DV-40 STEP TOP DIRECT VENT FREESTANDING GAS STOVE (DV-40 STEP)
INSTALLATION, OPERATION, VENTING AND MAINTENANCE INSTRUCTIONS



CONGRATULATIONS! You are now the proud owner of one of the finest gas stoves on the market - the QUADRA-FIRE.
FOR YOUR SAFETY DO NOT store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
This appliance may be installed in an aftermarket permanently located, manufactured (mobile) home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
401 N. Wynne Street Colville, WA 99114
www.aladdinhearth.com aladdin@aladdinhearth.com
Revised 04/19/1998 Part #250-4320 & #842-3220
Revised (8/98)





This stove should be installed only by a qualified installer. It is approved for installation in a bedroom. Bedroom installation in Canada requires that stove be hooked to a thermostat. The stove must be electrically grounded in accordance with local codes, or the latest edition of the National Electric Code. If no local codes exist, this stove should be installed following the current codes:
CAN/CGA-B149.1 Natural Gas Installation Code
CSA-C22.2 No. 3 Canadian Electrical Code ANSI Z223.1 National Fuel Gas Code ANSI NFPA-70 National Electrical Code
Manufactured (mobile) home installation must conform to the manufactured home construction and safety standard (UL307B, Title 24 CFR, Part 3280), or when such a standard is not applicable, the standard for manufactured home installations (ANSI A225.1/NFPA 501A).
The control compartment, burner, and circulating air passageways MUST be kept clean and clear to allow for adequate combustion and proper operation. Provide adequate clearances around air openings and adequate accessibility clearance for service and operation. NEVER obstruct the openings of the stove or the vent termination on the exterior of the building. NEVER vent the stove to other rooms or buildings; this stove must be vented ONLY to the outside. During installation, be sure to maintain minimum clearances to combustibles, as shown on page 14. Always contact your local building department or fire department prior to installing this stove. If required, obtain a permit before installing, and have the completed installation inspected. Failure to do this could jeopardize your homeowner’s insurance.
The area around the stove MUST be kept free from combustible materials, gasoline and other flammable vapors and liquids. This stove is hot during operation, and should be located out of heavy traffic areas and away from furniture and draperies. Clothing or other flammable material should not be placed on or near the stove. Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition. Children should not be left unsupervised in the room when this stove is in operation. Never place anything on or near the heater, the thermostat or remote control can turn the stove on at any time.
If any part of this stove has been under water, DO NOT USE it!! Immediately call a qualified service technician to inspect the stove, and to replace any part of the control system or any gas control which has been under water.
This stove should NOT be modified under any circumstances. Any parts removed for servicing must be replaced before operating this stove. Installation and repair should only be done by a qualified service technician. The stove and its venting system should be inspected and cleaned annually by a qualified service technician. More frequent cleaning may be necessary due to excess lint and dust from carpeting, bedding material, etc. Be sure to turn off gas valve and pilot before cleaning this stove.
Install at least one smoke detector on each floor of your home to ensure your safety. They should be located away from the gas stove and close to the sleeping areas. Follow the smoke detector manufacturer’s placement and installation instructions, and be sure to maintain regularly. Your local fire department may provide assistance in selecting smoke detectors, or contact the Consumer Product Safety Commission, Washington, D.C. 20207. See additional Safety Notices on next page.

SAFETY NOTICES, CONT.
NATURAL GAS PROPANE Manifold pressure 3.5” WC 10.0” WC Minimum inlet gas supply pressure 4.5” WC 11 0” WC Maximum inlet gas supply pressure 7.0” WC 14.0” WC BTU input rating (high) 40,000 BTUH 40,000 BTUH BTU output rating (high)* 34,000 BTUH 34,000 BTUH BTU input rating (low) 26,000 BTUH 27,000 BTUH BTU output rating (low)* 22,100 BTUH 23,000 BTUH Steady State Efficiency* 85% 85%
*Maximum vent, blower off
The Quadra-Fire DV-40 Step is listed to ANSI Z21.88/CSA 2.331998-CAN/CGA 2.17-M91 UL307b by Omni-Test Laboratories, Inc., Beaverton, Oregon.



down to not jar and fracture the logs.

Leg adapter cover · Leveling leg


Pedestal assembly

If desired, a thermostat may be installed to regulate the Quadra-Fire DV-40 Step. It is important to use a thermostat designed for millivolt operation. Do not connect this stove to a thermostat serving any other appliance. Bedroom installation in Canada requires this stove to be hooked to a thermostat.

OPTIONAL THERMOSTATS Manual Thermostat Part #812-2880 Anticipator Setting 1.2
Programable Thermostat Part #811-0520
RECOMMENDED MAXIMUM LEAD LENGTH (TWO WIRE) WHEN USING WALL THERMOSTAT/SWITCH
Wire Size Maximum Length 16 gauge 65 feet 18 gauge 40 feet 20 gauge 25 feet 22 gauge 18 feet
Connect the thermostat wires to the outside terminals labled “TH” and “THTP” located on the valve. Turn off the manual switch, located on the control panel.
A remote control or a wall switch may be wired to the thermostat terminals. Contact your Quadra-Fire dealer or service person for details (see page 45 for part number).
The blower cord is located at the rear of the stove, and needs to be routed to a three-prong outlet with correct polarity. Be sure that the stove is electrically grounded in accordance with local codes, with a current version of CSA C22.2 No. 3 M1988 (in Canada), or in the absence of local codes, with the National Electric Code ANSI/NFPA 70-1987.

