARRANTY OF THIS PRODUCT. PLEASE RETAIN FOR FUTURE REFERENCE.

IMPORTANT SAFETY INFORMATION, SAVE THESE INSTRUCTIONS

Vector VEC1089ABD — IMPORTANT SAFETY INFORMATION, SAVE THESE INSTRUCTIONS diagram (page 1)
Fig. 1

Fully Automatic Electronic Smart Battery Charger 15 Amp / 10 Amp / 2 Amp Charge Rates

Vector VEC1089ABD — IMPORTANT SAFETY INFORMATION, SAVE THESE INSTRUCTIONS diagram (page 1)
Fig. 2

USER’S MANUAL & WARRANTY INFORMATION

4140 S.W. 30th Ave., Ft. Lauderdale, FL 33312 U.S. Toll Free: (800) 618-5178

www.vectormfg.com

VEC1089ABD

Page 2 of the Vector VEC1089ABD user manual — GROUNDING MEANS
Page 2 · click to enlarge
Page 2

VEC1089ABD_Manual_042805 5/9/05 2:40 PM Page ii

WARNINGS 1. RISK OF EXPLOSIVE GAS MIXTURES — WORKING IN VICINITY OF A LEAD-ACID BATTERY IS DANGEROUS. BATTERIES GENERATE EXPLOSIVE GASES DURING NORMAL BATTERY OPERATION. FOR THIS REASON, IT IS OF UTMOST IMPORTANCE THAT EACH TIME BEFORE USING YOUR CHARGER, YOU READ THIS MANUAL AND FOLLOW THE INSTRUCTIONS EXACTLY. 2. To reduce risk of battery explosion, follow these instructions and those published by the battery manufacturer and manufacturer of any equipment you intend to use in vicinity of battery. Review cautionary markings on these products and on engine. 3. This equipment employs parts (switches, relays, etc.) that produce arcs or sparks. Therefore, if used in a garage or enclosed area, the unit MUST be placed not less than 18 inches above the floor. Battery Safety 1. Use of an attachment not recommended or sold by the battery charger manufacturer may result in a risk of fire, electric shock, or injury to persons. 2. To reduce risk of damage to electric plug and cord, pull by plug rather than cord when disconnecting charger. 3. An extension cord should not be used unless absolutely necessary. Use of an improper extension cord could result in a risk of fire and electric shock, and will void warranty. If an extension cord must be used, make sure: a. that pins on plug of extension cord are the same number, size, and shape as those of plug on charger; b. that extension cord is properly wired and in good electrical condition; and c. that wire size is AWG#16 (16 gauge) for 100 feet and AWG#14 for distances over 100 feet. 4. Do not operate charger with damaged cord or plug — take to a qualified technician for replacement of the plug or cord immediately. 5. Do not operate charger if it has received a sharp blow, been dropped, or otherwise damaged in any way; take it to a qualified service technician. 6. Do not disassemble charger; take it to a qualified service technician when service or repair is required. Incorrect re-assembly may result in a risk of electric shock or fire, and will void warranty. 7. To reduce risk of electric shock, unplug charger from outlet before attempting any maintenance or cleaning. Turning off controls without unplugging will not reduce this risk. 8. Do not expose charger to rain, snow or use when wet. Personal Safety 1. Another person should be within range of your voice or close enough to come to your aid when you work near a lead-acid battery. 2. Fresh water and soap should be nearby in case battery acid contacts skin, clothing, or eyes. 3. Wear complete eye protection and clothing protection. Avoid touching eyes while working with a battery. Acid, acid particles or corrosion may get into eyes. Immediately flood eye with cold water (Eye Wash Station) for at least 15 minutes and seek medical attention immediately. 4. If battery acid contacts skin or clothing, wash immediately with soap and water. If redness, pain or irritation occurs, seek immediate medical attention. 5. NEVER smoke or allow a spark or flame in vicinity of battery or engine. 6. Be extra cautious to reduce the risk of dropping a metal tool onto battery. This might cause sparks or short-circuit the battery or other electrical part, which can cause an explosion. 7. Remove personal metal items such as rings, bracelets, necklaces and watches when working with a lead-acid battery. A lead-acid battery can produce a short-circuit current high enough to cause a severe burn. 8. Use charger for charging a LEAD-ACID battery only. It is not intended to supply power to a low- voltage electrical system other than in a starter-motor application. Do not use the battery charger for charging dry-cell batteries that are commonly used with home appliances. These batteries may burst and cause injury to persons and damage property. 9. NEVER ATTEMPT TO CHARGE A FROZEN BATTERY. Power Cord Safety Charger should be grounded to reduce risk of electric shock. Charger is equipped with an AC cord having equipment-grounding conductor and a grounding plug. The plug must be plugged into a properly installed and grounded 110/120 volt AC outlet in accordance with all local codes and ordinances (see Figure 1A).