Thermostat Connection

There are four types of direct vent system installations approved for use with the DV40 Step. It is very important to maintain a balance between the combustion air intake and the flue gas exhaust venting system. The types of installation are:
Horizontal Termination (Figure 1, Pg. 11) Vertical Termination (Figure 2, Pg. 11)
Into a Class A Metal Chimney (Figure 3, Pg. 11)* Into a Masonry Chimney (Figure 4, Pg. 11)*
When planning your installation, it will be necessary to select the proper length of vent pipe for your particular requirements. The vent graph on page 15 will show the relationship between vertical and horizontal side wall venting, and will help to determine the various vent lengths permitted. It is also important to note the wall thickness. Select the amount of vertical rise desired for “vertical-to-horizontal” type installations. To determine the length of your pipe required for vertical installations, measure the distance from the application flue outlet to the ceiling, the ceiling thickness, the vertical rise in an attic or second story, and allow for sufficient vent height above the roofline. For two-story applications, fire stops are required at each floor level. If an offset is needed in the attic, additional pipe and elbows will be required. When determining the position of the stove, be sure to adhere to minimum clearance to combustibles to the appliance itself. (See page 14.)
When installing this appliance into an existing masonry chimney, it is important to carefully measure the length of flex needed to reach from the appliance outlet to the termination cap. If the flex length is too short, a flex coupler will be needed to attach an additional length of flex liner to make up the difference. If the flex length is too long, the liner could sag below the appliance outlet, which could result in an airflow restriction causing flow reversal or flame lift.
*USA installations only

FOR HORIZONTAL TERMINATIONS USE ONLY DURAVENT PART # 985 OR ALADDIN HEARTH PRODUCTS PART #HHW2 (See * in Figure 1 below). FOR VERTICAL TERMINATIONS USE DURAVENT PART #991.


Simpson Dura-Vent offers a complete line of component parts for installation in both horizontal and vertical applications. Many items are offered in decorative black, as well as a galvanized finish. The galvanized pipe and fittings are used for concealed locations such as attics, or spaces where corrosion is a factor, such as above the roofline. Decorative brass and chrome trim kits are available for both wall thimbles and ceiling support boxes. Snorkel terminations are available for applications which may require a vertical rise on the building exterior. The following components have been approved for use with the Quadra-Fire DV40 Step.
NUMBER DESCRIPTION 705C Flashing (masonry chimney) 902 48” Pipe Length 902B 48” Pipe Length, Black 903 36” Pipe Length 903B 36” Pipe Length, Black 904 24” Pipe Length 904B 24” Pipe Length, Black 906 12” Pipe Length 906B 12” Pipe Length, Black 907B 9” Pipe Length, Black 908B 6” Pipe Length, Black 909B Retro Connector 911B 11” - 14 5/8” Pipe, Adjustable, Black 940 Round Support Box/Wall Thimble 941 Cathedral Ceiling Support Box 943 Flashing, 0/12 to 6/12 Roof Pitch 943S Flashing, 7/12 to 12/12 Roof Pitch 945 45° Elbow 945B 45° Elbow, Black 950 Vinyl Siding Standoff 953 Storm Collar 963 Ceiling Firestop 981 Snorkel Termination (36”) 982 Snorkel Termination (14”) 983 Vertical Termination 985 High Wind Horizontal Termination Cap 985K Top Adapter 986K Top Adapter 987K Top Adapter 988 Wall Strap 990 90° Elbow 990B 90° Elbow, Black 991 High Wind Vertical Termination Cap
The following high wind horizontal termination cap may be obtained from your local dealer:
HHW2 Aladdin High Wind Horizontal Termination Cap

BASIC KITS The standard termination kit (Kit 0970A) includes the following:
990B 1 each 90° Black Elbow 940 1 each Round Ceiling Support/Wall Thimble 985 1 each High Wind Horizontal Termination Cap
The standard termination kit (Kit 0971HW) includes the following:
990B 1 each 90° Black Elbow 940 1 each Round Ceiling Support/Wall Thimble 985 1 each High Wind Horizontal Termination Cap 904B 1 each 24” Black Pipe 911B 1 each 11” - 14 5/8” Black Adjustable Pipe
The vertical termination Kit (Kit 973) includes the following:
943 1 each Flashing 0/12 - 6/12 953 1 each Storm Collar 991 1 each High Wind Vertical Termination Cap

Minimum clearances to combustible materials from stove body:
A Left & Right of Stove (One Wall) 9” (225mm) B Back wall (to Pipe) 8” (200mm) C Top of unit (from Stove Top) 24” (600mm) D Corner clearance* 1” (25mm) E Alcove (Each Side) 12” (300mm) (Max. Depth) 36” (915mm) * In corner installations one inch is the clearance to combustibles. However, on the valve side of stove, 6 inches may be required to allow safe access to controls.



HEARTH REQUIREMENTS: The floor area beneath the stove must be stable, level and strong enough to support the stove without a tipping hazard. The Leg Model requires a non-combustible hearth pad. The Pedestal Model does not require a non-combustible hearth pad when placed over wood flooring, ceramic tile, brick hearths, or high pressure laminate flooring applied directly over the sub-flooring material. Neither model may be installed over carpet or combustible tile (vinyl tile) without a non-combustible panel extending the full width and depth of the appliance.

Example 1: If the vertical dimension from the top of the stove to the center of the 90° elbow is 7’ (2.13m),
the horizontal run to the outer wall flange must not exceed 9’ 9” (2.97m).
Example 2: If the vertical dimension from the top of the stove is 21’ (6.4m), the horizontal run to the outer
wall flange must not exceed 7’ 3” (2.21m).


PLEASE NOTE: In order to comply with applicable codes and product warranties, only Simpson Dura- Vent venting components may be used. DO NOT USE FIELD-FABRICATED VENTING COMPONENTS.
The Quadra-Fire DV40 Step is approved to be vented either through the side wall or vertically through the roof. You may vent through a Class A or masonry chimney if a Simpson Dura-Vent adapter is used (for USA installations only). Only Simpson Dura-Vent components labeled and listed in this section may be used.
Read all these instructions carefully before starting the installation. Failure to follow instructions may create a fire or other safety hazard, and will void the warranty. Be sure to follow these installation instructions for venting and clearance to combustible requirements, which may vary from one installation to another. Do not extend the venting system in excess of the distance prescribed in these manufacturer’s installation instructions.
The Quadra-Fire DV40 Step is an engineered product that has been designed and tested. The warranty will be voided, and serious fire, health, or other safety hazards may result from any of the following actions: installation of any damaged venting component, unauthorized modification of the venting system, installation of any component part not approved by Aladdin Hearth Products, or installation other than as instructed by these instructions. Consult your local building codes before beginning this installation.
Any vertical termination greater than 10’ (ten feet) needs a restrictor strap placed in the top of the 4” (four inch) exhaust outlet of the appliance. Any horizontal termination with greater than 10’ (ten feet) of vertical rise requires this same restrictor strap. (See Pg. 45, Restrictor strap part #842-3330).
WARNING: Always maintain the required clearances (air space) to nearby combustibles to avoid creating a fire hazard. Do not fill air space with insulation. Minimum clearance between vent pipes and combustible surfaces is 1” (25mm), except where stated otherwise. Be sure to check the vent termination clearance requirements from decks, windows, soffits, gas regulators, air supply inlets and public walkways, as specified in these installation instructions and local building codes. (Refer to page 18 for horizontal installation instructions.)
The gas stove and vent system must be vented directly to the outside of the building, and never be attached to a chimney serving a separate solid fuel or gas-burning appliance. This direct vent gas stove must use its own separate vent system. Common vent systems are prohibited.
Wear gloves and safety glasses for protection when installing this stove. Exercise extreme electrical caution when using ladders or on rooftops. Be aware of electrical wiring locations in walls and ceilings.

A Clearance to non-mechanical air supply inlet to building, or the combustion air inlet to any other stove - 12” (305mm) minimum B Clearance above paved sidewalk or a paved driveway located on public property - 84” (2.1m) minimum D Not to be installed above a meter/regulator assembly within 36” (914mm) horizontally from the centerline of the regulator E Clearance to service regulator vent outlet - 72” (1.8m) minimum F Clearance above grades, veranda, porch, deck or balcony - 12” (305mm) minimum G Clearance to window or door that may be opened - 12” (305mm) minimum on top and sides and 24” below H Clearance to permanently closed window - 12” (305mm) recommended to prevent condensation on window I Clearance under veranda, porch, deck or balcony - 18” (457mm) minimum if fully open on a minimum two sides beneath the floor J Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 24” (610mm) from the centerline of the terminal - 18” (457mm) minimum K Clearance to unventilated soffit - 12” (305mm) minimum L Clearance to inside corner - 9” (229mm) minimum M Clearance to a mechanical air supply inlet - 72” (1.8m) minimum N Clearance to outside corner - 6” (152mm) minimum
A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwelling and serves both dwellings (not pictured).
A vent shall not terminate within 36" (914mm) of the property line (not pictured).
For USA installations follow current National Fuel Gas Code ANSI Z223.1.


Twist-lock procedure: Four indentations, located on the female ends of pipes and fittings, are designed to slide straight onto the male ends of adjacent pipes and fittings by orienting the four pipe indentations so they match and slide into the four entry slots on the male ends (Figure 5). Push the pipe sections completely together, then twist-lock one section clockwise approximately one-quarter turn, until the two sections are fully locked. The female locking lugs will not be visible from the outside, on the pipe or fittings. They may be located by examining the inside of the female ends. There is a 1/4” rise per foot minimum on horizontal run.