IMPORTANT SAFETY INSTRUCTIONS

If a properly grounded outlet is not available, a temporary adapter (like the adapter shown in Figure1B) may be used to connect this plug to a two-pole receptacle. The temporary adapter should be used ONLY until a properly grounded outlet can be installed by a qualified electrician. DANGER — Before using an adapter as illustrated, make certain that the center screw of outlet plate is grounded. The green-colored rigid ear or tab extending from adapter must be connected to a properly grounded outlet. MAKE CERTAIN IT IS GROUNDED. If necessary, replace original outlet cover plate screw with a longer screw that will secure adapter ground tab to outlet cover plate and connect to grounded outlet. WARNING NEVER alter AC cord or plug. If it will not fit, have a proper outlet installed by a qualified electrician. Improper connection may result in an electric shock. Note: Use of an adapter is not allowed in Canada. If a grounding type receptacle is not available, do not use this appliance until the proper outlet has been installed by a qualified electrician. Preparing to Charge 1. Determine voltage of battery to be charged by referring to the vehicle manual. 2. If it is necessary to remove battery from vehicle to charge, or to clean terminals, always remove grounded terminal from battery first. Make sure all accessories in the vehicle are off, so as not to cause an arc. 3. Clean battery terminals. Do not allow corrosion to come in contact with eyes. 4. Add distilled water in each cell until battery acid reaches level specified by battery manufacturer. This helps purge excessive gas from cells. Do not overfill. For a battery without cell caps (maintenance free), carefully follow manufacturer's charging instructions. 5. Study all battery manufacturer’s specific precautions, such as removing or not removing cell caps while charging, and recommended rates of charge. 6. Area around battery should be well ventilated while battery is being charged. Gas can be forcefully blown away by using a piece of cardboard or other nonmetallic material as a fan. 7. Make sure the initial charging rate does not exceed battery manufacturer’s requirement. Charger Location 1. Locate charger as far away from battery as cables permit. 2. NEVER place charger directly above battery being charged; gases from battery will corrode and damage charger. 3. NEVER allow battery acid to drip on charger when reading gravity or filling battery. 4. NEVER operate charger in a closed-in area or restrict ventilation in any way. 5. Marine batteries must be removed and charged on shore. 6. Do not set a battery on top of charger. DC Connection Precautions 1. Connect and disconnect DC output clamps only after removing AC cord from electric outlet. 2. Never allow clamps to touch each other. 3. Attach clamps to battery chassis as indicated in “Battery Installed in Vehicle” steps 5 and 6, and in “Battery Outside of Vehicle” steps 2, 4 and 5. Follow these steps when the battery is installed in a vehicle. A spark near the battery may cause an explosion. To reduce risk of a spark near the battery: 1. Position AC and DC cords to reduce risk of damage by hood, door, or moving engine part. 2. Stay clear of fan blades, belts, pulleys, and other parts that can cause injury to persons. 3. Check polarity of battery posts. POSITIVE (POS, P, +) battery post usually has larger diameter than NEGATIVE (NEG, N, –) post. 4. Determine which post of battery is grounded (connected) to the chassis. If NEGATIVE post is grounded to chassis (as in most vehicles), see 5. If POSITIVE post is grounded to the chassis, see 6.

ADAPTER (B) Figure 1A Figure 1B

Vector VEC1089ABD — ADAPTER (B) Figure 1A Figure 1B diagram (page 2)
Fig. 3 · ADAPTER (B) Figure 1A Figure 1B

GROUNDING PIN (A)

Vector VEC1089ABD — GROUNDING PIN (A) diagram (page 2)
Fig. 4

GROUNDING MEANS

METAL SCREW

Page 3 of the Vector VEC1089ABD user manual — IMPORTANT SAFETY INSTRUCTIONS
Page 3 · click to enlarge
Page 3
Page 3 of the Vector VEC1089ABD user manual — IMPORTANT SAFETY INSTRUCTIONS
Page 4 of the Vector VEC1089ABD user manual — OPERATION CODES
Page 4 · click to enlarge
Page 4

FUNCTION BUTTONS (FROM RIGHT TO LEFT): Battery Type — allows the user to select wet battery, gel battery or AGM battery. 2/10/15 Charge Rate Selector — allows the user to select the charge rate based on battery size. This selection and actual battery charge rate are monitored by the microprocessor and will stop charging if the rate is too fast or too slow for battery size or condition.