FIG. 5
MALE LOCKING LUGS

Step 3. With the adapter and pipe attached to the stove, slide the stove into its correct location, maintaining minimum clearance to combustibles, and mark the wall for a 10” x 10” (254mm x 254mm) square hole. The center of the square hole should line up with the centerline of the horizontal pipe, as shown in Figure 6. Cut and frame the hole in the exterior wall where the vent will be terminated. If the wall being penetrated is constructed of noncombustible material, i.e. masonry block or concrete, a 7” (178mm) diameter hole is acceptable.
(1) The horizontal run of vent must be level, or have a ¼” (6mm) rise for every 1’ (305mm) of run towards the termination. Never allow the vent to run downward. This could cause high temperatures and may present the possibility of a fire.
(2) The location of the horizontal vent termination on an exterior wall must meet all local and national building codes, and must not be easily blocked or obstructed.
(3) For installations requiring a vertical rise on the exterior of the building, 14” (356mm) and 36” (914mm) tall snorkel terminations are available. Follow the same installation procedures as used for standard horizontal terminations. If the snorkel termination must be installed below grade (i.e. basement application), proper drainage must be provided to prevent water from entering the snorkel termination. Do not backfill around snorkel termination.


(2) For buildings with vinyl siding, a vinyl siding standoff (Simpson Dura-Vent part 950), should be installed between the vent cap and the exterior wall (Figure 8). Attach the vinyl siding standoff to the horizontal vent termination. Remove vinyl siding under termination cap. The vinyl siding standoff prevents excessive heat from possibly melting the vinyl siding material. Vent terminal shall not be recessed into a wall or siding.


FIG. 7
or HHW2
Remove siding from
beneath Standoff

Step 6. Slide the stove and vent assembly towards the wall, carefully inserting the vent pipe into the vent cap assembly. It is important that the vent pipe extend into the vent cap sufficient distance so as to result in a minimum pipe overlap of 1¼” (32mm). Secure the connection between the vent pipe and the vent cap by attaching the two sheet metal strips extending from the vent cap assembly into the outer wall of the vent pipe. Use the two sheet metal screws provided to connect the strips to the pipe section. Bend any remaining portion of the sheet metal strip back towards the vent cap, so it will be concealed by the decorative wall thimble cover (Figure 9).


ddesireddesired.

USING GS SERIES PIPE Step 1. Check the installation instructions for required 2 inch clearances (air space) to combustibles when passing through ceilings, walls, roofs, enclosures, attic rafters, or other nearby combustible surfaces. (See page 24, FIG. 16) Do not pack air space with insulation. Check the instructions below for maximum vertical rise of the venting system, and any maximum horizontal offset limitations (Figure 11). All offsets fall within the set parameters of the vent graph located on page 15.

installation does not decrease maximum vertical rise (as specified by Vent graph, pg. 15).
Step 2. Set the gas stove in its desired location. Drop a plumb bob down from the ceiling to the position of the stove flue exit, and mark the location where the vent will penetrate the ceiling. Drill a small hole at this point. Next, drop a plumb bob from the roof to the hole previously drilled in the ceiling, and mark the spot where the vent will penetrate the roof. Determine if ceiling joists, roof rafters, or other framing will obstruct the venting system. You may wish to relocate the stove, or to offset, as shown in Figure 12, to avoid cutting loadbearing members.


Placement of Restrictor Strap, Part #842-3330
shaft.
FIG. 13

USING GS SERIES PIPE (CONT.) Step 4. Assemble the desired lengths of GS pipe and elbows necessary to reach from the stove up through the round support box. Insure that all pipe and elbow connections are in their fully twist- locked position. Be sure to seal the outer pipe with appropriate sealant (high temperature silicone).
Step 5. Cut a hole in the roof centered on the small drill hole placed in the roof in step 2. The hole should be of sufficient size to meet the minimum requirements for clearance to combustibles, as specified. Continue to assemble lengths of pipe and elbows necessary to reach from the ceiling support box up through the roof line. Galvanized pipe and elbows may be utilized in the attic, as well as above the roofline. The galvanized finish is desirable above the roofline, due to its higher corrosion resistance.
(1) If an offset is necessary in the attic to avoid obstructions, it is important to support the vent pipe every 3’ (914mm) to avoid excessive stress on the elbows, and possible separation. Wall straps are available for this purpose (Figure 12).
(2) Whenever possible, use 45° elbows, instead of 90° elbows. The 45° elbow offers less restriction to the flow of flue gases and intake air.


USING GS SERIES PIPE (CONT.) Step 7. Continue to assemble pipe sections until the height of the vent cap (H) (Figure 15) meets the minimum code requirements described in code requirements as outlined in the current CAN/ CGA-Bl49 Installation Codes (in Canada), the National Fuel Gas Code NFPA 54/ANSI Z223.1 (in USA), or local codes. Note that for steep roof pitches, the vent height must be increased. In high wind conditions, nearby trees adjoining rooflines, steep pitched roofs, and other similar factors can result in poor draft, or down drafting. In these cases increasing the vent height may solve this problem.
(1) For multi-story vertical installations, a ceiling firestop (SDV part #963) is required at the second floor, and any subsequent floors (Figure 16). The opening should be framed to 10” x 10” (254mm x 254mm) inside dimensions, in the same manner as shown in Figure 13.
(2) Any occupied areas above the first floor, including closets and storage spaces, which the vertical vent passed through must be enclosed. The enclosure may be framed and sheetrocked with standard construction materials; however, refer to these installation instructions for the minimum allowable clearance between the outside of the vent pipe and the combustible surfaces of the enclosure. Do not fill any of the required air space with insulation.



CATHEDRAL CEILING INSTALLATION Step 1. Follow installation Steps 1 and 2 under vertical termination section.


through 8 for vertical terminations.

INSTALLATION INTO A CLASS A METAL CHIMNEY NOTE: Have the existing installation inspected by a qualified chimney sweep or professional installer
prior to converting to direct vent. The existing chimney system must be in serviceable condition and functionally sound and clean.




INSTALLATION INTO AN EXISTING MASONRY CHIMNEY Step 1. Before cutting any holes, assemble the desired sections of direct vent pipe to determine the center of the masonry penetration.

Step 2. Once the center point of the penetration has been determined, cut a 6” (152mm) diameter hole in the masonry. If the hole is too large, the retro connector might not mount properly; if the hole is too small, the appliance might starve for intake air. If there is a frame wall in front of the masonry wall, cut and frame a 10” (254mm) square opening in the wall (centered around the 6” [152mm] masonry opening). If there is sheet rock only (no studs) in front of the masonry the 10” (254mm) opening is still needed, but does not need to be framed. This allows the retro connector to mount directly on the masonry and provide the correct clearances to combustibles (see Figure 22).






retro connector and secure with masonry bolts (Figure 27). If you have a framed wall in front of the masonry, use wood screws to mount wall thimble cover to framed wall, over retro connector and 10” (254mm) square framed opening (Figure 22). If needed, add a section of direct vent pipe to the retro connector in order to extend through the opening in the wall thimble cover.
the retro connector may be completed with sections of direct vent pipe.


Gas line connection can be made near the lower rear of the stove (3/8” gas hookup). You must supply a shutoff valve installed in a visible location within 3’ (914 mm) of the stove.
Before hooking up the stove to the gas supply, be sure that the stove you are installing is designed for the type of gas being supplied to it. There is a serial number and listing label on the rear of the stove that will indicate which type of gas it is designed to utilize.
There is a 3/8” gas hookup located on the valve. We recommend connecting the stove with an approved flex gas line, as shown below. If flex gas lines are not approved in your area, you can connect a hard pipe to the gas hookup.
After running new gas line or if a gas line has been disconnected, purging of the gas line may be necessary. To purge gas line, open the inlet pressure tap and allow gas to flow through while carefully monitoring for the odor of either natural gas or propane. As soon as you smell the gas, discontinue purging the line. Insure that the room has plenty of ventilation and that no sparks or open flames are near the end of the gas line during the purging process. Do not try to ignite the stove until any and all gas accumulation has been cleared from the room.


CAUTION IN SOME AREAS, GAS LINE PRESSURE MAY BE MORE THAN 1/2 PSIG (14”WC). IF YOU BELIEVE THAT THIS MIGHT BE THE CASE IN YOUR LOCALITY, CONTACT YOUR GAS SUPPLIER OR LOCAL UTILITY COMPANY. LINE PRESSURE GREATER THAN 1/2 PSIG WILL DAMAGE THE STOVE VALVE. YOU MUST INSTALL A REGULATOR UPSTREAM FROM THE STOVE IF LINE PRESSURE IS GREATER THAN 1/2 PSIG.

In Canada, this unit is approved from 0 to 4500 feet above sea level. Installation of this stove at altitudes above 4500 feet is subject to field test of the individual installation and approval by the local authority having jurisdiction.
In the United States, input ratings of this unit are based on sea level operation, and shall not be changed for operation at elevations up to 2000 feet. For operation at elevations above 2000 feet, this stove shall be reduced at the rate of 4% for each 1000 feet above sea level.
Exception: As permitted by the authority having jurisdiction.
To adjust stove for operation above 2000 feet the burner orifices may need to be changed. The orifices are located beneath the log set so it is necessary to first remove the logs. To do so please refer to the following detailed instructions to achieve optimum performance of your stove.
appliance installer.
BEFORE PROCEEDING.
1. Remove the right top log bracket using a Phillips screwdriver (Screws are accessed through rectangular hole in bracket.) See FIG. 4, pg. 37 (Peg in right log bracket.) 2. Remove the right and left side log retaining brackets (one per side). 3. Carefully lift logs vertically off alignment pegs and place in a safe area out of the way of traffic. 4. Use a Phillips screwdriver to remove the top plate of center burner pan located in the middle of the “U” shaped burner. 5. Remove the top plate of left burner pan. 6. The right burner can now be lifted by prying up using a slotted screwdriver to snap burner out of pinch retainer. After burner is lifted, shift to the right to slide off the orifice receiver. 7. The “U” burner is removed using the same technique. Slide the burner out of the shutter ring. You now have access to the orifices. 8. Using a 3/8” socket, remove orifice spuds and replace with correct high altitude orifices:
Stock Orifices Natural Gas Propane Front 39 54 Rear 49 56