Vector VEC1089ABD — CONTROL PANEL diagram (page 4)
Fig. 5

CONTROL PANEL

Controls and Indicators

FEATURES

AC POWER INDICATOR - When connected to an AC outlet, digital display shows circulating pattern to indicate power is on. Disconnect charger after use. FAULT CODES F01 INTERNAL SHORTED CELL BATTERY - Cannot be charged. Have battery checked by certified auto service center. F05 OVERHEATED CONDITION - Disconnect charger and allow to cool for 30 min., check for ample ventilation. EXCESSIVE LOAD ON BATTERY WHILE CHARGING - Check load. F06 REVERSE POLARITY F01F05 F06REVERSE POLARITY F02BAD BATTERY CONNECTION - Check battery connection. BATTERY VOLTAGE TOO LOW TO ACCEPT CHARGE - Have battery checked by certified auto service center.F07ALTERNATOR OUTPUT IS OUT OF TYPICAL OPERATION RANGE F03INTERNAL OPEN CELL - Have battery checked by certified auto service center. SULFATED CONDITION - Battery needs to be reconditioned. See manual.OPERATION CODES BATTERY RECONDITIONING - (The letters DES will display for the first 3 seconds.) F04OVERTIME CONDITION - Battery will not accept a charge after 18 hours of continuous charging. Battery may have internal damage. Have battery checked by certified auto service center. BATTERY CHARGE RATE IS SET TOO LOW - Set charger to higher charge rate. See manual.000ALTERNATOR VOLTAGE CHECK CHARGER STANDBY FULBATTERY FULLY CHARGED
Vector VEC1089ABD — CONTROL PANEL diagram (page 4)
Fig. 6

DIGITAL READOUT CIRCULATING PATTERN

BUTTON (BELOW THE DIGITAL DISPLAY): Equalizing — a recessed button used to start the equalization process.

CONTROL PANEL LED INDICATORS: WET — lights when battery type selector is on WET battery type GEL — lights when battery type selector is on GEL battery type AGM — lights when battery type selector is on AGM battery type Float Charge — lights when automatic charge monitoring is active Alternator Good — lights when load or no load checks show the alternator is keeping up with the electrical load

AC POWER INDICATOR - When connected to an AC outlet, digital display shows circulating pattern to indicate power is on. Disconnect charger after use. FAULT CODES

INDICATORS: Large (.375”) 3-Character Digital Display in the upper left of the control panel indicates the various conditions and/or status codes: Status Codes are described in the following chart and on back of the charger.

Battery Voltage — enables a check that measures the battery voltage and displays it for 3 seconds. Battery Recond — improves performance of sulfated and aged batteries. Alternator Check — is a five-second check that measures the battery voltage. This check is repeated at various electrical load levels and the tests allow the user to determine if the alternator can keep up with the loads. It can indicate alternator voltage is out of typical operation voltage.

F01 INTERNAL SHORTED CELL BATTERY - Cannot be charged. Have battery checked by certified auto service center. EXCESSIVE LOAD ON BATTERY WHILE CHARGING - Check load. F02 BAD BATTERY CONNECTION - Check battery connection. BATTERY VOLTAGE TOO LOW TO ACCEPT CHARGE - Have battery checked by certified auto service center. F03 INTERNAL OPEN CELL - Have battery checked by certified auto service center. SULFATED CONDITION - Battery needs to be reconditioned. See manual. F04 OVERTIME CONDITION - Battery will not accept a charge after 18 hours of continuous charging. Battery may have internal damage. Have battery checked by certified auto service center. BATTERY CHARGE RATE IS SET TOO LOW - Set charger to higher charge rate. See manual.