The installation of this conversion kit must only be undertaken by a qualified and certified
gas appliance installer.
1. Turn control knob to the OFF position and shut off the gas supply to the valve. 2. Using a Torx T20, or slotted screwdriver, remove the three pressure regulator mounting screws (A), pressure regulator tower (B), and diaphragm (C). (You may wish to retain these items for converting back to original gas if necessary.) 3. Insure that the rubber gasket (D) is properly positioned and install the new HI/LO pressure regulator assembly to the valve using the new screws (E) supplied with the kit. Tighten screws securely. (Reference torque = 25 in/lb) 4. Install the enclosed identification label (F) to the valve body where it can be seen.


Valve Regulator Tower

5. Remove the right top log bracket using a Phillips screwdriver (Screws are accessed through rectangular hole in bracket.) See Fig. 4, Pg. 37 (Labeled “Peg in right log bracket”) 6. Remove the right and left side log retaining brackets (one per side). (Top of log and firebox side.) 7. Carefully lift logs vertically off alignment pegs and place in a safe area out of the way of traffic. 8. Use a Phillips screwdriver to remove the top plate of the center burner pan located in the middle of the “U” shaped burner. 9. Remove the top plate of left burner pan. 10. The right burner can now be lifted by prying it up using a slotted screwdriver to snap the burner out of pinch retainer. After burner is lifted, shift to the right to slide it off the orifice receiver. 11. The “U” burner is removed using the same technique. Slide the burner out of the shutter ring. You now have access to the orifices. 12. Using a 3/8” socket, remove orifice spuds and replace with the orifices in question.
Natural Gas Propane Front 39 54 Rear 49 56
Burner Orifice Replacement




Log replacement

Lighting and pressure testing
INSTALLER NOTICE: These instructions must be left with appliance.
performance, and aesthetics of this appliance.
Follow each step accurately.
3. Place center log, #23, on positioning pegs in center burner pan with the black char end facing forward. See FIGURE 1 4. Empty nugget bags on a paper towel or other discardable surface, and place nuggets randomly on top of the “U” burner. Cover entire burner evenly with a single layer of nuggets. See FIGURE 2 5. Place left top log, #22, on peg of left main log and peg of center log. See FIGURE 3 6. Place end of right top log, #24, on top of left top log notch, and front of log on the peg of right log bracket. See FIGURE 4


PLACE PEG HOLES IN LOG #23 OVER PEGS IN CENTER BURNER
PAN.
If damage has occurred to right or left base log, and replacement is necessary, removal is illustrated in conversion instruction steps 5-7.

BACKSIDE OF THIS PLATE.
NUGGETS TO BLOCK AIR GAP
BETWEEN BURNER PAN AND
BURNER.

LOG #22
PEG HOLES IN LEFT TOP LOG
PEG IN CENTER LOG
PEG IN LEFT BASE LOG


RIGHT TOP LOG #24.
PEG IN RIGHT LOG BRACKET
NOTCH FOR RIGHT TOP LOG

Light appliance with door open to insure there is no hesitation or delay of flame transfer through nugget bed. If ignition is noisy or delayed momentarily, the nuggets in that area may need to be rearranged. Close door and continue with flame adjustment. See “Shutter Adjustment” on following page.

Before first firing the stove, read the owner’s manual to familiarize yourself with the stove’s features, controls, and cautions for operation. Remove all labels from glass before operating this stove for the first time.
Plug power cord into a properly installed outlet for blower operation.
During your first fire in the stove, you may notice an odor and steam coming from the stove. This is normal, it is the high temperature paint finishing the curing process. Open doors and windows in your home or structure for ventilation. 1. Follow the procedure under lighting instructions on page 39 of this manual (also located on the back of the stove). 2. After a flame has been established for 2 minutes, turn off the burner switch located at the top right of appliance. Turn this switch on and off while watching the flame area of stove to verify correct lighting through the nugget bed. If ignition is noisy or is delayed momentarily, the nuggets in that area may need to be rearranged. 3. Allow flame to burn for at least 20 minutes or until orange halo in the flame disapears. It is recommended that the stove be cycled by turning stove on for twenty minutes, and then turned off to cool for five minutes. Then turn the stove back on and burn until the steam and/or odor are no longer present.
If odor persists, turn the gas supply to the stove off and call your local dealer or authorized service agent.
The blower system has an on/off thermally operated snap disc that will turn the blower on automatically when the proper temperature is reached and turns the blower off when the temperature cools. You may also turn the blower on or off manually and adjust the volume. It will still be necessary for the snap disc to be up to temp. The blower controls are located on a box at the right rear top of stove.
SHUTTER ADJUSTMENT 1. Remove left side panel prior to lighting stove. 2. Light stove and let unit burn for approximately 20 minutes to allow logs to cure. While logs are curing you may notice a bright orange flame, this is normal. When this flame turns to yellow or disappears, the shutter adjustment can take place. 3. The shutter is pre-set at the factory so shutter adjustment may not be necessary. If flame height adjustment is required, turn the adjustment screw clockwise to close shutter and obtain a yellow flame. For a blue flame with more glow, turn the adjustment screw counter-clockwise to open the shutter. 4. Wait five minutes to allow for flame to settle. If the flame is not satisfactory, repeat the procedure in step #3. 5. When the desired flame is acquired, replace the side panel.