BATTERY RECONDITIONING - (The letters DES will display for the first 3 seconds.) ALTERNATOR VOLTAGE CHECK 000 CHARGER STANDBY FUL BATTERY FULLY CHARGED

OPERATION CODES

F05 OVERHEATED CONDITION - Disconnect charger and allow to cool for 30 min., check for ample ventilation. F06 REVERSE POLARITY F07 ALTERNATOR OUTPUT IS OUT OF TYPICAL OPERATION RANGE

Page 5 of the Vector VEC1089ABD user manual — WARNING
Page 5 · click to enlarge
Page 5

1. Press Battery Type selector until desired battery type LED lights. Note: The default selection is “GEL” type battery. 2. Press 2/10/15 AMP button to begin charging at the 2 amp rate; the unit sounds a beep and the charging current LED lights. The charger starts charging at 2 amp rate automatically if 2/10/15 AMP button is not pressed within 3 minutes after applying AC power. Charger occasionally sounds a beep and displays “0.0” during self-test or charging stage changes. 3. Pressing the 2/10/15 AMP button again advances charging rate to 10 amps and pressing once more advances charging rate to 15 amps. (Pressing the button again will turn OFF the charger output and the Display will show “000”.) This selection and actual battery charge rate are monitored by the microprocessor and the unit will stop charging if the selected rate is too fast or too slow for battery size or condition. As the battery nears full charge capacity, the unit’s output will automatically drop to a lower charge rate.

If Digital Display shows “F02” and the Fault indicator lights, the connection to the battery terminals is bad. Follow the steps outlined in “Important Safety Instructions” at the front of this manual to disconnect, clean battery terminals, then reconnect. If Digital Display shows “F06”, the Red (Positive) and Black (Negative) clamps are incorrectly connected to battery terminals. Follow the steps outlined in “Important Safety Instructions” at the front of this manual to disconnect, then reconnect in correct polarity. Charging the Battery

Note: The only time the selected charge rate does not display at the full selected rate is when the battery is nearly full and charging at either step two or three. The display will show a reduced charge rate. To return to 2A, press the 2/10/15 AMP button. When the battery is fully charged, the charging complete and “FUL” is displayed on the Digital Display. WARNING

After charger clamps are correctly connected, plug in the charger to a 120 volt AC outlet. The charger will show a circulating pattern on the Digital Display, indicating power has been applied. Select the proper charge current rate based on battery size. Press the 2/10/15 AMP button and the charger will begin charging at 2 amps. Pressing the 2/10/15 AMP button again will advance the charge rate to 10 amps, and again to 15 amps. Pressing the switch again will turn OFF the charger output and the display will show “000”.

Ensure that all installation and operating instructions and safety precautions are understood and carefully followed by anyone installing or using the charger. Follow the steps outlined in “Important Safety Instructions” at the front of this manual. Charge Rate Selection

OPERATING INSTRUCTIONS

The frequency at which the equalization process needs to be run depends on the use of the battery. The more the battery is used, the more undercharged it becomes; thus the more frequently the battery should be equalized. 1. Do not use this mode on sealed or valve regulated batteries. This mode is only meant for wet (unsealed/vented) batteries. 2. Make sure there are no flammable sources near the recharging sight. 3. Wear safety glasses, gloves and protective clothing. 4. Remove battery from vehicle. MAKE SURE THAT THE BATTERY HAS GOOD VENTILATION. The process causes the release of hydrogen and oxygen. An accumulation of these gases presents a real danger of explosion. 5. Open the battery cap, if removable.

  • NEVER TRY TO EQUALIZE A GEL OR AGM CELL. THE RESULTING EXPLOSION COULD CAUSE PROPERTY DAMAGE, SERIOUS INJURY AND/OR DEATH.
  • Remove or disconnect the vehicle’s battery when equalizing.

Equalizing is the process by which the fluid in each of a battery’s cells is equalized. This process occurs after charging is complete.

Equalizing

If battery size is not known, charge at the 2 amp rate. DO NOT overcharge batteries.

Automatic Float Charging is ideal for maintaining a fully charged battery. 1. Keep the AC power and battery connected after battery is fully charged. 2. The charger monitors the battery and tops it off as needed. 3. The Float Charge indicator lights. 4. The display shows charge current when topping off the battery and returns to “FUL” when completed. 5. To view battery voltage, press the Battery Voltage button.

4. Pressing the 2/10/15 AMP button repeatedly advances to standby mode; the unit sounds a beep, displays “000” and stops charging. The battery charger displays the charge current. To view the battery voltage, press BATTERY VOLTAGE button. The charger will sound a beep and display the battery voltage for 3 seconds, then returns to displaying the charge current. 5. The display shows “FUL” when the battery is fully charged. 6. Follow the steps outlined in “Important Safety Instructions” at the front of this manual to disconnect. Automatic Float Charging

WARNING

WARNING

Page 6 of the Vector VEC1089ABD user manual — Alternator Check
Page 6 · click to enlarge
Page 6

Whenever a lead-acid battery begins to discharge, lead sulfate, an insulator, begins to build up on the battery’s internal plates. This reduces the ability of the battery to hold a full charge. When that battery has an immediate charge, most of the lead sulfate is dissolved and the plates are free of this insulation. If a battery remains in a discharged condition over a longer period of time, the lead sulfate changes to a hard crystalline form, making a full charge difficult to achieve. Reconditioning may “save” a sulfated battery. BATTERY RECONDITION MODE should only be used with 10 Amp Hour (Ah) or larger capacity lead-acid batteries. Charge the battery to be treated for 20 minutes, before using RECONDITION Mode. Observe the Digital Display for any codes. This initial charge will check the battery for shorted cells (F01), open cells (F03) or battery too low to accept a charge (F02), and to ensure the battery can take a charge. If code (F03) is displayed, change to the BATTERY RECONDITION MODE. Remove or disconnect the vehicle’s battery when reconditioning. 1. Make sure the charger is in initiation state with a circulating pattern on the display or in charge OFF mode with “000” on the display. If not, press 2/10/15 AMP button repeatedly until “000” shows on the display. 2. Press the Battery Recondition button to start the process. 3. DES appears on the display for 3 seconds, then it changes to three horizontal moving bars. 4. The process takes 24 hours and stops automatically. The display shows “000” when complete.

6. Fill the battery with distilled water according to the manufacturer’s instructions. Since batteries may rapidly bubble while being charged, remember to refill (only with distilled water) after the equalization process is complete and the voltage is back to normal. 7. Follow the steps in the “Charging the Battery” section on page 4 of this manual. 8. Push the Battery Type Selector Switch until “WET” is displayed. (This mode will only work if a WET battery is selected.) 9. Choose the correct charge rate and start charging. You can check the battery voltage by pushing the Battery Voltage button. This will trigger the Battery Voltage indicator button. 10. Push the Equalize button at any time and the battery will automatically begin to equalize in 2 amp limited current. Note that in order to push the recessed button you will need a small pin or ballpoint pen. 11. Every hour, the temperature should be checked by touching the battery. If the battery is hot to the touch, stop the charging and allow the battery to cool. 12. The voltage rises, but does not go over 15.3v to 16.2v (2.55-2.7v per cell) depending on ambient temperature, it will automatically adjust. 13. The “WET” LED flashes while the charger is in equalize mode. 14. The digital readout will show “FUL” when the equalization process is complete. Recondition Mode

The 2/10/15 Amp 12 Volt Smart Battery Charger will automatically adjust the charge rate as the battery becomes charged and stop when the battery is fully charged. Deep cycle batteries may require longer charging time. For estimates of the time it takes to charge a battery, refer to the following table.

APPROXIMATE CHARGING TIMES

If the first alternator check indicates a good alternator and the second indicates the alternator is not good, the problem could stem from: loose fan belts, an intermittent diode failure or possibly bad connections between the battery and alternator and/or ground.

Part 1 No Load (Turn OFF all vehicle’s accessories): The battery must be fully charged before testing the alternator. Run the engine long enough to achieve normal idle speed and verify there is a no-load voltage. 1. Press Alternator Check to start the check. 2. Alternator Good LED will light to indicate the alternator is good, or F07 will display to indicate the alternator voltage is out of typical operation range. 3. Press Alternator Check again to stop the test. Part 2 Under Load (Accessories ON): Next, load the alternator by turning on as many accessories as possible (except for A/C and DEFROST) 1. Press Alternator Check to start the check. 2. Alternator Good LED will light to indicate the alternator is good, or F07 will display to indicate the alternator voltage is out of typical operation range. 3. Press Alternator Check again to stop the test.

Alternator Check

*NR = Not recommended at 2 amps — use a higher charge rate.

at 15 amp rate 1 HRS 2 HRS 2.8 HRS 3.7 HRS

at 10 amp rate 1.4 HRS 2.8 HRS 4.2 HRS 5.5 HRS

at 2 amp rate 7 HRS 14 HRS NR* NR*

Percent of charge in battery 75% 50% 25% 0%

Check only 12 volt systems.