This appliance must be disconnected from the gas supply piping system if any testing is done to the system that exceeds the test pressure of 1/2 PSIG. If the test pressure is less than or equal to 1/2 PSIG, then this appliance must be isolated from the piping system by closing its individual shutoff valve. The gas valve is supplied with pressure test ports for checking input and output pressures. These are located just above the on/off knob and can be found at the rear of the appliance. Pressure can be checked by turning the captured screw counterclockwise two or three turns and then placing the manometer tubing over the test port. The inlet pressure should be checked with the burner lit. BE SURE TO CLOSE CAPTURED SCREWS AFTER TESTING BY TURNING THEM CLOCKWISE. DO NOT OVERTIGHTEN SCREWS.

Inlet and Manifold Pressures can only be taken with the burner lit.

TEST VA LV E
O U TPU T SID E
TEST VA LV E
(Inlet Pressure) · (Manifold Pressure)

CLEANING AND INSPECTION OF VENTING SYSTEM At least once yearly, preferably before the heating season, have the insert and venting system cleaned and inspected by a qualified service person. This will insure proper and safe operation throughout the year.
CLEANING THE BURNER TUBES 1. Turn off pilot light. 2. Loosen set screw in casting by latch and open door. 3. Remove logs and glowing charcoals. (See Burner orifice Replacement, Pg. 33) 4. Vacuum burner compartment, especially around orifice and primary air openings. 5. Relight pilot. Check to insure flames are touching millivolt generator (see diagram at right). 6. Reinstall logs. See page 33, 35-37 for log installation instructions. 7. Close front door and lock it in place with the allen screw. 8. Recheck pilot and main burner to insure they are operating correctly.
MILLIVOLT GENERATOR

GLASS CLEANING
WARNING: You must clean all the fingerprints and oils from the gold surface before firing the appliance for the first time. Use a glass cleaner or vinegar and a towel to remove the oils. If not cleaned properly before lighting your first fire, the oils can cause permanent markings on the gold plating. After the gold plating is cured, the oils will not affect the finish and little maintenance is required, just wipe clean as needed.
OR GOLD SURFACES.

Cleaning is recommended at least once yearly or as needed.
For Replacement:
Follow instructions above for removal of blower.
Re-install new blower:

Take care not to lose the rubber on blower compartment fingers. If rubber is removed vibration can occur during blower operation.





These may be ordered through your Quadra-Fire dealer.
812-2880 Thermostat, manual 811-0520 Thermostat, programable 844-0100 Thermostatic Remote Control
842-3200 Baffle 842-3230 Black door with gold trim ring 842-3210 Blower assembly, 160 cfm 842-0380 Blower cord, 6 foot 832-2970 Blower snap disc, ceramic, 125 degree 841-0670 DV40 Step Top log set 842-3270 L burner 842-3190 LP conversion kit 842-0380 LP Orifices Front 842-1100 LP Orifices Rear 842-0250 Millivolt generator (thermopile) 842-2500 NG conversion kit 842-3290 NG Orifices Front 842-3300 NG Orifices Rear 841-0370 Nuggets, charred 842-3220 Owner’s Manual 842-0360 Piezo igniter 842-2450 Pilot assembly, NG 842-3420 Pilot Orifice, NG 842-3430 Pilot Orifice, LP 842-3330 Restrictor Strap 842-1660 Rocker switch, high temperature 842-3250 Speed control with knob 842-1580 Thermocouple 842-3280 U burner 842-3240 Wire harness


NOTE: It is important to understand that the flame and glow in this appliance was designed to resemble a matured wood flame. The amount of charcoal nuggets and glowing ember limit the amount of flame height attainable. This appliance will not have the typical tall yellow gas unit flames. (Avg. flame height 3- 5”). This stove will take 20-30 minutes for the flame to establish itself.
Low Flames (correct flame height is 3-5”)
Twenty to thirty minutes of burning is required for this unit to equalize temperature therefore attaining correct flame height and color. If flame after this time is inadequate:

Burner shutter adjustment screw.

Flame Troubleshooting, cont.

damper shaft.
3. If vented vertically with a horizontal run included; determine if the rise to run is close to the venting graft maximum, i.e. you are using the maximum horizontal for the amount of vertical. If the vertical rise is much greater than the horizontal run the restrictor strap may be installed to slow combustion air. If this method is used, light the stove for the first time and watch for flame lift (blue flame 1-30 seconds lifting off burner and hovering in the middle of the firebox.) If this is visible immediately shut the gas valve off and remove the restrictor strap. Flame height can now be further adjusted by using shutter adjustment previously described in step 1.