This check may not be accurate for every make, manufacturer and model of vehicle.

F07 may display because someone has added a number of accessory loads on the charging system, thereby increasing current demand from the alternator. MAKE SURE THAT THE ALTERNATOR IS RATED TO SUPPORT THE APPLICATION.

Page 7 of the Vector VEC1089ABD user manual — Display Indications/Common Problems/Possible Solutions
Page 7 · click to enlarge
Page 7
  • Do not use charger if cords or clamps have been damaged in any way — call Technical Support toll-free at (800) 618-5178.
  • There are no user-serviceable parts in this unit.
  • Do not open the unit. In the event of malfunction, it must be returned to manufacturer for professional testing and repair. OPENING THE UNIT WILL VOID THE MANUFACTURER’S WARRANTY.
  • With proper care and minimal maintenance, the 2/10/15 Amp 12 Volt Smart Battery Charger will provide years of dependable service. For maximum performance, manufacturer recommends:
  • After each use, clean the battery charger clamps — be sure to remove any battery fluid that will cause corrosion of the copper clamps.
  • Clean the outside case of the charger with a soft cloth and, if necessary, mild soap solution.
  • Do not allow liquid to enter the charger. Do not operate when charger is wet.
  • Keep the charger cords loosely coiled during storage to prevent damage to the cords. WARNINGS

CARE AND MAINTENANCE

The times shown in the table on page 7 are approximate and refer to a 50 Ah automotive battery. For example, a 50 Ah (12 volt) battery is discharged (50%). How long should it be charged at the 15 amp rate? See the chart above under “50%” and “at 15 amp rate.” In most cases, battery charging times will vary depending on the size, age and condition of the battery. Smaller batteries should be charged at a lower rate (2 amps) and an extra hour added to charge time.

If the battery to be charged is very cold (in temperatures below freezing — 0°C/ 32°F), it cannot accept a high rate of charge. The initial charge rate will be low. The charge rate will increase as the battery warms. Never attempt to charge a frozen battery.

Charging a Very Cold Battery

  • No Functions
  • Check and make sure the charger is plugged into a live 110/120 volt AC outlet.
  • Follow the steps outlined in the Operating Instructions section. F01 — Internal Shorted Cell Battery If the battery being charged has an internal shorted cell, the F01 will show. We recommend taking your battery to a certified automotive service center for evaluation. F02 — Bad Battery Connection or Battery Voltage Too Low to Accept Charge When F02 appears, the most common cause is poor connection to battery.
  • Follow the steps outlined in “Important Safety Instructions” at the front of this manual to disconnect AC cord and clamps, clean battery terminal and reconnect.
  • If the situation persists, we recommend taking your battery to a certified automotive service center for evaluation. F03 — Sulfate or Unchargeable Battery Appears when the battery is highly sulfated and cannot accept normal charge current.
  • Follow the steps in “Recondition Mode” to recondition the battery.
  • Follow the steps in “Equalizing” to equalize the battery.
  • If the situation persists after reconditioning and equalizing, we recommend taking your battery to a certified automotive service center for evaluation. F04 — Overtime Condition Appears when charging time exceeds 18 hours. You may be using a charge current rate too low for a large battery. Select higher charge rate to charge the battery. F05 — Overheated Condition The ventilation grill that prevents the air from flowing in and out of the charger may be blocked.
  • Follow the steps outlined in “Important Safety Instructions” at the front of this manual to disconnect AC cord and clamps, allow the unit to cool for 30 minutes and reconnect.
  • Make sure there is ample ventilation before resuming operation. F06 — Reverse Polarity The connections to the battery’s POSITIVE and NEGATIVE terminals are incorrect. Follow the steps outlined in “Important Safety Instructions” at the front of this manual to disconnect AC cord and clamps and reconnect to battery with correct polarity. F07 — Alternator Voltage Alternator output voltage is out of typical operation range.

Display Indications/Common Problems/Possible Solutions

TROUBLESHOOTING

Page 8 of the Vector VEC1089ABD user manual — CARE AND MAINTENANCE
Page 8 · click to enlarge
Page 8
Page 8 of the Vector VEC1089ABD user manual — CARE AND MAINTENANCE
Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Vector VEC1089ABD

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Vector VEC1089ABD

Be the first to ask — other owners or our team will answer.

Original document

Vector VEC1089ABD manual PDF

8 pages·142 KB·Automobile Battery Charger·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…