A. Pilot won’t light 1. Make sure valve setting is in the pilot position. 2. Check for spark at igniter. a. If no spark: 1. Check the wiring between the piezo and the igniter. Wire may be looped and be sparking to stove body. If so, move wiring. Check tightness of piezo mounting nut. If this does not remedy the problem you may have a faulty piezo or cracked ceramic on the electrode. 2. Call your Quadra-Fire dealer. b. If there is a spark: 1. Try to light the pilot with a match (use caution when doing this.) First open door and smell for gas, then toss lit match below pilot. Watch for blue flame. The flame should either light or flutter. a. If the flame flutters but does not light the pilot, there is probably air in the line. Hold match or lighter flame to pilot hood, then bleed the line until gas comes through. b. If the match flame does not flutter, make sure the gas is turned on and be sure you are pushing the knob in all the way. If this still doesn’t help, you may be dealing with a bad valve, a blocked pilot orifice, or a kinked pilot line. 3. Call your dealer or authorized service person. B. Pilot goes out when knob is released 1. Wait five minutes and try again. If the pilot still goes out, try again and hold the knob in longer. 2. If the problem persists, look to see that the pilot flame is contacting thermopile and thermocouple, see picture on following page. If flame is not contacting thermopile and thermocouple, pilot adjustment screw can be turned counter clockwise to increase pilot flame. If flames do not increase, chances are the inlet pressure is low. The inlet pressure cannot be checked accurately unless burner is lit. Turn off gas supply valve and disconnect from appliance. Quickly turn on and listen for ample gas supply. If volume is good, call your dealer or authorized service person. C. Pilot lights but burner won’t ignite 1. Make sure the knob is turned to the “on” position. 2. Turn the thermostat up. Make sure burner switch is in the OFF position. 3. If there is no thermostat, flip the manual switch on the control panel of the stove. If the burner does not light, short out the thermostat screws on the face of valve marked TH and TPTH. If the burner lights, you may have a problem in the wiring of the stove, and it should be checked. 4. Check the thermostat and thermopile connections at the valve, and tighten or reconnect if needed. Check thermopile connections for grounding. Check that thermopile lead nut is snug. (Do not over tighten.) 5. If the burner still will not ignite, you may have a bad valve; call your dealer or authorized service person.
Check the pilot and burner flames periodically. When properly adjusted, the pilot flame should look like the illustration on the following page. Call your dealer or authorized service person to have the pilot properly adjusted.


PILOT ASSEMBLY SHOWING FLAME PROPERLY ADJUSTED.
Thermopile · Thermocouple

GAS STOVE LIMITED LIFETIME WARRANTY Aladdin Hearth Products, warrants this gas heating appliance to the original purchaser for the lifetime of the appliance, to be free from defects in material and workmanship. This warranty gives you specific legal rights; you may have other rights which may vary from state to state.
This limited Lifetime Warranty covers items such as but not limited to combustion chambers, burners, gas logs, and gold plating.
All parts to be replaced must be returned to an authorized Aladdin Hearth Products dealer at purchaser’s expense for inspection and approval by Aladdin Hearth Products prior to repair or replacement. No repair or replacement costs will be honored without approval of Aladdin Hearth Products.
This new Quadra-Fire product must be installed by a competent, authorized service contractor. It must be installed and operated at all times in accordance with the Installation, Operation and Maintenance Instructions furnished with this product, as well as any applicable local and national codes. Any alteration, willful abuse, accident, or misuse of the product shall void this warranty.
Any installation, construction, transportation, or other related costs or expenses arising from defective part(s), repair, replacement, etc., will not be covered by this warranty, nor will Aladdin Hearth Products assume responsibility for them. Further, Aladdin Hearth Products will not be responsible for any incidental, indirect, or consequential damages, except as provided by law.
All electrical components such as but not limited to blowers, wiring, thermodisc switches and gas valves are covered by Aladdin’s one year warranty program.
Aladdin Hearth Products will not be responsible for any alteration to the unit which causes sooting that results in damage to the interior of the building in which this appliance is installed.
This warranty is void if the stove has been operated in atmospheres contaminated by chlorine, fluorine, or other damaging chemicals, or the stove is subjected to prolonged periods of dampness or condensation.
This limited Lifetime Warranty does not extend to or include paint or ceramic insulating materials. It does not cover installation or operational related problems such as overfiring, or negative air pressures caused by mechanical systems such as furnaces, fans, clothes dryers, etc.
This limited Lifetime Warranty does not apply to hearth components or other accessories used in conjunction with the installation of this product not manufactured by Aladdin Hearth Products.
This limited Lifetime Warranty is effective on all gas stoves sold after September 1, 1996, and supersedes any and all warranties currently in existence.
This warranty is not valid unless the warranty registration card has been properly completed in full and returned within 10 days from the date of purchase to Aladdin Hearth Products, 401 North Wynne Street, Colville, WA 99114- 2153. Proof of purchase is required to secure warranty.
FOR YOUR RECORDS Date of Purchase Model #
Authorized Dealer Serial #
Copyright Aladdin Hearth Products, September 1997 (842-3220)